Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Spec Care Dentist ; 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38375899

RESUMO

BACKGROUND: Woolly Hair Syndrome (WHS) is a rare birth condition that affects the structure of hair in non-black people. The pathogenesis is not yet defined. It is postulated that the hair follicle's desmosomes (specifically desmoplaquine, placoglobin and placofilin-1, which are cell structural proteins that keep the adhesion among close cells) would be altered in this pathology, leading to fragility in the cellular union. It is subdivided into two large groups: the localized or circumscribed variant and the generalized variant. From birth or first months of life, patients with WHS are clinically characterized by the presence of a portion or entire scalp area of very short frizzy hair, usually of a smaller diameter, brittle and lighter color. The most frequent skin manifestations are pilar keratosis and palmo-plantar keratodermia. The diagnosis is based on the clinical findings, and it is facilitated by trichotoscopic examination. However, a definitive diagnosis of WHS requires genetic testing. Oral agenesis, enamel defects (such as hypomineralization), atypical caries, dental inclusion, and malformed pin-shaped teeth may occur. OBJECTIVE: To describe an aesthetic alternative of oral rehabilitation using the mock-up technique in a patient with WHS. CLINICAL CASE: A 5-year-old female patient diagnosed with WHS from the National Institute of Child Health NIHCH: Breña, Lima, who was referred from the Genetic service to the Pediatric Dentistry service in order to screen outbreaks of infection associated with odontogenic origin and dental anomalies. At the ectoscopy, a patient with short capillary length, brittle and curly hair, dry skin, and nail dystrophy was observed. At the intraoral clinical examination, anterior pieces of 52, 51, 61, 62, and enamel hypomineralization were observed in all teeth. The radiographic examination showed agenesis of parts 41, 34, and 45. Integral dental treatment was performed in the operating room under general anesthesia due to the complexity of the case. Pulpectomy in pieces 52, 51, 61, 62, post of composite resin, and rehabilitation with supra-nanow filling resin using the mock-up technique were proposed as alternative treatments. CONCLUSION: The making of supra-nano filling resin-based crowns using the mock-up technique is an alternative treatment for aesthetic oral rehabilitation in deciduous dentition of patients with WHS. The aesthetic treatment was achieved using supra nano-filling resins. After 12 months of dental treatment, a favorable response was observed, improving the chewing, phonation and aesthetics of the patient.

2.
Appl Radiat Isot ; 201: 111023, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37690167

RESUMO

During the physical start-up of the IVG.1M research reactor, which involved the conversion to low-enriched uranium fuel, various studies were conducted using physical mock-ups of the fuel assemblies. The mock-up consisted of 468 model low-enriched uranium fuel elements that were cut into three sections without end coatings at the cut locations. This configuration allowed for the simulation of fuel element decompression and the experimental determination of fission product release into the coolant. The coolant samples obtained from the mock-up were analyzed using a gamma-spectrometer equipped with a high-purity germanium detector. As a result of the studies, the activities of fission products in the coolant and the averaged relative fission product release were determined. The relative release is defined as the ratio of the release rate of reference fission products to its birth rate. For the first time, fission product release was experimentally obtained in a situation simulating the decompression of IVG.1M fuel cladding.

3.
Ann Biomed Eng ; 51(12): 2853-2872, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37635154

RESUMO

End-stage Fontan patients with single-ventricle (SV) circulation are often bridged-to-heart transplantation via mechanical circulatory support (MCS). Donor shortage and complexity of the SV physiology demand innovative MCS. In this paper, an out-of-the-box circulation concept, in which the left and right ventricles are switched with each other is introduced as a novel bi-ventricle MCS configuration for the "failing" Fontan patients. In the proposed configuration, the systemic circulation is maintained through a conventional mechanical ventricle assist device (VAD) while the venous circulation is delegated to the native SV. This approach spares the SV and puts it to a new use at the right-side providing the most-needed venous flow pulsatility to the failed Fontan circulation. To analyze its feasibility and performance, eight SV failure modes have been studied via an established multi-compartmental lumped parameter cardiovascular model (LPM). Here the LPM model is experimentally validated against the corresponding pulsatile mock-up flow loop measurements of a representative 15-year-old Fontan patient employing a clinically-approved VAD (Medtronic-HeartWare). The proposed surgical configuration maintained the healthy cardiac index (3-3.5 l/min/m2) and the normal mean systemic arterial pressure levels. For a failed SV with low ejection fraction (EF = 26%), representing a typical systemic Fontan failure, the proposed configuration enabled a ~ 28 mmHg amplitude in the venous/pulmonary waveforms and a 2 mmHg decrease in the central venous pressure (CVP) together with acceptable mean pulmonary artery pressures (17.5 mmHg). The pulmonary vascular resistance (PVR)-SV failure case provided a ~ 5 mmHg drop in the CVP, with venous/pulmonary pulsatility reaching to ~ 22 mmHg. For the high PVR failure case with a healthy SV (EF = 44%) pulmonary hypertension is likely to occur as expected. While this condition is routinely encountered during the heart transplantation and managed through pulmonary vasodilators a need for precise functional assessment of the spared failed-ventricle is recommended if utilized in the PVR failure mode. Comprehensive in vitro and in silico results encourage this novel concept as a low-cost, more physiological alternative to the conventional bi-ventricle MCS pending animal experiments.


Assuntos
Técnica de Fontan , Coração Auxiliar , Animais , Humanos , Adolescente , Ventrículos do Coração , Hemodinâmica/fisiologia , Coração , Resistência Vascular , Modelos Cardiovasculares
4.
Sensors (Basel) ; 23(15)2023 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-37571674

RESUMO

In this work, we introduce a novel approach to model the rain and fog effect on the light detection and ranging (LiDAR) sensor performance for the simulation-based testing of LiDAR systems. The proposed methodology allows for the simulation of the rain and fog effect using the rigorous applications of the Mie scattering theory on the time domain for transient and point cloud levels for spatial analyses. The time domain analysis permits us to benchmark the virtual LiDAR signal attenuation and signal-to-noise ratio (SNR) caused by rain and fog droplets. In addition, the detection rate (DR), false detection rate (FDR), and distance error derror of the virtual LiDAR sensor due to rain and fog droplets are evaluated on the point cloud level. The mean absolute percentage error (MAPE) is used to quantify the simulation and real measurement results on the time domain and point cloud levels for the rain and fog droplets. The results of the simulation and real measurements match well on the time domain and point cloud levels if the simulated and real rain distributions are the same. The real and virtual LiDAR sensor performance degrades more under the influence of fog droplets than in rain.

5.
J Pers Med ; 13(7)2023 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-37511641

RESUMO

INTRODUCTION: Several methods are currently available for providing a preview of the prosthodontic treatment, including computer simulations, 3D models, wax-ups, and mock-ups. The aim of this study is to compare the aesthetic aspects and assessment of conventional versus digital prefigurative methods. METHODS: The study included 5 patients and 3 observers, for each of whom a wax-up was made in both the conventional and digital techniques. The analog method, which implied a mock-up molding with a silicone matrix of the wax-up, was compared to a digital workflow, which consisted of a mock-up milling from a digital design. The patient's clinical mock-ups were recorded with digital photographs and assessed for nine different criteria by three observers. RESULTS: The analysis has shown a balanced assessment of the aesthetic criteria without any significant difference between the analog and digital prefigurative methods. CONCLUSIONS: Between the two wax-ups (conventional and digital), there were some variations in smile and dental criteria; however, the obtained data were very similar. When it comes to the smile criteria, the general average grades of the mock-ups conducted using the conventional method are slightly higher than the ones using the digital technique.

6.
Prim Dent J ; 12(2): 46-56, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37313879

RESUMO

The burgeoning public interest in techniques to enhance a smile has led to demand on clinicians that require important steps in the pre-treatment approval process. Digital dentistry provides a new level of planning and visualisation, improving clinical risk assessment and patient engagement. Dentists must acquire a sound understanding of aesthetic design parameters, including physiologic limitations, and must match patient expectations with clinical reality. Digital design offers flexibility not obtainable with the conventional analogue wax up. Multiple versions of a design can be viewed in a 2D or 3D simulation and accommodated efficiently in CAD software, with 3D printed models generated from each design. The ability to use a test drive or mock-up based on a 3D digital analysis and design, has created a new standard of care for treatment planning, providing an accurate and reversible preview before any definitive dentistry is done. It also places the responsibility for understanding biologic limitations of care on the general dentist, with the risk that digital planning may over-promise if not matched with underlying hard and soft tissue conditions. It improves interdisciplinary and laboratory communication and increases the predictability of the proposed treatment. The result is greater patient satisfaction and an improved informed consent process.


Assuntos
Comunicação , Estética Dentária , Humanos , Satisfação do Paciente , Medição de Risco
7.
Sensors (Basel) ; 23(6)2023 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-36991824

RESUMO

Measurement performance evaluation of real and virtual automotive light detection and ranging (LiDAR) sensors is an active area of research. However, no commonly accepted automotive standards, metrics, or criteria exist to evaluate their measurement performance. ASTM International released the ASTM E3125-17 standard for the operational performance evaluation of 3D imaging systems commonly referred to as terrestrial laser scanners (TLS). This standard defines the specifications and static test procedures to evaluate the 3D imaging and point-to-point distance measurement performance of TLS. In this work, we have assessed the 3D imaging and point-to-point distance estimation performance of a commercial micro-electro-mechanical system (MEMS)-based automotive LiDAR sensor and its simulation model according to the test procedures defined in this standard. The static tests were performed in a laboratory environment. In addition, a subset of static tests was also performed at the proving ground in natural environmental conditions to determine the 3D imaging and point-to-point distance measurement performance of the real LiDAR sensor. In addition, real scenarios and environmental conditions were replicated in the virtual environment of a commercial software to verify the LiDAR model's working performance. The evaluation results show that the LiDAR sensor and its simulation model under analysis pass all the tests specified in the ASTM E3125-17 standard. This standard helps to understand whether sensor measurement errors are due to internal or external influences. We have also shown that the 3D imaging and point-to-point distance estimation performance of LiDAR sensors significantly impacts the working performance of the object recognition algorithm. That is why this standard can be beneficial in validating automotive real and virtual LiDAR sensors, at least in the early stage of development. Furthermore, the simulation and real measurements show good agreement on the point cloud and object recognition levels.

8.
Sensors (Basel) ; 22(19)2022 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-36236655

RESUMO

This work introduces a process to develop a tool-independent, high-fidelity, ray tracing-based light detection and ranging (LiDAR) model. This virtual LiDAR sensor includes accurate modeling of the scan pattern and a complete signal processing toolchain of a LiDAR sensor. It is developed as a functional mock-up unit (FMU) by using the standardized open simulation interface (OSI) 3.0.2, and functional mock-up interface (FMI) 2.0. Subsequently, it was integrated into two commercial software virtual environment frameworks to demonstrate its exchangeability. Furthermore, the accuracy of the LiDAR sensor model is validated by comparing the simulation and real measurement data on the time domain and on the point cloud level. The validation results show that the mean absolute percentage error (MAPE) of simulated and measured time domain signal amplitude is 1.7%. In addition, the MAPE of the number of points Npoints and mean intensity Imean values received from the virtual and real targets are 8.5% and 9.3%, respectively. To the author's knowledge, these are the smallest errors reported for the number of received points Npoints and mean intensity Imean values up until now. Moreover, the distance error derror is below the range accuracy of the actual LiDAR sensor, which is 2 cm for this use case. In addition, the proving ground measurement results are compared with the state-of-the-art LiDAR model provided by commercial software and the proposed LiDAR model to measure the presented model fidelity. The results show that the complete signal processing steps and imperfections of real LiDAR sensors need to be considered in the virtual LiDAR to obtain simulation results close to the actual sensor. Such considerable imperfections are optical losses, inherent detector effects, effects generated by the electrical amplification, and noise produced by the sunlight.

9.
Medicina (Kaunas) ; 58(10)2022 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-36295521

RESUMO

Background and Objectives: The report describes a technique using a diagnostic mock-up as a crown-lengthening surgical guide to improve the gingival architecture. Materials and Methods: The patient's primary concern was improving her smile due to her "gummy smile" and short clinical crowns. After clinical evaluation, surgical crown lengthening accompanied by maxillary central full-coverage single-unit prostheses and lateral incisor veneers was recommended. The diagnostic mock-up was placed in the patient's maxillary anterior region and used as a soft tissue reduction guide for the gingivectomy. Once the planned gingival architecture was achieved, a flap was reflected to proceed with ostectomy in order to obtain an appropriate alveolar bone crest level using the overlay. After six months, all-ceramic crowns and porcelain veneers were provided as permanent restorations. Results: A diagnostic mock-up fabricated with a putty guide directly from the diagnostic wax-up can be an adequate surgical guide for crown-lengthening procedures. The diagnostic wax-up was used to fabricate the diagnostic mock-up. These results suggested that it can be used as a crown-lengthening surgical guide to modify the gingival architecture. Several advantages of the overlay used in the aesthetic complex case include: (1) providing a preview of potential restorative outcomes, (2) allowing for the appropriate positioning of gingival margins and the desired alveolar bone crest level for the crown-lengthening procedure, and (3) serving as a provisional restoration after surgery. Conclusions: The use of a diagnostic mock-up, which was based on a diagnostic wax-up, as the surgical guide resulted in successful crown lengthening and provisional restorations. Thus, a diagnostic overlay can be a viable option as a surgical guide for crown lengthening.


Assuntos
Aumento da Coroa Clínica , Porcelana Dentária , Humanos , Feminino , Aumento da Coroa Clínica/métodos , Gengivectomia/métodos , Coroas , Incisivo
10.
Biomedicines ; 10(10)2022 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-36289798

RESUMO

The materials available today allow for extensive oral rehabilitations in a non-invasive way, and often an orthodontic preparation is useful and, thanks to the use of clear aligners, is predictable and comfortable. A preliminary study of the wax-up, mock-up, and set-up allow the clinician to plan every aspect of the treatment in detail. Furthermore, the procedure offers the patient an intuitive and understandable view of the expected final result. The new proposed method, called "speed up therapy", allows for the integration of the orthodontic set-up with the mock-up technique, simulating the occlusal and aesthetic components of the planned restoration, in all details. The clinical case presented, demonstrates step by step the predictability and clinical reliability of the proposed procedure. The final clinical result coincides exactly with the initial mock-up and demonstrates that the proposed method is predictable and reliable. The correct execution of the technique is rigorously customized, and its success is operator dependent, both for the clinical aspects and for the dental laboratory. Thus, the visualization of the objectives of the treatment constitutes a decisive support for the clinician and provides the patient with the possibility of benefiting from an immediate improvement by making it easier for them to accept a treatment plan. The visualization also includes an orthodontic phase that potentially lengthens the treatment but makes the realization more conservative and predictable.

11.
Cureus ; 14(7): e27402, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36046283

RESUMO

This report describes the importance of and outlines steps for additive wax-up and diagnostic mockup for anterior teeth as diagnostic and driving tools for non-prep and minimally invasive veneer preparations. A 35-year-old male presented to the clinic with the chief complaint of spaces between his front teeth. Diagnostic additive wax-up provided the possibility of offering minimally invasive preparations, and the use of a diagnostic intraoral mockup fulfilled the patient's esthetic demands for treatment approval. Veneer preparations over the diagnostic mockup were provided as they are minimally invasive. Ceramic veneers were hand-crafted following the previous diagnostic wax-up, and restorations were bonded under rubber dam isolation. Overall, additive wax-up provides information needed to know if minimally invasive veneer preparations are possible, and the diagnostic mockup displays a physical, tentative outcome for the patient's evaluation before irreversible tooth preparations. These simple, but effective, techniques can drive the diagnosis and prognosis of minimally invasive veneer restorations.

12.
J Prosthodont ; 31(6): 543-548, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35343618

RESUMO

Treatment planning for the transition of patients from terminal dentition to full-arch implant rehabilitation poses challenges. Such challenges pertain to achieving the new orientation of the occlusal and esthetic plane as well as the change of vertical dimension of occlusion (VDO), while the fixed provisionalization using a digital workflow still tends to be considered complex and hard to perform. This article illustrates step-by-step the utilization of a digital workflow protocol in the treatment planning for rehabilitation of terminal dentition patients, simplifying the smile design and ensuring that fixed provisionalization serves both functional and esthetic requirements. This protocol includes facially driven, three-dimensional (3D) digital smile design and chairside mock-up restoration workflows that enable prosthetically driven assessment prior to implant treatment planning and 3D printing of surgical templates and prefabricated interim prostheses, which can predictably reduce chairside time and adjustments at the surgical and fixed provisionalization appointment.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Desenho Assistido por Computador , Dentição , Estética Dentária , Humanos , Fluxo de Trabalho
13.
J Prosthodont Res ; 66(3): 445-451, 2022 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-34588399

RESUMO

PURPOSE: Although mock-ups have been widely used in dental esthetic rehabilitation, their accuracy has not been quantitatively evaluated, and the methods of fabricating mock-ups are various. This in vitro study investigated the thickness accuracy of mock-ups fabricated with different silicone matrices. METHODS: Mock-ups of maxillary anterior teeth were respectively fabricated by 72 silicone matrices that were equally divided into four groups (n=18 for each group) according to two variables of the silicone matrices: labial margin position (equigingival or cover labial gingiva for 1-2 mm) and palatal notches (with or without notches on the palatal side of silicone matrices). The thickness accuracy of the mock-ups was analyzed using 3D scanning and 3D deviation analysis techniques compared with diagnostic waxing. The thickness change ratios of the mock-ups were compared using a two-way analysis of variance (ANOVA). One-way ANOVA and Kruskal-Wallis tests were used to compare differences in thickness change ratios between different teeth in each group. RESULTS: The thickness accuracy of the mock-ups was significantly affected by the labial margin position and the palatal notches of the silicone matrices, respectively, in the labial area and the incisal area. The most accurate mock-ups were made using silicone matrices with equigingival labial margins and palatal notches. The thickness accuracy of the mock-ups was also inconsistent on different teeth. CONCLUSION: The mock-ups fabricated by silicone matrices were thicker than the diagnostic waxing. The application of silicone matrices to equigingival labial margins and palatal notches was beneficial to the thickness accuracy of mock-ups.


Assuntos
Palato , Silicones , Análise de Variância , Maxila
14.
Appl Ergon ; 98: 103603, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34638037

RESUMO

Auditory comfort evaluations are garnering increased attention in engineering and particularly in the context of air transportation. Being able to produce sound environments corresponding to various flight conditions in aircraft mock-ups would be a valuable tool to investigate acoustic comfort inside aircrafts in controlled environments. Before using such mock-ups, they must be developed and validated in physical and perceptual terms. This paper provides a perceptual validation of sound environment reproduction inside aircraft mock-up. To provide a faithfully reproduced sound environment, time, frequency and spatial characteristics should be preserved. Physical sound field reproduction approaches for spatial sound reproduction are required while properly preserving localization cues at the listener's ears to recreate a realistic and immersing sound environment. We report a perceptual validation of a sound field reproduction system developed in an aircraft mock-up based on multichannel least-square methods and equalization. Twenty participants evaluated reproduced sound environments relative to a reference sound environment in an aircraft cabin mock-up equipped with a 41-actuator multichannel sound reproduction system. Results indicate that the preferred reproduction corresponds to the best physical reconstruction of the sound environment.


Assuntos
Aeronaves , Som , Atenção , Sinais (Psicologia) , Humanos , Reprodução
15.
HERD ; 15(2): 116-133, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34510942

RESUMO

OBJECTIVE: The purpose of this study was to compare perceptions and behaviors of end users participating in simulations in a high-fidelity physical mock-up of an operating room (OR) prototype with the perceptions and behaviors of end users in the built out ORs postoccupancy. BACKGROUND: Simulation-based evaluations of high-fidelity physical mock-ups of proposed layouts are increasingly being conducted during the facility design process to understand impacts on workflow and potential adverse patient safety outcomes. Nevertheless, it is unclear to what extent user experiences in these simulated healthcare spaces are similar to those in built and occupied healthcare environments. METHODS: Using interviews, surveys, and observations, this study compared user evaluations in a high-fidelity physical mock-up of an OR with user evaluations of the built and occupied OR postoccupancy. Workflow disruptions were also analyzed using video recordings for a simulated pediatric surgery and five pediatric surgeries in the actual OR. RESULTS: This study found that user perceptions and behavior in the two types of environments were mostly similar with regard to perceived support for the location of surgeon workstation, perceived space and task performance, perceived access to storage locations, boom setup, and OR cleanability. Participant's ratings differed for supportiveness of the mobile Circulating Nurse (CN) workstation, maneuvering booms, and environmental disruptions. CONCLUSION: Simulation-based evaluations are extremely beneficial during the design process and can provide valuable input to design teams as well as clinical teams about workflow and safety issues that allow design issues to be addressed before construction.


Assuntos
Arquitetura de Instituições de Saúde , Salas Cirúrgicas , Criança , Simulação por Computador , Humanos , Análise e Desempenho de Tarefas , Fluxo de Trabalho
16.
Artigo em Inglês | MEDLINE | ID: mdl-34769768

RESUMO

(1) Background: There are many complexities and trade-offs that design teams consider when designing or renovating a built environment for healthcare. Virtual reality (VR) mock-ups can allow design teams to evaluate the planned design. This study aimed to examine the overall value of using VR mock-ups to conduct a simulation-based mock-up evaluation. (2) Methods: Data collected from scenario enactments within a VR mock-up was compared to data collected from an existing medication room with the same design to assess predictive validity. Outcomes regarding quality and patient safety were also examined as a result of design modifications to the VR mock-up which were identified through a post-occupancy evaluation (POE) of the existing medication room. Survey data from participants, hospital design stakeholders, and POE recommendation recipients captured perceptions regarding the evaluation process. Specifically, this included perceptions regarding mock-up and scenario realism as well as utility of the evaluation process. (3) Results: Evidence-based data collected using the VR mock-up accurately assessed workflow (link analysis), bumps, impediments, interruptions, and task completion times. Collecting data pertaining to selection errors and equipment placement were identified after procuring the VR software and therefore the accuracy of these measures was not assessed. Searching behaviours were not possible to capture using the VR software. A 506% return on investment was achieved through the VR mock-up evaluations. (4) Conclusion: Organizations should consider what evaluation objectives are planned and how they will be measured for a mock-up evaluation to determine if VR is appropriate.


Assuntos
Arquitetura Hospitalar , Realidade Virtual , Simulação por Computador , Prática Clínica Baseada em Evidências , Humanos , Inquéritos e Questionários
17.
J Clin Med ; 10(22)2021 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-34830619

RESUMO

ECMO is the most frequently used mechanical support for patients suffering from low cardiac output syndrome. Combining IABP with ECMO is believed to increase coronary artery blood flow, decrease high afterload, and restore systemic pulsatile flow conditions. This study evaluates that combined effect on coronary artery flow during various load conditions using an in vitro circuit. In doing so, different clinical scenarios were simulated, such as normal cardiac output and moderate-to-severe heart failure. In the heart failure scenarios, we used peripheral ECMO support to compensate for the lowered cardiac output value and reach a default normal value. The increase in coronary blood flow using the combined IABP-ECMO setup was more noticeable in low heart rate conditions. At baseline, intermediate and severe LV failure levels, adding IABP increased coronary mean flow by 16%, 7.5%, and 3.4% (HR 60 bpm) and by 6%, 4.5%, and 2.5% (HR 100 bpm) respectively. Based on our in vitro study results, combining ECMO and IABP in a heart failure setup further improves coronary blood flow. This effect was more pronounced at a lower heart rate and decreased with heart failure, which might positively impact recovery from cardiac failure.

18.
Front Med Technol ; 3: 702656, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35047942

RESUMO

This study aims at proposing and discussing useful indications to all those who need to validate a numerical model of coronary stent deployment. The proof of the reliability of a numerical model is becoming of paramount importance in the era of in silico trials. Recently, the ASME V&V Standard Committee for medical devices prepared the V&V 40 standard document that provides a framework that guides users in establishing and assessing the relevance and adequacy of verification and validation activities performed for proving the credibility of models. To the knowledge of the authors, only a few examples of the application of the V&V 40 framework to medical devices are available in the literature, but none about stents. Specifically, in this study, the authors wish to emphasize the choice of a relevant set of experimental activities to provide data for the validation of computational models aiming to predict coronary stent deployment. Attention is focused on the use of ad hoc 3D-printed mock vessels in the validation plan, which could allow evaluating aspects of clinical relevance in a representative but controlled environment.

19.
BMC Oral Health ; 20(1): 165, 2020 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-32503567

RESUMO

BACKGROUND: Mock-up based approach allows the preview of the aesthetic rehabilitation, however, it is crucial that the mock-up does not differ from the expected aesthetic outcomes. With CAD-CAM technologies, it is possible to directly create mock-ups from virtual planned smile project, with greater accuracy and efficiency compared to the conventional moulded mock-ups. In this study, we investigated the trueness of mock-ups obtained with milling and 3D printing technology and a full digital work-flow system. METHODS: Ten adults subjects were included and digital smile design/digital wax-up were performed to enhance the aesthetic of maxillary anterior region. Ten milled mock-ups and 10 prototyped mock-ups were obtained from the original .stl file and a digital analysis of trueness was carried out by superimposing the scanned-milled mock-ups and the scanned-prototyped mock-ups to the digital wax-up, according to the surface-to-surface matching technique. Specific linear measurements were performed to investigate and compare the dimensional characteristics of the physical manufactures, the 3D project and the scanned mock-ups. All data were statistically analyzed. A clinical test was also performed to assess the fitting of the final manufacture. RESULTS: The prototyped mock-ups showed a significant increment of the transversal measurements (p < 0.001) while the milled mock-ups showed a significant increment of all vertical and transversal measurements (p < 0.001). The prototyped mock-ups showed good fitting after clinical tests while none of the milled mock-ups showed good adaptation (no fitting or significant clinical compensation required). Deviation analysis from the original 3D project reported a greater matching percentage for the scanned-milled mock-ups (80,31% ± 2.50) compared to the scanned-prototyped mock-ups (69,17% ± 2.64) (p < 0.001). This was in contrast with the findings from linear measurements as well as from the clinical test and may have been affected by a reductive algorithmic computation after digitization of physical mock-ups. CONCLUSION: Both prototype and milled mock-ups showed a slight dimensional increment comparing to the original 3D project, with milled-mock-ups showing less fitting after clinical tests. Caution must be taken when assessing the trueness of scanned manufacture since an intrinsic error in the system can underestimate the dimensions of the real object.


Assuntos
Desenho Assistido por Computador , Estética Dentária , Adulto , Humanos , Impressão Tridimensional , Sorriso
20.
J Med Life ; 13(1): 82-86, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32341706

RESUMO

The demographic statistics indicate that, with the industrial development and the advances in the medical field, the average life of the population has started to increase significantly; consequently, the needs of treatments in geriatric dentistry are becoming more and more significant. The purpose of this study was to evaluate patients' perception of diverse techniques used to obtain previews for final fixed prosthetic restorations: digital smile design (DSD), wax-up, indirect mock-up, temporary restorations, Computer-Aided Design (CAD). A focus group that included 11 participants, all of them geriatric patients, was formed; patients were invited to respond to a set of seven questions before and after various previsualization methods were applied. The focus-group report indicated that the indirect mock-up and the temporary restorations were considered by the geriatric patients as the best methods for obtaining good prosthetic previews. Comparing to the other tested methods, the use of indirect mock-up increased the acceptance of the prosthetic treatment plan and offered the most influential visual impact for 72.7% of participants. In addition, all tested previews allowed excellent communication with patients, the best results being obtained with the temporary prosthetic restorations (for 54.5% of participants). This approach represented a tool for better decisions regarding final dental restoration and has had a positive influence on patients' acceptance of the treatment plan as well, making the final restoration more predictable.


Assuntos
Conhecimentos, Atitudes e Prática em Saúde , Próteses e Implantes , Idoso , Desenho Assistido por Computador , Feminino , Grupos Focais , Humanos , Masculino , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...