Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 110
Filtrar
1.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 41(3): 627-634, 2024 Jun 25.
Artigo em Chinês | MEDLINE | ID: mdl-38932551

RESUMO

The simultaneous objectives of destroying tumor cells while protecting normal pelvic organs present a dual clinical and technical challenge within the realm of pelvic tumor radiotherapy. This article reviews the latest literatures, focusing on technological innovations in key aspects of radiotherapy such as positioning, planning, and delivery. These include positioning fixation techniques, organ-at-risk avoidance irradiation, non-coplanar irradiation techniques, as well as organ displacement protection and image-guided adaptive techniques. It summarizes and discusses the research progress made in the protection of critical organs during pelvic tumor radiotherapy. The paper emphasizes technological advancements in the protection of critical organs throughout the processes of radiotherapy positioning, planning, and implementation, aiming to provide references for further research on the protection of critical organs in the external irradiation treatment of pelvic tumors.


Assuntos
Órgãos em Risco , Neoplasias Pélvicas , Humanos , Neoplasias Pélvicas/radioterapia , Órgãos em Risco/efeitos da radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Posicionamento do Paciente , Pelve/efeitos da radiação , Radioterapia/métodos , Radioterapia/efeitos adversos , Proteção Radiológica/métodos , Lesões por Radiação/prevenção & controle
2.
Artigo em Inglês | MEDLINE | ID: mdl-38836905

RESUMO

PURPOSE: Acetabular reconstruction in situ after extensive pelvic resection is technically challenging. The aim of this study was to investigate the feasibility of positioning guiders for acetabular reconstruction following pelvic tumor resection and the clinical benefit brought by the approach. METHODS: The study included patients who underwent acetabular reconstruction following periacetabular tumor resection using a modular hemipelvic prosthesis. In the guider-assisted group (n = 14), guiders were designed and applied to assist acetabular reconstruction. In the traditional operation group (n = 18), the patients underwent the same surgery but without the guiders. The displacement of the hip rotation center before and after surgery was calculated. The complications and the Musculoskeletal Tumor Society-93 scores were documented. RESULTS: The overall displacement of the hip rotation center was significantly reduced in the guider-assisted group compared with the traditional operation group (13.83 ± 4.06 vs. 22.95 ± 9.18 mm in P = 0.000, 95%CI 3.90-12.96), especially in the anteroposterior axis (3.77 ± 3.03 versus 13.51 ± 9.43 mm in P = 0.000, 95%CI 3.45-13.09). Guider-assisted acetabular reconstruction reduced the risk of prosthesis dislocation compared with the traditional operation (dislocation risks: 1/14, 7.1% vs. 4/18, 22.2%). CONCLUSION: Positioning guiders can effectively and conveniently help place the modular hemipelvic prosthesis at the native position, which might potentially reduce the risk of prosthesis dislocation. LEVEL OF EVIDENCE: Therapeutic level III.

3.
Ther Adv Urol ; 16: 17562872241249603, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38779495

RESUMO

Bladder paraganglioma is a rare neuroendocrine neoplasm, either functional or non-functional, arising from the urinary bladder. Functional variants present with catecholamine-related symptoms, while non-functional variants pose diagnostic challenges, mimicking urothelial carcinoma. Misdiagnosis risks underscore the importance of accurate identification for appropriate patient management. In this case, a 52-year-old man, diagnosed incidentally with hypertension and reported occasional post-micturition tachycardia, underwent abdominal ultrasound for known hepatic cyst follow-up, revealing an oval hypoechoic bladder mass. Initial consideration of bladder urothelial carcinoma prompted further investigation with contrast-enhanced CT scan and cystoscopy that confirmed extrinsic mass nature, and subsequent robotic-assisted partial cystectomy was performed. Histologically, the removed mass exhibited characteristic features of bladder paraganglioma. Postoperative recovery was uneventful, with resolution of post-micturition tachycardia at 1 month. Follow-up includes endocrinological evaluation and a 6-month CT scan. In conclusion, bladder paraganglioma should be considered in para-vesical mass differentials. This case highlights the importance of meticulous history collection, even in asymptomatic patients, the need for a multidisciplinary approach for accurate diagnosis and management of this rare condition, and the robotic approach as a viable option.

5.
Cureus ; 15(9): e45661, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37868403

RESUMO

Giant cell tumors (GCTs) of the ischium are rare and often diagnosed at an advanced stage. In fact, there is no defined treatment algorithm to treat this lesion. We present two case reports of Campanacci's stage three ischiopubic GCT confirmed with biopsy. They were effectively treated with excision of the ischiopubic ramus, aggressive curettage, drilling, and phenolization at the margins. The surgery was performed in a gynecological position with an approach over the ischiopubic ramus. Both cases present no recurrence (two and 10-year follow-up), and neither has a significant impact on the quality of life. A thorough plan and surgical technique were essential for the success of this intervention.

6.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 37(10): 1183-1189, 2023 Oct 15.
Artigo em Chinês | MEDLINE | ID: mdl-37848311

RESUMO

Objective: To investigate the effectiveness of three-dimensional (3D)-printed hemi-pelvic prosthesis for revision of aseptic loosening or screw fracture of modular hemi-pelvic prosthesis. Methods: Between February 2017 and January 2020, 11 patients with aseptic loosening or screw fracture of modular hemi-pelvic prosthesis were revised using 3D-printed hemi-pelvic prostheses. There were 7 males and 4 females with an average age of 44 years (range, 25-60 years). In the first operation, all patients underwent total tumor resection, modular hemi-pelvic prosthesis reconstruction, and autologous femoral head transplantation. According to the Enneking pelvic partition system, 8 cases were resected in zones Ⅰ+Ⅱ and 3 cases in zones Ⅰ+Ⅱ+Ⅲ. The interval from the initial operation to this revision ranged from 14.3-66.2 months, with an average of 35.8 months. The operation time, the amount of intraoperative bleeding, and the occurrence of complications were recorded. At 6 months after the first operation, before revision, and at last follow-up, the American Musculoskeletal Tumor Society (MSTS) score and Harris score were used to evaluate the recovery of lower limb function. The pain-free walking distance of patients without brace assistance was recorded at last follow-up. X-ray films were taken at 1 month after the first operation, before revision, and at 1 month after revision, the acetabulum position was assessed by the differences in weight arm and cup height between bilateral hip joints. At last follow-up, the digital X-ray tomography was taken to evaluate the prosthesis-bone integration and the occurrence of aseptic loosening. Results: The operation time was 182.6-238.0 minutes (mean, 197.4 minutes). The amount of intraoperative bleeding was 400-860 mL (mean, 550.0 mL). All incisions healed by first intention with no infection, hip dislocation, nerve damage, or vascular-related adverse events. The MSTS score and Harris score at last follow-up were significantly higher than those at 6 months after the first operation and before revision ( P<0.05), while the score before revision was significantly lower than that at 6 months after the first operation ( P<0.05). At last follow-up, the patients were able to walk more than 1 000 meters painlessly without brace assistance. Imaging review showed that the difference of cup height at 1 month after revision was significantly lower than that at 1 month after the first operation and before revision, and at 1 month after the first operation than before revision operation, and the differences were significant ( P<0.05). There was no significant difference in the difference of weight arm among three time points ( P>0.05). All prostheses were well integrated, and no aseptic loosening of the prosthesis or screw fracture occurred. Conclusion: Revision with 3D-printed hemi-pelvic prostheses benefited in reconstructing stable pelvic ring and natural bodyweight transmission for patients encountering the aseptic loosening or screw fracture of modular hemi-pelvic prosthesis. Early postoperative rehabilitation training can maximize the recovery of patient limb function, reduce pain during walking, and reduce the incidence of complications.


Assuntos
Artroplastia de Quadril , Fraturas Ósseas , Prótese de Quadril , Neoplasias , Masculino , Feminino , Humanos , Adulto , Artroplastia de Quadril/métodos , Resultado do Tratamento , Falha de Prótese , Fraturas Ósseas/cirurgia , Estudos Retrospectivos
7.
World J Gastroenterol ; 29(26): 4214-4221, 2023 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-37475848

RESUMO

BACKGROUND: Deep angiomyxoma (DAM) is a very rare tumor type. Magnetic resonance imaging (MRI) is considered the best imaging modality for diagnosing DAM. Computed tomography (CT) is used mainly to assess the invasion range of DAM. The value of ultrasonography in the diagnosis of DAM is still controversial. Through a literature review, we summarized the current state of ultrasonic examination for DAM and reported for the first time the contrast-enhanced ultrasound (CEUS) features of DAM seen using a biplane transrectal probe. CASE SUMMARY: A 37-year-old woman presented with a sacrococcygeal mass that had gradually increased in size over the previous 6 mo. MRI and CT examinations failed to allow a definite diagnosis to be made. Transperineal core needle biopsy (CNB) guided by transrectal ultrasound and CEUS was suggested after a multidisciplinary discussion. Grayscale ultrasound of the lesion showed a layered appearance with alternating hyperechoic and hypoechoic patterns. Transrectal CEUS showed a laminated distribution of the contrast agent that was consistent with the layered appearance of the tumor on grayscale ultrasound. We performed transperineal CNB of the enhanced area inside the tumor under transrectal CEUS guidance and finally made a definitive diagnosis of DAM through histopathology. The patient underwent laparoscopic-assisted transabdominal surgery combined with transperineal surgery for large pelvic tumor resection and pelvic floor peritoneal reconstruction. No recurrence or metastasis was found at the nine-month follow-up. CONCLUSION: Transrectal CEUS can show the layered perfusion characteristics of the contrast agent, guiding subsequent transperineal CNB of the enhanced area within the DAM.


Assuntos
Mixoma , Neoplasias Pélvicas , Feminino , Humanos , Adulto , Meios de Contraste , Ultrassonografia/métodos , Pelve , Neoplasias Pélvicas/diagnóstico por imagem , Neoplasias Pélvicas/cirurgia , Mixoma/diagnóstico por imagem , Mixoma/cirurgia , Imageamento por Ressonância Magnética/métodos
8.
Curr Oncol ; 30(4): 3859-3870, 2023 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-37185405

RESUMO

Orthopedic oncology has begun to use three-dimensional-printing technology, which is expected to improve the accuracy of osteotomies, ensure a safe margin, and facilitate precise surgery. However, several difficulties should be considered. Cadaver and clinical studies have reported more accurate osteotomies for bone-tumor resection using patient-specific cutting guides, especially in challenging areas such as the sacrum and pelvis, compared to manual osteotomies. Patient-specific cutting guides can help surgeons achieve resection with negative margins and reduce blood loss and operating time. Furthermore, this patient-specific cutting guide could be combined with more precise reconstruction using patient-specific implants or massive bone allografts. This review provides an overview of the basic technologies used in the production of patient-specific cutting guides and discusses their current status, advantages, and limitations. Moreover, we summarize cadaveric and clinical studies on the use of these guides in orthopedic oncology.


Assuntos
Neoplasias Ósseas , Humanos , Neoplasias Ósseas/cirurgia , Pelve , Osteotomia/métodos , Osso e Ossos , Impressão Tridimensional
9.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1009043

RESUMO

OBJECTIVE@#To investigate the effectiveness of three-dimensional (3D)-printed hemi-pelvic prosthesis for revision of aseptic loosening or screw fracture of modular hemi-pelvic prosthesis.@*METHODS@#Between February 2017 and January 2020, 11 patients with aseptic loosening or screw fracture of modular hemi-pelvic prosthesis were revised using 3D-printed hemi-pelvic prostheses. There were 7 males and 4 females with an average age of 44 years (range, 25-60 years). In the first operation, all patients underwent total tumor resection, modular hemi-pelvic prosthesis reconstruction, and autologous femoral head transplantation. According to the Enneking pelvic partition system, 8 cases were resected in zones Ⅰ+Ⅱ and 3 cases in zones Ⅰ+Ⅱ+Ⅲ. The interval from the initial operation to this revision ranged from 14.3-66.2 months, with an average of 35.8 months. The operation time, the amount of intraoperative bleeding, and the occurrence of complications were recorded. At 6 months after the first operation, before revision, and at last follow-up, the American Musculoskeletal Tumor Society (MSTS) score and Harris score were used to evaluate the recovery of lower limb function. The pain-free walking distance of patients without brace assistance was recorded at last follow-up. X-ray films were taken at 1 month after the first operation, before revision, and at 1 month after revision, the acetabulum position was assessed by the differences in weight arm and cup height between bilateral hip joints. At last follow-up, the digital X-ray tomography was taken to evaluate the prosthesis-bone integration and the occurrence of aseptic loosening.@*RESULTS@#The operation time was 182.6-238.0 minutes (mean, 197.4 minutes). The amount of intraoperative bleeding was 400-860 mL (mean, 550.0 mL). All incisions healed by first intention with no infection, hip dislocation, nerve damage, or vascular-related adverse events. The MSTS score and Harris score at last follow-up were significantly higher than those at 6 months after the first operation and before revision ( P<0.05), while the score before revision was significantly lower than that at 6 months after the first operation ( P<0.05). At last follow-up, the patients were able to walk more than 1 000 meters painlessly without brace assistance. Imaging review showed that the difference of cup height at 1 month after revision was significantly lower than that at 1 month after the first operation and before revision, and at 1 month after the first operation than before revision operation, and the differences were significant ( P<0.05). There was no significant difference in the difference of weight arm among three time points ( P>0.05). All prostheses were well integrated, and no aseptic loosening of the prosthesis or screw fracture occurred.@*CONCLUSION@#Revision with 3D-printed hemi-pelvic prostheses benefited in reconstructing stable pelvic ring and natural bodyweight transmission for patients encountering the aseptic loosening or screw fracture of modular hemi-pelvic prosthesis. Early postoperative rehabilitation training can maximize the recovery of patient limb function, reduce pain during walking, and reduce the incidence of complications.


Assuntos
Masculino , Feminino , Humanos , Adulto , Artroplastia de Quadril/métodos , Prótese de Quadril , Resultado do Tratamento , Falha de Prótese , Fraturas Ósseas/cirurgia , Estudos Retrospectivos , Neoplasias
10.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-993130

RESUMO

Objective:To explore the feasibility of a classification prediction model for gamma pass rates (GPRs) under different intensity-modulated radiation therapy techniques for pelvic tumors using a radiomics-based machine learning approach, and compare the classification performance of four integrated tree models.Methods:With a retrospective collection of 409 plans using different IMRT techniques, the three-dimensional dose validation results were adopted based on modality measurements, with a GPR criterion of 3%/2 mm and 10% dose threshold. Then prediction were built models by extracting radiomics features based on dose documentation. Four machine learning algorithms were used, namely random forest (RF), adaptive boosting (AdaBoost), extreme gradient boosting (XGBoost), and light gradient boosting machine (LightGBM). Their classification performance was evaluated by calculating sensitivity, specificity, F1 score, and AUC value. Results:The RF, AdaBoost, XGBoost, and LightGBM models had sensitivities of 0.96, 0.82, 0.93, and 0.89, specificities of 0.38, 0.54, 0.62, and 0.62, F1 scores of 0.86, 0.81, 0.88, and 0.86, and AUC values of 0.81, 0.77, 0.85, and 0.83, respectively. XGBoost model showed the highest sensitivity, specificity, F1 score, and AUC value, outperforming the other three models. Conclusions:To build a GPR classification prediction model using a radiomics-based machine learning approach is feasible for plans using different intensity-modulated radiotherapy techniques for pelvic tumors, providing a basis for future multi-institutional collaborative research on GPR prediction.

11.
Cureus ; 14(11): e31501, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36532919

RESUMO

We encountered a case of life-threatening pulmonary embolism (PE) after an extensive retroperitoneal tumor (RT) surgery. The patient complained of abdominal distension. Preoperatively, an ovarian tumor and colon adenoma were suspected. Upon laparotomy, tumor resection and partial rectal resection were performed; the tumor had originated from the retroperitoneum. On postoperative day 11, the patient suddenly went into fatal shock complicated by strong back pain and dyspnea after the continuous pressure drain was removed. Thrombolysis, anticoagulation, and percutaneous catheter-directed treatment were attempted for the massive PE; however, these induced copious intra-abdominal bleeding. A substantial blood transfusion was required, which increased her body mass by 40 kg. On day 22, an intra-abdominal embolism was resected, and hemodynamics stabilized. RTs have a potential risk of perioperative thromboembolism; therefore, we suggest that surgery should take place in an academic hospital with an experienced circulatory team. To preserve life after PE, early diagnosis and multidisciplinary treatment are indispensable.

12.
Front Cardiovasc Med ; 9: 1011311, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36330006

RESUMO

Purpose: Uterine fibroids are associated with hypertension in non-pregnant women. We aimed to evaluate the association between uterine fibroids and pre-eclampsia (PE). Patients and methods: Participants were pregnant women who delivered in the Department of Obstetrics of the People's Hospital of Xinjiang Uygur Autonomous Region between January and December 2021. Patients with PE were identified as the case group, whereas those without PE were selected as the control group, using age-matching and a ratio of 1:5. Ultrasound examination during early pregnancy was used to detect uterine fibroids. Multivariable logistic regression was applied to evaluate the association between uterine fibroids and PE. Results: In total, 121 cases with PE and 578 controls without PE were included, with mean age of 32.9 years and gestational age of 37.7 weeks. Time of ultrasound examination was 12.0 ± 2.6 weeks. The case group had a significantly higher exposure rate of uterine fibroids than the control group (14.0 vs. 6.9%, P = 0.009). Multivariable Logistic regression models adjusted for potential confounding factors, including gestational age and blood pressure in early gestation, showed that pregnant women with uterine fibroids in early pregnancy exhibited three-fold higher odds for PE (OR, 3.02; 95% CI, 1.20-7.60; P = 0.019). Sensitivity analysis, which excluded those with gestational diabetes, further confirmed the robustness of the results. The association between uterine fibroids and PE was stronger in pregnant women aged ≥35 years and multiparas. Conclusion: Uterine fibroids are significantly associated with an increased risk of PE in pregnant women. Uterine fibroids may serve as a new factor for identifying pregnant women at high risk of PE, and the effect of myomectomy before pregnancy on prevention of PE is worth further exploring.

13.
Urologiia ; (5): 84-89, 2022 Nov.
Artigo em Russo | MEDLINE | ID: mdl-36382823

RESUMO

INTRODUCTION: Retrograde intrarenal surgery (RIRS) is being actively implemented in the treatment of renal stones and other diseases. If necessary, RIRS can be combined with percutaneous procedures. AIM: To study the results of RIRS in patients with nephrolithiasis and various renal disorders. MATERIALS AND METHODS: A total of 106 patients who undergone RIRS were included in the study. There were 66 men (63.4%) and 40 women (36.6%). Mean age was 46.8+/-15.6 years. The indication for RIRS in 84 (79.2%) patients was renal stones. Calculus in calyceal diverticulum were diagnosed in 6 (5.7%), encrusted stents in 8 (7.7%), urinary fistulas after partial nephrectomy in 5 (4.7%), pelvis tumors in 2 (1.9%), pelvis perforation after marsupialization of parapelvic cyst in 1 (0.9%) patient, respectively. Simultaneous retro- and antegrade procedures were performed in 27 (25.5%) cases. In those with nephrolithiasis and encrusted stents, lithotripsy was done with the removal of stone fragments. Two patients underwent endoscopic resection of the pelvis tumor. In six patients, the neck of the diverticulum was incised after lithotripsy, while in five cases retrograde endoscopically controlled percutaneous treatment urinary fistulae was performed. In one case, laser fulguration of the pelvis defect with stenting was done. RESULTS: RIRS was effective in 72 (85.7%) of 84 patients with renal stones. The operation time was 70.8+/-10.2 minutes. In 12 (14.3%) cases with residual fragments, extracorporeal shock-wave lithotripsy (n=7) and repeated RIRS (n=5) were performed. The efficiency of RIRS after two sessions was 91.7%. Complications were observed in 11 (10.4%) patients. With encrusted stents, the operation time was 95.0+/-16.5 min. After laser fragmentation of encrustations in the lower part of the stent, percutaneous lithotripsy was performed with antegrade removal of its upper half. The time for RIRS in those with diverticula was 60.0+/-8.5 min, the average stone size was 8 mm (from 6 to 10 mm). In all cases lithotripsy with mucosal fulguration was successfully done. The procedures for urinary fistulae were also effective (operation time was 45.0 +/- 20.5 minutes) and there were no complications. CONCLUSION: RIRS is a safe and effective treatment for patients with nephrolithiasis and other kidney disorders. Modern flexible ureteroscopes allows to examine the collecting system and to perform lithotripsy and removal of stone fragments.


Assuntos
Cistos , Divertículo , Cálculos Renais , Litotripsia , Nefrolitotomia Percutânea , Fístula Urinária , Masculino , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Litotripsia/métodos , Cálculos Renais/terapia , Nefrolitotomia Percutânea/métodos , Resultado do Tratamento , Divertículo/etiologia
14.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 66(5): 403-409, Sep-Oct 2022. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-210645

RESUMO

Introducción: Los tumores del anillo pélvico suponen un reto por la dificultad de obtener márgenes quirúrgicos adecuados. Herramientas como la navegación quirúrgica o la impresión 3D para la fabricación de plantillas de posicionamiento quirúrgico paciente-específicas ayudan en la planificación preoperatoria y la ejecución intraoperatoria. Su correcta colocación es fundamental en localizaciones complejas como la pelvis, por lo que es necesario identificar los errores de posicionamiento. El objetivo de este estudio es demostrar la fiabilidad en la colocación de plantillas 3D para la realización de osteotomías en el anillo pélvico. Material y métodos: Estudio experimental en cadáver con 10 hemipelvis. Se realiza TC para la obtención del modelo tridimensional, planificación de osteotomías, diseño de plantillas de posicionamiento en rama isquiopubiana (I), iliopubiana (P), supracetabular (S) y cresta iliaca (C); y un marcador de posicionamiento (rigid-body) sobre las plantillas C y S para la navegación. Las plantillas y el rigid-body son impresos en 3D y se colocan según planificación previa. La navegación permite comprobar la posición final de las plantillas y de las osteotomías. Resultados: El posicionamiento de las plantillas respecto a la planificación preoperatoria varió dependiendo de la localización, siendo mayor el error en las de cresta iliaca. Utilizando la navegación, la media de error de distancia al plano de corte está en 3,5mm, excepto en pubis (5-8mm), estando condicionado por la posición del rigid body. Conclusión: El uso de plantillas paciente-específicas impresas en 3D es una herramienta fiable para la realización de osteotomías en cirugía oncológica pélvica.(AU)


Introduction: Pelvic ring tumors pose a challenge due to the difficulty in obtaining adequate surgical margins. Tools such as surgical navigation or 3D printing for the fabrication of patient-specific surgical positioning templates help in preoperative planning and intraoperative execution. Their correct positioning is essential in complex locations such as the pelvis, so it is necessary to identify positioning errors. The aim of this study is to demonstrate the reliability of 3D template placement for pelvic ring osteotomies. Material and methods: Experimental study in cadaver with 10 hemipelvis. CT was performed to obtain the three-dimensional model, planning of osteotomies, design of positioning templates in ischiopubic (I), iliopubic (P), supracetabular (S) and iliac crest (C) branches; and a positioning marker (rigid-body) on the C and S templates for navigation. The templates and rigid-body are 3D printed and positioned according to pre-planning. Navigation allows the final position of the inserts and osteotomies to be checked. Results: The positioning of the templates with respect to the preoperative planning varied depending on the location, being greater the error in those of the iliac crest. Using navigation the mean error of distance to the cutting plane is 3.5mm, except in pubis 5-8mm), being conditioned by the position of the rigid body. Conclusion: The use of patient-specific templates printed in 3D is a reliable tool for performing osteotomies in pelvic cancer surgery.(AU)


Assuntos
Humanos , Pelve/cirurgia , Ortopedia/métodos , Oncologia , Imageamento Tridimensional , Impressão Tridimensional , Cadáver , Osteotomia , Neoplasias Pélvicas , Neoplasias , 28573 , Ferimentos e Lesões , Traumatologia
15.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 66(5): T403-T409, Sep-Oct 2022. ilus, tab, graf
Artigo em Inglês | IBECS | ID: ibc-210648

RESUMO

Introducción: Los tumores del anillo pélvico suponen un reto por la dificultad de obtener márgenes quirúrgicos adecuados. Herramientas como la navegación quirúrgica o la impresión 3D para la fabricación de plantillas de posicionamiento quirúrgico paciente-específicas ayudan en la planificación preoperatoria y la ejecución intraoperatoria. Su correcta colocación es fundamental en localizaciones complejas como la pelvis, por lo que es necesario identificar los errores de posicionamiento. El objetivo de este estudio es demostrar la fiabilidad en la colocación de plantillas 3D para la realización de osteotomías en el anillo pélvico. Material y métodos: Estudio experimental en cadáver con 10 hemipelvis. Se realiza TC para la obtención del modelo tridimensional, planificación de osteotomías, diseño de plantillas de posicionamiento en rama isquiopubiana (I), iliopubiana (P), supracetabular (S) y cresta iliaca (C); y un marcador de posicionamiento (rigid-body) sobre las plantillas C y S para la navegación. Las plantillas y el rigid-body son impresos en 3D y se colocan según planificación previa. La navegación permite comprobar la posición final de las plantillas y de las osteotomías. Resultados: El posicionamiento de las plantillas respecto a la planificación preoperatoria varió dependiendo de la localización, siendo mayor el error en las de cresta iliaca. Utilizando la navegación, la media de error de distancia al plano de corte está en 3,5mm, excepto en pubis (5-8mm), estando condicionado por la posición del rigid body. Conclusión: El uso de plantillas paciente-específicas impresas en 3D es una herramienta fiable para la realización de osteotomías en cirugía oncológica pélvica.(AU)


Introduction: Pelvic ring tumors pose a challenge due to the difficulty in obtaining adequate surgical margins. Tools such as surgical navigation or 3D printing for the fabrication of patient-specific surgical positioning templates help in preoperative planning and intraoperative execution. Their correct positioning is essential in complex locations such as the pelvis, so it is necessary to identify positioning errors. The aim of this study is to demonstrate the reliability of 3D template placement for pelvic ring osteotomies. Material and methods: Experimental study in cadaver with 10 hemipelvis. CT was performed to obtain the three-dimensional model, planning of osteotomies, design of positioning templates in ischiopubic (I), iliopubic (P), supracetabular (S) and iliac crest (C) branches; and a positioning marker (rigid-body) on the C and S templates for navigation. The templates and rigid-body are 3D printed and positioned according to pre-planning. Navigation allows the final position of the inserts and osteotomies to be checked. Results: The positioning of the templates with respect to the preoperative planning varied depending on the location, being greater the error in those of the iliac crest. Using navigation the mean error of distance to the cutting plane is 3.5mm, except in pubis 5-8mm), being conditioned by the position of the rigid body. Conclusion: The use of patient-specific templates printed in 3D is a reliable tool for performing osteotomies in pelvic cancer surgery.(AU)


Assuntos
Humanos , Pelve/cirurgia , Ortopedia/métodos , Oncologia , Imageamento Tridimensional , Impressão Tridimensional , Cadáver , Osteotomia , Neoplasias Pélvicas , Neoplasias , 28573 , Ferimentos e Lesões , Traumatologia
16.
Front Oncol ; 12: 935059, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35847863

RESUMO

Background: Reconstruction of pelvis girdle stability after tumor-induced hemipelvectomy remains challenging. We surgically treated 13 patients with custom-made, three-dimensional printed hemipelvic prostheses. We aim to identify the preliminary outcomes for patients who have been managed with more mixed regions of prosthetic pelvic reconstruction and the feasibility of two reconstructive systems. Methods: Seven male patients and 6 female patients treated at our center between January 2019 and May 2021 were included. There were 11 primary sarcomas and 2 solitary bone metastases. After en bloc tumor resection, two types of personalized, three-dimensional printed prostheses were fixed to restore the stability and rebuild the load transfer. The position of the reconstructed hemipelvis was evaluated on an anteroposterior plain radiograph. The complications and outcomes were traced. One amputation specimen was discovered through histological analysis of the porous structure. Results: The operative duration was 467 ± 144 min, and the blood loss was 3,119 ± 662 ml. During a follow-up of 22.4 ± 8.5 months, two patients had delayed wound healing and one had a second-stage flap transfer. One patient with osteosarcoma died of pulmonary metastasis 27 months after surgery. Two patients with marginal resection suffered from local recurrence and had extra surgeries. One patient had traumatic hip dislocation 2 months after surgery and manipulative reduction was performed. The acetabular inclination of the affected side was 42.2 ± 4.3°, compared with 42.1 ± 3.9° on the contralateral side. The horizontal distance between the center of the femoral head and the middle vertical line was 10.4 ± 0.6 cm, while the reconstructed side was 9.8 ± 0.8 cm. No significant difference in acetabular position after surgery was found (p > 0.05). The amputation specimen harvested from one patient with local recurrence demonstrated bone and soft tissue ingrowth within the three-dimensional printed trabecular structure. Walking ability was preserved in all patients who are still alive and no prosthesis-related complications occurred. The MSTS score was 22.0 ± 3.7. Conclusions: Both types of custom-made, three-dimensional printed prostheses manifested excellent precision, mechanical stability, and promising functional rehabilitation. The porous structure exhibited favorable histocompatibility to facilitate the ingrowth of bone and soft tissue.

17.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 36(7): 796-803, 2022 Jul 15.
Artigo em Chinês | MEDLINE | ID: mdl-35848173

RESUMO

Objective: To explore the surgical skills of modified Gibson combined with modified ilioinguinal (MGMII) approach in the treatment of Enneking Ⅱ+Ⅲ pelvic malignant tumors in the three-dimensional (3D) printed customized integrated hemipelvic prosthesis, and to evaluate the convenience and accuracy of the surgical approach and the short-term effectiveness. Methods: Between January 2017 and March 2019, 7 patients with Enneking Ⅱ+Ⅲ pelvic malignant tumors were treated with tumor resection and 3D printed hemipelvic prosthesis replacement via MGMII approach. There were 6 males and 1 female. The age ranged from 23 to 68 years, with an average of 43.7 years. There was 1 chondrosarcoma, 1 Ewing's sarcoma, 1 osteosarcoma, 1 malignant Schwannoma, 2 metastatic renal clear cell carcinoma, and 1 metastatic hepatocellular carcinoma. The Enneking stage of 4 cases of primary malignant tumor was stage ⅡB. The disease duration was 6-12 months, with an average of 9.5 months. The preoperative Harris hip score (HHS) was 82.1±1.4 and the Musculoskeletal Tumor Society (MSTS) score was 21.4±1.1. The tumor size by imaging examination was 5.1-9.1 cm, with an average of 6.9 cm. The operation time, intraoperative blood loss, postoperative blood transfusion volume, and postoperative complications were recorded. Postoperative pathological examination confirmed tumor residue according to R classification criteria. The lower limb length, acetabular height, acetabular eccentricity, abduction angle, and anteversion angle were measured and the bone integration was observed by imaging review. Bilateral abductor muscle strengths were measured, and joint function was evaluated by MSTS score and HHS score. Results: All operations were successfully completed. The operation time was 210-360 minutes (mean, 280.0 minutes); the intraoperative blood loss was 1 300-2 500 mL (mean, 1 785.7 mL); the postoperative blood transfusion volume was 0-11 U (mean, 6.1 U). Postoperative pathological examination confirmed R0 resection assisted by osteotomy guide plate. All incisions healed by first intention. All patients were followed up 30-48 months (mean, 41.3 months). At last follow-up, the imaging review showed the good osseointegration in all 7 cases. There was no significant difference in the lower limb length, acetabular height, acetabular eccentricity, abduction angle, and anteversion angle between the affected side and the healthy side ( P>0.05), all of which met the requirements of anatomical reconstruction. At 3 months after operation, the ratios of muscle strength between the affected side and the healthy side was 68.29%±7.41% at 3 months and 89.86%±2.79% at 12 months, showing a significant difference between the two time points ( t=8.242, P=0.000). At last follow-up, the MSTS score and HHS score were 27.3±0.8 and 96.6±1.4, respectively, which significantly improved when compared with those before operation ( P<0.05). None of the patients had assisted walking at last follow-up. There was no recurrence, death, or complications such as deep infection, dislocation of the prosthesis, or fracture of the prosthesis or screw. Conclusion: MGMII approach can expose the posterior column of the acetabulum, especially the ischial tubercle, which is helpful to avoid tumor rupture during tumor resection and preserve the muscle functions such as gluteus medius and iliac muscle while ensuring the resection scope.


Assuntos
Artroplastia de Quadril , Membros Artificiais , Neoplasias Ósseas , Acetábulo/cirurgia , Adulto , Idoso , Artroplastia de Quadril/métodos , Neoplasias Ósseas/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
18.
Iowa Orthop J ; 42(1): 263-265, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35821952

RESUMO

Pigmented villonodular synovitis (PVNS) and synovial chondromatosis (SC) of the hip are rare synovial diseases that can induce joint destruction without early diagnosis and treatment. The extent of surgical excision is critical given the high rates of recurrence. In the presented case, a 19-year-old female was referred to our institution with progressive left hip pain and radiologic evidence of an intra-articular mass that was consistent with PVNS versus SC. Her medical history was notable for a prior excision of a fibrous lesion at an outside hospital at age 13 with persistent pain. The patient underwent a surgical hip dislocation approach to obtain near-complete visualization of the femoroacetabular joint, ensuring complete evaluation and excision. The tumor was intraoperatively diagnosed as SC and excised accordingly, during an uneventful operation. Pathology confirmed the diagnosis. The essential diagnostic and surgical steps for the management of this pelvic tumor diagnostic dilemma are described. Level of Evidence: V.


Assuntos
Condromatose Sinovial , Luxação do Quadril , Sinovite Pigmentada Vilonodular , Adolescente , Adulto , Condromatose Sinovial/diagnóstico por imagem , Condromatose Sinovial/cirurgia , Feminino , Luxação do Quadril/diagnóstico por imagem , Luxação do Quadril/cirurgia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos , Dor , Sinovite Pigmentada Vilonodular/diagnóstico por imagem , Sinovite Pigmentada Vilonodular/cirurgia , Adulto Jovem
19.
World J Surg Oncol ; 20(1): 185, 2022 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-35676716

RESUMO

BACKGROUND: Paraganglioma of the urinary bladder (Pub) is rare and presents with clinical symptoms caused by catecholamine production and release. The typical symptoms of Pub are hypertension, macroscopic hematuria, and a hypertensive crisis during micturition. The average size of detected Pubs is approximately 3 cm. Herein, we report a case of a large Pub in which the symptoms were masked by oral medication, precise preoperative diagnosis was difficult, and intraoperative confirmation of tumoral adhesion to the rectum resulted in hypertensive attacks during surgery. CASE PRESENTATION: A 64-year-old Japanese male with a history of hypertension and arrhythmia controlled with oral medication presented with a large tumor in the pelvic region, detected on examination for weight loss, with no clinical symptoms. Computed tomography and magnetic resonance imaging revealed a tumor measuring 77 mm in diameter in the posterior wall of the urinary bladder. The border with the rectum was unclear, and the tumor showed heterogeneous enhancement in the solid part with an enhancing hypodense lesion. Cystoscopy revealed compression of the bladder trigone by external masses; however, no tumor was visible in the lumen. Endoscopic ultrasonography-guided fine-needle aspiration revealed CD34-positive spindle-shaped cells in the fibrous tissue, suggestive of a mesenchymal neoplasm. The tumor was suspected to be a gastrointestinal stromal tumor, and surgery was performed. After laparotomy, we suspected that the tumor had invaded the rectum, and total cystectomy and anterior resection of the rectum were performed. Histologically, the tumor cells had granular or clear amphophilic cytoplasm with an oval nucleus and nests of cells delimited by connective tissue and vascular septations. Immunohistochemically, the tumor was positive for chromogranin A, CD56, and synaptophysin, and a diagnosis of paraganglioma of the urinary bladder was confirmed. There was no tumor recurrence at the 7-month follow-up. CONCLUSION: This case highlights the importance of careful examination of pelvic tumors, including endocrine testing, for detecting paraganglioma of the urinary bladder in patients with a history of hypertension or arrhythmia.


Assuntos
Neoplasias das Glândulas Suprarrenais , Tumores do Estroma Gastrointestinal , Hipertensão , Paraganglioma , Feocromocitoma , Neoplasias da Bexiga Urinária , Tumores do Estroma Gastrointestinal/diagnóstico , Tumores do Estroma Gastrointestinal/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Paraganglioma/diagnóstico , Paraganglioma/patologia , Paraganglioma/cirurgia , Pelve/patologia , Reto/patologia , Bexiga Urinária/patologia , Neoplasias da Bexiga Urinária/diagnóstico , Neoplasias da Bexiga Urinária/patologia , Neoplasias da Bexiga Urinária/cirurgia
20.
Rare Tumors ; 14: 20363613221103751, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35651782

RESUMO

Pleomorphic hyalinizing angiectatic tumor (PHAT) is a rare tumor of the soft tissue, usually located in lower extremities. There are rarely tumors reported in other anatomic locations. Herein, we report retroperitoneal PHAT in a male patient. A 41-year-old man was referred to our clinic due to an incidentally found retroperitoneal mass. Computed tomography (CT) scan showed a solid hypoechoic lesion containing fat component and calcified elements measuring about 80*72*45 mm in the right lower quadrant (RLQ) of the abdomen. Magnetic resonance imaging (MRI) showed circumscribe lesion measuring about 60 x 48 mm with partial enhancement and fat component. In pelvic exploration, a large mass was found that had encased the right external iliac artery and vein. Therefore, the mass and its surrounding iliac vessels were excised and removed en block. Then, the external iliac vessels were reconstructed with Gortex graft. No recurrence was found in 1 month and 3 months post-operation follow up. We report a pelvic retroperitoneal PHAT as a rare location of this tumor. It seems that PHAT must be considered in differential diagnosis in patients with soft tissue tumors in the pelvic cavity.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...