Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
1.
Dent Mater ; 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38944559

RESUMO

OBJECTIVE: To assess the influence of calcination process on the properties of minimally processed recycled 3Y-TZP, and to compare it with its commercial counterpart. METHODS: Non-milled 3Y-TZP waste was collected, fragmented and ball-milled to a granulometric < 5 µm. Half of the recycled powder was calcined at 900 °C. Recycled 3Y-TZP disks were uniaxially pressed and sintered to create two recycled groups: 1) Calcined and 2) Non-calcined to be compared with a commercial CAD/CAM milled 3Y-TZP. The microstructure of experimental groups was assessed through density (n = 6), scanning electron microscopy (n = 3) and energy-dispersive X-ray spectroscopy (n = 3); and the crystalline content was evaluated through X-ray diffraction (XRD) (n = 3). Optical and mechanical properties were investigated through reflectance tests (n = 10), and Vickers hardness, fracture toughness (n = 5), and biaxial flexural strength tests (n = 16), respectively. Fractographic analysis was performed to identify fracture origin and crack propagation. Statistical analyses were performed through ANOVA followed by Tukey´s test, and by Weibull statistics. RESULTS: Particle size distribution of recycled powder revealed an average diameter of ∼1.60 µm. The relative density of all experimental groups was > 98.15 % and XRD analysis exhibited a predominance of tetragonal-phase in both recycled groups, which were similar to the crystallographic pattern of the control group. Cross-section micrographs presented flaws on the non-calcined group, and a more homogeneous microstructure for the calcined and commercial groups. Commercial samples showed lower contrast-ratio and higher translucency-parameter than the recycled groups, where non-calcined presented higher translucency-parameter and lower contrast-ratio than its calcined counterpart. The commercial group presented higher fracture toughness and characteristic strength than the recycled groups. Moreover, the calcined group exhibited higher hardness, characteristic strength, and probability of survival at higher loads than the non-calcined group. Fractographic analysis depicted the presence of microstructural flaws in the non-calcined group, which may have acted as stress-raisers and led to failures at lower flexural strengths values. SIGNIFICANCE: The calcination process improved the microstructure, optical, and mechanical properties of the recycled 3Y-TZP.

2.
ACS Appl Mater Interfaces ; 16(26): 34057-34068, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38910292

RESUMO

The current longevity of dental resins intraorally is limited by susceptibility to acidic attacks from bacterial metabolic byproducts and vulnerability to enzymatic or hydrolytic degradation. Here, we demonstrate synthesizing an ionic liquid-based antibiofilm silane effective against Streptococcus mutans, a major caries pathogen. Furthermore, we incorporate this silane into dental resins, creating antibiofilm- and degradation-resistant materials applicable across resin types. FTIR, UV-vis, and NMR spectroscopy confirmed the synthesis of the expected ionic liquid-based silane. The characterization of SiO2 after the silanization indicated the presence of the silane and how it interacted with the oxide. All groups achieved a degree of conversion similar to that found for commercial resin composites immediately and after two months of storage in water. The minimum of 2.5 wt % of silane led to lower softening in solvent than the control group (GCTRL) (p < 0.05). While the flexural strength indicated a lower value from 1 wt % of silane compared to GCTRL (p < 0.05), the ultimate tensile strength did not indicate differences among groups (p > 0.05). There was no difference within groups between the immediate and long-term tests of flexural strength (p > 0.05) or ultimate tensile strength (p > 0.05). The addition of at least 5 wt % of silane reduced the viability of S. mutans compared to GCTRL (p < 0.05). The fluorescence microscopy analysis suggested that the higher the silane concentration, the higher the amount of bacteria with membrane defects. There was no difference among groups in the cytotoxicity test (p > 0.05). Therefore, the developed dental resins displayed biocompatibility, proper degree of conversion, improved resistance against softening in solvent, and stability after 6 months of storage in water. This material could be further developed to produce polymeric antimicrobial layers for different surfaces, supporting various potential avenues in developing novel biomaterials with enhanced therapeutic characteristics using ionic liquid-based materials.


Assuntos
Líquidos Iônicos , Nanopartículas , Silanos , Dióxido de Silício , Streptococcus mutans , Silanos/química , Silanos/farmacologia , Streptococcus mutans/efeitos dos fármacos , Dióxido de Silício/química , Dióxido de Silício/farmacologia , Líquidos Iônicos/química , Líquidos Iônicos/farmacologia , Nanopartículas/química , Antibacterianos/farmacologia , Antibacterianos/química , Animais , Resinas Compostas/química , Resinas Compostas/farmacologia , Camundongos , Biofilmes/efeitos dos fármacos , Resistência à Tração
3.
Dent Traumatol ; 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38794914

RESUMO

BACKGROUND/AIM: 3D printing processes can be used to manufacture custom-made mouthguards for sports activities. Few studies have compared the impact performance of industrial-created mouthguards with that of custom-made mouthguards manufactured by thermoforming or 3D printing. The objective of this in vitro study was to compare the shock absorption capacities of custom-made mouthguards manufactured by 3D printing with industrial mouthguards and thermoformed ethylene vinyl acetate (EVA) mouthguards. MATERIALS AND METHODS: For each type of mouthguard, eight samples were produced. 3D-printed mouthguards were manufactured using digital light processing technology. Each mouthguard was subjected to an impact performance test defined by the standard AFNOR XP S72-427, which evaluate maximum deceleration and force transmitted during impact. The thickness of each mouthguard before and after a series of five impacts was measured at the impacted inter-incisal area. RESULTS: The mean maximum decelerations during impact ranged from 129 to 189 g for industrial mouthguards, 287 to 425 g for thermoformed EVA mouthguards, and 277 to 302 g for 3D-printed mouthguards. The mean reduction in mouthguard thickness at the impact zone after five tests was 1.2 mm for industrial mouthguards, 0.6 mm for 3D-printed mouthguards, and 2.2 mm for thermoformed EVA mouthguards. CONCLUSIONS: Custom-made 3D printed mouthguards showed slightly better shock absorption ability than thermoformed mouthguards with respect to the indicator proposed in XP S72-427. They seemed to combine the practical advantages of thermoformed mouthguards in sports with better shock absorption capacity and lower cost. Furthermore, they had the least thickness variation during the test, and their shock absorption capacity was the least affected by repeated mechanical tests. Other types of 3D-printing resin materials that will become available must continue to be tested for shock absorption to provide the best protection to users at low cost.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38780791

RESUMO

PURPOSE: We aim to compare interfragmentary compression with the position osteosynthesis in the fixation of different femoral neck fractures (FN) in synthetic bones subjected to vertical load. METHODS: Forty-two synthetic femurs were subjected to neck fractures and separated into 3 groups according to the Pauwels classification: Pauwels I had 6 units (PI); Pauwels II, 24 units, with and without comminution (PII); and Pauwels III, 12 units, with and without comminution (PIII). After, they were fixed with 2 different ways: three 7, 0 mm cannulated lag screws (CSs) versus three 6, 5 mm solid fully threaded screws (SSs). Screws positioning was oriented by the Pauwels classification: inverted triangle or crossed screws. All specimens were submitted to vertical loading until failure. RESULTS: The average force was 79.4 ± 22.6 Kgf. The greatest one was recorded in model 1 (135.6 Kgf), and the lowest in model 41 (39.6 Kgf). CSs and SSs had similar resistance until failure (p = 0.2). PI showed heightened resistance and PIII showed a worse response (p < 0,01). CSs had better performance in PIII (p = 0.048). Comminution and screws orientation caused no difference on peak force (p = 0.918 and p = 0.340, respectively). CONCLUSIONS: In synthetic bones, the resistance of a femoral neck fracture osteosynthesis using a 7, 0 mm cannulated lag screw or 6, 5 mm solid fully threaded screw are similar. There was no loss of efficiency with comminution in the femoral neck. Osteosynthesis resistance decreased with the verticalization of the fracture line and, in the more vertical ones, interfragmentary compression with CSs was more resistant than positional osteosynthesis with SSs.

5.
Traffic Inj Prev ; 25(4): 640-648, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38578292

RESUMO

OBJECTIVE: Occupant impact safety is critical for train development. This paper proposes a systematic procedure for developing validated numerical occupant crash scenarios for high-speed trains by integrating experimental, computational, and inverse methods. METHODS: As the train interior is the most potentially injury-causing factor, the material properties were acquired by mechanical tests, and constitutive models were calibrated using inverse methods. The validity of the seat material constitutive model was further verified via drop tower tests. Finite element (FE) and multibody (MB) models of train occupant-seat interactions in frontal impact were established in LS-DYNA and MADYMO software, respectively, using the experimentally acquired materials/mechanical characteristics. Three dummy sled crash tests with different folding table and backrest configurations were conducted to validate the numerical occupant-seat models and to further assess occupant injury in train collisions. The occupant impact responses between dummy tests and simulations were quantitatively compared using a correlation and analysis (CORA) objective rating method. RESULTS: Results indicated that the experimentally calibrated numerical seat-occupant models could effectively reproduce the occupant responses in bullet train collisions (CORA scores >80%). Compared with the train seat-occupant MB model, the FE model could simulate the head acceleration with slightly more acceptable fidelity, however, the FE model CORA scores were slightly less than for the MB models. The maximum head acceleration was 30 g but the maximum HIC score was 17.4. When opening the folding table, the occupant's chest injury was not obvious, but the neck-table contact and "chokehold" may potentially be severe and require further assessment. CONCLUSIONS: This study demonstrates the value of experimental data for occupant-seat model interactions in train collisions and provides practical help for train interior safety design and formulation of standards for rolling stock interior passive safety.


Assuntos
Acidentes de Trânsito , Traumatismos Torácicos , Humanos , Pescoço , Aceleração , Postura Sentada , Fenômenos Biomecânicos
6.
Molecules ; 29(6)2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38542842

RESUMO

This study concentrates on assessing the insecticidal attributes of the γ-Al2O3 nanoparticles derived from the remnants of Mentha pulegium, which include essential oil, ethanolic extract, and plant waste. The synthesis of the γ-Al2O3 nanoparticles was executed using a direct sol-gel procedure, affirming the crystal structure according to extensive physicochemical analyses such as UV-Vis, XRD, FTIR, and SEM. Evaluation of the insecticidal activity in vitro was conducted against Xylosandrus crassiusculus, a pest that infests carob wood, utilizing strains from diverse forests in the Khenifra region, situated in the Moroccan Middle Atlas. The lethal doses 50 ranged from 40 mg/g to 68 mg/g, indicating moderate effectiveness compared to the commercial insecticide Permethrin. Optimization of the conditions for the efficiency of the γ-Al2O3 nanoparticles was determined using experimental plans, revealing that time, humidity, and temperature were influential factors in the lethal dose 50 of these nanomaterials. Moreover, this study encompasses the establishment of correlations using Principal Component Analysis (PCA) and Ascending Hierarchical Classification (AHC) among various geographic, biological, and physical data, amalgamating geographic altitude and γ-Al2O3 nanoparticle insecticide parameters, as well as the attributes of the mechanical tests conducted on the carob wood affected by insects. The correlations highlight the close connections between the effectiveness of the insecticide, mountain altitude, and the mechanical parameters that were examined. Ultimately, these nanoparticles demonstrate promising potential as alternative insecticides, thus opening up encouraging prospects for safeguarding against carob wood pests.


Assuntos
Besouros , Galactanos , Inseticidas , Mananas , Mentha pulegium , Nanopartículas , Gomas Vegetais , Gorgulhos , Animais , Inseticidas/farmacologia , Inseticidas/química , Mentha pulegium/química
7.
Heliyon ; 10(5): e26796, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38444492

RESUMO

Regeneration of injured tendons and ligaments (T/L) is a worldwide need. In this study electrospun hierarchical scaffolds made of a poly-L (lactic) acid/collagen blend were developed reproducing all the multiscale levels of aggregation of these tissues. Scanning electron microscopy, microCT and tensile mechanical tests were carried out, including a multiscale digital volume correlation analysis to measure the full-field strain distribution of electrospun structures. The principal strains (εp1 and εp3) described the pattern of strains caused by the nanofibers rearrangement, while the deviatoric strains (εD) revealed the related internal sliding of nanofibers and bundles. The results of this study confirmed the biomimicry of such electrospun hierarchical scaffolds, paving the way to further tissue engineering and clinical applications.

8.
Data Brief ; 53: 110218, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38425877

RESUMO

Concrete is a prominent construction material globally, owing to its reputed attributes such as robustness, endurance, optimal functionality, and adaptability. Formulating concrete mixtures poses a formidable challenge, mainly when introducing novel materials and additives and evaluating diverse design resistances. Recent methodologies for projecting concrete performance in fundamental aspects, including compressive strength, flexural strength, tensile strength, and durability (encompassing homogeneity, porosity, and internal structure), exist. However, actual approaches need more diversity in the materials and properties considered in their analyses. This dataset outlines the outcomes of an extensive 10-year laboratory investigation into concrete materials involving mechanical tests and non-destructive assessments within a comprehensive dataset denoted as ConcreteXAI. This dataset encompasses evaluations of mechanical performances and non-destructive tests. ConcreteXAI integrates a spectrum of analyzed mixtures comprising twelve distinct concrete formulations incorporating diverse additives and aggregate types. The dataset encompasses 18,480 data points, establishing itself as a cutting-edge resource for concrete analysis. ConcreteXAI acknowledges the influence of artificial intelligence techniques in various science fields. Emphatically, deep learning emerges as a precise methodology for analyzing and constructing predictive models. ConcreteXAI is designed to seamlessly integrate with deep learning models, enabling direct application of these models to predict or estimate desired attributes. Consequently, this dataset offers a resourceful avenue for researchers to develop high-quality prediction models for both mechanical and non-destructive tests on concrete elements, employing advanced deep learning techniques.

9.
ACS Nano ; 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38334316

RESUMO

Erucamide is known to play a critical role in modifying polymer fiber surface chemistry and morphology. However, its effects on fiber crystallinity and mechanical properties remain to be understood. Here, synchrotron nanofocused X-ray Diffraction (nXRD) revealed a bimodal orientation of the constituent polymer chains aligned along the fiber axis and cross-section, respectively. Erucamide promoted crystallinity in the fiber, leading to larger and more numerous lamellae crystallites. The nXRD nanostructual characterization is complemented by single-fiber uniaxial tensile tests, which showed that erucamide significantly affected fiber mechanical properties, decreasing fiber tensile strength and stiffness but enhancing fiber toughness, fracture strain, and ductility. To correlate these single-fiber nXRD and mechanical test results, we propose that erucamide mediated slip at the interfaces between crystallites and amorphous domains during stress-induced single-fiber crystallization, also decreasing the stress arising from the shear displacement of microfibrils and deformation of the macromolecular network. Linking the single-fiber crystal structure with the single-fiber mechanical properties, these findings provide the direct evidence on a single-fiber level for the role of erucamide in enhancing fiber "softness".

10.
Int Endod J ; 57(5): 601-616, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38376108

RESUMO

AIM: To compare eight large- and low-tapered heat-treated reciprocating instruments regarding their design, metallurgy, mechanical properties, and irrigation flow through an in silico model. METHODOLOGY: A total of 472 new 25-mm E-Flex Rex (25/.04 and 25/.06), Excalibur (25/.05), Procodile (25/.06), Reciproc Blue R25 (25/.08v), WaveOne Gold Primary (25/.07v), and Univy Sense (25/.04 and 25/.06) instruments were evaluated regarding their design (stereomicroscopy, scanning electron microscopy, and 3D surface scanning), metallurgy (energy-dispersive X-ray spectroscopy and differential scanning calorimetry), and mechanical performance (cyclic fatigue, torsional resistance, cutting ability, bending and buckling resistance). Computational fluid dynamics assessment was also conducted to determine the irrigation flow pattern, apical pressure, and wall shear stress in simulated canal preparations. Kruskal-Wallis and one-way anova post hoc Tukey tests were used for statistical comparisons (α = 5%). RESULTS: Instruments presented variations in blade numbers, helical angles, and tip designs, with all featuring non-active tips, symmetrical blades, and equiatomic nickel-titanium ratios. Cross-sectional designs exhibited an S-shaped geometry, except for WaveOne Gold. Univy 25/.04 and Reciproc Blue displayed the smallest and largest core diameters at D3. Univy 25/.04 and E-Flex Rec 25/.04 demonstrated the longest time to fracture (p < .05). Reciproc Blue and Univy 25/.04 exhibited the highest and lowest torque to fracture, respectively (p < .05). Univy 25/.04 and Reciproc Blue had the highest rotation angles, whilst E-Flex Rec 25/.06 showed the lowest angle (p < .05). The better cutting ability was observed with E-Flex Rec 25/.06, Procodile, Excalibur, and Reciproc Blue (p > .05). Reciproc R25 and E-Flex Rec showed the highest buckling resistance values (p < .05), with WaveOne Gold being the least flexible instrument. The impact of instruments' size and taper on wall shear stress and apical pressure did not follow a distinct pattern, although Univy 25/.04 and E-Flex Rec 25/.06 yielded the highest and lowest values for both parameters, respectively. CONCLUSIONS: Low-tapered reciprocating instruments exhibit increased flexibility, higher time to fracture, and greater angles of rotation, coupled with reduced maximum bending loads and buckling strength compared to large-tapered instruments. Nevertheless, low-tapered systems also exhibit lower maximum torque to fracture and inferior cutting ability, contributing to a narrower apical canal enlargement that may compromise the penetration of irrigants in that region.


Assuntos
Instrumentos Odontológicos , Titânio , Estudos Transversais , Desenho de Equipamento , Teste de Materiais , Estresse Mecânico , Titânio/química , Preparo de Canal Radicular , Metalurgia
11.
Sensors (Basel) ; 24(2)2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38257632

RESUMO

Shore hardness (SH) is a cost-effective and easy-to-use method to assess soft tissue biomechanics. Its use for the plantar soft tissue could enhance the clinical management of conditions such as diabetic foot complications, but its validity and reliability remain unclear. Twenty healthy adults were recruited for this study. Validity and reliability were assessed across six different plantar sites. The validity was assessed against shear wave (SW) elastography (the gold standard). SH was measured by two examiners to assess inter-rater reliability. Testing was repeated following a test/retest study design to assess intra-rater reliability. SH was significantly correlated with SW speed measured in the skin or in the microchamber layer of the first metatarsal head (MetHead), third MetHead and rearfoot. Intraclass correlation coefficients and Bland-Altman plots of limits of agreement indicated satisfactory levels of reliability for these sites. No significant correlation between SH and SW elastography was found for the hallux, 5th MetHead or midfoot. Reliability for these sites was also compromised. SH is a valid and reliable measurement for plantar soft tissue biomechanics in the first MetHead, the third MetHead and the rearfoot. Our results do not support the use of SH for the hallux, 5th MetHead or midfoot.


Assuntos
Ossos do Metatarso , Adulto , Humanos , Fenômenos Biomecânicos , Dureza , Reprodutibilidade dos Testes , Pé/diagnóstico por imagem
13.
Biomedicines ; 11(12)2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-38137506

RESUMO

We evaluated and compared the biomechanical properties of Leukocyte-and Platelet Rich Fibrin L-PRF clots and membranes derived from smoker and nonsmoker donors. Twenty venous-blood donors (aged 18 to 50 years) were included after signing informed consent forms. L-PRF clots were analyzed and then compressed to obtain L-PRF membranes. L-PRF clot and membrane samples were tested in quasi-static uniaxial tension and the stress-stretch response was registered and characterized. Furthermore, scanning electron microscope representative images were taken to see the fibrin structure from both groups. The analysis of stress-stretch curves allowed us to evaluate the statistical significance in differences between smoker and nonsmoker groups. L-PRF membranes showed a stiffer response and higher tensile strength when compared to L-PRF clots. However, no statistically significant differences were found between samples from smokers and nonsmokers. With the limitations of our in vitro study, we can suggest that the tensile properties of L-PRF clots and membranes from the blood of smokers and nonsmokers are similar. More studies are necessary to fully characterize the effect of smoking on the biomechanical behavior of this platelet concentrate, to further encourage its use as an alternative to promote wound healing in smokers.

14.
J Mech Behav Biomed Mater ; 148: 106219, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37951146

RESUMO

In this study, a three-component biofilm for rapid wound dressing consisting of polyvinyl alcohol (PVA)/tannic acid (TA)/with CuO/SiO2 with different percentages (0, 5, 10, and 15 wt% NPs) is evaluated. In addition to controlling bleeding and absorption of blood and wound secretions, it protects the damaged tissue from the attack of microbes. It protects against viruses and thus reduces the treatment time. Analysis of biofilms morphology is performed by Field emission scanning electron microscopy (FE-SEM), phases in biofilms were analyzed by X-ray diffraction (XRD) analysis, chemical bonds, and functional groups are analyzed by Fourier transform infrared (FTIR) spectroscopy, and mechanical tests are performed to evaluate the strength of the samples. The thermogravimetric analysis (TGA) is applied to estimate the thermal stability of the biopolymer films with various percentages of CuO/SiO2 nanoparticles. Also, antibacterial test, bioactivity of the biofilms, the percentage of swelling ratio, and porosity of the samples were examined by immersing the samples in simulated body fluid (SBF) and Phosphate-buffered saline (PBS) for 14 days in vitro. The composite makeup of the TA/PVA sample, comprising 15 wt % CuO/SiO2 and containing 15 wt% of nanoparticles, exhibited superior heat resistance compared to other samples by an increase of 50 °C. This improvement can be attributed to the nanoparticles reaching their saturation point. The swelling ratio was assessed in both SBF and PBS, and in both instances, the sample increased by up to 10 wt% before decreasing, indicating the saturation of the nanoparticles.


Assuntos
Materiais Biocompatíveis , Álcool de Polivinil , Materiais Biocompatíveis/farmacologia , Materiais Biocompatíveis/química , Álcool de Polivinil/farmacologia , Álcool de Polivinil/química , Dióxido de Silício/farmacologia , Polímeros , Antibacterianos/farmacologia , Antibacterianos/química , Espectroscopia de Infravermelho com Transformada de Fourier
15.
Heliyon ; 9(9): e20194, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37809432

RESUMO

The global production of polymer materials has exploded in the last few decades. Their mechanical properties, erosion and corrosion resistance, good performance as insulation materials, and their ease and flexibility of manufacturing have made polymers one of the most widely used materials in the industry and in daily life. Several institutions and governments are beginning to raise serious environmental and ecological concerns with international impact soon, due to the increasing level of polymer production, which does not seem to be slowing down. It is necessary for the scientific community to make efforts in the development and evaluation of new methodologies to enable the inclusion of these types of materials in the circular economy of various production sectors. This is important in order to reduce the ecological impact caused by the current global production level of polymers. One of the most used methods for the recovery of polymeric materials is energy valorization through thermochemical processes. An example of this is thermal gasification using fuels composed of biomass and a mixture of polymeric waste from electrical and electronic equipment (WEEE). Through this thermochemical process, high-energy value synthesis gas, with a high concentration of hydrogen, is obtained on one hand, while waste products in the form of chars, ashes and slag are generated on the other hand. This manuscript presents a detailed study methodology that begins with chemical analysis of the raw material and includes subsequent analysis of mechanical results for the revaluation of these residual inert by-products, using them as partial substitutes in cement clinker to produce building mortars. This described methodology influences directly in the LCC (Life Cycle Costing) of final designed products in plastic and extend material life cycle Plastic materials are here to stay, so the study and optimization of polymer waste recovery processes are vital in achieving the Sustainable Development Goals (SDGs) set by the European Union in terms of efficiency and sustainability. It is also the only possible way to create an environmentally sustainable future world for future generations. After applying the described methodology, the mechanical test results show that the modified mortars exhibit established behaviour during the hardening time and similar strength growth compared to commercial mortars. The maximum mechanical strengths achieved, including compressive and flexural strength, make modified mortars a viable choice for several applications in the civil engineering sector.

16.
Dent Mater ; 39(9): 790-799, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37455205

RESUMO

OBJECTIVES: This study aimed to modify an experimental dental composite using a synthesized nano-structured methacrylated zirconium-based MOF to enhance physical/mechanical properties. METHODS: The previously known Uio-66-NH2 MOF was first synthesized and post-modified with Glycidyl Methacrylate (GMA). Fourier Transform Infrared (FTIR) Spectroscopy and CHNS analysis confirmed the post-modification reaction. The prepared filler was investigated by XRD, BET, SEM-EDS, and TEM. The experimental composite was prepared by mixing 60% wt. of resin matrix with 40% wt. of fillers, including silanized silica (SS) or Uio-66-NH-Me (UM). The experimental composites' depth of cure (DPC) was investigated in five groups (G1 =40% SS, G2 =30%SS+10%UM, G3 =20%SS+20%UM, G4 =10%SS+30%UM, G5 =40%UM). Then flexural strength(FS), Elastic Modulus(EM), solubility(S), water sorption(WS), degree of conversion(DC), polymerization shrinkage(PS), and polymerization stress(PSR) of the groups with DPC of more than 1 mm were investigated. Finally, the cytotoxicity of composites was studied. RESULTS: The groups with more than 20% wt. UM, filler (G4, G5) had lesser than 1 mm DPC. Therefore, we investigated three groups' physical and mechanical properties with lower than 20% UM filler (G1-G3). Within these groups, G3 has a higher FS, EM (P < 0.05), and lower WS and S (P < 0.05). DC dropped in G2 and G3 compared to G1 (p < 0.05), but there was no significant difference between G2 and G3 (P = 0.594). SIGNIFICANCE: This new filler is an innovative coupling-agent free filler and can be part of dental filler technology itself. It can also introduce a new group of dental fillers based on MOFs, but it still needs a complete investigation to be widely used.


Assuntos
Resinas Compostas , Estruturas Metalorgânicas , Resinas Compostas/química , Bis-Fenol A-Glicidil Metacrilato/química , Zircônio , Ácidos Polimetacrílicos/química , Propriedades de Superfície , Polietilenoglicóis/química , Metacrilatos/química , Dióxido de Silício/química , Teste de Materiais
17.
J Dent Res ; 102(10): 1106-1113, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37448337

RESUMO

Chemical and mechanical fatigue degradation in ceramic materials is generally inconspicuous yet ubiquitous, to the effect that clinical fractures still consist of the main cause of failure in all-ceramic restorations. Implications of this span wide, from a reduced survival prognosis for the affected teeth, including more frequent and increasingly invasive procedural interventions, to the financial burden borne by individuals and health care systems. To suffice as an effective corrective, restoration lifetimes need only to be extended so to outlive the patient. That opens a box of problems from a materials science standpoint, entailing inherent deficiencies of brittle materials to resist mechanical and environmental challenges. Efforts in developing more damage-tolerant and fatigue-resistant restoratives go thus hand in hand with understanding intrinsic mechanisms of crack growth behavior under conditions that simulate the oral environment. Here we developed experiments using size-relevant sharp precracked specimens with controlled size and geometry (truncated semielliptical crack in the surface-crack-in-biaxial-flexure method) to establish a relationship between crack size and strength. The tangent method was used to construct envelopes for the quasi-static resistance curves (R-curves), which served as template for deriving residual cyclic R-curve analogs. By means of experimentally obtained stress-cycle curves, lifetime and fatigue parameters were employed within a mechanistic framework to reveal constitutive toughening mechanisms during subcritical growth under cyclic loading in a wet environment. Using 3 modern dental lithium disilicate glass-ceramics, we demonstrate the extent of R-curve degradation up to a threshold of 10 million cycles (~30 y in service) and draw parallels between the scope of fatigue degradation and the size of the microstructural units responsible for toughening mechanisms in glass-ceramic materials. Our results indicate that larger microstructural elements endow glass-ceramics with a higher reaching quasi-static R-curve at the onset but degrading more rapidly to comparable levels of lithium disilicates having submicrometric and nanometric crystal phases.


Assuntos
Desenho Assistido por Computador , Porcelana Dentária , Humanos , Teste de Materiais , Análise do Estresse Dentário , Porcelana Dentária/química , Cerâmica/química , Propriedades de Superfície , Falha de Restauração Dentária
18.
Biomimetics (Basel) ; 8(2)2023 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-37366827

RESUMO

Fish skin is a biological material with high flexibility and compliance and can provide good mechanical protection against sharp punctures. This unusual structural function makes fish skin a potential biomimetic design model for flexible, protective, and locomotory systems. In this work, tensile fracture tests, bending tests, and calculation analyses were conducted to study the toughening mechanism of sturgeon fish skin, the bending response of the whole Chinese sturgeon, and the effect of bony plates on the flexural stiffness of the fish body. Morphological observations showed some placoid scales with drag-reduction functions on the skin surface of the Chinese sturgeon. The mechanical tests revealed that the sturgeon fish skin displayed good fracture toughness. Moreover, flexural stiffness decreased gradually from the anterior region to the posterior region of the fish body, which means that the posterior region (near the tail) had higher flexibility. Under large bending deformation, the bony plates had a specific inhibition effect on the bending deformation of the fish body, especially in the posterior region of the fish body. Furthermore, the test results of the dermis-cut samples showed that the sturgeon fish skin had a significant impact on flexural stiffness, and the fish skin could act as an external tendon to promote effective swimming motion.

19.
Gen Dent ; 71(4): 58-62, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37358585

RESUMO

Polyetheretherketone (PEEK) resin is a high-performance thermoplastic polymer that has been introduced as a possible candidate to replace metallic components in dental prostheses. The objective of this integrative review was to compare, through analysis of studies in the literature, the mechanical performance of removable partial denture frameworks and clasps manufactured with PEEK with the performance of cobalt-chromium (Co-Cr) frameworks and clasps. The guiding question was, "Does the use of PEEK as a substitute for Co-Cr alloys for the construction of removable partial denture frameworks result in better mechanical properties?" The PubMed/ MEDLINE, Embase, Web of Science, Scopus, and SciELO databases were searched for articles published through October 2021. The JBI Critical Appraisal Checklist for Quasi-Experimental Studies was used to assess the methodologic quality of the selected in vitro studies. A total of 208 articles were identified. After the exclusion of duplicates and articles that did not meet the inclusion criteria, 7 studies- -4 in vitro and 3 three-dimensional finite element analyses- -published between 2012 and 2021 were included in the integrative review. The appraisal checklist revealed that the reviewed studies had a low risk of bias and high methodologic quality. The results of the review showed that PEEK alloys have adequate mechanical properties for use in clasps and removable partial denture frameworks, but Co-Cr alloys exhibit better mechanical properties and are more suitable in most circumstances.


Assuntos
Prótese Parcial Removível , Humanos , Grampos Dentários , Ligas de Cromo , Polímeros , Polietilenoglicóis/uso terapêutico , Cetonas
20.
Dent Res J (Isfahan) ; 20: 37, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37180695

RESUMO

Background: Polymethyl methacrylate resin is widely used in orthodontic treatments. Graphene oxide (GO) has reactive functional groups on its surface that facilitate binding to various materials such as polymers, biomolecules, DNA, and proteins. This study aimed to investigate the impact of adding functionalized GO nanosheets on the physical, mechanical, cytotoxicity, and anti-biofilm properties of acrylic resin. Materials and Methods: In this experimental study, fifty samples (for each test) were divided into groups of 10, in the form of acrylic resin discs with concentrations of 0, 0.25, 0.5, 1, and 2 weight percentage (wt%) of functionalized GO nanosheets and also the control group. Samples were evaluated in terms of physical properties (surface hardness, surface roughness, compressive strength, fracture toughness, and flexural strength), anti-biofilm properties (On four groups of micro-organisms, including Streptococcus mutans, Streptococcus sanguis, Staphylococcus aureus, and Candida albicans), and cytotoxicity. Data were analyzed using SPSS software version 22, descriptive statistics, one-way analysis of variance test, and Tukey post hoc test. The significance level was considered P < 0.05. Results: No significant difference was observed between the different groups with weight percentages of 0.25, 0.5, 1, and 2% nano GO (nGO) and the control group (without nGO) in terms of surface roughness and toughness. However, compressive strength, three-point flexural strength, and surface hardness showed significant differences between the groups. Furthermore, the degree of cytotoxicity increased by increasing the weight percentage of nano-GO. Conclusion: The addition of functionalized nGO in appropriate concentrations to polymethyl methacrylate can improve the anti-bacterial and anti-fungal biofilm properties without changing or increasing their physical and mechanical properties.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...