1.
Catheter Cardiovasc Interv ; 90(4): 650-659, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-28109043

RESUMO

OBJECTIVES: We sought to investigate a new angiographic method for aortic regurgitation (AR) severity assessment in the setting of transcatheter aortic valve implantation (TAVI). BACKGROUND: AR after TAVI is common but challenging to quantitate, especially in the cath-lab. METHODS: In 228 patients, AR was quantitated before and after TAVI by echocardiography and by video-densitometric analysis of aortograms. Contrast time-density curves for the aortic root (the reference region) and the left ventricular outflow tract, LVOT were generated. LVOT-AR was calculated as the area under the curve of the LVOT as a fraction of the area under the curve of the reference region. RESULTS: LVOT-AR was 0.10 ± 0.08, 0.13 ± 0.10 and 0.28 ± 0.14 in none-trace, mild and moderate-severe post-TAVI AR as defined by echocardiography (P < 0.001) and a cutpoint of >0.17 corresponded to moderate-severe AR on echocardiography (area under the curve = 0.84). At follow-up (median, 496 days), patients with LVOT-AR ≤ 0.17 showed a significant reduction of LV mass index (LVMi; 121 [95-148] vs. 140 [112-169] g/m2 , P = 0.009) and the prevalence of LV hypertrophy (LVH; 64 vs. 88%, P = 0.001) compared to baseline. In patients with LVOT-AR > 0.17, LVMi (149 [121-178] vs. 166 [144-188] g/m2 , P = 0.14) and the prevalence of LVH (74 vs. 87%, P = 0.23) did not show a significant change. Compared to patients with LVOT-AR ≤ 0.17, those with LVOT-AR > 0.17 had an increased 30-day (16.4% vs. 7.1%, P = 0.035) and one year mortality (32.9 vs. 14.2%, log rank P value = 0.001; HR: 2.690 [1.461-4.953], P = 0.001). CONCLUSIONS: LVOT-AR > 0.17 corresponds to greater than mild AR as defined by echocardiography and predicts impaired LV reverse remodeling and increased early and midterm mortality after TAVI. © 2017 Wiley Periodicals, Inc.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Aortografia/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Área Sob a Curva , Brasil , Densitometria , Ecocardiografia Doppler em Cores , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Curva ROC , Sistema de Registros , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA