Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 845
Filtrar
1.
J Magn Reson Imaging ; 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-38994701

RESUMO

BACKGROUND: Congenital heart disease (CHD) has been linked to impaired placental and fetal brain development. Assessing the placenta and fetal brain in parallel may help further our understanding of the relationship between development of these organs. HYPOTHESIS: 1) Placental and fetal brain oxygenation are correlated, 2) oxygenation in these organs is reduced in CHD compared to healthy controls, and 3) placental structure is altered in CHD. STUDY TYPE: Retrospective case-control. POPULATION: Fifty-one human fetuses with CHD (32 male; median [IQR] gestational age [GA] = 32.0 [30.9-32.9] weeks) and 30 from uncomplicated pregnancies with normal birth outcomes (18 male; median [IQR] GA = 34.5 [31.9-36.7] weeks). FIELD STRENGTH/SEQUENCE: 1.5 T single-shot multi-echo-gradient-echo echo-planar imaging. ASSESSMENT: Masking was performed using an automated nnUnet model. Mean brain and placental T2* and quantitative measures of placental texture, volume, and morphology were calculated. STATISTICAL TESTS: Spearman's correlation coefficient for determining the association between brain and placental T2*, and between brain and placental characteristics with GA. P-values for comparing brain T2*, placenta T2*, and placental characteristics between groups derived from ANOVA. Significance level P < 0.05. RESULTS: There was a significant positive association between placental and fetal brain T2* (⍴ = 0.46). Placental and fetal brain T2* showed a significant negative correlation with GA (placental T2* ⍴ = -0.65; fetal brain T2* ⍴ = -0.32). Both placental and fetal brain T2* values were significantly reduced in CHD, after adjusting for GA (placental T2*: control = 97 [±24] msec, CHD = 83 [±23] msec; brain T2*: control = 218 [±26] msec, CHD = 202 [±25] msec). Placental texture and morphology were also significantly altered in CHD (Texture: control = 0.84 [0.83-0.87], CHD = 0.80 [0.78-0.84]; Morphology: control = 9.9 [±2.2], CHD = 10.8 [±2.0]). For all fetuses, there was a significant positive association between placental T2* and placental texture (⍴ = 0.46). CONCLUSION: Placental and fetal brain T2* values are associated in healthy fetuses and those with CHD. Placental and fetal brain oxygenation are reduced in CHD. Placental appearance is significantly altered in CHD and shows associations with placental oxygenation, suggesting altered placental development and function may be related. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 3.

2.
J Neurol ; 2024 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-39003428

RESUMO

BACKGROUND AND OBJECTIVES: In multiple sclerosis (MS), slowly expanding lesions were shown to be associated with worse disability and prognosis. Their timely detection from cross-sectional data at early disease stages could be clinically relevant to inform treatment planning. Here, we propose to use multiparametric, quantitative MRI to allow a better cross-sectional characterization of lesions with different longitudinal phenotypes. METHODS: We analysed T1 and T2 relaxometry maps from a longitudinal cohort of MS patients. Lesions were classified as enlarging, shrinking, new or stable based on their longitudinal volumetric change using a newly developed automated technique. Voxelwise deviations were computed as z-scores by comparing individual patient data to T1, T2 and T2/T1 normative values from healthy subjects. We studied the distribution of microstructural properties inside lesions and within perilesional tissue. RESULTS AND CONCLUSIONS: Stable lesions exhibited the highest T1 and T2 z-scores in lesion tissue, while the lowest values were observed for new lesions. Shrinking lesions presented the highest T1 z-scores in the first perilesional ring while enlarging lesions showed the highest T2 z-scores in the same region. Finally, a classification model was trained to predict the longitudinal lesion type based on microstructural metrics and feature importance was assessed. Z-scores estimated in lesion and perilesional tissue from T1, T2 and T2/T1 quantitative maps carry discriminative and complementary information to classify longitudinal lesion phenotypes, hence suggesting that multiparametric MRI approaches are essential for a better understanding of the pathophysiological mechanisms underlying disease activity in MS lesions.

3.
Magn Reson Med ; 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38968093

RESUMO

PURPOSE: T1 mapping and T1-weighted contrasts have a complimentary but currently under utilized role in fetal MRI. Emerging clinical low field scanners are ideally suited for fetal T1 mapping. The advantages are lower T1 values which results in higher efficiency and reduced field inhomogeneities resulting in a decreased requirement for specialist tools. In addition the increased bore size associated with low field scanners provides improved patient comfort and accessibility. This study aims to demonstrate the feasibility of fetal brain T1 mapping at 0.55T. METHODS: An efficient slice-shuffling inversion-recovery echo-planar imaging (EPI)-based T1-mapping and postprocessing was demonstrated for the fetal brain at 0.55T in a cohort of 38 fetal MRI scans. Robustness analysis was performed and placental measurements were taken for validation. RESULTS: High-quality T1 maps allowing the investigation of subregions in the brain were obtained and significant correlation with gestational age was demonstrated for fetal brain T1 maps ( p < 0 . 05 $$ p<0.05 $$ ) as well as regions-of-interest in the deep gray matter and white matter. CONCLUSIONS: Efficient, quantitative T1 mapping in the fetal brain was demonstrated on a clinical 0.55T MRI scanner, providing foundations for both future research and clinical applications including low-field specific T1-weighted acquisitions.

4.
Magn Reson Imaging ; 112: 100-106, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38971266

RESUMO

We aimed to determine the intra-site repeatability and cross-site reproducibility of T1 and T2* relaxation times and quantitative susceptibility (χ) values obtained through quantitative parameter mapping (QPM) at 3 T. This prospective study included three 3-T scanners with the same hardware and software platform at three sites. The brains of twelve healthy volunteers were scanned three times using QPM at three sites. Intra-site repeatability and cross-site reproducibility were evaluated based on voxel-wise and region-of-interest analyses. The within-subject coefficient of variation (wCV), within-subject standard deviation (wSD), linear regression, Bland-Altman plot, and intraclass correlation coefficient (ICC) were used for evaluation. The intra-site repeatability wCV was 11.9 ± 6.86% for T1 and 3.15 ± 0.03% for T2*, and wSD of χ at 3.35 ± 0.10 parts per billion (ppb). Intra-site ICC(1,k) values for T1, T2*, and χ were 0.878-0.904, 0.972-0.976, and 0.966-0.972, respectively, indicating high consistency within the same scanner. Linear regression analysis revealed a strong agreement between measurements from each site and the site-average measurement, with R-squared values ranging from 0.79 to 0.83 for T1, 0.94-0.95 for T2*, and 0.95-0.96 for χ. The cross-site wCV was 13.4 ± 5.47% for T1 and 3.69 ± 2.25% for T2*, and cross-site wSD of χ at 4.08 ± 3.22 ppb. The cross-site ICC(2,1) was 0.707, 0.913, and 0.902 for T1, T2*, and χ, respectively. QPM provides T1, T2*, and χ values with an intra-site repeatability of <12% and cross-site reproducibility of <14%. These findings may contribute to the development of multisite studies.

5.
MAGMA ; 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39042205

RESUMO

OBJECTIVE: Quantitative parameter mapping conventionally relies on curve fitting techniques to estimate parameters from magnetic resonance image series. This study compares conventional curve fitting techniques to methods using neural networks (NN) for measuring T2 in the prostate. MATERIALS AND METHODS: Large physics-based synthetic datasets simulating T2 mapping acquisitions were generated for training NNs and for quantitative performance comparisons. Four combinations of different NN architectures and training corpora were implemented and compared with four different curve fitting strategies. All methods were compared quantitatively using synthetic data with known ground truth, and further compared on in vivo test data, with and without noise augmentation, to evaluate feasibility and noise robustness. RESULTS: In the evaluation on synthetic data, a convolutional neural network (CNN), trained in a supervised fashion using synthetic data generated from naturalistic images, showed the highest overall accuracy and precision amongst the methods. On in vivo data, this best performing method produced low-noise T2 maps and showed the least deterioration with increasing input noise levels. DISCUSSION: This study showed that a CNN, trained with synthetic data in a supervised manner, may provide superior T2 estimation performance compared to conventional curve fitting, especially in low signal-to-noise regions.

6.
Nano Lett ; 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39012318

RESUMO

Chronic obstructive pulmonary disease (COPD), the third leading cause of death worldwide, is caused by chronic exposure to toxic particles and gases, such as cigarette smoke. Free radicals, which are produced during a stress response to toxic particles, play a crucial role in disease progression. Measuring these radicals is difficult since the complex mixture of chemicals within cigarette smoke interferes with radical detection. We used a new quantum sensing technique called relaxometry to measure free radicals with nanoscale resolution on cells from COPD patients and healthy controls exposed to cigarette smoke extract (CSE) or control medium. Epithelial cells from COPD patients display a higher free radical load than those from healthy donors and are more vulnerable to CSE. We show that epithelial cells of COPD patients are more susceptible to the damaging effects of cigarette smoke, leading to increased release of free radicals.

7.
Biomater Adv ; 162: 213927, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38917649

RESUMO

Metals are widely utilized as implant materials for bone fixtures as well as stents. Biodegradable versions of these implants are highly desirable since patients do not have to undergo a second surgery for the materials to be removed. Attractive options for such materials are zinc silver alloys since they also offer the benefit of being antibacterial. However, it is important to investigate the effect of the degradation products of such alloys on the surrounding cells, taking into account silver cytotoxicity. Here we investigated zinc alloyed with 1 % of silver (Zn1Ag) and how differently concentrated extracts (1 %-100 %) of this material impact human umbilical vein endothelial cells (HUVECs). More specifically, we focused on free radical generation and oxidative stress as well as the impact on cell viability. To determine free radical production we used diamond-based quantum sensing as well as conventional fluorescent assays. The viability was assessed by observing cell morphology and the metabolic activity via the MTT assay. We found that 1 % and 10 % extracts are well tolerated by the cells. However, at higher extract concentrations we observed severe impact on cell viability and oxidative stress. We were also able to show that quantum sensing was able to detect significant free radical generation even at the lowest tested concentrations.


Assuntos
Ligas , Sobrevivência Celular , Células Endoteliais da Veia Umbilical Humana , Nanodiamantes , Estresse Oxidativo , Zinco , Humanos , Ligas/química , Sobrevivência Celular/efeitos dos fármacos , Células Endoteliais da Veia Umbilical Humana/efeitos dos fármacos , Estresse Oxidativo/efeitos dos fármacos , Nanodiamantes/química , Prata/toxicidade , Prata/química , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Radicais Livres/metabolismo , Teste de Materiais/métodos , Implantes Absorvíveis/efeitos adversos
8.
Food Res Int ; 190: 114566, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38945597

RESUMO

This study assessed water relaxometry of beef exposed to different ageing techniques by examining the inner and surface regions using time-domain nuclear magnetic resonance (TD-NMR) relaxometry. Beef strip loins were aged under vacuum (Wet), under vacuum using moisture absorbers (Abs), under vacuum using moisture absorbers and with mechanical tenderisation (AbsTend), or without any packaging (Dry). The ageing technique significantly influenced various meat parameters, including dehydration, total loss, and the moisture content of the meat surface. The transverse (T2) relaxation times provided a more sensitive indicator of the changes in meat water relaxometry than the longitudinal (T1) relaxation times. The Dry samples exhibited distinct differences in the T2 signals between the surface and inner regions of the meat. In particular, for the inner region, there were significant differences in signal areas between the Wet and Dry samples, and the Abs and AbsTend samples were positioned closely together between the Dry and Wet samples. The principal component analysis supported these findings: it indicated some differentiation among the ageing techniques in the score plot, but the differentiation was more pronounced when analysing the surface region. Additionally, there was a strong correlation between dehydration and the T2 values, leading to a clustering of the samples based on the ageing technique. The overlap between the Abs and AbsTend samples, situated between the Dry and Wet samples, suggests the potential of these treatments to produce meat with properties that are intermediate to Wet and Dry meat. Furthermore, tenderisation did not lead to greater dehydration.


Assuntos
Manipulação de Alimentos , Espectroscopia de Ressonância Magnética , Água , Água/química , Animais , Bovinos , Espectroscopia de Ressonância Magnética/métodos , Manipulação de Alimentos/métodos , Vácuo , Carne Vermelha/análise , Fatores de Tempo , Carne/análise , Análise de Componente Principal
9.
J Biol Phys ; 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38935192

RESUMO

Bone is a complex tissue that fulfills the role of a resistance structure. This quality is most commonly assessed by bone densitometry, but bone strength may not only be related to bone mineral density but also to the preservation of bone cytoarchitectonics. The study included two groups of rats, ovariectomized and non-ovariectomized. Each group was divided into three batches: control, simvastatin-treated, and fenofibrate-treated. In the ovariectomized group, hypolipidemic treatment was instituted at 12 weeks post ovariectomy. One rat from each of the 6 batches was sacrificed 8 weeks after the start of treatment in the group. The experimental study was performed using a Bruker Minispec mq 20 spectrometer operating at a frequency of 20 MHz, subsequently also performed by 1H T2-T2 molecular exchange maps. The results were represented by T2-T2 molecular exchange maps that showed, comparatively, both pore size and their interconnectivity at the level of the femoral epiphysis, being able to evaluate both the effect of estrogen on bone tissue biology and the effect of the lipid-lowering medication, simvastatin, and fenofibrate, in both the presence and absence of estrogen. T2-T2 molecular exchange maps showed that the absence of estrogen results in an increase in bone tissue pore size and interconnectivity. In the presence of estrogen, lipid-lowering medication, both simvastatin and fenofibrate alter bone tissue cytoarchitectonics by reducing pore interconnectivity. In the absence of estrogen, fenofibrate improves bone tissue cytoarchitectonics, the T2-T2 molecular exchange map being similar to that of non-osteoporotic bone tissue.

10.
Molecules ; 29(11)2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38893297

RESUMO

1H fast field-cycling and time-domain nuclear magnetic resonance relaxometry studies have been performed for 15 samples of sugar of different kinds and origins (brown, white, cane, beet sugar). The extensive data set, including results for crystal sugar and sugar/water mixtures, has been thoroughly analyzed, with a focus on identifying relaxation contributions associated with the solid and liquid fractions of the systems and non-exponentiality of the relaxation processes. It has been observed that 1H spin-lattice relaxation rates for crystal sugar (solid) vary between 0.45 s-1 and 0.59 s-1, and the relaxation process shows only small deviations from exponentiality (a quantitative measure of the exponentiality has been provided). The 1H spin-lattice relaxation process for sugar/water mixtures has turned out to be bi-exponential, with the relaxation rates varying between about 13 s-1-17 s-1 (for the faster component) and about 2.1 s-1-3.5 s-1 (for the slower component), with the ratio between the amplitudes of the relaxation contributions ranging between 2.8 and 4.2. The narrow ranges in which the parameters vary make them a promising marker of the quality and authenticity of sugar.

11.
Diagnostics (Basel) ; 14(11)2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38893596

RESUMO

BACKGROUND: Endometriosis-associated ovarian cancer (EAOC) is a well-known type of cancer that arises from ovarian endometrioma (OE). OE contains iron-rich fluid in its cysts due to repeated hemorrhages in the ovaries. However, distinguishing between benign and malignant tumors can be challenging. We conducted a retrospective study on magnetic resonance (MR) relaxometry of cyst fluid to distinguish EAOC from OE and reported that this method showed good accuracy. The purpose of this study is to evaluate the accuracy of a non-invasive method in re-evaluating pre-surgical diagnosis of malignancy by a prospective multicenter cohort study. METHODS: After the standard diagnosis process, the R2 values were obtained using a 3T system. Data on the patients were then collected through the Case Report Form (CRF). Between December 2018 and March 2023, six hospitals enrolled 109 patients. Out of these, 81 patients met the criteria required for the study. RESULTS: The R2 values calculated using MR relaxometry showed good discriminating ability with a cut-off of 15.74 (sensitivity 80.6%, specificity 75.0%, AUC = 0.750, p < 0.001) when considering atypical or borderline tumors as EAOC. When atypical and borderline cases were grouped as OE, EAOC could be distinguished with a cut-off of 16.87 (sensitivity 87.0%, specificity 61.1%). CONCLUSIONS: MR relaxometry has proven to be an effective tool for discriminating EAOC from OE. Regular use of this method is expected to provide significant insights for clinical practice.

12.
bioRxiv ; 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38895252

RESUMO

Purpose: To compare the performance of multi-echo (ME) and time-division multiplexing (TDM) sequences for accelerated relaxation-diffusion MRI (rdMRI) acquisition and to examine their reliability in estimating accurate rdMRI microstructure measures. Method: The ME, TDM, and the reference single-echo (SE) sequences with six echo times (TE) were implemented using Pulseq with single-band (SB-) and multi-band 2 (MB2-) acceleration factors. On a diffusion phantom, the image intensities of the three sequences were compared, and the differences were quantified using the normalized root mean squared error (NRMSE). For the in-vivo brain scan, besides the image intensity comparison and T2-estimates, different methods were used to assess sequence-related effects on microstructure estimation, including the relaxation diffusion imaging moment (REDIM) and the maximum-entropy relaxation diffusion distribution (MaxEnt-RDD). Results: TDM performance was similar to the gold standard SE acquisition, whereas ME showed greater biases (3-4× larger NRMSEs for phantom, 2× for in-vivo). T2 values obtained from TDM closely matched SE, whereas ME sequences underestimated the T2 relaxation time. TDM provided similar diffusion and relaxation parameters as SE using REDIM, whereas SB-ME exhibited a 60% larger bias in the map and on average 3.5× larger bias in the covariance between relaxation-diffusion coefficients. Conclusion: Our analysis demonstrates that TDM provides a more accurate estimation of relaxation-diffusion measurements while accelerating the acquisitions by a factor of 2 to 3.

13.
Comput Biol Med ; 178: 108753, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38897148

RESUMO

The Instantaneous Signal Loss Simulation (InSiL) model is a promising alternative to the classical mono-exponential fitting of the Modified Look-Locker Inversion-recovery (MOLLI) sequence in cardiac T1 mapping applications, which achieves better accuracy and is less sensitive to heart rate (HR) variations. Classical non-linear least squares (NLLS) estimation methods require some parameters of the model to be fixed a priori in order to give reliable T1 estimations and avoid outliers. This introduces further bias in the estimation, reducing the advantages provided by the InSiL model. In this paper, a novel Bayesian estimation method using a hierarchical model is proposed to fit the parameters of the InSiL model. The hierarchical Bayesian modeling has a shrinkage effect that works as a regularizer for the estimated values, by pulling spurious estimated values toward the group-mean, hence reducing greatly the number of outliers. Simulations, physical phantoms, and in-vivo human cardiac data have been used to show that this approach estimates accurately all the InSiL parameters, and achieve high precision estimation of the T1 compared to the classical MOLLI model and NLLS InSiL estimation.


Assuntos
Teorema de Bayes , Coração , Humanos , Coração/diagnóstico por imagem , Coração/fisiologia , Modelos Cardiovasculares , Simulação por Computador , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Processamento de Imagem Assistida por Computador/métodos
14.
J Dairy Sci ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38851570

RESUMO

The aim of the study was to enquire to which extend 1H spin-lattice Nuclear Magnetic Resonance relaxometry data collected over a broad range of resonance frequencies (from 10kHz to 10MHz) have the potential to be used for assessing quality and authenticity of different categories of cheese. The following cheeses were selected mozzarella (M), processed cheese (C), pizza cheese (P) and pizza cheese with modified fat phase (PC), low-fat cheese (LF) and long ripened cheese (R). The cheeses from different production plants (1,2,3) and various cheese production batches (a, b, c) were used in the study. The samples from each group were subjected to instrumental composition analysis (FoodScan analyzer type 78810, FOSS, Hillerod, Denmark), water activity assessment (AQUA LAB 4TEV analyzer, type S40001855, USA) and determination of the NMRD profiles (SMARtracer FFC relaxometer, Stelar S.r.l, Italy, 2017). The state and dynamics of water present in products as free and bound water largely determines the properties of food products, including cheeses. NMR relaxometry studies of cheese enable to reveal relaxation features characteristic of specific categories of cheese. Consequently, the studies can be treated as a step toward exploiting NMR relaxometry for accessing quality and authenticity of cheese. It was shown that at low resonance frequencies, the lower the moisture, the larger the relaxation rate. The durability and quality of cheeses depend on the presence and condition of water, so it is necessary to find a relationship between the presence, condition and mobility of water in cheeses, to increase and improve the quality and extend the shelf life.

15.
Front Neurol ; 15: 1335408, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38765263

RESUMO

Objectives: Multiple sclerosis (MS) is a demyelinating disorder of the central nervous system. Increasing evidence indicates additional peripheral nerve involvement in early and chronic disease stages. To investigate the evolution of peripheral nerve changes in patients first diagnosed with MS using quantitative MR neurography. Materials and methods: This prospective study included 19 patients with newly diagnosed MS according to the revised McDonald criteria (16 female, mean 30.2 ± 7.1 years) and 19 age-/sex-matched healthy volunteers. High-resolution 3 T MR neurography of the sciatic nerve using a quantitative T2-relaxometry sequence was performed, which yielded the biomarkers of T2 relaxation time (T2app) and proton spin density (PSD). Follow-up scans of patients were performed after median of 12 months (range 7-16). Correlation analyses considered clinical symptoms, intrathecal immunoglobulin synthesis, nerve conduction study, and lesion load on brain and spine MRI. Results: Patients showed increased T2app and decreased PSD compared to healthy controls at initial diagnosis and follow-up (p < 0.001 each). Compared to the initial scan, T2app further increased in patients at follow-up (p = 0.003). PSD further declined by at least 10% in 9/19 patients and remained stable in another 9/19 patients. Correlation analyses did not yield significant results. Conclusion: Peripheral nerve involvement in MS appears at initial diagnosis and continues to evolve within 1 year follow-up with individual dynamics. Quantitative MRN provides non-invasive biomarkers to detect and monitor peripheral nerve changes in MS.

16.
Neuroradiology ; 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38771548

RESUMO

PURPOSE: How to measure brain globotriaosylceramide (Gb3) accumulation in Fabry Disease (FD) patients in-vivo is still an open challenge. The objective of this study is to provide a quantitative, non-invasive demonstration of this phenomenon using quantitative MRI (qMRI). METHODS: In this retrospective, monocentric cross-sectional study conducted from November 2015 to July 2018, FD patients and healthy controls (HC) underwent an MRI scan with a relaxometry protocol to compute longitudinal relaxation rate (R1) maps to evaluate gray (GM) and white matter (WM) lipid accumulation. In a subgroup of 22 FD patients, clinical (FAbry STabilization indEX -FASTEX- score) and biochemical (residual α-galactosidase activity) variables were correlated with MRI data. Quantitative maps were analyzed at both global ("bulk" analysis) and regional ("voxel-wise" analysis) levels. RESULTS: Data were obtained from 42 FD patients (mean age = 42.4 ± 12.9, M/F = 16/26) and 49 HC (mean age = 42.3 ± 16.3, M/F = 28/21). Compared to HC, FD patients showed a widespread increase in R1 values encompassing both GM (pFWE = 0.02) and WM (pFWE = 0.02) structures. While no correlations were found between increased R1 values and FASTEX score, a significant negative correlation emerged between residual enzymatic activity levels and R1 values in GM (r = -0.57, p = 0.008) and WM (r = -0.49, p = 0.03). CONCLUSIONS: We demonstrated the feasibility and clinical relevance of non-invasively assessing cerebral Gb3 accumulation in FD using MRI. R1 mapping might be used as an in-vivo quantitative neuroimaging biomarker in FD patients.

17.
MAGMA ; 2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38733487

RESUMO

OBJECTIVE: To prepare and analyze soy-lecithin-agar gels for non-toxic relaxometry phantoms with tissue-like relaxation times at 3T. METHODS: Phantoms mimicking the relaxation times of various tissues (gray and white matter, kidney cortex and medulla, spleen, muscle, liver) were built and tested with a clinical 3T whole-body MR scanner. Simple equations were derived to calculate the appropriate concentrations of soy lecithin and agar in aqueous solutions to achieve the desired relaxation times. Phantoms were tested for correspondence between measurements and calculated T1 and T2 values, reproducibility, spatial homogeneity, and temporal stability. T1 and T2 mapping techniques and a 3D T1-weighted sequence with high spatial resolution were applied. RESULTS: Except for the liver relaxation phantom, all phantoms were successfully and reproducibly produced. Good agreement was found between the targeted and measured relaxation times. The percentage deviations from the targeted relaxation times were less than 3% for T1 and less than 6.5% for T2. In addition, the phantoms were homogeneous and had little to no air bubbles. However, the phantoms were unstable over time: after a storage period of 4 weeks, mold growth and also changes in relaxation times were detected in almost all phantoms. CONCLUSION: Soy-lecithin-agar gels are a non-toxic material for the construction of relaxometry phantoms with tissue-like relaxation times. They are easy to prepare, inexpensive and allow independent adjustment of T1 and T2. However, there is still work to be done to improve the long-term stability of the phantoms.

18.
Magn Reson Med ; 92(2): 715-729, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38623934

RESUMO

PURPOSE: We propose a quantitative framework for motion-corrected T2 fetal brain measurements in vivo and validate the single-shot fast spin echo (SS-FSE) sequence to perform these measurements. METHODS: Stacks of two-dimensional SS-FSE slices are acquired with different echo times (TE) and motion-corrected with slice-to-volume reconstruction (SVR). The quantitative T2 maps are obtained by a fit to a dictionary of simulated signals. The sequence is selected using simulated experiments on a numerical phantom and validated on a physical phantom scanned on a 1.5T system. In vivo quantitative T2 maps are obtained for five fetuses with gestational ages (GA) 21-35 weeks on the same 1.5T system. RESULTS: The simulated experiments suggested that a TE of 400 ms combined with the clinically utilized TEs of 80 and 180 ms were most suitable for T2 measurements in the fetal brain. The validation on the physical phantom confirmed that the SS-FSE T2 measurements match the gold standard multi-echo spin echo measurements. We measured average T2s of around 200 and 280 ms in the fetal brain grey and white matter, respectively. This was slightly higher than fetal T2* and the neonatal T2 obtained from previous studies. CONCLUSION: The motion-corrected SS-FSE acquisitions with varying TEs offer a promising practical framework for quantitative T2 measurements of the moving fetus.


Assuntos
Encéfalo , Feto , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Humanos , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Feminino , Gravidez , Feto/diagnóstico por imagem , Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Idade Gestacional , Reprodutibilidade dos Testes , Simulação por Computador , Interpretação de Imagem Assistida por Computador/métodos , Movimento (Física)
19.
Magn Reson Med ; 92(3): 1263-1276, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38650351

RESUMO

PURPOSE: Widening the availability of fetal MRI with fully automatic real-time planning of radiological brain planes on 0.55T MRI. METHODS: Deep learning-based detection of key brain landmarks on a whole-uterus echo planar imaging scan enables the subsequent fully automatic planning of the radiological single-shot Turbo Spin Echo acquisitions. The landmark detection pipeline was trained on over 120 datasets from varying field strength, echo times, and resolutions and quantitatively evaluated. The entire automatic planning solution was tested prospectively in nine fetal subjects between 20 and 37 weeks. A comprehensive evaluation of all steps, the distance between manual and automatic landmarks, the planning quality, and the resulting image quality was conducted. RESULTS: Prospective automatic planning was performed in real-time without latency in all subjects. The landmark detection accuracy was 4.2 ± $$ \pm $$ 2.6 mm for the fetal eyes and 6.5 ± $$ \pm $$ 3.2 for the cerebellum, planning quality was 2.4/3 (compared to 2.6/3 for manual planning) and diagnostic image quality was 2.2 compared to 2.1 for manual planning. CONCLUSIONS: Real-time automatic planning of all three key fetal brain planes was successfully achieved and will pave the way toward simplifying the acquisition of fetal MRI thereby widening the availability of this modality in nonspecialist centers.


Assuntos
Encéfalo , Feto , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Encéfalo/diagnóstico por imagem , Encéfalo/embriologia , Imageamento por Ressonância Magnética/métodos , Feminino , Gravidez , Feto/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Aprendizado Profundo , Diagnóstico Pré-Natal/métodos , Estudos Prospectivos , Imagem Ecoplanar/métodos , Algoritmos , Interpretação de Imagem Assistida por Computador/métodos
20.
Magn Reson Med ; 92(3): 1177-1188, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38558167

RESUMO

PURPOSE: The anisotropy of R2 and R1ρ relaxation rates in articular cartilage contains information about the collagenous structure of the tissue. Here we determine and study the anisotropic and isotropic components of T2 and T1ρ relaxation parameters in articular cartilage with a clinical 3T MRI device. Furthermore, a visual representation of the topographical variation in anisotropy is given via anisotropy mapping. METHODS: Eight bovine stifle joints were imaged at 22 orientations with respect to the main magnetic field using T2, continuous-wave (CW) T1ρ, and adiabatic T1ρ mapping sequences. Relaxation rates were separated into isotropic and anisotropic relaxation components using a previously established relaxation anisotropy model. Pixel-wise anisotropy values were determined from the relaxation-time maps using Michelson contrast. RESULTS: The relaxation rates obtained from the samples displayed notable variation depending on the sample orientation, magnetization preparation, and cartilage layer. R2 demonstrated significant anisotropy, whereas CW-R1ρ (300 Hz) and CW-R1ρ (500 Hz) displayed a low degree of anisotropy. Adiabatic R1ρ was largely isotropic. In the deep cartilage regions, relaxation rates were generally faster and more anisotropic than in the cartilage closer to the tissue surface. The isotropic relaxation rate components were found to have similar values regardless of measurement sequence. CONCLUSIONS: The fitted relaxation model for T2 and T1ρ demonstrated varying amounts anisotropy, depending on magnetization preparation, and studied the articular cartilage layer. Anisotropy mapping of full joints showed varying amounts of anisotropy depending on the quantitative MRI parameter and topographical location, and in the case of T2, showed systematic changes in anisotropy across cartilage depth.


Assuntos
Cartilagem Articular , Imageamento por Ressonância Magnética , Cartilagem Articular/diagnóstico por imagem , Animais , Anisotropia , Imageamento por Ressonância Magnética/métodos , Bovinos , Reprodutibilidade dos Testes , Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...