RESUMO
Instead of typical household trash, the heavy metal complexes, organic chemicals, and other poisons produced by huge enterprises threaten water systems across the world. In order to protect our drinking water from pollution, we must keep a close eye on the situation. Nanotechnology, specifically two-dimensional (2D) nanomaterials, is used in certain wastewater treatment systems. Graphene, g-C3N4, MoS2, and MXene are just a few examples of emerging 2D nanomaterials that exhibit an extraordinary ratio of surface (m3), providing material consumption, time consumption, and treatment technique for cleaning and observing water. In this post, we'll talk about the ways in which 2D nanomaterials may be tuned to perform certain functions, namely how they can be used for water management. The following is a quick overview of nanostructured materials and its possible use in water management: Also discussed in length are the applications of 2D nanomaterials in water purification, including pollutant adsorption, filtration, disinfection, and photocatalysis. Fluorescence sensors, colorimetric, electrochemical, and field-effect transistors are only some of the devices being studied for their potential use in monitoring water quality using 2D nanomaterials. Utilizing 2D content has its benefits and pitfalls when used to water management. New developments in this fast-expanding business will boost water treatment quality and accessibility in response to rising awareness of the need of clean, fresh water among future generations.
Em vez do lixo doméstico típico, os complexos de metais pesados, produtos químicos orgânicos e outros venenos produzidos por grandes empresas ameaçam os sistemas de água em todo o mundo. Para proteger nossa água potável da poluição, devemos ficar de olho na situação. A nanotecnologia, especificamente nanomateriais bidimensionais (2D), é usada em certos sistemas de tratamento de águas residuais. Grafeno, g-C3N4, MoS2 e MXene são apenas alguns exemplos de nanomateriais 2D emergentes que exibem uma extraordinária proporção de superfície (m3), proporcionando consumo de material, consumo de tempo e técnica de tratamento para limpeza e observação da água. Neste trabalho, trataremos das maneiras pelas quais os nanomateriais 2D podem ser ajustados para desempenhar determinadas funções, ou seja, como eles podem ser usados para o gerenciamento de água. A seguir, uma breve visão geral dos materiais nanoestruturados e seu possível uso no gerenciamento de água. Serão também discutidas detalhadamente as aplicações de nanomateriais 2D na purificação de água, incluindo adsorção de poluentes, filtração, desinfecção e fotocatálise. Sensores de fluorescência, colorimétricos, eletroquímicos e transistores de efeito de campo são apenas alguns dos dispositivos que estão sendo estudados para uso potencial no monitoramento da qualidade da água usando nanomateriais 2D. A utilização de conteúdo 2D tem seus benefícios e armadilhas quando utilizada para gerenciamento de água. Novos desenvolvimentos neste negócio em rápida expansão visam aumentar a qualidade e a acessibilidade do tratamento de água em resposta à crescente conscientização sobre a necessidade de água limpa e fresca entre as gerações futuras.
Assuntos
Poluição da Água/prevenção & controle , Monitoramento da Água , Purificação da Água , NanoestruturasRESUMO
Abstract Population growth and urbanization pose a greater pressure for the treatment of drinking water. Additionally, different treatment units, such as decanters and filters, accumulate high concentrations of iron (Fe) and manganese (Mn), which in many cases can be discharged into the environment without any treatment when maintenance is performed. Therefore, this paper evaluates the effectiveness of vertical subsurface wetlands for Fe and Mn removal from wastewater in drinking water treatment plants, taking a pilot scale wetland with an ascending gravel bed with two types of plants: C. esculenta and P. australis in El Hormiguero (Cali, Colombia), as an example. The pilot system had three upstream vertical wetlands, two of them planted and the third one without a plant used as a control. The wetlands were arranged in parallel and each formed by three gravel beds of different diameter. The results showed no significant difference for the percentage of removal in the three wetlands for turbidity (98 %), Fe (90 %), dissolved Fe (97 %) and Mn (98 %). The dissolved oxygen presented a significant difference between the planted wetlands and the control. C. esculenta had the highest concentration of Fe in the root with (103.5 ± 20.8) μg/g; while P australis had the highest average of Fe concentrations in leaves and stem with (45.7 ± 24) μg/g and (41.4 ± 9.1) μg/g, respectively. It is concluded that subsurface wetlands can be an interesting alternative for wastewater treatment in the maintenance of drinking water treatment plants. However, more research is needed for the use of vegetation or some technologies for the removal or reduction of the pollutant load in wetlands, since each drinking water treatment plant will require a treatment system for wastewater, which in turn requires a wastewater treatment system as well
Resumen El crecimiento de la población y la urbanización imponen una mayor presión al tratamiento de agua potable. Por otra parte, las diferentes unidades de tratamiento, como decantadores y filtros, acumulan altas concentraciones de hierro (Fe) y manganeso (Mn), las cuales, en muchos casos, son descargadas en el ambiente sin ningún tratamiento cuando se hace mantenimiento. Este artículo evalúa la efectividad de humedales subsuperficiales de flujo vertical para la remoción de Fe y Mn provenientes de agua residual en plantas de tratamiento de agua potable, tomando como ejemplo un humedal de flujo ascendente a escala piloto, con un lecho de grava y dos tipos de plantas: C. esculenta y P. australis en El Hormiguero (Cali, Colombia). El sistema piloto consistió en tres humedales verticales de flujo ascendente, dos de ellos plantados y el tercero sin plantas, como control. Los humedales se organizaron en paralelo, cada uno formado por tres lechos de grava de diferente diámetro. Los resultados mostraron que no hubo diferencia significativa en el porcentaje de remoción en los tres humedales para turbidez (98 %), Fe (90 %), Fe disuelto (97 %) y Mn (98 %). El oxígeno disuelto presentó una diferencia significativa entre los humedales plantados y el control. C. esculenta tuvo la concentración más alta de Fe en la raíz, con (103.5 ± 20.8) μg/g; mientras que P. australis tuvo el promedio más alto de concentraciones de Fe en hojas y tallos, con (45.7 ± 24) μg/g y (41.4 ± 9.1) μg/g, respectivamente. Se concluye que los humedales subsuperficiales pueden ser una alternativa interesante para el tratamiento de aguas residuales en el mantenimiento de plantas de tratamiento de agua potable. Sin embargo, se requiere más investigación sobre el uso de vegetación u otras tecnologías para la remoción o reducción de la carga contaminante en humedales, ya que cada planta de tratamiento de agua potable o su sistema de tratamiento de aguas residuales con humedales mantendrá el contaminante en el sistema.
Resumo O crescimento da população e da urbanização impõem uma maior pressão ao tratamento de água potável. Adicionalmente, as diferentes unidades de tratamento, como decantadores e filtros, acumulam altas concentrações de ferro (Fe) e manganês (Mn), as quais, em muitos casos, são liberadas no ambiente durante a manutenção, sem receber nenhum tipo de tratamento. Este artigo avaliou a eficácia de zonas úmidas subsuperficiais de fluxo vertical na remoção de Fe e Mn provenientes das águas residuais de estações de tratamento de água potável, usando como exemplo uma zona úmida a escala piloto com fluxo ascendente, leito de cascalho e dois tipos de plantas, C. esculenta e P. australis, localizada em El Hormiguero (Cali, Colombia). O sistema piloto usou três zonas úmidas verticais de fluxo ascendente, duas delas com plantas e a terceira sem plantas, como controle. As zonas húmidas foram organizadas em paralelo, cada uma sendo formada por três leitos de cascalho de diferente diâmetro. Os resultados mostraram que não houve diferença significativa na porcentagem de remoção das três zonas úmidas em termos de turbidez (98 %), Fe (90 %), Fe dissolvido (97 %) e Mn (98 %). O oxigênio dissolvido apresentou uma diferença significativa entre as zonas úmidas plantadas e a controle. C. esculenta teve a concentração mais alta de Fe na raiz, (103.5 ± 20.8) μg/g, em quanto P. au tralis teve a maior média de concentrações de Fe nas folhas e nos talos, (45.7 ± 24) μg/g e (41.4 ± 9.1) μg/g, respetivamente. Concluiuse que as zonas úmidas subsuperficiais podem ser uma alternativa interessante para o tratamento de águas residuais durante a manutenção de estações de tratamento de água potável. No entanto, mais pesquisa é necessária para determinar a importâncias do uso da vegetação ou outras tecnologias para a remoção ou diminuição da carga contaminante nas zonas úmidas, pois cada estação de tratamento de água potável ou sistema de tratamento de águas residuais com zonas úmidas irá manter oconaminante no sistema.
RESUMO
RESUMO O nitrogênio é um dos contaminantes mais importantes presentes nas águas residuais. As alternativas tecnológicas mais usuais para o tratamento de águas contendo esse composto lançam mão do ciclo bioquímico do nitrogênio, o qual se sustenta em dois processos, a nitrificação e a desnitrificação. Dentre os parâmetros que influenciam na remoção de nitrogênio, podemos citar a concentração de oxigênio dissolvido, relação carbono/nitrogênio, temperatura, pH entre outros. Este trabalho apresenta uma revisão sobre a remoção biológica de nitrogênio das águas e os principais parâmetros que influenciam na sua remoção, dando ênfase ao processo de nitrificação e desnitrificação simultânea.
ABSTRACT Nitrogen is one of the most important contaminants present in wastewater. The most common alternative technologies for the treatment of waters containing this compound lay hold of the biochemical cycle of nitrogen, which is based on two processes, nitrification and denitrification. Among the parameters that influence the removal of nitrogen, we can mention the concentration of dissolved oxygen, carbon/nitrogen ratio, temperature, pH, and other relationships. This paper presents an overview of the biological nitrogen removal of water and the main parameters that influence the removal, emphasizing the simultaneous nitrification and denitrification process.
RESUMO
A água é um reagente utilizado na maioria dos testes laboratoriais e por isso deve seguir um padrão de controle de qualidade rigoroso. O fornecimento urbano de água apresenta moléculas orgânicas, íons inorgânicos, partículas, coloides, gases, bactérias e seus produtos, que podem alterar os resultados dos exames laboratoriais e causar eventuais erros e falhas mecânicas em equipamentos analíticos. Para remover essas impurezas, é necessário recorrer a uma combinação de tecnologias de purificação. Há várias organizações que especificam normas sobre a água reagente, a fim de minimizar sua interferência nos ensaios laboratoriais. A maioria dos laboratórios utiliza as normas estabelecidas pelo Clinical and Laboratory Standards Institute (CLSI) que classifica a água em: clinical laboratory reagent water (CLRW), special reagent water (SRW) e instrumental feed water (IFW). O monitoramento da qualidade é realizado pela determinação de resistividade, condutividade, carbono orgânico total (TOC), controle microbiológico e endotoxinas. Os parâmetros são avaliados de acordo com a periodicidade estabelecida pela norma utilizada. Neste artigo, discutem-se a importância da água utilizada nos procedimentos laboratoriais, o controle da qualidade e as interferências nos ensaios laboratoriais.
Water is a reagent used in most laboratory tests and, therefore, must follow stringent quality control standards. The urban water supply has organic molecules, inorganic ions, particles, colloids, gases, bacteria and their products, which may alter laboratory test results and cause occasional errors and mechanical failures in diagnostic equipment. To remove these impurities, it is necessary to use a combination of purification technologies. There are several organizations that specify reagent water standards to minimize its interference in laboratory assays. Most laboratories set standards established by the Clinical and Laboratory Standards Institute (CLSI), which classifies the type of water as follows: clinical laboratory reagent water (CLRW), special reagent water (SRW) and instrumental feed water (IFW). The quality monitoring is performed by means of assessing the resistivity, conductivity, total organic carbon (TOC), microbial control and endotoxins. The parameters are evaluated in accordance with the frequency determined by the standard used. In this article we discuss the importance of water employed in laboratory procedures, its quality control and its interference in laboratory assays.