Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 18.658
Filtrar
1.
Front Bioeng Biotechnol ; 12: 1385986, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38983600

RESUMO

Objective: 1. To assess the Inter-rater reliability and test-retest reliability of FPI-6 total score and individual scores in static foot posture evaluation among elderly female patients with knee osteoarthritis (KOA), aiming to establish the reliability of the FPI-6 scale. 2. To investigate the disparity between dominant and non-dominant quadriceps characteristics in elderly female KOA patients, as well as explore the correlation between quadriceps characteristics and abnormal foot posture, thereby offering novel insights for the prevention and treatment of KOA. Methods: The study enrolled a total of 80 lower legs of 40 participants (all female) with unilateral or bilateral KOA, who were assessed by two raters at three different time points. The inter-rater and test-retest reliability of the FPI-6 was evaluated using the intra-class correlation coefficient (ICC), while the absolute reliability of FPI-6 was examined using the standard error of measurement (SEM), minimum detectable change (MDC), and Bland-Altman analysis. The internal consistency of FPI-6 was assessed using Spearman's correlation coefficient. Additionally, MyotonPRO was employed to assess quadriceps muscle tone and stiffness in all participants, and the association between quadriceps muscle tone/stiffness and the total score of FPI-6 was analyzed. Result: Our study found excellent inter-rater and test-retest reliability (ICC values of 0.923 and 0.931, respectively) for the FPI-6 total score, as well as good to excellent reliability (ICC values ranging from 0.680 to 0.863 and 0.739-0.883) for individual items. The SEM and MDC values for the total score of FPI-6 among our study inter-rater were 0.78 and 2.15, respectively. and the SEM and MDC values for the test-retest total score of FPI-6 were found to be 0.76 and 2.11, respectively. Furthermore, the SEM and MDC values between inter-rater and test-retest across six individual items ranged from 0.30 to 0.56 and from 0.84 to 1.56. The Bland-Altman plots and respective 95% LOA showed no evidence of systematic bias. In terms of the mechanical properties of the quadriceps on both sides, the muscle tone and stiffness of rectus femoris (RF), vastus medialis (VM), and vastus lateralis (VL) were significantly higher in the non-dominant leg compared to the dominant leg. Additionally, in the non-dominant leg, there was a significant positive correlation between the muscle tone and stiffness of VM, VL, RF and the total score of FPI-6. However, in the dominant leg, only VM's muscle tone and stiffness showed a significant positive correlation with the total score of FPI-6. Conclusion: The reliability of the FPI-6 total score and its six individual items was good to excellent. Our findings offer a straightforward and dependable approach for researchers to assess foot posture in elderly female patients with KOA. Furthermore, we observed significantly greater quadriceps tension and stiffness in the non-dominant leg compared to the dominant leg. The FPI-6 total score exhibited a significant correlation with changes in quadriceps muscle performance among KOA patients. These observations regarding the relationship between changes in quadriceps muscle performance and foot posture in elderly female KOA patients may provide novel insights for disease prevention, treatment, and rehabilitation.

2.
Gastroenterol Hepatol Bed Bench ; 17(2): 198-205, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38994504

RESUMO

Aim: The aim of this study was to translate and cross-culturally adapt the Constipation Severity Instrument (CSI) and assess its reliability and validity in the Iranian Persian language with chronic functional constipation. Background: Chronic functional constipation is a common complaint characterized by a range of symptoms. The use of a validated tool adapted to the culture is an important part of the treatment process. Methods: CSI was translated into Persian language according to Beaton's guidelines. One hundred and twenty-five patients with chronic functional constipation, according to ROME IV criteria, completed the questionnaires. Face validity was assessed in two qualitative and quantitative forms (impact score), internal consistency and test-retest reliability were assessed by Cronbach's alpha coefficient and intraclass correlation coefficient (ICC), respectively. Convergent validity was assessed by correlating the total scores of the CSI and the WCSS. The floor/ ceiling effects of the questionnaire were also assessed. Results: The impact score of all questions was greater than 1.5. The Cronbach's alpha coefficient for the total score was 0.90 and the ICC was 0.90. The total score of the CSI was significantly correlated with the total score of the WCSS (Spearman's p=0.74). No floor/ceiling effects were found. Conclusion: The Persian version of the CSI is a reliable and valid tool that can be used for psychometric evaluation. Clinicians can also benefit from this questionnaire when assessing treatment outcomes in Iranian patients.

3.
Clin Rheumatol ; 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39008222

RESUMO

This study aimed to examine psychometric properties of the Adherence to Refills and Medications Scale (ARMS) in people with gout. We conducted exploratory factor analysis (EFA) and tested internal consistency (ordinal and Cronbach's alpha coefficients) and agreement (intraclass correlation coefficient (2,1)) in ARMS scores across three timepoints (baseline, 6, and 12 months) in 487 people with gout. The Kruskal-Wallis test, Spearman's rank, Kendall's tau-b correlations, and logistic regression were used to examine the criterion-related validity of the ARMS and factors associated with the ARMS. EFA suggested a one-factor structure, explaining 43.2% of total variance. High internal consistency (ordinal alpha = 0.902 at baseline) and moderate agreement in ARMS scores over time (ICCs > 0.5; p < 0.001) were observed. Lower ARMS scores (indicating better adherence) predicted achieving target serum urate (OR, 0.89; 95% CI, 0.83-0.95; p < 0.001), but not urate-lowering therapy (ULT) adherence (Proportion of Days Covered (PDC) ≥ 80%) (OR, 0.93; 95% CI, 0.81-1.05; p = 0.261). Negative correlations between ARMS and PDC were not statistically significant (Kendall's tau-b, r = - 0.126, p = 0.078; Spearman's rho = - 0.173, p < 0.073). Differences in median ARMS scores (IQR) of 16 (14-20), 13 (12-15), and 17.5 (15-21) in three groups of participants who reported (1) not taking ULT, (2) taking ULT and adherent, and (3) taking ULT but not adherent, respectively, were statistically significant (p < 0.001). Age was the only patient factor independently associated with optimal adherence (ARMS score = 12) (OR, 1.91; 95% CI, 1.50-2.43; p < 0.001). The ARMS is a reliable and valid measure of medication adherence behaviours in people with gout, justifying its use in gout medication adherence research.

4.
Adv Sci (Weinh) ; : e2400061, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39005232

RESUMO

Although white matter (WM) accounts for nearly half of adult brain, its wiring diagram is largely unknown. Here, an approach is developed to construct WM networks by estimating interregional morphological similarity based on structural magnetic resonance imaging. It is found that morphological WM networks showed nontrivial topology, presented good-to-excellent test-retest reliability, accounted for phenotypic interindividual differences in cognition, and are under genetic control. Through integration with multimodal and multiscale data, it is further showed that morphological WM networks are able to predict the patterns of hamodynamic coherence, metabolic synchronization, gene co-expression, and chemoarchitectonic covariance, and associated with structural connectivity. Moreover, the prediction followed WM functional connectomic hierarchy for the hamodynamic coherence, is related to genes enriched in the forebrain neuron development and differentiation for the gene co-expression, and is associated with serotonergic system-related receptors and transporters for the chemoarchitectonic covariance. Finally, applying this approach to multiple sclerosis and neuromyelitis optica spectrum disorders, it is found that both diseases exhibited morphological dysconnectivity, which are correlated with clinical variables of patients and are able to diagnose and differentiate the diseases. Altogether, these findings indicate that morphological WM networks provide a reliable and biologically meaningful means to explore WM architecture in health and disease.

5.
Brain Spine ; 4: 102850, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39005582

RESUMO

Introduction: Pressure reactivity index (PRx) is used for continuous monitoring of cerebrovascular reactivity in traumatic brain injury (TBI). However, PRx has a noisy character. Oscillations in arterial blood pressure (ABP) introduced by cyclic positive end-expiratory pressure adjustment, can make PRx more reliable. However, if oscillations are introduced by the cycling process of an anti-decubitus-mattress the effect on PRx is confounding, as they affect directly also intracranial pressure (ICP). In our routine monitoring in TBI patients we noticed periods of highly regular, slow, spontaneous oscillations in ABP and ICP signals. Research question: We set out to explore the nature of these oscillations and establish if PRx remains reliable during the oscillations. Materials and methods: 10 TBI patients' recordings with oscillations in ICP and ABP were analysed. We computed PRx, PRx variability (hourly-average of standard-deviation, SD), phase-shift and coherence between ABP and ICP in the slow frequency range. Metrics were compared between oscillation and peri-oscillation periods. Results: During oscillations (frequency 0.006 ± 0.002Hz), a significantly lower variability of PRx (SD 0.185vs0.242) and higher coherence ABP-ICP (0.618 ± 0.09 vs 0.534 ± 0.09) were observed. No external oscillations sources could be identified. 34 out of 48 events showed signs of 'active' transmission associated with negative PRx, indicating a potential positive impact on PRx reliability. Discussion and conclusions: Spontaneous oscillations observed in ABP and ICP signals were found to enhance rather than confound PRx reliability. Further research is warranted to elucidate the nature of these oscillations and develop strategies to leverage them for enhancing PRx reliability in TBI monitoring.

6.
PeerJ ; 12: e17658, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39006011

RESUMO

Background: Vertical jumping is an important evaluation tool to measure muscle strength and power as well as lower limb symmetry. It is of practical importance and value to develop and utilize a portable and low-cost mobile application (APP) to evaluate jumping. The "My Jump 2" app is an iPhone camera-based application for measuring jumping movements, which is applied to the countermovement jump (CMJ) vertical jumps of the lower limbs of athletes in different sports. The validity of this application and previous versions applied to different forms of vertical jump tests has been preliminarily demonstrated in different population, which has an obvious progress in research. Therefore, the reliability and validity of the jump height, time of flight parameters and symmetry of the CMJ vertical jump of athletes in different sports are needed to be verified by more experiments. Purpose: The purpose of this study is to verify whether "My Jump 2" can effectively and reliably assess jump height, flight practice and lower limb symmetry in CMJAM (countermovement jump free arm) tests in fencing, swimming and diving athletes. Methods: Seventy-nine fencers, swimmers and divers with training experience participated in this study. They completed a total of three CMJAM vertical jump and lower limb symmetry tests in 1 day, while being assessed by using the "My Jump 2" application and a force platform. The intra-group correlation coefficient (ICC) was used to verify reliability, while the Cronbach's alpha and coefficient of variation (CV%) was used to analyze the stability of the CMJAM vertical jump test over three jumps. The Pearson correlation coefficient was used to verify the strength of the relationship between methods (i.e., concurrent validity), and the Bland-Altman plot was used to represent consistency, meanwhile, the t-test was used to determine the systematic bias between methods. Results: Compared with the force platform, the cumulative height values of the total number of jumps (r = 0.999; p = 0.000), the cumulative time to vacate (r = 0.999; p = 0.000) for the CMJAM test obtained by the "My Jump 2" application, the height (ICC = 0.999-1, p = 0.000), the time to vacate flight (ICC = 0.999-1, p = 0.000), contact time symmetry (ICC = 0.976-0.994, p = 0.000), and flight time symmetry (ICC = 0.921-0.982, p = 0.000), respectively. Showed high correlation between the results of "my jump 2" app and the force platform. Conclusion: The "My Jump 2" application is a valid tool to assess CMJAM vertical jump and lower limb symmetry in fencing, swimming and diving athletes with training experience.


Assuntos
Atletas , Humanos , Reprodutibilidade dos Testes , Masculino , Feminino , Adulto , Adulto Jovem , Força Muscular/fisiologia , Teste de Esforço/métodos , Teste de Esforço/instrumentação , Aplicativos Móveis , Esportes/fisiologia , Extremidade Inferior/fisiologia , Desempenho Atlético/fisiologia
7.
J Clin Nurs ; 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39007220

RESUMO

AIM: To develop the nurses' attitudes towards use of a telehealth scale (NATUTS) and evaluate its psychometric properties. DESIGN: This methodological study involved two stages: the development of the NATUTS and the testing of the psychometric properties of NATUTS. We followed STROBE guidelines when reporting the study (File S1). METHODS: Items for NATUTS were created using evidence from the literature and presented to eight experts. The scale was tested in a methodological study conducted through a face-to-face survey with nurses working in outpatient and inpatient units of a tertiary hospital in Türkiye. Psychometric properties of the scale, such as structural validity, content validity and internal consistency reliability, were tested. The sample, consisting of 630 nurses, was divided into two separate random groups. Exploratory factor analysis was conducted with the data of the first 330 people, and confirmatory factor analysis was conducted with the data of the remaining 300 people. RESULTS: A 19-item, three-factor structure (Satisfaction, Rejection, Development) was obtained in the newly developed scale. In NATUTS, Factor 1 (α = .93), Factor 2 (α = .86) and Factor 3 (α = .87) measured 64.4% of the total variance. The entire 19-item acceptability survey showed good internal consistency. NATUTS is a brief survey based on research evidence validated in a large Turkish sample. CONCLUSION: Findings show that NATUTS has acceptable content and structural validity and is reliable in measuring nurses' attitudes towards the use of telehealth. Further research can be conducted to develop the scale and strengthen its validity. PATIENT OR PUBLIC CONTRIBUTION: No Patient or Public Contribution.

8.
Phys Occup Ther Pediatr ; : 1-14, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39007754

RESUMO

AIM: The Test of Gross Motor Development Third Edition (TGMD-3) is used to assess the development of fundamental movement skills in children from 3 to 10 years old. This study aimed to evaluate the intra-rater, inter-rater, and test-retest reliability and to determine the minimal detectable change (MDC) value of the TGMD-3 in children with developmental coordination disorder (DCD). METHODS: The TGMD-3 was administered to 20 children with DCD. The child's fundamental movement skills were recorded using a digital video camera. Reliability was assessed at two occasions by three raters using the generalizability theory. RESULTS: The TGMD-3 demonstrates good inter-rater reliability for the locomotor skills subscale, the ball skills subscale, and the total score (φ = 0.77 - 0.91), while the intra-rater reliability was even higher (φ = 0.94 - 0.97). Test-retest reliability was also shown to be good (φ = 0.79-0.93). The MDC95 was determined to be 10 points. CONCLUSION: This study provides evidence that the TGMD-3 is a reliable test when used to evaluate fundamental movement skills in children with DCD and suggests that an increase of 10 points represents a significant change in the motor function of a child with DCD.

9.
Clin Linguist Phon ; : 1-18, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39007880

RESUMO

Single-word phonological tests are widely used for detecting children at risk for Speech Sound Disorders (SSDs). However, specific conceptual and operational criteria should be evaluated to ensure that these assessments are valid and reliable and can serve as diagnostic tools. The current study aimed to investigate the validity and reliability of the screener of a phonological Greek instrument, named the Phonological Assessment for Greek (PAel) comparing the phonological performance of typically developing (TD) children and children with SSDs, aged 4 to 6 years. The participants were 20 TD children and 40 children with SSDs. All participants completed the screener of PAel, the 70-word list of the standardised Test of Phonetic and Phonological Development (TPPD), and a language test, namely the Action Picture Test. Participants who scored below the 25th percentile on the language test were excluded. Phonological analysis revealed that PAel has high content validity. The participants who had received a diagnosis of SSDs presented restricted consonant and cluster inventories and significantly lower whole-word match levels in comparison to their TD peers. The overall Spearman's correlation coefficients between PAel and TPPD were 0.611 for TD children (p < 0.001) and 0.875 for children with SSDs (p < 0.001), indicating good criterion validity. The tool demonstrated strong test-retest reliability and inter-rater reliability with Spearman values exceeding 0.85, and Intra-class correlation coefficients over 0.90. Overall, the results suggest that PAel has satisfactory reliability and validity and can be used as an assessment tool to detect children at risk for SSDs.

10.
Artigo em Inglês | MEDLINE | ID: mdl-39008074

RESUMO

PURPOSE: To characterize the intra- and inter-operator reliability of a CT-based 3D preoperative planning software. MATERIALS AND METHODS: This study analyzed 30 CT scans of de-identified knees with osteoarthritis. For each scan, a case planner segmented the bones and pre-planned the TKA. Three orthopedic surgeons then reviewed each pre-planning three times at least one week apart, in a blinded manner. During the reviews, the surgeons modified the pre-plannings until they felt the plannings matched the objectives defined collegially at the beginning of the study. Reliability was assessed using the Intraclass Correlation Coefficient (ICC) and the Standard Error of Measurement (SEM). RESULTS: The intra- and inter-operator reliabilities for implant size selection were almost perfect (ICC between 0.97 and 0.99). Implants of same sizes were selected in 67.1-90.0% of cases. For implant placements, almost perfect intra- and inter-operator reliability was observed in all degrees-of-freedom (ICC between 0.81 and 1.00), except in flexion-extension for the femur (intra-operator ICC between: 0.76 and 0.99; inter-operator ICC of 0.61) and the tibia (intra-operator ICC between 0.12 and 1.00; inter-operator ICC of 0.03). All implant placements SEM were below 1.3 mm or 1.7°. CONCLUSIONS: This study showed high intra- and inter-operator reliability for implant size selection and, in most of the degrees-of-freedom, also for implant placements. Further research is needed to evaluate the benefit of developing more precise means of describing the objectives of the surgical planning as well as to evaluate the possibility and relevance of adding features in the planning software to assist the operators.

11.
Braz J Otorhinolaryngol ; 90(5): 101452, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38991400

RESUMO

OBJECTIVE: Perform the validation and psychometric evaluation of the Brazilian-Portuguese translation of the Functional Outcome of Sleep Questionnaire 10 (FOSQ10). MATERIALS AND METHODS: 182 patients (65 females 48.3±14.4 years and 117 males 46.9±12.4 years), were evaluated by sleep physicians suspected of having Obstructive Sleep Apnea, underwent polysomnography and completed the FOSQ-10 and the Epworth Sleepiness Scale. APA & NCME, 2014 was used to validate the data as the American Educational Research Association recommended. RESULTS: Quality indicators such as Bartlett's test of sphericity (χ2 = 1108.2; gL=45; p= 0.000010) and KMO (0.83), and adherence measures, attest to the quality of the model. The indicators TLI (0.97), CFI (0.98), and RMSEA (0.04) fall within the expected values. Using the Eigenvalue > 1 technique, two factors explain 53% and 13.3% of the variances. In the Parallel Analysis technique, a single factor explained 59.4653% of the random variance, and the Unidimensionality indicators UniCo = 0.921, ECV = 0.822, and MIREAL = 0.253, were supported. Construct Validity: reliability coefficients Cronbach's α = 0.87, McDonald's ordinal Omega index 0.9, and the Composite Reliability 0.891 were satisfactory. CONVERGENT VALIDITY: There was a significant Spearman correlation between FOSQ-10 and the Epworth Sleepiness Scale (r = 0.364 [-0.487; -0.226]). CRITERION VALIDITY: Was not possible to differentiate the groups based on the severity of AHI using FOSQ-10P. CONCLUSIONS: The Brazilian translation of FOSQ-10 is valid and reliable for identifying significant effects of excessive daytime sleepiness in patients with Obstructive Sleep Apnea.

12.
Afr J Emerg Med ; 14(3): 145-149, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38993947

RESUMO

Objective: To make a cross-cultural adaptation of the National Early Warning Score 2 (NEWS 2) from English to Angolan Portuguese. Methods: A methodological research of cross-cultural adaptation was conducted, involving sequential stages of forward translation, translation synthesis, back-translation, and the application of the Delphi Panel methodology for analyzing semantic, idiomatic, experiential, and conceptual equivalence between the translated and the original versions. This process culminated in the development of a pre-final version, which subsequently underwent testing in a cohort of nurses (n = 37). The Intraclass Correlation Coefficient was calculated to assess inter-rater reliability of ratings. Cronbach's alpha was used for evaluating the internal consistency and reliability within the items of the NEWS 2 score. Results: The cross-cultural adaptation process allowed us to prepare the final version of this tool. The data collected during the testing phase facilitated the examination of inter-rater reliability of ratings and the internal consistency and reliability within the items of the NEWS2 score. The Intraclass Correlation Coefficient observed at this step was 0.992. The Cronbach's alpha was 0.993. Conclusion: The cross-cultural adaptation of the NEWS 2 scoring system to Angolan Portuguese was successful, providing healthcare professionals in Angola with the means to effectively use the tool.

13.
Turk J Phys Med Rehabil ; 70(2): 188-196, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38948644

RESUMO

Objectives: The aim of this study was to investigate the validity and reliability of the Turkish version of the Functional Mobility Scale (FMS) in patients with cerebral palsy. Patients and methods: The validity and reliability study was conducted with 100 cerebral palsy patients (66 males, 34 females; mean age: 6.4±2.7 years; range, 2 to 18 years) between July 2015 and July 2018. The translation of the FMS was performed according to international standards. For test-retest reliability, 54 patients were reevaluated one week after the initial test with the Turkish version of the FMS, and Cohen's weighted kappa values were analyzed. The validity of the scale was assessed by correlating the FMS with the Gross Motor Function Classification System and the Gillette Functional Assessment Questionnaire Walking Scale. Twenty patients were evaluated by two researchers for interobserver reliability. Results: The kappa coefficients for test-retest reliability were 0.90 for FMS 5 m, 0.92 for FMS 50 m, and 0.91 for FMS 500 m. An evaluation of the validity revealed a significant correlation between FMS and the Gross Motor Function Classification System for all distances (r=-0.95, r=-0.96, and r=-0.92 for 5, 50, and 500 m, respectively; p <0.001), as well as the Gillette Functional Assessment Questionnaire Walking Scale (r=-0.95, r=-0.94, and r=-0.91 for 5, 50, and 500 meters, respectively; p <0.001). The kappa coefficients related to interobserver reliability were 0.73 for 5 m, 0.69 for FMS 50 m, and 0.81 for FMS 500 m. Conclusion: The Turkish version of the FMS can be considered a valid and reliable instrument for the assessment of cerebral palsy patients.

14.
APMIS ; 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38951722

RESUMO

Ki-67, a nuclear protein expressed in all stages of cellular proliferation, is a valuable tool to assess tumor proliferation and has been linked to more aggressive tumor behavior. However, interlaboratory staining heterogeneity and inter-observer variability challenge its reproducibility. Round Robin tests are a suitable tool to standardize and harmonize immunohistochemical and molecular analyses in histopathology. The study investigates the interrater and interlaboratory reproducibility of Ki-67-scoring using both manual and automated approaches. Unstained TMA slides comprising diverse tumor types (breast cancer, neuroendocrine tumors, lymphomas, and head and neck squamous cell carcinoma) were distributed to six pathology laboratories, each employing their routine staining protocols. Manual and automated scoring methods were applied, and interrater and interlaboratory agreement assessed using intraclass correlation coefficients (ICC). The results highlight good-to-excellent reliability overall, with automated scoring demonstrating higher consistency (ICC 0.955) than manual scoring (ICC 0.871). Results were more variable when looking at the individual entities. Reliability remained good for lymphomas (ICC 0.878) and breast cancer (ICC 0.784) and was poor in well-differentiated neuroendocrine tumors (ICC 0.354). This study clearly advocates standardized practices and training to ensure consistency in Ki-67-assessment, and it demonstrates that this can be achieved in a peer-to-peer approach in local quality-circles.

15.
Ann Geriatr Med Res ; 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38952332

RESUMO

Background: This study aimed to develop an instrument for assessing physical functioning among adults aged 50 years or older living in the community. Methods: Based on a review of various national health surveys and cohort studies, a 144-item bank was constructed for assessing physical functioning. Focus group interviews were conducted among adults aged 50 years or older to investigate their level of understanding of 60 selected items, followed by a pretest of the items on a nationally representative sample (n = 508). The final 25-item questionnaire was tested on an independent sample (n = 259) for validity and reliability based on classical test and item response theories. Predictive validity at the 6-month follow-up was tested in a separate sample (n = 263). Results: The newly developed Life Functioning (LF) scale assessed the dimensions of functional limitations, disabilities, and social activities. The scale satisfied a one-dimensionality assumption with good item fit and demonstrated criterion validity, construct validity, high internal consistency (Cronbach's alpha = 0.93), and test-retest reliability (intra-class correlation coefficient = 0.84; 95% CI, 0.76-0.89). The LF scale comprised 25 items with a total score ranging from 0 to 100. Higher scores indicated higher levels of functioning. The LF score was significantly associated with the physical functioning score at 6 months. Conclusion: The LF scale was developed to assess the physical functioning of people in their late midlife or older. Future studies should test the instrument on a national sample and evaluate its application in diverse population subgroups.

16.
Physiother Theory Pract ; : 1-8, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38946475

RESUMO

OBJECTIVE: This study seeks to assess the reliability and construct validity of the 1-minute sit-to-stand test as an efficient tool for evaluating the functional capacity of individuals with systemic sclerosis, considering its time and space effectiveness. METHODS: This cross-sectional study recruited forty-nine individuals with systemic sclerosis from a university hospital in Denmark. The 1-minute sit-to-stand test was conducted twice on the same day, with an interval of approximately 10 to 15 minutes between administrations, followed by a single administration of the 6-minute walk test. Reliability and validity were estimated using Bland-Altman statistics, intraclass correlation coefficient (ICC2,1), paired t-test, and Spearman's rank correlation coefficient (ρ). RESULTS: The 1-minute sit-to-stand test exhibited excellent test-retest reliability with an ICC2,1 (CI) of 0.97 (0.95-0.99). The minimal metrically detectable change between separate measures on a subject for the difference in the measures to be considered real at the 95% confidence level was 2.9 repetitions and 11%, respectively. A learning effect of one repetition was observed between repeated measures. High construct validity was observed between the 1-minute sit-to-stand and 6-minute walk test (ρ = 0.78, p < .001). CONCLUSIONS: This study demonstrates the 1-minute sit-to-stand test as highly reliable, with an 11% change indicating a true outcome change. It also demonstrates robust construct validity compared to the 6-minute walk test. The 1-minute sit-to-stand test appears feasible for assessing functional capacity in well-functioning individuals with systemic sclerosis, but prior familiarization with the task is recommended, as a small learning effect was observed with one repetition.

17.
Biomed Eng Lett ; 14(4): 859-866, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38946823

RESUMO

Practical application of surface-enhanced Raman spectroscopy (SERS) has suffered from several limitations by heterogeneous distribution of hot-spots, such as high signal fluctuation and the resulting low reliability in detection. Herein, we develop a strategy of more sensitive and reliable SERS platform through designing spatially homogeneous gold nanoparticles (GNPs) on a uniform gold nanoisland (GNI) pattern. The proposed SERS substrate is successfully fabricated by combining two non-lithographic techniques of electron beam evaporation and convective self-assembly. These bottom-up methods allow a simple, cost-effective, and large-area fabrication. Compared to the SERS substrates obtained from two separate nanofabrication methods, Raman spectra measured by the samples with both GNPs and GNIs present a significant increase in the signal intensity as well as a notable improvement in signal fluctuation. The simulated near-field analyses demonstrate the formation of highly amplified plasmon modes within and at the gaps of the GNP-GNI interfaces. Moreover, the suggested SERS sensor is evaluated to detect the glucose concentration, exhibiting that the detection sensitivity is improved by more than 10 times compared to the sample with only GNI patterns and a fairly good spatial reproducibility of 7% is accomplished. It is believed that our suggestion could provide a potential for highly sensitive, low-cost, and reliable SERS biosensing platforms that include many advantages for healthcare devices. Supplementary Information: The online version contains supplementary material available at 10.1007/s13534-024-00381-4.

18.
Qual Life Res ; 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38961010

RESUMO

PURPOSE: Systematic reviews evaluating and comparing the measurement properties of outcome measurement instruments (OMIs) play an important role in OMI selection. Earlier overviews of review quality (2007, 2014) evidenced substantial concerns with regards to alignment to scientific standards. This overview aimed to investigate whether the quality of recent systematic reviews of OMIs lives up to the current scientific standards. METHODS: One hundred systematic reviews of OMIs published from June 1, 2021 onwards were randomly selected through a systematic literature search performed on March 17, 2022 in MEDLINE and EMBASE. The quality of systematic reviews was appraised by two independent reviewers. An updated data extraction form was informed by the earlier studies, and results were compared to these earlier studies' findings. RESULTS: A quarter of the reviews had an unclear research question or aim, and in 22% of the reviews the search strategy did not match the aim. Half of the reviews had an incomprehensive search strategy, because relevant search terms were not included. In 63% of the reviews (compared to 41% in 2014 and 30% in 2007) a risk of bias assessment was conducted. In 73% of the reviews (some) measurement properties were evaluated (58% in 2014 and 55% in 2007). In 60% of the reviews the data were (partly) synthesized (42% in 2014 and 7% in 2007); evaluation of measurement properties and data syntheses was not conducted separately for subscales in the majority. Certainty assessments of the quality of the total body of evidence were conducted in only 33% of reviews (not assessed in 2014 and 2007). The majority (58%) did not make any recommendations on which OMI (not) to use. CONCLUSION: Despite clear improvements in risk of bias assessments, measurement property evaluation and data synthesis, specifying the research question, conducting the search strategy and performing a certainty assessment remain poor. To ensure that systematic reviews of OMIs meet current scientific standards, more consistent conduct and reporting of systematic reviews of OMIs is needed.

19.
Matern Child Nutr ; : e13677, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38961562

RESUMO

Poor measurement quality has set back the utility of anthropometry in defining childhood malnutrition, prompting calls for alternative measurement techniques. This study aimed to assess the reliability of anthropometric measurements using a digital height board in comparison to an analog height board in Namibian children under 5 years of age. A cross-sectional, descriptive study was conducted (n = 425) between the age of 6 and 59 months, using anthropometric measurements of weight, height and mid-upper arm circumference. Two trained enumerators each collected four height measurements of each child: two using an analog height board and two using a digi-board. The repeated height measurements between and within the enumerators were used to determine intra- and interobserver reliability. Reliability of the digi-board was assessed using the technical error of measurement (TEM), relative TEM (%TEM), intraclass correlation and a Bland-Altman analysis to assess the agreement between the two methods. In all these assessments, the analog height board was considered as the gold standard and used for comparison. The digi-board showed superiority to the analog height board in terms of reliability (analog TEM = 0.22, digi-board TEM = 0.16). Although the digi-board has potential to improve child anthropometry, further clinical and large survey studies are needed to validate the used of this tool in routine population-based surveys.

20.
Int J Occup Saf Ergon ; : 1-9, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38961651

RESUMO

Objectives. This study aimed to investigate the consistency between results of the American Conference for Governmental Occupational Hygienists (ACGIH) threshold limit value (TLV) for hand activity and proposed action levels of objective measurements in risk assessments of work-related musculoskeletal disorders. Methods. Wrist velocities and forearm muscular load were measured for 11 assemblers during one working day. Simultaneously, each assembler's hand activity level (HAL) during three sub-cycles was rated twice on two separate occasions by two experts, using a HAL scale. Arm/hand exertion was also rated by the assemblers themselves using a Borg scale. In total, 66 sub-cycles were assessed and assigned to three exposure categories: A) below ACGIH action limit (AL) (green); B) between AL and TLV (yellow); and C) above TLV (red). The median wrist velocity and the 90th percentile of forearm muscular load obtained from the objective measurements corresponding to the sub-cycles were calculated and assigned to two exposure categories: A) below or C) above the proposed action level. Results. The agreement between ACGIH TLV for hand activity and the proposed action level for wrist velocity was 87%. Conclusions. The proposed action level for wrist velocity is highly consistent with the TLV. Additional studies are needed to confirm the results.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...