Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 441
Filtrar
1.
Nano Lett ; 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38981024

RESUMO

Cryogenic temperatures are crucial for the operation of semiconductor quantum electronic devices, yet the heating effects induced by microwave or laser signals used for quantum state manipulation can lead to significant temperature variations at the nanoscale. Therefore, probing the temperature of individual devices in working conditions and understanding the thermodynamics are paramount for designing and operating large-scale quantum computing systems. In this study, we demonstrate high-sensitivity fast thermometry in a silicon nanotransistor at cryogenic temperatures using RF reflectometry. Through this method, we explore the thermodynamic processes of the nanotransistor during and after a laser pulse and determine the dominant heat dissipation channels in the few-kelvin temperature range. These insights are important to understand thermal budgets in quantum circuits, with our techniques being compatible with microwave and laser radiation, offering a versatile approach for studying other quantum electronic devices in working conditions.

2.
Tree Physiol ; 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38952005

RESUMO

Forest ecosystems face increasing drought exposure due to climate change, necessitating accurate measurements of vegetation water content to assess drought stress and tree mortality risks. While Frequency Domain Reflectometry offers a viable method for monitoring stem water content by measuring dielectric permittivity, challenges arise from uncertainties in sensor calibration linked to wood properties and species variability, impeding its wider usage. We sampled tropical forest trees and palms in eastern Amazônia, to evaluate how sensor output differences are controlled by wood density, temperature and taxonomic identity. Three individuals per species were felled and cut into segments (total n = 262), within a diverse dataset comprising five dicotyledonous tree-and three monocotyledonous palm species on a wide range of wood densities. Water content was estimated gravimetrically for each segment using a temporally explicit wet-up/dry-down approach, and the relationship with the dielectric permittivity was examined. Woody tissue density had no significant impact on the calibration, but species identity and temperature significantly affected sensor readings. The temperature artefact was quantitatively important at large temperature differences which may have led to significant bias of daily and seasonal water content dynamics in previous studies. We established the first tropical tree and palm calibration equation that performed well for estimating water content. Notably, we demonstrated that the sensitivity remained consistent across species, enabling the creation of a simplified one-slope calibration for accurate, species-independent measurements of relative water content. Our one-slope calibration serves as a general, and species-independent standard calibration for assessing relative water content in woody tissue, offering a valuable tool for quantifying drought responses and stress in trees and forest ecosystems.

3.
Sensors (Basel) ; 24(11)2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38894072

RESUMO

The large amount of sampled data in coherent phase-sensitive optical time-domain reflectometry (Φ-OTDR) brings heavy data transmission, processing, and storage burdens. By using the comparator combined with undersampling, we achieve simultaneous reduction of sampling rate and sampling resolution in hardware, thus greatly decreasing the sampled data volume. But this way will inevitably cause the deterioration of detection signal-to-noise ratio (SNR) due to the quantization noise's dramatic increase. To address this problem, denoising the demodulated phase signals using compressed sensing, which exploits the sparsity of spectrally sparse vibration, is proposed, thereby effectively enhancing the detection SNR. In experiments, the comparator with a sampling parameter of 62.5 MS/s and 1 bit successfully captures the 80 MHz beat signal, where the sampled data volume per second is only 7.45 MB. Then, when the piezoelectric transducer's driving voltage is 1 Vpp, 300 mVpp, and 100 mVpp respectively, the SNRs of the reconstructed 200 Hz sinusoidal signals are respectively enhanced by 23.7 dB, 26.1 dB, and 28.7 dB by using compressed sensing. Moreover, multi-frequency vibrations can also be accurately reconstructed with a high SNR. Therefore, the proposed technique can effectively enhance the system's performance while greatly reducing its hardware burden.

4.
Sensors (Basel) ; 24(11)2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38894299

RESUMO

This study investigates the dielectric properties of conductive biocomposites (CBs), which are integral to the development of advanced materials for flexible electronics and medical devices. A novel method employing Microwave Reflectometry (MR) is introduced, utilizing a miniaturized Vector Network Analyzer (m-VNA) and a dedicated sensing element (SE), to extract the dielectric properties of CBs. The method is grounded in a minimization principle, aligning the measured S11 reflection scattering parameter with its electromagnetic (EM) simulation, facilitating a refined process for determining the dielectric properties. The experimental setup was meticulously engineered, optimized, and validated using reference dielectric samples (RDSs) with known dielectric properties. The method was then applied to three innovative CBs, resulting in an accurate extrapolation of their dielectric properties. The findings highlight the method's versatility, cost-efficiency, and applicability to ultra-thin and flexible biopolymer films, offering significant potential for advancements in flexible electronics and bio-sensing applications.

5.
Entropy (Basel) ; 26(6)2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38920446

RESUMO

Quantum cryptography revolutionizes secure information transfer, providing defense against both quantum and classical computational attacks. The primary challenge in extending the reach of quantum communication comes from the exponential decay of signals over long distances. We meet this challenge by experimentally realizing the Quantum-Protected Control-Based Key Distribution (QCKD) protocol, utilizing physical control over signal losses. By ensuring significant non-orthogonality of the leaked quantum states, this control severely constrains eavesdroppers' capacities. We demonstrate the performance and scale of our protocol by experiments over a 1707 km long fiber line. The scalability of the QCKD opens the route for globally secure quantum-resistant communication.

6.
Adv Colloid Interface Sci ; 331: 103238, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38917595

RESUMO

Diffuse soft matter interfaces take many forms, from end-tethered polymer brushes or adsorbed surfactants to self-assembled layers of lipids. These interfaces play crucial roles across a multitude of fields, including materials science, biophysics, and nanotechnology. Understanding the nanostructure and properties of these interfaces is fundamental for optimising their performance and designing novel functional materials. In recent years, reflectometry techniques, in particular neutron reflectometry, have emerged as powerful tools for elucidating the intricate nanostructure of soft matter interfaces with remarkable precision and depth. This review provides an overview of selected recent developments in reflectometry and their applications for illuminating the nanostructure of diffuse interfaces. We explore various principles and methods of neutron and X-ray reflectometry, as well as ellipsometry, and discuss advances in their experimental setups and data analysis approaches. Improvements to experimental neutron reflectometry methods have enabled greater time resolution in kinetic measurements and elucidation of diffuse structure under shear or confinement, while innovation in analysis protocols has significantly reduced data processing times, facilitated co-refinement of reflectometry data from multiple instruments and provided greater-than-ever confidence in proposed structural models. Furthermore, we highlight some significant research findings enabled by these techniques, revealing the organisation, dynamics, and interfacial phenomena at the nanoscale. We also discuss future directions and potential advancements in reflectometry techniques. By shedding light on the nanostructure of diffuse interfaces, reflectometry techniques enable the rational design and tailoring of interfaces with enhanced properties and functionalities.

7.
Biomolecules ; 14(5)2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38785938

RESUMO

The adsorption kinetics of human serum albumin (HSA) on bare and poly-L-arginine (PARG)-modified silica substrates were investigated using reflectometry and atomic force microscopy (AFM). Measurements were carried out at various pHs, flow rates and albumin concentrations in the 10 and 150 mM NaCl solutions. The mass transfer rate constants and the maximum protein coverages were determined for the bare silica at pH 4.0 and theoretically interpreted in terms of the hybrid random sequential adsorption model. These results were used as reference data for the analysis of adsorption kinetics at larger pHs. It was shown that the adsorption on bare silica rapidly decreased with pH and became negligible at pH 7.4. The albumin adsorption on PARG-functionalized silica showed an opposite trend, i.e., it was negligible at pH 4 and attained maximum values at pH 7.4 and 150 mM NaCl, the conditions corresponding to the blood serum environment. These results were interpreted as the evidence of a significant role of electrostatic interactions in the albumin adsorption on the bare and PARG-modified silica. It was also argued that our results can serve as useful reference data enabling a proper interpretation of protein adsorption on substrates functionalized by polyelectrolytes.


Assuntos
Polieletrólitos , Albumina Sérica , Dióxido de Silício , Dióxido de Silício/química , Adsorção , Humanos , Cinética , Concentração de Íons de Hidrogênio , Albumina Sérica/química , Polieletrólitos/química , Poliaminas/química , Peptídeos/química , Microscopia de Força Atômica , Albumina Sérica Humana/química
8.
Adv Colloid Interface Sci ; 329: 103187, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38788307

RESUMO

The history of the topic of proteins at soft interfaces dates back to the 19th century, and until the present day, it has continuously attracted great scientific interest. A multitude of experimental methods and theoretical approaches have been developed to serve the research progress in this large domain of colloid and interface science, including the area of soft colloids such as foams and emulsions. From classical methods like surface tension adsorption isotherms, surface pressure-area measurements for spread layers, and surface rheology probing the dynamics of adsorption, nowadays, advanced surface-sensitive techniques based on spectroscopy, microscopy, and the reflection of light, X-rays and neutrons at liquid/fluid interfaces offers important complementary sources of information. Apart from the fundamental characteristics of protein adsorption layers, i.e., surface tension and surface excess, the nanoscale structure of such layers and the interfacial protein conformations and morphologies are of pivotal importance for extending the depth of understanding on the topic. In this review article, we provide an extensive overview of the application of three methods, namely, ellipsometry, X-ray reflectometry and neutron reflectometry, for adsorption and structural studies on proteins at water/air and water/oil interfaces. The main attention is placed on the development of experimental approaches and on a discussion of the relevant achievements in terms of notable experimental results. We have attempted to cover the whole history of protein studies with these techniques, and thus, we believe the review should serve as a valuable reference to fuel ideas for a wide spectrum of researchers in different scientific fields where proteins at soft interface may be of relevance.


Assuntos
Proteínas , Proteínas/química , Adsorção , Propriedades de Superfície , Água/química , Coloides/química
9.
J Colloid Interface Sci ; 670: 563-575, 2024 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-38776691

RESUMO

The interactions of viral fusion peptides from influenza (E4K and Ac-E4K) and human immunodeficiency virus (gp41 and Ac-gp41) with planar lipid bilayers and monolayers was investigated herein. A combination of surface-sensitive techniques, including quartz crystal microbalance with dissipation (QCM-D), Langmuir-Blodgett area-pressure isotherms with Micro-Brewster angle microscopy, and neutron reflectometry, was employed. Differences in the interactions of the viral fusion peptides with lipid bilayers featuring ordered and disordered phases, as well as lipid rafts, were revealed. The HIV fusion peptide (gp41) exhibited strong binding to the DOPC/DOPS bilayer, comprising a liquid disordered phase, with neutron reflectometry (NR) showing interaction with the bilayer's headgroup area. Conversely, negligible binding was observed with lipid bilayers in a liquid ordered phase. Notably, the influenza peptide (E4K) demonstrated slower binding kinetics with DOPC/DOPS bilayers and distinct interactions compared to gp41, as observed through QCM-D. This suggests different mechanisms of interaction with the lipid bilayers: one peptide interacts more within the headgroup region, while the other is more involved in transmembrane interactions. These findings hold implications for understanding viral fusion mechanisms and developing antimicrobials and antivirals targeting membrane interactions. The differential binding behaviours of the viral fusion peptides underscore the importance of considering membrane composition and properties in therapeutic strategy design.


Assuntos
Antivirais , Proteína gp41 do Envelope de HIV , Bicamadas Lipídicas , Bicamadas Lipídicas/química , Bicamadas Lipídicas/metabolismo , Proteína gp41 do Envelope de HIV/química , Proteína gp41 do Envelope de HIV/metabolismo , Antivirais/química , Antivirais/farmacologia , Antivirais/metabolismo , Humanos , Orthomyxoviridae/efeitos dos fármacos , Orthomyxoviridae/metabolismo , Técnicas de Microbalança de Cristal de Quartzo
10.
Heliyon ; 10(5): e27246, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38562509

RESUMO

In this study, an optical investigation in a wide spectral range of polymer-like (SiOxCyHz) thin films deposited by plasma-enhanced chemical vapor deposition (PECVD) is presented. The primary focus is on assessing the homogeneity of the grown films. Within the PECVD, it is possible to alter the properties of the deposited material by continually adjusting deposition process parameters and hence allow for the growth of inhomogeneous layers. However, as shown in this study, the growth of homogeneous layers could be similarly challenging. This challenge is especially pronounced at the beginning of the deposition process, where it is necessary to consider the influence of the substrate among other factors, as even slight variations in the deposition conditions can lead to the formation of inhomogeneous layers. Several series of polymer-like thin films were deposited onto silicon substrates with the goal of producing homogeneous layers, i.e. all deposition parameters were held constant. These samples were optically characterized with a special interest in homogeneity, especially at the beginning of the growth. It was found that initial inhomogeneous growth is always present. The thickness of the initial inhomogeneous part was found to be surprisingly large.

11.
J Appl Crystallogr ; 57(Pt 2): 314-323, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38596729

RESUMO

X-ray reflectometry (XRR) is a powerful tool for probing the structural characteristics of nanoscale films and layered structures, which is an important field of nanotechnology and is often used in semiconductor and optics manufacturing. This study introduces a novel approach for conducting quantitative high-resolution millisecond monochromatic XRR measurements. This is an order of magnitude faster than in previously published work. Quick XRR (qXRR) enables real time and in situ monitoring of nanoscale processes such as thin film formation during spin coating. A record qXRR acquisition time of 1.4 ms is demonstrated for a static gold thin film on a silicon sample. As a second example of this novel approach, dynamic in situ measurements are performed during PMMA spin coating onto silicon wafers and fast fitting of XRR curves using machine learning is demonstrated. This investigation primarily focuses on the evolution of film structure and surface morphology, resolving for the first time with qXRR the initial film thinning via mass transport and also shedding light on later thinning via solvent evaporation. This innovative millisecond qXRR technique is of significance for in situ studies of thin film deposition. It addresses the challenge of following intrinsically fast processes, such as thin film growth of high deposition rate or spin coating. Beyond thin film growth processes, millisecond XRR has implications for resolving fast structural changes such as photostriction or diffusion processes.

12.
J Appl Crystallogr ; 57(Pt 2): 456-469, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38596736

RESUMO

Due to the ambiguity related to the lack of phase information, determining the physical parameters of multilayer thin films from measured neutron and X-ray reflectivity curves is, on a fundamental level, an underdetermined inverse problem. This ambiguity poses limitations on standard neural networks, constraining the range and number of considered parameters in previous machine learning solutions. To overcome this challenge, a novel training procedure has been designed which incorporates dynamic prior boundaries for each physical parameter as additional inputs to the neural network. In this manner, the neural network can be trained simultaneously on all well-posed subintervals of a larger parameter space in which the inverse problem is underdetermined. During inference, users can flexibly input their own prior knowledge about the physical system to constrain the neural network prediction to distinct target subintervals in the parameter space. The effectiveness of the method is demonstrated in various scenarios, including multilayer structures with a box model parameterization and a physics-inspired special parameterization of the scattering length density profile for a multilayer structure. In contrast to previous methods, this approach scales favourably when increasing the complexity of the inverse problem, working properly even for a five-layer multilayer model and a periodic multilayer model with up to 17 open parameters.

13.
Sensors (Basel) ; 24(7)2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38610588

RESUMO

In this paper, we propose and demonstrate a network analysis optical frequency domain reflectometer (NA-OFDR) for distributed temperature measurements at high spatial (down to ≈3 cm) and temperature resolution. The system makes use of a frequency-stepped, continuous-wave (cw) laser whose output light is modulated using a vector network analyzer. The latter is also used to demodulate the amplitude of the beat signal formed by coherently mixing the Rayleigh backscattered light with a local oscillator. The system is capable of attaining high measurand resolution (≈50 mK at 3-cm spatial resolution) thanks to the high sensitivity of coherent Rayleigh scattering to temperature. Furthermore, unlike the conventional optical-frequency domain reflectometry (OFDR), the proposed system does not rely on the use of a tunable laser and therefore is less prone to limitations related to the laser coherence or sweep nonlinearity. Two configurations are analyzed, both numerically and experimentally, based on either a double-sideband or single-sideband modulated probe light. The results confirm the validity of the proposed approach.

14.
Sci Technol Adv Mater ; 25(1): 2315015, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38455384

RESUMO

We report investigations of the magnetic textures in periodic multilayers [Pt(1 nm)/(CoFeB(0.8 nm)/Ru(1.4 nm)]10 using polarised neutron reflectometry (PNR) and small-angle neutron scattering (SANS). The multilayers are known to host skyrmions stabilized by Dzyaloshinskii-Moriya interactions induced by broken inversion symmetry and spin-orbit coupling at the asymmetric interfaces. From depth-dependent PNR measurements, we observed well-defined structural features and obtained the layer-resolved magnetization profiles. The in-plane magnetization of the CoFeB layers calculated from fitting of the PNR profiles is found to be in excellent agreement with magnetometry data. Using SANS as a bulk probe of the entire multilayer, we observe long-period magnetic stripe domains and skyrmion ensembles with full orientational disorder at room temperature. No sign of skyrmions is found below 250 K, which we suggest is due to an increase of an effective magnetic anisotropy in the CoFeB layer on cooling that suppresses skyrmion stability. Using polarised SANS at room temperature, we prove the existence of pure Néel-type windings in both stripe domain and skyrmion regimes. No Bloch-type winding admixture, i.e. an indication for hybrid windings, is detected within the measurement sensitivity, in good agreement with expectations according to our micromagnetic modelling of the multilayers. Our findings using neutron techniques provide valuable microscopic insights into the rich magnetic behavior of skyrmion-hosting multilayers, which are essential for the advancement of future skyrmion-based spintronic devices.


The study presents a unique investigation of [Pt/CoFeB/Ru]10 multilayers, revealing suppressed skyrmion phases, intricate magnetic domain structures, and Néel-type domain walls, providing crucial insights for spintronic applications.

15.
Methods Mol Biol ; 2778: 273-290, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38478284

RESUMO

The ß-barrel assembly machinery (BAM) complex in Gram-negative bacteria facilitates the assembly of ß-barrel proteins into the outer membrane. Understanding the protein-protein interactions within this complex is essential for unravelling its functional mechanisms. Here, we present the use of neutron reflectometry for investigating the organization of ß-barrel membrane protein complexes in the membrane environment. The spatial organization, protein positioning, protein-lipid interactions, and conformational changes within the complex can be elucidated by this method.

16.
Adv Colloid Interface Sci ; 325: 103120, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38428362

RESUMO

The last couple of decades have seen an explosion of novel colloidal drug delivery systems, which have been demonstrated to increase drug efficacy, reduce side-effects, and provide various other advantages for both small-molecule and biomacromolecular drugs. The interactions of delivery systems with biomembranes are increasingly recognized to play a key role for efficient eradication of pathogens and cancer cells, as well as for intracellular delivery of protein and nucleic acid drugs. In parallel, there has been a broadening of methodologies for investigating such systems. For example, advanced microscopy, mass-spectroscopic "omic"-techniques, as well as small-angle X-ray and neutron scattering techniques, which only a few years ago were largely restricted to rather specialized areas within basic research, are currently seeing increased interest from researchers within wide application fields. In the present discussion, focus is placed on the use of neutron reflectometry to investigate membrane interactions of colloidal drug delivery systems. Although the technique is still less extensively employed for investigations of drug delivery systems than, e.g., X-ray scattering, such studies may provide key mechanistic information regarding membrane binding, re-modelling, translocation, and permeation, of key importance for efficacy and toxicity of antimicrobial, cancer, and other therapeutics. In the following, examples of this are discussed and gaps/opportunities in the research field identified.


Assuntos
Sistemas de Liberação de Medicamentos , Proteínas , Preparações Farmacêuticas , Nêutrons
17.
Sensors (Basel) ; 24(6)2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38544023

RESUMO

The Jones matrix and the Mueller matrix of the coherent Rayleigh backscattering (RB) in single-mode fibers (SMFs) have been derived recently. It has been shown that both matrices depict two polarization effects-birefringence and polarization-dependent loss (PDL)-although the SMF under investigation is purely birefringent, having no PDL. In this paper, we aim to perform a theoretical analysis of both matrices using polar decomposition. The derived sub-Jones/Mueller matrices, representing birefringence and PDL, respectively, can be used to investigate the polarization properties of the coherent RB. As an application of the theoretical results, we use the derived formulas to investigate the polarization properties of the optical signals in phase-sensitive optical time-domain reflectometry (φ-OTDR). For the first time, to our knowledge, by using the derived birefringence-Jones matrix, the common optical phase of the optical signal in φ-OTDR is obtained as the function of the forward phase and birefringence distributions. By using the derived PDL-Mueller matrix, the optical intensity of the optical signal in φ-OTDR is obtained as the function of the forward phase and birefringence distributions as well as the input state of polarization (SOP). Further theoretical predictions show that, in φ-OTDR, the common optical phase depends on only the local birefringence in the first half of the fiber section, which is occupied by the sensing pulse, irrelevant of the input SOP. However, the intensity of the φ-OTDR signal is not a local parameter, which depends on the input SOP and the birefringence distribution along the entire fiber section before the optical pulse. Moreover, the PDL measured in φ-OTDR is theoretically proven to be a local parameter, which is determined by the local birefringence and local optical phase distributions.

18.
Natl Sci Rev ; 11(4): nwad134, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38487492

RESUMO

Efficient detection of single optical centres in solids is essential for quantum information processing, sensing and single-photon generation applications. In this work, we use radio-frequency (RF) reflectometry to electrically detect the photoionisation induced by a single Er3+ ion in Si. The high bandwidth and sensitivity of the RF reflectometry provide sub-100-ns time resolution for the photoionisation detection. With this technique, the optically excited state lifetime of a single Er3+ ion in a Si nano-transistor is measured for the first time to be [Formula: see text]s. Our results demonstrate an efficient approach for detecting a charge state change induced by Er excitation and relaxation. This approach could be used for fast readout of other single optical centres in solids and is attractive for large-scale integrated optical quantum systems thanks to the multi-channel RF reflectometry demonstrated with frequency multiplexing techniques.

19.
Int Urogynecol J ; 35(3): 723-729, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38456894

RESUMO

INTRODUCTION AND HYPOTHESIS: Phosphodiesterase enzymes are widely distributed in female urogenital tissues. Yet, the understanding of their physiological roles and the impact of phosphodiesterase inhibitors on lower urinary tract symptoms in women remains limited. Current hypotheses are conflicting: one suggests that vasodilation might expand the periurethral vascular plexus, leading to increased urethral pressure, whereas the other proposes a relaxation of urethral musculature, resulting in decreased pressure. To further clarify this, we investigated the effect of tadalafil on the opening urethral pressure and voiding function in healthy women. METHODS: We conducted a randomized, double-blind, placebo-controlled crossover trial involving 24 healthy women. Participants were randomly assigned to receive a single dose of tadalafil (40 mg) or placebo during their initial visit and then switched to the alternative treatment during their second visit. Opening urethral pressure was measured with urethral pressure reflectometry during both resting and squeezing conditions of the pelvic floor. Subsequently, voiding parameters were recorded. RESULTS: Compared with placebo, a single dose of tadalafil significantly reduced opening urethral pressure during both resting (-6.8 cmH20; 95% confidence interval [CI], -11.8 to -1.9; p = 0.009) and squeezing conditions (-8.8 cmH20; 95% CI, -14.6 to -3.1; p = 0.005). Voiding parameters did not show significant differences (average flow rate: -0.8 ml/s [95% CI, -2.0 to 0.4; p = 0.2]; maximum flow rate: -1.7 ml/s [95% CI, -4.8 to 1.5; p = 0.3]). CONCLUSIONS: A single dose of 40 mg tadalafil moderately reduced urethral pressure in healthy women, without affecting voiding parameters. The clinical implications of this are yet to be determined.


Assuntos
Sintomas do Trato Urinário Inferior , Uretra , Feminino , Humanos , Tadalafila/farmacologia , Tadalafila/uso terapêutico , Estudos Cross-Over , Micção , Sintomas do Trato Urinário Inferior/tratamento farmacológico , Método Duplo-Cego , Carbolinas/farmacologia , Carbolinas/uso terapêutico
20.
Sensors (Basel) ; 24(4)2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38400410

RESUMO

We describe a method for reducing the cost of optical frequency domain reflectometer (OFDR) hardware by replacing two reference channels, including an auxiliary interferometer and a gas cell, with a single channel. To extract useful information, digital signal processing methods were used: digital frequency filtering, as well as empirical mode decomposition. It is shown that the presented method helps to avoid the use of an unnecessary analog-to-digital converter and photodetector, while the OFDR trace is restored by the equal frequency resampling (EFR) algorithm without loss of high resolution and with good measurement repeatability.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...