Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Rev. colomb. anestesiol ; 51(4)dic. 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1535702

RESUMO

Introduction Anesthetists play an important role during interventional radiology procedures. Like the main operator, anesthetists may also be subject to significant radiation levels in the fluoroscopy suite. Due to its complexity, hepatic chemoembolization procedures demand high fluoroscopic times and digital subtraction angiography images, exposing patients and medical staff to high radiation doses. Objective To assess and quantify the radiation to which one anesthetist was exposed over the course of seven consecutive hepatic chemoembolization procedures, and compare it to the exposure received by the main operator. Methods Medical staff dosimetry was evaluated during seven consecutive hepatic chemoembolization procedures conducted in a private hospital in Recife (Brazil), using thermoluminiscent dosimeters placed in regions of the head and torso. Results For the seven procedures evaluated in this study, the anesthetist received, on average, absorbed doses to the glabella, left eyebrow, right eyebrow and effective dose of 142.4 ± 72 µSv, 117.3 ± 66 µSv, 137.8 ± 71 µSv and 12.4 ± 8.4 µSv, respectively. Conclusions In some cases, ocular dose and effective dose received by the anesthetist may be 4 and 4.7 times greater, respectively, when compared to the main operator. According to the results of this study, the current occupational annual dose limit to the lens of the eye of 20 mSv can be exceeded with only two hepatic chemoembolization procedures per week if adequate radiation protection conditions are not guaranteed.


Introducción El anestesiólogo desempeña un papel importante durante los procedimientos de radiología intervencionista. Al igual que el operador principal, el anestesiólogo también puede estar expuesto a niveles significativos de radiación en la sala de fluoroscopía. Debido a su complejidad, durante los procedimientos de quimioembolización hepática se deben utilizar imágenes de fluoroscopía y angiografía de sustracción digital por períodos prolongados, exponiendo a los pacientes y al personal médico a dosis elevadas de radiación. Objetivo Evaluar y cuantificar la radiación a la cual se expuso un anestesiólogo durante el transcurso de siete procedimientos consecutivos de quimioembolización hepática, y comparar con la exposición recibida por el operador principal. Métodos Evaluación de la dosimetría ocupacional durante siete procedimientos consecutivos de quimioembolización hepática realizados en un hospital privado de Recife (Brasil) por medio de dosímetros termoluminiscentes ubicados en regiones de la cabeza y el torso. Resultados Para los siete procedimientos evaluados en este estudio, el anestesiólogo recibió, en promedio, dosis absorbidas en el entrecejo, la ceja izquierda, la ceja derecha y dosis efectivas de 142,4 ± 72 µSv, 117,3 ± 66 µSv, 137,8 ± 71 µSv y 12,4 ± 8,4 µSv, respectivamente. Conclusiones En algunos casos, la dosis ocular y la dosis efectiva que recibe el anestesiólogo puede ser, respectivamente, entre 4 y 4,7 veces más alta que la que recibe el operador principal. De acuerdo con los resultados de este estudio, el límite ocupacional anual de dosis en cristalino (20 mSv) se puede superar con apenas dos procedimientos de quimioembolización hepática a la semana en caso de no garantizarse las condiciones adecuadas de protección contra la radiación.

2.
Rev. gastroenterol. Perú ; 43(4)oct. 2023.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1536364

RESUMO

La endoscopía digestiva ha evolucionado de una técnica puramente diagnóstica a un procedimiento terapéutico. Esto es posible en muchos casos gracias al uso de fluoroscopía, lo cual conlleva la exposición a radiaciones ionizantes tanto de los pacientes como del personal actuante. La colangiopancreatografía retrógrada endoscópica (CPRE), que requiere necesariamente de fluoroscopia, es catalogada por la Food and Drug Administration como un examen con potencial riesgo de desencadenar lesiones inducidas por radiación. El presente artículo de revisión repasa los efectos biológicos de las radiaciones, los tipos de equipos radiológicos utilizados en CPRE, así como las magnitudes y unidades dosimétricas, para finalmente abordar los elementos de radio protección en la sala de endoscopia. El objetivo es brindar al lector la informacion para poder realizar estos procedimientos con la mayor seguridad radiológica tanto para los pacientes como para el personal ocupacionalmente expuesto.


Endoscopy has evolved from a purely diagnostic technique to a therapeutic procedure. This is possible in many cases thanks to the use of fluoroscopy, which entails exposure to ionizing radiation for both patients and the personnel involved. Endoscopic retrograde cholangiopancreatography (ERCP), which necessarily requires fluoroscopy, is classified by the Food and Drug Administration as an examination with a potential risk of triggering radiation induced injuries. This article reviews the biological effects of radiation, the types of radiological equipment used in ERCP, as well as the magnitudes and dosimetric units, to finally address the radio protection elements in the endoscopy room. The objective is to provide the reader with the information to be able to perform these procedures with the greatest radiological safety for both patients and occupationally exposed personnel.

3.
Artigo em Inglês | MEDLINE | ID: mdl-34425970

RESUMO

Liver radioembolization is an emerging treatment against liver primary and secondary tumours. The whole procedure of radioembolization involves different health care specialists with different expertise. During the fractionation and infusion phases, the personnel manipulates high activities of 90Y. In our centre, the number of radioembolization treatments per year is increasing; the aim of this study is to monitor the dose to the operators and to estimate the radiological risk for the operators involved in the RE. At present, two medical devices are approved: Sir-Sphere® and Therasphere™, both loaded with 90Y. The dosimeters used were TLDs placed over the fingertips, for a total of 4 dosimeters for each phase; the selected dose descriptor was Hp0.07. The study concerned 17 patients affected by malignant hepatic lesions, treated from September 2017 to March 2018. We performed 27 procedures: 10 fractionations (with Sir-Sphere®) and 17 infusions to the patients (10 with Sir-Spheres®, 7 with Theraspheres™). For fractionation phase, the average activity of each preparation was 3.34 GBq, the average value of Hp0.07 was 0.50mSv. For infusion phase, the average activity was 1.51 GBq for Sir-Sphere® and 2.10 GBq for Theraspheres™, the average value of Hp0.07 was 0.10mSv. No significant differences were found between senior (Hp0.07 = 0.08mSv) and young operators (Hp0.07 = 0.09mSv), respectively. Similarly, no significant differences were found between the right and left hand, with the same average value of Hp0.07 (0.01mSv). In conclusion, the results are encouraging, since fingertips reported doses very low. The handling of 90Y microspheres and the radioembolization procedure can be carried out under safe conditions.


Assuntos
Carcinoma Hepatocelular/radioterapia , Embolização Terapêutica , Neoplasias Hepáticas/radioterapia , Exposição Ocupacional , Exposição à Radiação , Radioisótopos de Ítrio/administração & dosagem , Embolização Terapêutica/instrumentação , Embolização Terapêutica/métodos , Embolização Terapêutica/estatística & dados numéricos , Feminino , Dedos/efeitos da radiação , Mãos/efeitos da radiação , Humanos , Masculino , Microesferas , Pessoa de Meia-Idade , Doses de Radiação , Dosímetros de Radiação , Proteção Radiológica/métodos , Fatores de Tempo
4.
An. Facultad Med. (Univ. Repúb. Urug., En línea) ; 8(1): e203, jun. 2021. tab, graf
Artigo em Espanhol | LILACS, UY-BNMED, BNUY | ID: biblio-1248717

RESUMO

El vino tinto variedad Vitis vinifera L. cv Tannat en los últimos años ha tomado relevancia por su alta concentración de polifenoles, esto le podría significar un rol protector sobre el genoma disminuyendo la formación de lesiones oxidativas. Los efectos a nivel celular de las radiaciones ionizantes en blancos como el ADN, componentes de cascadas de transducción de señales, resultan en lesiones letales, mutagénicas y recombinogénicas y en retardos en el ciclo celular. Se utilizó como modelo eucariota poblaciones de Saccharomyces cerevisiae en fase exponencial expuestas a radiación gamma (200 Gy) en presencia, o ausencia, de vino Tannat (10 % v/v) o de ácido tánico (60 µg/mL). Se estimaron las probabilidades de sobrevida y frecuencia mutagénica en distintas condiciones. Las muestras celulares expuestas a radiación ionizante presentaron una fracción de sobrevida de 0.21 ± 0.02 mientras que en las muestras irradiadas en presencia de vino Tannat o de ácido tánico la fracción de sobrevida fue de 0.33 ± 0.03 y 0.30 ± 0.03 respectivamente. Se observó en las poblaciones irradiadas un aumento significativo de la probabilidad de mutagénesis. En el caso de los tratamientos combinados se observó que la frecuencia mutagénica fue significativamente menor (gamma Tannat: 33%, gamma ácido tánico: 45% ). Estos resultados preliminares podrían indicar radioprotección moderada por parte de los compuestos estudiados, efecto que podría explicarse por las interacciones redox del ácido tánico y polifenoles contenidos en el vino con los radicales libres formados por las radiaciones ionizantes, además de la activación de vías de reparación genómica.


The red wine variety Vitis vinifera L. cv Tannat in recent years has gained relevance due to its high concentration of polyphenols, this could mean a protective role on the genome, reducing the formation of oxidative lesions. The effects at the cellular level of ionizing radiation on targets such as DNA, components of signal transduction cascades, result in lethal, mutagenic and recombinogenic lesions and delays in the cell cycle. Exponential phase populations of Saccharomyces cerevisiae exposed to gamma radiation (200 Gy) in the presence or absence of Tannat wine (10% v / v) or tannic acid (60 µg / ml) were used as a eukaryotic model. The probabilities of survival and mutagenic frequency in different conditions were estimated. Cellular samples exposed to ionizing radiation presented a survival fraction of 0.21 ± 0.02, while in samples irradiated in the presence of Tannat wine or tannic acid, the survival fraction was 0.33 ± 0.03 and 0.30 ± 0.03 respectively. A significant increase in the probability of mutagenesis was observed in irradiated populations. In the case of the combined treatments, it was observed that the mutagenic frequency was significantly lower (Tannat gamma: 33%, Tannic acid gamma: 45%). These preliminary results could indicate moderate radioprotection by the compounds studied, an effect that could be explained by the redox interactions of tannic acid and polyphenols contained in wine with the free radicals formed by ionizing radiation, in addition to the activation of genomic repair pathways.


A variedade de vinho tinto Vitis vinifera L. cv Tannat nos últimos anos tem ganhado relevância devido à sua alta concentração de polifenóis, o que pode significar um papel protetor do genoma, reduzindo a formação de lesões oxidativas. Os efeitos no nível celular da radiação ionizante em alvos como o DNA, componentes de cascatas de transdução de sinal, resultam em lesões letais, mutagênicas e recombinogênicas e atrasos no ciclo celular. Populações de fase exponencial de Saccharomyces cerevisiae expostas à radiação gama (200 Gy) na presença ou ausência de vinho Tannat (10% v / v) ou ácido tânico (60 µg / ml) foram utilizadas como modelo eucariótico. Foram estimadas as probabilidades de sobrevivência e frequência mutagênica em diferentes condições. As amostras celulares expostas à radiação ionizante apresentaram uma fração de sobrevivência de 0,21 ± 0,02, enquanto nas amostras irradiadas na presença de vinho Tannat ou ácido tânico, a fração de sobrevivência foi de 0,33 ± 0,03 e 0,30 ± 0,03, respectivamente. Um aumento significativo na probabilidade de mutagênese foi observado nas populações irradiadas. No caso dos tratamentos combinados, observou-se que a frequência mutagênica foi significativamente menor (Tannat gama: 33%, ácido tânico gama: 45%). Esses resultados preliminares podem indicar radioproteção moderada pelos compostos estudados, efeito que pode ser explicado pelas interações redox do ácido tânico e polifenóis contidos no vinho com os radicais livres formados pela radiação ionizante, além da ativação de vias de reparo genômico.


Assuntos
Animais , Saccharomyces cerevisiae/efeitos dos fármacos , Saccharomyces cerevisiae/genética , Taninos/farmacologia , Mutagênese/efeitos dos fármacos , Polifenóis/farmacologia , Raios gama/efeitos adversos , Protetores contra Radiação/farmacologia , Taxa de Sobrevida , Quimioterapia Combinada , Taxa de Mutação
5.
CES odontol ; 34(1): 52-67, ene.-jun. 2021. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1360261

RESUMO

Resumen El uso de rayos X juega un papel esencial en el diagnóstico y planificación de tratamientos dentales. Los avances tecnológicos de los equipos de rayos X han contribuido al mayor uso de este tipo de radiación en la práctica odontológica. Aunque la exposición a la radiación es baja en estos procedimientos, todavía existe un riesgo que debe reducirse al mínimo necesario a fin de obtener una imagen adecuada para el diagnóstico y a la vez evitar efectos nocivos para el paciente y el personal involucrado. Debido al alto y creciente número de radiografías dentales, el hecho de que niños y adolescentes sean el foco de la mayoría de estas, la subestimación de la cantidad de exámenes radiológicos reportados y la supuesta baja conciencia de estudiantes y profesionales de la odontología sobre los peligros del uso indiscriminado de los rayos X, es necesario adoptar medidas de protección radiológica para mitigar los efectos biológicos radioinducidos. Este artículo tiene como objetivo revisar los principios básicos de la radioprotección que deben considerarse en la práctica dental, con el fin de garantizar el menor daño posible a trabajadores ocupacionalmente expuestos, pacientes y miembros del público.


Resumo O uso dos raios X desempenha um papel essencial no diagnóstico e planejamento de tratamentos dentários. O avanço tecnológico nos equipamentos de raios-X tem contribuído para o aumento do uso deste tipo de radiação na prática odontológica. Embora a exposição à radiação seja baixa nestes procedimentos, ela representa um risco e deve ser reduzida ao mínimo valor necessário para se obter a imagem adequada para o diagnóstico, evitando efeitos nocivos ao paciente e ao pessoal envolvido. Devido ao elevado e crescente número de radiografias odontológicas, ao fato de crianças e adolescentes serem o foco de grande parte delas, a subestimação do número de exames radiológicos notificados e a suposta baixa conscientização de estudantes e profissionais da odontologia sobre os perigos dos uso indiscriminado de raios-x, é precisa a adoção de medidas de radioproteção para mitigar o risco de efeitos nocivos radioinduzidos. Este artigo tem como objetivo revisar os princípios básicos da radioproteção a serem considerados na prática odontológica, a fim de garantir o menor prejuízo possível para trabalhadores ocupacionalmente expostos, pacientes e membros do público.


Abstract The use of X-rays plays an essential role in the diagnosis and planning of dental treatments. Technological advances in X-ray equipment have contributed to the increased use of this type of radiation in dental practice. Although radiation exposure is low in these procedures, there is still a risk. The reduction of the risk to the minimum value possible is necessary to obtain an adequate image for the diagnosis and avoiding harmful effects on the patient and the personnel involved. Due to the high and growing number of dental X-rays, the fact that children and adolescents are the focus of most of them, the underestimation of the number of radiological examinations reported and the supposed low awareness of dental students and professionals about the dangers the indiscriminate use of X-rays, it is necessary to adopt radioprotection measures to mitigate the risk of harmful radioinduced effects. This article aims to review the basic principles of radioprotection to be considered in dental radiology, in order to ensure the least possible damage to occupationally exposed workers, patients and public members.

6.
Bol. latinoam. Caribe plantas med. aromát ; 20(2): 101-122, 2021. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1342191

RESUMO

Humans when exposed to harmful ionising radiations suffer from various pathophysiological disorders including cancer. Radiotherapy is a treatment where these cancerous cells within a tumor aretargeted and killed by means of high energy waves. This therapy is very expensive and involves highly sophisticated instruments. In addition to this, most synthetic radioprotectors including Amifostine have been found to possess toxicity. This led researchers to develop a novel, economically viable, and efficient therapeutic alternative to radiation therapy. The last two decades have observed a major shift towards investigating natural products as radioprotectors, as these are immensely effective in terms of their potential bioequivalence relative to many of the established synthetic compounds available. Taking into account the limitations of radiation therapy, an approach 'Integrative Oncology' that involves a combination of both traditional and conventional medical treatment are used nowadays to treat patients suffering from cancer and associated mental and psychological disorders.


Los seres humanos, cuando se exponen a radiaciones ionizantes nocivas, sufren diversos trastornos fisiopatológicos, incluido el cáncer. La radioterapia es un tratamiento en el que estas células cancerosas dentro de un tumor son atacadas y destruidas por medio de ondas de alta energía. Esta terapia es muy cara e implica instrumentos muy sofisticados. Además de esto, se ha descubierto que la mayoría de los radioprotectores sintéticos, incluida la amifostina, poseen toxicidad. Esto llevó a los investigadores a desarrollar una novedosa, económicamente viable y eficiente alternativa terapéutica a la radioterapia. En las dos últimas décadas se ha observado un cambio importante hacia la investigación de productos naturales como radioprotectores, ya que son inmensamente eficaces en términos de su potencial bioequivalencia en relación con muchos de los compuestos sintéticos establecidos disponibles. Teniendo en cuenta las limitaciones de la radioterapia, hoy en día se utiliza un enfoque de "Oncología Integrativa" que implica una combinación de tratamiento médico tradicional y convencional para tratar a pacientes que padecen cáncer y trastornos mentales y psicológicos asociados.


Assuntos
Humanos , Plantas/química , Protetores contra Radiação , Produtos Biológicos , Oncologia Integrativa/métodos , Radioterapia/métodos , Dano ao DNA , Radioterapia (Especialidade)/métodos , Instabilidade Genômica
7.
Rev. chil. cardiol ; 39(2): 105-113, ago. 2020. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1138523

RESUMO

ANTECEDENTES: Las unidades de Cardiología intervencional han evidenciado un número creciente de procedimientos, cada vez más variados y complejos, lo cual podría eventualmente generar daños a los profesionales ocupacionalmente expuestos a radiaciones ionizantes (POEs) de no contar con los adecuados elementos de radioprotección y un uso correcto de ellos. OBJETIVO: Caracterizar la disponibilidad y utilización de los elementos de radioprotección y dosimetría de unidades de cardiología intervencionista de centros Sudamericanos. MATERIAL Y MÉTODOS: Se realizó una encuesta autoaplicada a 139 POEs, de ambos sexos de 7 países, a través de una plataforma on-line, se les consultó sobre características demográficas, dosimétricas y de radioprotección. RESULTADOS: Los elementos de radioprotección más tradicionales; delantales y cuellos plomados se utilizaron un 99,5 % y 98,4 % respectivamente, aquellos elementos más recientes como gafas, gorros y paños plomados solo alcanzaron un 36,8 %, 6,8 % y 34,2%, de utilización respectivamente, en cuanto a la utilización de los dosímetros, solo un 7,9 % lo hace apegado a las normas de la Organización Internacional de Energía Atómica (OIEA). CONCLUSIÓN: Se constató en la muestra analizada una falta de elementos de radioprotección y un uso inadecuado de ellos, urge realizar intervenciones educativas y técnicas para mejorar estos datos.


BACKGROUND: Due to the increasing number of interventional cardiology procedures currently performed, health professionals (POE) are exposed to ionizing radiation unless adequate protective elements are used. AIM: to describe the use of radioprotection elements and dosimetry in interventional cardiology laboratories in South America. METHODS: A self-administered survey was performed on 139 POE of both sexes and 7 countries using an online platform. Demographic data, dosimetry and characteristics of radioprotection analyzed. RESULTS: Commonly used radioprotective elements (lead aprons and collars) were used in 99.5% and 98% respectively. Recently introduced protection elements like lead goggles, caps and drapery were used in 36.8, 6.8 and 34.2% , respectively. Dosimetry according to the International Atomic Energy Commission (OIAE) was performed in only 7.9% of the procedures. CONCLUSION: there is a severe lack of adequate radioprotection during interventional cardiology procedures. Urgent measures, including technical implementation and educational interventions are needed to improve radioprotection in interventional cardiology.


Assuntos
Humanos , Masculino , Feminino , Adulto , Proteção Radiológica/métodos , Radiografia Intervencionista/efeitos adversos , Exposição Ocupacional/prevenção & controle , Serviço Hospitalar de Cardiologia , Doses de Radiação , Radiação Ionizante , Proteção Radiológica/instrumentação , Proteção Radiológica/estatística & dados numéricos , América do Sul , Projetos Piloto , Inquéritos e Questionários , Autorrelato , Equipamento de Proteção Individual
8.
Rev. colomb. cardiol ; 27(S1): 72-78, Mar. 2020. graf, ilus
Artigo em Espanhol | LILACS, UY-BNMED, BNUY | ID: biblio-1392339

RESUMO

El número y la complejidad de los procedimientos de diagnóstico e intervencionismo cardiovascular han incrementado de manera significativa, hecho que genera mayor exposición a dosis bajas de radiación ionizante debido a la radiación dispersa por el paciente. El cristalino es una de las estructuras más sensibles a la radiación y las cataratas son la enfermedad ocular más estudiada y frecuente en el personal de la salud ocupacionalmente expuesto a dosis bajas de radiación. La formación de cataratas es un proceso multifactorial y la exposición a la radiación ionizante se ha asociado a opacidades subcapsulares posteriores, que es la forma más común de lesión, seguida por las cataratas corticales. Existen varios estudios que han evaluado los efectos de la exposición ocupacional por radiación ionizante en el cristalino en cardiólogos intervencionistas, comparándolos con controles no expuestos. Concluyen que hay mayor prevalencia de opacidades subcapsulares posteriores en el personal expuesto a radiación ionizante, especialmente en los cardiólogos intervencionistas (por trabajar muy cerca del generador de rayos X), las cuales están relacionadas con la duración de la práctica del intervencionismo cardíaco y disminuyen con el uso regular de los lentes plomados. Lo llamativo de muchos estudios es el bajo uso por parte de los cardiólogos intervencionistas de los elementos de protección radiológica, especialmente gafas y mampara plomada, las cuales han demostrado efectividad en la reducción de la radiación ionizante recibida por el personal de la sala de cateterismo cardiaco.


As the number and complexity of diagnostic and cardiovascular intervention procedures has increased significantly, this has led to a greater exposure to low doses of ionising radiation due to the radiation dispersal by the patient. The crystalline lens is one of the structures most sensitive to radiation, and cataracts are the most studied eye disease, and are common in health staff occupationally exposed to low radiation doses. The formation of cataracts is a process involving many factors, and exposure to ionising radiation has been associated with posterior sub-capsular opacities, the most common form of the injury, followed by cortical cataracts. There are several studies that have evaluated the effects of occupational exposure due to ionising radiation in the crystalline lens in interventionist cardiologists, and comparing them with non-exposed controls. They conclude that there is a higher prevalence of posterior sub-capsular opacities in personnel exposed to ionising radiation, especially in interventionist cardiologists (due to working very near the X-ray generator). These are associated with the duration of the practice of cardiac interventions, and decrease with the regular use of leaded glasses. The low use of radiation protection wear by interventionist cardiologists is highlighted in many studies, especially glasses and a leaded screen, which have shown to be effective in the reduction in the ionising radiation by the staff in the cardiac catheterisation room.


Assuntos
Humanos , Radiação Ionizante , Proteção Radiológica , Catarata/etiologia , Traumatismos Oculares/etiologia , Cristalino/efeitos da radiação , Relação Dose-Resposta à Radiação , Doenças Profissionais
9.
Acta bioquím. clín. latinoam ; 53(3): 397-408, set. 2019. ilus, graf, tab
Artigo em Espanhol | LILACS | ID: biblio-1038108

RESUMO

Entre los escasos radioprotectores en uso, la amifostina resulta eficaz para reducir la toxicidad aguda inducida por la radiación ionizante. Sin embargo, presenta efectos tóxicos importantes que impiden su uso repetido o en dosis altas. Es necesario entonces desarrollar radioprotectores menos tóxicos, por sí mismos o como coadyuvantes de la amifostina en dosis bajas. Se expusieron ratas Sprague-Dawley a una dosis de rayos X de 6 Gy (cuerpo entero). Se ensayó el butirato de sodio como mitigante luego de una dosis baja de amifostina previa a la irradiación. A distintos tiempos después de la irradiación se realizó el recuento de eritrocitos, leucocitos y la fórmula leucocitaria. Los efectos genotóxicos se evaluaron en leucocitos de sangre mediante el ensayo Cometa. Se realizaron también estudios de supervivencia a 60 días y la evaluación histológica del duodeno e intestino grueso. El efecto del tratamiento resultó moderadamente protector respecto de la recuperación de los valores normales de eritrocitos, leucocitos y la fórmula leucocitaria en los animales sobrevivientes en ambos sexos, así como de los epitelios intestinales y el ADN de los leucocitos. También aumentó significativamente la sobrevida a 60 días. La radioprotección con amifostina en una dosis baja seguida de una mitigación con butirato fue claramente significativa.


Among the few radioprotectors in use, amifostine is effective in reducing the acute toxicity induced by ionizing radiation. However, it has important toxic effects that prevent its repeated use or in high doses. It is necessary then to develop less toxic radioprotectors, by themselves or as adjuvants of amifostine in low doses. Sprague-Dawley rats were exposed to an X-ray dose of 6 Gy (whole body). Sodium butyrate was tested as a mitigant after a low dose of amifostine prior to irradiation. At different times after the irradiation, the erythrocytes, leukocytes and the leukocyte formula were counted. Genotoxic effects were evaluated in blood leukocytes by the Comet assay. Sixty-day survival studies and histological evaluation of the duodenum and large intestine were also performed. The effect of the treatment was moderately protective with respect to the recovery of the normal values of erythrocytes, leukocytes and the leukocyte formula in the surviving animals in both sexes as well as for the intestinal epithelia and leukocytes DNA. It also significantly increased the 60-day survival. The radioprotection with amifostine in a low dose followed by mitigation with butyrate was clearly significant.


Entre os poucos radioprotetores em uso, a amifostina é eficaz na redução da toxicidade aguda induzida pela radiação ionizante. No entanto, tem importantes efeitos tóxicos que impedem seu uso repetido ou em altas doses. É necessário, então, desenvolver radioprotetores menos tóxicos, isoladamente ou como coadjuvantes da amifostina em baixas doses. Ratos Sprague-Dawley foram expostos a uma dose de raios X de 6 Gy (corpo inteiro). O butirato de sódio foi testado como mitigante após uma dose baixa de amifostina antes da irradiação. Em diferentes momentos após a irradiação, os eritrócitos, leucócitos e a fórmula de leucócitos foram contados. Os efeitos genotóxicos foram avaliados em leucócitos de sangue pelo ensaio Cometa. Estudos de sobrevida de 60 dias e avaliação histológica do duodeno e do intestino grosso também foram realizados. O efeito do tratamento resultou moderadamente protetor em relação à recuperação de valores normais de eritrócitos, leucócitos e fórmula leucocitária nos animais sobreviventes em ambos os sexos, bem como protegeu epitélios intestinais e o DNA dos leucócitos. Também aumentou significativamente a sobrevida para 60 dias. A radioproteção com amifostina em baixa dose seguida de uma mitigação com butirato foi claramente significativa.


Assuntos
Animais , Ratos , Sódio/toxicidade , Butiratos/toxicidade , Amifostina/toxicidade , Radiação Ionizante , Proteção Radiológica , Butiratos/administração & dosagem , Ratos Sprague-Dawley , Amifostina/administração & dosagem
10.
Neurocirugia (Astur : Engl Ed) ; 29(4): 187-200, 2018.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-29636275

RESUMO

OBJECTIVE: To describe pros and cons of some radiation protection measures and the implications on the design of a neurosurgery operating room. MATERIAL AND METHODS: Concurring with the acquisition and use of an O-arm device, a structural remodeling of our neurosurgery operating room was carried out. The theater was enlarged, the shielding was reinforced and a foldable leaded screen was installed inside the operating room. Radiation doses were measured in front of and behind the screen. RESULTS: The screen provides whole-body radiation protection for all the personnel inside the theater (effective dose <5µSv at 2,5 m from the gantry per O-arm exploration; 0,0µSv received behind the screen per O-arm exploration; and undetectable cumulative annual radiation dose behind the screen), obviates the need for leaded aprons and personal dosimeters, and minimizes the circulation of personnel. Enlarging the size of the operating room allows storing the equipment inside and minimizes the risk of collision and contamination. Rectangular rooms provide greater distance from the source of radiation. CONCLUSION: Floor, ceiling and walls shielding, a rectangular-shaped and large enough theater, the presence of a foldable leaded screen, and the security systems precluding an unexpected irruption into the operating room during irradiation are relevant issues to consider when designing a neurosurgery operating theater.


Assuntos
Arquitetura Hospitalar , Procedimentos Neurocirúrgicos , Traumatismos Ocupacionais/prevenção & controle , Salas Cirúrgicas , Lesões por Radiação/prevenção & controle , Proteção Radiológica , Humanos
11.
Rev. argent. salud publica ; 9(36): 35-38, 2018.
Artigo em Espanhol | LILACS | ID: biblio-968275

RESUMO

Introducción: La cultura de seguridad del paciente implica un compromiso de pacientes y familiares, personal de salud, directivos y responsables de desarrollar e implementar las políticas sanitarias. Su fortalecimiento aumenta la seguridad de todos los involucrados en las prácticas con radiaciones ionizantes, minimizando los riesgos que atentan contra la salud individual, colectiva y ambiental. Objetivos: Introducir el concepto de cultura de seguridad del paciente aplicado a prácticas que utilizan radiaciones ionizantes en el ámbito de la salud pública. Método: Revisión bibliográfica para investigar las experiencias relacionadas con la cultura de seguridad en las prácticas médicas que utilizan fuentes de radiación ionizante, en sentido general. Resultados: Se precisaron los conceptos de cultura, cultura de seguridad y cultura de seguridad del paciente, enfatizando la necesidad de crear un ambiente propicio para reducir la probabilidad de incidentes y accidentes. Conclusiones: El compromiso con la seguridad del paciente y la cultura de seguridad del paciente debe estar lo suficientemente consolidado como para aceptar la responsabilidad y el desafío de garantizar que los pacientes estén y se sientan seguros. Las instituciones que realizan actividades con fuentes de radiación tienen la responsabilidad de alcanzar y sostener el más alto nivel de cultura de seguridad.


Assuntos
Humanos , Pacientes , Proteção Radiológica , Saúde Pública
12.
Acta bioquím. clín. latinoam ; 50(4): 733-744, dic. 2016. ilus, graf, tab
Artigo em Espanhol | LILACS | ID: biblio-837647

RESUMO

Entre los radioprotectores con uso clínico se destaca la amifostina (WR- 2721), eficaz pero con efectos secundarios que impiden su uso repetitivo. Es interés de los autores desarrollar radioprotectores menos tóxicos, por sí mismos o como coadyuvantes de amifostina. Ratas machos o hembras se expusieron a una dosis de rayos X de 2 Gy. Se ensayó el piruvato de etilo, solo o conjuntamente con amifostina. Cuarenta y ocho horas después de la exposición a la radiación, se realizó el recuento de eritrocitos, de leucocitos y la fórmula leucocitaria. Los efectos genotóxicos se evaluaron en leucocitos de sangre mediante el ensayo Cometa. Se realizaron también estudios de supervivencia a 60 días post-irradiación. En los animales irradiados disminuyeron los eritrocitos, y el recuento de leucocitos se redujo drásticamente respecto al control, presentando además una fórmula alterada. El tratamiento con piruvato de etilo resultó en una protección de los eritrocitos en ambos sexos. El daño genético disminuyó significativamente por el tratamiento con piruvato de etilo solo o combinado con amifostina, y en hembras se observó una mayor supervivencia solo con el tratamiento combinado. El piruvato de etilo mostró una acción radioprotectora significativa, que podría mejorarse aumentando la dosis o el tiempo de tratamiento, ya que tiene muy baja toxicidad.


Among the currently available radioprotectors, only amifostine (WR-2721) has shown in clinical trials to reduce radiation-induced toxicity. This compound is an efficient radioprotector but it exhibits some undesirable side effects which prevent its repetitive use. Efforts are directed to develop radioprotective agents with lower toxicity, with their own protective potential or suitable as coadyuvants of amifostine. The present study describes the results obtained by repetitive oral administration of ethyl pyruvate. Male or female rats were exposed to an X-ray dose of 2 Gy. Forty-eight hours after exposure to radiation, erythrocyte count, leukocyte and differential count were performed. Genotoxic effects were assessed in blood leukocytes by the Comet assay. Survival studies were also performed at 60 days post-irradiation. Eritrocyte and leukocyte were reduced in animals exposed to radiation compared to the control, also presenting an altered formula. Treatment with ethyl pyruvate resulted in a protection on erythrocytes of both sexes. Genetic damage was significantly decreased by ethyl pyruvate alone or combined with amifostine, and in females, higher survival was observed only with combined administration. Ethyl pyruvate showed a significant radioprotective action, which could be improved by increasing the dose or time of treatment because it has low toxicity.


Entre os radioprotetores com uso clínico destaca-se a amifostina (WR-2721) eficaz mas com efeitos secundários que impedem seu uso repetitivo. O interesse dos autores é desenvolver radioprotetores menos tóxicos, por si mesmos ou como coadjuvantes de amistofina. Ratos machos ou fêmeas foram expostos a doses de raios X de 2Gy. Ensaiou-se o piruvato de etila, só ou junto com amifostina. Quarenta e oito horas após a exposição à radiação foi realizada a contagem de eritrócitos, de leucócitos e da fórmula leucocitária. Efeitos genotóxicos foram avaliados em leucócitos do sangue pelo Ensaio Cometa. Estudos de sobrevivência foram também realizados a 60 dias pós-irradiação. Nos animais irradiados diminuíram os eritrócitos, e a contagem de leucócitos se reduziu drasticamente em comparação com o controle, apresentando também uma fórmula alterada. O tratamento com piruvato de etila resultou numa proteção dos eritrócitos em ambos os sexos. O dano genético diminuiu significativamente pelo tratamento com piruvato de etila sozinho ou combinado com amifostina, e nas fêmeas se observou maior sobrevivência só com o tratamento combinado. O piruvato de etila mostrou uma ação radioprotetora significativa, que poderia ser melhorada pelo aumento da dose ou do tempo de tratamento, visto que tem baixa toxicidade.


Assuntos
Ratos , Amifostina/toxicidade , Radiação , Protetores contra Radiação/uso terapêutico , Amifostina/administração & dosagem , Terapêutica/estatística & dados numéricos
13.
Radiologia ; 58 Suppl 2: 92-103, 2016 May.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-27085511

RESUMO

It is essential to minimize exposure to ionizing radiation in children for various reasons. The risk of developing a tumor from exposure to a given dose of radiation is greater in childhood. Various strategies can be used to reduce exposure to ionizing radiation. It is fundamental to avoid unnecessary tests and tests that are not indicated, to choose an alternative test that does not use ionizing radiation, and/or to take a series of measures that minimize the dose of radiation that the patient receives, such as avoiding having to repeat tests, using the appropriate projections, using shields, adjusting the protocol (mAs, Kv, or pitch) to the patient's body volume, etc… When contrast agents are necessary, intracavitary ultrasound agents can be used, although the use of ultrasound agents is also being extended to include intravenous administration. In fluoroscopy, contrast agents with low osmolarity must be used, as in CT where we must adjust the dose and speed of injection to the patient's weight and to the caliber of the peripheral line, respectively. In MRI, only three types of contrast agents have been approved for pediatric use. It is sometimes necessary to use double doses or organ-specific contrast agents in certain clinical situations; the safety of contrast agents for these indications has not been proven, so they must be used off label.


Assuntos
Meios de Contraste , Diagnóstico por Imagem/métodos , Lesões por Radiação/prevenção & controle , Proteção Radiológica , Criança , Humanos , Guias de Prática Clínica como Assunto , Doses de Radiação , Tomografia Computadorizada por Raios X
14.
Lima; s.n; 2015. 49 p. tab, graf.
Tese em Espanhol | LIPECS | ID: biblio-1114183

RESUMO

Objetivo: Evaluar la efectividad de los medios de Radioprotección en el personal de Imagenología del Hospital Nacional de Policía ocupacionalmente expuesto a radiaciones ionizantes en el periodo de Enero a junio del 2011. Material y Método: Método observacional. Tipo de estudio realizado: Prospectivo, Diseño de investigación Transversal, Diseño Cuantitativo desarrollado en el Hospital Nacional de la Policía ubicada en el distrito de Jesús María, departamento de Lima durante el periodo de enero a Junio del 2011. Utilizando un cuestionario de autoevaluación a 46 trabajadores ocupacional mente expuestos a radiaciones de las unidades de radiodiagnóstico y medicina nuclear en el periodo enero 2011- junio 2011. Resultados: Al procesar los cuestionarios con el software SPSS encontramos conocimientos que se presentan agrupados de acuerdo a las actividades profesionales que realizan. La responsabilidad del auxiliar de radiología es diferente al del Tecnólogo médico o al del Médico. Claramente se aprecia que los auxiliares de radiología, cumplen al 100 por ciento con los conocimientos que dan soporte a sus actividades profesionales de esta unidad de competencia. Conclusiones: La autoevaluación demostró que los trabajadores poseen un excelente conocimiento y aplicación de las normas de radioprotección, observándose en ellos la posesión de actitudes idóneas para el trabajo en el servicio de Imagenología del Hospital. De esta manera el trabajador mantiene una actitud preventiva de vigilancia periódica del estado de su salud ante los riesgos laborales.


Purposes: To evaluate the effectiveness of the means of radiation protection the staff at Imaging National Police Hospital occupationally exposed to ionizing radiations in the period from January to June 2011. Materials and methods: Observational method. Type of study accomplished: Prospective, Research Design: Transversal. Quantitative design developed at the National Police Hospital located in the district of Jesus Maria. Lima department during the period from January to June 2011. Using a self-assessment questionnaire to 46 workers occupationally exposed to radiation units radiology and nuclear medicine in the period January 2011-June 2011. Results: When processing the questionnaires using SPSS software are presented know grouped according to the professional activities they perform. The responsibility of the radiology Auxiliary is different from the Medical Technologist or Medical. Clearly it shows that radiology auxiliaries comply 100 percent with the knowledge that give support to your professional activities of this unit of competence. Conclusion: The self-assessment showed that workers have an excellent knowledge and application of radiation protection standards. Showing them the possession of appropriate attitudes for work in the service of the Hospital Imaging. Thus the worker has a preventive attitude of regular monitoring of his health status to the occupational hazards.


Assuntos
Masculino , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Exposição à Radiação , Proteção Radiológica , Radiação Ionizante , Riscos Ocupacionais , Serviço Hospitalar de Medicina Nuclear , Estudos Prospectivos , Estudos Transversais , Estudos de Avaliação como Assunto
15.
Rev Esp Cir Ortop Traumatol ; 58(5): 309-13, 2014.
Artigo em Espanhol | MEDLINE | ID: mdl-25022213

RESUMO

OBJECTIVE: To analyse the exposure of two Orthopaedic Surgeons to ionizing radiations in their daily work, and to review the main national and international recommendations on this subject. MATERIAL AND METHODS: A retrospective study was conducted on the surgical treatments that use fluoroscopy performed by two Orthopaedic Surgeons during a one year period. An evaluation was made of the radiation received, based on measurements of the processes published in the bibliography section. A literature review of international recommendations and regulations is also presented. RESULTS: The radiation received by the two Orthopaedic Surgeons during one year did not exceed the limits of present-day legislation or the new European and international recommendations. The exposure was asymmetrical, with the hands being the most radiated part. The new recommendations reduce the permitted level of radiation on eyes. DISCUSSION: The evaluation of the radiation received demonstrates the need for radiation protection, paying particular attention to the hands and eyes. Good knowledge of operating a fluoroscope and radiation safety measures are also essential.


Assuntos
Fluoroscopia , Exposição Ocupacional , Procedimentos Ortopédicos , Ortopedia , Exposição à Radiação , Humanos , Exposição Ocupacional/efeitos adversos , Salas Cirúrgicas , Exposição à Radiação/efeitos adversos , Proteção Radiológica , Estudos Retrospectivos
16.
Anon.
Rev. argent. radiol ; 78(2): 114-117, jun. 2014. tab
Artigo em Espanhol | BINACIS | ID: bin-131253

RESUMO

El constante crecimiento del uso de radiaciones ionizantes en el Diagnóstico por Imágenes nos obliga a mantener una adecuada gestión de las dosis impartidas a los pacientes en cada estudio realizado. La dosimetría en radiología es un tema difícil de abordar, pero de vital importancia para una adecuada estimación de las dosis con las cuales estamos trabajando. La enorme concientización que, día a día, se percibe en nuestro país en estos temas es la respuesta adecuada a esta problemática. El presente artículo describe las principales unidades dosimétricas utilizadas y ejemplifica de manera sencilla, mediante valores de referencia conocidos internacionalmente, las dosis en radiología.(AU)


Abstract The steady growth in the use of ionizing radiation in diagnostic imaging requires to maintain a proper management of patient’s dose. Dosimetry in Radiology is a difficult topic to address, but vital for proper estimation of the dose the patient is receiving. The awareness that every day is perceived in our country on these issues is the appropriate response to this problem. This article describes the main dosimetric units used and easily exemplifies doses in radiology through internationally known reference values.(AU)

17.
Anon.
Rev. argent. radiol ; 78(2): 114-117, jun. 2014. tab
Artigo em Espanhol | LILACS | ID: lil-734598

RESUMO

El constante crecimiento del uso de radiaciones ionizantes en el Diagnóstico por Imágenes nos obliga a mantener una adecuada gestión de las dosis impartidas a los pacientes en cada estudio realizado. La dosimetría en radiología es un tema difícil de abordar, pero de vital importancia para una adecuada estimación de las dosis con las cuales estamos trabajando. La enorme concientización que, día a día, se percibe en nuestro país en estos temas es la respuesta adecuada a esta problemática. El presente artículo describe las principales unidades dosimétricas utilizadas y ejemplifica de manera sencilla, mediante valores de referencia conocidos internacionalmente, las dosis en radiología.


Abstract The steady growth in the use of ionizing radiation in diagnostic imaging requires to maintain a proper management of patient’s dose. Dosimetry in Radiology is a difficult topic to address, but vital for proper estimation of the dose the patient is receiving. The awareness that every day is perceived in our country on these issues is the appropriate response to this problem. This article describes the main dosimetric units used and easily exemplifies doses in radiology through internationally known reference values.

18.
Rev Esp Med Nucl Imagen Mol ; 32(5): 294-300, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23499122

RESUMO

PURPOSE: The aim of this study was to evaluate the morphological changes of rat lacrimal glands at the third month following radioiodine (RAI) treatment and the radioprotective effect of montelukast (ML) sodium against RAI-related lacrimal gland damage. METHODS: Fifty female Wistar Albino rats were divided into three groups. The control group (n=10) consisted of rats with no intervention. RAI group (n=20) consisted of rats treated with oral (131)I (111 MBq). The ML group (n=20) consisted of rats treated with intraperitoneal 10mg/kg/day ML sodium, starting three days before and continuing for one week after oral RAI administration. Intraorbital (IG), extraorbital (EG) and Harderian glands (HG) were removed bilaterally after three months. RESULTS: The existence of acinar atrophy, acinar fibrosis, abnormal cell lines, peripheral basophilia, cell size variation and decrease in amount of cytoplasm was significantly more common in the RAI-rat treated group than in the ML group, in each of the glands. The ML-treated group had less-frequent cell shape variation in EG (P=0.001) and HG (P=0.027), cell size variation in IG (P<0.001) and HG (P=0.01), ductal pathology in EG (P<0.001) and HG (P<0.001) and lipofuscin accumulation in EG (P=0.001) and in HG (P=0.01) than the RAI-treated group. CONCLUSIONS: RAI treatment seems to cause morphological damage to rat lacrimal glands, and ML sodium effectively protects against damage to lacrimal glands.


Assuntos
Acetatos/uso terapêutico , Radioisótopos do Iodo/toxicidade , Aparelho Lacrimal/efeitos dos fármacos , Quinolinas/uso terapêutico , Lesões Experimentais por Radiação/prevenção & controle , Protetores contra Radiação/uso terapêutico , Acetatos/administração & dosagem , Animais , Atrofia , Ciclopropanos , Avaliação Pré-Clínica de Medicamentos , Feminino , Fibrose , Injeções Intraperitoneais , Aparelho Lacrimal/efeitos da radiação , Aparelho Lacrimal/ultraestrutura , Infiltração de Neutrófilos , Estresse Oxidativo , Quinolinas/administração & dosagem , Lesões Experimentais por Radiação/etiologia , Protetores contra Radiação/administração & dosagem , Distribuição Aleatória , Ratos , Ratos Wistar , Sulfetos , Glândula Tireoide/patologia , Glândula Tireoide/efeitos da radiação
19.
Rev. argent. radiol ; 74(4): 397-402, dic. 2010. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-634819

RESUMO

Objetivo: A partir de la determinación de las dosis en los protocolos habitualmente utilizados en estudios de tomografía computada en una institución, se modificaron la menor cantidad de parámetros radiológicos posibles para bajar las dosis impartidas, sin perder la calidad de la imagen. Materiales y métodos: Para la determinación de las dosis en un tomógrafo General Electric Hi Speed - 120kV Helicoidal, se realizaron mediciones utilizando una cámara de ionización tipo lápiz, un dosímetro, fantomas craneal y abdominal de PMMAde 16 cm y 32 cm de diámetro respectivamente, y un fantoma de agua. Con estos elementos se midieron las dosis habitualmente utilizadas y el ruido correspondiente en cada uno de los estudios. Se trabajó con el grupo de técnicos ymédicos de la institución con el objetivo de disminuir la dosis de cada uno de los protocolos utilizados, manteniendo imágenes con calidad diagnóstica. Resultados: Si bien las dosis de los protocolos utilizados por la institución antes de realizado este estudio se encontraban dentro de los rangos reconocidos internacionalmente, se establecieron nuevos protocolos y se pudieron reducir las dosis entre un 20% a un 30%, sin perder calidad ni presentar inconvenientes para el diagnóstico al grupo médico que trabaja en la institución. Conclusiones: Es fundamental realizar actividades de optimización de protocolos en tomografía computada con el objetivo de disminuir la dosis que reciben los pacientes, modificando apropiadamente los parámetros de los protocolos sin perder calidad diagnóstica ni afectar la actividad médica. Esta tarea debe llevarse a cabo en forma interdisciplinaria.


Purpose: To determine the dose frequently used in computed tomography and to modify radiological parameters in order to optimize each protocol according to the dose administered. Materials and Methods: To determine the dose, measurements were made using a pencil ionization chamber, a dosemeter, a 16 cm PMMAhead phantom and a 32 cm abdominal phantom, and a water phantom. AGeneral Electric Hi Speed - Helical 120kV CT scanner was used. The doses usually administered and the noise in each of the studies were measured using these instruments. Agroup of technicians and radiologists at the institution have sought to reduce the dose of each protocol, while maintaining high quality diagnostic images. Results: Although the protocols previously carried out at the institution did not include large doses, the new doses currently used in all protocols could be reduced by 30% on average. Diagnostic quality was not neglected and the slight increase in noise level was harmless to the group of radiologists. Conclusion: CT protocol optimization is essential to reduce the dose administered to the patient. Neither diagnostic quality nor medical activity should be altered by changes in the technique, which must be carried out by a multidisciplinary team.

20.
West Indian med. j ; 59(2): 122-124, Mar. 2010.
Artigo em Inglês | LILACS | ID: lil-672585

RESUMO

Most ionizing radiation-induced damage is caused by radical oxygen species (ROS). Some radioprotectors, such as amifostine, exert radioprotective effects by scavenging radical oxygen species. Recent studies show that hydrogen (H2) has antioxidant activities that protect the brain and intestine against ischaemia-reperfusion injury and stroke by selectively reducing hydroxyl and peroxynitrite radicals. However, it is seldom regarded as a radioprotective agent. In like manner, we hypothesize that hydrogen may be an effective, specific and novel radioprotective agent. But H2 is explosive, while hydrogen-rich solution (solution such as physiological saline saturated with molecular hydrogen) is safer.


La mayor parte de los efectos dañinos inducidos por la radiación ionizante, son causados por especies radicales de oxígeno (ROS). Algunos radioprotectores, tales como la amifostina, ejercen efectos radioprotectores mediante el rescate de especies radicales de oxígeno. Estudios recientes muestran que el hidrógeno (H2) posee una actividad antioxidante que protege el cerebro y el intestino contra las lesiones por repercusión isquémica y accidente cerebrovascular, mediante la reducción selectiva de radicales de hidroxilo y peroxinitrito. Sin embargo, raramente se le considera como un agente radioprotector. De manera similar, planteamos la hipótesis de que el hidrógeno puede ser un agente radioprotector efectivo, específico y novedoso. Pero el H2 es explosivo, mientras que la solución rica en hidrógeno (como es el caso del suero fisiológico saturado con hidrógeno molecular) es más segura.


Assuntos
Humanos , Antioxidantes/farmacologia , Hidrogênio/farmacologia , Protetores contra Radiação/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...