Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.312
Filtrar
1.
J Pak Med Assoc ; 74(6): 1197-1198, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38949003

RESUMO

Skeletal scintigraphy has a pivotal role in detecting a number of bone pathologies, but it has its own limitations because of 2D image acquisition. Hybrid imaging acts as a savior in these cases where it is difficult to distinguish between benign and malignant lesions just on the basis of planar images. We present one such case of known breast carcinoma with abnormal increased radiotracer uptake in the skull which was difficult to characterize as benign lesion such as hyperostosis frontalis or metastatic osseous lesion. The importance of describing this case is to have a thorough understanding of hyperostosis patterns and to not confuse it with metastatic deposits in patients with known malignancies.


Assuntos
Neoplasias da Mama , Hiperostose Frontal Interna , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Feminino , Neoplasias da Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Diagnóstico Diferencial , Hiperostose Frontal Interna/diagnóstico por imagem , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Pessoa de Meia-Idade , Neoplasias Ósseas/secundário , Neoplasias Ósseas/diagnóstico por imagem
2.
Transl Androl Urol ; 13(6): 1053-1055, 2024 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-38983466
3.
Eur J Pharm Biopharm ; : 114398, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38972467

RESUMO

Human cathelicidin LL-37, a cationic host defense peptide (CHDP), has several important physiological roles, including antimicrobial activity, immune modulation, and wound healing, and is a being investigated as a therapeutic candidate for several indications. While the effects of endogenously produced LL-37 are well studied, the biodistribution of exogenously administered LL-37 are less known. Here we assess the biodistribution of a gallium-67 labeled variant of LL-37 using nuclear imaging techniques over a 48 h period in healthy mice. When administered as an intravenous bolus just over 20 µg, the LL-37-based radiotracer was rapidly cleared from the blood, largely by the liver, while an appreciable fraction of the dose temporarily distributed to the lungs. When administered subcutaneously at the same dose level, the radiotracer was absorbed systemically following a two-phase kinetic model and was predominately cleared renally. Uptake into sites rich in immune cells, such as the lymph nodes and the spleen, was observed for both routes of administration. Scans of free gallium-67 were also performed as controls. Important preclinical insights into the biodistribution of exogenously administered LL-37 were gained from this study, which can aid in the understanding of this and related cationic host-defense peptides.

4.
J Orthop Surg (Hong Kong) ; 32(2): 10225536241264977, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38897599

RESUMO

PURPOSE: Fracture-related infections (FRIs) encompass a broad range of infections associated with bone fractures; they remain a significant clinical challenge. Here, we aimed to investigate the viability of focusing on soft-tissue management in patients suspected of chronic FRI, who exhibit no significant bony uptake on bone single photon emission computed tomography (SPECT)/computed tomography (CT) scans. METHODS: Between January 2016 and January 2022, we managed 25 patients with chronic FRI or post-traumatic osteomyelitis using technetium 99m-methyl diphosphonate bone SPECT/CT to assess infection depth. Among them, 13 patients showing negligible bony uptake were included and categorized into two groups based on wound discharge reaching the bone/implant (Criteria 1, n = 6) or not (Criteria 2, n = 7). RESULTS: Patients in the Criteria 1 group were treated with antibiotics and soft tissue debridement without bony procedure. The average duration of antibiotic therapy was 6.7 weeks. Treatments were individualized, including implant changes, local flaps, skin grafts, and negative pressure wound therapy. No recurrence was reported in the mean follow-up of 21.3 months. Patients in the Criteria 2 group were treated with oral antibiotics (mean duration: 5.9 weeks) and daily wound dressings. No recurrence was reported in the mean follow-up of 26.0 months, and no surgical interventions were required. CONCLUSION: This study demonstrates the feasibility of focusing on soft-tissue management in patients with chronic FRI showing minimal bony uptake on bone SPECT/CT. Our treatment protocol avoided unnecessary surgical bone procedures, resulting in successful clinical outcomes with no recurrences.


Assuntos
Fraturas Ósseas , Osteomielite , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Masculino , Feminino , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Pessoa de Meia-Idade , Adulto , Osteomielite/diagnóstico por imagem , Osteomielite/etiologia , Osteomielite/terapia , Idoso , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/complicações , Antibacterianos/uso terapêutico , Antibacterianos/administração & dosagem , Doença Crônica , Desbridamento/métodos , Procedimentos Desnecessários , Estudos Retrospectivos
5.
EJNMMI Phys ; 11(1): 50, 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38898326

RESUMO

PURPOSE: This study aimed to assess the accuracy of patient-specific absorbed dose calculations for tumours and organs at risk in radiopharmaceutical therapy planning, utilizing hybrid planar-SPECT/CT imaging. METHODS: Three Monte Carlo (MC) simulated digital patient phantoms were created, with time-activity data for mIBG labelled to I-123 (LEHR and ME collimators) and I-131 (HE collimator). The study assessed the accuracy of the mean absorbed doses for I-131-mIBG therapy treatment planning. Multiple planar whole-body (WB) images were simulated (between 1 to 72 h post-injection (p.i)). The geometric-mean image of the anterior and posterior WB images was calculated, with scatter and attenuation corrections applied. Time-activity curves were created for regions of interest over the liver and two tumours (diameters: 3.0 cm and 5.0 cm) in the WB images. A corresponding SPECT study was simulated at 24 h p.i and reconstructed using the OS-EM algorithm, incorporating scatter, attenuation, collimator-detector response, septal scatter and penetration corrections. MC voxel-based absorbed dose rate calculations used two image sets, (i) the activity distribution represented by the SPECT images and (ii) the activity distribution from the SPECT images distributed uniformly within the volume of interest. Mean absorbed doses were calculated considering photon and charged particle emissions, and beta emissions only. True absorbed doses were calculated by MC voxel-based dosimetry of the known activity distributions for reference. RESULTS: Considering photon and charged particle emissions, mean absorbed dose accuracies across all three radionuclide-collimator combinations of 3.8 ± 5.5% and 0.1 ± 0.9% (liver), 5.2 ± 10.0% and 4.3 ± 1.7% (3.0 cm tumour) and 15.0 ± 5.8% and 2.6 ± 0.6% (5.0 cm tumour) were obtained for image set (i) and (ii) respectively. Considering charged particle emissions, accuracies of 2.7 ± 4.1% and 5.7 ± 0.7% (liver), 3.2 ± 10.2% and 9.1 ± 1.7% (3.0 cm tumour) and 13.6 ± 5.7% and 7.0 ± 0.6% (5.0 cm tumour) were obtained for image set (i) and (ii) respectively. CONCLUSION: The hybrid WB planar-SPECT/CT method proved accurate for I-131-mIBG dosimetry, suggesting its potential for personalized treatment planning.

6.
Cancers (Basel) ; 16(11)2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38893090

RESUMO

(1) Background: it is challenging to determine the accurate grades of cartilaginous bone tumors. Using bone single photon emission computed tomography (SPECT)/computed tomography (CT), maximum standardized uptake value (SUVmax) was found to be significantly associated with different grades of cartilaginous bone tumor. The inquiry focused on the effect of the tumor matrix on SUVmax. (2) Methods: a total of 65 patients from 2017 to 2022 with central cartilaginous bone tumors, including enchondromas and low-to-intermediate grade chondrosarcomas, who had undergone bone SPECT/CT were retrospectively enrolled. The SUVmax was recorded and any aggressive CT findings of cartilaginous bone tumor and Hounsfield units (HU) of the chondroid matrix as mean, minimum, maximum, and standard deviation (SD) were reviewed on CT scans. Pearson's correlation analysis was performed to determine the relationship between CT features and SUVmax. Subgroup analysis was also performed between the benign group (enchondroma) and the malignant group (grade 1 and 2 chondrosarcoma) for comparison of HU values and SUVmax. (3) Results: a significant negative correlation between SUVmax and HU measurements, including HUmax, HUmean, and HUSD, was found. The subgroup analysis showed significantly higher SUVmax in the malignant group, with more frequent CT aggressive features, and significantly lower HUSD in the malignant group than in the benign group. (4) Conclusions: it was observed that higher SUVmax and lower HUSD were associated with a higher probability of having a low-to-intermediate chondrosarcoma with aggressive features and a less calcified tumor matrix.

7.
J Nucl Med Technol ; 52(2): 181-182, 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38839115

RESUMO

A 63-y-old woman with a history of breast cancer presented with concerns of osseous metastasis. Initial whole-body planar bone scintigraphy revealed a focus of concern overlying the sternum. SPECT/CT images revealed the anomaly-localized activity in the needleless hub attached to the chemotherapy port. If not for the precision of SPECT/CT, such a rare artifact could have led to a false-positive diagnosis, particularly impactful in breast cancer patients. This case emphasizes the critical role of SPECT/CT in accurate diagnoses.


Assuntos
Neoplasias da Mama , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Feminino , Pessoa de Meia-Idade , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Artefatos
8.
Cureus ; 16(5): e59834, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38846237

RESUMO

Ectopic thyroid tissue is very rare, but the coexistence of ectopic and eutopic thyroid glands is even more rare. The recognition of this diagnosis is important in patients who are being treated for thyrotoxicosis, but it is also crucial to exclude other associated serious disease conditions. In this article, we report three different cases that showed ectopic thyroid tissue with the coexisting presence of an eutopic thyroid gland. All three cases showed different outcomes. The recognition of this condition is of great importance because it alerts the referring physicians to this rare, yet possible occurrence and the potential pathological conditions associated with it. The first case showed how imaging could help outline even small ectopic thyroid tissue outside of the neck region even in cases where histopathological confirmation is difficult. The second case was very rare as thyroid carcinoma originated in ectopic thyroid tissue. In the last case, the initial imaging was misleading as it mimicked greatly ectopic thyroid tissue, and only detailed history and careful inspection of the images could lead to the correct interpretation of the findings.

9.
Artigo em Inglês | MEDLINE | ID: mdl-38914769

RESUMO

PURPOSE: An international survey was conducted by the Cardiovascular Interventional Radiological Society of Europe (CIRSE) to evaluate radioembolization practice and capture opinions on real-world clinical and technical aspects of this therapy. MATERIALS AND METHODS: A survey with 32 multiple choice questions was sent as an email to CIRSE members between November and December 2022. CIRSE group member and sister societies promoted the survey to their local members. The dataset was cleaned of duplicates and entries with missing data, and the resulting anonymized dataset was analysed. Data were presented using descriptive statistics. RESULTS: The survey was completed by 133 sites, from 30 countries, spanning 6 continents. Most responses were from European centres (87/133, 65%), followed by centres from the Americas (22/133, 17%). Responding sites had been performing radioembolization for 10 years on average and had completed a total of 20,140 procedures over the last 5 years. Hepatocellular carcinoma treatments constituted 56% of this total, colorectal liver metastasis 17% and cholangiocarcinoma 14%. New sites had opened every year for the past 20 years, indicating the high demand for this therapy. Results showed a trend towards individualized treatment, with 79% of responders reporting use of personalized dosimetry for treatment planning and 97% reporting routine assessment of microsphere distribution post-treatment. Interventional radiologists played an important role in referrals, being present in the referring multi-disciplinary team in 91% of responding centres. CONCLUSION: This survey provides insight into the current state of radioembolization practice globally. The results reveal the increasing significance placed on dosimetry, evolving interventional techniques and increased technology integration.

10.
World J Nucl Med ; 23(2): 88-94, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38933062

RESUMO

Objective Technetium-99m ethylene dicysteine (Tc-99m EC) is a well-established, tubular tracer for diuretic renography. Few occasional cases have been reported in literature regarding visualization of liver, gallbladder (GB), or bowel due to increased hepatobiliary route of excretion of Tc-99m EC on diuretic renography. This study aimed to retrospectively review the incidence of visualization of liver, GB, or bowel and its clinical significance in Tc-99m EC diuretic renography. Materials and Methods Data of all patients who underwent diuretic renography in the department from January 24, 2022 to March 31, 2023 was included in the study. The data was analyzed to assess the incidence of visualization of GB or bowel loops, correlation of the hepatobiliary localization with factors like age of the patient, concentration of 99m TcO4 solution, quality control parameters, presence of renal stone disease, serum creatinine, relative renal function, and effective renal plasma flow. Effect of hepatobiliary localization on scan interpretation and reporting was assessed. Results The retrospective analysis of 437 diuretic renograms revealed the hepatobiliary localization of tracer in 34 patients. Out of these 34 patients, 14 patients had only faint visualization of tracer at 4 hours delayed image. Twenty scans had visualization of both GB and bowel. Out of these 20 scans, GB and bowel were visualized during dynamic imaging in one scan, after initial 20 minutes in two scans and in 2 to 4 hours delayed images in rest of the 17 scans. Two out of 20 patients had increased serum creatinine, 16 patients had either single kidney or relative renal function less than 26%, and 12 patients had renal stone disease. Out of the four patients in whom relative renal function was more than 25%, one patient had raised serum creatinine and three patients had renal stone disease. Interpretation of images was affected only in three patients, in which reporting of the scans required single-photon emission computed tomography imaging and correlation with other imaging modalities. Conclusion Hepatobiliary excretion of Tc-99m EC usually does not usually affect the scan interpretation and quantitative renogram analysis, but reader should be cognizant of the potential pitfalls during scan interpretation. In this study, we reviewed the possible causes of this hepatobiliary clearance and importance of additional views and correlation with other imaging modalities to clarify the suspicion arises for accurate reporting.

11.
World J Nucl Med ; 23(2): 130-134, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38933072

RESUMO

Differentiated thyroid carcinoma (DTC) usually is slow growing and carries a good prognosis. It most commonly tends to spread locally to regional lymph nodes in 20 to 60% of patients. The presence of distant metastasis impacts overall survival and prognosis. The lungs, bones, and the brain are typically involved in distant sites with less common metastatic sites that include the liver, kidney, skeletal muscle, adrenal glands, bladder, and skin. These unusual sites are rare and pose a diagnostic challenge and impact clinical decision-making to a great extent. The radioiodine 131 I whole-body scintigraphy with single-photon emission computed tomography/computed tomography can provide a thorough investigation of unusual sites of uptake leading to diagnosis of these metastases. We present a case series of DTC showing unusual sites of metastasis and/or radioiodine uptake in urinary bladder, in the third metacarpal bone of left hand and lastly in the forearm at postoperative hypertrophic scar area.

12.
EJNMMI Phys ; 11(1): 52, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38937408

RESUMO

BACKGROUND: Although the importance of quantitative SPECT has increased tremendously due to newly developed therapeutic radiopharmaceuticals, there are still no accreditation programs to harmonize SPECT imaging. Work is currently underway to develop an accreditation for quantitative 177Lu SPECT/CT. The aim of this study is to verify whether the positioning of the spheres within the phantom has an influence on the recovery and thus needs to be considered in SPECT harmonization. In addition, the effects of these recovery coefficients on a potential partial volume correction as well as absorbed-dose estimates are investigated. METHODS: Using a low-dose CT of a SPECT/CT acquisition, a computerized version of the NEMA body phantom was created using a semi-automatic threshold-based method. Based on the mass-density map, the detector orbit, and the sphere centers, realistic SPECT acquisitions of all possible 720 sphere configurations of both the PET and the SPECT versions of the NEMA Body Phantom were generated using Monte Carlo simulations. SPECT reconstructions with different numbers of updates were performed without (CASToR) and with resolution modeling (STIR). Recovery coefficients were calculated for all permutations, reconstruction methods, and phantoms, and their dependence on the sphere positioning was investigated. Finally, the simulation-based findings were validated using SPECT/CT acquisitions of six different sphere configurations. RESULTS: Our analysis shows that sphere positioning has a significant impact on the recovery for both of the reconstruction methods and the phantom type. Although resolution modeling resulted in significantly higher recovery, the relative variation in recovery within the 720 permutations was even larger. When examining the extreme values of the recovery, reconstructions without resolution modeling were influenced primarily by the sphere position, while with resolution modeling the volume of the two adjacent spheres had a larger influence. The SPECT measurements confirmed these observations, and the recovery curves showed good overall agreement with the simulated data. CONCLUSION: Our study shows that sphere positioning has a significant impact on the recovery obtained in NEMA sphere phantom measurements and should therefore be considered in a future SPECT accreditation. Furthermore, the single-measurement method normally performed for PVC should be reconsidered to account for the position dependency.

13.
Life (Basel) ; 14(6)2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38929734

RESUMO

Rheumatoid arthritis (RA) is a systemic autoimmune disorder caused by inflammation of cartilaginous diarthrodial joints that destroys joints and cartilage, resulting in synovitis and pannus formation. Timely detection and effective management of RA are pivotal for mitigating inflammatory arthritis consequences, potentially influencing disease progression. Nuclear medicine using radiolabeled targeted vectors presents a promising avenue for RA diagnosis and response to treatment assessment. Radiopharmaceutical such as technetium-99m (99mTc), combined with single photon emission computed tomography (SPECT) combined with CT (SPECT/CT), introduces a more refined diagnostic approach, enhancing accuracy through precise anatomical localization, representing a notable advancement in hybrid molecular imaging for RA evaluation. This comprehensive review discusses existing research, encompassing in vitro, in vivo, and clinical studies to explore the application of 99mTc radiolabeled targeting vectors with SPECT imaging for RA diagnosis. The purpose of this review is to highlight the potential of this strategy to enhance patient outcomes by improving the early detection and management of RA.

14.
J Nucl Med Technol ; 52(2): 86-90, 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38839121

RESUMO

Our rationale was to review the imaging options for patients with primary hyperparathyroidism and to advocate for judicious use of 4-dimensional (4D) SPECT/CT to visualize diseased parathyroid glands in patients with complex medical profiles or in whom other imaging modalities fail. We review the advantages and disadvantages of traditional imaging modalities used in preoperative assessment of patients with primary hyperparathyroidism: ultrasound, SPECT, and 4D CT. We describe a scheme for optimizing and individualizing preoperative imaging of patients with hyperfunctioning parathyroid glands using traditional modalities in tandem with 4D SPECT/CT. Using the input from radiologists, endocrinologists, and surgeons, we apply patient criteria such as large body habitus, concomitant multiglandular disease, multinodular thyroid disease, confusing previous imaging, and unsuccessful previous surgery to create an imaging paradigm that uses 4D SPECT/CT yet is cost-effective, accurate, and limits extraneous radiation exposure. 4D SPECT/CT capitalizes on the strengths of SPECT and 4D CT and addresses limitations that exist when these modalities are used in isolation. In select patients with complicated clinical parameters, preoperative imaging with 4D SPECT/CT can improve accuracy yet remain cost-effective.


Assuntos
Tomografia Computadorizada Quadridimensional , Hiperparatireoidismo Primário , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Hiperparatireoidismo Primário/diagnóstico por imagem , Hiperparatireoidismo Primário/cirurgia , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada Quadridimensional/métodos
15.
Phys Eng Sci Med ; 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38884669

RESUMO

Performance testing of gamma cameras and single photon computed tomography/computed tomography (SPECT/CT) systems is not subject to regulatory requirements across states and territories in Australia. Internationally recognised testing standards from organisations such as the National Electrical Manufacturers Association (NEMA) describe methodologies for recommended tests. However, variations exist in suggested quality control (QC) schedules from professional bodies such as the Australia and New Zealand Society of Nuclear Medicine (ANZSNM). In this study, a survey was conducted to benchmark current QC programs across a selected sample of eight standalone and networked Australian public hospitals. Vendor-specific flood-field uniformity (intrinsic or extrinsic/system) verification without photomultiplier (PMT) tuning and CT QC were performed at all sites. Weekly and monthly PMT tuning followed by intrinsic flood-field verifications were performed at most sites. At least half of the sites performed monthly centre of rotation (COR) offset verifications. SPECT/CT alignment calibrations and verifications were undertaken by service engineers at all sites, and periodic verifications were performed by local staff at varying frequencies. Variations were observed for other periodic QC tests such as spatial resolution and planar sensitivity. Similarly, variations were observed for tests specific to whole-body systems and SPECT systems. Most sites checked daily and periodic QC results against pass/fail criteria set by vendors. Additional analyses of the QC results, including trend analysis and periodic reviews, were not common practice. The lack of regulatory requirements is likely to have led to variations in QC tests that are generally either harder to perform or are more labour intensive.

16.
Radiologia (Engl Ed) ; 66(3): 236-247, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38908885

RESUMO

Preoperative localization of parathyroid pathology, generally a parathyroid adenoma, can be difficult in some cases due to the anatomical variants that these glands present. The objective of this review is to analyse the different imaging techniques used for preoperative localization of parathyroid pathology (scintigraphy, ultrasound, CT, MRI and PET). There is great variability between the different tests for the preoperative localization of parathyroid pathology. The importance of knowing the different diagnostic options lies in the need to choose the most suitable test at each moment and for each patient for an adequate management of primary hyperparathyroidism (PHP) with surgical criteria.


Assuntos
Neoplasias das Paratireoides , Humanos , Neoplasias das Paratireoides/diagnóstico por imagem , Ultrassonografia/métodos , Diagnóstico por Imagem/métodos , Hiperparatireoidismo Primário/diagnóstico por imagem , Glândulas Paratireoides/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Doenças das Paratireoides/diagnóstico por imagem
17.
Quant Imaging Med Surg ; 14(5): 3665-3675, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38720856

RESUMO

Background: Single-photon emission computed tomography-computed tomography (SPECT/CT) quantification has emerged as a valuable tool for assessing disease prognosis by accurately identifying and characterizing abnormal lesions with accumulated radionuclides. Papillary thyroid carcinoma (PTC) is the most prevalent type of thyroid cancer, and radioactive iodine (RAI) therapy is a standard treatment following total thyroidectomy. This study aimed to explore the potential utility the quantitative parameters of the thyroid bed under iodine-131 (I-131) SPECT/CT in the efficacy of RAI adjuvant therapy for patients with PTC. Methods: The retrospective cohort study enrolled 107 patients with PTC who underwent RAI adjuvant therapy from June 2020 to January 2023. Three days after the RAI adjuvant therapy, all patients underwent I-131 whole-body scans and SPECT/CT imaging. The quantitative parameters, including maximum standardized uptake value (SUVmax), mean standardized uptake value (SUVmean), and percent injected dose (%ID), were measured using image analysis software based on I-131 SPECT/CT thyroid bed uptake. Successful therapy was defined as inhibitory thyroglobulin (Tg) <0.2 ng/mL with negative thyroglobulin antibody (TgAb) and negative imaging examination 6 months after RAI adjuvant therapy. The relationship between the quantitative parameters and the treatment efficacy, in addition to the potential influencing factors, were analyzed. Results: The quantitative parameters from the successful group [SUVmax: median 6.15 g/mL, interquartile range (IQR) 2.34-13.80 g/mL; SUVmean: median 2.02 g/mL, IQR 0.89-4.93 g/mL; %ID: median 2.00%, IQR 1.00-4.00%] were significantly lower than those from the unsuccessful group (SUVmax: median 19.03 g/mL, IQR 5.31-45.10 g/mL, SUVmean 4.64 g/mL, IQR 2.07-19.05 g/mL; %ID: median 8.00%, IQR 3.00-18.00%) (SUVmax: Z=-3.755; SUVmean; Z=-3.671; %ID: Z=-4.070; all P values <0.001). SUVmax, SUVmean and %ID were positively correlated with the stimulated thyroglobulin (sTg) and inhibitory Tg at 6 months after RAI adjuvant therapy, respectively (all P values <0.001). SUVmax [odds ratio (OR) =1.045], SUVmean (OR =1.130), and %ID (OR =1.092) were predictive factors for the failure of RAI adjuvant therapy (all P values <0.001). Conclusions: Our study suggested that quantitative parameters (SUVmax, SUVmean, and %ID) derived from I-131 SPECT/CT imaging of the thyroid bed can serve as useful tools for predicting therapy outcomes following RAI adjuvant therapy.

18.
EJNMMI Phys ; 11(1): 41, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38722528

RESUMO

BACKGROUND: A new, alternative option for patients with recurrent glioblastoma is targeted alpha therapy (TAT), in the form of a local administration of substance P (neurokinin type 1 receptor ligand, NK-1) labelled with 225Ac. The purpose of the study was to confirm the feasibility of quantitative SPECT imaging of 225Ac, in a model reproducing specific conditions of TAT. In particular, to present the SPECT calibration methodology used, as well as the results of validation measurements and their accuracy. Additionally, to discuss the specific problems related to high noise in the presented case. MATERIALS AND METHODS: All SPECT/CT scans were conducted using the Symbia T6 equipped with HE collimators, and acquired with multiple energy windows (three main windows: 440 keV, 218 keV, and 78 keV, with three lower scatter energy windows). A Jaszczak phantom with fillable cylindrical sources of various sizes was used to investigate quantitative SPECT/CT imaging characteristics. The planar sensitivity of the camera, an imaging calibration factor, and recovery coefficients were determined. Additionally, the 3D printed model of the glioblastoma tumour was developed and imaged to evaluate the accuracy of the proposed protocol. RESULTS: Using the imaging calibration factor and recovery coefficients obtained with the Jaszczak phantom, we were able to quantify the activity in a 3D-printed model of a glioblastoma tumour with uncertainty of no more than 10% and satisfying accuracy. CONCLUSIONS: It is feasible to perform quantitative 225Ac SPECT/CT imaging. However, there are still many more challenges that should be considered for further research on this topic (among others: accurate determination of ICF in the case of high background noise, better method of background estimation for recovery coefficient calculations, other methods for scatter correction than the dual-energy window scatter-compensation method used in this study).

19.
J Nucl Med ; 65(7): 1064-1069, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38724282

RESUMO

Understanding the relationship between lesion-absorbed dose and tumor response in 177Lu-PSMA-617 radiopharmaceutical therapies (RPTs) remains complex. We aimed to investigate whether baseline lesion-absorbed dose can predict lesion-based responses and to explore the connection between lesion-absorbed dose and prostate-specific antigen (PSA) response. Methods: In this retrospective study, we evaluated 50 patients with 335 index lesions undergoing 177Lu-PSMA-617 RPT, who had dosimetry analysis performed on SPECT/CT at 24 h after cycles 1 and 2. First, we identified the index lesions for each patient and measured the lesion-based absorbed doses. Lesion-based response was calculated after cycle 2. Additionally, PSA50 response (a decline of 50% from baseline PSA) after cycle 2 was also calculated. The respective responses for mean and maximum absorbed doses and prostate-specific membrane antigen (PSMA) volumetric intensity product (VIP-PSMA) at cycles 1 and 2 were termed SPECTmean, SPECTmaximum, and SPECTVIP-PSMA, respectively. Results: Of the 50 patients reviewed, 46% achieved a PSA50 response after cycle 2. Of the 335 index lesions, 58% were osseous, 32% were lymph nodes, and 10% were soft-tissue metastatic lesions. The SPECT lesion-based responses were higher in PSA responders than in nonresponders (SPECTmean response of 46.8% ± 26.1% vs. 26.2% ± 24.5%, P = 0.007; SPECTmaximum response of 45% ± 25.1% vs. 19% ± 27.0%, P = 0.001; SPECTVIP-PSMA response of 49.2% ± 30.3% vs. 14% ± 34.7%, P = 0.0005). An association was observed between PSA response and SPECTVIP-PSMA response (R 2 = 0.40 and P < 0.0001). A limited relationship was found between baseline absorbed dose measured with a 24-h single time point and SPECT lesion-based response (R 2 = 0.05, P = 0.001, and R 2 = 0.03, P = 0.007, for mean and maximum absorbed doses, respectively). Conclusion: In this retrospective study, quantitative lesion-based response correlated with patient-level PSA response. We observed a limited relationship between baseline absorbed dose and lesion-based responses. Most of the variance in response remains unexplained solely by baseline absorbed dose. Establishment of a dose-response relationship in RPT with a single time point at 24 h presented some limitations.


Assuntos
Neoplasias da Próstata , Compostos Radiofarmacêuticos , Humanos , Masculino , Compostos Radiofarmacêuticos/uso terapêutico , Idoso , Estudos Retrospectivos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Pessoa de Meia-Idade , Antígeno Prostático Específico/sangue , Resultado do Tratamento , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Compostos Heterocíclicos com 1 Anel/uso terapêutico , Dipeptídeos/uso terapêutico , Idoso de 80 Anos ou mais , Fatores de Tempo , Lutécio , Glutamato Carboxipeptidase II/metabolismo
20.
Cancers (Basel) ; 16(10)2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38792005

RESUMO

This review highlights recent advances in renal cell carcinoma (RCC) imaging. It begins with dual-energy computed tomography (DECT), which has demonstrated a high diagnostic accuracy in the evaluation of renal masses. Several studies have suggested the potential benefits of iodine quantification, particularly for distinguishing low-attenuation, true enhancing solid masses from hyperdense cysts. By determining whether or not a renal mass is present, DECT could avoid the need for additional imaging studies, thereby reducing healthcare costs. DECT can also provide virtual unenhanced images, helping to reduce radiation exposure. The review then provides an update focusing on the advantages of multiparametric magnetic resonance (MR) imaging performance in the histological subtyping of RCC and in the differentiation of benign from malignant renal masses. A proposed standardized stepwise reading of images helps to identify clear cell RCC and papillary RCC with a high accuracy. Contrast-enhanced ultrasound may represent a promising diagnostic tool for the characterization of solid and cystic renal masses. Several combined pharmaceutical imaging strategies using both sestamibi and PSMA offer new opportunities in the diagnosis and staging of RCC, but their role in risk stratification needs to be evaluated. Although radiomics and tumor texture analysis are hampered by poor reproducibility and need standardization, they show promise in identifying new biomarkers for predicting tumor histology, clinical outcomes, overall survival, and the response to therapy. They have a wide range of potential applications but are still in the research phase. Artificial intelligence (AI) has shown encouraging results in tumor classification, grade, and prognosis. It is expected to play an important role in assessing the treatment response and advancing personalized medicine. The review then focuses on recently updated algorithms and guidelines. The Bosniak classification version 2019 incorporates MRI, precisely defines previously vague imaging terms, and allows a greater proportion of masses to be placed in lower-risk classes. Recent studies have reported an improved specificity of the higher-risk categories and better inter-reader agreement. The clear cell likelihood score, which adds standardization to the characterization of solid renal masses on MRI, has been validated in recent studies with high interobserver agreement. Finally, the review discusses the key imaging implications of the 2017 AUA guidelines for renal masses and localized renal cancer.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...