BMC Musculoskelet Disord ; 24(1): 319, 2023 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-37087443

RESUMO

OBJECTIVE: To investigate whether the application of a curved rasp on the femoral side is effective in reducing the incidence of stem malalignment in total hip replacement with direct anterior approach (DAA-THA), followed by the analysis of the independent risk factors affecting stem malalignment. METHODS: Retrospective analysis was carried out covering 160 patients undergoing DAA-THA from January 2019 to December 2021, with Tri-Lock (BPS, Depuy) stem applied in all 113 patients were screened according to inclusion and exclusion criteria. The data of gender, age, body mass index, preoperative diagnoses, Dorr classification, FAR ratio, pelvic morphology ratio, WOMAC scores, were analyzed to explore the independent factors influencing the malalignment of the femoral prosthesis implantation. Then data of patients were divided into group A and group B according to whether the curved rasp was taken during the operation. The chi-square test was performed to compare the incidence of femoral stem malalignment between the two groups. RESULTS: There revealed two independent risk factors: BMI and FAR ratio that affected femoral stem malalignment. The increased BMI was associated with a higher probability of femoral stem malalignment (P<0.05), the probability of malalignment of femoral stem in FAR ratio<1 was 1.15 times higher than that in FAR>1(OR = 1.15, 95% CI: 1.03-1.28, P<0.05). Further grouping analysis showed that the incidence of femoral stem malalignment in patients with intraoperative application of curved rasp was 27%, while in patients without curved rasp, the incidence of femoral stem malalignment increased significantly to 48.7%(P<0.05). The placement angle of prosthesis in group A was significantly better than that in group B, especially mild femoral stem malalignment (0%) and severe femoral stem malalignment (2.70%), and the difference was statistically significant (P < 0.05). There found no significant difference in age, gander, intraoperative complications and last follow-up assessment of WOMAC scores between the two groups of patients. CONCLUSIONS: In DAA-THA, BMI and FAR ratio act as the independent risk factors for femoral stem malalignment. Intraoperative use of a curved rasp significantly reduces the incidence of malalignment of the femoral stem.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Estudos Retrospectivos , Fêmur/cirurgia , Resultado do Tratamento
2.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1024315

RESUMO

Objective To explore the effect and influencing factors of prosthesis placement angle on hip replacement for bone fusion of hip joint.Methods A total of 100 patients with bone fusion of hip joint who were admitted to our hospital from May 2019 to January 2022 were selected as the research objects and randomly divided into the observation group(n=50)and the control group(n=50).The prosthesis placement angle was 30° to 40° in the observation group and 41° to 50° in the control group.The clinical data,VAS score and Harris score before and after operation,and postoperative complications of the two groups were compared.The improvement of hip joint function of the two groups was compared by random walking model.According to the prognosis of patients,patients were divided into the poor prognosis group(n=32)and the good prognosis group(n=68).Univariate and multivariate Logistic regression analysis were used to analyze the independent influencing factors of the prognosis of hip replacement for bone fusion of hip joint,and a prediction model was constructed and verified.Results The Harris score 6 months after operation in the observation group was significantly higher than that in the control group(P<0.05),and there was no significant difference in VAS score before and after operation and incidence of complications after operation between the two groups(P>0.05).The results of random walking model showed that the improvement of hip joint function in the observation group was better than that in the control group.There were significant differences in age,hyperlipidemia,osteoporosis,prosthesis placement angle,intraoperative blood loss,emotional disorder,postoperative complications,rehabilitation training and postoperative outdoor activity time of patients between the good prognosis group and the poor prognosis group(P<0.05).Multivariate Logistic regression analysis showed that osteoporosis and prosthesis placement angle of 41° to 50° were the independent risk factors of the prognosis of hip replacement for bone fusion of hip joint(P<0.05),and rehabilitation training was the protective factor(P<0.05).A prediction model of the prognosis of hip replacement for bone fusion of hip joint was constructed.The calibration curve of the model fit well with the ideal curve,and the area under the receiver operating characteristic curve(AUC)was 0.854(95%CI:0.830 to 0.871),which indicates that the prediction model had good accuracy.The concordance index(C-index)of the model was 0.849(95%CI:0.817 to 0.868),which indicates that the model had high discrimination.Conclusion The prosthesis placement angle of 30° to 40° can significantly improve the postoperative hip joint function of patients,and the therapeutic effect is significant.Osteoporosis,prosthesis placement angle,and rehabilitation training are the independent influencing factors of the prognosis of hip replacement for bone fusion of hip joint.

3.
BMC Musculoskelet Disord ; 23(1): 958, 2022 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-36335347

RESUMO

BACKGROUND: The total hip arthroplasty (THA) has gained popularity in in the treatment of severe developmental dysplasia of the hip (DDH). the posterior lateral approach (PLA) has good clinical efficacy and has been confirmed by the majority clinicians. Nevertheless, controversy exists regarding longer-term benefits of the direct anterior approach (DAA). The objective of this study was to investigate the clinical efficacy and placement of S-ROM prosthesis in the treatment of severe DDH by The total hip arthroplasty (THA) with different surgical approaches. METHODS: A retrospective analysis was performed on 42 patients with severe DDH admitted to our hospital from August 2015 to February 2022, who were treated with S-ROM prosthesis for total hip arthroplasty and subtrochanteric osteotomy of the femur. They were divided into DAA group and PLA group according to different surgical approaches. Perioperative indicators and imaging data were collected. RESULTS: The surgery time, intraoperative blood loss, and creatine kinase difference in DAA group and PLA group was without a statistically significant difference (P > 0.05). The postoperative length of hospitalization was shorter in the DAA group than in the PLA group (6.50 ± 3.15 vs 9.18 ± 4.93, P = 0.045). The acetabular abduction angles、the acetabular anteversion angles, the safe area ratio, The difference of femoral eccentricity, and the vertical difference of rotation center in DAA group and PLA group, there was no statistical significance (P > 0.05). Statistically significant differences were detected the horizontal difference of rotation center (P = 0.044). CONCLUSIONS: Total hip arthroplasty with S-ROM prosthesis is a feasible procedure for severe dysplastic DDH. The clinical efficacy and prosthesis placement parameters of DAA approach are advantage to those of PLA approach.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Acetábulo/cirurgia , Resultado do Tratamento , Poliésteres
4.
J Sex Med ; 18(11): 1830-1834, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34548263

RESUMO

BACKGROUND: The 3-piece inflatable penile prosthesis includes an easy-to-use pump and fluid filled reservoir which is placed in either the space of Retzius (SOR) or in an alternative ectopic location. Reservoir placement in the SOR is a blind procedure despite the SOR being surrounded by many critical structures. To date only a handful of cadaveric studies have described the relevant anatomy. AIM: To use magnetic resonance imaging (MRI) as an in-vivo model to study relevant retropubic anatomy critical for SOR reservoir placement. METHODS: The study population included men with elevated prostate specific antigen or biopsy proven prostate cancer who (i) underwent pelvic MRI, (ii) without prior pelvic or inguinal surgery, and (iii) without pelvic radiation therapy. All MRIs were completed with a 3-Tesla scanner and endorectal coil. Both T1 and T2 weighted images were captured in both axial and sagittal planes. All images were reviewed by 2 independent reviewers under the supervision of a dedicated body MRI radiologist. Bladder volume was calculated using an ellipsoid formula. OUTCOMES: Relevant measurements included (i) the distance between the external inguinal ring (EIR) at the level of the pubic tubercle to the external iliac vein (EIV), (ii) the distance from the EIR at the pubic tubercle to the bladder (accounting for bladder volume) and (iii) the distance from the midline pubic symphysis to the bladder (accounting for bladder volume). Pearson correlation was used to determine correlated measurements. RESULTS: A total of 24 patients were included. Median participant age was 63 years (interquartile range, 59-66). The mean EIR-EIV distance was 3.0 ± 0.4 cm, the mean EIR-bladder distance was 1.8 ± 1.0 cm and the mean distance from the superior pubic symphysis to bladder was 0.9 ± 0.3 cm. There was a weak correlation between bladder volume and distance between the EIR and bladder (r = -0.30, P = .16). CLINICAL IMPLICATIONS: The use of MRI as an in-vivo model is a high-fidelity tool to study real time unaltered anatomy and allows for surgical preparation, diagnosis of anatomic variants and acts as a valuable teaching tool. STRENGTHS & LIMITATIONS: This is the first in-vivo model to report relevant retropubic anatomy in penile implant surgery. Our study is limited by sample size and inclusion of participants with no history of prior pelvic intervention. CONCLUSION: We demonstrate the utility of MRI as an in-vivo model, as opposed to cadaveric models, for the understanding of relevant retropubic anatomy for implant surgeons. Punjani N, Monteiro L, Sullivan J F et al. The Anatomical Relationships in the Space of Retzius for Penile Implants: An MRI Analysis. J Sex Med 2021;18:1830-1834.


Assuntos
Disfunção Erétil , Implante Peniano , Prótese de Pênis , Disfunção Erétil/cirurgia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Osso Púbico
5.
Curr Urol Rep ; 20(2): 9, 2019 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-30701338

RESUMO

PURPOSE OF REVIEW: The use of penile implant for the treatment of both erectile dysfunction and Peyronie's disease has changed little in the last 40 years, primarily limited to modeling and plaque incision. In the current review, I explore the history of Peyronie's treatment at the time of penile prosthesis placement and explore new surgical options that help resolve several of the issues that were not treated with the traditional approaches. RECENT FINDINGS: Advancements have been made in the area of graft material, lengthening procedures, and transcorporal techniques. The goal of these operations is not only to correct curvature, but also to restore length. Not surprisingly, the more complex and aggressive the attempt to correct the curvature, the more complications are possible. While modeling has a low rate of urethral injury, complex lengthening procedure with neurovascular bundle and urethral mobilization may lead to the dreaded complication of glans necrosis. Meanwhile, transcorporal techniques seem to offer a more modest improvement for length and curvature restoration with fewer risks than those seen in more aggressive lengthening procedures. The main limitation to the historical treatment of Peyronie's disease during penile prosthesis, modeling, and plaque incision is there is often no resolution to the penile length-as the maneuvers are made after the implant is already in place. Newer lengthening procedures are promising, however carry increased risks and complexity.


Assuntos
Implante Peniano/métodos , Induração Peniana/cirurgia , Prótese de Pênis , Pênis/cirurgia , Dissecação , História do Século XX , História do Século XXI , Humanos , Masculino , Implante Peniano/efeitos adversos , Implante Peniano/história , Induração Peniana/história , Prótese de Pênis/efeitos adversos , Prótese de Pênis/história , Pênis/patologia
6.
Appl. cancer res ; 37: 1-4, 2017. tab, ilus
Artigo em Inglês | LILACS, Inca | ID: biblio-912727

RESUMO

Background: Functional speech rehabilitation after total laryngectomy remains one of the most challenging issues in head and neck multidisciplinary care. Tracheoesophageal puncture for voice prosthesis insertion performed as a secondary procedure with a rigid esophagoscope and trocar can be technically difficult in certain patients due to post-treatment cervical abnormalities, such as reduced hyperextension, stenosis, and trismus. Methods: This study presents an improved method of secondary tracheoesophageal prosthesis insertion using a flexible endoscope in association with a plastic pliable overtube to keep the virtual esophageal lumen open. By this method, the puncture can be performed easily and safely with the avoidance of unexpected lesions. Results: From 2005 to 2015, 12 (16,9%) out of 71 patients who underwent secondary voice prosthesis placement at our institution required this alternative technique due to anatomical alterations that hindered the execution of the procedure following the standard technique. Conclusion: The procedure was successfully performed in all patients with no related complications (AU)


Assuntos
Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Reabilitação , Voz , Endoscopia , Laringectomia , Laringe Artificial