Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
Adv Sci (Weinh) ; : e2403028, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38946620

RESUMO

Superhydrophobic surfaces (SHS) exhibit a pronounced ability to resist wetting. When immersed in water, water does not penetrate between the microstructures of the SHS. Instead, a thin layer of trapped gas remains, i.e., plastron. This fractional wetting is also known as the Cassie-Baxter state (CB). Impairment of superhydrophobicity occurs when water penetrates the plastron and, when complete wetting is achieved, a Wenzel state (W) results. Subsequent recovery back to CB state is one of the main challenges in the field of SHS wetting. Current methods for plastron recovery require complex mechanical or chemical integration, are time-consuming or lack spatial control. Here an on-demand, contact-less approach for performing facile transitions between these wetting states at micrometer length scales is proposed. This is achieved by the use of acoustic radiation force (ARF) produced by high-intensity focused ultrasound (HIFU). Switching from CB to W state takes <100 µs, while the local recovery back to CB state takes <45 s. To the best of authors knowledge, this is the first demonstration of ARF-induced manipulation of the plastron enabling facile two-way controlled switching of wetting states.

2.
Eur J Obstet Gynecol Reprod Biol ; 291: 162-167, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37898047

RESUMO

OBJECTIVE: The aim of the present study was to compare efficacy and safety of the vaginal patch plastron (VPP) associated to the anterior sacrospinous fixation (SSLF-A) with a TVM procedure (Uphold™ LITE support-system) for the treatment of the advanced anterior vaginal wall prolapse. STUDY DESIGN: Single-center retrospective study. Women with symptomatic anterior prolapse ≥ III stage according to the POP-quantification (POP-Q) system and submitted to the VPP associated with the SSLF-A or to the Uphold™ procedure were included. Primary outcome was to compare objective and subjective cystocele relapse and reoperation rate at 6- and 12-month follow-up. Secondary outcome was to describe peri- and postoperative complications. Pearson chi-square test and exact Fisher test were adopted for categorical variables, while intergroup Mann-Whitney U test and intragroup Wilcoxon Rank Sum Test for continuous variables; the statistical analysis was conducted at 95 % confidence level. RESULTS: Fifty-five women in VPP-group and 118 women in Uphold-group were included. At 6-month follow-up, objective anterior relapse in VPP-group (3/55, 5.4 %) was like Uphold-group (5/118, 4.2 %; p = 0.71), as well as objective apical relapse (0/55, 0 % vs 3/118, 2.5 %; p = 0.55); no significant difference emerged in bulge symptoms (1/55, 1.8 % vs 5/118, 4.2 %; p = 0.67). At 12-month follow-up women were telephonically investigated; no significant difference emerged in bulge symptoms (1/55, 1.8 % vs 6/118, 5.1 %; p = 0.43). Reoperation rate for the composite outcome POP relapse, stress urinary incontinence (SUI) and remotion of the TVM resulted lower in the VPP group (1/55, 1.8 % vs 13/118, 11 %; p = 0.03). Post-operative buttock pain (32/55, 58.2 % vs 24/118, 20.3 %; p < 0.0001) and post-operative urinary retention (16/55, 29.1 % vs 6/118, 5.1 %; p < 0.0001) were higher in VPP-group, with a complete resolution between 2 and 3 weeks after treatment. CONCLUSION: VPP associated with SSLF-A was as effective as Uphold™ LITE support-system for both anterior and central compartment prolapse treatment at 6- and 12-month follow-up. VPP-group presented a lower reoperation rate for the composite outcome prolapse relapse repair, SUI, and removal of the mesh.


Assuntos
Cistocele , Prolapso de Órgão Pélvico , Incontinência Urinária por Estresse , Prolapso Uterino , Feminino , Humanos , Prolapso de Órgão Pélvico/cirurgia , Estudos Retrospectivos , Prolapso Uterino/cirurgia , Prolapso Uterino/complicações , Cistocele/cirurgia , Incontinência Urinária por Estresse/etiologia , Complicações Pós-Operatórias/etiologia , Recidiva , Resultado do Tratamento , Telas Cirúrgicas/efeitos adversos , Procedimentos Cirúrgicos em Ginecologia/efeitos adversos , Procedimentos Cirúrgicos em Ginecologia/métodos
3.
Rev. argent. coloproctología ; 34(3): 22-26, sept. 2023. ilus
Artigo em Espanhol | LILACS | ID: biblio-1552478

RESUMO

Un plastrón apendicular es una masa apendicular palpable que contiene el apéndice inflamado, vísceras adyacentes y el omento mayor, asociado a o no a la presencia de pus. El manejo del plastrón apendicular abscedado es controvertido. Cuando hay signos de sepsis asociados, la indicación es una intervención quirúrgica de urgencia, de lo contrario puede optarse por un tratamiento conservador. La utilización de drenaje percutáneo tiene una alta tasa de efectividad, aunque la tasa de neoplasias no detectadas presenta un porcentaje no despreciable, especialmente en los pacientes mayores de 40 años. El objetivo de esta presentación es comunicar una paciente de 65 años con diagnóstico presuntivo de plastrón apendicular abscedado quien luego del fracaso de los drenajes percutáneos fue sometida a una laparotomía exploratoria y hemicolectomía derecha. El diagnóstico histopatológico fue de adenocarcinoma mucinoso del apéndice. (AU)


A palpable inflammatory appendiceal mass may contain the inflamed appendix, adjacent viscera, and the greater omentum, associated or not with the presence of pus. The management of an inflammatory appendiceal mass is controversial. When there are associated signs of sepsis, the indication is emergency surgery, otherwise, you can opt for a conservative treatment. The use of percutaneous drainage has a high rate of effectiveness, although the rate of undetected neoplasia is not negligible, especially in patients older than 40 years. We present the case of a 65-year-old female patient with a presumptive diagnosis of an appendiceal mass with abscess, who underwent exploratory laparotomy and right hemicolectomy after percutaneous drainage failure. The histopathological diagnosis was mucinous adenocarcinoma of the appendix. (AU)


Assuntos
Humanos , Feminino , Idoso , Neoplasias do Apêndice/patologia , Apendicite/cirurgia , Apendicite/diagnóstico , Apendicectomia , Diagnóstico por Imagem , Colectomia , Adenocarcinoma Mucinoso , Abscesso Abdominal
4.
J Clin Med ; 12(14)2023 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-37510696

RESUMO

Cystoceles are the most common prolapses. Limitation of the use of synthetic mesh has led to the comeback of native tissue repair procedures. We have developed a new transobturator technique with native tissue based on a mix of a vaginal plastron technique and the transobturator procedure. We present the functional and anatomical mid-term results. In this retrospective study, the vaginal plastron technique and the transobturator procedure were performed in 32 patients. Functional assessment with several validated quality-of-life questionnaires (SF-12, PFIQ-7, PFDI-20, PISQ12) and anatomical evaluation with pelvic examination were performed at 1, 6, and 12 months after surgery. The anatomical success rate was 94.4% at 12 months. There was one Clavien-Dindo grade 2 postoperative complication (one urinary tract infection). All of the quality-of-life scores were statistically significantly improved at one year follow-up. The transobturator technique combined with the vaginal plastron seems to be a promising, effective, innovative, and relevant technique for the repair of high-stage cystoceles.

5.
Proc Natl Acad Sci U S A ; 120(3): e2211092120, 2023 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-36634141

RESUMO

Recent experimental and computational investigations have shown that trace amounts of surfactants, unavoidable in practice, can critically impair the drag reduction of superhydrophobic surfaces (SHSs), by inducing Marangoni stresses at the air-liquid interface. However, predictive models for realistic SHS geometries do not yet exist, which has limited the understanding and mitigation of these adverse surfactant effects. To address this issue, we derive a model for laminar, three-dimensional flow over SHS gratings as a function of geometry and soluble surfactant properties, which together encompass 10 dimensionless groups. We establish that the grating length g is the key geometric parameter and predict that the ratio between actual and surfactant-free slip increases with g2. Guided by our model, we perform synergistic numerical simulations and microfluidic experiments, finding good agreement with the theory as we vary surfactant type and SHS geometry. Our model also enables the estimation, based on velocity measurements, of a priori unknown properties of surfactants inherently present in microfluidic systems. For SHSs, we show that surfactant effects can be predicted by a single parameter, representing the ratio between the grating length and the interface length scale beyond which the flow mobilizes the air-water interface. This mobilization length is more sensitive to the surfactant chemistry than to its concentration, such that even trace-level contaminants may significantly increase drag if they are highly surface active. These findings advance the fundamental understanding of realistic interfacial flows and provide practical strategies to maximize superhydrophobic drag reduction.


Assuntos
Surfactantes Pulmonares , Tensoativos , Tensoativos/química , Microfluídica , Lipoproteínas , Interações Hidrofóbicas e Hidrofílicas
6.
J Clin Med ; 11(22)2022 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-36431162

RESUMO

Background: this study aims to compare the efficacy and safety of vaginal patch plastron (VPP) associated to anterior sacrospinous ligament fixation (SSLF-A) with SSLF-A associated or not to the anterior colporrhaphy (AC) for cystocele treatment. Methods: single-center retrospective study in women with cystocele ≥ III stage submitted to surgery. The primary outcome was to compare objective and subjective cystocele relapse and reoperation rate at follow-up > 6 months. The secondary outcome was to describe peri- and postoperative complications and risk factors for cystocele objective relapse. Results: 75 women were submitted to SSLF-A and 61 women to VPP. VPP objective and subjective relapse (6.5%, 4/61 and 1.1%, 1/61) were lower than SSLF-A (26.7%, 20/75 and 20%, 15/75; p = 0.002 and p = 0.001, respectively). SSLF-A had a higher reintervention rate, but not significantly (6.6%, 5/75 vs. 0%, 0/61; p = 0.06). Previous hysterectomy was a risk factor (HR 4; 1.3−12.1) while VPP was protective factor (HR 0.2; 0.1−0.9) for cystocele anatomical relapse. Postoperative buttock pain was more prevalent in VPP (57.4%, 35/75 vs. 34.7%, 26/61; p = 0.01). Conclusions: VPP is effective and safe for advanced cystocele treatment, with lower objective and subjective relapse rates in comparison to isolated SSLF-A or associated with the AC.

7.
ACS Appl Mater Interfaces ; 14(46): 52524-52534, 2022 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-36373889

RESUMO

Air plastrons trapped on the surfaces of underwater superhydrophobic surfaces are critical for their function. Fibrillar morphologies offer a natural pathway, yet they are limited to a narrow range of liquid-surface systems and are vulnerable to pressure fluctuations that irreversibly destroy the air layer plastron. Inspired by the convexly grooved bases of water fern (Salvinia) leaves that support their fibrous outgrowths, we focus on the effect of such second-level grooved structures or microgrooves on the plastron restoration on immersed three-dimensional (3D)-printed hierarchical surfaces. Elliptical, interconnected microgrooves are fabricated with varying surface curvatures to study the effect of their morphology. Immersion experiments reveal that the convex groove curvature stabilizes a seed gas layer (SGL) that facilitates plastron restoration for all immersed hydrophobic surfaces. Theoretical calculations and atomic-scale computations reveal that the SGL storage capacity that sets the SGL robustness follows from the liquid menisci adaption to the groove geometry and pressure, from micro- to nanoscales, and it can be further tuned using separated grooves. Our study highlights groove convexity as a key morphological feature for the design of second-level architectures for underwater air plastron restoration on hierarchical superhydrophobic surfaces.

8.
J Minim Invasive Gynecol ; 29(6): 705-706, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35314372

RESUMO

STUDY OBJECTIVE: To demonstrate the feasibility of transvaginal natural orifice transluminal endoscopic surgery (vNOTES) meshless anterior repair for the treatment of pelvic organ prolapse (POP). DESIGN: Stepwise demonstration of the technique with narrated video footage. SETTING: The vNOTES approach is a recent and rapidly developing technique that allows safe endoscopic transvaginal treatment of benign uterine pathologies [1]. Its use in the treatment of POP is still in its early stages; however, the first results are encouraging in terms of anatomy, functionality, and safety [2]. INTERVENTIONS: We describe the vNOTES technique of meshless anterior POP repair using a vaginal plastron [3]. The "vaginal plastron" technique uses an autologous vaginal strip that is left attached to the bladder and suspended from the arcus tendineus. After the delimitation of a 6 cm square vaginal strip, a lateral dissection is performed on each side between the bladder and the vaginal fascia to enter the paravesical space. The vaginal strip is left attached to the bladder wall and will later be fixed laterally to the arcus tendineus with 6 nonabsorbable monofilament sutures, caliber 0 (3 on each side of the plastron). The fixation points on the arcus tendineus concern the internal obturator fascia ventrally and the iliococcygeus fascia dorsally. The sutures are placed under endoscopic view using a transvaginal access platform (GelPOINT V-Path, Applied Medical, Rancho Santa Margarita, CA). After deflation and removal of the platform, the sutures are attached to the vaginal strip. Once the vaginal plastron is secured, the anterior vaginal wall is closed. CONCLUSION: The vNOTES approach offers an endoscopic anatomic view of the paravesical space, thus reducing any blind surgical procedure. It provides an alternative route in the performance of meshless anterior POP repair.


Assuntos
Cirurgia Endoscópica por Orifício Natural , Prolapso de Órgão Pélvico , Colpotomia , Feminino , Humanos , Cirurgia Endoscópica por Orifício Natural/métodos , Prolapso de Órgão Pélvico/cirurgia , Gravidez , Útero/cirurgia , Vagina/cirurgia
9.
J Gynecol Obstet Hum Reprod ; 51(1): 102234, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34571197

RESUMO

Native tissue cystocele repair has been the cornerstone of prolapse surgery, especially since the learned societies warned clinicians and patients about serious mesh related complications and recommend a vaginal route without prosthesis in first intention. Surgical techniques mainly consist in anterior colporraphy, vaginal patch plastron and para vaginal repair. However, in case of vaginal patch plastron, the vagina left in contact with the bladder is a material of much better quality than colporraphy alone. The multiplication of native tissues, generating post-operative fibrosis, associated with anchorage on a strong ligamentous structure, allows to expect better outcomes compared to anterior colporraphy. Indeed, vaginal plastron corrects median cystoceles with a vaginal strip as well as lateral cystoceles thanks to bilateral paravaginal suspension. Thereby, vaginal patch plastron appears to be a good compromise between the 3 autologous techniques with median and paralateral repair We aimed to describe the surgical technique of the vaginal patch plastron for vaginal native tissue repair for cystocele.


Assuntos
Cistocele/cirurgia , Implantação de Prótese/instrumentação , Telas Cirúrgicas/normas , Adulto , Cistocele/complicações , Feminino , Humanos , Pessoa de Meia-Idade , Prolapso de Órgão Pélvico/cirurgia , Implantação de Prótese/métodos , Implantação de Prótese/tendências
10.
ACS Appl Mater Interfaces ; 13(48): 58096-58103, 2021 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-34813281

RESUMO

Protein fouling on critical biointerfaces causes significant public health and clinical ramifications. Multiple strategies, including superhydrophobic (SHP) surfaces and coatings, have been explored to mitigate protein adsorption on solid surfaces. SHP materials with underwater air plastron (AP) layers hold great promise by physically reducing the contact area between a substrate and protein molecules. However, sustaining AP stability or lifetime is crucial in determining the durability and long-term applications of SHP materials. This work investigated the effect of protein on the AP stability using model SHP substrates, which were prepared from a mixture of silica nanoparticles and epoxy. The AP stability was determined using a submersion test with real-time visualization. The results showed that AP stability was significantly weakened by protein solutions compared to water, which could be attributed to the surface tension of protein solutions and protein adsorption on SHP substrates. The results were further examined to reveal the correlation between protein fouling and accelerated AP dissipation on SHP materials by confocal fluorescent imaging, surface energy measurement, and surface robustness modeling of the Cassie-Baxter to Wenzel transition. The study reveals fundamental protein adsorption mechanisms on SHP materials, which could guide future SHP material design to better mitigate protein fouling on critical biointerfaces.


Assuntos
Materiais Biomiméticos/química , Proteínas/química , Adsorção , Ar , Compostos de Epóxi/química , Interações Hidrofóbicas e Hidrofílicas , Teste de Materiais , Nanopartículas/química , Tamanho da Partícula , Dióxido de Silício/química , Propriedades de Superfície
11.
J Exp Biol ; 224(20)2021 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-34581416

RESUMO

Many insects can climb smooth surfaces using hairy adhesive pads on their legs, mediated by tarsal fluid secretions. It was previously shown that a terrestrial beetle can even adhere and walk underwater. The naturally hydrophobic hairs trap an air bubble around the pads, allowing the hairs to make contact with the substrate as in air. However, it remained unclear to what extent such an air bubble is necessary for underwater adhesion. To investigate the role of the bubble, we measured the adhesive forces in individual legs of live but constrained ladybird beetles underwater in the presence and absence of a trapped bubble and compared these with its adhesion in air. Our experiments revealed that on a hydrophobic substrate, even without a bubble, the pads show adhesion comparable to that in air. On a hydrophilic substrate, underwater adhesion is significantly reduced, with or without a trapped bubble. We modelled the adhesion of a hairy pad using capillary forces. Coherent with our experiments, the model demonstrates that the wetting properties of the tarsal fluid alone can determine the ladybird beetles' adhesion to smooth surfaces in both air and underwater conditions and that an air bubble is not a prerequisite for their underwater adhesion. This study highlights how such a mediating fluid can serve as a potential strategy to achieve underwater adhesion via capillary forces, which could inspire artificial adhesives for underwater applications.


Assuntos
Adesivos , Besouros , Adesividade , Animais , Interações Hidrofóbicas e Hidrofílicas , Insetos , Molhabilidade
12.
Rev. cuba. cir ; 60(3): e1117, 2021.
Artigo em Espanhol | LILACS, CUMED | ID: biblio-1347393

RESUMO

Introducción: El plastrón apendicular es una tumoración inflamatoria constituida por el apéndice inflamado, vísceras adyacentes y epiplón mayor. Puede contener o no pus (absceso/flemón). Objetivo: Precisar si está indicada la apendicectomía de urgencia o de intervalo en los pacientes con plastrón y/o absceso apendicular sometidos a tratamiento no quirúrgico inicial. Métodos: Se realizó una revisión en las bases de datos bibliográficas Web of Science, PubMed, Medline y Lilacs, mediante el motor de búsqueda Google académico. Se seleccionaron 28 artículos en inglés y español; 20 (71,2 por ciento) correspondieron al quinquenio 2016-20 y el 96,4 por ciento de autores extranjeros. Desarrollo: El estándar actual es el tratamiento no quirúrgico inicial del plastrón y el drenaje percutáneo del absceso. La apendicectomía de intervalo tiene un beneficio mínimo y puede conducir a un aumento de los costos, estancia hospitalaria, antibioticoterapia intravenosa y de la morbilidad. Se debe realizar un seguimiento cuidadoso en enfermos con riesgo de enfermedad inflamatoria intestinal o cáncer de colon, sin importar qué opción se elija (operación de intervalo u observación). Conclusiones: La apendicectomía de urgencia no es recomendable porque el componente inflamatorio la hace técnicamente difícil, puede necesitar una colectomía y aumentar la morbilidad, aunque actualmente, la apendicectomía laparoscópica de urgencia puede ser más rentable y segura. La decisión posterior de la apendicectomía a intervalos sigue siendo discutible. El intervalo recomendado varía entre 6 y 8 semanas, tres y seis meses después de la normalización clínico humoral(AU)


Introduction: Appendiceal plastron is an inflammatory tumor made up of inflamed appendix, adjacent viscera and greater omentum. It may or may not contain pus (abscess/phlegmon). Objective: To specify whether emergency or interval appendectomy is indicated in patients with appendicular abscess and/or plastron who had undergone initial nonsurgical treatment. Methods: A review was carried out in the bibliographic databases Web of Science, PubMed, Medline and Lilacs, using the search engine Google Scholar. Twenty-eight articles were selected, in English and Spanish; twenty (71.2 percent) corresponded to the quinquennium 2016-20, while 96.4 percent were written by foreign authors. Development: The current standard is the initial nonsurgical treatment of the plastron and percutaneous drainage of the abscess. Interval appendectomy has minimal benefits and can lead to increased costs, hospital stay, intravenous antibiotic therapy and morbidity. Patients at risk for inflammatory bowel disease or colon cancer should be carefully followed up, regardless of which option is chosen (interval operation or observation). Conclusions: Emergency appendectomy is not recommended because the inflammatory component makes it technically difficult; it may require colectomy and increase morbidity, although currently, emergency laparoscopic appendectomy may be more profitable and safer. The subsequent decision for interval appendectomy remains debatable. The recommended interval varies from six to eight weeks, three and six months after clinical-humoral normalization(AU)


Assuntos
Humanos , Apendicectomia/métodos , Doenças Inflamatórias Intestinais/epidemiologia , Abscesso/etiologia , Emergências , Bases de Dados Bibliográficas , Colectomia/métodos , Ferramenta de Busca/métodos
13.
Front Pharmacol ; 12: 690256, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34054561

RESUMO

Mitochondrial dysfunction with oxidative damage plays the fundamental roles in the pathogenesis of Alzheimer's disease. In traditional Chinese medicine (TCM) practice, animal tissue-derived gelatins are often used as nootropic agents to treat cognitive deterioration and senile dementia. Tortoise plastron gelatin (TPG) and deer antler gelatin (DAG) are the two most commonly used gelatins for this purpose. This study sought to examine the effects of the two gelatins in preventing neuronal mitochondria from oxidative damage. PC12 cells, a cell line derived from rat pheochromocytoma, exposed to the neurotoxin Aß25-35 served as an in vitro model of Alzheimer's disease. The cells were separately pre-treated with TPG and DAG at various concentrations ranging from 6.26 µg/ml-200 µg/ml, followed by co-incubation with 20 µM Aß25-35 for different duration. Cell viability, mitochondrial membrane potential (MMP) and ultrastructure, intracellular ATP, reactive oxygen species (ROS) and calcium (Ca2+) level, the expression of mitochondrial dynamic proteins and biomarkers of apoptosis were measured. Pretreatment with TPG and DAG reversed the Aß-induced reduction of cell viability in a dose-dependent manner. Both TPG and DAG significantly increased MMP and ATP, alleviated the accumulation of damaged mitochondrial fragments, and normalized the aberrant expression of multiple mitochondrial dynamic proteins of the Aß-exposed cells. Both gelatins also suppressed intracellular ROS overproduction and Ca2+ overload, overexpression of cytochrome c and pro-apoptosis biomarkers induced by the Aß exposure. These results suggest that TPG and DAG may have the anti-dementia potential by preventing neuronal mitochondria from oxidative damage.

14.
Molecules ; 26(9)2021 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-33946767

RESUMO

In recent years, various biomimetic materials capable of forming gaseous plastron on their surfaces have been fabricated and widely used in various disciplines and fields. In particular, on submerged surfaces, gaseous plastron has been widely studied for antifouling applications due to its ecological and economic advantages. Gaseous plastron can be formed on the surfaces of various natural living things, including plants, insects, and animals. Gaseous plastron has shown inherent anti-biofouling properties, which has inspired the development of novel theories and strategies toward resisting biofouling formation on different surfaces. In this review, we focused on the research progress of gaseous plastron and its antifouling applications.


Assuntos
Organismos Aquáticos , Incrustação Biológica , Biomimética , Gases , Antibacterianos/química , Antibacterianos/farmacologia , Fenômenos Bioquímicos , Gases/química , Gases/farmacologia , Interações Hidrofóbicas e Hidrofílicas , Propriedades de Superfície
15.
Curr Biol ; 31(13): 2947-2954.e4, 2021 07 12.
Artigo em Inglês | MEDLINE | ID: mdl-33984265

RESUMO

Air-based respiration limits the use of aquatic environments by ancestrally terrestrial animals. To overcome this challenge, diving arthropods have evolved to respire without resurfacing using air held between their cuticle and surrounding water.1-4 Inspired by natural history observations in Haiti (unpublished data) and Costa Rica,5,6 we conducted experiments documenting routine air-based underwater respiration in several distantly related semi-aquatic Anolis lizard species. Semi-aquatic anoles live along neotropical streams and frequently dive for refuge or food,7-12 remaining underwater for up to 18 min. While submerged, these lizards iteratively expire and re-inspire narial air bubbles-underwater "rebreathing." Rebreathed air is used in respiration, as the partial pressure of oxygen in the bubbles decreases with experimental submersion time in living anoles, but not in mechanical controls. Non-aquatic anoles occasionally rebreathe when submerged but exhibit more rudimentary rebreathing behaviors. Anole rebreathing is facilitated by a thin air layer (i.e., a "plastron," sensu Brocher13) supported by the animal's rugose skin upon submergence. We suggest that hydrophobic skin, which we observed in all sampled anoles,14,15 may have been exaptative, facilitating the repeated evolution of specialized rebreathing in species that regularly dive. Phylogenetic analyses strongly suggest that specialized rebreathing is adaptive for semi-aquatic habitat specialists. Air-based rebreathing may enhance dive performance by incorporating dead space air from the buccal cavity or plastron into the lungs, facilitating clearance of carbon dioxide, or allowing uptake of oxygen from surrounding water (i.e., a "physical gill" mechanism4,16).


Assuntos
Evolução Biológica , Mergulho , Lagartos/fisiologia , Respiração , Ar , Animais , Oxigênio , Filogenia , Água
16.
Animals (Basel) ; 11(1)2021 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-33435316

RESUMO

Testudines show phenotypic plasticity, and variation among specific populations within a species is widespread. Morphological differences between populations may reflect ecological factors that drive adaptation to local conditions. In this context, we gathered basic data on the morphology of the Hermann's tortoise (Testudo hermanni boettgeri Mojsisovits, 1889) to document their variation across different geographical regions. We surveyed Hermann's tortoises in five different locales within Albania during April and May 2020 and measured 20 morphological characteristics, including carapace and plastron dimensions. We measured 188 tortoises (81 males, 107 females) in this study, and females were larger (p = 0.0001) and heavier (p = 0.0001) than males. Mean straight carapace length (SCL) and body mass were 172.4 mm and 1128.8 g, respectively, for females, and 151.3 mm and 735 g, respectively, for males. The Albanian T. h. boettgeri were regionally diverged into three different populations that were situated in northern (Shkodra), central (Tirana, Berati, and Ballshi), and southern (Saranda) Albania. The body size (curved carapace length (CCL)) of females was positively correlated (r = 0.216; p = 0.025) with the latitude, in accordance with Bergmann's rule. However, there was no correlation between body size and latitude in males. These striking regional differences among Albanian T. h. boettgeri strongly suggest that further study of molecular variations and reproductive output of Hermann's tortoises is warranted.

17.
Trials ; 21(1): 624, 2020 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-32641096

RESUMO

BACKGROUND: Native tissue cystocele repair has been the cornerstone of prolapse surgery, especially since the learned societies warned clinicians and patients about serious mesh-related complications. Surgical techniques mainly consist in anterior colporraphy and vaginal patch plastron. However, success rates of native tissue cystocele repair are heterogeneous, depending on the design of studies and definition of outcomes. To date, high-quality data comparing vaginal native tissue procedures are still lacking. METHODS: Herein we aimed to describe the design of the first randomized controlled trial (TAPP) comparing anterior colporraphy (plication of the muscularis and adventitial layers of the vaginal wall) and vaginal patch plastron (bladder support anchored on the tendinous arch of the pelvic fascia by lateral sutures) techniques. Our aim is to assess the effectiveness of vaginal native tissue repair at 1 year for cystocele with a combined definition of success-anatomic and functional. The primary endpoint will be the success rate 1 year after surgery with a composite of objective and subjective measures (Aa and Ba points < 0 from POP-Q (Pelvic Organ Prolapse Quantification System) and a negative answer to question 3 of Pelvic Floor Distress Inventory and no need for additional treatment). DISCUSSION: A prospective study has found a success rate at 35% for anterior colporraphy based on a combined definition, both anatomic and functional, as recently recommended. However, the definition of anatomic was strict (POP-Q< 2), while it seems that the best definition of anatomic success is "no prolapse among the hymen", that is to say Aa and Ba points from the POP-Q classification < 0. We hypothesize that vaginal patch plastron will have a better anatomic and functional success comparatively to anterior colporraphy because native tissue is added, as it corrects both median and lateral cystoceles thanks to bilateral paravaginal suspension. TRIAL REGISTRATION: CHU LIMOGES is the sponsor of this research (n°87RI18_0013). This research is supported by the French Department of Health (PHRC 2018-A03476-49) and will be conducted with the support of DGOS (PHRC interregional - GIRCI SOHO). The study protocol was approved by the Human Subjects Protection Review Board (Comité de Protection des Personnes) on May 16, 2019. The trial is registered in the ClinicalTrials.gov registry ( NCT03875989 ).


Assuntos
Diafragma da Pelve/cirurgia , Prolapso de Órgão Pélvico/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Vagina/cirurgia , Feminino , França , Humanos , Estudos Multicêntricos como Assunto , Satisfação do Paciente , Estudos Prospectivos , Desenho de Prótese , Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
18.
J Exp Biol ; 223(Pt 14)2020 07 22.
Artigo em Inglês | MEDLINE | ID: mdl-32527961

RESUMO

The moth Malacosoma castrensis (Lasiocampidae) is commonly found along the Northern Germany coasts, the habitats of which are mainly represented by salt marshes subjected to sea level variations. Surprisingly, terrestrial caterpillars can withstand many hours of being flooded by seawater. The ability to withstand periods of submersion in a terrestrial insect raises the problem of respiration related to avoiding water percolation into the tracheal system. In the present study, we investigated under laboratory conditions the role of water-repellent cuticle structures in oxygen supply in caterpillars of M. castrensis submerged in water. For this purpose, air-layer stability tests using force measurements, and micromorphology of cuticle structures using SEM and fluorescence microscopy, were performed. A plastron appeared when a caterpillar is underwater. The stability, gas composition and internal pressure of the plastron were estimated. The plastron is stabilized by long and scarce hairs, which are much thicker than the corresponding hairs of aquatic insects. Thick and stiff hairs with sclerotized basal and middle regions protrude into the water through the plastron-water interface, while substantial regions of thin and flexible hairs are aligned along the plastron-water interface and their side walls can support pressure in the plastron even below atmospheric pressure. Additional anchoring points between hair's stalk and microtrichia near the hair base provide enhanced stiffness to the hair layer and prevent the hair layer from collapse and water entering between hairs. The advancing contact angle on hairs is more than 90 deg, which is close to the effective contact angle for the whole caterpillar.


Assuntos
Lepidópteros , Manduca , Animais , Alemanha , Insetos , Água
19.
Data Brief ; 29: 105356, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32195296

RESUMO

From 2008 to 2013, we sampled freshwater turtle populations at 66 sites in south, central, and west Texas, USA. Sampling sites included ponds, lakes, resacas (oxbow lakes), canals, and rivers. We sampled turtle populations using baited hoop nets (66 sites) and basking traps (3 sites), and captured turtles by hand opportunistically in terrestrial habitat. We measured carapace length and width, plastron length and width, body depth, and weight of captured turtles. Excluding recaptures, we measured 356 Apalone spinifera emoryi (Texas Spiny Softshell), 24 Chelydra serpentina (Snapping Turtle), 20 Kinosternon flavescens (Yellow Mud Turtle), 47 Trachemys gaigeae (Big Bend Slider), and 1070 Trachemys scripta elegans (Red-eared Slider). Carapace length of Apalone spinifera emoryi ranged from 85 to 426 mm (mean = 182 mm). Carapace length of Chelydra serpentina ranged from 74 to 320 mm (mean = 233 mm). Carapace length of Kinosternon flavescens ranged from 64 to 147 mm (mean = 114 mm). Carapace length of Trachemys gaigeae ranged from 54 to 203 mm (mean = 141 mm). Carapace length of Trachemys scripta elegans ranged from 30 to 328 mm (mean = 171 mm). These data are useful for assessing spatial and temporal variation in size and body condition of freshwater turtles.

20.
Rev. Fac. Med. UNAM ; 62(6): 24-27, nov.-dic. 2019. graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1149587

RESUMO

Resumen Las hernias internas son causa infrecuente de obstrucción intestinal con una incidencia del 0.2-0.9%, por lo que su diagnóstico temprano representa un reto. El órgano más frecuentemente herniado es el intestino delgado, lo que confiere un gran espectro de síntomas, desde dolor abdominal ligero hasta datos de abdomen agudo1,2. Se presenta el caso de una paciente de 8 años de edad con sintomatología digestiva inespecífica; se realizó diagnóstico transoperatorio en el que se encontró hernia interna estrangulada por plastrón en el tercio distal del apéndice. Se realizó apendicectomía y a los cuatro días se dio de alta sin complicaciones.


Abstract Internal hernias are an infrequent cause of intestinal obstruction with an incidence of 0.2-0.9%, therefore their early diagnosis represents a challenge. The most frequently herniated organ is the small bowel, which results in a wide spectrum of symptoms, varying from mild abdominal pain to acute abdomen1,2. We present the case of an eight-year old patient with nonspecific digestive symptoms, a transoperative diagnosis was made in which an internal hernia was found strangulated by plastron in the distal third of the appendix. Appendectomy was performed and four days later the patient was discharged without complications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...