RESUMO
PURPOSE: To assess the arterial suture, comparing continuous and interrupted techniques, in abdominal aorta of growing rabbbits, using two types of suture material: Polypropylene 7-0 (nonabsorbable) and Polydioxanone 7-0 (absorbable). METHODS: Groups: GI - Control, without arterial suture; GII - Polypropylene, Interrupted technique; GIII - Polipropilene, Continuous technique; GIV - Polydioxanone, Interrupted technique and GV - Polydioxanone, Continuous technique. Each group was subdivided in four Moments of Euthanasia , according with the number of days after surgery: 7 , 14 , 30 and 60 days. The following itens were assessed: weight, arterial diameters and pulse, stenosis, thrombosis, tissue adherence at the suture line, aortography, suture material visibility, suture line healling visibility and microscopic study. RESULTS: a) after 60 days, the suture line site had a significant growing in all groups; b) interrupted technique result less suture line stenosis in surgical act and in euthanasia c) the difference between groups showed in the microscopic study, was transitory, not pesisting after 60 days post surgery; CONCLUSION: Polydioxanone is better than polypropylene for suture in growing artery, not causing (or causing little) restriction to the growing of the suture line, even though using continuous technique.
OBJETIVO: Observar o comportamento da sutura arterial em aortas abdominais de coelhos em crescimento, comparando-se as técnicas contínua e com pontos separados, empregando-se dois tipos de fios: Polipropilene 7-0 (inabsorvível) e Polidioxanone 7-0 (absorvível). MÉTODOS: Grupos: GI - Controle (sem sutura); GII - Polipropilene, Pontos Separados; GIII - Polipropilene, Contínua; GIV - Polidioxanone, Pontos Separados e GV - Polidioxanone, Contínua. Cada grupo foi subdividido em quatro Momentos de Eutanásia: aos 7, 14, 30 e 60 dias de pós-operatório. Foram avaliados: peso dos animais, diâmetros e pulsos arteriais, estenose, trombose, aderências, aortografia, visibilidade do fio, cicatrização e microscopia. RESULTADOS: a) após 60 dias, o local da linha de sutura cresceu de forma significativa em todos os grupos; b) a técnica de sutura com pontos separados causou menor estenose da linha de sutura, observada tanto no ato cirúrgico, como na eutanásia dos animais; c) no exame histopatológico, as diferenças encontradas entre grupos foram transitórias, não persistindo após 60 dias de pós-operatório. CONCLUSÃO: O polidioxanone mostrou ser a melhor opção, entre os dois fios, para sutura de artérias em crescimento, pois causa pouca ou nenhuma restrição ao crescimento arterial na linha de sutura, mesmo quando se emprega a técnica contínua.
RESUMO
OBJECTIVE: To study the morphology in the rabbit's knee joint after the reparation of a defect in the osteochondral's standardized with suture wire polidioxanone, proceeded a criation of one osteochondral's defect in the medial condyle femoral in 80 rabbit's knees, albinos, males, aged between 5 and 8 months and weight between 2600 and 3000g. METHODS: The animals were distributed into 2 groups with following by 7 and 42 days and submitted to the technique A (resection and withdrawal of osteochondral's fragment in the medial condyle femoral and replacement with suture wire monofilament absorbable polidioxanone - PDX), technique B (resection and withdrawal of osteochondral's fragment in the medial condyle femoral and it is used as a autograft, after 180º rotation, in anteroposterior sense and synthesis in contralateral's knee with monofilament suture wire absorbable polidioxanone - PDX) or technique C (resection and withdrawal of osteochondral's fragment in the medial condyle femoral, leaving the standard defect empty in contralateral's knees in those which they were operated by techniques A or B) as control. RESULTS: They did clinical, radiographic, macroscopic and histological's studies in these 2 groups, showing the replacement of fragment or osteochondral's autograft, which facilities the perfect integration of fragment in the femoral condyle without shift or necrosis cartilaginous or osteal, in which knees were submitted by a simple resection of fragment, with following 42 days, there weren't cartilaginous formation in articular's surface having predispose to the osteophyte's formation, showing a significant relation between technique C and the presence of osteophytes. CONCLUSION: It comes to a conclusion that reconstitution of joint surface with replacement of fragment or osteochondral's graft fixed with suture wire PDX is feasible and it presented better result than a simple resection of the fragment.
OBJETIVO: Com a finalidade de estudar a morfologia da articulação do joelho de coelhos após a reparação de um defeito osteocondral padronizado com fio de sutura polidioxanone, procedeu-se a criação de um defeito osteocondral em côndilo femoral medial do joelho de 80 coelhos, albinos, machos, com idade entre 5 a 8 meses e peso entre 2.600 e 3.000g. MÉTODOS: Os animais foram distribuídos em 2 grupos com seguimentos de 7 e 42 dias e submetidos à técnica A (ressecção e retirada do fragmento osteocondral; recolocação e síntese de fio PDX-00), técnica B (ressecção e retirada do fragmento osteocondral; reposição como enxerto autólogo no joelho contralateral, após rotação de 180º no sentido ântero-posterior; síntese com fio PDX-00) ou técnica C (ressecção e retirada do fragmento osteocondral deixando o defeito padrão vazio, nos joelhos contralaterais aos operados pela técnica A ou B) como controle. RESULTADOS: Fez-se estudo clínico, radiográfico, macroscópico e histológico nos dois grupos mostrando que a recolocação do fragmento ou enxerto autólogo osteocondral facilita a perfeita integração dos fragmentos aos côndilos femorais, sem deslocamento ou necrose cartilaginosa ou óssea; que nos joelhos submetidos a ressecção simples do fragmento com seguimento de 42 dias, não houve formação de cartilagem na superfície articular, havendo predisposição à formação de osteofitos, mostrando relação significante entre a técnica C e a presença de osteofitos. CONCLUSÃO: Concluiu-se que a reconstituição da superfície articular com recolocação do fragmento ou o enxerto autólogo osteocondral fixado com fio de sutura PDX é exeqüível e apresentou melhor resultado do que a ressecção simples do fragmento.
RESUMO
OBJECTIVE: comparative study between the mechanical properties of the tenorraphies with poliamida (nylon) and polidioxanone (PDS). METHODS: 56 adult, male, New Zealand rabbits were used, distributed in two groups and four sub groups: GIA-tenorraphies with polidioxanone and evaluation after two weeks; GIB-tenorraphies with polidioxanone and evaluation after four weeks; GIIA-tenorraphies with nylon and evaluation after two weeks; GIIB-tenorraphies with nylon and evaluation after four weeks. Traction tests were done in tenorraphies of the rabbits. RESULTS: after fifteen days nylon presented as results of the mechanical tests, superior values that the one of PDS for maximum load, rigidity coefficient, deformation, deformation in the proportionality limit, load in the proportionality limit, that were the variable analysed. CONCLUSION: after thirty days there was not significant difference between nylon and PDS.
OBJETIVO: estabelecer comparação entre as propriedades mecânicas das tenorrafias realizadas com poliamida (náilon) e polidioxanona (PDS). MÉTODOS: Foram utilizados 56 coelhos adultos, machos, Nova Zelândia, distribuídos em dois grupos e quatro subgrupos: GIA - tenorrafias com polidioxanona e avaliação após duas semanas; GIB - tenorrafias com polidioxanona e avaliação após quatro semanas; GIIA - tenorrafias com náilon e avaliação após duas semanas; GIIB - tenorrafias com náilon e avaliação após quatro semanas. Foram realizados ensaios de tração nas tenorrafias dos tendões dos coelhos. RESULTADOS: na avaliação aos quinze dias de pós-operatório, o náilon apresentou como resultados dos ensaios mecânicos, valores superiores que os do PDS para carga máxima, coeficiente de rigidez, deformação, deformação no limite de proporcionalidade, carga no limite de proporcionalidade, que foram as variáveis analisadas. CONCLUSÃO: aos trinta dias de pós-operatório não houve diferença significante entre o uso do náilon e o PDS.