Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Braz J Anesthesiol ; 73(4): 380-384, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-34624376

RESUMO

INTRODUCTION: The evaluation of stroke volume (SV) is useful in research and patient care. To accomplish this, an ideal device should be noninvasive, continuous, reliable, and reproducible. The Mobil-O-Graph (MOG) is a noninvasive oscillometric matrix validated for measuring aortic and peripheral blood pressure, which through conversion algorithms can estimate hemodynamic parameters. OBJECTIVES: To compare the MOG measurement of stroke volume, cardiac output, and cardiac index with the transthoracic echocardiogram (TTE). METHODS: Healthy volunteers aged 18 years or older were included. Two-dimensional TTEs were performed by a single operator. Subsequently, the measurement of noninvasive hemodynamics with MOG was performed with the operator blind to the results of the echocardiogram. Correlation analyses between stroke volume, cardiac output, and cardiac index parameters were performed. The degree of agreement between the methods was verified using the Bland-Altman method. RESULTS: A total of 38 volunteers were enrolled with a mean age of 27.6.ß...ß3.8 years; 21 (55%) were male The SV by TTE was 76.8.ß...ß19.5.ßmL and 75.7.ß...ß19.3.ßmL by MOG, Rho.ß=.ß0.726, p.ß<.ß0.0001. The CO by TTE was 5.04.ß...ß0.8 mL.min-1 and 5.1.ß...ß0.8.ßmL.min-1 by MOG Rho.ß=.ß0.510, p.ß=.ß0.001. Bland-Altman plots showed a good concordance between the two techniques. CONCLUSIONS: Our study shows that the measurement of SV and CO by noninvasive hemodynamics with the MOG device offers a good concordance with the TTE with very few values beyond the confidence limits.


Assuntos
Ecocardiografia , Hemodinâmica , Masculino , Humanos , Adulto , Feminino , Volume Sistólico/fisiologia , Pressão Sanguínea , Ecocardiografia/métodos , Débito Cardíaco/fisiologia , Hemodinâmica/fisiologia
2.
Braz. J. Anesth. (Impr.) ; 73(4): 380-384, 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1447617

RESUMO

Abstract Introduction The evaluation of stroke volume (SV) is useful in research and patient care. To accomplish this, an ideal device should be noninvasive, continuous, reliable, and reproducible. The Mobil-O-Graph (MOG) is a noninvasive oscillometric matrix validated for measuring aortic and peripheral blood pressure, which through conversion algorithms can estimate hemodynamic parameters. Objectives To compare the MOG measurement of stroke volume, cardiac output, and cardiac index with the transthoracic echocardiogram (TTE). Methods Healthy volunteers aged 18 years or older were included. Two-dimensional TTEs were performed by a single operator. Subsequently, the measurement of noninvasive hemodynamics with MOG was performed with the operator blind to the results of the echocardiogram. Correlation analyses between stroke volume, cardiac output, and cardiac index parameters were performed. The degree of agreement between the methods was verified using the Bland-Altman method. Results A total of 38 volunteers were enrolled with a mean age of 27.6 ± 3.8 years; 21 (55%) were male The SV by TTE was 76.8 ± 19.5 mL and 75.7 ± 19.3 mL by MOG, Rho = 0.726, p< 0.0001. The CO by TTE was 5.04 ± 0.8 mL.min-1 and 5.1 ± 0.8 mL.min-1 by MOG Rho = 0.510, p= 0.001. Bland-Altman plots showed a good concordance between the two techniques. Conclusions Our study shows that the measurement of SV and CO by noninvasive hemodynamics with the MOG device offers a good concordance with the TTE with very few values beyond the confidence limits.


Assuntos
Humanos , Masculino , Feminino , Adulto , Ecocardiografia/métodos , Hemodinâmica/fisiologia , Volume Sistólico/fisiologia , Pressão Sanguínea , Débito Cardíaco/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...