Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Injury ; 55(8): 111700, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38941910

RESUMO

BACKGROUND AND PURPOSE: Pediatric pelvic fractures are uncommon, representing 0.2-3% of total pediatric fractures. The long-term patient-reported outcome in the pediatric population has not been evaluated yet. The purpose of the study was to describe the epidemiology of pelvic and acetabular fractures in pediatric patients including long-term patient-reported outcomes. PATIENTS AND METHODS: The Swedish Fracture Register (SFR) was used to identify all patients aged 6-17 years at injury with a pelvic fracture between 2015 and 2021. All patients were invited to answer Patient-Reported measurement instruments in 2021. RESULTS: The study cohort consisted of 223 patients with a median age at fracture of 15 years and with 62 % boys. 201 sustained a pelvic and 22 acetabular fractures. Falls were the leading cause of fracture, followed by transport accidents. Most fractures (both pelvis and acetabulum) were type A (73 %), and 21 fractures (9 %) could not be classified according to AO. 85 % of fractures were treated non-surgically. All Type C fractures were treated surgically. Seven PROMIS® profile domains were completed by 31 % of the sample at a mean follow-up time of 3.5 years after pelvic/acetabular fracture. Most patients had "no concern" or "mild concern" but those who had surgery had an inferior t-score in most domains. CONCLUSION: Most fractures occurred in older individuals, with falls during sports activities being the most common cause. This raises important questions about prevention strategies. The PROMIS-Pain-Interference scale indicated that the younger the age at fracture, the more pain was reported at follow-up.

2.
Eur J Orthop Surg Traumatol ; 33(8): 3443-3448, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37184595

RESUMO

PURPOSE: To compare outcomes of fluoroscopic-assisted supra-acetabular pin placement percutaneous technique versus the open technique in traumatic pelvic fractures. METHODS: Prospective randomized controlled trial was performed at Maharat Nakhon ratchasima hospital from January 2020 to March 2021. Time, size of wound, and position of supra-acetabular pin were recorded intraoperatively. Pin positions were confirmed and measured by postoperative CT scan. Complications such as cortex penetration, infection, hip joint violation, and lateral thigh numbness were recorded at 2 weeks postoperatively. RESULTS: Twenty patients (40 hemipelvis) were randomized to fluoroscopic-assisted and non-fluoroscopic groups. Time taken for supra-acetabular pin placement for fluoroscopic-assisted and non-fluoroscopic-assisted groups was 211 and 522 s, respectively (P value < 0.001). Average wound size was 2.81 cm in the fluoroscopic-assisted group and 6.01 cm in the non-fluoroscopic-assisted group (P value < 0.001). Overall complications were similar in both groups with higher infection rates in the fluoroscopic-assisted group (5 and 0%, respectively). DISCUSSION: Pelvic fracture is a life-threatening condition, which requires emergency pelvic stabilization. This study examined operative times for supra-acetabular placement and complication rates. The results show shorter operative times for the non-fluoroscopic-assisted technique without significant differences in complication rates. CONCLUSION: Non-fluoroscopic technique greatly reduced operative times for supra-acetabular pin placement with comparable safety to the fluoroscopic-assisted technique.


Assuntos
Fraturas Ósseas , Ossos Pélvicos , Humanos , Estudos Prospectivos , Tailândia , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Fraturas Ósseas/cirurgia , Fluoroscopia/métodos , Ossos Pélvicos/diagnóstico por imagem , Ossos Pélvicos/cirurgia
3.
J Craniovertebr Junction Spine ; 14(1): 55-58, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37213568

RESUMO

Introduction: Spinopelvic dissociation was described first in 1969. It is an injury characterized by the separation of the lumbar spine, with parts of the sacrum, from the rest of the sacrum and pelvis with the appendicular skeleton through the sacral ala. Spinopelvic dissociation has an incidence of approximately 2.9% of all pelvic disruptions and corresponds with high-energy trauma. The objective of this study was to review and analyze a case series of spinopelvic dissociations that were treated in our institution from May 2016 to December 2020. Methods: This was a retrospective study reviewing medical records of a series of cases with spinopelvic dissociating. A total of nine patients were encountered. Demographic data including gender and age were analyzed with the mechanism of injury, fracture characteristics, and classifications in addition to neurological deficits. Fractures were classified by the AO Spine Sacral Classification System. Moreover, neurological deficits were classified using the Gibbon's classification score. Finally, the Majeed score was utilized for the assessment of the functional outcome after the injury. Results: A total of nine patients with spinopelvic dissociation were encountered, seven males and two females. Seven patients were due to motor vehicle accidents, one patient was due to a suicidal attempt, and one patient was due to seizure. Four patients suffered from neurological deficits. One patient needed an intensive care unit admission. Spinopelvic fixation was done for all patients. One patient had surgical wound infection with wound dehiscence, one had infected instruments with confirmed spine osteomyelitis, and one had a focal neurological deficit. Six patients went on to heal and showed complete neurological improvements. Conclusion: Spinopelvic dissociation injuries represent a variety of injuries that are commonly associated with high-energy trauma. The triangular fixation method has proven to be a stable construct in dealing with such injuries.

4.
Arch Orthop Trauma Surg ; 143(10): 6049-6056, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37103608

RESUMO

INTRODUCTION: The purpose of this study is to (1) describe a pre-operative planning technique using non-reformatted CT images for insertion of multiple transiliac-transsacral (TI-TS) screws at a single sacral level, (2) define the parameters of a sacral osseous fixation pathway (OFP) that will allow for insertion of two TI-TS screws at a single level, and (3) identify the incidence of sacral OFPs large enough for dual-screw insertion in a representative patient population. METHODS: Retrospective review at a level-1 academic trauma center of a cohort of patients with unstable pelvic injuries treated with two TI-TS screws in the same sacral OFP, and a control cohort of patients without pelvic injuries who had CT scans for other reasons. RESULTS: Thirty-nine patients had two TI-TS screws at S1. Eleven patients, all with dysmorphic osteology, had two TI-TS screws at S2. The average pathway size in the sagittal plane at the level the screws were placed was 17.2 mm in S1 vs 14.4 mm in S2 (p = 0.02). Twenty-one patients (42%) had screws that were intraosseous and 29 (58%) had part of a screw that was juxtaforaminal. No screws were extraosseous. The average OFP size of intraosseous screws was 18.1 mm vs. 15.5 mm for juxtaforaminal screws (p = 0.02). Fourteen millimeters was used as a guide for the lower limit of the OFP for safe dual-screw fixation. Overall, 30% of S1 or S2 pathways were ≥ 14 mm in the control group, with 58% of control patients having at least one of the S1 or S2 pathways ≥ 14 mm. CONCLUSIONS: OFPs ≥ 7.5 mm in the axial plane and 14 mm in the sagittal plane on non-reformatted CT images are large enough for dual-screw fixation at a single sacral level. Overall, 30% of S1 and S2 pathways were ≥ 14 mm and 58% of control patients had an available OFP in at least one sacral level.


Assuntos
Fraturas Ósseas , Ossos Pélvicos , Humanos , Fixação Interna de Fraturas/métodos , Parafusos Ósseos , Sacro/diagnóstico por imagem , Sacro/cirurgia , Sacro/lesões , Tomografia Computadorizada por Raios X , Estudos Retrospectivos , Ílio/cirurgia , Ílio/lesões , Ossos Pélvicos/lesões , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia
5.
J Biomech ; 150: 111490, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36878113

RESUMO

Pelvis and lumbar spine fractures occur in falls, motor vehicle crashes, and military combat events. They are attributed to vertical impact from the pelvis to the spine. Although whole-body cadavers were exposed to this vector and injuries were reported, spinal loads were not determined. While previous studies determined injury metrics such as peak forces using isolated pelvis or spine models, they were not conducted using the combined pelvis-spine columns, thereby not accounting for the interaction between the two body regions. Earlier studies did not develop response corridors. The study objectives were to develop temporal corridors of loads at the pelvis and spine and assess clinical fracture patterns using a human cadaver model. Vertical impact loads were delivered at the pelvic end to twelve unembalmed intact pelvis-spine complexes, and pelvis forces and spinal loads (axial, shear and resultant and bending moments) were obtained. Injuries were classified using clinical assessments from post-test computed tomography scans. Spinal injuries were stable in eight and unstable in four specimens. Pelvis injuries included ring fractures in six and unilateral pelvis in three, sacrum fractures in ten, and two specimens did not sustain any injuries to the pelvis or sacrum complex. Data were grouped based on time to peak velocity, and ± one standard deviation corridors about the mean of the biomechanical metrics were developed. Time-history corridors of loads at the pelvis and spine, hitherto not reported in any study, are valuable to assess the biofidelity of anthropomorphic test devices and assist validating finite element models.


Assuntos
Traumatismos por Explosões , Fraturas da Coluna Vertebral , Traumatismos da Coluna Vertebral , Humanos , Vértebras Lombares , Explosões , Pelve , Cadáver , Fenômenos Biomecânicos/fisiologia
6.
Injury ; 53(6): 2110-2113, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35305806

RESUMO

STUDY DESIGN: Retrospective Cohort Study OBJECTIVES: The AOSpine Sacral Classification System was proposed as a comprehensive and universally accepted new classification for Sacral Fractures, and was recently internally validated. However, an external, independent and multidisciplinary reports on validation of this classification is lacking. Aim of the present study is to analyze the interobserver reliability and intraobserver reproducibility of the AOSpine Sacral Classification System for Sacral Fractures between orthopedic spinal and pelvic surgeons with different levels of experience. METHODS: Our institutional database was searched to retrieve patients with acute, traumatic sacral injury admitted from June 2017 to June 2020. For each patients, X-Rays and CT scans were collected. Three Orthopedic Pelvic Surgeons (Group A) and three Spine Surgeons (Group B), with different level of experience (Junior, 〈 5 years; Middle, 5-10 years; Expert 〉 10 years) independently classified all the sacral fractures included in the dataset, with two separate evaluation three weeks apart. Both intra and interobserver reliability were calculated with k-coefficient. RESULTS: Overall, 150 patients were included in the final dataset, for a total of 1800 different assessments, with all the subtypes reported. The intraobserver reproducibility for the whole group was substantial (κ=0.72). Overall, the interobserver reliability was moderate, with a κ=0.57. When only fracture type was taken in account, the κ value became substantial (κ=0.62). No significant differences were found comparing group A and group B (0.55 vs κ 0.55, p>0.05). No significant differences according to surgeon's experience were found; however, the κ value was slightly lower among the junior surgeons. CONCLUSIONS: Our findings confirmed the reliability and reproducibility of this classification in clinical practice. In the current study the surgeon's expertise (pelvic and spinal trauma) and the level of experience does not influence the reliability of the classification system.


Assuntos
Lesões do Pescoço , Fraturas da Coluna Vertebral , Cirurgiões , Humanos , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia
7.
Unfallchirurg ; 124(8): 680-684, 2021 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-34236449

RESUMO

OBJECTIVE OF SURGERY: High primary stability of the pelvic girdle with full weight bearing. INDICATIONS: Instability and immobility in patients with osteoporotic fractures of the pelvis. CONTRAINDICATIONS: Decubitus ulcers, infections. SURGICAL TECHNIQUE: Minimally invasive posterior locked compression plate 4.5 LCP (locked compression plate, DePuy Synthes, Zuchwil, Switzerland). FOLLOW-UP: Immediate mobilization with full weight bearing, X­ ray control. EVIDENCE: The follow-up examination of a collective of 34 patients showed no implant loosening and a relatively low radiation exposure.


Assuntos
Fraturas de Estresse , Fraturas por Osteoporose , Placas Ósseas , Fixação Interna de Fraturas , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/cirurgia , Pelve
8.
Int Orthop ; 45(12): 3179-3184, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34100986

RESUMO

PURPOSE: Stability of the dorsal pelvic ring is important for patient mobilisation and can be restored using several surgical procedures after fracture. Placement of percutaneous iliosacral screws is a reliable and minimal-invasive technique to achieve stabilisation of the dorsal pelvic ring by placement of two screws in the first sacral vertebra. Aim of this study was to evaluate 3D CT scans regarding the anatomical possibility to place two 7.3 mm iliosacral screws for fixation of the dorsal pelvic ring. METHODS: 3D CT datasets of 500 consecutive trauma patients with 1000 hemipelves of a mid-european level I trauma centre with or without pelvic injury were evaluated and measured bilaterally in this retrospective study. RESULTS: One thousand hemipelvic datasets of 500 patients (157 females, 343 males) with a mean age of 49.7 years (18 to 95) were included in this study. Only 16 hemipelves (1.6%, 11 in females, 5 in males) in 14 patients (2.8%, 9 females = 5.73%, 5 males = 1.5%) showed too narrow corridors so that 7.3 mm screw placement would not be possible (p = 0.001). In women, too narrow corridors occurred 3.9 times as often as in men. Only two females showed this bilaterally. CONCLUSION: The evaluation of 3D CT scans of the pelvis showed the importance of planning iliosacral screw placement, especially if two 7.3 mm screws are intended to be placed in the first sacral vertebra.


Assuntos
Fraturas Ósseas , Ossos Pélvicos , Parafusos Ósseos , Feminino , Fixação Interna de Fraturas , Humanos , Ílio/diagnóstico por imagem , Ílio/cirurgia , Masculino , Pessoa de Meia-Idade , Ossos Pélvicos/diagnóstico por imagem , Ossos Pélvicos/cirurgia , Pelve , Estudos Retrospectivos , Sacro/diagnóstico por imagem , Sacro/cirurgia , Tomografia Computadorizada por Raios X
9.
Eur J Orthop Surg Traumatol ; 29(5): 1141-1145, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30848379

RESUMO

Operative fixation of acetabular fractures involving the quadrilateral surface presents a challenging clinical scenario. Classically, quadrilateral plate buttress was achieved via the use of a "seven" plate. More recently, the use of an anatomic, pre-contoured design has been gaining popularity due to its pre-contoured shape and larger footprint, allowing for a wider quadrilateral plate buttress. The current study presents using a stainless steel locking calcaneal plate to obtain similar surface area coverage as the modern pre-contoured quadrilateral plate, but at a lower cost.Level of evidence IV.


Assuntos
Acetábulo , Placas Ósseas , Fixação Interna de Fraturas , Fraturas Ósseas , Complicações Pós-Operatórias/prevenção & controle , Acetábulo/diagnóstico por imagem , Acetábulo/lesões , Acetábulo/cirurgia , Adulto , Fenômenos Biomecânicos , Parafusos Ósseos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/reabilitação , Consolidação da Fratura , Fraturas Ósseas/diagnóstico , Fraturas Ósseas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Aço Inoxidável/farmacologia , Resultado do Tratamento
10.
Injury ; 46 Suppl 4: S71-4, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26542869

RESUMO

BACKGROUND: Acetabular fracture surgery is demanding and screw placement along narrow bony corridors remains challenging. It necessitates x-ray radiation for fluoroscopically assisted screw insertion. The purpose of this cadaver study was to evaluate the feasibility, accuracy and operation time of a novel electromagnetic navigation system for screw insertion along predefined acetabular corridors. METHODS: A controlled laboratory study with a total of 24 electromagnetically navigated screw insertions was performed on 8 cadaveric acetabula. 3 peri-acetabular bony corridors (QSS, Quadrilateral Surface Screw; IAS, Infra-Acetabular Screw; PCS, Posterior Column Screw) were defined and screws were placed in a defined order without fluoroscopy. Operation time was documented. Postoperative CT scans were performed to analyse accuracy of screw placement. RESULTS: Mean cadaver age was 70.4 ± 11.7. Successful screw placement was accomplished in 22 out of 24 (91.7%) cases. The overall mean time for all 3 acetabular screws was 576.6 ± 75.9s. All 3 complications occurred during the placement of the IAS due to an impassable narrow bony corridor. QSS mean length was 50 ± 5mm, IAS mean length was 85 ± 10mm and PCS mean length was 120 ± 5mm. CONCLUSION: In this cadaver study the novel electromagnetic navigation system was feasible to allow accurate screw placement without fluoroscopy in defined narrow peri-acetabular bony corridors.


Assuntos
Acetábulo/diagnóstico por imagem , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/diagnóstico por imagem , Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios X , Acetábulo/anatomia & histologia , Acetábulo/cirurgia , Parafusos Ósseos , Cadáver , Radiação Eletromagnética , Estudos de Viabilidade , Fluoroscopia , Fraturas Ósseas/cirurgia , Humanos , Reprodutibilidade dos Testes
11.
Indian J Orthop ; 49(2): 255-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26015619

RESUMO

Crescent fractures of the pelvis are usually described as posterior sacro iliac fracture dislocations. Rarely anterior displacement of the fractured iliac fragment along with dislocation has been reported in crescent fractures. Four cases of anterior fracture dislocation of the sacro iliac joint managed in the last two years by a single surgeon are presented. The injury mechanism, radiological diagnosis, management protocol along with functional outcomes of all the four patients have been discussed. CT scan is essential in the diagnosis and preoperative planning of this injury pattern. Early fixation along with proper reduction leads to excellent functional outcome in this subset of lateral compression injuries of the pelvis.

12.
Traffic Inj Prev ; 16(1): 62-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25261186

RESUMO

OBJECTIVES: Perform a systematic review for the most relevant pelvic injury research involving PMHS. The review begins with an explanation of the pelvic anatomy and a general description of pelvic fracture patterns followed by the particular case of pelvic fractures sustained in pedestrian-vehicle collisions. Field data documenting the vehicle, crash, and human risk factors for pedestrian pelvic injuries are assessed. METHOD: A summary of full-scale PMHS tests and subsystem lateral pelvic tests is provided with an interpretation of the most significant findings for the most relevant studies. CONCLUSIONS: Based on the mechanisms of pedestrian pelvic injury, force, acceleration, and velocity and compression have been assessed as predictive variables by researchers although no consensus criterion exists.


Assuntos
Acidentes de Trânsito/estatística & dados numéricos , Fraturas Ósseas , Ossos Pélvicos/lesões , Caminhada/lesões , Aceleração , Adulto , Condução de Veículo/estatística & dados numéricos , Cadáver , Humanos , Fatores de Risco
13.
Chinese Journal of Trauma ; (12): 521-525, 2015.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-473694

RESUMO

Objective To investigate the clinical value of gauze packing for haemodynamically unstable pelvic fracture.Methods Between January 2006 and January 2014,gauze packing was used to treat haemodynamically unstable pelvic fracture in 42 patients consisting of 23 males and the 19 females aged 34.2 years (range,18 to 54 years).AO classification of the fracture was type B1 in 9,B2 in 5,B3 in 3,C1 in 13,C2 in 4,and C3 in 8 patients.All the patients were diagnosed with hypovolemic shock upon admission with the systolic pressure of (75.4 ± 4.3) mmHg and heart rate of (126.5 ± 12.4) beats/ min.Injury severity score (ISS) was (38.7 ± 6.2)points.Anti-shock treatment,internal or external fixation of pelvic ring,and gauze packing were performed immediately to control the hemorrhage following pelvic fracture.Results Systolic pressure was (95.2 ± 4.6) mmHg and mean heart rate was declined to (85.4 ± 13.2)beats/min after pelvis volume control and gauze packing,with significant differences compared to these preoperatively (P < 0.05).Red blood cell transfusion before internal or external fixation and gauze packing was (15.0 ± 2.4) units versus (8.3 ± 1.5) units within the first postoperative 24 hours (P < 0.05).Twenty-four out of the 42 patients underwent temporary abdominal aorta occlusion.Six patients died postoperatively with the death rate of 14%.Mean time of removing the packing gauze was (51.4 ± 10.3) hours (range,24-168 hours).Conclusion Anti-shock treatment with concurrent gauze packing and pelvis volume control is effective to arrest the massive hemorrhage in hemodynamically unstable pelvic fracture.

15.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-678832

RESUMO

Pelvic fractures are high energy injuries involving severe trauma and potential intra pelvic bleeding. Immediate control of hemorrhage, fixation of pelvic fractures and inter department cooperation are important for their treatment. Transcatheter angiographic embolization can be used to identify bleeding sites, control hemorrhage and improve mortality and complications, and it has been proved to be a valuable technique in the diagnosis and treatment of pelvic vascular injuries. Still there is a considerable controversy on the fracture patterns, the sequence and the timing of emergency angiography and possible embolization in these patients. In this paper, we reviewed the role of angiographic embolization and we thought more attention should be paid on angiographic embolization in the control of hemorrhage.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...