Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 131
Filtrar
1.
Eur Radiol Exp ; 8(1): 78, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38955951

RESUMO

BACKGROUND: Computed tomography (CT) is the usual modality for diagnosing stroke, but conventional CT angiography reconstructions have limitations. METHODS: A phantom with tubes of known diameters and wall thickness was scanned for wall detectability, wall thickness, and contrast-to-noise ratio (CNR) on conventional and spectral black-blood (SBB) images. The clinical study included 34 stroke patients. Diagnostic certainty and conspicuity of normal/abnormal intracranial vessels using SBB were compared to conventional. Sensitivity/specificity/accuracy of SBB and conventional were compared for plaque detectability. CNR of the wall/lumen and quantitative comparison of remodeling index, plaque burden, and eccentricity were obtained for SBB imaging and high-resolution magnetic resonance imaging (hrMRI). RESULTS: The phantom study showed improved detectability of tube walls using SBB (108/108, 100% versus conventional 81/108, 75%, p < 0.001). CNRs were 75.9 ± 62.6 (mean ± standard deviation) for wall/lumen and 22.0 ± 17.1 for wall/water using SBB and 26.4 ± 15.3 and 101.6 ± 62.5 using conventional. Clinical study demonstrated (i) improved certainty and conspicuity of the vessels using SBB versus conventional (certainty, median score 3 versus 0; conspicuity, median score 3 versus 1 (p < 0.001)), (ii) improved sensitivity/specificity/accuracy of plaque (≥ 1.0 mm) detectability (0.944/0.981/0.962 versus 0.239/0.743/0.495) (p < 0.001), (iii) higher wall/lumen CNR of SBB of (78.3 ± 50.4/79.3 ± 96.7) versus hrMRI (18.9 ± 8.4/24.1 ± 14.1) (p < 0.001), and (iv) excellent reproducibility of remodeling index, plaque burden, and eccentricity using SBB versus hrMRI (intraclass correlation coefficient 0.85-0.94). CONCLUSIONS: SBB can enhance the detectability of intracranial plaques with an accuracy similar to that of hrMRI. RELEVANCE STATEMENT: This new spectral black-blood technique for the detection and characterization of intracranial vessel atherosclerotic disease could be a time-saving and cost-effective diagnostic step for clinical stroke patients. It may also facilitate prevention strategies for atherosclerosis. KEY POINTS: • Blooming artifacts can blur vessel wall morphology on conventional CT angiography. • Spectral black-blood (SBB) images are generated from material decomposition from spectral CT. • SBB images reduce blooming artifacts and noise and accurately detect small plaques.


Assuntos
Arteriosclerose Intracraniana , Imagens de Fantasmas , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Arteriosclerose Intracraniana/diagnóstico por imagem , Idoso , Angiografia por Tomografia Computadorizada/métodos , Sensibilidade e Especificidade , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
2.
Eur Radiol Exp ; 8(1): 69, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38862843

RESUMO

BACKGROUND: Dual-energy computed tomography (DECT) is useful for detecting gouty tophi. While iodinated contrast media (ICM) might enhance the detection of monosodium urate crystals (MSU), higher iodine concentrations hamper their detection. Calculating virtual noncontrast (VNC) images might improve the detection of enhancing tophi. The aim of this study was to evaluate MSU detection with VNC images from DECT acquisitions in phantoms, compared against the results with standard DECT reconstructions. METHODS: A grid-like and a biophantom with 25 suspensions containing different concentrations of ICM (0 to 2%) and MSU (0 to 50%) were scanned with sequential single-source DECT using an ascending order of tube current time product at 80 kVp (16.5-220 mAs) and 135 kVp (2.75-19.25 mAs). VNC images were equivalently reconstructed at 80 and 135 kVp. Two-material decomposition analysis for MSU detection was applied for the VNC and conventional CT images. MSU detection and attenuation values were compared in both modalities. RESULTS: For 0, 0.25, 0.5, 1, and 2% ICM, the average detection indices (DIs) for all MSU concentrations (35-50%) with VNC postprocessing were respectively 25.2, 36.6, 30.9, 38.9, and 45.8% for the grid phantom scans and 11.7, 9.4, 5.5, 24.0, and 25.0% for the porcine phantom scans. In the conventional CT image group, the average DIs were respectively 35.4, 54.3, 45.4, 1.0, and 0.0% for the grid phantom and 19.4, 17.9, 3.0, 0.0, and 0.0% for the porcine phantom scans. CONCLUSIONS: VNC effectively reduces the suppression of information caused by high concentrations of ICM, thereby improving the detection of MSU. RELEVANCE STATEMENT: Contrast-enhanced DECT alone may suffice for diagnosing gout without a native acquisition. KEY POINTS: • Highly concentrated contrast media hinders monosodium urate crystal detection in CT imaging • Virtual noncontrast imaging redetects monosodium urate crystals in high-iodinated contrast media concentrations. • Contrast-enhanced DECT alone may suffice for diagnosing gout without a native acquisition.


Assuntos
Meios de Contraste , Gota , Imagens de Fantasmas , Tomografia Computadorizada por Raios X , Ácido Úrico , Tomografia Computadorizada por Raios X/métodos , Ácido Úrico/análise , Gota/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Animais , Suínos
3.
Eur Radiol Exp ; 8(1): 49, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38622388

RESUMO

BACKGROUND: Automatic exposure control (AEC) plays a crucial role in mammography by determining the exposure conditions needed to achieve specific image quality based on the absorption characteristics of compressed breasts. This study aimed to characterize the behavior of AEC for digital mammography (DM), digital breast tomosynthesis (DBT), and low-energy (LE) and high-energy (HE) acquisitions used in contrast-enhanced mammography (CEM) for three mammography systems from two manufacturers. METHODS: Using phantoms simulating various breast thicknesses, 363 studies were acquired using all available AEC modes 165 DM, 132 DBT, and 66 LE-CEM and HE-CEM. AEC behaviors were compared across systems and modalities to assess the impact of different technical components and manufacturers' strategies on the resulting mean glandular doses (MGDs) and image quality metrics such as contrast-to-noise ratio (CNR). RESULTS: For all systems and modalities, AEC increased MGD for increasing phantom thicknesses and decreased CNR. The median MGD values (interquartile ranges) were 1.135 mGy (0.772-1.668) for DM, 1.257 mGy (0.971-1.863) for DBT, 1.280 mGy (0.937-1.878) for LE-CEM, and 0.630 mGy (0.397-0.713) for HE-CEM. Medians CNRs were 14.2 (7.8-20.2) for DM, 4.91 (2.58-7.20) for a single projection in DBT, 11.9 (8.0-18.2) for LE-CEM, and 5.2 (3.6-9.2) for HE-CEM. AECs showed high repeatability, with variations lower than 5% for all modes in DM, DBT, and CEM. CONCLUSIONS: The study revealed substantial differences in AEC behavior between systems, modalities, and AEC modes, influenced by technical components and manufacturers' strategies, with potential implications in radiation dose and image quality in clinical settings. RELEVANCE STATEMENT: The study emphasized the central role of automatic exposure control in DM, DBT, and CEM acquisitions and the great variability in dose and image quality among manufacturers and between modalities. Caution is needed when generalizing conclusions about differences across mammography modalities. KEY POINTS: • AEC plays a crucial role in DM, DBT, and CEM. • AEC determines the "optimal" exposure conditions needed to achieve specific image quality. • The study revealed substantial differences in AEC behavior, influenced by differences in technical components and strategies.


Assuntos
Mamografia , Intensificação de Imagem Radiográfica , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Mamografia/métodos , Imagens de Fantasmas
4.
Eur Radiol Exp ; 8(1): 19, 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38347188

RESUMO

BACKGROUND: A dual-function phantom designed to quantify the apparent diffusion coefficient (ADC) in different fat contents (FCs) and glass bead densities (GBDs) to simulate the human tissues has not been documented yet. We propose a dual-function phantom to quantify the FC and to measure the ADC at different FCs and different GBDs. METHODS: A fat-containing diffusion phantom comprised by 30 glass-bead-containing fat-water emulsions consisting of six different FCs (0, 10, 20, 30, 40, and 50%) multiplied by five different GBDs (0, 0.1, 0.25, 0.5, and 1.0 g/50 mL). The FC and ADC were measured by the "iterative decomposition of water and fat with echo asymmetry and least squares estimation-IQ," IDEAL-IQ, and single-shot echo-planar diffusion-weighted imaging, SS-EP-DWI, sequences, respectively. Linear regression analysis was used to evaluate the relationship among the fat fraction (FF) measured by IDEAL-IQ, GBD, and ADC. RESULTS: The ADC was significantly, negatively, and linearly associated with the FF (the linear slope ranged from -0.005 to -0.017, R2 = 0.925 to 0.986, all p < 0.001). The slope of the linear relationship between the ADC and the FF, however, varied among different GBDs (the higher the GBD, the lower the slope). ADCs among emulsions across different GBDs and FFs were overlapped. Emulsions with low GBDs plus high FFs shared a same lower ADC range with those with median or high GBDs plus median or lower FFs. CONCLUSIONS: A novel dual-function phantom simulating the human tissues allowed to quantify the influence of FC and GBD on ADC. RELEVANCE STATEMENT: The study developed an innovative dual-function MRI phantom to explore the impact of FC on ADC variation that can affect clinical results. The results revealed the superimposed effect on FF and GBD density on ADC measurements. KEY POINTS: • A dual-function phantom made of glass bead density (GBD) and fat fraction (FF) emulsion has been developed. • Apparent diffusion coefficient (ADC) values are determined by GBD and FF. • The dual-function phantom showed the mutual ADC addition between FF and GBD.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imageamento por Ressonância Magnética , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar , Água , Imagens de Fantasmas
5.
Int J Cardiovasc Imaging ; 40(4): 931-940, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38386192

RESUMO

Virtual mono-energetic images (VMI) using dual-layer computed tomography (DLCT) enable substantial contrast medium (CM) reductions. However, the combined impact of patient size, tube voltage, and heart rate (HR) on VMI of coronary CT angiography (CCTA) remains unknown. This phantom study aimed to assess VMI levels achieving comparable contrast-to-noise ratio (CNR) in CCTA at 50% CM dose across varying tube voltages, patient sizes, and HR, compared to the reference protocol (100% CM dose, conventional at 120 kVp). A 5 mm artificial coronary artery with 100% (400 HU) and 50% (200 HU) iodine CM-dose was positioned centrally in an anthropomorphic thorax phantom. Horizontal coronary movement was matched to HR (at 0, < 60, 60-75, > 75 bpm), with varying patient sizes simulated using phantom extension rings. Raw data was acquired using a clinical CCTA protocol at 120 and 140 kVp (five repetitions). VMI images (40-70 keV, 5 keV steps) were then reconstructed; non-overlapping 95% CNR confidence intervals indicated significant differences from the reference. Higher CM-dose, reduced VMI, slower HR, higher tube voltage, and smaller patient sizes demonstrated a trend of higher CNR. Regardless of HR, patient size, and tube voltage, no significant CNR differences were found compared to the reference, with 100% CM dose at 60 keV, or 50% CM dose at 40 keV. DLCT reconstructions at 40 keV from 120 to 140 kVp acquisitions facilitate 50% CM dose reduction for various patient sizes and HR with equivalent CNR to conventional CCTA at 100% CM dose, although clinical validation is needed.


Assuntos
Angiografia por Tomografia Computadorizada , Meios de Contraste , Angiografia Coronária , Vasos Coronários , Frequência Cardíaca , Imagens de Fantasmas , Valor Preditivo dos Testes , Doses de Radiação , Humanos , Angiografia Coronária/instrumentação , Angiografia Coronária/métodos , Angiografia por Tomografia Computadorizada/instrumentação , Meios de Contraste/administração & dosagem , Vasos Coronários/diagnóstico por imagem , Exposição à Radiação/prevenção & controle , Interpretação de Imagem Radiográfica Assistida por Computador , Tamanho Corporal
6.
Eur Radiol Exp ; 7(1): 59, 2023 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-37875769

RESUMO

BACKGROUND: Photon-counting detector computed tomography (PCD-CT) may influence imaging characteristics for various clinical conditions due to higher signal and contrast-to-noise ratio in virtual monoenergetic images (VMI). Radiomics analysis relies on quantification of image characteristics. We evaluated the impact of different VMI reconstructions on radiomic features in in vitro and in vivo PCD-CT datasets. METHODS: An organic phantom consisting of twelve samples (four oranges, four onions, and four apples) was scanned five times. Twenty-three patients who had undergone coronary computed tomography angiography on a first generation PCD-CT system with the same image acquisitions were analyzed. VMIs were reconstructed at 6 keV levels (40, 55, 70, 90, 120, and 190 keV). The phantoms and the patients' left ventricular myocardium (LVM) were segmented for all reconstructions. Ninety-three original radiomic features were extracted. Repeatability and reproducibility were evaluated through intraclass correlations coefficient (ICC) and post hoc paired samples ANOVA t test. RESULTS: There was excellent repeatability for radiomic features in phantom scans (all ICC = 1.00). Among all VMIs, 36/93 radiomic features (38.7%) in apples, 28/93 (30.1%) in oranges, and 33/93 (35.5%) in onions were not significantly different. For LVM, the percentage of stable features was high between VMIs ≥ 90 keV (90 versus 120 keV, 77.4%; 90 versus 190 keV, 83.9%; 120 versus 190 keV, 89.3%), while comparison to lower VMI levels led to fewer reproducible features (40 versus 55 keV, 8.6%). CONCLUSIONS: VMI levels influence the stability of radiomic features in an organic phantom and patients' LVM; stability decreases considerably below 90 keV. RELEVANCE STATEMENT: Spectral reconstructions significantly influence radiomic features in vitro and in vivo, necessitating standardization and careful attention to these reconstruction parameters before clinical implementation. KEY POINTS: • Radiomic features have an excellent repeatability within the same PCD-CT acquisition and reconstruction. • Differences in VMI lead to decreased reproducibility for radiomic features. • VMI ≥ 90 keV increased the reproducibility of the radiomic features.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Miocárdio
7.
Medicina (Kaunas) ; 59(9)2023 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-37763796

RESUMO

Background and Objectives: We attempted to determine the optimal radiation dose to maintain image quality using a deep learning application in a physical human phantom. Materials and Methods: Three 5 × 5 × 5 mm3 uric acid stones were placed in a physical human phantom in various locations. Three tube voltages (120, 100, and 80 kV) and four current-time products (100, 70, 30, and 15 mAs) were implemented in 12 scans. Each scan was reconstructed with filtered back projection (FBP), statistical iterative reconstruction (IR, iDose), and knowledge-based iterative model reconstruction (IMR). By applying deep learning to each image, we took 12 more scans. Objective image assessments were calculated using the standard deviation of the Hounsfield unit (HU). Subjective image assessments were performed by one radiologist and one urologist. Two radiologists assessed the subjective assessment and found the stone under the absence of information. We used this data to calculate the diagnostic accuracy. Results: Objective image noise was decreased after applying a deep learning tool in all images of FBP, iDose, and IMR. There was no statistical difference between iDose and deep learning-applied FBP images (10.1 ± 11.9, 9.5 ± 18.5 HU, p = 0.583, respectively). At a 100 kV-30 mAs setting, deep learning-applied FBP obtained a similar objective noise in approximately one third of the radiation doses compared to FBP. In radiation doses with settings lower than 100 kV-30 mAs, the subject image assessment (image quality, confidence level, and noise) showed deteriorated scores. Diagnostic accuracy was increased when the deep learning setting was lower than 100 kV-30 mAs, except for at 80 kV-15 mAs. Conclusions: At the setting of 100 kV-30 mAs or higher, deep learning-applied FBP did not differ in image quality compared to IR. At the setting of 100 kV-30 mAs, the radiation dose can decrease by about one third while maintaining objective noise.


Assuntos
Aprendizado Profundo , Urolitíase , Humanos , Urolitíase/diagnóstico por imagem , Processos Mentais , Tomografia Computadorizada por Raios X
8.
Eur Radiol Exp ; 7(1): 43, 2023 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-37486463

RESUMO

BACKGROUND: To investigate the influence of iodinated contrast medium (ICM) on detection of monosodium urate (MSU) with dual-energy computed tomography (DECT) in two types of phantoms and demonstrate an example patient for clinical illustration. METHODS: Approval is by the institutional review board, and written informed consent was obtained. A grid-like and a biophantom with 25 suspensions containing different concentrations of ICM (0 to 2%) and MSU (0 to 50%) were prepared and scanned with sequential single-source DECT using established methodology. Ascending orders of tube currents were applied at 80 kVp (16.5 to 220.0 mAs) and 135 kVp (2.75 to 19.25 mAs). Volume and mass measurements were performed using clinical gout software (dual-energy decomposition analysis). Numbers of true-positive and false-positive MSU detections were recorded and compared for different ICM concentrations. We demonstrate a patient with gouty arthritis for clinical illustration. RESULTS: Effects of ICM on MSU detection varied with the amount of iodine. Lower ICM concentrations (0.25 and 0.50%) improved detection of small uric acid concentrations of 35 to 45% in comparison to scans without ICM. However, high ICM concentrations (1 and 2%) almost completely precluded MSU detection for all MSU concentrations investigated. In a patient with gouty arthritis, tophi in the wrist were only detected after intravenous ICM administration. CONCLUSIONS: Exploring multimodal DECT for arthritis imaging, enhancement of ICM influences tophus detection. It can help in visualizing previously undetected MSU depositions but, with too strong enhancement, also obscure tophi. RELEVANCE STATEMENT: Use of iodinated contrast media in dual-energy CT might help in visualizing previously undetected uric acid depositions but, with too strong enhancement, obscure gouty tophi. KEY POINTS: • Iodine significantly influences the uric acid crystal detection in systematic phantom studies. • Lower iodine concentrations improved detection of low and medium uric acid concentrations. • High concentrations of iodine hampered detection of all uric acid concentrations.


Assuntos
Artrite Gotosa , Iodo , Humanos , Ácido Úrico/análise , Meios de Contraste , Tomografia Computadorizada por Raios X/métodos
9.
Eur Radiol Exp ; 7(1): 46, 2023 07 31.
Artigo em Inglês | MEDLINE | ID: mdl-37524994

RESUMO

BACKGROUND: Artifacts caused by metal implants are challenging when undertaking computed tomography (CT). Dedicated algorithms have shown promising results although with limitations. Tin filtration (Sn) in combination with high tube voltage also shows promise but with limitations. There is a need to examine these limitations in more detail. The purpose of this study was to investigate the impact of different metal artefact reduction (MAR) algorithms, tin filtration, and ultra-high-resolution (UHR) scanning, alone or in different combinations in both phantom and clinical settings. METHODS: An ethically approved clinical and phantom study was conducted. A modified Catphan® phantom with titanium and stainless-steel inserts was scanned with six different MAR protocols with tube voltage ranging from 80 to 150 kVp. Other scan parameters were kept identical. The differences (∆) in mean HU and standard deviation (SD) in images, with and without metal, were measured and compared. In the clinical study, three independent readers performed visual image quality assessments on eight different protocols using retrospectively acquired images. RESULTS: Iterative MAR had the lowest ∆HU and ∆SD in the phantom study. For images of the forearm, the soft tissue noise for Sn-based 150-kVp UHR protocol with was significantly higher (p = 0.037) than for single-energy MAR protocols. All Sn-based 150-kVp protocols were rated significantly higher (p < 0.046 than the single-energy MAR protocols in the visual assessment. CONCLUSIONS: All Sn-based 150-kVp UHR protocols showed similar objective MAR in the phantom study, and higher objective MAR and significantly improved visual image quality than single-energy MAR. RELEVANCE STATEMENT: Images with less metal artifacts and higher visual image quality may be more clinically optimal in CT examination of musculoskeletal patients with metal implants. KEY POINTS: • Metal artifact reduction algorithms and Sn filter combined with high kVp reduce artifacts. • Metal artifact reduction algorithms introduce new artifacts in certain metals. • Sn-based protocols alone may be considered as low metal artifact protocols.


Assuntos
Artefatos , Estanho , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Metais
10.
Eur Radiol Exp ; 7(1): 34, 2023 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-37394534

RESUMO

Flow-related artifacts have been observed in highly accelerated T1-weighted contrast-enhanced wave-controlled aliasing in parallel imaging (CAIPI) magnetization-prepared rapid gradient-echo (MPRAGE) imaging and can lead to diagnostic uncertainty. We developed an optimized flow-mitigated Wave-CAIPI MPRAGE acquisition protocol to reduce these artifacts through testing in a custom-built flow phantom. In the phantom experiment, maximal flow artifact reduction was achieved with the combination of flow compensation gradients and radial reordered k-space acquisition and was included in the optimized sequence. Clinical evaluation of the optimized MPRAGE sequence was performed in 64 adult patients, who all underwent contrast-enhanced Wave-CAIPI MPRAGE imaging without flow-compensation and with optimized flow-compensation parameters. All images were evaluated for the presence of flow-related artifacts, signal-to-noise ratio (SNR), gray-white matter contrast, enhancing lesion contrast, and image sharpness on a 3-point Likert scale. In the 64 cases, the optimized flow mitigation protocol reduced flow-related artifacts in 89% and 94% of the cases for raters 1 and 2, respectively. SNR, gray-white matter contrast, enhancing lesion contrast, and image sharpness were rated as equivalent for standard and flow-mitigated Wave-CAIPI MPRAGE in all subjects. The optimized flow mitigation protocol successfully reduced the presence of flow-related artifacts in the majority of cases.Relevance statementAs accelerated MRI using novel encoding schemes become increasingly adopted in clinical practice, our work highlights the need to recognize and develop strategies to minimize the presence of unexpected artifacts and reduction in image quality as potential compromises to achieving short scan times.Key points• Flow-mitigation technique led to an 89-94% decrease in flow-related artifacts.• Image quality, signal-to-noise ratio, enhancing lesion conspicuity, and image sharpness were preserved with the flow mitigation technique.• Flow mitigation reduced diagnostic uncertainty in cases where flow-related artifacts mimicked enhancing lesions.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Adulto , Humanos , Imageamento por Ressonância Magnética/métodos , Razão Sinal-Ruído , Imagens de Fantasmas , Artefatos
11.
Eur Radiol Exp ; 7(1): 25, 2023 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-37211577

RESUMO

PURPOSE: To develop an isotropic three-dimensional (3D) T2 mapping technique for the quantitative assessment of the composition of knee cartilage with high accuracy and precision. METHODS: A T2-prepared water-selective isotropic 3D gradient-echo pulse sequence was used to generate four images at 3 T. These were used for three T2 map reconstructions: standard images with an analytical T2 fit (AnT2Fit); standard images with a dictionary-based T2 fit (DictT2Fit); and patch-based-denoised images with a dictionary-based T2 fit (DenDictT2Fit). The accuracy of the three techniques was first optimized in a phantom study against spin-echo imaging, after which knee cartilage T2 values and coefficients of variation (CoV) were assessed in ten subjects in order to establish accuracy and precision in vivo. Data given as mean ± standard deviation. RESULTS: After optimization in the phantom, whole-knee cartilage T2 values of the healthy volunteers were 26.6 ± 1.6 ms (AnT2Fit), 42.8 ± 1.8 ms (DictT2Fit, p < 0.001 versus AnT2Fit), and 40.4 ± 1.7 ms (DenDictT2Fit, p = 0.009 versus DictT2Fit). The whole-knee T2 CoV reduced from 51.5% ± 5.6% to 30.5 ± 2.4 and finally to 13.1 ± 1.3%, respectively (p < 0.001 between all). The DictT2Fit improved the data reconstruction time: 48.7 ± 11.3 min (AnT2Fit) versus 7.3 ± 0.7 min (DictT2Fit, p < 0.001). Very small focal lesions were observed in maps generated with DenDictT2Fit. CONCLUSIONS: Improved accuracy and precision for isotropic 3D T2 mapping of knee cartilage were demonstrated by using patch-based image denoising and dictionary-based reconstruction. KEY POINTS: • Dictionary T2 fitting improves the accuracy of three-dimensional (3D) knee T2 mapping. • Patch-based denoising results in high precision in 3D knee T2 mapping. • Isotropic 3D knee T2 mapping enables the visualization of small anatomical details.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Voluntários Saudáveis
12.
Eur Radiol Exp ; 7(1): 23, 2023 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-37097376

RESUMO

BACKGROUND: In this study, stent appearance in a novel silicon-based photon-counting computed tomography (Si-PCCT) prototype was compared with a conventional energy-integrating detector CT (EIDCT) system. METHODS: An ex vivo phantom was created, consisting of a 2% agar-water mixture, in which human-resected and stented arteries were individually embedded. Using similar technique parameters, helical scan data was acquired using a novel prototype Si-PCCT and a conventional EIDCT system at a volumetric CT dose index (CTDIvol) of 9 mGy. Reconstructions were made at 502 and 1502 mm2 field-of-views (FOVs) using a bone kernel and adaptive statistical iterative reconstruction with 0% blending. Using a 5-point Likert scale, reader evaluations were performed on stent appearance, blooming and inter-stent visibility. Quantitative image analysis was performed on stent diameter accuracy, blooming and inter-stent distinction. Qualitative and quantitative differences between Si-PCCT and EIDCT systems were tested with a Wilcoxon signed-rank test and a paired samples t-test, respectively. Inter- and intra-reader agreement was assessed using the intraclass correlation coefficient (ICC). RESULTS: Qualitatively, Si-PCCT images were rated higher than EIDCT images at 150-mm FOV, based on stent appearance (p = 0.026) and blooming (p = 0.015), with a moderate inter- (ICC = 0.50) and intra-reader (ICC = 0.60) agreement. Quantitatively, Si-PCCT yielded more accurate diameter measurements (p = 0.001), reduced blooming (p < 0.001) and improved inter-stent distinction (p < 0.001). Similar trends were observed for the images reconstructed at 50-mm FOV. CONCLUSIONS: When compared to EIDCT, the improved spatial resolution of Si-PCCT yields enhanced stent appearance, more accurate diameter measurements, reduced blooming and improved inter-stent distinction. KEY POINTS: • This study evaluated stent appearance in a novel silicon-based photon-counting computed tomography (Si-PCCT) prototype. • Compared to standard CT, Si-PCCT resulted in more accurate stent diameter measurements. • Si-PCCT also reduced blooming artefacts and improved inter-stent visibility.


Assuntos
Fótons , Silício , Humanos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Stents
13.
Eur Radiol Exp ; 7(1): 1, 2023 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-36617620

RESUMO

BACKGROUND: To assess the impact of the new version of a deep learning (DL) spectral reconstruction on image quality of virtual monoenergetic images (VMIs) for contrast-enhanced abdominal computed tomography in the rapid kV-switching platform. METHODS: Two phantoms were scanned with a rapid kV-switching CT using abdomen-pelvic CT examination parameters at dose of 12.6 mGy. Images were reconstructed using two versions of DL spectral reconstruction algorithms (DLSR V1 and V2) for three reconstruction levels. The noise power spectrum (NSP) and task-based transfer function at 50% (TTF50) were computed at 40/50/60/70 keV. A detectability index (d') was calculated for enhanced lesions at low iodine concentrations: 2, 1, and 0.5 mg/mL. RESULTS: The noise magnitude was significantly lower with DLSR V2 compared to DLSR V1 for energy levels between 40 and 60 keV by -36.5% ± 1.4% (mean ± standard deviation) for the standard level. The average NPS frequencies increased significantly with DLSR V2 by 23.7% ± 4.2% for the standard level. The highest difference in TTF50 was observed at the mild level with a significant increase of 61.7% ± 11.8% over 40-60 keV energy with DLSR V2. The d' values were significantly higher for DLSR V2 versus DLSR V1. CONCLUSIONS: The DLSR V2 improves image quality and detectability of low iodine concentrations in VMIs compared to DLSR V1. This suggests a great potential of DLSR V2 to reduce iodined contrast doses.


Assuntos
Aprendizado Profundo , Iodo , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Processamento de Imagem Assistida por Computador/métodos
14.
Eur Radiol ; 33(3): 1629-1640, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36323984

RESUMO

OBJECTIVES: To compare the image quality and hepatic metastasis detection of low-dose deep learning image reconstruction (DLIR) with full-dose filtered back projection (FBP)/iterative reconstruction (IR). METHODS: A contrast-detail phantom consisting of low-contrast objects was scanned at five CT dose index levels (10, 6, 3, 2, and 1 mGy). A total of 154 participants with 305 hepatic lesions who underwent abdominal CT were enrolled in a prospective non-inferiority trial with a three-arm design based on phantom results. Data sets with full dosage (13.6 mGy) and low dosages (9.5, 6.8, or 4.1 mGy) were acquired from two consecutive portal venous acquisitions, respectively. All images were reconstructed with FBP (reference), IR (control), and DLIR (test). Eleven readers evaluated phantom data sets for object detectability using a two-alternative forced-choice approach. Non-inferiority analyses were performed to interpret the differences in image quality and metastasis detection of low-dose DLIR relative to full-dose FBP/IR. RESULTS: The phantom experiment showed the dose reduction potential from DLIR was up to 57% based on the reference FBP dose index. Radiation decreases of 30% and 50% resulted in non-inferior image quality and hepatic metastasis detection with DLIR compared to full-dose FBP/IR. Radiation reduction of 70% by DLIR performed inferiorly in detecting small metastases (< 1 cm) compared to full-dose FBP (difference: -0.112; 95% confidence interval [CI]: -0.178 to 0.047) and full-dose IR (difference: -0.123; 95% CI: -0.182 to 0.053) (p < 0.001). CONCLUSION: DLIR enables a 50% dose reduction for detecting low-contrast hepatic metastases while maintaining comparable image quality to full-dose FBP and IR. KEY POINTS: • Non-inferiority study showed that deep learning image reconstruction (DLIR) can reduce the dose to oncological patients with low-contrast lesions without compromising the diagnostic information. • Radiation dose levels for DLIR can be reduced to 50% of full-dose FBP and IR for detecting low-contrast hepatic metastases, while maintaining comparable image quality. • The reduction of radiation by 70% by DLIR is clinically acceptable but insufficient for detecting small low-contrast hepatic metastases (< 1 cm).


Assuntos
Aprendizado Profundo , Neoplasias Hepáticas , Humanos , Algoritmos , Processamento de Imagem Assistida por Computador , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Imagens de Fantasmas , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos
15.
Imaging Sci Dent ; 53(4): 345-353, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38174032

RESUMO

Purpose: The objective of this study was to propose a method for developing a clinical phantom to reproduce various diseases that are clinically prevalent in the field of dentistry. This could facilitate diverse clinical research without unnecessarily exposing patients to radiation. Material and Methods: This study utilized a single dry skull, which was visually and radiographically examined to evaluate its condition. Existing lesions on the dry skull were preserved, and other relevant lesions were artificially created as necessary. These lesions were then documented using intraoral radiography and cone-beam computed tomography. Once all pre-existing and reproduced lesions were confirmed by the consensus of 2 oral and maxillofacial radiologists, the skull was embedded in a soft tissue substitute. To validate the process, cone-beam computed tomography scans and panoramic radiographs were obtained of the fabricated phantom. All acquired images were subsequently evaluated. Results: Most lesions could be identified on panoramic radiographs, although some sialoliths and cracked teeth were confirmed only through cone-beam computed tomographic images. A small gap was observed between the epoxy resin and the bone structures. However, 2 oral and maxillofacial radiologists agreed that this space did not meaningfully impact the interpretation process. Conclusion: The newly developed phantom has potential for use as a standardized phantom within the dental field. It may be utilized for a variety of imaging studies, not only for optimization purposes, but also for addressing other experimental issues related to both 2- and 3-dimensional diagnostic radiography.

16.
Eur Radiol Exp ; 6(1): 55, 2022 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-36411379

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) can be used to target tumour components in biopsy procedures, while the ability to precisely correlate histology and MRI signal is crucial for imaging biomarker validation. Robotic MRI/computed tomography (CT) fusion biopsy offers the potential for this without in-gantry biopsy, although requires development. METHODS: Test-retest T1 and T2 relaxation times, attenuation (Hounsfield units, HU), and biopsy core quality were prospectively assessed (January-December 2021) in a range of gelatin, agar, and mixed gelatin/agar solutions of differing concentrations on days 1 and 8 after manufacture. Suitable materials were chosen, and four biopsy phantoms were constructed with twelve spherical 1-3-cm diameter targets visible on MRI, but not on CT. A technical pipeline was developed, and intraoperator and interoperator reliability was tested in four operators performing a total of 96 biopsies. Statistical analysis included T1, T2, and HU repeatability using Bland-Altman analysis, Dice similarity coefficient (DSC), and intraoperator and interoperator reliability. RESULTS: T1, T2, and HU repeatability had 95% limits-of-agreement of 8.3%, 3.4%, and 17.9%, respectively. The phantom was highly reproducible, with DSC of 0.93 versus 0.92 for scanning the same or two different phantoms, respectively. Hit rate was 100% (96/96 targets), and all operators performed robotic biopsies using a single volumetric acquisition. The fastest procedure time was 32 min for all 12 targets. CONCLUSIONS: A reproducible biopsy phantom was developed, validated, and used to test robotic MRI/CT-fusion biopsy. The technique was highly accurate, reliable, and achievable in clinically acceptable timescales meaning it is suitable for clinical application.


Assuntos
Gelatina , Procedimentos Cirúrgicos Robóticos , Reprodutibilidade dos Testes , Ágar , Biópsia Guiada por Imagem , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos
17.
Eur Radiol ; 32(12): 8122-8130, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35771246

RESUMO

OBJECTIVES: To investigate the effect of the phantom-based correction method for standardizing myocardial native T1 and extracellular volume fraction (ECV) in healthy subjects. METHODS: Seventy-one healthy asymptomatic adult (≥ 20 years) volunteers of five different age groups (34 men and 37 women, 45.5 ± 15.5 years) were prospectively enrolled in three academic hospitals. Cardiac MRI including Modified Look - Locker Inversion recovery T1 mapping sequence was performed using a 3-Tesla system with a different type of scanner for each hospital. Native T1 and ECV were measured in the short-axis T1 map and analyzed for mean values of the 16 entire segments. The myocardial T1 value of each subject was corrected based on the site-specific equation derived from the T1 Mapping and ECV Standardization phantom. The global native T1 and ECV were compared between institutions before and after phantom-based correction, and the variation in native T1 and ECV among institutions was assessed using a coefficient of variation (CoV). RESULTS: The global native T1 value significantly differed between the institutions (1198.7 ± 32.1 ms, institution A; 1217.7 ± 39.9 ms, institution B; 1232.7 ± 31.1 ms, institution C; p = 0.002), but the mean ECV did not (26.6-27.5%, p = 0.355). After phantom-based correction, the global native T1 and ECV were 1289.7 ± 32.4 ms and 25.0 ± 2.7%, respectively, and CoV for native T1 between the three institutions decreased from 3.0 to 2.5%. The corrected native T1 value did not significantly differ between institutions (1284.5 ± 31.5 ms, institution A; 1296.5 ± 39.1 ms, institution B; 1291.3 ± 29.3 ms, institution C; p = 0.440), and neither did the ECV (24.4-25.9%, p = 0.078). CONCLUSIONS: The phantom-based correction method can provide standardized reference T1 values in healthy subjects. KEY POINTS: • After phantom-based correction, the global native T1 of 16 entire myocardial segments on 3-T cardiac MRI is 1289.4 ± 32.4 ms, and the extracellular volume fraction was 25.0 ± 2.7% for healthy subjects. • After phantom - based correction was applied, the differences in the global native T1 among institutions became insignificant, and the CoV also decreased from 3.0 to 2.5%.


Assuntos
Imageamento por Ressonância Magnética , Miocárdio , Adulto , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Voluntários Saudáveis , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Miocárdio/patologia , Imageamento por Ressonância Magnética/métodos , Padrões de Referência , Imagem Cinética por Ressonância Magnética , Meios de Contraste
18.
Eur Radiol ; 32(7): 4587-4595, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35174400

RESUMO

OBJECTIVES: To compare image quality of deep learning reconstruction (AiCE) for radiomics feature extraction with filtered back projection (FBP), hybrid iterative reconstruction (AIDR 3D), and model-based iterative reconstruction (FIRST). METHODS: Effects of image reconstruction on radiomics features were investigated using a phantom that realistically mimicked a 65-year-old patient's abdomen with hepatic metastases. The phantom was scanned at 18 doses from 0.2 to 4 mGy, with 20 repeated scans per dose. Images were reconstructed with FBP, AIDR 3D, FIRST, and AiCE. Ninety-three radiomics features were extracted from 24 regions of interest, which were evenly distributed across three tissue classes: normal liver, metastatic core, and metastatic rim. Features were analyzed in terms of their consistent characterization of tissues within the same image (intraclass correlation coefficient ≥ 0.75), discriminative power (Kruskal-Wallis test p value < 0.05), and repeatability (overall concordance correlation coefficient ≥ 0.75). RESULTS: The median fraction of consistent features across all doses was 6%, 8%, 6%, and 22% with FBP, AIDR 3D, FIRST, and AiCE, respectively. Adequate discriminative power was achieved by 48%, 82%, 84%, and 92% of features, and 52%, 20%, 17%, and 39% of features were repeatable, respectively. Only 5% of features combined consistency, discriminative power, and repeatability with FBP, AIDR 3D, and FIRST versus 13% with AiCE at doses above 1 mGy and 17% at doses ≥ 3 mGy. AiCE was the only reconstruction technique that enabled extraction of higher-order features. CONCLUSIONS: AiCE more than doubled the yield of radiomics features at doses typically used clinically. Inconsistent tissue characterization within CT images contributes significantly to the poor stability of radiomics features. KEY POINTS: • Image quality of CT images reconstructed with filtered back projection and iterative methods is inadequate for the majority of radiomics features due to inconsistent tissue characterization, low discriminative power, or low repeatability. • Deep learning reconstruction enhances image quality for radiomics and more than doubled the feature yield at doses that are typically used in clinical CT imaging. • Image reconstruction algorithms can optimize image quality for more reliable quantification of tissues in CT images.


Assuntos
Aprendizado Profundo , Abdome , Idoso , Algoritmos , Humanos , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos
19.
Quant Imaging Med Surg ; 12(1): 726-741, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34993114

RESUMO

BACKGROUND: To compare task-based image quality (TB-IQ) among virtual monoenergetic images (VMI) and linear-blended images (LBI) from dual-energy CT as a function of contrast task, radiation dose, size, and lesion diameter. METHODS: A TB-IQ phantom (Mercury Phantom 4.0, Sun Nuclear Corporation) was imaged on a third-generation dual-source dual-energy CT with 100/Sn150 kVp at three volume CT dose levels (5, 10, 15 mGy). Three size sections (diameters 16, 26, 36 cm) with subsections for image noise and spatial resolution analysis were used. High-contrast tasks (e.g., calcium-containing stone and vascular lesion) were emulated using bone and iodine inserts. A low-contrast task (e.g., low-contrast lesion or hematoma) was emulated using a polystyrene insert. VMI at 40-190 keV and LBI were reconstructed. Noise power spectrum (NPS) determined the noise magnitude and texture. Spatial resolution was assessed using the task-transfer function (TTF) of the three inserts. The detectability index (d') served as TB-IQ metric. RESULTS: Noise magnitude increased with increasing phantom size, decreasing dose, and decreasing VMI-energy. Overall, noise magnitude was higher for VMI at 40-60 keV compared to LBI (range of noise increase, 3-124%). Blotchier noise texture was found for low and high VMIs (40-60 keV, 130-190 keV) compared to LBI. No difference in spatial resolution was observed for high contrast tasks. d' increased with increasing dose level or lesion diameter and decreasing size. For high-contrast tasks, d' was higher at 40-80 keV and lower at high VMIs. For the low-contrast task, d' was higher for VMI at 70-90 keV and lower at 40-60 keV. CONCLUSIONS: Task-based image quality differed among VMI-energy and LBI dependent on the contrast task, dose level, phantom size, and lesion diameter. Image quality could be optimized by tailoring VMI-energy to the contrast task. Considering the clinical relevance of iodine, VMIs at 50-60 keV could be proposed as an alternative to LBI.

20.
Front Dent ; 19: 32, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36865948

RESUMO

Objectives: 'Field of view (FOV) size' affects the quality of radiographic images and the radiation dose received by patients. In cone-beam computed tomography (CBCT) FOV should be selected according to therapeutic purposes. While aiming for the highest diagnostic image quality, the radiation dose should be kept to a minimum to reduce the risk for patients. The purpose of this study was to assess the effect of different sizes of FOV on contrast-to-noise ratio (CNR) in five different CBCT units. Materials and Methods: In this experimental study, CBCT scans were taken from a dried human mandible containing a resin block fixed to the lingual cortex and a resin ring was used to simulate soft tissue during scans. Five CBCT units including, NewTom VGi, NewTom GiANO, Soredex SCANORA 3D, Planmeca ProMax, and Asahi Alphard 3030 were evaluated. Each unit had 3 to 5 different FOVs. Images were obtained and analyzed with ImageJ software and CNR was calculated in each image. ANOVA and T-test were used for statistical analysis (P<0.05). Results: Comparison among different FOVs of each unit showed significant CNR reductions in small FOVs (P<0.05). Similar FOV sizes of different CBCT devices were also compared and demonstrated significant differences (P<0.05). Conclusion: A direct relationship between FOV size and CNR was observed in all five CBCT units, but differences in exposure parameters of these units led to variable CNR in FOVs with similar sizes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...