Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 328
Filtrar
1.
Artif Organs ; 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-38994666

RESUMO

The human hand, with its intricate sensory capabilities, plays a pivotal role in our daily interactions with the world. This remarkable organ possesses a wide range of natural sensors that enrich our experiences, enabling us to perceive touch, position, and temperature. These natural sensors work in concert to provide us with a rich sensory experience, enabling us to distinguish between various textures, gauge the force of our grip, determine the position of our fingers without needing to see them, perceive the temperature of objects we come into contact with or detect if a cloth is wet or dry. This complex sensory system is fundamental to our ability to manipulate objects, explore our surroundings, and interact with the world and people around us. In this article, we summarize the research performed in our laboratories over the years and our findings to restore both touch, position, and temperature modalities. The combination of intraneural stimulation, sensory substitution, and wearable technology opens new possibilities for enhancing sensory feedback in prosthetic hands, promising improved functionality and a closer approximation to natural sensory experiences for individuals with limb differences.

2.
Front Hum Neurosci ; 18: 1338453, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38952645

RESUMO

Introduction: As robot teleoperation increasingly becomes integral in executing tasks in distant, hazardous, or inaccessible environments, operational delays remain a significant obstacle. These delays, inherent in signal transmission and processing, adversely affect operator performance, particularly in tasks requiring precision and timeliness. While current research has made strides in mitigating these delays through advanced control strategies and training methods, a crucial gap persists in understanding the neurofunctional impacts of these delays and the efficacy of countermeasures from a cognitive perspective. Methods: This study addresses the gap by leveraging functional Near-Infrared Spectroscopy (fNIRS) to examine the neurofunctional implications of simulated haptic feedback on cognitive activity and motor coordination under delayed conditions. In a human-subject experiment (N = 41), sensory feedback was manipulated to observe its influences on various brain regions of interest (ROIs) during teleoperation tasks. The fNIRS data provided a detailed assessment of cerebral activity, particularly in ROIs implicated in time perception and the execution of precise movements. Results: Our results reveal that the anchoring condition, which provided immediate simulated haptic feedback with a delayed visual cue, significantly optimized neural functions related to time perception and motor coordination. This condition also improved motor performance compared to the asynchronous condition, where visual and haptic feedback were misaligned. Discussion: These findings provide empirical evidence about the neurofunctional basis of the enhanced motor performance with simulated synthetic force feedback in the presence of teleoperation delays. The study highlights the potential for immediate haptic feedback to mitigate the adverse effects of operational delays, thereby improving the efficacy of teleoperation in critical applications.

3.
J Multidiscip Healthc ; 17: 3043-3052, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38974374

RESUMO

Introduction: Shoulder proprioception is vital and this cross-sectional study investigated the association between glycemic control and shoulder joint proprioception in Type 2 Diabetes Mellitus (T2DM). Methods: A total of 120 participants, including 60 with T2DM and 60 healthy individuals, were assessed for shoulder joint position sense (JPS) using a digital inclinometer. The T2DM group exhibited significantly greater mean shoulder joint position errors in flexion (4.32° vs 2.15°), abduction, medial rotation, and lateral rotation compared to the healthy group (p < 0.001). Results: The study found significantly greater shoulder joint position errors in the T2DM group compared to the healthy group, highlighting notable proprioceptive deficits in individuals with T2DM. Additionally, a significant positive correlation was found between HbA1c levels and shoulder joint position errors in the T2DM group, suggesting a link between long-term glycemic control and proprioceptive accuracy. Discussion: The significant positive correlation between HbA1c levels and shoulder joint position errors suggests that poor glycemic control is associated with impaired proprioception in T2DM patients. This underscores the need for comprehensive management strategies to mitigate proprioceptive deficits and improve the quality of life in individuals with T2DM.

4.
Biol Cybern ; 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38884785

RESUMO

Silent hypoxemia, or "happy hypoxia," is a puzzling phenomenon in which patients who have contracted COVID-19 exhibit very low oxygen saturation ( SaO 2 < 80%) but do not experience discomfort in breathing. The mechanism by which this blunted response to hypoxia occurs is unknown. We have previously shown that a computational model of the respiratory neural network (Diekman et al. in J Neurophysiol 118(4):2194-2215, 2017) can be used to test hypotheses focused on changes in chemosensory inputs to the central pattern generator (CPG). We hypothesize that altered chemosensory function at the level of the carotid bodies and/or the nucleus tractus solitarii are responsible for the blunted response to hypoxia. Here, we use our model to explore this hypothesis by altering the properties of the gain function representing oxygen sensing inputs to the CPG. We then vary other parameters in the model and show that oxygen carrying capacity is the most salient factor for producing silent hypoxemia. We call for clinicians to measure hematocrit as a clinical index of altered physiology in response to COVID-19 infection.

5.
Biol Cybern ; 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38769189

RESUMO

Studying the nervous system underlying animal motor control can shed light on how animals can adapt flexibly to a changing environment. We focus on the neural basis of feeding control in Aplysia californica. Using the Synthetic Nervous System framework, we developed a model of Aplysia feeding neural circuitry that balances neurophysiological plausibility and computational complexity. The circuitry includes neurons, synapses, and feedback pathways identified in existing literature. We organized the neurons into three layers and five subnetworks according to their functional roles. Simulation results demonstrate that the circuitry model can capture the intrinsic dynamics at neuronal and network levels. When combined with a simplified peripheral biomechanical model, it is sufficient to mediate three animal-like feeding behaviors (biting, swallowing, and rejection). The kinematic, dynamic, and neural responses of the model also share similar features with animal data. These results emphasize the functional roles of sensory feedback during feeding.

6.
Arch Bone Jt Surg ; 12(4): 296-297, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38716179

RESUMO

Despite recent advancements in bionic upper limb prostheses technology, the rejection rate by users remains unacceptably high. Various factors contribute to this issue, such as limited functionality, complex control mechanisms, and discomfort, with most of these concerns being documented solely through self-assessment surveys. In this article, we introduce our proposed four components for an integrated bionic hand aimed at making it closely resemble a natural hand. These components include an integrated intramedullary stem, a kineticomyographic motor control system, sensory feedback for stereognosis, and sensory feedback for proprioception.

7.
Micromachines (Basel) ; 15(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38675291

RESUMO

The restoration of sensory feedback is one of the current challenges in the field of prosthetics. This work, following the analysis of the various types of sensory feedback, aims to present a prototype device that could be used both for implantable applications to perform PNS and for wearable applications, performing TENS, to restore sensory feedback. The two systems are composed of three electronic boards that are presented in detail, as well as the bench tests carried out. To the authors' best knowledge, this work presents the first device that can be used in a dual scenario for restoring sensory feedback. Both the implantable and wearable versions respected the expected values regarding the stimulation parameters. In its implantable version, the proposed system allows simultaneous and independent stimulation of 30 channels. Furthermore, the capacity of the wearable version to elicit somatic sensations was evaluated on healthy participants demonstrating performance comparable with commercial solutions.

8.
Semin Plast Surg ; 38(1): 10-18, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38495064

RESUMO

Limb amputations can be devastating and significantly affect an individual's independence, leading to functional and psychosocial challenges in nearly 2 million people in the United States alone. Over the past decade, robotic devices driven by neural signals such as neuroprostheses have shown great potential to restore the lost function of limbs, allowing amputees to regain movement and sensation. However, current neuroprosthetic interfaces have challenges in both signal quality and long-term stability. To overcome these limitations and work toward creating bionic limbs, the Neuromuscular Laboratory at University of Michigan Plastic Surgery has developed the Regenerative Peripheral Nerve Interface (RPNI). This surgical construct embeds a transected peripheral nerve into a free muscle graft, effectively amplifying small peripheral nerve signals to provide enhanced control signals for a neuroprosthetic limb. Furthermore, the RPNI has the potential to provide sensory feedback to the user and facilitate neuroprosthesis embodiment. This review focuses on the animal studies and clinical trials of the RPNI to recapitulate the promising trajectory toward neurobionics where the boundary between an artificial device and the human body becomes indistinct. This paper also sheds light on the prospects of the improvement and dissemination of the RPNI technology.

9.
J Neural Eng ; 21(2)2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38382104

RESUMO

Objective.Sensory feedback is critical for effectively controlling brain-machine interfaces and neuroprosthetic devices. Spinal cord stimulation (SCS) is proposed as a technique to induce artificial sensory perceptions in rodents, monkeys, and humans. However, to realize the full potential of SCS as a sensory neuroprosthetic technology, a better understanding of the effect of SCS pulse train parameter changes on sensory detection and discrimination thresholds is necessary.Approach.Here we investigated whether stimulation periodicity impacts rats' ability to detect and discriminate SCS-induced perceptions at different frequencies.Main results.By varying the coefficient of variation (CV) of interstimulus pulse interval, we showed that at lower frequencies, rats could detect highly aperiodic SCS pulse trains at lower amplitudes (i.e. decreased detection thresholds). Furthermore, rats learned to discriminate stimuli with subtle differences in periodicity, and the just-noticeable differences from a highly aperiodic stimulus were smaller than those from a periodic stimulus.Significance.These results demonstrate that the temporal structure of an SCS pulse train is an integral parameter for modulating sensory feedback in neuroprosthetic applications.


Assuntos
Interfaces Cérebro-Computador , Estimulação da Medula Espinal , Humanos , Ratos , Animais , Roedores , Estimulação da Medula Espinal/métodos , Sensação , Aprendizagem , Medula Espinal/fisiologia
10.
bioRxiv ; 2024 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-38405798

RESUMO

Regaining sensory feedback is pivotal for people living with limb amputation. Electrical stimulation of sensory fibers in peripheral nerves has been shown to restore focal percepts in the missing limb. However, conventional rectangular current pulses induce sensations often described as unnatural. This is likely due to the synchronous and periodic nature of activity evoked by these pulses. Here we introduce a fast-oscillating amplitude-modulated sinusoidal (FAMS) stimulation waveform that desynchronizes evoked neural activity. We used a computational model to show that sinusoidal waveforms evoke asynchronous and irregular firing and that firing patterns are frequency dependent. We designed the FAMS waveform to leverage both low- and high-frequency effects and found that membrane non-linearities enhance neuron-specific differences when exposed to FAMS. We implemented this waveform in a feline model of peripheral nerve stimulation and demonstrated that FAMS-evoked activity is more asynchronous than activity evoked by rectangular pulses, while being easily controllable with simple stimulation parameters. These results represent an important step towards biomimetic stimulation strategies useful for clinical applications to restore sensory feedback.

12.
Med ; 5(2): 118-125.e5, 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38340707

RESUMO

BACKGROUND: Recently, we reported the presence of phantom thermal sensations in amputees: thermal stimulation of specific spots on the residual arm elicited thermal sensations in their missing hands. Here, we exploit phantom thermal sensations via a standalone system integrated into a robotic prosthetic hand to provide real-time and natural temperature feedback. METHODS: The subject (a male adult with unilateral transradial amputation) used the sensorized prosthesis to manipulate objects and distinguish their thermal properties. We tested his ability to discriminate between (1) hot, cold, and ambient temperature objects, (2) different materials (copper, glass, and plastic), and (3) artificial versus human hands. We also introduced the thermal box and block test (thermal BBT), a test to evaluate real-time temperature discrimination during standardized pick-and-place tasks. FINDINGS: The subject performed all three discrimination tasks above chance level with similar accuracies as with his intact hand. Additionally, in all 15 sessions of the thermal BBT, he correctly placed more than half of the samples. Finally, the phantom thermal sensation was stable during the 13 recording sessions spread over 400 days. CONCLUSION: Our study paves the way for more natural hand prostheses that restore the full palette of sensations. FUNDING: This work was funded by the Bertarelli Foundation (including the Catalyst program); the Swiss National Science Foundation through the National Centre of Competence in Research (NCCR) Robotics; the European Union's Horizon 2020 research and innovation program; the Horizon Europe Research & Innovation Program; the Ministry of University and Research (MUR), National Recovery and Resilience Plan (NRRP); and the Tuscany Health Ecosystem.


Assuntos
Membros Artificiais , Membro Fantasma , Adulto , Humanos , Masculino , Retroalimentação , Mãos/fisiologia , Sensação
13.
Ann Biomed Eng ; 52(4): 982-996, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38246964

RESUMO

The purpose was to assess the effectiveness of three sliding tactile probes placed on the forelimb skin to provide proprioceptive feedback for the detection of hand gestures and discrimination of object size. Tactile contactors representing the first three fingers were driven along the proximodistal axis by linear servo motors. Twenty healthy subjects were involved in the gesture detection test, with 10 of them also participating in the object-size discrimination task. Motors were controlled by computer in the first four sessions of the gesture detection experiment, while the fifth session utilized a sensorized glove. Both the volar and dorsal sides of the forearm were examined. In the object-size discrimination experiment, the method was exclusively assessed on the volar surface under four distinct feedback conditions, including all fingers and each finger separately. The psychophysical data were further analyzed using a structural equation model (SEM) to evaluate the specific contributions of each individual contactor. Subjects consistently outperformed the chance level in detecting gestures. Performance improved up to the third session, with better results obtained on the volar side. The performances were similar in the fourth and fifth sessions. The just noticeable difference for achieving a 75% discrimination accuracy was found to be 2.90 mm of movement on the skin. SEM analysis indicated that the contactor for the index finger had the lowest importance in gesture detection, while it played a more significant role in object-size discrimination. However, all fingers were found to be significant predictors of subjects' responses in both experiments, except for the thumb, which was deemed insignificant in object-size discrimination. The study highlights the importance of considering the partial contribution of each degree of freedom in a sensory feedback system, especially concerning the task, when designing such systems.


Assuntos
Retroalimentação Sensorial , Gestos , Humanos , Animais , Retroalimentação Sensorial/fisiologia , Pele , Tato/fisiologia , Dedos/fisiologia , Membro Anterior
14.
J Back Musculoskelet Rehabil ; 37(3): 751-760, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38250754

RESUMO

BACKGROUND: Rowing-related low back disorders may occur from inconsistent technique, high trunk flexion and training volumes, overactivation of paraspinal muscles, and fatigue. OBJECTIVE: To examine if kinesiology tape (KT) affixed to the trunk dorsum affects muscular co-activation and neuromuscular control to limit dangerous rowing movements and associated injuries. METHODS: Participants (n= 18) completed two 2000 m rowing trials under BASELINE and KT conditions. KT was applied to the skin superficial to the paraspinals bilaterally with 60% pre-strain. Participants were instructed to minimize any sensation of tension. Whole body kinematics were obtained using inertial measurement units (IMUs), and surface electromyograms (EMGs) were recorded from trunk and lower extremity. Changes in joint range-of-motion (ROM) and co-activation indices (CAIs) were analyzed for shoulder, lumbar, hip, and knee. RESULTS: Responding participants (n= 5) were identified by reduced maximum lumbar flexion during the KT condition. As expected, significant differences occurred in maximum and minimum lumbar flexion/extension between responders and non-responders to KT. Additionally, there was significant reduction in mean trunk muscle co-activation in both those who did and did not respond to KT through reductions in maximum lumbar flexion. CONCLUSION: KT can be an effective at reducing mean trunk co-activation during a rowing trial in the flexed catch position. Variable responses suggest that further work is necessary to optimize the efficacy of sensory cues derived from KT during rowing movements.


Assuntos
Fita Atlética , Eletromiografia , Amplitude de Movimento Articular , Esportes Aquáticos , Humanos , Fenômenos Biomecânicos/fisiologia , Masculino , Esportes Aquáticos/fisiologia , Adulto Jovem , Feminino , Amplitude de Movimento Articular/fisiologia , Adulto , Atletas , Movimento/fisiologia , Músculo Esquelético/fisiologia
15.
J Hosp Infect ; 145: 210-217, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38272126

RESUMO

BACKGROUND: Compliance with the recommended 30 s drying time of alcohol-based hand rub (ABHR) is often suboptimal. To increase hand hygiene compliance at a neonatal intensive care unit (NICU), we installed an Incubator Traffic Light (ITL) system which shows 'green light' to open incubator doors after the recommended drying time. AIM: To measure the impact of this visual feedback system on NICU healthcare professionals' compliance with the recommended ABHR drying time. METHODS: Ten traffic light systems were installed on incubators at a NICU, five of which provided visual feedback, and five, serving as a control group, did not provide visual feedback. During a two-month period, the systems measured drying time between the moment of dispensing ABHR and opening the incubator's doors. The drying times of the incubators were compared with and without feedback. FINDINGS: Of the 6422 recorded hand hygiene events, 658 were valid for data analysis. Compliance with correct drying time reached 75% (N = 397/526) for incubators equipped with visual feedback versus 36% (N = 48/132; P < 0.0001) for incubators lacking this feature. CONCLUSION: The ITL improves compliance with the recommended 30 s ABHR drying time in a NICU setting.


Assuntos
Infecção Hospitalar , Higiene das Mãos , Recém-Nascido , Humanos , Unidades de Terapia Intensiva Neonatal , Retroalimentação , Retroalimentação Sensorial , Fidelidade a Diretrizes , Etanol , 2-Propanol , Incubadoras , Desinfecção das Mãos , Infecção Hospitalar/prevenção & controle
16.
Cognition ; 244: 105713, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38176155

RESUMO

A recent model of temporal control in speech holds that speakers use sensory feedback to control speech rate and articulatory timing. An experiment was conducted to assess whether there is evidence in support of this hypothesis by comparing durations of phrases in external speech (with sensory feedback) and internal speech (without sensory feedback). Phrase lengths were varied by including one to three disyllabic nouns in a target phrase that was always surrounded by overt speech. An inferred duration method was used to estimate the durations of target phrases produced internally. The results showed that internal speech is faster than external speech, supporting the hypothesis. In addition, the results indicate that there is a slow-down associated with transitioning between internal and external modes of production.


Assuntos
Percepção da Fala , Fala , Humanos , Retroalimentação , Idioma , Retroalimentação Sensorial
17.
Exp Physiol ; 109(1): 148-158, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37856330

RESUMO

Muscle spindles relay vital mechanosensory information for movement and posture, but muscle spindle feedback is coupled to skeletal motion by a compliant tendon. Little is known about the effects of tendon compliance on muscle spindle feedback during movement, and the complex firing of muscle spindles makes these effects difficult to predict. Our goal was to investigate changes in muscle spindle firing using added series elastic elements (SEEs) to mimic a more compliant tendon, and to characterize the accompanying changes in firing with respect to muscle-tendon unit (MTU) and muscle fascicle displacements (recorded via sonomicrometry). Sinusoidal, ramp-and-hold and triangular stretches were analysed to examine potential changes in muscle spindle instantaneous firing rates (IFRs) in locomotor- and perturbation-like stretches as well as serial history dependence. Added SEEs effectively reduced overall MTU stiffness and generally reduced muscle spindle firing rates, but the effect differed across stretch types. During sinusoidal stretches, peak and mean firing rates were not reduced and IFR was best-correlated with fascicle velocity. During ramp stretches, SEEs reduced the initial burst, dynamic and static responses of the spindle. Notably, IFR was negatively related to fascicle displacement during the hold phase. During triangular stretches, SEEs reduced the mean IFR during the first and second stretches, affecting the serial history dependence of mean IFR. Overall, these results demonstrate that tendon compliance may attenuate muscle spindle feedback during movement, but these changes cannot be fully explained by reduced muscle fascicle length or velocity, or MTU force.


Assuntos
Fusos Musculares , Músculo Esquelético , Fusos Musculares/fisiologia , Músculo Esquelético/fisiologia , Tendões/fisiologia , Movimento , Postura
18.
Scand J Med Sci Sports ; 34(1): e14531, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37916599

RESUMO

Various sensory feedback methods are considered important for motor learning, but the effect of each sensory feedback method on effective squat learning still needs to be clarified. This study aimed to investigate the effect of sensory feedback types on the acquisition and retention of a squat. A double-blinded, randomized controlled trial was carried out. Thirty-healthy people were recruited and randomly assigned to the visual feedback group (VFG = 10), tactile feedback group (TFG = 10), and control group (CG = 10). VFG received visual feedback through video data of the participant performing squats, and TFG received tactile feedback through manual contact with a physical therapist. Both groups received feedback on the movements that needed correction after each set was completed. CG maintained rest without receiving any feedback. The retro-reflexive marker, force plate, and electromyography were used to measure body angle, foot center of pressure (COP), and muscle activity. All assessments were measured to confirm a squat acquisition. VFG and TFG showed significant differences in neutral knee position (NKP), trunk forward lean (TFL), anterior knee displacement (AKD), and anteroposterior (AP) foot COP (p < 0.050). In addition, the acquisition was retained until 3 days later for NKP and a week later for TFL, AKD, and AP foot COP in VFG (p < 0.050), while the acquisition was not retained in TFG (p > 0.050). There was no statistically significant change in CG (p > 0.050). This study demonstrated that visual feedback positively affects the acquisition and retention of squats. Therefore, we recommend the use of visual feedback for squat acquisition and retention in exercise novices.


Assuntos
Retroalimentação Sensorial , Postura , Humanos , Retroalimentação Sensorial/fisiologia , Movimento/fisiologia , Articulação do Joelho , Eletromiografia
19.
J Neurophysiol ; 131(2): 304-310, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38116612

RESUMO

Motor performance is monitored continuously by specialized brain circuits and used adaptively to modify behavior on a moment-to-moment basis and over longer time periods. During vocal behaviors, such as singing in songbirds, internal evaluation of motor performance relies on sensory input from the auditory and vocal-respiratory systems. Sensory input from the auditory system to the motor system, often referred to as auditory feedback, has been well studied in singing zebra finches (Taeniopygia guttata), but little is known about how and where nonauditory sensory feedback is evaluated. Here we show that brief perturbations in air sac pressure cause short-latency neural responses in the higher-order song control nucleus HVC (used as proper name), an area necessary for song learning and song production. Air sacs were briefly pressurized through a cannula in anesthetized or sedated adult male zebra finches, and neural responses were recorded in both nucleus parambigualis (PAm), a brainstem inspiratory center, and HVC, a cortical premotor nucleus. These findings show that song control nuclei in the avian song system are sensitive to perturbations directly targeted to vocal-respiratory, or viscerosensory, afferents and support a role for multimodal sensory feedback integration in modifying and controlling vocal control circuits.NEW & NOTEWORTHY This study presents the first evidence of sensory input from the vocal-respiratory periphery directly activating neurons in a motor circuit for vocal production in songbirds. It was previously thought that this circuit relies exclusively on sensory input from the auditory system, but we provide groundbreaking evidence for nonauditory sensory input reaching the higher-order premotor nucleus HVC, expanding our understanding of what sensory feedback may be available for vocal control.


Assuntos
Tentilhões , Animais , Masculino , Tentilhões/fisiologia , Aprendizagem/fisiologia , Tronco Encefálico , Retroalimentação Sensorial , Vocalização Animal/fisiologia
20.
Exp Brain Res ; 242(2): 403-416, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38135819

RESUMO

Foot orthoses (FO) are a commonly prescribed intervention to alter foot function during walking although their effects have been primarily studied in the extrinsic muscles of the foot. Furthermore, enhancing sensory feedback under the foot sole has been recently shown to alter extrinsic muscle activity during gait; however, the effects of FOs with enhanced sensory feedback on plantar intrinsic foot muscles (PIFMs) remain unknown. Thus, the purpose of this study was to investigate the effect of FOs with and without sensory facilitation on PIFM activity during locomotion. Forty healthy adults completed a series of gait trials in non-textured and textured FOs when walking over hard and soft flooring. Outcome measures included bilateral joint kinematics and electromyography (EMG) of four PIFMs. Results of this study highlight the distinct onset and cessations of each PIFM throughout the stance phase of gait. PIFMs remained active during mid-stance when wearing FOs and textured FOs facilitated muscle activity across the stance phase of gait. Increasing cutaneous input from foot sole skin, via the addition of texture under the foot sole, appears to alter motor-neuron pool excitation of PIFMs. Future academics are encouraged to increase our understanding on which pathologies, diseases, and/or medical conditions would best benefit from textured FOs.


Assuntos
, Músculo Esquelético , Adulto , Humanos , Pé/fisiologia , Músculo Esquelético/fisiologia , Locomoção , Caminhada/fisiologia , Marcha/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...