Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 162
Filtrar
1.
Eur J Med Res ; 29(1): 406, 2024 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-39103884

RESUMO

BACKGROUND: The diagnosis of peripheral pulmonary lesions (PPL) is still challenging. We describe a novel method for sampling PPL without bronchial signs by creating invisible tunnel under electromagnetic navigation without the transbronchial access tool (TABT). METHODS: During electromagnetic navigation, we adjust the angle of the edge extended working channel catheter based on the real-time position of the lesion in relation to the locating guide rather than preset route. A biopsy brush or biopsy forceps is used to punch a hole in the bronchial wall. A locating guide is then re-inserted to real-time navigate through the lung parenchyma to the lesion. Safety and feasibility of this method was analyzed. RESULTS: A total of 32 patients who underwent electromagnetic navigation bronchoscopy were retrieved. The mean size of the lesion is 23.1 mm. The mean operative time of all patients was 12.4 min. Ten of the patients did not have a direct airway to the lesion, thus creating an invisible tunnel. For them, the length of the tunnel from the bronchial wall POE to the lesion was 11-30 mm, with a mean length of 16.9 mm and a mean operation time of 14.1 min. Adequate samples were obtained from 32 patients (100%), and the diagnostic yield was 87.5% (28/32). Diagnostic yield of with create the invisible tunnel TBAT was 90% (9/10), and one patient undergone pneumothorax after operation. CONCLUSIONS: This method is feasible and safe as a novel approach sampling pulmonary lesions without bronchial signs, and it further improves current tunnel technique.


Assuntos
Broncoscopia , Fenômenos Eletromagnéticos , Humanos , Broncoscopia/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Adulto , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/cirurgia , Brônquios/patologia , Brônquios/diagnóstico por imagem , Idoso de 80 Anos ou mais
2.
Expert Rev Med Devices ; : 1-9, 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39107968

RESUMO

BACKGROUND: The diagnosis of peripheral pulmonary lesions (PPLs) remains challenging. Despite advancements in guided transbronchial biopsy (TBB) techniques, diagnostic yields haven't reached ideal levels. Optical coherence tomography (OCT) has been developed for application in pulmonary diseases, yet no data existed evaluating effectiveness in diagnosing PPLs. RESEARCH DESIGN AND METHODS: This study included patients who underwent OCT and radial endobronchial ultrasound (R-EBUS)-guided TBB. OCT and R-EBUS imaging features were analyzed to differentiate between benign and malignant PPLs and subtypes of lung cancer. RESULTS: A total of 89 patients were included in this study. The diagnostic yield of OCT-guided TBB stood at 56.18%, R-EBUS-guided TBB was 83.15% (P<0.01). The accuracy of OCT to judge the nature of lesions was 92.59%, while R-EBUS was 77.92%. The accuracy of OCT in predicting squamous carcinoma (SCC) and adenocarcinoma were both 91.30%. CONCLUSIONS: Although the diagnostic yield of OCT-guided TBB fell short of that achieved by R-EBUS, OCT possessed the capability to judge the nature of lesions and guide the pathological classification of malignant lesions. Further extensive prospective studies are necessary to thoroughly assess the characteristics of this procedure. CLINICAL TRIAL REGISTRATION: https://register.clinicaltrials.gov/ identifier is NCT06419114.

3.
Ultrasound Med Biol ; 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39068137

RESUMO

OBJECTIVE: The purpose of this study was to analyze the independent risk factors of malignant subpleural pulmonary lesions (SPLs) on B-mode ultrasound (US) images, to construct the combined predictive indicators, and to prospectively verify their predictive efficacy. METHODS: A total of 336 patients with SPLs were included in the prospective study, of whom the single-center included patients between September 2019 and December 2019 were the development cohort (DC) (n = 219); Patients who were concurrently enrolled in three centers between January and February 2020 were the validation cohort (VC) (n = 117). The clinical features and B-mode US parameters were collected. Based on the DC, a combined predictive indicators model was developed using binary logistic regression. Then the discrimination was verified externally in the VC. The reference criteria were from the comprehensive diagnosis of clinical-radiological-pathological made by two senior respiratory physicians. RESULTS: The combined predictive indicators model was finally constructed by five parameters: age, borderline, angle between the lesion border and thoracic wall, posterior echo of the lesion and invasion of the pleura. The fitting degree of the model was good (χ2 = 9.198, p = 0.326). The area under ROC curve of the model was 0.872 (DC) and 0.808 (VC), yielding a higher net benefit than individual risk factors. CONCLUSION: The combined predictive indicators are useful in the assessment of malignant SPLs and are a useful adjunct diagnostic tool, especially in primary healthcare settings in developing countries.

4.
Clin Respir J ; 18(7): e13792, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39072902

RESUMO

OBJECTIVE: To evaluate the predictive value of echo features of radial probe endobronchial ultrasound (RP-EBUS) in the differential diagnosis of malignant and benign 1esions. METHODS: The clinical data of 336 patients with peripheral pulmonary lesions (PPLs) undergoing RP-EBUS were analyzed in order to evaluate the predictive value of the three EBUS echo features including continuous margin, absence of a linear-discrete air bronchogram, and heterogeneous in pulmonary lesions. The sensitivity and specificity for each echoic feature or in combination in diagnosing malignancy or benignity were determined. RESULTS: 336 cases of PPLs including 216 cases of malignant lesions and 120 cases of benign lesions. The sensitivity and specificity of the continuous margin to the diagnosis of malignant lesions were 86.11% and 17.50%. The sensitivity and specificity of the absence of a linear-discrete air bronchogram to the diagnosis of malignant lesions were 66.67% and 57.50%, and the positive predictive value was 73.85%. The sensitivity and specificity of heterogeneity to the diagnosis of malignant lesions were 65.28% and 72.50%, and the positive predictive value was 81.03%. The combination of heterogeneous and absence of a linear-discrete air bronchogram could improve the diagnostic specificity to 87.50%, and the positive predictive value to 80.77%. CONCLUSION: The two EBUS echo features of heterogeneous and absence of a linear-discrete air bronchogram have predictive value for PPLs, especially in the presence of two features the pulmonary lesions should be highly suspected malignant tumors.


Assuntos
Broncoscopia , Endossonografia , Neoplasias Pulmonares , Sensibilidade e Especificidade , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Idoso , Endossonografia/métodos , Diagnóstico Diferencial , Broncoscopia/métodos , Adulto , Estudos Retrospectivos , Valor Preditivo dos Testes , Pulmão/diagnóstico por imagem , Pulmão/patologia , Idoso de 80 Anos ou mais
5.
Healthcare (Basel) ; 12(13)2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38998796

RESUMO

(1) Objective: Lung cancer is one of the leading causes of cancer death among men and women across the globe. The accurate and timely diagnosis of lung lesions is of paramount importance for prognosis. This single-center study is the first to assess the diagnostic yield and complication rate of a computed tomography (CT)-guided needle biopsy of pulmonary parenchymal and pleural nodules in an academic training center in the United States. (2) Methods: This is a retrospective study approved by IRB. Patients who underwent CT-guided needle biopsy between 2016 and 2020 were reviewed. A CT-guided needle biopsy involving mediastinal lesions was excluded, focusing only on lung parenchymal and pleural lesions. A CT-guided needle biopsy aborted at any point during the procedure was also excluded from this study. (3) Results: 1063 patients were included in this study; 532 were males, and 531 were females. Lesion size ranged from 0.26 cm to 9.2 cm. 1040 patients received diagnoses, among which 772 had a specific diagnosis, and 268 had nonspecific inflammatory or non-malignant diagnoses. Twenty-three cases were non-diagnostic. Among the patients with specific diagnoses, 691 were malignant, 5 were hamartomas, 30 were fungal infections, 6 were acid-fast-positive organisms, and 40 were unspecified atypical cells. Of the patients that had a malignant diagnosis, 317 were adenocarcinoma, 197 were squamous cell carcinoma, 26 were a neuroendocrine tumor, 45 were non-small cell carcinoma (undifferentiated), 17 were small cell carcinoma, and 89 were other metastatic malignancies to the lung. Various common complications, including pneumothorax (337), hemorrhage (128), and hemoptysis (17), were observed, and 42 of the cases required chest tube intervention; others were treated with observation. Other rare complications observed included hemothorax (4) and oxygen desaturation (2), and there was no death in this series. (4) Conclusions: CT-guided needle biopsy is a reliable diagnostic modality for patients with lung parenchymal and pleural nodules, and it can effectively distinguish between benign and cancerous lesions before invasive procedures such as video-assisted thoracoscopy (VATs) or thoracotomy are planned. Our study showed a higher rate of pneumothorax and pulmonary hemorrhage compared to the rates established in guidelines, attributable to the varying experience level in a busy training academic center.

6.
Cureus ; 16(6): e62532, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38887749

RESUMO

Lung cancer, a leading cause of global cancer-related deaths, necessitates the development of innovative diagnostic techniques. Traditional bronchoscopy, while useful, has limitations in diagnosing peripheral pulmonary lesions (PPLs) and carries a higher risk of complications such as pneumothorax. However, the field of interventional pulmonology has seen significant advancements, including the introduction of robotic-assisted bronchoscopy (RAB), cone-beam computed tomography (CBCT), radial endobronchial ultrasound (R-EBUS), and rapid on-site evaluation (ROSE). These advancements have greatly improved the precision of diagnosing high-risk PPLs. This report presents the case of a 60-year-old female smoker with chronic obstructive pulmonary disease and extensive centrilobular emphysema, who had a peripherally located high-risk pulmonary nodule. She was successfully diagnosed with metastatic adenocarcinoma using an integrated approach, despite the challenging location of the lesion and high risk of pneumothorax. The integration of RAB with CBCT and augmented fluoroscopy offers a groundbreaking approach for diagnosing and managing difficult-to-reach, high-risk pulmonary nodules, marking a significant stride in the field of interventional pulmonology.

7.
Pathogens ; 13(6)2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38921814

RESUMO

The efficacy of an intranasal (IN) bovine respiratory syncytial virus (BRSV) vaccine administered in the presence of passive immunity was assessed. Pooled colostrum was administered by intubation to 50 beef-dairy crossbred calves the day they were born. The calves were transported to a research facility and were blocked by age and sex, and randomly assigned into two groups: sham-vaccinated intranasally with a placebo (sterile water) or vaccinated with a trivalent (BRSV, bovine herpesvirus 1 and bovine parainfluenza 3) modified live viral (MLV) vaccine. The calves were 9 ± 2 days old when vaccinated (day 0). The calves were challenged by aerosolized BRSV on days 80 and 81 as a respiratory challenge. The study was terminated on day 88. Lung lesion scores (LLS) were significantly lower for calves vaccinated with trivalent MLV vaccine than those for calves that were sham-vaccinated. Serum neutralization (SN) antibody against BRSV in calves vaccinated with the trivalent MLV vaccine demonstrated an anamnestic response on day 88. After challenge, the calves sham-vaccinated with the placebo lost weight, while those vaccinated with the trivalent MLV vaccine gained weight. In this study, colostrum-derived antibodies did not interfere with the immune response or protection provided by one dose of the trivalent MLV vaccine.

8.
Folia Med (Plovdiv) ; 66(2): 179-187, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38690812

RESUMO

INTRODUCTION: Evaluation of patients with peripheral lung lesions and lesions of the chest wall and mediastinum is challenging. The nature of the lesion identified by imaging studies can be determined by histological evaluation of biopsies. An important place in this direction is the ever-increasing popularity among thoracic surgeons of the transthoracic biopsy with a cutting needle under ultrasound control (US-TTCNB).


Assuntos
Mediastino , Parede Torácica , Humanos , Biópsia por Agulha/efeitos adversos , Biópsia por Agulha/métodos , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/métodos , Pulmão/patologia , Pulmão/diagnóstico por imagem , Pneumopatias/patologia , Pneumopatias/diagnóstico por imagem , Pneumopatias/etiologia , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Mediastino/patologia , Mediastino/diagnóstico por imagem , Parede Torácica/diagnóstico por imagem , Parede Torácica/patologia
9.
Front Oncol ; 14: 1373286, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38779097

RESUMO

Purpose: This study aimed to investigate the characteristics of various pulmonary lesions as revealed by 68Ga-FAPI PET/CT and to determine the utility of 68Ga-FAPI PET/CT in distinguishing the nature of these pulmonary lesions. Methods: A retrospective analysis was conducted on 99 patients with pulmonary lesions, who were categorized into three distinct groups: primary lung tumors (G1), metastatic lung tumors (G2), and benign lesions (G3). Each participant underwent a 68Ga-FAPI PET/CT scan. Among these groups, variables such as the Tumor/Background Ratio (TBR), Maximum Standardized Uptake Value (SUVmax), and the true positive rate of the lesions were compared. Furthermore, the FAPI uptake in nodular-like pulmonary lesions (d<3cm) and those with irregular borders was evaluated across the groups. A correlation analysis sought to understand the relationship between FAPI uptake in primary and pulmonary metastatic lesions. Results: The study's participants were composed of 52 males and 47 females, with an average age of 56.8 ± 13.2 years. A higher uptake and detection rate for pulmonary lesions were exhibited by Group G1 compared to the other groups (SUVmax [G1 vs. G2 vs. G3: 9.1 ± 4.1 vs. 6.1 ± 4.1 vs. 5.3 ± 5.8], P<0.05; TBR [G1 vs. G2 vs. G3: 6.2 ± 2.4 vs. 4.1 ± 2.2 vs. 3.2 ± 2.7], P<0.01; true positive rate 95.1% vs. 88% vs. 75.6%]. In nodular-like lung lesions smaller than 3 cm, G1 showed a significantly higher FAPI uptake compared to G2 and G3 (SUVmax [G1 vs. G2 vs. G3: 8.8 ± 4.3 vs. 5.2 ± 3.2 vs. 4.9 ± 6.1], P<0.01; TBR [G1 vs. G2 vs. G3: 5.7 ± 2.7 vs. 3.7 ± 2.1 vs. 3.3 ± 4.4], P<0.05). Both G1 and G2 demonstrated significantly elevated FAPI agent activity in irregular-bordered pulmonary lesions when compared to G3 (SUVmax [G1 vs. G2 vs. G3: 10.9 ± 3.3 vs. 8.5 ± 2.7 vs. 4.6 ± 2.7], P<0.01; TBR [G1 vs. G2 vs. G3: 7.2 ± 2.1 vs. 6.4 ± 1.3 vs. 3.2 ± 2.4], P<0.01). A positive correlation was identified between the level of 68Ga-FAPI uptake in primary lesions and the uptake in pulmonary metastatic lesions within G2 (r=0.856, P<0.05). Conclusion: 68Ga-FAPI PET/CT imaging proves to be of significant value in the evaluation of pulmonary lesions, offering distinctive insights into their nature.

10.
J Cardiothorac Surg ; 19(1): 304, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38816751

RESUMO

BACKGROUND: This retrospective study aimed to compare the efficacy and safety of one-stage computed tomography (OSCT)- to that of two-stage computed tomography (TSCT)-guided localization for the surgical removal of small lung nodules. METHODS: We collected data from patients with ipsilateral pulmonary nodules who underwent localization before surgical removal at Veteran General Hospital Kaohsiung between October 2017 and January 2022. The patients were divided into the OSCT and TSCT groups. RESULTS: We found that OSCT significantly reduced the localization time and risky time compared to TSCT, and the success rate of localization and incidence of pneumothorax were similar in both groups. However, the time spent under general anesthesia was longer in the OSCT group than in the TSCT group. CONCLUSIONS: The OSCT-guided approach to localize pulmonary nodules in hybrid operation room is a safe and effective technique for the surgical removal of small lung nodules.


Assuntos
Neoplasias Pulmonares , Tomografia Computadorizada por Raios X , Humanos , Estudos Retrospectivos , Masculino , Tomografia Computadorizada por Raios X/métodos , Feminino , Pessoa de Meia-Idade , Neoplasias Pulmonares/cirurgia , Neoplasias Pulmonares/diagnóstico por imagem , Idoso , Pneumonectomia/métodos , Nódulos Pulmonares Múltiplos/cirurgia , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulo Pulmonar Solitário/cirurgia , Nódulo Pulmonar Solitário/diagnóstico por imagem , Cirurgia Assistida por Computador/métodos
11.
Heliyon ; 10(8): e29446, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38660275

RESUMO

Background: The diagnostic yield of radial endobronchial ultrasound (r-EBUS) for the diagnosis of peripheral pulmonary lesions (PPLs) varies between studies and is affected by multiple factors. We aimed to evaluate the efficacy and safety of r-EBUS, and to explore the factors influencing the diagnostic yield of r-EBUS in patients with PPLs. Methods: The PubMed, Web of Science, and EMBASE databases were searched to identify relevant studies that used r-EBUS for diagnosing PPLs from the date of inception to Dec 2022. Meta-analysis was conducted using Review Manager 5.4 and Stata 15.1. Results: An analysis of 46 studies with a total of 7252 PPLs was performed. The pooled diagnostic yield of r-EBUS was 73.4 % (95 % CI: 69.9%-76.7 %), with significant heterogeneity detected among studies (I2 = 90 %, P < 0.001). Further analysis demonstrated PPLs located in the middle or lower lobe, >2 cm in size, malignant in type, solid in appearance on computerized tomography (CT), present in bronchus sign, the within probe location, and the addition of rapid on-site evaluation (ROSE) were associated with increased diagnostic yield, whereas use of a guide sheath (GS), bronchoscopy type, and a multimodality approach failed to influence the outcome. The pooled incidence rates of overall complications, pneumothorax and moderate and severe bleeding were 3.1 % (95 % CI: 2.1%-4.3 %), 0.4 % (95 % CI: 0.1%-0.7 %) and 1.1 % (95 % CI: 0.5%-2.0 %), respectively. Conclusions: r-EBUS has an appreciable diagnostic yield and an excellent safety manifestation when used to deal with PPLs.

12.
J Nucl Med ; 65(6): 872-879, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38604763

RESUMO

PET using 68Ga-labeled fibroblast activation protein (FAP) inhibitors (FAPIs) holds high potential for diagnostic imaging of various malignancies, including lung cancer (LC). However, 18F-FDG PET is still the clinical gold standard for LC imaging. Several subtypes of LC, especially lepidic LC, are frequently 18F-FDG PET-negative, which markedly hampers the assessment of single pulmonary lesions suggestive of LC. Here, we evaluated the diagnostic potential of static and dynamic 68Ga-FAPI-46 PET in the 18F-FDG-negative pulmonary lesions of 19 patients who underwent surgery or biopsy for histologic diagnosis after PET imaging. For target validation, FAP expression in lepidic LC was confirmed by FAP immunohistochemistry. Methods: Hematoxylin and eosin staining and FAP immunohistochemistry of 24 tissue sections of lepidic LC from the local tissue bank were performed and analyzed visually. Clinically, 19 patients underwent static and dynamic 68Ga-FAPI-46 PET in addition to 18F-FDG PET based on individual clinical indications. Static PET data of both examinations were analyzed by determining SUVmax, SUVmean, and tumor-to-background ratio (TBR) against the blood pool, as well as relative parameters (68Ga-FAPI-46 in relation to18F-FDG), of histologically confirmed LC and benign lesions. Time-activity curves and dynamic parameters (time to peak, slope, k 1, k 2, k 3, and k 4) were extracted from dynamic 68Ga-FAPI-46 PET data. The sensitivity and specificity of all parameters were analyzed by calculating receiver-operating-characteristic curves. Results: FAP immunohistochemistry confirmed the presence of strongly FAP-positive cancer-associated fibroblasts in lepidic LC. LC showed markedly elevated 68Ga-FAPI-46 uptake, higher TBRs, and higher 68Ga-FAPI-46-to-18F-FDG ratios for all parameters than did benign pulmonary lesions. Dynamic imaging analysis revealed differential time-activity curves for LC and benign pulmonary lesions: initially increasing time-activity curves with a decent slope were typical of LC, and steadily decreasing time-activity curve indicated benign pulmonary lesions, as was reflected by a significantly increased time to peak and significantly smaller absolute values of the slope for LC. Relative 68Ga-FAPI-46-to-18F-FDG ratios regarding SUVmax and TBR showed the highest sensitivity and specificity for the discrimination of LC from benign pulmonary lesions. Conclusion: 68Ga-FAPI-46 PET is a powerful new tool for the assessment of single 18F-FDG-negative pulmonary lesions and may optimize patient stratification in this clinical setting.


Assuntos
Fluordesoxiglucose F18 , Neoplasias Pulmonares , Tomografia por Emissão de Pósitrons , Humanos , Masculino , Feminino , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/metabolismo , Pessoa de Meia-Idade , Idoso , Tomografia por Emissão de Pósitrons/métodos , Idoso de 80 Anos ou mais , Compostos Radiofarmacêuticos , Adulto , Quinolinas
13.
Cureus ; 16(3): e55595, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38576679

RESUMO

We evaluated the usefulness of endobronchial ultrasonography with guide sheath (EBUS-GS) for the diagnosis of peripheral pulmonary lesions (PPLs) in Japan. We searched the PubMed/Medline database using the keywords "EBUS guide sheath" for Japanese studies on EBUS-GS published between January 2004 and August 2023. We included 32 original articles that evaluated the diagnostic yield of EBUS-GS for PPLs. Case reports and conference abstracts were excluded due to limited information available for quality assessment. The diagnostic yield of EBUS-GS was 73.6% for 2996 malignant lesions, 65.4% for 752 ground-glass nodules, 59.4% for 414 benign lesions, 61.3% for 1114 lesions of size ≤2 cm, and 75.6% for 1246 lesions of size >2 cm; it was 69.4% for lesions located in the upper lobe (n=793), 71.9% for the middle lobe/lingula (n=121), and 62.5% for the lower lobe (n=334). None of the patients experienced severe complications. In this review, EBUS-GS is effective for the diagnosis of malignant and benign PPLs. A multimodality approach is needed to further enhance its diagnostic performance.

14.
Front Oncol ; 14: 1352028, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38529369

RESUMO

Rationale and objectives: To construct a predictive model for benign and malignant peripheral pulmonary lesions (PPLs) using a random forest algorithm based on grayscale ultrasound and ultrasound contrast, and to evaluate its diagnostic value. Materials and methods: We selected 254 patients with PPLs detected using chest lung computed tomography between October 2021 and July 2023, including 161 malignant and 93 benign lesions. Relevant variables for judging benign and malignant PPLs were screened using logistic regression analysis. A model was constructed using the random forest algorithm, and the test set was verified. Correlations between these relevant variables and the diagnosis of benign and malignant PPLs were evaluated. Results: Age, lesion shape, size, angle between the lesion border and chest wall, boundary clarity, edge regularity, air bronchogram, vascular signs, enhancement patterns, enhancement intensity, homogeneity of enhancement, number of non-enhancing regions, non-enhancing region type, arrival time (AT) of the lesion, lesion-lung AT difference, AT difference ratio, and time to peak were the relevant variables for judging benign and malignant PPLs. Consequently, a model and receiver operating characteristic curve were constructed with an AUC of 0.92 and an accuracy of 88.2%. The test set results showed that the model had good predictive ability. The index with the highest correlation for judging benign and malignant PPLs was the AT difference ratio. Other important factors were lesion size, patient age, and lesion morphology. Conclusion: The random forest algorithm model constructed based on clinical data and ultrasound imaging features has clinical application value for predicting benign and malignant PPLs.

15.
Respir Res ; 25(1): 65, 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38317222

RESUMO

BACKGROUND: Endobronchial ultrasound (EBUS) and cone-beam computed tomography-derived augmented fluoroscopy (CBCT-AF) are utilized for the diagnosis of peripheral pulmonary lesions (PPLs). Combining them with transbronchial cryobiopsy (TBC) can provide sufficient tissue for genetic analysis. However, cryoprobes of different sizes have varying degrees of flexibility, which can affect their ability to access the target bronchus and potentially impact the accuracy. The aim of this study was to compare the diagnostic efficacy of cryoprobes of varying sizes in CBCT-AF and EBUS for the diagnosis of PPLs. METHODS: Patients who underwent endobronchial ultrasound-guided transbronchial biopsy (EBUS-TBB) and TBC combined with CBCT-AF for PPLs diagnosis between January 2021 and May 2022 were included. Propensity score matching and competing-risks regression were utilized for data analysis. Primary outcome was the diagnostic accuracy of TBC. RESULTS: A total of 284 patients underwent TBC, with 172 using a 1.7-mm cryoprobe (1.7 group) and 112 using a 1.1-mm cryoprobe (1.1 group). Finally, we included 99 paired patients following propensity score matching. The diagnostic accuracy of TBC was higher in the 1.1 group (80.8% vs. 69.7%, P = 0.050), with a similar rate of complications. Subgroup analysis also revealed that the 1.1 group had better accuracy when PPLs were located in the upper lobe (85.2% vs. 66.1%, P = 0.020), when PPLs were smaller than 20 mm (78.8% vs. 48.8%, P = 0.008), and when intra-procedural CBCT was needed to be used (79.5% vs. 42.3%, P = 0.001). TBC obtained larger specimens than TBB in both groups. There is still a trend of larger sample size obtained in the 1.7 group, but there is no statistically different between our two study groups (40.8 mm2 vs. 22.0 mm2, P = 0.283). CONCLUSIONS: The combination of TBC with CBCT-AF and EBUS is effective in diagnosing PPLs, and a thin cryoprobe is preferred when the PPLs located in difficult areas.


Assuntos
Pneumopatias , Neoplasias Pulmonares , Humanos , Pneumopatias/diagnóstico , Broncoscopia , Biópsia Guiada por Imagem , Neoplasias Pulmonares/patologia , Biópsia , Tomografia Computadorizada de Feixe Cônico , Fluoroscopia , Estudos Retrospectivos
16.
J Thorac Dis ; 16(1): 450-456, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38410559

RESUMO

Background: Radial probe endobronchial ultrasound (R-EBUS) is often utilized in guided bronchoscopy for the diagnosis of peripheral pulmonary lesions. R-EBUS probe positioning has been shown to correlate with diagnostic yield, but overall diagnostic yield with this technology has been inconsistent across the published literature. Currently there is no standardization for R-EBUS image interpretation, which may result in variability in grading concentricity of lesions and subsequently procedure performance. This was a survey-based study evaluating variability among practicing pulmonologists in R-EBUS image interpretation. Methods: R-EBUS images from peripheral bronchoscopy cases were sent to 10 practicing Interventional Pulmonologists at two different time points (baseline and 3 months). Participants were asked to grade the images as concentric, eccentric, or no image. Cohen's Kappa-coefficient was calculated for inter- and intra-observer variability. Results: A total of 100 R-EBUS images were included in the survey. There was 100% participation with complete survey responses from all 10 participants. Overall kappa-statistic for inter-observer variability for Survey 1 and 2 was 0.496 and 0.477 respectively. Overall kappa-statistic for intra-observer variability between the two surveys was 0.803. Conclusions: There is significant variability between pulmonologists when characterizing R-EBUS images. However, there is strong intra-rater agreement from each participant between surveys. A standardized approach and grading system for radial EBUS patterns may improve inter-observer variability in order to optimize our clinical use and research efforts in the field.

17.
J Am Vet Med Assoc ; 262(1): 1-7, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37922706

RESUMO

OBJECTIVE: Deep-seated pulmonary lesions can be difficult to sample safely. The objective of this study was to determine the relative safety and accuracy of fluoroscopy-guided fine-needle aspiration of deep-seated pulmonary lesions regardless of their size and depth. ANIMALS: Client-owned animals; 5 dogs and 5 cats. CLINICAL PRESENTATION: Pulmonary lesion locations were determined on dorsoventral and lateral views using fluoroscopy. The lateral thoracic wall was aseptically scrubbed, and an indelible marker was used to mark the point of entry of the needle for sampling. The path of a 22-gauge needle attached to a syringe was followed using fluoroscopic guidance. Mass volume (Vma) and distance from skin and pleura to lesion (DSK-L and DPL-L) were recorded. RESULTS: In dogs, mean Vma was 137.2 cm3 (range, 6.3 to 426.2 cm3). Mean DSK-L was 71 mm (range, 37 to 101 mm) and DPL-L was 33 mm (range, 16 to 71 mm). Exfoliative cytology results were consistent with carcinoma in 4 dogs and lymphoma in 1 dog. A minor postprocedural complication was noted in 1 dog. In cats, the mean Vma was 2.4 cm3 (range, 1.6 to 3.7 cm3). Mean DSK-L was 42 mm (range, 20 to 75 mm) and DPL-L was 21 mm (range, 12 to 32 mm). Cytology results were consistent with pulmonary carcinoma in 2 cats, inflammation in 2 cats, and necrotic debris in 1 cat. CLINICAL RELEVANCE: Fluoroscopy-guided fine-needle aspiration of pulmonary masses is a safe and accurate technique to obtain cytologic samples irrespective of the size and depth of the lesions.


Assuntos
Carcinoma , Doenças do Gato , Doenças do Cão , Humanos , Gatos , Cães , Animais , Biópsia por Agulha Fina/veterinária , Doenças do Gato/diagnóstico por imagem , Doenças do Gato/patologia , Doenças do Cão/diagnóstico por imagem , Doenças do Cão/patologia , Carcinoma/veterinária , Fluoroscopia/veterinária
18.
Pulmonology ; 2023 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-37914556

RESUMO

An increasing number of peripheral pulmonary lesions (PPLs) requiring tissue verification to establish a definite diagnosis for further individualized management are detected due to the growing adoption of lung cancer screening by chest computed tomography (CT), especially low-dose CT. However, the morphological diagnosis of PPLs remains challenging. Transbronchial lung cryobiopsy (TBLC) that can retrieve larger specimens with more preserved cellular architecture and fewer crush artifacts in comparison with conventional transbronchial forceps biopsy (TBFB), as an emerging technology for diagnosing PPLs, has been demonstrated to have the potential to resolve the clinical dilemma pertaining to currently available sampling devices (e.g., forceps, needle and brush) and become a diagnostic cornerstone for PPLs. Of note, with the introduction of the 1.1 mm cryoprobe that will be more compatible with advanced bronchoscopic navigation techniques, such as radial endobronchial ultrasound (r-EBUS), virtual bronchoscopic navigation (VBN) and electromagnetic navigation bronchoscopy (ENB), the use of TBLC is expected to gain more popularity in the diagnosis of PPLs. While much remains for exploration using the TBLC technique for diagnosing PPLs, it can be envisaged that the emergence of additional studies with larger data accrual will hopefully add to the body of evidence in this field.

19.
Animals (Basel) ; 13(22)2023 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-38003081

RESUMO

This study on veal calf respiratory disease assessed the association between an on-farm clinical scoring system and lung ultrasonography with the postmortem inspection of the lungs. The comparisons allowed the calculation of predictive values of the diagnostic methods. In total, 600 calves on an Austrian veal calf farm were examined at the beginning and the end of the fattening period. Overall, the area under the curve (AUC) for ultrasonographic scores was 0.90 (rsp = 0.78) with a sensitivity (Se) of 0.86. The specificity (Sp) was 0.78, and the positive predictive value (PPV) was 0.74. The AUC for the physical examination was 0.76 (rsp = 0.55) with a Se of 0.64, an Sp of 0.81, and a PPV of 0.69. For the combination of ultrasonography and physical examination, an AUC curve of 0.85 (rsp = 0.69) was calculated. A Se of 0.65 and a Sp of 0.88 with a PPV of 0.73 was calculated. This study concluded that both physical and ultrasonographic examination scoring are reliable examination methods for the detection of lung diseases in veal calves.

20.
Quant Imaging Med Surg ; 13(9): 5579-5592, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37711783

RESUMO

Background: To investigate the value of quantitative parameters related to static imaging and fast kinetics imaging of total-body (TB) 2-[18F]-fluoro-2-deoxy-D-glucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) in differentiating benign from malignant pulmonary lesions and squamous cell carcinoma (SCC) from adenocarcinoma (AC) and to analyze the correlation of each parameter with the Ki-67 index. Methods: A total of 108 patients with pulmonary lesions from July 2021 to May 2022 in the Henan Provincial People's Hospital, China, were consecutively recruited for TB 18F-FDG PET/CT in this prospective study. Static imaging parameters maximum standardized uptake value (SUVmax) and fast kinetics imaging parameters transport constant (K1), rate constants (k2), time delay (td), and fractional blood volume (vb) were calculated and compared. The area under the receiver operating characteristic (ROC) curve (AUC), Delong test, Logistic regression analyses, and Pearson correlation were used to assess diagnostic efficacy, find independent predictors and analyse correlations respectively. Results: Malignant lesions had higher SUVmax and K1 and lower vb than benign lesions, and SCC had higher SUVmax and K1 and lower td and vb than AC (all P<0.05). For the differentiation of benign and malignant lesions, SUVmax, K1, and vb were independent predictors, and AUC (SUVmax + K1+ vb) =0.909 (95% CI: 0.839-0.956), AUC (SUVmax) =0.883 (95% CI: 0.807-0.937), AUC (K1) =0.810 (95% CI: 0.723-0.879), and AUC (vb) =0.746 (95% CI: 0.653-0.825), where AUC (SUVmax + K1+ vb) was significantly different from AUC (K1), AUC (vb) (Z=3.006, 3.965, all P<0.05). For the differentiation of SCC and AC, SUVmax, K1, td, and vb were independent predictors, and AUC (SUVmax + K1+ td + vb) =0.946 (95% CI: 0.840-0.991), AUC (SUVmax) =0.818 (95% CI: 0.680-0.914), AUC (K1) =0.770 (95% CI: 0.626-0.879), AUC (vb) =0.737 (95% CI: 0.590-0.853), and AUC (td) =0.669 (95% CI: 0.510-0.791), where AUC (SUVmax + K1+ td + vb) was significantly different from AUC (SUVmax), AUC (K1), AUC (vb), and AUC (td) (Z=2.269, 2.821, 2.848, and 3.276, all P<0.05). SUVmax and K1 were moderately and mildly positively correlated with the Ki-67 index (r=0.541, 0.452, all P<0.05), respectively. Conclusions: Quantitative parameters of static imaging and fast kinetics imaging in 18F-FDG total-body PET/CT can be used to differentiate benign from malignant pulmonary lesions and SCC from AC and to assess Ki-67 expression.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...