Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 15.958
Filtrar
1.
Ultrasound Med Biol ; 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38955624

RESUMO

OBJECTIVE: Lipomatous soft tissue tumors (STT), ranging from benign lipomas to malignant liposarcomas, require accurate differentiation for timely treatment. Complementary to MRI, Contrast-enhanced ultrasound (CEUS) is emerging as a promising tool, providing insight into tumor microperfusion in real-time. This study aims to explore the potential of preoperative CEUS in differentiating benign lipomatous tumors from malignant liposarcoma subtypes. METHODS: Eighty-seven patients with lipomatous STT scheduled for surgery were enrolled. Clinical and MRI assessments were conducted to obtain general tumor characteristics. CEUS was used for a standardized tumor perfusion evaluation. Perfusion analysis included peak enhancement, rise time, wash-in perfusion index, and wash-out rate, reflecting the perfusion kinetics. Histopathological results were obtained for every STT and compared to perfusion characteristics. RESULTS: In total, 48 lipoma, 23 ALT and 11 liposarcoma were identified. Significant differences in tumor microperfusion were demonstrated, with higher perfusion levels indicating higher malignancy (Peak enhancement [a.u.] of Lipoma: 145 ± 238; ALT: 268 ± 368; Liposarcoma: 3256 ± 4333; p (ALT vs. Liposarcoma) < 0.001). A perfusion-based identification of a benign lipoma or ALT versus sarcoma resulted in a positive predictive value of 93%. Patient-related factors (age, gender, BMI, ASA score, smoking status) had no significant impact on the CEUS-based perfusion parameters. CONCLUSION: Our study suggests CEUS as a capable non-invasive tool for improving preoperative assessment of lipomatous STT. It can assist in the distinction between benign and malignant STT, accelerating treatment decisions and enhancing patient outcomes. Significant correlations between CEUS-derived parameters and malignancy highlight its risk assessment potential.

2.
ESMO Open ; 9(7): 103623, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38959698

RESUMO

BACKGROUND: Uveal melanoma (UM) is a rare malignancy where 50% of patients develop metastatic disease primarily affecting the liver. Approximately 40% of patients with metastatic UM respond to one-time isolated hepatic perfusion (IHP) with high-dose melphalan. This phase I trial investigates the safety and clinical efficacy of IHP combined with ipilimumab (IPI) and nivolumab (NIVO). PATIENTS AND METHODS: Immunotherapy-naïve patients were randomized in this phase I trial to receive either IHP followed by IPI 3 mg/kg and NIVO 1 mg/kg (IPI3/NIVO1) for four cycles (post-operative arm), or one cycle of preoperative IPI3/NIVO1, IHP and then three cycles of IPI3/NIVO1 (pre-post-operative arm), followed by maintenance therapy with NIVO 480 mg for 1 year. RESULTS: Eighteen patients were enrolled and randomized. Three patients did not undergo IHP as planned. In total, 11/18 patients (6 in the post-operative arm and 5 in the pre-post-operative arm) did not complete the planned four cycles of IPI3/NIVO1. Toxicity to IHP was similar in both groups, but the number of immune-related adverse events (AEs) was higher in the pre-post-operative arm. Among assessable patients, overall response rate was 57% in the post-operative arm (4/7) and 22% in the pre-post-operative arm (2/9). CONCLUSIONS: Combination therapy with IHP and IPI3/NIVO1 was associated with severe AEs. The efficacy of this combination is encouraging with high response rates. One cycle of preoperative IPI/NIVO before IHP did not show potential benefits in terms of safety or efficacy.

3.
Z Med Phys ; 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38960810

RESUMO

PURPOSE: To apply velocity selective arterial spin labeling (VSASL) combined with a navigator-based (NAV) prospective motion compensation method for a free-breathing liver perfusion measurement without contrast agent. METHODS: Sinc-modulated Velocity Selective Inversion (sinc-VSI) pulses were applied as labeling and control pulses. In order to account for respiratory motion, a navigator was employed in the form of a single gradient-echo projection readout, located at the diaphragm along the inferior-superior direction. Prior to each transverse imaging slice of the spin-echo EPI based readouts, navigator and fat suppression were incorporated. Motion data was obtained from the navigator and transmitted back to the sequence, allowing real-time adjustments to slice positioning. The sinc-VSI without velocity-selective gradients during the control condition but with velocity-selective gradients along all three directions during labeling was chosen for the VSASL. The VSASL was compared with pseudo-continuous ASL (pCASL) methods, which selectively tagged the moving spins using a tagging plane placed at the portal vein and hepatic artery. RESULTS: The motion caused by respiratory activity was effectively computed using the navigator signal. The coefficients of variation (CoV) of average liver voxel in NAV were significantly decreased when compared to breath-hold (BH), with an average reduction of 29.4 ±â€¯18.44% for control images, and 29.89 ±â€¯20.83% for label images (p < 0.001). The resulting maps of normalized ASL signal (normalized to M0) showed significantly higher perfusion weightings in the NAV-compensated VSASL, when compared to the NAV-compensated pCASL techniques. CONCLUSIONS: This study demonstrates the feasibility of using a navigator-based prospective motion compensation technique in conjunction with VSASL for the measurement of liver perfusion without the use of contrast agents while allowing for free-breathing.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38960945

RESUMO

This study aimed to assess the diagnostic efficacy of left ventricular synchrony (LVS) for detecting coronary artery disease (CAD). We explored whether the LVS index derived from phase analysis of D-SPECT provides superior diagnostic value compared to conventional perfusion analysis in identifying obstructive CAD. Patients with suspected or confirmed CAD underwent drug-stress/rest gated D-SPECT myocardial perfusion imaging (MPI) and coronary angiography (CAG). A 50% stenosis was set as the threshold for obstructive CAD. 110 participants were enrolled in this analysis. There were significant differences in phase standard deviation (PSD), phase histogram bandwidth (PHB) and entropy among the four groups. Patients without cardiac disease and those with mild-moderate stenosis exhibited no noticeable contraction asynchrony. However, LVS indices demonstrated a gradual increase with the progression of coronary stenosis when compared to NC (P < 0.001). Obstructive CAD was identified in 43 out of 110 participants (39%). Optimal cutoff values for diagnosing obstructive CAD during stress were determined as 7.6° for PSD, 24° for PHB, and 37% for entropy, respectively. Notably, PSD, PHB, and entropy indices exhibited higher sensitivity compared to MPI. The integration of the stress-induced LVS indices into routine MPI analysis resulted in a significantly greater area under the curve (AUC), leading to improved diagnostic performance and enhanced differential capacity. Stress-induced LVS indices increase with the severity of coronary artery stenosis by D-SPECT phase analysis. Further, the indices-derived phase analysis exhibits superior sensitivity and discriminatory ability compared to MPI in detecting obstructive CAD.

5.
Vestn Oftalmol ; 140(3): 117-124, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38962987

RESUMO

This review is devoted to the English- and Russian-language terminology of quantitative metrics that are used in the evaluation of images obtained by optical coherence tomography angiography (OCT-A). The paper presents an analysis of the use of terms characterizing intraretinal blood flow (vascular density, perfusion density, skeletonized density, etc.), area and shape of the foveal avascular zone, and choriocapillaris blood flow. The factors causing the heterogeneity of OCT-A terminology are described, including the lack of a unified international nomenclature for OCT-A, features of their Russian translation, inconsistency of the parameters in optical coherence tomography systems of different manufacturers. The article also considers ways to standardize the terminology.


Assuntos
Vasos Retinianos , Tomografia de Coerência Óptica , Tomografia de Coerência Óptica/métodos , Humanos , Vasos Retinianos/diagnóstico por imagem , Terminologia como Assunto , Doenças Retinianas/diagnóstico por imagem , Doenças Retinianas/diagnóstico , Angiofluoresceinografia/métodos , Corioide/irrigação sanguínea , Corioide/diagnóstico por imagem
6.
Future Cardiol ; : 1-12, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38963122

RESUMO

Aim: To evaluate the effects of double (axillary and femoral) vs. single (axillary) cannulation on early outcomes of acute type A aortic dissection (ATAAD). Materials & methods: Meta-analysis using PubMed/MEDLINE, Scopus, and Cochrane databases through August 23, 2023. Focused on operative mortality, postoperative stroke, re-exploration for bleeding, spinal cord injury, and renal replacement therapy. Results: Among 5 propensity score-matched studies with 2127 patients, double cannulation showed comparable mortality and higher rates of postoperative stroke (pooled odds ratio: 1.69, 95% confidence interval: 1.19-2.39) and need for renal replacement therapy (pooled odds ratio: 1.35, 95% confidence interval: 1.13-1.60) compared with single cannulation. Conclusion: Double arterial cannulation in ATAAD surgery is associated with increased postoperative stroke and renal replacement therapy than single cannulation.


What is this summary about? We studied the optimal way to maintain blood flow during surgery for acute aortic dissection. We focused on comparing the use of one tube placement site in the axillary artery with two sites, both in the axillary and femoral arteries, in five previous studies.What were the results? Using two sites was associated with a higher risk of stroke and need for dialysis after surgery than using only one site.What do the results mean? Adding a tube in the femoral artery for blood flow may increase the risk of complications. It appears that placing the tube only in the axillary artery may be a safer choice for appropriately selected patients having this surgery.

7.
EJNMMI Phys ; 11(1): 54, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38951352

RESUMO

BACKGROUND: Several factors may decrease the accuracy of quantitative PET myocardial perfusion imaging (MPI). It is therefore essential to ensure that myocardial blood flow (MBF) values are reproducible and accurate, and to design systematic protocols to achieve this. Until now, no systematic phantom protocols have been available to assess the technical factors affecting measurement accuracy and reproducibility in MPI. MATERIALS AND METHODS: We implemented a standard measurement protocol, which applies a flow phantom in order to compare image-derived flow values with respect to a ground truth flow value with [15O]H2O MPI performed on both a Discovery MI (DMI-20, GE Healthcare) and a Biograph Vision 600 (Vision-600, Siemens Healthineers) system. Both systems have automatic [15O]H2O radio water generators (Hidex Oy) individually installed, allowing us to also study the differences occurring due to two different bolus delivery systems. To investigate the technical factors contributing to the modelled flow values, we extracted the [15O]H2O bolus profiles, the flow values from the kinetic modeling (Qin and Qout), and finally calculated their differences between test-retest measurements on both systems. RESULTS: The measurements performed on the DMI-20 system produced Qin and Qout values corresponging to each other as well as to the reference flow value across all test-retest measurements. The repeatability differences on DMI-20 were 2.1% ± 2.6% and 3.3% ± 4.1% for Qin and Qout, respectively. On Vision-600 they were 10% ± 8.4% and 11% ± 10% for Qin and Qout, respectively. The measurements performed on the Vision-600 system showed more variation between Qin and Qout values across test-retest measurements and exceeded 15% difference in 7/24 of the measurements. CONCLUSIONS: A preliminary protocol for measuring the accuracy and reproducibility of flow values in [15O]H2O MPI between digital PET/CT systems was assessed. The test-retest reproducibility falls below 15% in majority of the measurements conducted between two individual injector systems and two digital PET/CT systems. This study highlights the importance of implementing a standardized bolus injection and delivery protocol and importance of assessing technical factors affecting flow value reproducibility, which should be carefully investigated in a multi-center setting.

8.
BMC Geriatr ; 24(1): 572, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38961397

RESUMO

INTRODUCTION: Aging is associated with a progressive decline in the capacity for physical activity. The objective of the current study was to evaluate the effect of an intermittent hyperbaric oxygen therapy (HBOT) protocol on maximal physical performance and cardiac perfusion in sedentary older adults. METHODS: A randomized controlled clinical trial randomized 63 adults (> 64yrs) either to HBOT (n = 30) or control arms (n = 33) for three months. Primary endpoint included the maximal oxygen consumption (VO2Max) and VO2Max/Kg, on an E100 cycle ergometer. Secondary endpoints included cardiac perfusion, evaluated by magnetic resonance imaging and pulmonary function. The HBOT protocol comprised of 60 sessions administered on a daily basis, for 12 consecutive weeks, breathing 100% oxygen at 2 absolute atmospheres (ATA) for 90 min with 5-minute air breaks every 20 min. RESULTS: Following HBOT, improvements were observed in VO2Max/kg, with a significant increase of 1.91 ± 3.29 ml/kg/min indicated by a net effect size of 0.455 (p = 0.0034). Additionally, oxygen consumption measured at the first ventilatory threshold (VO2VT1) showed a significant increase by 160.03 ± 155.35 ml/min (p < 0.001) with a net effect size of 0.617. Furthermore, both cardiac blood flow (MBF) and cardiac blood volume (MBV) exhibited significant increases when compared to the control group. The net effect size for MBF was large at 0.797 (p = 0.008), while the net effect size for MBV was even larger at 0.896 (p = 0.009). CONCLUSION: The findings of the study indicate that HBOT has the potential to improve physical performance in aging adults. The enhancements observed encompass improvements in key factors including VO2Max, and VO2VT1. An important mechanism contributing to these improvements is the heightened cardiac perfusion induced by HBOT. TRIAL REGISTRATION: ClinicalTrials.gov Identifier NCT02790541 (registration date 06/06/2016).


Assuntos
Oxigenoterapia Hiperbárica , Consumo de Oxigênio , Humanos , Masculino , Feminino , Idoso , Oxigenoterapia Hiperbárica/métodos , Consumo de Oxigênio/fisiologia , Pessoa de Meia-Idade , Exercício Físico/fisiologia
9.
Front Vet Sci ; 11: 1406343, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38966564

RESUMO

Introduction: Dynamic contrast-enhanced (DCE) MRI and arterial spin labeling (ASL) MRI enable non-invasive measurement of renal blood flow (RBF), whereas blood oxygenation level-dependent (BOLD) MRI enables non-invasive measurement of the apparent relaxation rate (R2*), an indicator of oxygenation. This study was conducted to evaluate the potential role of these MRI modalities in assessing RBF and oxygenation in dogs. The correlation between contrast-enhanced ultrasound (CEUS) and the MRI modalities was examined and also the ability of the MRI modalities to detect pharmacologically induced changes. Methods: RBF, using CEUS, ASL- and DCE-MRI, as well as renal oxygenation, using BOLD-MRI of eight adult beagles were assessed at two time-points, 2­3 weeks apart. During each time point, the anesthetized dogs received either a control (0.9% sodium chloride) or a dopamine treatment. For each time point, measurements were carried out over 2 days. An MRI scan at 3 T was performed on day one, followed by CEUS on day two. Results: Using the model-free model with caudal placement of the arterial input function (AIF) region of interest (ROI) in the aorta, the DCE results showed a significant correlation with ASL measured RBF and detected significant changes in blood flow during dopamine infusion. Additionally, R2* negatively correlated with ASL measured RBF at the cortex and medulla, as well as with medullary wash-in rate (WiR) and peak intensity (PI). ASL measured RBF, in its turn, showed a positive correlation with cortical WiR, PI, area under the curve (AUC) and fall time (FT), and with medullary WiR and PI, but a negative correlation with medullary rise time (RT). During dopamine infusion, BOLD-MRI observed a significant decrease in R2* at the medulla and entire kidney, while ASL-MRI demonstrated a significant increase in RBF at the cortex, medulla and the entire kidney. Conclusion: ASL- and BOLD-MRI can measure pharmacologically induced changes in renal blood flow and renal oxygenation in dogs and might allow detection of changes that cannot be observed with CEUS. However, further research is needed to confirm the potential of ASL- and BOLD-MRI in dogs and to clarify which analysis method is most suitable for DCE-MRI in dogs.

10.
Front Cardiovasc Med ; 11: 1395036, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38966750

RESUMO

Background: The diagnosis of coronary microvascular disease (CMVD) remains challenging. Perfusion PET-derived myocardial blood flow (MBF) reserve (MBFR) can quantify CMVD but is not widely available. Thrombolysis in Myocardial Infarction (TIMI) frame count (TFC) is an angiography-based method that has been proposed as a measure of CMVD. Here, we compare TFC and PET-derived MBF measurements to establish the role of TFC in assessing for CMVD. We use coronary modeling to elucidate the relationship between MBFR and TFC and propose TFC thresholds for identifying CMVD. Methods: In a cohort of 123 individuals (age 58 ± 12.1, 63% women, 41% Caucasian) without obstructive coronary artery disease who had undergone perfusion PET and coronary angiography for clinical indications, we compared TFC and perfusion PET parameters using Pearson correlation (PCC) and linear regression modeling. We used mathematical modeling of the coronary circulation to understand the relationship between these parameters and performed Receiver Operating Curve (ROC) analysis. Results: We found a significant negative correlation between TFC and MBFR. Sex, race and ethnicity, and nitroglycerin administration impact this relationship. Coronary modeling showed an uncoupling between TFC and flow in epicardial vessels. In ROC analysis, TFC performed well in women (AUC 0.84-0.89) and a moderately in men (AUC 0.68-0.78). Conclusions: We established an inverse relationship between TFC and PET-derived MBFR, which is affected by patient selection and procedural factors. TFC represents a measure of the volume of the epicardial coronary compartment, which is increased in patients with CMVD, and performs well in identifying women with CMVD.

11.
J Neurointerv Surg ; 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38969496

RESUMO

BACKGROUND: The DEFUSE 3 and SELECT2 thrombectomy trials included some patients with similar radiographic profiles, although the rates of good functional outcomes differed widely between the studies. OBJECTIVE: To report neurological outcomes for patients who meet CT and CT perfusion (CTP) inclusion criteria common to both DEFUSE 3 and SELECT2. METHODS: Retrospective study of thrombectomy patients, presenting between November 2016 and December 2023 to a large health system, with Alberta Stroke Program Early CT score ≥6, core infarction 50-69 mL, mismatch ratio ≥1.8, and mismatch volume ≥15 mL. The primary outcome was 90-day modified Rankin Scale score 0-2. A logistic regression analysis was performed to identify independent predictors of the primary outcome. RESULTS: 85 patients, with mean age 64.6 (16.6) years and median National Institutes of Health Stroke Scale score 18 (15-23), were included. Thirty-eight of 85 patients (44.7%) were functionally independent at 90 days. Predictors of functional independence included age (OR=0.943, 95% CI 0.908 to 0.980; P=0.003), initial glucose (OR=0.989, 95% CI 0.978 to 1.000; P=0.044), and time last known well to skin puncture (OR=0.997, 95% CI 0.994 to 1.000; P=0.028). The area under the curve for the multivariable model predicting the primary outcome was 0.82 (95% CI 0.73 to 0.92). CONCLUSION: Nearly half of patients meeting radiographic criteria common to DEFUSE 3 and SELECT2 are functionally independent at 90 days, similar to rates reported for the treated DEFUSE 3 cohort. This might be due to their moderate core volumes and large ischemic penumbra.

12.
Cureus ; 16(6): e61591, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38962639

RESUMO

Background Early treatment of intracranial lesions in the emergency department is crucial, but it can be challenging to differentiate between them. This differentiation is essential because the treatment of each type of lesion is different. Cerebral computed tomography perfusion (CTP) imaging can help visualize the vascularity of brain lesions and provide absolute quantification of physiological parameters. Compared to magnetic resonance imaging, CTP has several advantages, such as simplicity, wide availability, and reproducibility. Purpose This study aimed to assess the effectiveness of Hounsfield units (HU) in measuring the density of hypercellular lesions and the ability of CTP to quantify hemodynamics in distinguishing intracranial space-occupying lesions. Methods A retrospective study was conducted from March 2016 to March 2022. All patients underwent CTP and CT scans, and relative cerebral blood volume (rCBV) and HU were obtained for intracranial lesions. Results We included a total of 244 patients in our study. This group consisted of 87 (35.7%) individuals with glioblastomas (GBs), 48 (19.7%) with primary central nervous system lymphoma (PCNSL), 45 (18.4%) with metastases (METs), and 64 (26.2) with abscesses. Our study showed that the HUs for METs were higher than those for GB (S 57.4% and E 88.5%). In addition, rCBV values for PCNSL and abscesses were lower than those for GB and METs. The HU in PCNSL was higher than those in abscesses (S 94.1% and E 96.6%). Conclusion PCT parameters provide valuable information for diagnosing brain lesions. A comprehensive assessment improves accuracy. Combining rCBV and HU enhances diagnostic accuracy, making it a valuable tool for distinguishing between lesions. PCT's widespread availability allows for the use of both anatomical and functional information with high spatial resolution for diagnosing and managing brain tumor patients.

13.
Artigo em Inglês | MEDLINE | ID: mdl-38965165

RESUMO

PURPOSE: Cardiac perfusion MRI is vital for disease diagnosis, treatment planning, and risk stratification, with anomalies serving as markers of underlying ischemic pathologies. AI-assisted methods and tools enable accurate and efficient left ventricular (LV) myocardium segmentation on all DCE-MRI timeframes, offering a solution to the challenges posed by the multidimensional nature of the data. This study aims to develop and assess an automated method for LV myocardial segmentation on DCE-MRI data of a local hospital. METHODS: The study consists of retrospective DCE-MRI data from 55 subjects acquired at the local hospital using a 1.5 T MRI scanner. The dataset included subjects with and without cardiac abnormalities. The timepoint for the reference frame (post-contrast LV myocardium) was identified using standard deviation across the temporal sequences. Iterative image registration of other temporal images with respect to this reference image was performed using Maxwell's demons algorithm. The registered stack was fed to the model built using the U-Net framework for predicting the LV myocardium at all timeframes of DCE-MRI. RESULTS: The mean and standard deviation of the dice similarity coefficient (DSC) for myocardial segmentation using pre-trained network Net_cine is 0.78 ± 0.04, and for the fine-tuned network Net_dyn which predicts mask on all timeframes individually, it is 0.78 ± 0.03. The DSC for Net_dyn ranged from 0.71 to 0.93. The average DSC achieved for the reference frame is 0.82 ± 0.06. CONCLUSION: The study proposed a fast and fully automated AI-assisted method to segment LV myocardium on all timeframes of DCE-MRI data. The method is robust, and its performance is independent of the intra-temporal sequence registration and can easily accommodate timeframes with potential registration errors.

14.
J Surg Res ; 301: 248-258, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38970873

RESUMO

INTRODUCTION: Normothermic machine perfusion (NMP) of donor kidneys provides the opportunity to assess and improve organ viability prior to transplantation. This study explored the necessity of an oxygen carrier during NMP and whether the hemoglobin-based oxygen carrier (HBOC-201) is a suitable alternative to red blood cells (RBCs). METHODS: Porcine kidneys were perfused with a perfusion solution containing either no-oxygen carrier, RBCs, or HBOC-201 for 360 min at 37°C. RESULTS: Renal flow and resistance did not differ significantly between groups. NMP without an oxygen carrier showed lower oxygen consumption with higher lactate and aspartate aminotransferase levels, indicating that the use of an oxygen carrier is necessary for NMP. Cumulative urine production and creatinine clearance in the RBC group were significantly higher than in the HBOC-201 group. Oxygen consumption, injury markers, and histology did not differ significantly between these two groups. However, methemoglobin levels increased to 45% after 360 min in the HBOC-201 group. CONCLUSIONS: We conclude that HBOC-201 could be used as an alternative for RBCs, but accumulating methemoglobin levels during our perfusions indicated that HBOC-201 is probably less suitable for prolonged NMP. Perfusion with RBCs, compared to HBOC-201, resulted in more favorable renal function during NMP.

15.
Eur J Radiol ; 177: 111595, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38970994

RESUMO

PURPOSE: CT perfusion (CTP) is a valuable tool in suspected acute ischemic stroke. A substantial variability of the delay between contrast injection and bolus arrival in the brain is conceivable. We investigated the distribution of the peak positions of the concentration time curves measured in an artery (arterial input function, AIF) and - in cases with ischemia - also measured in the penumbra. METHODS: We report on 2624 perfusion scans (52 % female, mean age 72.2 ± 14.4 years) with stroke present in 1636 cases. From the attenuation time curves of the AIF and the penumbra, we calculated the respective bolus peak positions and investigated the distribution of the peak positions. Further, we analyzed the bolus peak positions for associations with age. RESULTS: The bolus peaked significantly later in older patients, both in the AIF and in the penumbra (all p < 0.001). In the whole cohort, we found a significant association of age with the bolus peak position of the AIF (ρ = 0.334; p < 0.001). In patients with stroke, age was also associated to the peak position of the AIF (ρ = 0.305; p < 0.001), and the penumbra (ρ = 0.246, p < 0.001). However, a substantial range of peak positions of the AIF and penumbra was noted across all age ranges. CONCLUSIONS: This study revealed a strong age-dependency of the contrast bolus arrival in both healthy and ischemic tissue. This variability makes non-uniform sampling schemes, which have been suggested to reduce radiation dose, problematic, as they might not always optimally capture the bolus in all cases.

16.
Biosens Bioelectron ; 262: 116549, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38971037

RESUMO

Continuous oxygenation monitoring of machine-perfused organs or transposed autologous tissue is not currently implemented in clinical practice. Oxygenation is a critical parameter that could be used to verify tissue viability and guide corrective interventions, such as perfusion machine parameters or surgical revision. This work presents an innovative technology based on oxygen-sensitive, phosphorescent metalloporphyrin allowing continuous and non-invasive oxygen monitoring of ex-vivo perfused vascularized fasciocutaneous flaps. The method comprises a small, low-energy optical transcutaneous oxygen sensor applied on the flap's skin paddle as well as oxygen sensing devices placed into the tubing. An intermittent perfusion setting was designed to study the response time and accuracy of this technology over a total of 54 perfusion cycles. We further evaluated correlation between the continuous oxygen measurements and gold-standard perfusion viability metrics such as vascular resistance, with good agreement suggesting potential to monitor graft viability at high frequency, opening the possibility to employ feedback control algorithms in the future. This proof-of-concept study opens a range of research and clinical applications in reconstructive surgery and transplantation at a time when perfusion machines undergo rapid clinical adoption with potential to improve outcomes across a variety of surgical procedures and dramatically increase access to transplant medicine.

17.
J Foot Ankle Surg ; 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38964708

RESUMO

The aim of the study was to compare preoperative factors and postoperative outcomes in patients with heel ulcerations that primarily had a transtibial (below the knee) amputation (N=38) versus vertical contour calcanectomy (n=62). The groups had no statistical difference between their Charlson Comorbidity Index Score, a prognostic score of ten-year survival in patients with multiple comorbidities. The odds of primary closure was 21.1 times higher in patients that underwent below knee amputation compared to patients that underwent vertical contour calcanectomy [OR 21.1 (95% CI 3.89-114.21)]. The odds of positive soft tissue culture at time of closure were 17.1 times higher for patients that underwent vertical contour calcanectomy [OR 17.1 (95% CI 5.40-54.16)]. The odds of a patent posterior tibial artery was 3.3 times higher for patients that underwent vertical contour calcanectomy [OR 3.3 (95% 1.09-10.09)]. The secondary aim of the study was to evaluate preoperative factors and postoperative outcomes in patients with failed vertical contour calcanectomy, defined as needing a below knee amputation. The odds of vertical contour calcanectomy failure was 13.7 times higher in male patients [OR 13.7 (95% CI 1.80-107.60)]. Vertical contour calcanectomy failure was 5.7 times higher in patients with renal disease [OR 5.7 (95% CI 1.10-30.30)], and vertical contour calcanectomy failure was 16.1 times higher for patients who needed additional surgery post closure [OR 16.1 (95% CI 1.40-183.20)].

18.
Eur Radiol ; 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38967660

RESUMO

PURPOSE: To evaluate the quality of lung perfusion imaging obtained with photon-counting-detector CT (PCD-CT) in comparison with dual-source, dual-energy CT (DECT). METHODS: Seventy-one consecutive patients scanned with PCD-CT were compared to a paired population scanned with dual-energy on a 3rd-generation DS-CT scanner using (a) for DS-CT (Group 1): collimation: 64 × 0.6 × 2 mm; pitch: 0.55; (b) for PCD-CT (Group 2): collimation: 144 × 0.4 mm; pitch: 1.5; single-source acquisition. The injection protocol was similar in both groups with the reconstruction of perfusion images by subtraction of high- and low-energy virtual monoenergetic images. RESULTS: Compared to Group 1, Group 2 examinations showed: (a) a shorter duration of data acquisition (0.93 ± 0.1 s vs 3.98 ± 0.35 s; p < 0.0001); (b) a significantly lower dose-length-product (172.6 ± 55.14 vs 339.4 ± 75.64 mGy·cm; p < 0.0001); and (c) a higher level of objective noise (p < 0.0001) on mediastinal images. On perfusion images: (a) the mean level of attenuation did not differ (p = 0.05) with less subjective image noise in Group 2 (p = 0.049); (b) the distribution of scores of fissure visualization differed between the 2 groups (p < 0.0001) with a higher proportion of fissures sharply delineated in Group 2 (n = 60; 84.5% vs n = 26; 26.6%); (c) the rating of cardiac motion artifacts differed between the 2 groups (p < 0.0001) with a predominance of examinations rated with mild artifacts in Group 2 (n = 69; 97.2%) while the most Group 1 examinations showed moderate artifacts (n = 52; 73.2%). CONCLUSION: PCD-CT acquisitions provided similar morphologic image quality and superior perfusion imaging at lower radiation doses. CLINICAL RELEVANCE STATEMENT: The improvement in the overall quality of perfusion images at lower radiation doses opens the door for wider applications of lung perfusion imaging in clinical practice. KEY POINTS: The speed of data acquisition with PCD-CT accounts for mild motion artifacts. Sharply delineated fissures are depicted on PCD-CT perfusion images. High-quality perfusion imaging was obtained with a 52% dose reduction.

19.
J Anesth Analg Crit Care ; 4(1): 40, 2024 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-38971842

RESUMO

BACKGROUND: Lung perfusion defects, mainly due to endothelial and coagulation activation, are a key contributor to COVID-19 respiratory failure. COVID-19 patients may also develop acute kidney injury (AKI) because of renal perfusion deficit. We aimed to explore AKI-associated factors and the independent prediction of standardized minute ventilation (MV)-a proxy of alveolar dead space-on AKI onset and persistence in COVID-19 mechanically ventilated patients. METHODS: This is a multicenter observational cohort study. We enrolled 157 COVID-19 patients requiring mechanical ventilation and intensive care unit (ICU) admission. We collected clinical information, ventilation, and laboratory data. AKI was defined by the 2012 KDIGO guidelines and classified as transient or persistent according to serum creatinine criteria persistence within 48 h. Ordered univariate and multivariate logistic regression analyses were employed to identify variables associated with AKI onset and persistence. RESULTS: Among 157 COVID-19 patients on mechanical ventilation, 47% developed AKI: 10% had transient AKI, and 37% had persistent AKI. The degree of hypoxia was not associated with differences in AKI severity. Across increasing severity of AKI groups, despite similar levels of paCO2, we observed an increased MV and standardized MV, a robust proxy of alveolar dead space. After adjusting for other clinical and laboratory covariates, standardized MV remained an independent predictor of AKI development and persistence. D-dimer levels were higher in patients with persistent AKI. CONCLUSIONS: In critically ill COVID-19 patients with respiratory failure, increased wasted ventilation is independently associated with a greater risk of persistent AKI. These hypothesis-generating findings may suggest that perfusion derangements may link the pathophysiology of both wasted ventilation and acute kidney injury in our population.

20.
Diabetes Res Clin Pract ; : 111772, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38972600

RESUMO

INTRODUCTION: Diabetes Mellitus (DM) is a common chronic disease, affecting 435 million people globally. Impaired vasculature in DM patients leads to complications like lower extremity arterial disease (LEAD) and foot ulcers, often resulting in amputations. DM causes additional peripheral neuropathy leading to multifactorial wound problems. Current diagnostics often deem unreliable, but Near-Infrared Fluorescence with Indocyanine Green (ICG NIR) can be used to assess the foot perfusion. Therefore, this study explores DM's impact on foot perfusion using ICG NIR. METHODS: Baseline ICG NIR fluorescence imaging was performed in LEAD patients with and without DM. Ten perfusion parameters were extracted and analyzed to assess differences in perfusion patterns. RESULTS: Among 109 patients (122 limbs) of the included patients, 32.8% had DM. Six of ten perfusion parameters, mainly inflow-related, differed significantly between DM and non-DM patients (p-values 0.007-0.039). Fontaine stage 4 DM patients had the highest in- and outflow values, with seven parameters significantly higher (p-values 0.004-0.035). CONCLUSION: DM is associated with increased in- and outflow parameters. Patients with- and without DM should not be compared directly due to different vascular pathophysiology and multifactorial wound problems in DM patients. Quantified ICG NIR fluorescence imaging offers additional insight into the effect of DM on foot perfusion.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...