Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Radiat Oncol J ; 36(3): 235-240, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30309215

RESUMO

PURPOSE: We describe the daily bladder volume change observed by mega-voltage computed tomography (MVCT) during pelvic radiotherapy with potential predictors of increased bladder volume variations. MATERIALS AND METHODS: For 41 patients who received pelvic area irradiation, the volumes of bladder and pelvic body contour were measured twice a day with pre- and post-irradiation MVCT from the 1st to the 10th fraction. The median prescription dose was 20 Gy (range, 18 to 30 Gy) up to a 10th fraction. The upper and lower margin of MVCT scanning was consistent during the daily treatments. The median age was 69 years (range, 33 to 86 years) and 10 patients (24.4%) were treated postoperatively. RESULTS: Overall bladder volume on planning computed tomography was 139.7 ± 92.8 mL. Generally, post-irradiation bladder volume (POSTBV) was larger than pre-irradiation bladder volume (PREBV) (p < 0.001). The mean PREBV and POSTBV was reduced after 10 fraction treatments by 21.3% (p = 0.028) and 25.4% (p = 0.007), respectively. The MVCT-scanned body contour volumes had a tendency to decrease as the treatment sessions progressed (p = 0.043 at the 8th fraction and p = 0.044 at the 10th fraction). There was a statistically significant correlation between bladder filling time and PREBV (p = 0.001). CONCLUSION: Daily MVCT-based bladder volume assessment was feasible both intra- and inter-fractionally.

2.
Radiation Oncology Journal ; : 235-240, 2018.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-741948

RESUMO

PURPOSE: We describe the daily bladder volume change observed by mega-voltage computed tomography (MVCT) during pelvic radiotherapy with potential predictors of increased bladder volume variations. MATERIALS AND METHODS: For 41 patients who received pelvic area irradiation, the volumes of bladder and pelvic body contour were measured twice a day with pre- and post-irradiation MVCT from the 1st to the 10th fraction. The median prescription dose was 20 Gy (range, 18 to 30 Gy) up to a 10th fraction. The upper and lower margin of MVCT scanning was consistent during the daily treatments. The median age was 69 years (range, 33 to 86 years) and 10 patients (24.4%) were treated postoperatively. RESULTS: Overall bladder volume on planning computed tomography was 139.7 ± 92.8 mL. Generally, post-irradiation bladder volume (POSTBV) was larger than pre-irradiation bladder volume (PREBV) (p < 0.001). The mean PREBV and POSTBV was reduced after 10 fraction treatments by 21.3% (p = 0.028) and 25.4% (p = 0.007), respectively. The MVCT-scanned body contour volumes had a tendency to decrease as the treatment sessions progressed (p = 0.043 at the 8th fraction and p = 0.044 at the 10th fraction). There was a statistically significant correlation between bladder filling time and PREBV (p = 0.001). CONCLUSION: Daily MVCT-based bladder volume assessment was feasible both intra- and inter-fractionally.


Assuntos
Humanos , Neoplasias Pélvicas , Prescrições , Radioterapia , Radioterapia de Intensidade Modulada , Bexiga Urinária
3.
Technol Cancer Res Treat ; 14(4): 467-74, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26269608

RESUMO

The intra- and inter-observer variability in delineation of the parotids on the kilo-voltage computed tomography (kVCT) and mega-voltage computed tomography (MVCT) were examined to establish their impact on the dose calculation during adaptive head and neck helical tomotherapy (HT). Three observers delineated left and right parotids for ten randomly selected patients with oropharynx cancer treated on HT. The pre-treatment kVCT and the MVCT from the first fraction of irradiation were selected to delineation. The delineation procedure was repeated three times by each observer. The parotids were delineated according to the institutional protocol. The analyses included intra-observer reproducibility and inter-structure, -observer and -modality variability of the volume and dose. The differences between the left and right parotid outlines were not statistically significant (p > 0.3). The reproducibility of the delineation was confirmed for each observer on the kVCT (p > 0.2) and on the MVCT (p > 0.1). The inter-observer variability of the outlines was significant (p < 0.001) as well as the inter-modality variability (p < 0.006). The parotids delineated on the MVCT were 10% smaller than on the kVCT. The inter-observer variability of the parotids delineation did not affect the average dose (p = 0.096 on the kVCT and p = 0.176 on the MVCT). The dose calculated on the MVCT was higher by 3.3% than dose from the kVCT (p = 0.009). Usage of the institutional protocols for the parotids delineation reduces intra-observer variability and increases reproducibility of the outlines. These protocols do not eliminate delineation differences between the observers, but these differences are not clinically significant and do not affect average doses in the parotids. The volumes of the parotids delineated on the MVCT are smaller than on the kVCT, which affects the differences in the calculated doses.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Glândula Parótida/efeitos da radiação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Variações Dependentes do Observador , Radioterapia de Intensidade Modulada/métodos
4.
J Med Phys ; 34(2): 73-9, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20098540

RESUMO

A Helical Tomotherapy (HT) Hi-Art II (TomoTherapy, Inc., Madison, WI, USA) has been one of the important innovations to help deliver IMRT with image guidance. On-board, mega voltage computed tomography (MVCT) detectors are used for imaging and dosimetric purpose. The two objectives of this study are: (i) To estimate the dosimetric and general capability (TomoImage registration, reconstruction, contrast and spatial resolution, artifacts-free image and dose in TomoImage) of on-board MVCT detectors. (ii) To measure the dosimetric parameters (output and energy) following major repair. The MVCT detectors also estimated the rotational output constancy well. During this study, dosimetric tests were repeated after replacing MVCT detectors and the target. fixed-gantry/fixed-couch measurements were measured daily to investigate; the system stability. Thermoluminescense dosimeter (TLD) was used during both the measurements subsequently. The MVCT image quality with old and new detectors was comparable and hence acceptable clinically. The spatial resolution was optimal and the dose during TomoImage was 2 cGy (well within the manufacturer tolerance of 4 cGy). The results of lateral beam profiles showed an excellent agreement between the two normalized plots. The output from the rotational procedure revealed 99.7% while the energy was consistent over a period of twelve months. The Hi-Art II system has maintained its calibration to within +/- 2% and energy to within +/- 1.5% over the initial twelve-month period. Based on the periodic measurements for rotational output and consistency in the lateral beam profile shape, the on-board detector proved to be a viable dosimetric quality assurance tool for IMRT with Tomotherapy. Tomotherapy was stable from the dosimetric point of view during the twelve-month period.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...