Cont Lens Anterior Eye ; : 102159, 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38851944

RESUMO

OBJECTIVE: To explore the changes in microcirculation and microvasculature of the bulbar conjunctiva during the short-term wearing of the scleral lenses (ScCL). And investigate the factors affecting the microcirculation and microvasculature of the bulbar conjunctiva. METHODS: In this prospective cross-sectional study, functional slit lamp biomicroscopy (FSLB) was used to image the ocular surface microcirculation and microvascular images at two different sites (under the area of ScCL and outside of the area of ScCL) before (baseline) and during the wearing of ScCL at 0 h, 1 h, 2 h and 3 h. Anterior segment optical coherence tomography (AS-OCT) (RTVue, Optovue Inc, USA) was also used to image central post-lens tear film (PoLTF) and the morphology changes of the conjunctiva under the landing zone at the same time period. The semi-automatic quantification of microcirculation and microvasculature including vessel density (Dbox), vessel diameter (D), axial blood flow velocity (Va) and blood flow volume (Q). And the morphological changes of conjunctiva and PoLTF fogging grading were evaluated manually. The changes in the microcirculation and microvasculature of the ocular surface, PoLTF fogging grade and conjunctival morphology were compared before and during the ScCL wearing at different time periods, and the relationship between them was analyzed. RESULTS: Nineteen eyes (11 right eyes, 8 left eyes) were analyzed in this study. Outside of the area of ScCL, the Dbox before wearing lenses was less than that at 0 h (P = 0.041). The Q at baseline was greater than that after 1 h ScCL wearing (P = 0.026). Under the area of the ScCL, the Q at 1 h was less than that at baseline and 3 h. During the ScCL wearing, statistically significant conjunctival morphology changes were found among different time stages (baseline (0 µm), 0 h (113.18 µm), 2 h (138.97 µm), 3 h (143.83 µm) (all P <0.05). Outside the area of the ScCL, the morphology changes of the conjunctiva were negatively correlated with the changes of Va (P<0.001,r = -0.471) and Q (P = 0.003,r = -0.348),but positively correlated with the Dbox (P = 0.001,r = 0.386). Under the area of ScCL, the morphology changes of the conjunctiva were negatively correlated with the Q (P = 0.012, r = -0.291). The fogging grade was positively correlated with the Q under the area of the ScCL (P = 0.005, r = 0.331). CONCLUSIONS: The microcirculation and microvasculature of the ocular surface and conjunctival morphology were changed after wearing ScCL in wearers, which indicated that the microvascular responses happened in the ScCL wearers and the severity of microvascular responses of the ocular surface related to the morphology changes of the conjunctiva. The quantification methods and findings in this study provide clues for the safety of ScCL wearing and may supervise the health of the wearer's ocular surface.

2.
Clin Case Rep ; 12(4): e8690, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38562576

RESUMO

A corneal stroma circular ring has captured by smartphone adaptor slit lamp camera after smile for 1 week.

3.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(2): 232-236, 2024 Mar 30.
Artigo em Chinês | MEDLINE | ID: mdl-38605628

RESUMO

In order to realize the diagnosis of slit lamp in cross-regional patients and improve the real-time and convenience of diagnosis, a remote slit lamp diagnosis platform based on Internet of Things (IoT) technology is designed. Firstly, the feasibility of remote slit lamp is analyzed. Secondly, the IoT platform architecture of doctor/server/facility (D/S/F) is proposed and a remote slit lamp is designed. Finally, the performance of the remote slit lamp diagnostic platform is tested. The platform solves the communication problem of distributed slit lamps and realizes respectively numerical control of multi-area slit lamp by multi-eye experts. The test results show that the remote control delay of the platform is less than 20 ms, which supports multiple experts to diagnose multiple patients separately.


Assuntos
Internet das Coisas , Lâmpada de Fenda , Humanos , Tecnologia
4.
Cureus ; 16(4): e57986, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38606028

RESUMO

Background This study aimed to investigate medical students' perspectives regarding the ease and utility of smartphone slit-lamp photography. Methodology In this prospective experimental study, fourth and fifth-year medical students who were in or had finished ophthalmology rotation were included to attempt slit-lamp smartphone anterior segment photography on adult patients after a brief hands-on instruction course. Each medical student attempted to record five supervised slit-lamp videos of the anterior segment of five patients using the described adapter and their own smartphone. The time taken until photography was calculated for each attempt. After the fifth attempt, each medical student rated the ease of the use of this method of slit-lamp photography as well as their perspective regarding its utility as a potential means of medical education and telemedical consultations on a five-point Likert scale. Results A total of 33 medical students participated, with each successfully recording five slit-lamp examinations using their smartphones. The time used for the application of the adapter until the image capture ranged from 6 to 278 seconds (average = 39.51 ± 34.7 seconds) and markedly improved by the fifth attempt (30.5 ± 25.7 seconds) compared to the first attempt (67.3 ± 49.3 seconds). Learning this skill was perceived to be relatively easy (2.2 ± 1), with high potential in clinical education (4.6 ± 0.75) and teleconsultations (4.7 ± 0.65). Conclusions Smartphone slit-lamp photography is a relatively easy process. It can be quickly acquired by medical students and has the potential to enhance their medical education and telemedical consultation capabilities.

5.
J Med Imaging (Bellingham) ; 11(2): 026003, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38606184

RESUMO

Purpose: Timely detection and treatment of visual impairments and age-related eye diseases are essential for maintaining a longer, healthier life. However, the shortage of appropriate medical equipment often impedes early detection. We have developed a portable self-imaging slit-light device utilizing NIR light and a scanning mirror. The objective of our study is to assess the accuracy and compare the performance of our device with conventional nonportable slit-lamp microscopes and anterior segment optical coherence tomography (AS-OCT) for screening and remotely diagnosing eye diseases, such as cataracts and glaucoma, outside of an eye clinic. Approach: The NIR light provides an advantage as measurements are nonmydriatic and less traumatic for patients. A cross-sectional study involving Japanese adults was conducted. Cataract evaluation was performed using photographs captured by the device. Van-Herick grading was assessed by the ratio of peripheral anterior chamber depth to peripheral corneal thickness, in addition to the iridocorneal angle using Image J software. Results: The correlation coefficient between values obtained by AS-OCT, and our fabricated portable scanning slit-light device was notably high. The results indicate that our portable device is equally reliable as the conventional nonportable slit-lamp microscope and AS-OCT for screening and evaluating eye diseases. Conclusions: Our fabricated device matches the functionality of the traditional slit lamp, offering a cost-effective and portable solution. Ideal for remote locations, healthcare facilities, or areas affected by disasters, our scanning slit-light device can provide easy access to initial eye examinations and supports digital eye healthcare initiatives.

6.
Cureus ; 16(2): e53698, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38455825

RESUMO

BACKGROUND: The healthcare industry has one of the highest rates of work-related injuries. Ophthalmologists are at particularly high risk for developing musculoskeletal disorders (MSDs), which are often the result of repetitive movements, such as performing slit lamp examinations. Previous studies used the Rapid Entire Body Assessment (REBA) scale to determine the ergonomic risk of a particular task. Higher REBA scores correlate with increased risk of injury, which ranges from negligible risk (1) to very high risk (11+). OBJECTIVE: Given the long-term implications of repetitive examinations by ophthalmologists, this study aims to describe the average ergonomic risk posed to residents using the REBA scale. METHODS: This descriptive case study assessed four ophthalmology residents performing slit lamp examinations between September 2022 and February 2023. Photographs were taken of residents performing slit lamp examinations. Total REBA scores, Score A, Score B, and the REBA scores for each participant were calculated and compared. RESULTS: The average REBA score across all participants was 4.59 (SD±0.89). The highest score was 7.00 and the lowest was 3.00. The average Score A, representing posture for the head, leg, and trunk, was 3.54 (SD±0.74) and the average Score B, representing posture for the upper arm, lower arm, and wrist, was 3.18 (SD±1.22). CONCLUSION: Our study found that residents are at increased risk for developing MSDs. Furthermore, variation in REBA scores between residents indicates that not all residents are at equal ergonomic risk. This highlights an opportunity for ophthalmology residency programs to implement ergonomics training into their curriculum.

7.
Vet Ophthalmol ; 27(3): 286-289, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38409733

RESUMO

A novel, simple, and inexpensive model for teaching depth of lesions within the cornea using slit lamp biomicroscopy to veterinary students, ophthalmology residents, and general clinicians with access to a slit lamp biomicroscope is described. Using common laboratory items, this method can be created in any clinic and can be used to teach and quiz students through independent study with objective self-testing achieved.


Assuntos
Doenças da Córnea , Educação em Veterinária , Microscopia com Lâmpada de Fenda , Animais , Microscopia com Lâmpada de Fenda/veterinária , Microscopia com Lâmpada de Fenda/instrumentação , Educação em Veterinária/métodos , Doenças da Córnea/veterinária , Doenças da Córnea/diagnóstico , Oftalmologia/educação , Lâmpada de Fenda/veterinária , Humanos , Córnea/patologia
8.
Arch Soc Esp Oftalmol (Engl Ed) ; 99(7): 309-311, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38401596

RESUMO

Entropion, a common malposition of the eyelid, can lead to trichiasis and corneal damage. This article presents a clinical case in which, following initial surgery to correct entropion, the use of a dermatological punch was chosen to definitively eliminate persistent trichiasis. This relatively unknown yet effective approach proved to be a quick and straightforward alternative with positive outcomes, emphasizing the importance of considering innovative approaches to recurrent challenges in clinical practice.


Assuntos
Entrópio , Triquíase , Humanos , Triquíase/cirurgia , Entrópio/cirurgia , Feminino , Masculino , Pestanas
9.
Diagnostics (Basel) ; 14(3)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38337832

RESUMO

PURPOSE: We aimed to evaluate the feasibility of using a novel device, the Smart Eye Camera (SEC), for assessing tear meniscus height (TMH) after fluorescein staining and the agreement of the results with measurements obtained using standard slit lamp examination. METHODS: TMH was assessed using both SEC and conventional slit lamp examination. The images were analyzed using the software ImageJ 1.53t (National Institutes of Health, Bethesda, MD, USA). A common measurement unit scale was established based on a paper strip, which was used as a calibration marker to convert pixels into metric scale. A color threshold was applied using uniform parameters for brightness, saturation, and hue. The images were then binarized to black and white to enhance the representation of the tear menisci. A 2 mm area around the upper and lower meniscus in the central eye lid zone was selected and magnified 3200 times to facilitate manual measurement. The values obtained using SEC were compared with those obtained with a slit lamp. RESULTS: The upper and lower TMH values measured using the SEC were not statistically different from those obtained with a slit lamp (0.209 ± 0.073 mm vs. 0.235 ± 0.085, p = 0.073, and 0.297 ± 0.168 vs. 0.260 ± 0.173, p = 0.275, respectively). The results of Bland-Altman analysis demonstrated strong agreement between the two instruments, with a mean bias of -0.016 mm (agreement limits: -0.117 to 0.145 mm) for upper TMH and 0.031 mm (agreement limits: -0.306 to 0.368 mm) for lower TMH. CONCLUSIONS: The SEC demonstrated sufficient validity and reliability for assessing TMH in healthy eyes in a clinical setting, demonstrating concordance with the conventional slit lamp examination.

10.
Exp Eye Res ; 238: 109739, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38042515

RESUMO

Corneal alkali burns often occur in industrial production and daily life, combined with infection, and may cause severe eye disease. Oxidative stress and neovascularization (NV) are important factors leading to a poor prognosis. URP20 is an antimicrobial peptide that has been proven to treat bacterial keratitis in rats through antibacterial and anti-NV effects. Therefore, in this study, the protective effect and influence mechanism of URP20 were explored in a rat model of alkali burn together with pathogenic bacteria (Staphylococcus aureus and Escherichia coli) infection. In addition, human umbilical vein endothelial cells (HUVECs) and human corneal epithelial cells (HCECs) were selected to verify the effects of URP20 on vascularization and oxidative stress. The results showed that URP20 treatment could protect corneal tissue, reduce corneal turbidity, and reduce the NV pathological score. Furthermore, URP20 significantly inhibited the expression of the vascularization marker proteins VEGFR2 and CD31. URP20 also reduced the migration ability of HUVECs. In terms of oxidative stress, URP20 significantly upregulated SOD and GSH contents in corneal tissue and HCECs (treated with 200 µM H2O2) and promoted the expression of the antioxidant protein Nrf2/HO-1. At the same time, MDA and ROS levels were also inhibited. In conclusion, URP20 could improve corneal injury combined with bacterial infection in rats caused by alkali burns through antibacterial, anti-NV, and antioxidant activities.


Assuntos
Infecções Bacterianas , Queimaduras Químicas , Lesões da Córnea , Neovascularização da Córnea , Queimaduras Oculares , Ratos , Humanos , Animais , Queimaduras Químicas/complicações , Queimaduras Químicas/tratamento farmacológico , Queimaduras Químicas/metabolismo , Neovascularização da Córnea/metabolismo , Antioxidantes/farmacologia , Antioxidantes/uso terapêutico , Peróxido de Hidrogênio/farmacologia , Neovascularização Patológica/metabolismo , Lesões da Córnea/tratamento farmacológico , Células Endoteliais da Veia Umbilical Humana , Antibacterianos/uso terapêutico , Antibacterianos/farmacologia , Queimaduras Oculares/induzido quimicamente , Queimaduras Oculares/tratamento farmacológico , Queimaduras Oculares/patologia , Modelos Animais de Doenças , Álcalis/toxicidade
11.
International Eye Science ; (12): 136-139, 2024.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1003522

RESUMO

AIM: To explore a more convenient and accurate method for evaluating the anterior chamber angle width based on the Van Herick method.METHODS:A total of 58 patients(69 eyes)with age-related cataract who visited our hospital between January and December 2021 were included. They were divided into the chamber angle width ≥1/2 corneal thickness(CT)group(44 eyes of 37 cases)and <1/2CT group(25 eyes of 21 cases)according to the Van Herick method. The central anterior chamber depths and the peripheral anterior chamber angle degrees were measured by ultrasound biomicroscopy.RESULTS: There were statistically significant differences in central anterior chamber depth between the two groups(2.64±0.27 mm vs. 2.23±0.29 mm, P<0.01), and the differences of chamber angle degrees of quadrants of superior, temporal, inferior and nasal compared between two groups were all statistically significant(P<0.01). The difference of chamber angle degrees of quadrants of superior and inferior in chamber angle width ≥1/2CT group was not statistically significant(P>0.05), while the differences of chamber angle degrees of other quadrants were all statistically significant(P<0.05). The differences of chamber angle degrees of quadrants of superior and nasal, temporal and the chamber angle degrees of quadrants of inferior and temporal were all statistically significant in chamber angle width <1/2CT group(P<0.05).CONCLUSION: In the overall evaluation of the anterior chamber angle, it would be more simple, fast and accurate when evaluating the temporal chamber angle width and inferior quadrant of chamber angle width by using the Van Herick method under silt lamp.

12.
Quant Imaging Med Surg ; 13(10): 6778-6788, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37869308

RESUMO

Background: Corneal neovascularization (CoNV) is a common sign in anterior segment eye diseases, the level of which can indicate condition changes. Current CoNV evaluation methods are time-consuming and some of them rely on equipment which is not widely available in hospitals. Thus, a fast and efficient evaluation method is now urgently required. In this study, a deep learning (DL)-based model was developed to automatically segment and evaluate CoNV using anterior segment images from a slit-lamp microscope. Methods: A total of 80 cornea slit-lamp photographs (from 80 patients) with clinically manifested CoNV were collected from December 2021 to July 2022 at Tianjin Medical University Eye Hospital. Of these, 60 images were manually labelled by ophthalmologists using ImageJ software to train the vessel segmentation network IterNet. To evaluate the performance of this automated model, evaluation metrics including accuracy, precision, area under the receiver operating characteristic (ROC) curve (AUC), and F1 score were calculated between the manually labelled ground truth and the automatic segmentations of CoNV of 20 anterior segment images. Furthermore, the vessels pixel count was automatically calculated and compared with the manually labelled results to evaluate clinical usability of the automated segmentation network. Results: The IterNet model achieved an AUC of 0.989, accuracy of 0.988, sensitivity of 0.879, specificity of 0.993, area under precision-recall of 0.921, and F1 score of 0.879. The Bland-Altman plot between manually labelled ground truth and automated segmentation results produced a concordance correlation coefficient of 0.989, 95% limits of agreement between 865.4 and -562.4, and the vessels pixel count's Pearson coefficient of correlation was 0.981 (P<0.01). Conclusions: The fully automated network model IterNet provides a time-saving and efficient method to make a quantitative evaluation of CoNV using slit-lamp anterior segment images. This method demonstrates great value and clinical application potential for patient care and future research.

13.
J Acad Ophthalmol (2017) ; 15(2): e215-e222, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37766880

RESUMO

Purpose This article assesses the efficacy of an instructional video and model eye simulation for teaching slit lamp exam to medical students as compared to traditional preceptor teaching. Methods First through 4th year students from the University of California, San Francisco School of Medicine were recruited via email to participate in the study. Students were randomized into two groups. The experimental "model eye" group watched an instructional video on slit lamp exam, spent 10 minutes practicing on the model eye, then practiced for 25 minutes with a student partner. The control "preceptor teaching" group received 25 minutes of in-person preceptor teaching on slit lamp exam, then spent 25 minutes practicing with a student partner. Students were objectively assessed by a blinded grader who scored their examination skills with a 31-item checklist. Qualtrics surveys that measured student perceptions were distributed before and after the intervention. Results Seventeen medical students participated in the study. Students in the model eye group achieved higher mean objective assessment scores than students in the preceptor teaching group on skills relating to slit lamp set up (1.75, standard deviation [SD] = 0.50 and 1.50, SD = 0.80 out of 2 points, p = 0.03) and on the total score (1.69, SD = 0.6 and 1.48, SD = 0.8 out of 2 points, p < 0.01). Both groups reported a significant increase in their understanding of what a slit lamp is used for ( p < 0.01) and in their confidence using a slit lamp ( p < 0.01). All students felt their skills improved with the workshop, 94% found the workshop to be useful, and 88% enjoyed the workshop, with no intergroup differences on these metrics. Conclusion An instructional video combined with a simulation model is as effective as traditional preceptor teaching of the slit lamp exam. Such a teaching module may be considered as an adjunct to traditional methods.

14.
Indian J Ophthalmol ; 71(8): 2978-2983, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37530268

RESUMO

Purpose: To compare the slit-lamp method and wavefront aberrometry method based on outcomes of toric realignment surgeries. Settings: Tertiary care ophthalmic hospital. Design: Retrospective study. Methods: This study included all eyes undergoing toric intraocular lens (TIOL) realignment surgery between January 2019 and December 2021 for which TIOL axis assessment by slit-lamp method and wavefront aberrometry method was available. Data were retrieved from electronic medical records, and we documented demographics, uncorrected visual acuity (UCVA), subjective refraction, and TIOL axis by slit-lamp and wavefront aberrometry methods on postoperative day 1 and day 14. In patients with misalignment, TIOL was realigned to the original position in group 1 (27 patients) and to an axis based on calculations provided by wavefront aberrometer in group 2 (25 patients). Post-realignment surgery, UCVA, subjective refraction, and TIOL axis by slit-lamp and wavefront aberrometry methods were assessed and analyzed. Results: We analyzed 52 eyes and found that the mean preoperative misalignment with the slit-lamp method (44.9° ±20.0°) and wavefront aberrometry (47.1° ±19.5°) was similar. The corresponding degrees of misalignment post-TIOL repositioning surgeries were 5.2° ±5.2° (slit-lamp method) and 4.7° ±5.1° (wavefront aberrometry) (P = 0.615). Both groups showed significant improvement in median log of minimum angle of resolution (logMAR) UCVA and reduction in median refractive cylinder. Conclusions: Slit-lamp method is as good as wavefront aberrometer method to assess TIOL axis. Toric realignment surgery is found to be safe, and realigning TIOL based on either slit-lamp method or wavefront aberrometer method equally improved UCVA and decreased residual refractive cylinder.


Assuntos
Astigmatismo , Aberrações de Frente de Onda da Córnea , Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular/métodos , Aberrometria , Estudos Retrospectivos , Facoemulsificação/métodos , Astigmatismo/diagnóstico , Astigmatismo/cirurgia , Estudos Prospectivos , Refração Ocular , Córnea
15.
Int J Ophthalmol ; 16(8): 1237-1242, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37602355

RESUMO

AIM: To assess the performance of a bespoke software for automated counting of intraocular lens (IOL) glistenings in slit-lamp images. METHODS: IOL glistenings from slit-lamp-derived digital images were counted manually and automatically by the bespoke software. The images of one randomly selected eye from each of 34 participants were used as a training set to determine the threshold setting that gave the best agreement between manual and automatic grading. A second set of 63 images, selected using randomised stratified sampling from 290 images, were used for software validation. The images were obtained using a previously described protocol. Software-derived automated glistenings counts were compared to manual counts produced by three ophthalmologists. RESULTS: A threshold value of 140 was determined that minimised the total deviation in the number of glistenings for the 34 images in the training set. Using this threshold value, only slight agreement was found between automated software counts and manual expert counts for the validating set of 63 images (κ=0.104, 95%CI, 0.040-0.168). Ten images (15.9%) had glistenings counts that agreed between the software and manual counting. There were 49 images (77.8%) where the software overestimated the number of glistenings. CONCLUSION: The low levels of agreement show between an initial release of software used to automatically count glistenings in in vivo slit-lamp images and manual counting indicates that this is a non-trivial application. Iterative improvement involving a dialogue between software developers and experienced ophthalmologists is required to optimise agreement. The results suggest that validation of software is necessary for studies involving semi-automatic evaluation of glistenings.

16.
Eye Vis (Lond) ; 10(1): 36, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37653457

RESUMO

BACKGROUND: This study aimed to compare the complication rates of epithelium-off corneal cross-linking (epi-off CXL) performed in an office-based setting with those of epi-off CXL performed in an operating room. METHODS: A retrospective cohort study, comprising 501 consecutive epi-off CXL procedures, performed in a non-sterile procedure room without laminar flow ventilation at the ELZA Institute in Zurich, Switzerland, between November 2015 and October 2021, was conducted. RESULTS: No cases of postoperative infectious keratitis were observed, while sterile infiltrates occurred in 10 out of 501 (2.00%) patients, all of whom responded well to topical steroid therapy. Delayed epithelialization (> 7 days) occurred in 14 out of 501 (2.79%) patients. No other adverse events were noted. CONCLUSIONS: Office-based epi-off CXL does not appear to be associated with an increased risk of complications when compared to operating room settings.

17.
Arq. bras. oftalmol ; 86(4): 322-329, July-Sep. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1447374

RESUMO

ABSTRACT Purpose: This study aimed to use computational models for simulating the movement of respiratory droplets when assessing the efficacy of standard slit-lamp shield versus a new shield designed for increased clinician comfort as well as adequate protection. Methods: Simulations were performed using the commercial software Star-CCM+. Respiratory droplets were assumed to be 100% water in volume fraction with particle diameter distribution represented by a geometric mean of 74.4 (±1.5 standard deviation) μm over a 4-min duration. The total mass of respiratory droplets expelled from patients' mouths and droplet accumulation on the manikin were measured under the following three conditions: with no slit-lamp shield, using the standard slit-lamp shield, and using our new proposed shield. Results: The total accumulated water droplet mass (kilogram) and percentage of expelled mass accumulated on the shield under the three aforementioned conditions were as follows: 5.84e-10 kg (28% of the total weight of particle emitted that settled on the manikin), 9.14e-13 kg (0.045%), and 3.19e-13 (0.015%), respectively. The standard shield could shield off 99.83% of the particles that would otherwise be deposited on the manikin, which is comparable to 99.95% for the proposed design. Conclusion: Slit-lamp shields are effective infection control tools against respiratory droplets. The proposed shield showed comparable effectiveness compared with conventional slit-lamp shields, but with potentially enhanced ergonomics for ophthalmologists during slit-lamp examinations.


RESUMO Introdução: Os oftalmologistas têm alto risco de contrair a doença do Coronavírus-19 devido à proximidade com os pacientes durante os exames com lâmpada de fenda. Usamos um modelo de computação para avaliar a eficácia das proteções para lâmpadas de fenda e propusemos uma nova proteção ergonomicamente projetada. Métodos: As simulações foram realizadas no software comercial Star-CCM +. Os aerossóis de gotículas foram considerados 100% de água em fração de volume com distribuição de diâmetro de partícula representada por uma média geométrica de 74,4 ± 1,5 (desvio padrão) μm ao longo de uma duração de quatro minutos. A massa total de gotículas de água acumulada no manequim e a massa expelida pela boca do paciente foram medidas em três condições diferentes: 1) Sem protetor de lâmpada de fenda, 2) com protetor padrão, 3) Com o novo protetor proposto. Resultados: A massa total acumulada das gotas de água (kg) e a porcentagem da massa expelida acumulada no escudo para cada uma das respectivas condições foram; 1) 5,84e-10 kg (28% do peso total da partícula emitida que assentou no manequim), 2) 9,14e-13 kg (0,045%), 3,19e-13 (0,015%). O escudo padrão foi capaz de proteger 99,83% das partículas que, de outra forma, teriam se depositado no manequim, o que é semelhante a 99,95% para o projeto proposto. Conclusão: Protetores com lâmpada de fenda são ferramentas eficazes de controle de infecção contra gotículas respiratórias. O protetor proposto mostrou eficácia comparável em comparação com os protetores de lâmpada de fenda convencionais, mas potencialmente oferece uma melhor ergonomia para oftalmologistas durante o exame de lâmpada de fenda.

18.
Indian J Ophthalmol ; 71(6): 2416-2420, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37322651

RESUMO

Purpose: Diseases affecting the cornea are a major cause of corneal blindness globally. The pressing issue we are facing today is the lack of diagnostic devices in rural areas to diagnose these conditions. The aim of the study is to establish sensitivity and accuracy of smartphone photography using a smart eye camera (SEC) in ophthalmologic community outreach programs. Methods: In this pilot study, a prospective non-randomized comparative analysis of inter-observer variability of anterior segment imaging recorded using an SEC was performed. Consecutive 100 patients with corneal pathologies, who visited the cornea specialty outpatient clinic, were enrolled. They were examined with a conventional non-portable slit lamp by a cornea consultant, and the diagnoses were recorded. This was compared with the diagnoses made by two other consultants based on SEC videos of the anterior segment of the same 100 patients. The accuracy of SEC was accessed using sensitivity, specificity, PPV, and NPV. Kappa statistics was used to find the agreement between two consultants by using STATA 17.0 (Texas, USA). Results: There was agreement between the two consultants to diagnosing by using SEC. Above 90% agreements were found in all the diagnoses, which were statistically significant (P-value < 0.001). More than 90% sensitivity and a negative predictive value were found. Conclusion: SEC can be used successfully in the community outreach programs like field visits, eye camps, teleophthalmology, and community centers, where either a clinical setup is lacking or ophthalmologists are not available.


Assuntos
Oftalmologia , Telemedicina , Humanos , Oftalmologia/métodos , Smartphone , Estudos Prospectivos , Relações Comunidade-Instituição , Projetos Piloto , Telemedicina/métodos , Fotografação/métodos
19.
Ophthalmol Ther ; 12(4): 2171-2186, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37294522

RESUMO

INTRODUCTION: Simulation training has an important role in medical education. In ophthalmology, simulation-based training has been shown to be significantly effective for surgical and diagnostic training in direct and indirect ophthalmoscopy. In this study, we analysed the effects of simulator-based slit lamp training. METHODS: In this prospective controlled trial, medical students in their eighth semester at Saarland University Medical Center (n = 24) who had attended a 1-week ophthalmological internship were randomized into two groups: The traditional group (n = 12) was examined directly after the 1-week internship; the simulator group (n = 12) was trained with the slit lamp simulator before passing an objective structured clinical examination (OSCE). A masked ophthalmological faculty trainer assessed the students' slit lamp skills (maximum total score 42 points [pts]): preparation (5 pts), clinical examination (9.5 pts), assessment of findings (9.5 pts), diagnosis (3 pts), commentary on the examination approach (8 pts), measurement of structures (2 pts) and recognition of five diagnoses (5 pts). All students completed post-assessment surveys. Examination grades and survey responses were compared between the groups. RESULTS: The overall performance of the slit lamp OSCE was significantly better (p < 0.001) in the simulator group than in the traditional group (29.75 [7.88] vs. 17.00 [4.75]) with significantly higher scores for the preparation and assessment of slit lamp controls (5.0 [0.0] vs. 3.0 [3.5]; p = 0.008) and localization of relevant structures (6.75 [3.13] vs. 4.0 [1.5]; p = 0.008). Consistently higher scores, but not significant, were assigned for the description of structures found (4.5 [3.38] vs. 3.25 [2.13]; p = 0.09) and the correct diagnosis (3.0 [0.0] vs. 3.0 [0.0]; p = 0.48). Surveys reflected the students' subjectively perceived knowledge gain during the simulator training for slit lamp illumination techniques (p = 0.002), recognition (p < 0.001), and assessment of the correct localization of pathologies (p < 0.001). CONCLUSION: Slit lamp examination is an important diagnostic method in ophthalmology. Simulator-based training improved students' examination techniques for localizing anatomical structures and pathological lesions. The transfer of theoretical knowledge into practice can be achieved in a stress-free atmosphere.

20.
Indian J Ophthalmol ; 71(5): 2222-2224, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37202954

RESUMO

Fundus photography is an arduous task as it involves using 90 D in one hand and a smartphone attached on an eyepiece of a slit-lamp biomicroscope in the other hand. Similarly, with a 20 D lens, the filming distance is adjusted by moving the lens or mobile forward or backward, which makes it difficult to adjust and focus the image in busy ophthalmology outpatient departments (OPDs). Moreover, fundus camera costs thousands of dollars. Authors describe a novel technique of performing fundus photography with a 20 D lens and a universal slit-lamp-mounted mobile adapter made from trash. By the use of this simple, yet frugal innovation, primary care physicians or ophthalmologists without a fundus camera can easily snap a fundus photo and subject it to digital analysis by retina specialists across the world. This will help in simultaneous ocular examination and fundus photos taken via mounted 20 D on a slit lamp itself and also reduce the need for unnecessary retina referrals to tertiary eye care centers.