1.
Bull Exp Biol Med ; 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38963597

RESUMO

Experimental model of resection craniotomy with subsequent reconstruction of the defect with a polymer implant enables comprehensive assessment of functional and ultrastructural changes during replacement of the damaged tissue. Reconstruction of a skull defect was accompanied by transient motor disturbance in the acute period and did not cause functional disorders and neurological deficits in a delayed period. Histological examination of osteal and brain tissue revealed no pathological reactions that could be associated with the response to the chemical components of the implant.

2.
J Dent ; : 105225, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38969266

RESUMO

OBJECTIVES: To evaluate the fracture resistance (FR) of polyetheretherketone (PEEK) abutments produced by additive and subtractive methods compared to milled zirconia abutments. METHODS: Custom abutments were designed on Ti-base abutments and produced from three different materials, namely additively manufactured PEEK (PEEK-AM), subtractively manufactured PEEK (PEEK-SM), and zirconia (N=60). PEEK-AM abutments were printed using PEEK filaments (VESTAKEEP®i4 3DF-T, Evonik Industries AG) on a M150 Medical 3D Printer (ORION AM) by fused filament fabrication (FFF). All surface treatments were carried out according to the manufacturer's instructions. All abutments were cemented on Ti-bases with hybrid abutment cement and then restored with milled zirconia crowns. Each subgroup was divided into non-aged and aged subgroups (n=10). The aged groups were subjected to thermomechanical aging (49 N, 5-55°C, 1.2 million cycles). FR tests were performed by using a universal testing machine. Data were statistically analyzed with one-way and two-way ANOVA and t-test. RESULTS: The survival rate of the specimens after aging was determined as 100%. It was found that both the material and aging had a significant effect on the FR (p<.001). There was a statistical difference among the fracture values of the groups (p<0.001). In both the aged and non-aged groups, PEEK-AM showed the statistically lowest FR, while the highest FR was seen in the zirconia group, which was significantly higher than the PEEK-SM (p<0.001). CONCLUSION: Hybrid abutments were successfully manufactured, and extrusion-based processed PEEK seems to be a good alternative to subtractive processed PEEK. However, since subtractive manufacturing still appears to be superior, further developments in additive manufacturing are needed to further improve the quality of 3D-printed PEEK parts, especially in terms of accuracy and bonding between adjacent layers. CLINICAL SIGNIFICANCE: Additively manufactured PEEK abutments have the potential to be an alternative for implant-supported restorations in the posterior region.

3.
Int J Spine Surg ; 18(3): 287-294, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38960609

RESUMO

BACKGROUND: Anterior cervical discectomy and fusion (ACDF) for the surgical treatment of cervical degenerative disease often includes an intervertebral cage, which restores disc height and lordosis while promoting fusion . Cage materials include titanium (TTN) or polyetheretherketone (PEEK). Controversy in material selection stems from higher fusion rates with TNN, despite a higher subsidence rate, while PEEK cages demonstrate superior preservation of interspace height. Combining the advantages of both materials, TTN-coated PEEK (TCPEEK) cages were developed, featuring a PEEK core with similar stiffness to the bone, enveloped with a TTN coat, improving osteointegration. However, the potential superiority of TCPEEK over TTN cages has not been investigated. This study aimed to compare clinical and radiographic outcomes following single- or double-level ACDF using either TTN or TCPEEK cages. METHODS: This retrospective single-center study included patients undergoing single- or double-level ACDF between 2017 and 2019. Clinical outcomes included the Neck Disability Index and revision surgery incidence. Radiographic parameters included cervical and segmental lordosis, C2 to C7 sagittal vertical axis, fusion, subsidence, and adjacent segment degeneration at a minimum 12-month follow-up. RESULTS: A total of 45 patients (16 TTN; 29 TCPEEK) and 58 cervical levels (21 TTN; 37 TCPEEK) were included. Both cages significantly improved Neck Disability Index scores (TTN -10.0; TCPEEK -14.1) without significant differences. Two single-level TCPEEK patients required revision surgery due to non-union. In the radiological assessments, no significant difference was found for subsidence rates (TTN 52.4%; TCPEEK 56.8%), adjacent segment degeneration, cervical and segmental lordosis, and changes in C2 to C7 sagittal vertical axis. Though not statistically significant, fusion rates trended slightly higher with TTN (90.5%) vs TCPEEK cages (86.5%). CONCLUSION: TTN and TCPEEK cages achieve satisfactory clinical and radiological outcomes in single- or double-level ACDF. This finding suggests that the choice between them can be based on other factors, such as surgeon preference or availability, rather than specific material properties. CLINICAL RELEVANCE: This study found that the selection of ACDF cage material did not affect clinical outcomes.

4.
Dent J (Basel) ; 12(6)2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38920889

RESUMO

This in vitro study assessed the effect of different primers on the shear bond strength (SBS) and adhesive remnant index (ARI) of orthodontic brackets bonded to reinforced polyetheretherketone (PEEK) substrate. A total of 40 specimens were randomly distributed to two groups based on the primer used for orthodontic bonding: group 1 (control)-Transbond XT adhesive with Visio.link primer and group 2 (test)-orthodontic adhesive (Transbond XT) with traditional orthodontic primer. After bonding, specimens were thermocycled followed by SBS testing and ARI scoring of debonded specimens. Data were analyzed using the unpaired independent t-test and the Chi-square test. Group 1 specimens showed significantly higher SBS values (21.38 ± 1.48 MPa) compared to group 2 specimens (18.63 ± 1.29 MPa) (p < 0.0001). Adhesive remnant index scores showed no significant variations in bond failure modes and distributions between groups. The SBS obtained by the tested primers exceeded the clinically recommended value. Consequently, there is a comparable clinical application for both tested primers in orthodontic bonding, especially the traditional orthodontic primer, where the availability of Visio.link in clinical practice is not ensured.

5.
Int J Biol Macromol ; 274(Pt 2): 133435, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38936580

RESUMO

Polyether-ether-ketone (PEEK) is clinically used as a bio-implant for the healing of skeletal defects. However, the osseointegration of clinical-sized bone grafts remains limited. In this study, surface-porous PEEK was created by using a sulfonation method and a metal-polysaccharide complex MgCS was introduced on the surface of sulfonated PEEK to form MgCS@SPEEK. The as-prepared MgCS@SPEEK was found to have a porous surface with good hydrophilicity and bioactivity. This was followed by an investigation into whether MgCS loaded onto sulfonated PEEK surfaces could promote osseointegration and angiogenesis. The in vitro results showed that MgCS@SPEEK had a positive effect on reducing the expression levels of inflammatory genes and promoting osteogenesis and angiogenesis-related genes expression levels. Furthermore, porous MgCS@SPEEK was implanted in critical-sized rat tibial defects for in vivo evaluation of osseointegration. The micro-computed tomography evaluation results revealed substantial bone formation at 4 and 8 weeks. Collectively, these findings indicate that MgCS@SPEEK could provide improved osseointegration and an attractive strategy for orthopaedic applications.

6.
Comput Biol Med ; 178: 108708, 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38861895

RESUMO

BACKGROUND: High-performance polymers are used in different fixed prosthesis treatments due to their many advantages such as biocompatibility, shock absorption ability, high fracture resistance. The effects of marginal design on the forces on high-performance polymers are unknown. This study aimed was to investigate the stress distribution of different marginal designs on Polyetheretherketone (PEEK) and Polyetherketoneketone (PEKK) substructure materials, cortical bone and cancellous bone by finite element analysis. METHODS: A first maxillary molar tooth was modeled in 3D using the "3D Complex Render" method. Considering the ideal preparation conditions (Taper angle was 6°, step depth was 1 mm, occlusal reduction was 2 mm), four different configurations were modeled by changing the marginal design (chamfer, deep chamfer, shoulder 90°, shoulder 135°). PEEK, PEKK substructure, and composite superstructure were designed on created models. A total of 150 N oblique force from two points and a total of 300 N vertical force from three points were applied from occlusall. and the maximum principal stress, minimum principal stress, von Mises stress findings in the cortical bone, spongiose bone, and substructure were examined. The study was carried out by static linear analysis with a three-dimensional finite element stress analysis method. RESULTS: The highest maximum principal stress value in the cortical bone was observed when the PEEK + Shoulder 135° step at vertical force. The highest minimum principal stress value in the cortical bone was observed when the PEEK + Shoulder 90° step, and PEEK + deep chamfer step at oblique force. The highest maximum principal stress value in spongiose bone was observed when the PEEK + Shoulder 90° step. The highest minimum principal stress value in spongiose bone was observed when the PEEK + deep chamfer step at vertical force. The highest von Mises stress value in the substructure was observed when the PEKK + Deep chamfer step at oblique force. The lowest maximum principal stress value in the cortical bone was observed when the PEKK + Shoulder 135° step at oblique force. The lowest minimum principal stress value in the cortical bone was observed when the PEEK + Shoulder 135° step, and PEKK + shoulder 135° step at vertical force. The lowest maximum principal stress value in spongiose bone was observed when the PEEK + Shoulder 90° step. The lowest minimum principal stress value in spongiose bone was observed when the PEEK + Shoulder 135° step and PEKK + Shoulder 135° step at vertical force. The lowest von Mises stress value in the substructure was observed when the PEEK + Deep chamfer step at vertical force. CONCLUSION: When cortical and spongiose bone stress were evaluated, no destructive stress was observed. Considering the stresses occurring in the substructure the highest stress was observed in the chamfer step.

7.
World Neurosurg X ; 23: 100392, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38884030

RESUMO

Background: A wide variety of materials are used for lumbar interbody fusion, but there is no unified consensus on the superiority of one material over another. The aim of this systematic review and network meta-analysis (NMA) is to compare and rank the various TLIF interbody materials based on fusion rates. Methods: We queried PubMed, EMBASE and Scopus from inception until August 2023, in which 2135 studies were identified. Inclusion criteria were applied based on the PRISMA guidelines. The fusion assessment employed the Bridwell's criteria with a length of follow-up of at least 12 months. The NMA was conducted to compare multiple approaches from multiple studies using the frequentist framework with STATA16. Results: In total, 13 TLIF studies involving 1919 patients with 1981 lumbar interbody levels fulfilled our eligibility criteria. Seven different cage materials were utilized: polyetheretherketone (PEEK, as the reference), allograft, autograft, PEEK with titanium coating (TiPEEK), titanium, carbon/carbon fiber reinforced polymer (CFRP) and 3D-printed titanium. The average patient age was 60.9 (SD = 7.5) years old. When compared to PEEK, the other six materials did not have a significantly different rate of lumbar fusion. However, the SUCRA number of the 3D-printed titanium, TiPEEK, Ti, allograft, autograft, CFRP, and PEEK were 0.8, 0.6, 0.5, 0.5, 0.4, 0.4, and 0.3 consecutively. Conclusions: Based on a network meta-analysis within the confines of our clinical study, 3D-printed titanium interbody cage may promote the highest success rate of fusion while PEEK may be the material with the least success rate of fusion in TLIF.

8.
Sultan Qaboos Univ Med J ; 24(2): 250-258, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38828246

RESUMO

Objectives: Cranioplasty is a complex craniofacial and neurosurgical procedure that aims to reinstate the architecture of the cranial vault and elevate both its aesthetic and neurological function. Several reconstructive materials have been thoroughly explored in the search for the optimal solution for cranioplasty. This study aimed to evaluate different material used for cranial reconstruction in Oman. Methods: This retrospective study included all patients who had had cranioplasty procedures performed at Khoula Hospital, Muscat, Oman, from 2012 to 2022. Demographic information, the characteristics of the cranial defect and any complications that occurred post-operatively were analysed. Results: A total of 47 patients were included in this study. The most common cause of cranial defects was craniectomy following traumatic head injury (70.2%) along with excision of fibrous dysplasia (10.6%). The most frequently utilised material for cranial repair was autologous bone grafts (n = 28), followed by polyetheretherketone (PEEK; n = 14). Interestingly, the replacement of bone grafts from previous craniectomy showed a notably high resorption rate (71.4%), in contrast to split calvarial grafts (0%) and other types of bone grafts (14.3%). Additionally, delayed graft infection was observed in 3.6% of the bone graft group and 7.1% of the PEEK group. Conclusion: Patient-specific alloplastic implants such as PEEK have gained popularity for large and complex cranioplasty, as they provide excellent aesthetic outcomes and leave no donor site morbidity. In contrast, bone grafts remain the gold standard for small to medium-sized cranial defects.


Assuntos
Procedimentos de Cirurgia Plástica , Humanos , Omã/epidemiologia , Estudos Retrospectivos , Masculino , Feminino , Adulto , Procedimentos de Cirurgia Plástica/métodos , Procedimentos de Cirurgia Plástica/estatística & dados numéricos , Pessoa de Meia-Idade , Adolescente , Crânio/cirurgia , Criança , Transplante Ósseo/métodos , Transplante Ósseo/estatística & dados numéricos , Polímeros/uso terapêutico , Benzofenonas , Idoso , Pré-Escolar
9.
J Oral Implantol ; 50(3): 220-230, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38839068

RESUMO

This study analyzed the stress distributions on zygomatic and dental implants placed in the zygomatic bone, supporting bones, and superstructures under occlusal loads after maxillary reconstruction with obturator prostheses. A total of 12 scenarios of 3-dimensional finite element models were constructed based on computerized tomography scans of a hemimaxillectomy patient. Two obturator prostheses were analyzed for each model. A total force of 600 N was applied from the palatal to buccal bones at an angle of 45°. The maximum and minimum principal stress values for bone and von Mises stress values for dental implants and prostheses were calculated. When zygomatic implants were applied to the defect area, the maximum principal stresses were similar in intensity to the other models; however, the minimum principal stress values were higher than in scenarios without zygomatic implants. In models that used zygomatic implants in the defect area, von Mises stress levels were significantly higher in zygomatic implants than in dental implants. In scenarios where the prosthesis was supported by tissue in the nondefect area, the maximum and minimum principal stress values on cortical bone were higher than in scenarios where implants were applied to defect and nondefect areas. In patients who lack an alveolar crest after maxillectomy, a custom bar-retained prosthesis placed on the dental implant should reduce stress on the zygomatic bone. The stress was higher on zygomatic implants without alveolar crest support than on dental implants.


Assuntos
Implantes Dentários , Análise de Elementos Finitos , Maxila , Obturadores Palatinos , Zigoma , Humanos , Zigoma/cirurgia , Maxila/cirurgia , Imageamento Tridimensional , Análise do Estresse Dentário , Força de Mordida , Fenômenos Biomecânicos , Simulação por Computador , Estresse Mecânico , Osso Cortical , Tomografia Computadorizada por Raios X , Implantação Dentária Endóssea/métodos , Prótese Dentária Fixada por Implante
10.
J Stomatol Oral Maxillofac Surg ; : 101939, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38851587

RESUMO

AIM: The study was conducted to evaluate soft tissue profile changes using autogenous fat augmentation or onlay PEEK versus sliding genioplasty for correction of deficient chin in patients with retruded chin. MATERIAL AND METHODS: Thirty-three patients with deficient chins were included in the study. The patients were distributed into 3 groups: the fat augmentation group as intervention I, the PEEK augmentation group as intervention II, and the osseous genioplasty group as control group. Preoperative and postoperative CBCT were performed for all patients. With the aid of MIMICS,3-MATIC, and PROPLAN software, diagnosis, virtual planning, and evaluation were performed. The Face-Q questionnaire was used to assess patient satisfaction. RESULTS: There was a statistically significant difference regarding soft tissue relapse in the fat group after 6 months when compared to the control group (mean difference= 0.770), while there was no statistically significant difference regarding soft tissue relapse between PEEK and control group (mean difference= -0.060). Intragroup comparison has shown no statistically significant difference regarding soft tissue relapse within all groups between follow-up periods (P = 0.1389 for the fat group, P = 0.8739 for the peek group, and P = 0.8410 for the control group). All patients showed a statistically significant increase in scores of satisfaction with the chin between follow-up periods (P = 0.0165, P = 0.0150, and P = 0.0293) respectively. CONCLUSIONS: Fat augmentation can be a good intervention choice in mild-moderate deficient cases. PEEK PSI has a stable surgical outcome.

11.
Dent Mater ; 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38824001

RESUMO

OBJECTIVE: Achieving a strong bond between Polyetheretherketone (PEEK) and veneering composites is challenging due to PEEKs low surface energy. This study examined the effects of sandblasting and bonding on the shear bond strength (SBS) between veneering composite and pigmented PEEK, considering artificial aging. METHODS: Of three pigmented PEEK compounds (DC4420R, DC4450R, DC4470R; Evonic Operations GmbH, Marl, Germany), 40 specimens each were milled and polished up to 2500 grit. Prior to veneering, specimens were divided into 4 subgroups: Subgroup 1: Polishing; 2: Polishing + bonding; 3: Sandblasting; 4: Sandblasting + bonding. Sandblasting was performed using Al2O3. Adhesive was an agent containing MMA (Signum Universal Bond, Kulzer GmbH, Hanau, Germany). After veneering (Composite, Kulzer GmbH) the subgroups were divided into 2 subgroups. One subgroup was immersed in 37 °C warm distilled water for 24 h. The second subgroup was artificially aged by thermocycling (TCL) with 5000 cycles in distilled water (5 °C / 55 °C; 30 s). Surface roughness, water contact angles and failure modes were recorded. SBS was measured using a universal testing machine. RESULTS: Results demonstrated that the combination of sandblasting and bonding significantly improved the SBS compared to polishing alone. PEEK color did not significantly influence the SBS. Aging by TCL had a negative effect on the SBS. SIGNIFICANCE: Sandblasting and the use of an adhesive containing MMA were found to be effective in achieving satisfactory SBS between veneering composite and pigmented PEEK surfaces. These pretreatment methods demonstrate their potential for establishing durable and reliable bonding in clinical applications.

12.
BMC Musculoskelet Disord ; 25(1): 488, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38909212

RESUMO

PURPOSE: To analyze the characteristics of PEEK rods retrieved in vivo, specifically their wear and deformation, biodegradability, histocompatibility, and mechanical properties. METHOD: Six PEEK rods were retrieved from revision surgeries along with periprosthetic tissue. The retrieved PEEK rods were evaluated for surface damage and internal changes using Micro-CT, while light and electron microscopy were utilized to determine any histological changes in periprosthetic tissues. Patient history was gathered from medical records. Two intact and retrieved PEEK rods were used for fatigue testing analysis by sinusoidal load to the spinal construct. RESULTS: All implants showed evidence of plastic deformation around the screw-rod interface, while the inner structure of PEEK rods appeared unchanged with no visible voids or cracks. Examining images captured through light and electron microscopy indicated that phagocytosis of macrophages around PEEK rods was less severe in comparison to the screw-rod interface. The results of an energy spectrum analysis suggested that the distribution of tissue elements around PEEK rods did not differ significantly from normal tissue. During fatigue testing, it was found that the retrieved PEEK rods cracked after 1.36 million tests, whereas the intact PEEK rods completed 5 million fatigue tests without any failure. CONCLUSION: PEEK rods demonstrate satisfactory biocompatibility, corrosion resistance, chemical stability, and mechanical properties. Nevertheless, it is observed that the indentation at the junction between the nut and the rod exhibits relatively weak strength, making it susceptible to breakage. As a precautionary measure, it is recommended to secure the nut with a counter wrench, applying the preset torque to prevent overtightening.


Assuntos
Benzofenonas , Cetonas , Parafusos Pediculares , Polímeros , Humanos , Cetonas/química , Feminino , Masculino , Polietilenoglicóis/química , Pessoa de Meia-Idade , Remoção de Dispositivo , Teste de Materiais , Idoso , Materiais Biocompatíveis , Falha de Prótese , Reoperação
13.
Int J Oral Maxillofac Implants ; 0(0): 1-17, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38941169

RESUMO

PURPOSE: The aim of this study is to examine the stresses on the peri-implant bone under occlusal forces of 30% Carbon fiber reinforced PEEK (Cfr-PEEK) and 60% Cfr-PEEK materials that can be used as an alternative to titanium dental implants by finite element analysis. MATERIALS AND METHODS: Single-tooth implants of 30% Cfr-PEEK, 60% Cfr-PEEK and titanium were modeled in each of the maxillary anterior, maxilla posterior, mandibular posterior regions. As a result of the applied vertical and oblique forces; Von Misses stress, maximum principal stress and minimum principal stress values and stress distributions in the implant, cortical bone and spongious bone in each of the models were examined. RESULTS: 30% Cfr-PEEK implants stress in the surrounding bone was higher than titanium and 60% Cfr-PEEK implants. The 60% Cfr-PEEK material displayed lower stress distribution on both cortical and spongious peri-implant bone in all models. CONCLUSION: Titanium and 60% Cfr- PEEK implants exhibited biomechanically similar behavior and these implants conducted stresses to bone more homogeneous than the 30% Cfr-PEEK implants. Overall, oblique forces had more destructive effect than vertical forces and denser bone structure showed better stress distribution against incoming forces. For the routine use of Cfr-PEEK material as dental implant material; animal and long-term clinical studies are needed.

14.
Materials (Basel) ; 17(12)2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38930269

RESUMO

The interfacial properties between carbon fiber (CF) and thermoplastic resin are relatively weak, which can be problematic for composites in structural applications. Improving the surface roughness of CF is regarded as an effective way to enhance the interface of composites. However, most CF modifying methods are complex and time-consuming, which cannot meet the demand for industrial production. Therefore, it is of great significance to research a fast technique of CF surface modification to strengthen the interface of composites. Herein, a one-pot reaction based on the aryl diazonium salt modification was applied to enhance the interface between CF and poly ether ether ketone (PEEK) resin. Carbon nanotubes (CNTs) were linked to CF by p-phenylenediamine (PPD) via cyclic voltammetry (CV). The surface morphology, chemical characteristics and surface energy of modified CF illustrated the effectiveness of this method, and the interfacial properties of as-prepared modified CF/PEEK demonstrated the increased tendency. All the CF was treated within 5 min and the interfacial shear strength (IFSS) of CF/PEEK was increased to the maximum of 99.62 MPa by aryl diazonium salt modification. This work may shed some light on the industrialized application of CF reinforced high-performance engineering thermoplastic composites.

15.
Micromachines (Basel) ; 15(6)2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38930771

RESUMO

Substrate materials for printed circuit boards must meet ever-increasing requirements to keep up with electronics technology development. Especially in the field of high-frequency applications such as radar and cellular broadcasting, low permittivity and the dielectric loss factor are key material parameters. In this work, the dielectric properties of a high-temperature, thermoplastic PEEK/PEI blend system are investigated at frequencies of 5 and 10 GHz under dried and ambient conditions. This material blend, modified with a suitable filler system, is capable of being used in the laser direct structuring (LDS) process. It is revealed that the degree of crystallinity of neat PEEK has a notable influence on the dielectric properties, as well as the PEEK phase structure in the blend system developed through annealing. This phenomenon can in turn be exploited to minimize permittivity values at 30 to 40 wt.-% PEI in the blend, even taking into account the water uptake present in thermoplastics. The dielectric loss follows a linear mixing rule over the blend range, which proved to be true also for PEEK/PEI LDS compounds.

16.
J Mech Behav Biomed Mater ; 156: 106581, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38776740

RESUMO

Patient-specific fabrication of scaffold/implant requires an engineering approach to manufacture the ideal scaffold. Herein, we design and 3D print scaffolds comprised of polyether-ether-ketone (PEEK) and sodium-carboxymethyl cellulose (Na-CMC). The fabricated scaffold was dip coated with Zn and Mn doped bioactive glass nanoparticles (Zn-Mn MBGNs). The synthesized ink exhibit suitable shear-thinning behavior for direct ink write (DIW) 3D printing. The scaffolds were crafted with precision, featuring 85% porosity, 0.3 mm layer height, and 1.5 mm/s printing speed at room temperature. Scanning electron microscopy images reveal a well-defined scaffold with an average pore size of 600 ± 30 µm. The energy dispersive X-ray spectroscopy analysis confirmed a well dispersed/uniform coating of Zn-Mn MBGNs on the PEEK/Na-CMC scaffold. Fourier transform infrared spectroscopy approved the presence of PEEK, CMC, and Zn-Mn MBGNs. The tensile test revealed a Young's modulus of 2.05 GPa. Antibacterial assays demonstrate inhibition zone against Staphylococcus aureus and Escherichia Coli strains. Chick Chorioallantoic Membrane assays also present significant angiogenesis potential, owing to the antigenic nature of Zn-Mn MBGNs. WST-8 cell viability assays depicted cell proliferation, with a 103% viability after 7 days of culture. This study suggests that the PEEK/Na-CMC scaffolds coated with Zn-Mn MBGNs are an excellent candidate for osteoporotic fracture treatment. Thus, the fabricated scaffold can offer multifaceted properties for enhanced patient outcomes in the bone tissue regeneration.


Assuntos
Benzofenonas , Carboximetilcelulose Sódica , Vidro , Cetonas , Manganês , Nanopartículas , Polietilenoglicóis , Polímeros , Impressão Tridimensional , Staphylococcus aureus , Alicerces Teciduais , Zinco , Porosidade , Benzofenonas/química , Vidro/química , Cetonas/química , Cetonas/farmacologia , Alicerces Teciduais/química , Staphylococcus aureus/efeitos dos fármacos , Carboximetilcelulose Sódica/química , Nanopartículas/química , Zinco/química , Zinco/farmacologia , Polímeros/química , Manganês/química , Polietilenoglicóis/química , Antibacterianos/química , Antibacterianos/farmacologia , Animais , Escherichia coli/efeitos dos fármacos , Teste de Materiais , Humanos
17.
Artigo em Inglês | MEDLINE | ID: mdl-38756021

RESUMO

The aim of this research was to evaluate the stress distribution in the 'All-on-Four' prosthesis and the surrounding bone, with different framework materials and thicknesses. Five frameworks (alumina, zirconia, titanium, fiberglass reinforced resin (FRR), and polyether ether ketone (PEEK)) with two thicknesses (3.5 &5.5 mm) were stimulated in this research. A vertical force of 200 N was applied on a 1 mm circular area, at the cantilever, and at the region of the incisors, simulating different mastication mechanisms. The results illustrated that the 5.5 mm framework reduced the stresses on most parts, mucosa, and bone tissues, compared to 3.5 mm.

18.
Polymers (Basel) ; 16(9)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38732740

RESUMO

Polyetheretherketone (PEEK), an organic thermoplastic polymer, has gained interest in dentistry due to its excellent mechanical strength, flexibility, and biocompatibility. Furthermore, the ability to utilize CAD/CAM in the fabrication of PEEK enhances accuracy, reliability, and efficiency while also saving time. Hence, several orthodontic studies have explored the utilization of PEEK in various applications, such as archwires, brackets, fixed lingual retainers, palatal expansion devices, transpalatal arches, Tübingen palatal plates, different types of space maintainers, mini-implant insertion guides, and more. However, a complete systematic review of the available data comparing the performance of PEEK with traditional orthodontic materials has not yet been conducted. Therefore, this systematic review seeks to assess if PEEK material meets the required mechanical criteria to serve as an alternative to conventional orthodontic appliances. To ensure clarity and precision, this review will specifically concentrate on fixed appliances. This systemic review followed the PRISMA guidelines and utilized databases including PubMed/MEDLINE, Embase, Springer, Web of Science, and Wiley. Searches were restricted to English language articles from January 2013 to February 2024. Keywords such as "Polyetheretherketone" or "PEEK" and "Orthodontic" or "Orthodontic device" or "Orthodontic materials" were employed across all databases. Nine studies were incorporated, covering orthodontic archwires, brackets, and fixed lingual retainers. Based on the reviewed literature, PEEK demonstrates promising potential in orthodontic fixed appliances, offering advantages in force delivery, friction reduction, and aesthetic appeal. Further research is needed to fully explore its capabilities and optimize its application in clinical practice.

19.
Sci Rep ; 14(1): 10351, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38710929

RESUMO

Additive manufacturing of conductive layers on a dielectric substrate has garnered significant interest due to its promise to produce printed electronics efficiently and its capability to print on curved substrates. A considerable challenge encountered is the conductive layer's potential peeling due to inadequate adhesion with the dielectric substrate, which compromises the durability and functionality of the electronics. This study strives to facilitate the binding force through dielectric substrate surface modification using concentrated sulfuric acid and ultraviolet (UV) laser treatment. First, polyetheretherketone (PEEK) and nanoparticle silver ink were employed as the studied material. Second, the surface treatment of PEEK substrates was conducted across six levels of sulfuric acid exposure time and eight levels of UV laser scanning velocity. Then, responses such as surface morphology, roughness, elemental composition, chemical bonding characteristics, water contact angle, and surface free energy (SFE) were assessed to understand the effects of these treatments. Finally, the nanoparticle silver ink layer was deposited on the PEEK surface, and the adhesion force measured using a pull-off adhesion tester. Results unveiled a binding force of 0.37 MPa on unmodified surface, which escalated to 1.99 MPa with sulfuric acid treatment and 2.21 MPa with UV laser treatment. Additionally, cross-approach treatment investigations revealed that application sequence significantly impacts results, increasing binding force to 2.77 MPa. The analysis further delves into the influence mechanism of the surface modification on the binding force, elucidating that UV laser and sulfuric acid surface treatment methods hold substantial promise for enhancing the binding force between heterogeneous materials in the additive manufacturing of electronics.

20.
J Prosthodont ; 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38807201

RESUMO

PURPOSE: This study compared the fracture strength of single lithium disilicate implant-supported crowns fabricated on two-piece abutments with various materials: ceramic-reinforced PEEK, zirconia, and lithium disilicate. MATERIALS AND METHODS: Thirty-six implants were embedded in acrylic cylinders. A two-piece abutment and a crown were designed following a pre-operation scan for a maxillary left central incisor. The designed crown was used to fabricate 36 lithium disilicate crowns. The designed abutment was used to manufacture 36 abutments from 3 materials, 12 each: (A) zirconia; (B) lithium disilicate; and (C) ceramic-reinforced PEEK. Abutments were surface treated and bonded on the titanium base abutments with resin cement. Then, lithium disilicate crowns were bonded on the assigned abutments. Specimens were then subjected to dynamic loading for 1,200,000 cycles. The fracture strength (N) of the assembly was assessed using a universal testing machine. One-way ANOVA followed by multiple comparison tests was used to evaluate the effect of abutment material on the fracture strength of single implant-supported restorations at a significance of .05. RESULTS: The average fracture strength for the groups with zirconia, PEEK, and lithium disilicate two-piece abutments were 1362N ± 218N, 1235N ± 115N, and 1472N ± 171N, respectively. There was a significant (p < 0.05) difference in fracture strength among the groups. The lithium disilicate group had significantly higher fracture strength (p = 0.0058) than the group with PEEK; however, there was no significant (p > 0.05) difference between the other groups. CONCLUSIONS: Two-piece abutments restored with lithium disilicate crowns investigated in the study have the potential to withstand the average physiological occlusal forces in the anterior region.