Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Materials (Basel) ; 17(2)2024 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-38255459

RESUMO

When describing the tribological behaviour of technical surfaces, the need for full-length scale microtopographic characterization often arises. The self-affine of surfaces and the characterisation of self-affine using a fractal dimension and its implantation into tribological models are commonly used. The goal of our present work was to determine the frequency range of fractal behaviour of surfaces by analysing the microtopographic measurements of an anodised aluminium brake plunger. We also wanted to know if bifractal and multifractal behaviour can be detected in real machine parts. As a result, we developed a new methodology for determining the fractal range boundaries to separate the nano- and micro-roughness. To reach our goals, we used an atomic force microscope (AFM) and a stylus instrument to obtain measurements in a wide frequency range (19 nm-3 mm). Power spectral density (PSD)-based fractal evaluation found that the examined surface could not be characterised by a single fractal dimension. A new method capable of separating nano- and micro-roughness has been developed for investigating multifractal behaviour. The presented procedure separates nano- and micro-roughness based on the geometric characteristics of surfaces. In this way, it becomes possible to specifically examine the relationship between the micro-geometry that can be measured in each wavelength range and the effects of cutting technology and the material structure that creates them.

2.
Materials (Basel) ; 16(18)2023 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-37763418

RESUMO

Due to the expansion of the use of powder bed fusion metal additive technologies in the medical field, especially for the realization of dental prostheses, in this paper, the authors propose a comparative experimental study of the mechanical characteristics and the state of their microscale surfaces. The comparison was made from material considerations starting from two dental alloys commonly used to realize dental prostheses: Ni-Cr and Co-Cr, but also technologies for obtaining selective laser melting (SLM) and conventional casting. In addition, to compare the performances with the classical casting technology, for the dental prostheses obtained through SLM, the post-processing stage in which they are in a preliminary finishing and polished state was considered. Therefore, for the determination of important mechanical characteristics and the comparative study of dental prostheses, the indentation test was used, after which the hardness, penetration depths (maximum, permanent, and contact depth), contact stiffness, and contact surface were established, and for the determination of the microtopography of the surfaces, atomic force microscopy (AFM) was used, obtaining the local areal roughness parameters at the miniaturized scale-surface average roughness, root-mean-square roughness (RMS), and peak-to-peak values. Following the research carried out, several interesting conclusions were drawn, and the superiority of the SLM technology over the classic casting method for the production of dental prostheses in terms of some mechanical properties was highlighted. At the same time, the degree of finishing of dental prostheses made by SLM has a significant impact on the mechanical characteristics and especially the local roughness parameters on a miniaturized scale, and if we consider the same degree of finishing, no major differences are observed in the roughness parameters of the surfaces of the prostheses produced by different technologies.

3.
Nanomaterials (Basel) ; 13(7)2023 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-37049240

RESUMO

Nanoscale surface roughness has conventionally been induced by using complicated approaches; however, the homogeneity of superhydrophobic surface and hazardous pollutants continue to have existing challenges that require a solution. As a prospective solution, a novel bubbled-structured silica nanoparticle (SiO2) decorated electrospun polyurethane (PU) nanofibrous membrane (SiO2@PU-NFs) was prepared through a synchronized electrospinning and electrospraying process. The SiO2@PU-NFs nanofibrous membrane exhibited a nanoscale hierarchical surface roughness, attributed to excellent superhydrophobicity. The SiO2@PU-NFs membrane had an optimized fiber diameter of 394 ± 105 nm and was fabricated with a 25 kV applied voltage, 18% PU concentration, 20 cm spinning distance, and 6% SiO2 nanoparticles. The resulting membrane exhibited a water contact angle of 155.23°. Moreover, the developed membrane attributed excellent mechanical properties (14.22 MPa tensile modulus, 134.5% elongation, and 57.12 kPa hydrostatic pressure). The composite nanofibrous membrane also offered good breathability characteristics (with an air permeability of 70.63 mm/s and a water vapor permeability of 4167 g/m2/day). In addition, the proposed composite nanofibrous membrane showed a significant water/oil separation efficiency of 99.98, 99.97, and 99.98% against the water/xylene, water/n-hexane, and water/toluene mixers. When exposed to severe mechanical stresses and chemicals, the composite nanofibrous membrane sustained its superhydrophobic quality (WCA greater than 155.23°) up to 50 abrasion, bending, and stretching cycles. Consequently, this composite structure could be a good alternative for various functional applications.

4.
Nanomaterials (Basel) ; 12(18)2022 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-36145044

RESUMO

The boiling crisis or critical heat flux (CHF) is a very critical constraint for any heat-flux-controlled boiling system. The existing methods (physical models and empirical correlations) offer a specific interpretation of the boiling phenomenon, as many of these correlations are considerably influenced by operational variables and surface morphologies. A generalized correlation is virtually unavailable. In this study, more physical mechanisms are incorporated to assess CHF of surfaces with micro- and nano-scale roughness subject to a wide range of operating conditions and working fluids. The CHF data is also correlated by using the Pearson, Kendal, and Spearman correlations to evaluate the association of various surface morphological features and thermophysical properties of the working fluid. Feature engineering is performed to better correlate the inputs with the desired output parameter. The random forest optimization (RF) is used to provide the optimal hyper-parameters to the proposed interpretable correlation and experimental data. Unlike the existing methods, the proposed method is able to incorporate more physical mechanisms and relevant parametric influences, thereby offering a more generalized and accurate prediction of CHF (R2 = 0.971, mean squared error = 0.0541, and mean absolute error = 0.185).

5.
Polymers (Basel) ; 13(22)2021 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-34833321

RESUMO

The surface functionalisation of high-density polyethylene (HDPE) and HDPE/alumina-toughened zirconia (ATZ) surfaces with chitosan via electron-beam (EB) irradiation technique was exploited for preparing materials suitable for biomedical purposes. ATR-FTIR analysis and wettability measurements were employed for monitoring the surface changes after both irradiation and chitosan grafting reaction. Interestingly, the presence of ATZ loadings beyond 2 wt% influenced both the EB irradiation process and the chitosan functionalisation reaction, decreasing the oxidation of the surface and the chitosan grafting. The EB irradiation induced an increase in Young's modulus and a decrease in the elongation at the break of all analysed systems, whereas the tensile strength was not affected in a relevant way. Biological assays indicated that electrostatic interactions between the negative charges of the surface of cell membranes and the -NH3+ sites on chitosan chains promoted cell adhesion, while some oxidised species produced during the irradiation process are thought to cause a detrimental effect on the cell viability.

6.
Carbohydr Polym ; 255: 117431, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33436230

RESUMO

It has been a consistent challenge to develop eco-friendly packaging in its entire life cycle with multiple barriers. Herein, a lignocellulose-derived strategy was developed for enhancing barrier properties of cellulose-based packaging. Porosity and hydrophilicity of paper packaging were remedied by the sequential deposition of oxalic acid modified microfibrillated cellulose (OMFC) and infiltration of nanosized alkaili lignin (NAL). OMFC deposition and NAL infiltration could fill the void among fibers and create hydrophobic micro/nano-roughness on paper surface, which showed synergetic effect on enhancing barrier and mechanical properties by self-bonding and crosslinking between cellulose and lignin. Water vapor transmission rate was reduced by 93 % with initial water contact angle at 113°. Besides, more than four-fold increase in tensile strength along with persisted water and grease resistance were achieved. The result suggests the barrier-enhanced packaging by multilayer surface construction has great potential in bio-based applications considering the biodegradability, biocompatibility, and recyclability.

7.
Int J Mol Sci ; 21(3)2020 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-31991761

RESUMO

Titanium implants are the standard therapeutic option when restoring missing teeth and reconstructing fractured and/or diseased bone. However, in the 30 years since the advent of micro-rough surfaces, titanium's ability to integrate with bone has not improved significantly. We developed a method to create a unique titanium surface with distinct roughness features at meso-, micro-, and nano-scales. We sought to determine the biological ability of the surface and optimize it for better osseointegration. Commercially pure titanium was acid-etched with sulfuric acid at different temperatures (120, 130, 140, and 150 °C). Although only the typical micro-scale compartmental structure was formed during acid-etching at 120 and 130 °C, meso-scale spikes (20-50 µm wide) and nano-scale polymorphic structures as well as micro-scale compartmental structures formed exclusively at 140 and 150 °C. The average surface roughness (Ra) of the three-scale rough surface was 6-12 times greater than that with micro-roughness only, and did not compromise the initial attachment and spreading of osteoblasts despite its considerably increased surface roughness. The new surface promoted osteoblast differentiation and in vivo osseointegration significantly; regression analysis between osteoconductivity and surface variables revealed these effects were highly correlated with the size and density of meso-scale spikes. The overall strength of osseointegration was the greatest when the acid-etching was performed at 140 °C. Thus, we demonstrated that our meso-, micro-, and nano-scale rough titanium surface generates substantially increased osteoconductive and osseointegrative ability over the well-established micro-rough titanium surface. This novel surface is expected to be utilized in dental and various types of orthopedic surgical implants, as well as titanium-based bone engineering scaffolds.


Assuntos
Regeneração Óssea , Nanoestruturas/química , Osseointegração , Titânio/química , Animais , Adesão Celular , Diferenciação Celular , Células Cultivadas , Implantes Dentários , Masculino , Nanoestruturas/ultraestrutura , Osteoblastos/citologia , Osteoblastos/metabolismo , Próteses e Implantes , Ratos , Propriedades de Superfície
8.
J Colloid Interface Sci ; 564: 8-18, 2020 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-31896426

RESUMO

Surface texture and surface chemistry both are important to design the highly hydrophobic surfaces. Tuning surface chemistry with chemical coating can improve the hydrophobic nature of the surface to a limit. Further increase in hydrophobicity requires an alteration in surface roughness. The present work proposes the randomly distributed nanoscale roughness for designing highly hydrophobic surface engineered particle (SEP) from the hydrophilic particle. An alkali medium is used to engineer the surface of the original particle (OP) for the different time intervals. The surface is thoroughly characterized by Scanning Electron Microscopy, Atomic Force Microscopy, X-Ray Photoelectron Spectroscopy, and contact angle (CA) measurement. Results reveal that the hydrophobic CA up to 147° can be tuned by nanoscale surface roughness even after Si-OH incorporation on the surface. Moreover, the silanization of the OP and SEP surface further identifies that a gradual increase in CA beyond 113° is due to the favorable nano-scale surface roughness and its distribution on the surface of SEP. The study is first of its kind to achieve highly hydrophobic micron-size particle surface (CA ~ 147°) without coating of any low surface energy material.

9.
J Biomater Appl ; 32(6): 813-825, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29160129

RESUMO

This study was aimed at assessing the effects of silica nanopowder incorporation into chitosan-tripolyphosphate microparticles with the ultimate goal of improving their osteogenic properties. The microparticles were prepared by simple coacervation technique and silica nanopowder was added at 0% (C), 2.5% (S1), 5% (S2) and 10% (S3) (w/w) to chitosan. We observed that this simple incorporation of silica nanopowder improved the growth and proliferation of osteoblasts along the surface of the microparticles. In addition, the composite microparticles also showed the increased expression of alkaline phosphatase and osteoblast specific genes. We observed a significant increase ( p < 0.05) in the expression of alkaline phosphatase by the cells growing on all sample groups compared to the control (C) groups at day 14. The morphological characterization of these microparticles through scanning electron microscopy showed that these microparticles were well suited to be used as the injectable scaffolds with perfectly spherical shape and size. The incorporation of silica nanopowder altered the nano-roughness of the microparticles as observed through atomic force microscopy scans with roughness values going down from C to S3. The results in this study, taken together, show the potential of chitosan-tripolyphosphate-silica nanopowder microparticles for improved bone regeneration applications.


Assuntos
Regeneração Óssea , Quitosana/análogos & derivados , Nanopartículas , Alicerces Teciduais , Animais , Células Cultivadas , Camundongos , Osteoblastos/citologia , Dióxido de Silício , Alicerces Teciduais/química
10.
Sci Technol Adv Mater ; 18(1): 197-209, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28469734

RESUMO

Healthcare associated infections (HCAIs) are responsible for substantial patient morbidity, mortality and economic cost. Infection control strategies for reducing rates of transmission include the use of nonwoven wipes to remove pathogenic bacteria from frequently touched surfaces. Wiping is a dynamic process that involves physicochemical mechanisms to detach and transfer bacteria to fibre surfaces within the wipe. The purpose of this study was to determine the extent to which systematic changes in fibre surface energy and nano-roughness influence removal of bacteria from an abiotic polymer surface in dry wiping conditions, without liquid detergents or disinfectants. Nonwoven wipe substrates composed of two commonly used fibre types, lyocell (cellulosic) and polypropylene, with different surface energies and nano-roughnesses, were manufactured using pilot-scale nonwoven facilities to produce samples of comparable structure and dimensional properties. The surface energy and nano-roughness of some lyocell substrates were further adjusted by either oxygen (O2) or hexafluoroethane (C2F6) gas plasma treatment. Static adpression wiping of an inoculated surface under dry conditions produced removal efficiencies of between 9.4% and 15.7%, with no significant difference (p < 0.05) in the relative removal efficiencies of Escherichia coli, Staphylococcus aureus or Enterococcus faecalis. However, dynamic wiping markedly increased peak wiping efficiencies to over 50%, with a minimum increase in removal efficiency of 12.5% and a maximum increase in removal efficiency of 37.9% (all significant at p < 0.05) compared with static wiping, depending on fibre type and bacterium. In dry, dynamic wiping conditions, nonwoven wipe substrates with a surface energy closest to that of the contaminated surface produced the highest E. coli removal efficiency, while the associated increase in fibre nano-roughness abrogated this trend with S. aureus and E. faecalis.

11.
Acta Biomater ; 32: 77-88, 2016 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-26768231

RESUMO

While several scaffolds have been proposed for skeletal muscle regeneration, multiscale hierarchical scaffolds with the complexity of extracellular matrix (ECM) haven't been engineered successfully. By precise control over nano- and microscale features, comprehensive understanding of the effect of multiple factors on skeletal muscle regeneration can be derived. In this study, we engineered carbon-based scaffolds with hierarchical nano- and microscale architecture with controlled physico-chemical properties. More specifically, we built multiscale hierarchy by growing carbon nanotube (CNT) carpets on two types of scaffolds, namely, interconnected microporous carbon foams and aligned carbon fiber mats. Nanostructured CNT carpets offered fine control over nano-roughness and wettability facilitating myoblast adhesion, growth and differentiation into myocytes. However, microporous foam architecture failed to promote their fusion into multinucleated myotubes. On the other hand, aligned fibrous architecture stimulated formation of multinucleated myotubes. Most importantly, nanostructured CNT carpets interfaced with microscale aligned fibrous architecture significantly enhanced myocyte fusion into multinucleated mature myotubes highlighting synergy between nanoscale surface features and micro-/macroscale aligned fibrous architecture in the process of myogenesis. STATEMENT OF SIGNIFICANCE: Due to limited regenerative potential of skeletal muscle, strategies stimulating regeneration of functional muscles are important. These strategies are aimed at promoting differentiation of progenitor cells (myoblasts) into multinucleated myotubes, a key initial step in functional muscle regeneration. Recent tissue engineering approaches utilize various scaffolds ranging from decellularized matrices to aligned biomaterial scaffolds. Although, majority of them have focused on nano- or microscale organization, a systematic approach to build the multiscale hierarchy into these scaffolds is lacking. Here, we engineered multiscale hierarchy into carbon-based materials and demonstrated that the nanoscale features govern the differentiation of individual myoblasts into myocytes whereas microscale alignment cues orchestrate fusion of multiple myocytes into multinucleated myotubes underlining the importance of multiscale hierarchy in enhancing coordinated tissue regeneration.


Assuntos
Diferenciação Celular , Mioblastos/citologia , Nanotubos de Carbono/química , Alicerces Teciduais/química , Animais , Adesão Celular , Linhagem Celular , Proliferação de Células , Forma Celular , Camundongos , Fibras Musculares Esqueléticas/citologia , Mioblastos/metabolismo , Nanotubos de Carbono/ultraestrutura , Molhabilidade
12.
Rev. bras. odontol ; 72(1/2): 92-95, Jan.-Jun. 2015. ilus
Artigo em Português | LILACS | ID: lil-792066

RESUMO

A evolução do projeto dos implantes osseointegráveis é resultado do desenvolvimento de diferentes tipos de estruturas em sua superfície. No entanto, ainda existe a necessidade de estudos para definir o tipo de superfície ideal. Esse trabalho discute métodos de avaliação da superfície de implantes que mostram o potencial de determinadas superfícies para induzir mineralização óssea in vitro, partir do uso de células mesenquimais progenitoras. Foram realizadas análises comparativas entre a topografia de implantes com e sem rugosidades nanométricas e o tipo de interação entre pré-osteoblastos semeados diretamente nesses implantes. Características distintas foram observadas em cada superfície.


Improvements in dental implants structure is the result of development of different types of geometrically intelligent surfaces, provided by the emergence of companies interested in innovation of these materials, however, there is still a need for studies to define the type of ideal surface. This work addresses an unprecedented discussion regarding implant surface evaluation methods, able to show the potential of certain areas to induce bone mineralization in vitro. From the use of mesenchymal progenitor cells, which have the capacity to respond to stimuli surface, comparative tests were performed between the topography implants with and without nano-roughness and the type of functional interaction between pre-osteoblasts seeded directly into these implants. Different characteristics of coating cells and mineralization niches on different surfaces were found.

13.
Nanomedicine (Lond) ; 10(1): 103-19, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25597772

RESUMO

Inspired by natural structures, great attention has been devoted to the study and development of surfaces with extreme wettable properties. The meticulous study of natural systems revealed that the micro/nano-topography of the surface is critical to obtaining unique wettability features, including superhydrophobicity. However, the surface chemistry also has an important role in such surface characteristics. As the interaction of biomaterials with the biological milieu occurs at the surface of the materials, it is expected that synthetic substrates with extreme and controllable wettability ranging from superhydrophilic to superhydrophobic regimes could bring about the possibility of new investigations of cell-material interactions on nonconventional surfaces and the development of alternative devices with biomedical utility. This first part of the review will describe in detail how proteins and cells interact with micro/nano-structured surfaces exhibiting extreme wettabilities.


Assuntos
Materiais Biocompatíveis/química , Materiais Biomiméticos/química , Interações Hidrofóbicas e Hidrofílicas , Nanoestruturas/química , Adsorção , Materiais Biocompatíveis/uso terapêutico , Humanos , Nanoestruturas/uso terapêutico , Proteínas/química , Proteínas/metabolismo , Propriedades de Superfície
14.
Clin Implant Dent Relat Res ; 16(1): 70-80, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22577959

RESUMO

AIM: To assess the effect of platform switching on peri-implant bone remodeling around short implants (8.5 mm) placed in the resorbed posterior mandibular and maxillary region of partially edentulous patients. MATERIALS AND METHODS: Seventeen patients with one or more missing teeth at both sides in the posterior region were, according to a split-mouth design, randomly assigned to be treated with a platform-matched (control) implant on the one side and a platform-switched implant (test) on the other side. A total of 62 short implants (8.5 mm) with a dual-acid etched surface with nanometer-sized calcium phosphate particles was placed. Follow-up visits were conducted one month and one year after placing the implant crown. Outcome measures were interproximal bone level changes, implant survival and clinical parameters. RESULTS: One year after loading, peri-implant bone remodeling around test implants (0.53 ± 0.54 mm) was significant less than around control implants (0.85 ± 0.65 mm; p = .003). With regard to implant survival and clinical parameters no significant differences were observed between test and control implants. CONCLUSIONS: This study suggested that peri-implant bone remodeling is affected by platform switching. One year after loading, interproximal bone levels were better maintained at implants restored according to the platform switching concept.


Assuntos
Remodelação Óssea , Implantação Dentária Endóssea , Implantes Dentários , Condicionamento Ácido do Dente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...