Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 924
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39008078

RESUMO

BACKGROUND: The lateralization shoulder angle (LSA) and distalization shoulder angle (DSA) are used to reproducibly measure lateralization and distalization after reverse shoulder arthroplasty (RSA). However, LSA and DSA may not offer a precise measurement of humeral lateralization and distalization and this relationship has not been explored. The aim of this study was to evaluate the validity of these measurements and to propose new measurement methods to estimate implant lateralization and distalization. METHODS: 3D models were constructed from computed tomography (CT) scans of 30 patients using a software platform. For each patient 24 different RSA modifications were created, resulting in 720 different RSA configurations. For each configuration LSA and DSA angles as well as lateralization and distalization distances were measured. Moreover, for each configuration two new measurements were done: the lateralization index (LI) and distalization index (DI). Correlations of the lateralization and distalization parameters were evaluated between measurements. RESULTS: Weak correlations were founded between LSA and lateralization (r = 0.36, p < 0.01), whereas moderate correlations were observed between LI and lateralization (r = 0.72, p < 0.01). No significant correlations were found between DSA and distalization (r = 0.17, p = 0.113). In contrast, moderate correlations were identified between DI and distalization (r = 0.69, p < 0.01). CONCLUSION: LI and DI are more reliable methods to estimate implant lateralization and distalization compared to angular radiographic measurements. However, the prognostic significance in predicting clinical outcomes after RSA remains unknown.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38992415

RESUMO

BACKGROUND: Fractures of the acromion and spine can have a major impact on the outcome of reverse shoulder arthroplasty (RSA) with respect to pain, motion, and function. Reports on internal fixation for these fractures are isolated to small series or case reports with variable outcomes. The purpose of this study was to report on the outcome of open reduction and internal fixation (ORIF) of acromion or spine fractures encountered before or after RSA and describe our evolution of fixation techniques. METHODS: Between 2011 and 2023, 22 fractures or nonunions of the acromion or spine of the scapula underwent ORIF at a single institution and were followed for a minimum of 1 year. In 16 shoulders, fractures occurred after RSA, whereas 5 shoulders underwent ORIF prior to RSA. One shoulder had undergone prior failed ORIF elsewhere and revision ORIF was performed at our institution. There were 10 males and 12 females with a mean age of 67 (SD=15.1) years. Fixation strategies included single (n=11) and double plate fixation (n=11). Kruskal-Wallis one-way analyses of variance were used to analyze continuous variables and Chi-square tests employed for categorical variables. RESULTS: Of the 5 fractures treated with ORIF pre-RSA, 1 shoulder suffered an additional fracture medial to the hardware and 1 required additional bone grafting for incomplete union at the time of RSA. These 5 shoulders all underwent RSA uneventfully, but one fracture experienced late displacement of the scapular spine nonunion, leading to plate removal. Of the 16 post-RSA ORIF shoulders, radiographic union was confirmed in 14 and substantial residual inferior angulation identified in 3. New fractures occurred after ORIF in 5 shoulders. For patients who underwent ORIF after RSA, pain scores improved from a mean of 8 to 1.9 points, with more modest elevation gains (58.2° to 91.3° pre- and postoperatively, respectively). CONCLUSIONS: ORIF of acromion and scapular spine fractures or nonunions in the setting of RSA have the potential to lead to union. When these fractures and nonunions are encountered prior to RSA, ORIF allows for uneventful RSA implantation, but secondary displacement may occur. ORIF seems to lead to improvements in pain, but more modest improvements in motion and function. Our fixation strategy has evolved to (1) dual plating, (2) spanning the whole length of the spine with one of the plates, (3) use of hook features under the acromion or os trigonum if possible, and (4) liberal use of bone graft.

3.
JSES Int ; 8(4): 880-887, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39035638

RESUMO

Background: Stemless humeral components are being clinically investigated for reverse shoulder arthroplasty (RSA) procedures. There is, however, a paucity of basic science literature on the surgical parameters that influence the success of these procedures. Therefore, this cadaveric biomechanical study evaluated the neck shaft angle (NSA) of implantation on the survivability and performance of stemless RSA humeral components during cyclical loading. Methods: Twelve paired cadaveric humeri were implanted with stemless RSA humeral components at NSAs of 135° and 145°. Implant-bone motion at the periphery of the implant was measured with 3 optical machine vision USB3 cameras outfitted with c-mount premium lenses and quantified with ProAnalyst software. A custom 3-dimensional loading apparatus was used to cyclically apply 3 loading directions representative of physiological states at 5 progressively increasing loading magnitudes. Stemless 135° and 145° implants were compared based on the maximum implant-bone relative distraction detected, as well as the survivorship of the implants throughout the loading protocol. Results: Primary fixation and implant biomechanical survivorship were substantially better in the 145° NSA implants. The 135° NSA implants elicited significantly higher implant-bone distractions during cyclical loading (P = .001), and implant survivorship was considerably lower in the 135° NSA specimens when compared to the 145° NSA specimens (135° NSA: 0%, 145° NSA: 50%) (P < .001). Conclusion: NSA is a modifiable parameter that influences time-zero implant stability, as well as the early survivorship of the stemless RSA humeral components tested in this study. NSA resections of 145° appear to promote better stability than those utilizing 135° NSAs during early postoperative eccentric loads. Further studies are required to assess if other stemless reversed humeral implant designs have improved time-zero fixation at higher NSAs.

4.
JSES Int ; 8(4): 873-879, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39035641

RESUMO

Background: Peripheral nerve injury is a recognized complication after reverse shoulder arthroplasty (RSA) that has mainly been studied at the level of the brachial plexus and its proximal branches. However, the impact of RSA on distal peripheral nerves and the influence of elbow and wrist position is not known. This cadaveric study aimed to analyze the effect of RSA implantation and upper limb position on tension in the distal median and radial nerves. The hypothesis was that RSA increased distal nerve tension, which could be further affected by elbow and wrist position. Methods: 12 upper limbs in 9 full fresh-frozen cadavers were dissected. Nerve tension was measured in the median nerve at the level of the proximal arm, elbow, and distal forearm, and in the radial nerve at the level of the elbow, using a customized three-point tensiometer. Measurements were carried out before and after RSA implantation, using a semi-inlay implant (Medacta, Castel San Pietro, Switzerland). Two different configurations were tested, using the smallest and largest available implant sizes. Three upper-limb key positions were considered (plexus at risk, plexus relief, and neutral), from which the effect of elbow and wrist position was further tested. Results: RSA implantation significantly increased median and radial nerve tension throughout the upper limb. The distal nerve segments were particularly dependent on elbow and wrist position. The plexus at risk position induced the most tension in all nerve segments, especially with the large implant configuration. On the other hand, the plexus relief position induced the least amount of tension. Flexing the elbow was the most efficient way to decrease nerve tension in all tested nerve segments and key positions. Wrist flexion significantly decreased nerve tension in the median nerve, whereas wrist extension decreased tension in the radial nerve. Conclusion: RSA significantly increases tension in the median and radial nerves and makes them more susceptible to wrist and elbow positioning. The mechanism behind distal peripheral neuropathy after RSA may thus result from increased compression of tensioned nerves against anatomical fulcrums rather than nerve elongation alone. Elbow flexion was the most effective way to decrease nerve tension, while elbow extension should be avoided when implanting the humeral component. Further studies are needed to assess the ulnar nerve.

5.
JSES Int ; 8(4): 845-850, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39035637

RESUMO

Background: Higher bone or metal glenoid offset in reverse shoulder arthroplasty (RSA) reduces scapular notching, improves range of motion (ROM), and reduces postoperative instability. This retrospective multicenter study compared two implant designs to evaluate the short-term clinical and radiologic results of bone increased offset RSA (BIO-RSA) and metal increased offset RSA (MIO-RSA) in reverse shoulder. We hypothesized no difference between groups. Methods: This study analyzed n = 62 BIO-RSA and n = 90 MIO-RSA cases with a mean follow-up of 29.7 ± 6.0 months (BIO-RSA, range 24-49 months) and 24.0 ± 1.1 months (MIO-RSA, range 22-28 months). A 145°-onlay humeral stem was utilized in BIO-RSA cases, while a 135°-semi-inlay humeral stem was implanted in all MIO-RSA cases. Preoperative and postoperative radiologic imaging was reviewed to identify signs of scapular notching. Additionally, lateralization was evaluated according to Erickson et al. The constant score, subjective shoulder value, and ROM were evaluated during the baseline and follow-up consultations, and the findings of both groups were subsequently compared. Results: Scapular notching was observed in 7.0% (n = 8) of MIO-RSA cases and 8.1% (n = 5) of BIO-RSA cases (P = .801). MIO-group had a higher lateralization angle (P = .020) and the BIO-group had a higher distalization angle (P = .005). At baseline, mean constant score in the MIO-RSA group was higher than in the BIO-RSA group (P < .001), and it significantly increased to 67.8 ± 12.1P (MIO-RSA) and 69.5 ± 12.3P (BIO-RSA) to a similar level (P = .399). ROM improved in both groups with no significant difference between the two groups at follow-up. Conclusion: BIO-RSA and MIO-RSA in two distinct implant designs provide comparable short-term outcomes with a similar increase in shoulder function with notable variations in the lateralization and distalization angles between both implants. Scapular notching was rarely seen and unaffected by the method of glenoid lateralization. Follow-up investigations of both techniques are necessary to complement and track changes in the long-term outcome.

6.
Artigo em Inglês | MEDLINE | ID: mdl-39033959

RESUMO

BACKGROUND: Reverse shoulder arthroplasty (RSA) has proven to be an effective surgical procedure for irreparable rotator cuff tears, comminuted fractures of the proximal humerus and shoulder arthroplasty revision surgeries. We know from the literature that the functional results are good in the short term, but not whether these results remain stable in the long term or, on the contrary, show a deterioration in functionality. OBJECTIVE: This study aims to analyze the functionality, degree of satisfaction, complications, and prosthesis survival at different cut-off points in patients with complex proximal humerus fractures treated with RSA, with a minimum postoperative follow-up of 7 years. MATERIAL AND METHODS: Analytical, longitudinal and prospective observational study of a cohort of patients treated for a fracture of the proximal humerus with PIH. Functional outcome was assessed using the Constant scale and the Constant adjusted for age and gender of the patients. Quality of life was measured using the University of California at Los Angeles Shoulder Assessment scale (UCLA) and the Disability of the Arm, Shoulder and Hand score scale (QuickDASH). In addition, range of motion, pain and radiological variables of loosening, scapular notching and tuberosity consolidation were assessed. RESULTS: Thirty-three patients were included with a mean postoperative follow-up of 8.3 years (range 7-12 years). There was a progressive and significant decrease in Constant score at 5and7years follow-up compared to the baseline assessment 2 years after surgery, although the effect size was not significant. The age- and sex-adjusted Constant as well as the UCLA scale did not show statistically significant variations at follow-up. Both shoulder abduction and anterior shoulder flexion correlated well with the final QuickDASH score. Radiological variables did not influence any of the study outcome variables. CONCLUSION: The functionality and quality of life of patients with complex proximal humerus fractures treated with RSA decreased significantly compared to the 2-year evaluation, although this change was not clinically relevant. Survival of RSA was satisfactory in the medium to long term with a low complication rate.

7.
Artigo em Inglês | MEDLINE | ID: mdl-39033958

RESUMO

BACKGROUND: Regional anesthesia is a valuable component of multimodal pain control in total shoulder arthroplasty (TSA), and multiple interscalene block anesthetic options exist, including non-liposomal interscalene bupivacaine (NLIB) and liposomal interscalene bupivacaine (LIB). The purpose of the current of study was to compare pain control and opioid consumption within 48 hours postoperative in those undergoing TSA with either LIB or NLIB. METHODS: This was a retrospective cohort study at a single academic medical center including consecutive patients undergoing inpatient (>23-hour hospitalization) primary anatomic or reverse TSA from 2016 to 2020 who received either LIB or a NLIB for perioperative pain control. Perioperative patient outcomes were collected including pain levels and opioid usage, as well as 30- and 90-day ED visits or readmissions. The primary outcome was postoperative pain and opioid use. RESULTS: Overall, 489 patients were included in this study (316 LIB and 173 NLIB). Pain scores at 3, 6, 12, and 48 hours postoperatively were not statistically significantly different (p>0.05 for all). However, the LIB group had improved pain scores at 24- and 36-hours postoperative (p<0.05 all). There was no difference in the incidence of severe postoperative pain, defined as a 9 or 10 NRS-11 score, between the two anesthesia groups after adjusting for preoperative pain and baseline opioid use (OR: 1.25; 95% CI: 0.57-2.74; p=0.57). Overall, 99/316 (31.3%) of patients receiving LIB did not require any postoperative opioids compared with 38/173 (22.0%) receiving NLIB; however, this difference was not statistically significant after adjusting for prior opioid use and preoperative pain (p=0.33). No statistically significant differences in postoperative total morphine equivalents or mean daily morphine equivalents consumed between the groups were found during their hospital stays (p>0.05 for both). Finally, no significant differences in 30- and 90-day ED visits or readmission rates were found (all p>0.05). CONCLUSION: LIB and NLIB demonstrated differences in patient reported pain scores at 24- and 36-hours post operation, although these did not reach clinical significance. There were no statistically significant differences in opioid consumption during the hospital stay, including opioid use, total morphine equivalents and daily mean morphine equivalents consumed during the hospital stay. Additionally, no differences were observed in 30- and 90-day ED visits or readmission rates.

8.
Cureus ; 16(6): e61613, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38962641

RESUMO

Primary joint replacements are performed increasingly often worldwide, driven by an aging population, improvement in surgical techniques, and advancements in implant designs. While more attention has traditionally been focused on weight-bearing joints such as the hip and knee, shoulder replacement surgeries have gained increasing attention in recent years due to the population's demand for a better quality of life. Thus far, a comprehensive bibliometric analysis of shoulder arthroplasty-related publications using the Scopus database has not yet been conducted. This bibliometric analysis aims to fill this gap by reviewing the Scopus database from its inception until 2023 to examine the literature on shoulder arthroplasty. A total of 5300 publications meeting the selection criteria were included in this analysis. The turn of the century marked a significant turning point for the field of shoulder arthroplasty, with an increasing number of publications produced annually. This trend can be attributed to the improvement of implant designs, which have become more consistent and reliable over time. While the majority of articles were authored by researchers and clinicians from the United States of America (USA), publications by French authors had a higher scholarly impact in the field. There is a noticeable gap in research on shoulder arthroplasty in developing countries, possibly due to the prohibitively high cost of implants and the prioritization of other healthcare sectors. This bibliometric analysis, utilizing Scopus data, serves as a guiding light for researchers, clinicians, and policymakers, potentially fostering collaborative projects and guiding the development of future studies to further advance the field of shoulder arthroplasty, particularly in developing countries.

9.
J Clin Med ; 13(13)2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38999379

RESUMO

Reverse total shoulder arthroplasty (rTSA) is increasingly being used as a reliable option for various shoulder disorders with deteriorated rotator cuff and glenohumeral joints. The stemless humerus component for shoulder arthroplasties is evolving with theoretical advantages, such as preservation of the humeral bone stock and decreased risk of periprosthetic fractures, as well as clinical research demonstrating less intraoperative blood loss, reduced surgical time, a lower rate of intraoperative fractures, and improved center of rotation restoration. In particular, for anatomical total shoulder arthroplasty (aTSA), the utilization of stemless humeral implants is gaining consensus in younger patients. The current systematic review of 14 clinical studies (637 shoulders) demonstrated the clinical outcomes of stemless rTSA. Regarding shoulder function, the mean Constant-Murley Score (CS) improved from 28.3 preoperatively to 62.8 postoperatively. The pooled overall complication and revision rates were 14.3% and 6.3%, respectively. In addition, recent studies have shown satisfactory outcomes with stemless rTSA relative to stemmed rTSA. Therefore, shoulder surgeons may consider adopting stemless rTSA, especially in patients with sufficient bone quality. However, further long-term studies comparing survivorship between stemless and stemmed rTSA are required to determine the gold standard for selecting stemless rTSA.

10.
Artigo em Inglês | MEDLINE | ID: mdl-39025359

RESUMO

BACKGROUND: Acromial fractures after Reverse Total Shoulder Arthroplasty (RTSA) are a common complication. Nevertheless, only a few studies have identified risk factors for acromial fractures after RTSA. High delta angle (combination of inferiorization and medialization of the center of rotation) after RTSA was identified as a risk factor in recent studies. The aim of this study was the biomechanical exploration of different delta angles and implant configurations with regard to the acromial stress. METHODS: In a rigid body model of the upper extremity muscle, forces of the deltoid muscle were calculated before and after implanting RTSA in different arm and implant positions. The deltoid muscle was divided into an anterior, middle, and posterior part. Implant positions of the glenoid components were changed in the medialization, lateralization and inferiorization of the center of rotation (COR) as well as lateralization of the humeral component. Further, in a finite element model of the upper extremity, the stresses of the acromion in the same implant design configurations were measured. RESULTS: Differences in acromial stress between different delta angle model configurations were observed. Lateralization (5 mm, 10 mm) of the glenosphere reduced maximal acromial stress by 21% (1.5 MPa) and 31% (1.3 MPa), respectively. Inferiorization (5 mm, 10 mm) of the glenosphere increased maximal acromial stress by 5% (2.0 MPa) and 15% (2.2MPa), respectively. Changes in positioning the humeral component was found to have the highest impact in this model configuration. A 10 mm lateralized humeral component reduced acromial stress by 37% (1.2 MPa) while in the 6 mm medialized configuration, an increase in acromial stress by 83% (3.48 MPa) was observed. There was a high correlation between delta angle and acromial stress (R-squared = 0.967). CONCLUSION: Implant design configuration has an impact on the acromial stress. High delta angles correlate with an increase in acromial stress. Both lateralization of the COR and the humerus decreased the acromial stress in our study. The lateralization of the humerus has the highest impact in influencing acromial stress. Due to contrary results in the current literature, further studies with focus on the acromial stress influenced by different anatomical variants of the shoulder and the acromion are needed before a clinical recommendation can be made.

11.
Artigo em Inglês | MEDLINE | ID: mdl-38847836

RESUMO

BACKGROUND: Reverse shoulder arthroplasty (RSA) is a frequently used therapy for complex proximal humeral fractures and posttraumatic disorders. The present study's purpose was to assess the clinical and radiological outcome of primary and secondary RSA, and to analyze the impact of refixation of the greater tuberosity (GT). PATIENTS AND METHODS: 28 patients with primary fracture RSA and 18 patients with RSA due to posttraumatic disorders were examined with a mean clinical follow-up of 2.5 ± 1.73 years. Operative details and radiographs were retrospectively reviewed. Additional analyses were performed for healed and non-healed GT in primary RSA. RESULTS: Patients with fracture RSA had higher Constant-Murley score (CMS) than secondary RSA without reaching significance (p = 0.104). No significant difference was present for the quality of life measured by the Short Form 36 (SF 36) and the range of motion. In primary RSA, 78.6% GT healed anatomically. Compared to non-healed GT, patients with healed GT had a significantly higher CMS (p = 0.011), external rotation (p = 0.026) and forward flexion (p = 0.083), whereas DASH score was lower without a significant difference (p = 0.268). SF 36 showed no significant difference. Patients with healed GT had a more neutral glenoid version (p = 0.009). CONCLUSION: Superior range of motion and clinical outcome scores were present for anatomically healed GT. Therefore, refixation of the tuberosities is recommended. Secondary RSA can result in inferior results compared to primary RSA, so patients need to be adequately informed.

12.
BMC Musculoskelet Disord ; 25(1): 439, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38835042

RESUMO

BACKGROUND: The use of reverse total shoulder arthroplasty (RTSA) has increased at a greater rate than other shoulder procedures. In general, clinical and functional outcomes after RTSA have been favorable regardless of indication. However, little evidence exists regarding patient specific factors associated with clinical improvement after RTSA. Predicting postoperative outcomes after RTSA may support patients and physicians to establish more accurate patient expectations and contribute in treatment decisions. The aim of this study was to determine predictive factors for postoperative outcomes after RTSA for patients with degenerative shoulder disorders. METHODS: EMBASE, PubMed, Cochrane Library and PEDro were searched to identify cohort studies reporting on predictive factors for postoperative outcomes after RTSA. Authors independently screened publications on eligibility. Risk of bias for each publication was assessed using the QUIPS tool. A qualitative description of the results was given. The GRADE framework was used to establish the quality of evidence. RESULTS: A total of 1986 references were found of which 11 relevant articles were included in the analysis. Risk of bias was assessed as low (N = 7, 63.6%) or moderate (N = 4, 36.4%). According to the evidence synthesis there was moderate-quality evidence indicating that greater height predicts better postoperative shoulder function, and greater preoperative range of motion (ROM) predicts increased postoperative ROM following. CONCLUSION: Preoperative predictive factors that may predict postoperative outcomes are: patient height and preoperative range of motion. These factors should be considered in the preoperative decision making for a RTSA, and can potentially be used to aid in preoperative decision making. LEVEL OF EVIDENCE: Level I; Systematic review.


Assuntos
Artroplastia do Ombro , Amplitude de Movimento Articular , Articulação do Ombro , Humanos , Artroplastia do Ombro/efeitos adversos , Resultado do Tratamento , Articulação do Ombro/cirurgia , Articulação do Ombro/fisiopatologia
13.
Artigo em Inglês | MEDLINE | ID: mdl-38942222

RESUMO

BACKGROUND: Navigated augmented reality (AR) through a head-mounted display (HMD) has led to accurate glenoid component placement in reverse shoulder arthroplasty (RSA) in an in-vitro setting. The purpose of this study is to evaluate the deviation between planned, intra-, and postoperative inclination, retroversion, entry point and depth of the glenoid component placement during RSA, assisted by navigated AR through a HMD, in a surgical setting. METHODS: A prospective, multicenter study was conducted. All consecutive patients undergoing RSA in two institutions, between August 2021 and January 2023, were considered potentially eligible for inclusion in the study. Inclusion criteria were: age >18 years, surgery assisted by AR through a HMD, and postoperative computed tomography (CT) scans at six weeks. All participants agreed to participate in the study and an informed consent was provided in all cases. Preoperative CT scans were undertaken for all cases and used for three-dimensional (3D) planning. Intra-operatively, glenoid preparation and component placement were assisted by a navigated AR system through a HMD in all patients. Intraoperative parameters were recorded by the system. A postoperative CT scan was undertaken at 6 weeks, and 3D reconstruction was used for obtaining postoperative parameters. The deviation between planned, intra-, and postoperative inclination, retroversion, entry point, and depth of the glenoid component placement was calculated. Outliers were defined as >5° for inclination and retroversion and >5 mm for entry point. RESULTS: 17 patients (9 females, 12 right shoulders) with a mean age of 72.8±9.1 years old (range, 47.0 to 82.0) met inclusion criteria. The mean deviation between intra- and postoperative measurements was 1.5°±1.0° (range, 0.0° to 3.0°) for inclination, 2.8°±1.5° (range, 1.0° to 4.5°) for retroversion, 1.8±1.0 mm (range, 0.7mm to 3.0mm) for entry point, and 1.9±1.9 mm (range, 0.0mm to 4.5mm) for depth. The mean deviation between planned and postoperative values was 2.5°±3.2° (range, 0.0° to 11.0°) for inclination, 3.4°±4.6° (range, 0.0° to 18.0°) for retroversion, 2.0±2.5 mm (range, 0.0° to 9.7°) for entry point, and 1.3±1.6 mm (range, 1.3mm to 4.5mm) for depth. There were no outliers between intra- and postoperative values and there were three outliers between planned and postoperative values. The mean time (minutes:seconds) for the tracker unit placement and the scapula registration was 03:02 (range, 01:48 to 04:26) and 08:16 (range, 02:09 to 17:58), respectively. CONCLUSION: The use of a navigated AR system through a HMD in RSA led to low deviations between planned, intra-operative and postoperative parameters for glenoid component placement.

14.
J Clin Med ; 13(11)2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38893055

RESUMO

Background: The treatment of complex proximal humerus fractures in elderly patients is not yet fully elucidated. Of all treatment options, reverse shoulder arthroplasty (RSA) and non-operative treatment (NOT) appear to provide the best results. Evidence to guide the choice between the two is sparse. Therefore, this review provides an overview of the available evidence on RSA versus NOT. Methods: Studies comparing complex proximal humerus fractures in patients aged >65 years treated either with RSA or NOT were included for systematic review and direct comparison via pooled analysis of patient-rated outcome and range of motion. Indirect comparison of case series and non-comparative studies on either treatment was performed separately. Results: Three comparative studies including 77 patients treated with RSA and 81 treated non-operatively were analysed. The RSA group scored better for both the Constant-Murley score (mean difference 6 points) and DASH score (mean difference 8 points). No differences were detected in ASES, PENN score, pain scores, or range of motion between treatment groups. The most common complications for RSA were infection (3%), nerve injury (2%), and dislocation (2%). Reoperation was required in 5%. In the NOT group, common complications included malunion (42%), osteonecrosis (25%), and non-union (3%); no reoperation was required. Patient satisfaction was equal in both groups. Conclusions: The functional outcomes and range of motion after RSA seemed satisfactory and potentially superior to NOT in elderly patients. Patient satisfaction was comparable despite a high malunion and osteonecrosis rate in the non-operative treatment group, which did not require re-interventions.

15.
J ISAKOS ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38851325

RESUMO

BACKGROUND: Reverse shoulder arthroplasty (RSA) offers promising functional outcomes for young patients, yet challenges persist in restoring internal rotation (IR). This study aimed to assess the restoration of IR after RSA in patients younger than 60 years of age and analyze the factors affecting IR recovery. METHODS: A retrospective multicenter study was conducted, examining the functional outcome of patients who underwent RSA, with a minimum follow-up period of 2 years. Two subgroups of patients who underwent primary RSA were analyzed separately with respect to active internal rotation with the elbow at the side (AIR1): "difficult AIR1" and "easy AIR1." RESULTS: The study included 136 patients (overall series) with a mean age of 51.6 years. The overall series showed statistically significant improvement in active range of motion (RoM), pain, and Constant scores, especially with active IR (p â€‹< â€‹0.01). According to etiology, statistically significant improvement (p â€‹< â€‹0.05) in active IR was observed for fracture sequelae, primary osteoarthritis, and rheumatoid arthritis, whereas no statistically significant improvement in IR was observed for tumor, revision, and cuff-tear arthropathy (p â€‹> â€‹0.05). In subgroup analysis, patients with easy AIR1 displayed a statistically significant lower body mass index and better Constant score mobility, as well as improved motion in forward elevation and active IR (p â€‹< â€‹0.05). No statistically significant associations were found between improved IR and prosthetic design or subscapularis repair. Scapular notch, lysis of the graft, and teres minor atrophy were significantly associated with better active IR (p â€‹< â€‹0.05). CONCLUSION: RSA improves active RoM, pain, and functional outcomes in patients aged under 60. However, the degree of improvement in IR may vary depending on several factors and the underlying etiologies. These insights are crucial for patient selection and counseling, guiding RSA optimization efforts. LEVEL OF EVIDENCE: IV.

16.
Artigo em Inglês | MEDLINE | ID: mdl-38692404

RESUMO

BACKGROUND: Reverse shoulder arthroplasty (RSA) is a common procedure for treating a variety of shoulder pathologies. However, many patients struggle with postoperative internal rotation (IR) deficits, which often hinder their activities of daily living. The conjoint tendon provides an anatomic barrier that can impede the postoperative IR of the shoulder, and this study aims to evaluate the effect of a conjoint tendon lengthening on the glenohumeral range of motion (ROM) following RSA. METHODS: This study used ten fresh-frozen cadaver specimens of the upper extremity. An RSA was implanted using a standard deltopectoral approach, and the ROM was assessed postimplantation. Following this, the conjoint tendon was identified and lengthened using a tendon sheath z-plasty, and the ROM was rerecorded. Statistical significance for the ROM gains after conjoint tendon lengthening was determined with a significance level of P < .05. RESULTS: Following the lengthening of the conjoint tendon, there were statistically significant improvements in all ROMs (P < .05). Subjects demonstrated a notable gain in IR to the back by 10.3 cm (P < .01), and all ROMs increased by at least 10°, except for forward flexion, which increased by 6° (P < .001). CONCLUSIONS: This study suggests that lengthening the conjoint tendon improves postoperative ROM of the glenohumeral joint after RSA, offering a potential solution to considerable IR deficits that are commonly encountered post-RSA. Subsequent clinical and biomechanical studies should assess the stability of the shoulder joint following conjoint tendon lengthening.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...