Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Small ; : e2402696, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-39152533

RESUMO

Fluoride in drinking water has beneficial or harmful health effects depending on its concentration. This highlights the need for new low-cost and portable sensors capable of in situ monitoring of F- ions. Unfortunately, achieving high levels of water compatibility and fluoride specificity remains a challenge. Here, four new urea-based discrete sensors are prepared and characterized. The sensors containing anthracenyl- (5) and 9H-fluorenyl- (7) signaling units exhibit intense luminescent emissions in dimethyl sulfoxide, the former being particularly sensitive and selective to fluoride. In water, 5 displays a superior sensitivity (871 M-1) and a detection limit (8 µm) below international guidelines, albeit with cross-sensitivity to H2PO4‾. To enhance the performance, 5 and 7 are embedded into a fluoride-imprinted polymeric matrix to give solid-state sensors (5P and 7P, respectively). 5P shows good sensitivity (360 M-1) and specificity in water. Besides, it has a low detection limit (35 µm) and a response linear range (118-6300 µm) encompassing the limit established by the Environmental Protection Agency (211 µm). Furthermore, 5P also displays good reusability and adequate recovery values in real-sample testing (102 ± 2%), constituting the first example of a low-cost anion-imprinted polymeric probe tailored for the selective sensing of fluoride in aqueous samples.

2.
Heliyon ; 9(5): e15793, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37180929

RESUMO

The extraordinary features of cerium oxide (CeO2) and zinc oxide (ZnO) nanostructures have encouraged substantial attention to those nanocomposites as probable electroactive complexes for sensing and biosensing purposes. In this study, an advanced novel factionalized CeO2/ZnO nanocomposite-aluminum wire membrane sensor was designed to assess pethidine hydrochloride (PTD) in commercial injection samples. Pethidine-reineckate (PTD-RK) was formed by mixing pethidine hydrochloride and ammonium reineckate (ARK) in the presence of polymeric matrix (polyvinyl chloride) and o-nitrophenyl octyl ether as a fluidizing agent. The functionalized nanocomposite sensor displayed a fast dynamic response and wide linearity for the detection of PTD. It also revealed excellent selectivity and sensitivity, high accuracy, and precision for the determination and quantification of PTD when compared with the unmodified sensor PTD-RK. The guidelines of analytical methodology requirements were obeyed to improve the suitability and validity of the suggested potentiometric system according to several criteria. The developed potentiometric system was suitable for the determination of PTD in bulk powder and commercial products.

3.
Nanomaterials (Basel) ; 12(13)2022 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-35808148

RESUMO

The new research presents highly conductive polymeric membranes with a large surface area to volume ratio of metal oxide nanoparticles that were used to determine atropine sulfate (AT) in commercial dosage forms. In sensing and biosensing applications, the nanomaterials zinc oxide (ZnONPs) and magnesium oxide (MgONPs) were employed as boosting potential electroactive materials. The electroactive atropine phosphotungstate (AT-PT) was created by combining atropine sulfate and phosphotungstic acid (PTA) and mixing it with polymeric polyvinyl chloride (PVC) with the plasticizer o-nitrophenyl octyl ether (o-NPOE). The modified sensors AT-PT-ZnONPs or AT-PT-MgONPs showed excellent selectivity and sensitivity for the measurements of atropine with a linear concentration range of 6.0 × 10-8 - 1.0 × 10-3 and 8.0 × 10-8 - 1.0 × 10-3 mol L-1 with regression equations of E(mV) = (56 ± 0.5) log [AT] - 294 and E(mV) = (54 ± 0.5) log [AT] - 422 for AT-PT-NPs or AT-PT-MgONPs sensors, respectively. The AT-PT coated wire sensor, on the other hand, showed a Nernstian response at 4.0 × 10-6 - 1.0 × 10-3 mol L-1 and a regression equation E(mV) = (52.1 ± 0.2) log [AT] + 198. The methodology-recommended guidelines were used to validate the suggested modified potentiometric systems against various criteria.

4.
Polymers (Basel) ; 13(24)2021 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-34961010

RESUMO

Electrically conductive polymeric nanocomposites with nanoparticles are adaptable types of nanomaterials that are prospective for various applications. The extraordinary features of copper oxide (CuO) and aluminium oxide (Al2O3) nanostructures, encourages extensive studies to prospect these metal oxide nanocomposites as potential electroactive materials in sensing and biosensing applications. This study suggested a new CuO/Al2O3 nanocomposite-based polymeric coated wire membrane sensor for estimating naltrexone hydrochloride (NTX) in commercial formulations. Naltrexone hydrochloride and sodium tetraphenylborate (Na-TPB) were incorporated in the presence of polymeric polyvinyl chloride (PVC) and solvent mediator o-nitrophenyloctyl ether (o-NPOE) to form naltrexone tetraphenylborate (NTX-TPB) as an electroactive material. The modified sensor using NTX-TPB-CuO/Al2O3 nanocomposite displayed high selectivity and sensitivity for the discrimination and quantification of NTX with a linearity range 1.0 × 10-9-1.0 × 10-2 mol L-1 and a regression equation EmV = (58.25 ± 0.3) log [NTX] + 754.25. Contrarily, the unmodified coated wire sensor of NTX-TPB exhibited a Nernstian response at 1.0 × 10-5-1.0 × 10-2 mol L-1 and a regression equation EmV = (52.1 ± 0.2) log [NTX] + 406.6. The suggested modified potentiometric system was validated with respect to various criteria using the methodology recommended guidelines.

5.
J Hazard Mater ; 365: 725-732, 2019 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-30472458

RESUMO

We have prepared polymeric films as easy-to-handle sensory materials for the colorimetric detection and quantification of phenol derivatives (phenols) in water. Phenols in water resources result from their presence in pesticides and fungicides, among other goods, and are harmful ecotoxins. Colorless polymeric films with pendant diazonium groups attached to the acrylic polymer structure were designed and prepared for use as sensory matrices to detect phenol-derived species in water. Upon dipping the sensory films into aqueous media, the material swells, and if phenols are present, they react with the diazonium groups of the polymer to render a highly colored azo group, giving rise to the recognition phenomenon. The color development can be visually followed for a qualitative determination of phenols. Additionally, quantitative analysis can be performed by two different techniques: a) by using a UV-vis spectrophotometer (limit of detection of 0.12 ppm for 2-phenylphenol) and/or b) by using a smartphone with subsequent RGB analysis (limit of detection of 30 ppb for 2-phenylphenol).

6.
Polymers (Basel) ; 8(4)2016 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-30979200

RESUMO

A series of new fluorescent dye bearing monomers, including glycomonomers, based on maleamide and maleic esteramide was synthesized. The dye monomers were incorporated by radical copolymerization into thermo-responsive poly(N­vinyl-caprolactam) that displays a lower critical solution temperature (LCST) in aqueous solution. The effects of the local molecular environment on the polymers' luminescence, in particular on the fluorescence intensity and the extent of solvatochromism, were investigated below as well as above the phase transition. By attaching substituents of varying size and polarity in the close vicinity of the fluorophore, and by varying the spacer groups connecting the dyes to the polymer backbone, we explored the underlying structure⁻property relationships, in order to establish rules for successful sensor designs, e.g., for molecular thermometers. Most importantly, spacer groups of sufficient length separating the fluorophore from the polymer backbone proved to be crucial for obtaining pronounced temperature regulated fluorescence responses.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA