J Xray Sci Technol ; 31(4): 745-756, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37092211

RESUMO

OBJECTIVE: The aim of this study is to investigate the radiation dose and image quality of head CT using SPS and OBTCM techniques. METHODS: Three anthropomorphic head phantoms (1-yr-old, 5-yr-old, and adult) were used. Images were acquired using four modes (Default protocol, OBTCM, SPS, and SPS+OBTCM). Absorbed dose to the lens, anterior brain (brain_A), and posterior brain (brain_P) was measured and compared. Image noise and CNR were assessed in the selected regions of interest (ROIs). RESULTS: Compared with that in the Default protocol, the absorbed dose to the lens reduced by up to 28.33%,71.38%, and 71.12% in OBTCM, SPS, and SPS+OBTCM, respectively. The noise level in OBTCM slightly (≤1.45HU) increased than that in Default protocol, and the SPS or SPS+OBTCM mode resulted in a quantitatively small increase (≤2.58HU) in three phantoms. There was no significant difference in CNR of different phantoms under varies scanning modes (p > 0.05). CONCLUSIONS: During head CT examinations, the SPS mode can reduce the radiation dose while maintaining image quality. SPS+OBTCM couldn't further effectively reduce the absorbed dose to the lens for 1-yr and 5-yr-old phantoms. Thus, SPS mode in pediatric and SPS+OBTCM mode in adult are better than other modes, and should be used in clinical practice.


Assuntos
Redução da Medicação , Proteção Radiológica , Adulto , Humanos , Criança , Doses de Radiação , Proteção Radiológica/métodos , Cabeça/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas
2.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-932590

RESUMO

Objective:To compare the dose and image quality of selected photon shield (SPS) technique, organ-based tube current modulation (OBTCM) technique and the combination of these two techniques for reducing the organ dose in head CT examination for infants.Methods:Two anthropomorphic head phantoms (CIRS 1-yr-old and 5-yr-old) were scanned by using Reference mode, Reference + OBTCM mode, SPS mode and SPS + OBTCM mode, respectively. Radiation doses to the lens of the eye, the anterior of the brain, the posterior of the brain, noise level and CNR of orbit and brain in different phantoms were measured and compared by using different scanning modes.Results:Compared with Reference mode, the doses to the lens of the eye in 1-yr-old and 5-yr-old phantom decreased by (21.89 ± 0.01)% and (28.33 ± 0.34)%, respectively. In SPS mode, the reduction in doses to the lens of the eye in 1-yr-old and 5-yr-old phantom were (71.38 ± 1.30)% and (53.72 ± 2.42)%, respectively. In SPS + OBTCM mode, the reduction was (71.12 ± 2.54)% and (55.73 ± 1.90)%, respectively. There was significant difference in the noise level of orbit and brain in different phantoms under various scanning modes ( F=5.67-85.47, P< 0.05). The noise level in OBTCM mode compared with reference mode increased slightly (<1.45 HU) in various phantoms. SPS and SPS + OBTCM mode resulted in a small noise increase (<2.58 HU). There was no significant difference in CNR of different phantoms under various scanning modes ( P>0.05). Conclusions:SPS and SPS + OBTCM mode can significantly reduce the radiation dose of lens and the whole image plane in the head CT scan for infants, with maintaining the image quality.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA