Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 431
Filtrar
1.
Phys Med Biol ; 69(15)2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-38959910

RESUMO

Objective.To develop and benchmark a novel 3D dose verification technique consisting of polymer gel dosimetry (PGD) with cone-beam-CT (CBCT) readout through a two-institution study. The technique has potential for wide and robust applicability through reliance on CBCT readout.Approach. Three treatment plans (3-field, TG119-C-shape spine, 4-target SRS) were created by two independent institutions (Institutions A and B). A Varian Truebeam linear accelerator was used to deliver the plans to NIPAM polymer gel dosimeters produced at both institutions using an identical approach. For readout, a slow CBCT scan mode was used to acquire pre- and post-irradiation images of the gel (1 mm slice thickness). Independent gel analysis tools were used to process the PGD images (A: VistaAce software, B: in-house MATLAB code). Comparing planned and measured doses, the analysis involved a combination of 1D line profiles, 2D contour plots, and 3D global gamma maps (criteria ranging between 2%1 mm and 5%2 mm, with a 10% dose threshold).Main results. For all gamma criteria tested, the 3D gamma pass rates were all above 90% for 3-field and 88% for the SRS plan. For the C-shape spine plan, we benchmarked our 2% 2 mm result against previously published work using film analysis (93.4%). For 2%2 mm, 99.4% (Institution A data), and 89.7% (Institution B data) were obtained based on VistaAce software analysis, 83.7% (Institution A data), and 82.9% (Institution B data) based on MATLAB.Significance. The benchmark data demonstrate that when two institutions follow the same rigorous procedures gamma passing rates up to 99%, for 2%2 mm criteria can be achieved for substantively different treatment plans. The use of different software and calibration techniques may have contributed to the variation in the 3D gamma results. By sharing the data across institutions, we observe the gamma passing rate is more consistent within each pipeline, indicating the need for standardized analysis methods.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Aceleradores de Partículas , Radiometria , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada de Feixe Cônico/métodos , Radiometria/métodos , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Imageamento Tridimensional/métodos , Polímeros/química
2.
Cancers (Basel) ; 16(11)2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38893241

RESUMO

Contrast-enhanced breast MRI has an established role in aiding in the detection, evaluation, and management of breast cancer. This article discusses MRI sequences, the clinical utility of MRI, and how MRI has been evaluated for use in breast radiotherapy treatment planning. We highlight the contribution of MRI in the decision-making regarding selecting appropriate candidates for breast conservation therapy and review the emerging role of MRI-guided breast radiotherapy.

3.
Biomed Pharmacother ; 175: 116668, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38701565

RESUMO

The combination of radiation treatment and chemotherapy is currently the standard for management of cancer patients. However, safe doses do not often provide effective therapy, then pre-treated patients are forced to repeat treatment with often already increased tumor resistance to drugs and irradiation. One of the solutions we suggest is to improve primary course of radiation treatment via enhancing radiosensitivity of tumors by magnetic-guided iron oxide nanoparticles (magnetite). We obtained spherical heparinized iron oxide nanoparticles (hIONPs, ∼20 nm), characterized it by TEM, Infrared spectroscopy and DLS. Then hIONPs cytotoxicity was assessed for colon cancer cells (XTT assay) and cellular uptake of nanoparticles was analyzed with X-ray fluorescence. Combination of ionizing radiation (IR) and hIONPs in vitro caused an increase of G2/M arrest of cell cycle, mitotic errors and decrease in survival (compared with samples exposed to IR and hIONPs separately). The promising results were shown for magnetic-guided hIONPs in CT26-grafted BALB/C mice: the combination of intravenously administrated hIONPs and IR showed 20,8% T/C ratio (related to non-treated mice), while single radiation had no shown significant decrease in tumor growth (72,4%). Non-guided by magnets hIONPs with IR showed 57,9% of T/C. This indicates that ultra-small size and biocompatible molecule are not the key to successful nano-drug design, in each case, delivery technologies need to be improved when transferred to in vivo model.


Assuntos
Neoplasias do Colo , Heparina , Nanopartículas Magnéticas de Óxido de Ferro , Camundongos Endogâmicos BALB C , Radiossensibilizantes , Animais , Neoplasias do Colo/tratamento farmacológico , Neoplasias do Colo/patologia , Neoplasias do Colo/radioterapia , Nanopartículas Magnéticas de Óxido de Ferro/química , Radiossensibilizantes/farmacologia , Radiossensibilizantes/química , Radiossensibilizantes/administração & dosagem , Humanos , Camundongos , Linhagem Celular Tumoral , Heparina/química , Heparina/farmacologia , Nanopartículas de Magnetita/química , Ensaios Antitumorais Modelo de Xenoenxerto , Sobrevivência Celular/efeitos dos fármacos
4.
Front Oncol ; 14: 1365197, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38590652

RESUMO

Introduction: Radiation treatment has replaced enucleation as an organ-preservation treatment for patients with uveal melanoma (UM). We developed a novel non-invasive, frameless LINAC based solution for fractionated stereotactic radiosurgery (fSRS) treatment. Methods: We designed and constructed the a stereotactic ocular localization box that can be attached and indexed to a stereotactic LINAC tabletop. It contains adjustable LED lights as a gaze focus point and CCD camera for monitoring of the patient's eye position. The device also has 6 infrared spheres compatible with the ExacTRAC IGRT system. Treatment plans were developed using iPLAN Dose version 4.5, with conformal dynamic arcs and 6MV photon beam in flattening filter free mode, dosed to 50Gy in 5 fractions. During treatment, patients were instructed to stare at the light when a radiation beam is prepared and ready for delivery. Eye movement was tracked throughout treatment. Residual setup errors were recorded for evaluation. Results: The stereotactic ocular localization box was 3D-printed with polylactic acid material and attached to the stereotactic LINAC tabletop. 10 patients were treated to evaluate the feasibility, tolerability and setup accuracy. Median treatment time for each arc is 17.3 ± 2.4 seconds (range: 13.8-23.4). After ExacTRAC setup, the residual setup errors are -0.1 ± 0.3 mm laterally, -0.1 ± 0.3 mm longitudinally, and 0 ± 0.2 mm vertically. The residue rotational errors are -0.1 ± 0.3 degree pitch, 0.1 ± 0.2 degree roll, and 0 ± 0.2 degree couch rotation. All patients received treatment successfully. Conclusion: We successfully developed a novel non-invasive frameless mask-based LINAC solution for SRS for uveal melanoma, or other ocular tumors. It is well tolerated with high set up accuracy. Future directions for this localization box would include a multi-center trial to assess the efficacy and reproducibility in the fabrication and execution of such a solution for UM therapy.

5.
Oncol Res Treat ; 47(6): 287-295, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38432228

RESUMO

INTRODUCTION: The management of metastatic spinal cord compression (mSCC) is a demanding task. The main challenges of mSCC include various manifestations and unpredictable outcomes with indiscriminate treatment recommendations. Because of attendant urgency with potentially devastating health consequences, the SCC is an emotionally disturbing experience whose management could take an impulsive rather than rational approach. The treatment strategy is particularly problematic when mSCC is caused by a malignant lymphoma with its protean attributes. CASE REPORT: A 68-year-old female presented with generalized body pain and weight loss. Imaging studies revealed a vast bulk of the disease involving lymph nodes, spleen, visceral organs, musculature, marrow, and bones including vertebrae with extension into the spinal canal. A biopsy of the chest wall mass showed high-grade diffuse large B-cell lymphoma. A magnetic resonance imaging (MRI) of the spine demonstrated diffuse marrow replacement by the tumor of the thoracic and lumbar spine with compression of the cord. The prompt treatment with corticosteroids and immunochemotherapy (ICT) was recommended, but the patient elected to seek a second opinion. After two doses of radiation therapy, the patient's general condition rapidly deteriorated and she was hospitalized for systemic ICT. Despite the treatment, her condition continued to deteriorate, and she died 3 weeks after the presentation. CONCLUSION: The presented case demonstrates some hitherto unaddressed challenges in evaluation and treatment of mSCC caused by aggressive non-Hodgkin lymphoma (LSSC). The case scrutinizes the role of MRI in uncommon clinical situations. The case has also exposed some ethical issues associated with the proper management of LSCC.


Assuntos
Compressão da Medula Espinal , Humanos , Compressão da Medula Espinal/etiologia , Compressão da Medula Espinal/terapia , Feminino , Idoso , Evolução Fatal , Linfoma Difuso de Grandes Células B/terapia , Linfoma Difuso de Grandes Células B/patologia , Linfoma de Células B/terapia , Linfoma de Células B/complicações , Linfoma de Células B/patologia , Neoplasias da Coluna Vertebral/secundário , Neoplasias da Coluna Vertebral/complicações , Neoplasias da Coluna Vertebral/terapia , Imageamento por Ressonância Magnética
6.
Materials (Basel) ; 17(5)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38473623

RESUMO

Glioblastoma multiforme (GBM) is a glioma and the most aggressive type of brain tumor with a dismal average survival time, despite the standard of care. One promising alternative therapy is boron neutron capture therapy (BNCT), which is a noninvasive therapy for treating locally invasive malignant tumors, such as glioma. BNCT involves boron-10 isotope capturing neutrons to form boron-11, which then releases radiation directly into tumor cells with minimal damage to healthy tissues. This therapy lacks clinically approved targeted blood-brain-barrier-permeating delivery vehicles for the central nervous system (CNS) entry of therapeutic boron-10. Gold nanoparticles (GNPs) are selective and effective drug-delivery vehicles because of their desirable properties, facile synthesis, and biocompatibility. This review discusses biomedical/therapeutic applications of GNPs as a drug delivery vehicle, with an emphasis on their potential for carrying therapeutic drugs, imaging agents, and GBM-targeting antibodies/peptides for treating glioma. The constraints of GNP therapeutic efficacy and biosafety are discussed.

7.
Strahlenther Onkol ; 200(6): 507-511, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38530418

RESUMO

BACKGROUND: Multimodal breast cancer treatment may cause side effects reflected in patient-reported outcomes and/or symptom scores at the time of treatment planning for adjuvant radiotherapy. In our department, all patients have been assessed with the Edmonton Symptom Assessment System (ESAS; a questionnaire addressing 11 major symptoms and wellbeing on a numeric scale of 0-10) at the time of treatment planning since 2016. In this study, we analyzed ESAS symptom severity before locoregional radiotherapy. PATIENTS AND METHODS: Retrospective review of 132 patients treated between 2016 and 2021 (all comers in breast-conserving or post-mastectomy settings, different radiotherapy fractionations) was performed. All ESAS items and the ESAS point sum were analyzed to identify subgroups with higher symptom burden and thus need for additional care measures. RESULTS: The biggest patient-reported issues were fatigue, pain, and sleep problems. Patients with triple negative breast cancer reported a higher symptom burden (mean 30 versus 20, p = 0.038). Patients assigned to adjuvant endocrine therapy had the lowest point sum (mean 18), followed by those on Her-2-targeting agents without chemotherapy (mean 19), those on chemotherapy with or without other drugs (mean 26), and those without systemic therapy (mean 41), p = 0.007. Those with pathologic complete response after neoadjuvant treatment had significantly lower anxiety scores (mean 0.7 versus 1.8, p = 0.03) and a trend towards lower depression scores, p = 0.09. CONCLUSION: Different surgical strategies, age, and body mass index did not impact on ESAS scores, while the type of adjuvant systemic therapy did. The effect of previous neoadjuvant treatment and unfavorable tumor biology (triple negative) emerged as important factors associated with symptom burden, albeit in different domains. ESAS data may facilitate identification of patients who should be considered for additional supportive measures to alleviate specific symptoms.


Assuntos
Medidas de Resultados Relatados pelo Paciente , Neoplasias de Mama Triplo Negativas , Humanos , Feminino , Pessoa de Meia-Idade , Radioterapia Adjuvante , Idoso , Estudos Retrospectivos , Adulto , Neoplasias de Mama Triplo Negativas/radioterapia , Neoplasias de Mama Triplo Negativas/patologia , Avaliação de Sintomas , Fadiga/etiologia , Transtornos do Sono-Vigília/etiologia , Quimioterapia Adjuvante , Mastectomia , Terapia Combinada , Carga de Sintomas
8.
Cancers (Basel) ; 16(2)2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38275880

RESUMO

Head and neck squamous cell carcinoma (HNSCC) exhibits considerable variability in patient outcome. It has been reported that SOX2 plays a role in proliferation, tumor growth, drug resistance, and metastasis in a variety of cancer types. Additionally, SOX9 has been implicated in immune tolerance and treatment failures. SOX2 and SOX9 induce treatment failure by a molecular mechanism that has not yet been elucidated. This study explores the inverse association of SOX2/SOX9 and their distinct expression in tumors, influencing the tumor microenvironment and radiotherapy responses. Through public RNA sequencing data, human biopsy samples, and knockdown cellular models, we explored the effects of inverted SOX2 and SOX9 expression. We found that patients expressing SOX2LowSOX9High showed decreased survival compared to SOX2HighSOX9Low. A survival analysis of patients stratified by radiotherapy and human papillomavirus brings additional clinical relevance. We identified a gene set signature comprising newly discovered candidate genes resulting from inverted SOX2/SOX9 expression. Moreover, the TGF-ß pathway emerges as a significant predicted contributor to the overexpression of these candidate genes. In vitro findings reveal that silencing SOX2 enhances tumor radioresistance, while SOX9 silencing enhances radiosensitivity. These discoveries lay the groundwork for further studies on the therapeutic potential of transcription factors in optimizing HNSCC treatment.

9.
Med Phys ; 51(3): 2108-2118, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37633837

RESUMO

PURPOSE: The rising promise in the utility of advanced multi-parametric magnetic resonance (MR) imaging in radiotherapy (RT) treatment planning creates a necessity for testing and enhancing the accuracy of quantitative imaging analysis. Standardizing the analysis of diffusion weighted imaging (DWI) and diffusion tensor imaging (DTI) to generate meaningful and reproducible apparent diffusion coefficient (ADC) and fractional anisotropy (FA) lays the requisite needed for clinical integration. The aim of the demonstrated work is to benchmark the generation of the ADC and FA parametric map analyses using integrated tools in a commercial treatment planning system against the currently used ones. METHODS: Three software packages were used for generating ADC and FA maps in this study; one tool was developed within a commercial treatment planning system, another by the Functional Magnetic Resonance Imaging of the Brain (FMRIB) Software Library FSL (Analysis Group, FMRIB, Oxford, United Kingdom), and an in-house tool developed at the M.D. Anderson Cancer Center. The ADC and FA maps generated by all three packages for 35 subjects were subtracted from one another, and the standard deviation of the images' differences was used to compare the reproducibility. The reproducibility of the ADC maps was compared with the Quantitative Imaging Biomarkers Alliance (QIBA) protocol, while that of the FA maps was compared to data in published literature. RESULTS: Results show that the discrepancies between the ADC maps calculated for each patient using the three different software algorithms are less than 2% which meets the 3.6% recommended QIBA requirement. Except for a small number of isolated points, the majority of differences in FA maps for each patient produced by the three methods did not exceed 0.02 which is 10 times lower than the differences seen in healthy gray and white matter. The results were also compared to the maps generated by existing MR Imaging consoles and showed that the robustness of console generated ADC and FA maps is largely dependent on the correct application of scaling factors, that only if correctly placed; the differences between the three tested methods and the console generated values were within the recommended QIBA guidelines. CONCLUSIONS: Cross-comparison difference maps demonstrated that quantitative reproducibility of ADC and FA metrics generated using our tested commercial treatment planning system were comparable to in-house and established tools as benchmarks. This integrated approach facilitates the clinical utility of diffusion imaging in radiation treatment planning workflow.


Assuntos
Benchmarking , Imagem de Tensor de Difusão , Humanos , Imagem de Tensor de Difusão/métodos , Reprodutibilidade dos Testes , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética , Anisotropia
10.
Strahlenther Onkol ; 200(2): 123-127, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37264179

RESUMO

PURPOSE: The purpose of this study was to investigate the feasibility and effectiveness of high-dose planned adaptive intensity-modulated radiation therapy (IMRT) with helical tomotherapy (HT) for cutaneous angiosarcoma (cAS) of the scalp. METHODS: This retrospective cross-sectional included a total of 12 consecutive patients with cAS of the scalp who underwent high-dose planned adaptive IMRT with HT. Prescribed doses were 72.5-74 Gy in 35-37 fractions for the gross tumor volume plus a 1-2 mm margin (PTV1), 58-60 Gy in 29-30 fractions for the clinical target volume plus a 2-3 mm margin (PTV2), and 46 Gy in 23 fractions for the clinical target volume plus a 5-15 mm margin (PTV3) over periods of 7.5, 6 and 4.5 weeks, respectively. RESULTS: The estimated 1­year and 2­year overall survival rate were 65.6% and 27.3%, respectively, and the local progression-free survival at 2 years was 74.1%. All local recurrences were either in or marginal to the PTV2 or PTV3. No local recurrence was observed in the PTV1. All patients tolerated the treatment without grade 3 or higher adverse events during the radiotherapy period. No late adverse events were observed during the follow-up period. CONCLUSION: Planned adaptive high-dose IMRT with HT has the potential to improve local control rate without increasing adverse events.


Assuntos
Hemangiossarcoma , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Hemangiossarcoma/radioterapia , Planejamento da Radioterapia Assistida por Computador , Couro Cabeludo , Estudos Transversais , Estudos Retrospectivos
11.
Med Phys ; 51(4): 3053-3066, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38043086

RESUMO

BACKGROUND: Online dose calculations before the delivery of radiation treatments have applications in dose delivery verification, online adaptation of treatment plans, and simulation-free treatment planning. While dose calculations by directly utilizing CBCT images are desired, dosimetric accuracy can be compromised due to relatively lower HU accuracy in CBCT images. PURPOSE: In this work, we propose a novel CBCT imaging pipeline to enhance the accuracy of CBCT-based dose calculations in the pelvis region. Our approach aims to improve the HU accuracy in CBCT images, thereby improving the overall accuracy of CBCT-based dose calculations prior to radiation treatment delivery. METHODS: An in-house developed quantitative CBCT pipeline was implemented to address the CBCT raw data contamination problem. The pipeline combines algorithmic data correction strategies and 2D antiscatter grid-based scatter rejection to achieve high CT number accuracy. To evaluate the effect of the quantitative CBCT pipeline on CBCT-based dose calculations, phantoms mimicking pelvis anatomy were scanned using a linac-mounted CBCT system, and a gold standard multidetector CT used for treatment planning (pCT). A total of 20 intensity-modulated treatment plans were generated for five targets, using 6 and 10 MV flattening filter-free beams, and utilizing small and large pelvis phantom images. For each treatment plan, four different dose calculations were performed using pCT images and three CBCT imaging configurations: quantitative CBCT, clinical CBCT protocol, and a high-performance 1D antiscatter grid (1D ASG). Subsequently, dosimetric accuracy was evaluated for both targets and organs at risk as a function of patient size, target location, beam energy, and CBCT imaging configuration. RESULTS: When compared to the gold-standard pCT, dosimetric errors in quantitative CBCT-based dose calculations were not significant across all phantom sizes, beam energies, and treatment sites. The largest error observed was 0.6% among all dose volume histogram metrics and evaluated dose calculations. In contrast, dosimetric errors reached up to 7% and 97% in clinical CBCT and high-performance ASG CBCT-based treatment plans, respectively. The largest dosimetric errors were observed in bony targets in the large phantom treated with 6 MV beams. The trends of dosimetric errors in organs at risk were similar to those observed in the targets. CONCLUSIONS: The proposed quantitative CBCT pipeline has the potential to provide comparable dose calculation accuracy to the gold-standard planning CT in photon radiation therapy for the abdomen and pelvis. These robust dose calculations could eliminate the need for density overrides in CBCT images and enable direct utilization of CBCT images for dose delivery monitoring or online treatment plan adaptations before the delivery of radiation treatments.


Assuntos
Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Pelve/diagnóstico por imagem , Dosagem Radioterapêutica , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Abdome
12.
J Med Radiat Sci ; 71(1): 91-99, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38131264

RESUMO

INTRODUCTION: Patients undergoing radiation therapy have a diverse range of information needs, however, there is a lack of data specific to the needs of New Zealand patients. This cross-sectional survey captured New Zealand cancer patients' preferences for radiation treatment information. Preferences were assessed regarding the scope of information needs and the satisfaction with which these needs were being met. METHODS: A custom survey was offered to 275 eligible patients undergoing radiation treatment at six of 10 departments across New Zealand over a 2-day period. The survey captured patient demographics as well as information needs and satisfaction across five distinct domains using Likert scales and one free-text question. Responses were analysed using descriptive statistics and directed content analysis. RESULTS: Over 80% of participants rated all information domains as extremely or very important. Over 90% of participants were extremely satisfied or very well satisfied in four of the five domains. Information on what happens after radiation treatment had the lowest satisfaction at 78%. No demographic subcategories were clearly associated with differences in information needs or satisfaction. 59% of participants indicated their willingness to engage in online education. The qualitative analysis strongly corroborated the quantitative results. CONCLUSION: The New Zealand cancer patients surveyed in this study demonstrated high levels of importance and satisfaction with the information provided during radiation treatment. Information on what happens after completing radiation treatment had the lowest satisfaction. These findings support further exploration of New Zealand cancer patients' information needs following radiation treatment as well as strategies to address them.


Assuntos
Neoplasias , Preferência do Paciente , Humanos , Nova Zelândia , Estudos Transversais , Inquéritos e Questionários , Neoplasias/radioterapia
13.
J Appl Clin Med Phys ; 24(12): e14205, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37975638

RESUMO

In magnetic resonance imaging (MRI), it is necessary to reduce image distortion as much as possible because it suppresses the increase in the planning target volume. This study investigated the relationship between imaging parameters and image distortion when using G-frames. The images were obtained using a 1.5-T MRI system with a 09-101 Pro-MRI phantom. Image distortion was measured by changing the RF pulse mode, gradient mode, asymmetric echo, and bandwidth (BW). The image distortion was increased in the high RF mode than in the Normal mode. The image distortion increased in the following order: Whisper â‰¦ Normal < Fast in the different gradient modes. The image distortion increased in the following order: Without â‰¦ Weak < Strong in the different asymmetric echo modes. The image distortion increased in the following order: 300 Hz/pixel > 670 Hz/pixel â‰§ REF (150 Hz/pixel) in the different Bw. The relationship between parameters and image distortion was clarified in this study when G-frames were used for gamma knife therapy. There is had relationship between the parameters causing variation in the gradient magnetic field and image distortion. Therefore, these parameters should be adjusted to minimize distortion.


Assuntos
Imageamento por Ressonância Magnética , Radiocirurgia , Humanos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos
14.
Cancers (Basel) ; 15(22)2023 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-38001574

RESUMO

Radiation treatment (RT) is a mainstay treatment for many types of cancer. Recommendations for RT and the radiation plan are individualized to each patient, taking into consideration the patient's tumor pathology, staging, anatomy, and other clinical characteristics. Information on germline mutations and somatic tumor mutations is at present rarely used to guide specific clinical decisions in RT. Many genes, such as ATM, and BRCA1/2, have been identified in the laboratory to confer radiation sensitivity. However, our understanding of the clinical significance of mutations in these genes remains limited and, as individual mutations in such genes can be rare, their impact on tumor response and toxicity remains unclear. Current guidelines, including those from the National Comprehensive Cancer Network (NCCN), provide limited guidance on how genetic results should be integrated into RT recommendations. With an increasing understanding of the molecular underpinning of radiation response, genomically-guided RT can inform decisions surrounding RT dose, volume, concurrent therapies, and even omission to further improve oncologic outcomes and reduce risks of toxicities. Here, we review existing evidence from laboratory, pre-clinical, and clinical studies with regard to how genetic alterations may affect radiosensitivity. We also summarize recent data from clinical trials and explore potential future directions to utilize genetic data to support clinical decision-making in developing a pathway toward personalized RT.

15.
Cancers (Basel) ; 15(21)2023 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-37958447

RESUMO

A 1.5T MRI combined with a linear accelerator (Unity®, Elekta; Stockholm, Sweden) is a device that shows promise in MRI-guided stereotactic body radiation treatment (SBRT). Previous studies utilized the manufacturer's pre-set MRI sequences (i.e., T2 Weighted (T2W)), which limited the visualization of pancreatic and intra-abdominal tumors and organs at risk (OAR). Here, a T1 Weighted (T1W) sequence was utilized to improve the visualization of tumors and OAR for online adapted-to-position (ATP) and adapted-to-shape (ATS) during MRI-guided SBRT. Twenty-six patients, 19 with pancreatic and 7 with intra-abdominal cancers, underwent CT and MRI simulations for SBRT planning before being treated with multi-fractionated MRI-guided SBRT. The boundary of tumors and OAR was more clearly seen on T1W image sets, resulting in fast and accurate contouring during online ATP/ATS planning. Plan quality in 26 patients was dependent on OAR proximity to the target tumor and achieved 96 ± 5% and 92 ± 9% in gross tumor volume D90% and planning target volume D90%. We utilized T1W imaging (about 120 s) to shorten imaging time by 67% compared to T2W imaging (about 360 s) and improve tumor visualization, minimizing target/OAR delineation uncertainty and the treatment margin for sparing OAR. The average time-consumption of MRI-guided SBRT for the first 21 patients was 55 ± 15 min for ATP and 79 ± 20 min for ATS.

16.
Front Oncol ; 13: 1252014, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37909014

RESUMO

Radiation treatment is one of the most frequently used therapies in patients with cancer, employed in approximately half of all patients. However, the use of radiation therapy is limited by acute or chronic adverse effects and the failure to consider the tumor microenvironment. Blood vessels substantially contribute to radiation responses in both normal and tumor tissues. The present study employed a three-dimensional (3D) microvasculature-on-a-chip that mimics physiological blood vessels to determine the effect of radiation on blood vessels. This model represents radiation-induced pathophysiological effects on blood vessels in terms of cellular damage and structural and functional changes. DNA double-strand breaks (DSBs), apoptosis, and cell viability indicate cellular damage. Radiation-induced damage leads to a reduction in vascular structures, such as vascular area, branch length, branch number, junction number, and branch diameter; this phenomenon occurs in the mature vascular network and during neovascularization. Additionally, vasculature regression was demonstrated by staining the basement membrane and microfilaments. Radiation exposure could increase the blockage and permeability of the vascular network, indicating that radiation alters the function of blood vessels. Radiation suppressed blood vessel recovery and induced a loss of angiogenic ability, resulting in a network of irradiated vessels that failed to recover, deteriorating gradually. These findings demonstrate that this model is valuable for assessing radiation-induced vascular dysfunction and acute and chronic effects and can potentially improve radiotherapy efficiency.

17.
Curr Issues Mol Biol ; 45(10): 8152-8172, 2023 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-37886958

RESUMO

The spatial organization of euchromatin (EC) and heterochromatin (HC) appears as a cell-type specific network, which seems to have an impact on gene regulation and cell fate. The spatial organization of cohesin should thus also be characteristic for a cell type since it is involved in a TAD (topologically associating domain) formation, and thus in gene regulation or DNA repair processes. Based on the previous hypotheses and results on the general importance of heterochromatin organization on genome functions in particular, the configurations of these organizational units (EC represented by H3K4me3-positive regions, HC represented by H3K9me3-positive regions, cohesins) are investigated in the cell nuclei of different cancer and non-cancerous cell types and under different anti-cancer treatments. Confocal microscopic images of the model cell systems were used and analyzed using analytical processes of quantification created in Fiji, an imaging tool box well established in different fields of science. Human fibroblasts, breast cancer and glioblastoma cells as well as murine embryonal terato-carcinoma cells were used as these cell models and compared according to the different parameters of spatial arrangements. In addition, proliferating, quiescent and from the quiescent state reactivated fibroblasts were analyzed. In some selected cases, the cells were treated with X-rays or azacitidine. Heterogeneous results were obtained by the analyses of the configurations of the three different organizational units: granulation and a loss of H3K4me3-positive regions (EC) occurred after irradiation with 4 Gy or azacitidine treatment. While fibroblasts responded to irradiation with an increase in cohesin and granulation, in breast cancer cells, it resulted in decreases in cohesin and changes in granulation. H3K9me3-positive regions (HC) in fibroblasts experienced increased granulation, whereas in breast cancer cells, the amount of such regions increased. After azacitidine treatment, murine stem cells showed losses of cohesin and granulation and an increase in the granulation of H3K9me3-positive regions. Fibroblasts that were irradiated with 2 Gy only showed irregularities in structural amounts and granulation. Quiescent fibroblasts contained less euchromatin-related H3K4me3-positive signals and cohesin levels as well as higher heterochromatin-related H3K9me3-positive signals than non-quiescent ones. In general, fibroblasts responded more intensely to X-ray irradiation than breast cancer cells. The results indicate the usefulness of model cell systems and show that, in general, characteristic differences initially existing in chromatin and cohesin organizations result in specific responses to anti-cancer treatment.

18.
Cancers (Basel) ; 15(15)2023 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-37568773

RESUMO

Glioblastoma (GBM) has a poor survival rate even with aggressive surgery, concomitant radiation therapy (RT), and adjuvant chemotherapy. Standard-of-care RT involves irradiating a lower dose to the hyperintense lesion in T2-weighted fluid-attenuated inversion recovery MRI (T2w/FLAIR) and a higher dose to the enhancing tumor on contrast-enhanced, T1-weighted MRI (CE-T1w). While there have been several attempts to segment pre-surgical brain tumors, there have been minimal efforts to segment post-surgical tumors, which are complicated by a resection cavity and postoperative blood products, and tools are needed to assist physicians in generating treatment contours and assessing treated patients on follow up. This report is one of the first to train and test multiple deep learning models for the purpose of post-surgical brain tumor segmentation for RT planning and longitudinal tracking. Post-surgical FLAIR and CE-T1w MRIs, as well as their corresponding RT targets (GTV1 and GTV2, respectively) from 225 GBM patients treated with standard RT were trained on multiple deep learning models including: Unet, ResUnet, Swin-Unet, 3D Unet, and Swin-UNETR. These models were tested on an independent dataset of 30 GBM patients with the Dice metric used to evaluate segmentation accuracy. Finally, the best-performing segmentation model was integrated into our longitudinal tracking web application to assign automated structured reporting scores using change in percent cutoffs of lesion volume. The 3D Unet was our best-performing model with mean Dice scores of 0.72 for GTV1 and 0.73 for GTV2 with a standard deviation of 0.17 for both in the test dataset. We have successfully developed a lightweight post-surgical segmentation model for RT planning and longitudinal tracking.

19.
Radiat Environ Biophys ; 62(3): 357-369, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37452828

RESUMO

The synergy of superparamagnetic iron oxide nanoparticles (SPIONs) and ionizing radiation (IR), attributed to reactive oxygen species (ROS) and DNA double-strand breaks (DSBs) increase, was widely investigated in different cancers, but scarcely in melanoma. Herein, SPIONs were evaluated as radiosensitizers in A-375 human melanoma cells. Moreover, the effect of the combined treatment of SPIONs and gamma irradiation (SPIONs-IR) was assessed at the DNA level, where DSBs induction and their repair capacity were studied. SPIONs were synthesized, stabilized by poly(ethylene glycol) methyl ether and physicochemically characterized by high resolution-transmission electron microscopy (HR-TEM), X-ray diffraction and magnetometry and dynamic light scattering. The obtained nanoparticles showing superparamagnetic behavior and low dispersion in shape and sizes were tested in A-375 cells. The intracellular internalization of SPIONs was verified by HR-TEM and quantified by inductively coupled plasma atomic emission spectroscopy. Cells treated with SPIONs exhibited high ROS levels without associated cytotoxicity. Next, a significant radiosensitization in SPIONs-IR vs. control (IR) cells was demonstrated at 1 Gy of gamma radiation. Furthermore, a decreased DSBs repair capacity in SPIONs-IR vs. IR-treated cells was evidenced by the size increase of persistent phosphorylated H2AX foci at 24 h post-irradiation. In conclusion, these nanoparticles show the potential to radiosensitize melanoma cells by the induction of unrepairable DNA damage.


Assuntos
Dano ao DNA , Melanoma , Humanos , Espécies Reativas de Oxigênio , Nanopartículas Magnéticas de Óxido de Ferro , Melanoma/radioterapia , Quebras de DNA de Cadeia Dupla
20.
Clin Transl Radiat Oncol ; 41: 100651, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37388711

RESUMO

Background: Whole-breast irradiation (WBI) after breast conserving surgery (BCS) is indicated to improve loco-regional control and survival. Former studies showed that addition of tumor bed boost in all age groups significantly improved local control although no apparent impact on overall survival but with an increased risk of worse cosmetic outcome. Even though shortened regimens in 3 weeks are considered the standard, recent studies have shown the non-inferiority of a treatment regimen of 5 fractions in one-week in both locoregional control and toxicity profile, although simultaneous integrated boost (SIB) in this setting has been scarcely studied. Materials and Methods: From March-2020 to March-2022, 383 patients with early breast cancer diagnosis and a median age of 56 years-old (range 30-99)were included in a prospective registry of ultra-hypofractionated WBI up to a total dose of 26 Gy in 5.2 Gy/fraction with a SIB of 29 Gy in 5.8 Gy/fraction in 272 patients (71%), 30-31 Gy in 6-6.2 Gy/fraction in 111 patients (29%) with close/focally affected margins. Radiation treatment was delivered by conformal 3-D technique in 366 patients (95%), VMAT in 16patients (4%) and conformal 3-D with deep inspiration breath hold (DIBH) in 4patients (1%). Ninety-three per cent of patients received endocrine therapy and 43% systemic or targeted chemotherapy. Development of acute skin complications was retrospectively reviewed. Results: With a median follow-up of 18 months (range 7-31), all patients are alive without evidence of local, regional or distant relapse. Acute tolerance was acceptable, with null o mild toxicity: 182 (48%) and 15 (4%) patients developed skin toxicity grade 1 and 2 respectively; 9 (2%) and 2 (0.5%) patients breast edema grade 1and 2 respectively. No other acute toxicities were observed. We also evaluated development of early delayed complications and observed grade 1 breast edema in 6 patients (2%); grade 1 hyperpigmentation in 20 patients (5%); and grade 1 and 2 breast induration underneath boost region in 10(3%) and 2 patients (0.5%) respectively. We found a statistically significant correlation between the median PTVWBI and presence of skin toxicity (p = 0.028) as well as a significant correlation between late hyperpigmentation with the median PTVBOOST (p = 0.007) and the ratio PTVBOOST/PTVWBI (p = 0.042). Conclusion: Ultra-hypofractionated WBI + SIB in 5 fractions over one-week is feasible and well tolerated, although longer follow-up is necessary to confirm these results.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...