Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.135
Filtrar
1.
J Chromatogr A ; 1730: 465124, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38959657

RESUMO

Polymer monoliths can be polymerised within different molds, but limited options are available for the preparation of free-standing polymer monoliths for analytical sample preparation, and in particular, solid-phase extraction (SPE). Commercial melamine-formaldehyde sponges can be used as supports for the preparation of polymer monoliths, due its flexibility, giving various shapes to monoliths. Herein, the crosslinker/porogen ratio of highly porous sponge-nested divinylbenzene (DVB) polymer monoliths has been evaluated. Monoliths prepared using different crosslinker/porogen ratios were applied to the extraction of bisphenol F, bisphenol A, bisphenol AF, and bisphenol B. Monoliths containing 50 wt % DVB and 50 wt % porogens presented the highest recovery of bisphenols. Under the optimised conditions, the developed method showed a linear range between 2.5 µg L-1 and 150 µg L-1 for BPA and BPAF, and between 5 µg L-1 and 150 µg L-1 for BPB and BPF. The limits of detection (LOD, S/N = 3) and limits of quantification (LOQ, S/N = 10) ranged from 0.36 µg L-1 to 1.09 µg L-1, and from 1.20 µg L-1 to 3.65 µg L-1, respectively. The recoveries for spiked bisphenols (10 µg L-1) in tap water and water contained in a polycarbonate containers were between 82 % and 114 %.

2.
J Chromatogr A ; 1730: 465130, 2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-38955130

RESUMO

This study describes the preparation of a cylindrical polymer foam column termed Chitosan/ß-Cyclodextrin/MIL-68(Al) (CS/ß-CD/MIL-68(Al)). An ice template-freeze drying technique was employed to prepare the CS/ß-CD/MIL-68(Al) foam column by embedding MIL-68(Al) in a polymer matrix comprising cross-linked chitosan (CS) and ß-cyclodextrin (ß-CD). The cylindrical CS/ß-CD/MIL-68(Al) foam was subsequently inserted into a syringe to develop a solid phase extraction (SPE) device. Without the requirement for an external force, the sample solution passed easily through the SPE column thanks to the porous structure of the CS/ß-CD/MIL-68(Al) foam column. Moreover, the CS/ß-CD/MIL-68(Al) foam column was thought to be a superior absorbent for SPE since it included the adsorptive benefits of CS, ß-CD, and MIL-68(Al). The SPE was utilized in conjunction with high-performance liquid chromatography to analyze six sulfonamides found in milk, urine, and water. With matrix effects ranging from 80.49 % to 104.9 % with RSD values of 0.4-14.0 %, the method showed high recoveries ranging from 80.6 to 107.4 % for water samples, 93.4-105.2 % for urine, and 87.4-100.9 % for milk. It also demonstrated good linearity in the range of 10-258 ng·mL-1 with the limits of detection ranging from 1.88 to 2.58 ng·mL-1. The cylindrical CS/ß-CD/MIL-68(Al) foam column prepared in this work offered several advantages, including its simple fabrication, excellent water stability, absence of pollutants, biodegradability, and reusability. It is particularly well-suited for SPE. Furthermore, the developed SPE method, employing CS/ß-CD/MIL-68(Al) foam column, is straightforward and precise, and its benefits, including affordability, ease of preparation, lack of specialized equipment, and solvent economy, underline its broad applicability for the pretreatment of aqueous samples.

3.
Drug Test Anal ; 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38978168

RESUMO

Previous liquid chromatography/mass spectrometry (LC/MS) methods for the detection of insulin and other similar peptide hormones in equine plasma relied on the use of antibody affinity extraction. As a result, these methods were not suitable for routine high-throughput analysis. A solid-phase extraction (SPE) method incorporating size exclusion as well as reversed-phase interactions allows the selective extraction of peptide hormones such as adrenocorticotropic hormone (ACTH), insulin and their synthetic analogues from equine plasma with approximately 80% extraction efficiencies. This extraction was combined with on-column derivatisation with acetic anhydride, followed by tryptic digestion and analysis by micro-LC/MSMS for high-sensitivity peptide hormone detection. The analysis of tryptic peptides provides greater sensitivity and more robust chromatography compared with the analysis of intact insulin and ACTH. For quantitative analysis, isotopically labelled internal standards of target peptides can be prepared in the laboratory through the use of deuterated acetic anhydride. The utility of the method was assessed for the analysis of ACTH and insulin in samples from horses suffering from pituitary pars intermedia dysfunction (PPID).

4.
J Chromatogr A ; 1730: 465139, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38970876

RESUMO

Adsorbents with good dispersibility and high efficiency are crucial for magnetic solid-phase extraction (MSPE). In this study, flower-like magnetic nanomaterials (F-Ni@NiO@ZnO2-C) were successfully prepared by calcination of metal-organic framework (MOF) precursors that was stacked by two-dimensional (2D) nanosheet. The synthesized F-Ni@NiO@ZnO2-C has a flower-like layered structure with a large amount of pore space, promoting the rapid diffusion of targets. In addition, Zn2+ doped in MOF precursors was still retained that further produced strong metal chelation with targets. The unique structure of F-Ni@NiO@ZnO2-C was used as MSPE adsorbent, and combined with high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) for extraction of three microcystins (MCs) detection, including microcystin-LR (MC-LR), microcystin-RR (MC-RR), microcystin-YR (MC-YR). The resulting method has a detection limit of 0.2-1.0 pg mL-1, a linear dynamic range of 0.6-500.0 pg mL-1 and has good linearity (R ≥ 0.9996). Finally, the established method was applied to the highly selective enrichment of MCs in biological samples, successfully detecting trace amounts of MCs (8.4-15.0 pg mL-1) with satisfactory recovery rates (83.7-103.1 %). The results indicated that flower-like magnetic F-Ni@NiO@ZnO2-C was a promising adsorbent, providing great potential for the determination of trace amounts of MCs in biological samples.

5.
Sci Total Environ ; 946: 174382, 2024 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-38955278

RESUMO

In this study, a comprehensive and sensitive method for the simultaneous detection of 17 opioids (OPs) and their human metabolites in wastewater using high-performance liquid chromatography coupled to tandem mass spectrometry was validated. The chromatographic separations of opioids were carried out on a Kinetex® Biphenyl column (1.7 µm, 100 Å, 50 × 2.1 mm). A synthetic wastewater approach was used for recovery studies to mimic a contaminant-free matrix. Two solid-phase extraction (SPE) sorbents (hydrophilic-lipophilic balance and mixed mode with the previous phase and a weak cationic exchange) were studied to optimize sample treatment and obtain higher recoveries. The mixed mode was chosen because the recoveries of 17 target analytes at three spiked concentrations (25, 50, and 100 ng mL-1) were > 80 % for 75 % of the analytes in a simulated wastewater. The intra- and inter-day relative standard deviations (RSDs) were between ±1 % and ±20 %. The method limits of quantification ranged from 5 to 25 ng L-1, the only exceptions being heroin (275 ng L-1) and morphine-3ß-glucuronide (250 ng L-1). Suppression/enhancement is comparable between the synthetic and the influent wastewater. The analytical method was applied to the OPs analysis in twenty-one influent samples collected from the treatment plants treating the wastewater of Valencia City (Spain). Twelve OPs were detected with total daily concentrations ranging from 1 ng L-1 to 2135 ng L-1. The widespread presence of these compounds in water suggests potential widespread exposure, highlighting the need for increased environmental awareness. Furthermore, the estimated daily intake results raise concerns about opioid use as a potential future health and social issue.

6.
J Hazard Mater ; 476: 135100, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38972200

RESUMO

This research proposes a simple and novel strategy for the green detection of antibiotics along with the reduction of microplastic and humic acid (HA) hazards. The entire process is based on a single-step solvent-sieving method to separate HA into insoluble (IHA) and soluble (SHA) components, subsequently recombining and designing the application according to the original characteristics of selected fractions in accordance with the zero-waste principle. IHA was applied as a dispersive solid phase extraction (DSPE) sorbent without chemical modification for the enrichment of trace MACs in complex biological matrices. The recovery of MACs was 74.06-100.84 % in the range of 2.5-1000 µg∙kg-1. Furthermore, SHA could be combined with biodegradable polyvinyl alcohol (PVA) to prepare multifunctional composite films. SHA endows the PVA film with favorable mechanical properties, excellent UV shielding as well as oxidation resistance performance. Compared with pure PVA, the tensile strength, toughness, antioxidant and UV-protection properties were increased to 157.3 Mpa, 258.6 MJ·m-3, 78.6 % and 60 % respectively. This study achieved a green and economically valuable utilization of all components of waste HA, introduced a novel approach for monitoring and controlling harmful substances and reducing white pollution. This has significant implications for promoting sustainable development and recovering valuable resources.

7.
J Hazard Mater ; 476: 135111, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38981231

RESUMO

Covalent organic frameworks (COFs) are attractive materials for sample pretreatment due to their tunable structures and functions. However, the precise recognition of contaminant in complex environmental matrices by COFs remains challenging owing to their insufficient specific active sites. Herein, we report Co2+ coordination-assisted molecularly imprinted flexible COF (MI-COF@Co2+) for selective recognition of ochratoxin A (OTA). The MI-COF@Co2+ was prepared via one-step polymerization of 3,3-dihydroxybenzidine, 2,4,6-tris(4-formylphenoxy)- 1,3,5-triazine, Co2+ and template. The flexible units endowed COFs with the self-adaptable ability to regulate the molecular conformation and coordinate with Co2+ to locate the imprinted cavities. The coordination interaction greatly improved the adsorption capacity and selectivity of MI-COF@Co2+ for OTA. The prepared MI-COF@Co2+ was used as solid phase extraction adsorbent for high-performance liquid chromatography determination of OTA with the detection limit of 0.03 ng mL-1 and the relative standard deviation of < 2.5 %. In addition, this method permitted interference-free determination of OTA in real samples with recovery from 89.5 % to 102.8 %. This work provides a simple way to improve the selectivity of COFs for the determination of hazardous compounds in complex environments.

8.
J Hazard Mater ; 476: 135112, 2024 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-38981234

RESUMO

In light of the significant risks that mycotoxins posed to public health and environmental safety, this research developed an adsorbent MIPs/Apt/AuNPs@ZIF-67 (MA-AZ) utilizing a dual-recognition approach combining molecularly imprinted polymers (MIPs) and aptamer (Apt). This innovative method enabled the effective and highly selective recognition and enrichment of ochratoxin A (OTA). ZIF-67 was utilized as a carrier with a substantial specific surface area, and gold nanoparticles (AuNPs) were loaded on its surface to fix the thiol-modified Apt on the surface of the carrier. Then, an initiator was used to initiate a polymerization reaction, and the generated MIPs coated Apt/AuNPs@ZIF-67, thereby synthesizing the MA-AZ with a "synergistic recognition" effect. The Apt significantly increased the number of recognition sites within the imprinted cavities, and MIPs played roles in identifying targets, fixing and protecting Apt. The combination of the both produced the effect of "1+1>2". The study on the adsorption performance of MA-AZ found that the adsorption capacity of MA-AZ could reach 65.1 mg/g, and the imprinted factor was 5.48. In addition, MA-AZ exhibited excellent stability, specificity, reusability and recovery rate. Thus, this study offers valuable insights for the recognition and enrichment of hazardous substances, and helps to promote the rapid development of safety detection.

9.
J Pharm Biomed Anal ; 249: 116336, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38981249

RESUMO

In this study, a new magnetic solid phase extraction based on magnetic composite modified with biochar obtained from pumpkin peel was developed for the enrichment and extraction of Naproxen in lake water, tablet and urine samples. The effects of main parameters such as pH, extraction time, amount of adsorbent and sample volume, which affect magnetic solid phase extraction, were investigated. Under optimal conditions, intraday and interday precision values for naproxen were below 5.9, with accuracy (relative error) better than 7.0 %. The detection limit and preliminary concentration factor were 12 ng/mL and 10, respectively. The method proposed here can be used for routine analysis of naproxen in lake water, urine and tablets.

10.
J Chromatogr A ; 1730: 465140, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38986401

RESUMO

In this work, a novel polyaniline-modified magnetic microporous organic network (MMON-PANI) composite was fabricated for effective magnetic solid phase extraction (MSPE) of five typical nonsteroidal anti-inflammatory drugs (NSAIDs) from animal-derived food samples before high performance liquid chromatography (HPLC) detection. The core-shell sea urchin shaped MMON-PANI integrates the merits of Fe3O4, MON, and PANI, exhibiting large specific surface area, rapid magnetic responsiveness, good stability, and multiple binding sites to NSAIDs. Convenient and effective extraction of trace NSAIDs from chicken, beef and pork samples is realized on MMON-PANI via the synergetic π-π, hydrogen bonding, hydrophobic, and electrostatic interactions. Under optimal conditions, the MMON-PANI-MSPE-HPLC-UV method exhibits wide linear ranges (0.2-1000 µg L-1), low limits of detection (0.07-1.7 µg L-1), good precisions (intraday and inter-day RSDs < 5.4 %, n = 3), large enrichment factors (98.6-99.9), and less adsorbent consumption (3 mg). The extraction mechanism and selectivity of MMON-PANI are also evaluated in detail. This work proves the incorporation of PANI onto MMON is an efficient way to promote NSAIDs enrichment and provides a new strategy to synthesize multifunctional MON-based composites in sample pretreatment.

11.
Food Chem X ; 23: 101558, 2024 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-38984290

RESUMO

Rapid analysis of multiple food allergens is required to confirm the appropriateness of food allergen labelling in processed foods. This study aimed to develop a rapid and reliable method to simultaneously detect trace amounts of seven food allergenic proteins (wheat, buckwheat, milk, egg, crustacean, peanut, and walnut) in processed foods using LC-MS/MS. Suspension-trapping (S-Trap) columns and on-line automated solid-phase extraction were used to improve the complex and time-consuming pretreatment process previously required for allergen analysis using LC-MS/MS. The developed method enabled the simultaneous detection of selected marker peptides for specific proteins derived from seven food ingredients in five types of incurred samples amended with trace amounts of allergenic proteins. The limit of detection values of the method for each protein were estimated to be <1 mg/kg. The developed analytical approach is considered an effective screening method for confirming food allergen labelling on a wide range of processed foods.

12.
Talanta ; 277: 126339, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38823321

RESUMO

Bisphenols and benzophenones are two typical kinds of endocrine-disrupting compounds (EDCs) that have been extensively detected in water environments, posing unanticipated risks to aquatic organisms and humans. It is urgent to develop efficient sample pretreatment methods for precise measurement of such EDCs. In this study, a magnetic and multi-shelled metal-organic framework derivative material has been prepared to extract and enrich trace bisphenols and benzophenones from water. Via a solvothermal reaction induced by sodium citrate followed by a carbonization treatment, a ZIF-67@ZIF-8 derived CoZn-magnetic hierarchical carbon (CoZn-MHC) material has been synthesized as a high-performance magnetic solid-phase extraction (MSPE) adsorbent. This adsorbent exhibited a good specific surface area (213.80 m2⋅g-1) and a saturation magnetization of 63.2 emu·g-1. After the optimization of several parameters (including adsorbent dosage, extraction time, pH, ionic strength, desorption solvent, and solvent volume), an efficient MSPE method for several EDCs (comprising bisphenols and benzophenones) was developed with a good linear range (R2 ≥ 0.990), a high sensitivity range (LODs: 0.793-5.37 ng⋅L-1), and good reusability (RSD ≤4.67 % in five consecutive tests). Furthermore, the material exhibited commendable resistance to matrix interference in natural water samples with the recovery rates of target compounds ranging from 74.8 % to 107 %. We envision that the preparation strategy of this functional metal-organic framework (MOF)-based adsorbent for EDCs may provide insights for relevant research in the future.

13.
Carbohydr Polym ; 339: 122257, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38823923

RESUMO

Traditional solid phase extraction (SPE) suffers from a lack of specific adsorption. To overcome this problem, a combination of adsorption method and molecular imprinting technology by polydopamine modification was proposed to realize specific recognition of target compounds in SPE, which is of great significance to improve the separation efficiency of SPE. Cellulose hydrogel beads were prepared by dual cross-linking curing method and modified with polydopamine to make them hydrophilic and biocompatible. Subsequently, cellulose hydrogel-based molecularly imprinted beads (MIBs) were synthesized by surface molecular imprinting technology and used as novel column fillers in SPE to achieve efficient adsorption (34.16 mg·g-1) with specific selectivity towards camptothecin (CPT) in 120 min. The simulation and NMR analysis revealed that recognition mechanism of MIBs involved hydrogen bond interactions and Van der Waals effect. The MIBs were successful used in separating CPT from Camptotheca acuminata fruits, exhibiting impressive adsorption capacity (1.19 mg·g-1) and efficient recovery of CPT (81.54 %). Thus, an environmentally friendly column filler for SPE was developed, offering a promising avenue for utilizing cellulose-based materials in the selective separation of natural products.


Assuntos
Camptotecina , Celulose , Hidrogéis , Impressão Molecular , Extração em Fase Sólida , Camptotecina/química , Camptotecina/isolamento & purificação , Celulose/química , Adsorção , Impressão Molecular/métodos , Hidrogéis/química , Extração em Fase Sólida/métodos , Camptotheca/química , Polímeros/química , Interações Hidrofóbicas e Hidrofílicas , Indóis/química , Frutas/química
14.
Artigo em Inglês | MEDLINE | ID: mdl-38880055

RESUMO

Grape and grape derived products contain many bioactive phenolics which have a variety of impacts on health. Following oral ingestion, the phenolic compounds and their metabolites may be detectable in human urine. However, developing a reliable method for the analysis of phenolic compounds in urine is challenging. In this work, we developed and validated a new high-throughput, sensitive and reproducible analytical method for the simultaneous analysis of 31 grape phenolic compounds and metabolites using Oasis PRiME HLB cleanup for sample preparation combined with ultra-performance liquid chromatography with triple quadrupole tandem mass spectrometry (UHPLC-QqQ-MS/MS). Using this new method, the accuracy achieved was 69.3 % ∼ 134.9 % (except for six compounds), and the recovery achieved was 52.4 % ∼ 134.7 % (except for two very polar compounds). For each of the 31 target analytes, the value of intra-day precision was less than 14.3 %. The value of inter-day precision was slightly higher than intra-day precision, with a range of 0.7 % ∼ 19.1 %. We report for the first time on the effect of gender and BMI on the accuracy and recovery of human urine samples, and results from analysis of variance (ANOVA), and principal component analysis (PCA) indicated there was no difference in the value of accuracy and recovery between different gender or BMI (>30) using our purposed cleanup and UHPLC-QqQ-MS/MS method. Overall, this newly developed method could serve as a powerful tool for analyzing grape phenolic compounds and metabolites in human urine samples.


Assuntos
Polifenóis , Espectrometria de Massas em Tandem , Vitis , Humanos , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/métodos , Vitis/química , Polifenóis/urina , Reprodutibilidade dos Testes , Masculino , Feminino , Modelos Lineares , Limite de Detecção , Adulto , Ensaios de Triagem em Larga Escala/métodos
15.
Food Chem ; 458: 140215, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38944928

RESUMO

A magnetic adsorbent was synthesized by coupling magnetic nanoparticles, UiO-66-NH2 and 1-butyl-trimethylimidazole bromide ([BMIM][Br]) to chitosan (CS)-based composite conveniently. A series of modern characterizations were employed to assess its properties. The results showed that UiO-66-NH2 was uniformly distributed within the composite via in-situ growth, which can enhance the porosity obviously. The introduction of various ligands enables the composite to exhibit excellent extraction performance for four aflatoxins (AFs) through multiple interactions. The adsorption mechanism was elucidated and the main factors affecting extraction efficiency were evaluated. Under optimal conditions, the limits of detection (LODs) ranged from 0.08 to 0.56 µg/kg. The established method was successfully utilized to determine AFs from cereal samples (rice, glutinous rice, wheat, soybean, paddy, and corn) with satisfactory recovery of 77% âˆ¼ 119% with relative standard deviations (RSDs) of 1.0% âˆ¼ 11.7% (n = 5). The adsorbent demonstrated sufficient robustness for repeated use at least six times without obvious damage of extraction property.

16.
Molecules ; 29(12)2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38930920

RESUMO

A promising method was established for the determination of nine halobenzoquinones (HBQs) in potable water by membrane solid-phase extraction (MSPE) pretreatment and the liquid chromatography-mass spectrometry (LC-MS) method. A 500 mL water sample was taken for enrichment by the SDB-RPS membrane, which was previously activated by methanol and ultrapure water. The sample was eluted with methanol and re-dissolved with the initial mobile phase after nitrogen blowing. Then, it was detected in negative ion mode using the working curve, and HBQs were quantified by the external standard method. The linearity was satisfactory in the concentration range of 4-1000 ng/L, with correlation coefficients of 0.9963~0.9994. The recoveries were 73.5~126.6% at three spiked levels, with relative standard deviations (RSDs) of 6.8~15.5%. The limits of detection (LOD, S/N = 3) values were 0.1~0.7 ng/L. The results demonstrate that the MSPE-LC-MS method is reliable, rapid, and sensitive for the simultaneous analysis of nine HBPs in potable water.


Assuntos
Benzoquinonas , Água Potável , Extração em Fase Sólida , Extração em Fase Sólida/métodos , Cromatografia Líquida/métodos , Benzoquinonas/química , Benzoquinonas/análise , Água Potável/análise , Água Potável/química , Espectrometria de Massas/métodos , Limite de Detecção , Poluentes Químicos da Água/análise , Espectrometria de Massa com Cromatografia Líquida
17.
Molecules ; 29(12)2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38930985

RESUMO

The abuse and irrational use of tetracyclines (TCs) in human medicine and animal husbandry has become a serious concern, affecting the ecological environment and human health. The aim of this study was to develop a sensitive and selective method using fully automatic solid-phase extraction coupled with ultra-performance liquid chromatography-tandem mass spectrometry for the determination of twelve TCs in water. Four isotope-labeled internal standards for TCs were used to correct matrix effects. Several parameters affecting extraction efficiency were systematically optimized, and the optimum experimental conditions found were 1.0 L water sample with 0.5 g/L Na2EDTA (pH 3.0) extracted and enriched by CNW HLB cartridge and eluted by 4 mL of acetone:methanol (v/v, 1:1). The enrichment factors were up to 798-1059 but only requiring about 60 min per six samples. Under the optimized conditions, the linearity of the method ranged from 0.2 to 100 µg/L for 12 TCs, the detection limits were as low as 0.01-0.15 ng/L, and the recoveries were in the range of 70%-118%, with relative standard deviations less than 15%. The developed method can be successfully utilized for the determination of 12 TCs in pure water, tap water, river water, and mariculture seawater. In summary, three and six TCs were detected in river water and mariculture seawater, respectively, with total concentrations of 0.074-0.520 ng/L (mean 0.248 ng/L) and 0.792-58.369 ng/L (12.629 ng/L), respectively. Tetracycline (TC) and oxytetracycline (OTC) were the dominant TCs in river water, while doxytetracycline (DXC) and OTC were dominant in mariculture seawater.


Assuntos
Água Potável , Extração em Fase Sólida , Espectrometria de Massas em Tandem , Tetraciclinas , Poluentes Químicos da Água , Espectrometria de Massas em Tandem/métodos , Extração em Fase Sólida/métodos , Tetraciclinas/análise , Poluentes Químicos da Água/análise , Água Potável/análise , Água Potável/química , Cromatografia Líquida de Alta Pressão/métodos , Limite de Detecção
18.
J Chromatogr A ; 1730: 465086, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38941797

RESUMO

Polycyclic aromatic hydrocarbons are air pollutants that affect the human health and the environment, and their accurate determination in outdoor and indoor environments is important. This study presents a methodology for sampling and analysis of semi-volatile compounds in ambient air with emphasis on the polycyclic aromatic hydrocarbons, collected with low-volume pumps (4.8 m3) in unconditioned solid phase extraction cartridges (Isolute ENV+). Sampling in SPE cartridges with low-volume pumps allows the collection of both gas and particulate phase compounds in indoor as well as outdoor environments, and reduces the number of extraction steps required as well as the solvent volume used for extraction. Analysis of the 16 US-EPA priority PAHs after extraction was conducted by GC-MS/MS with recoveries of the PAHs 40-118 %. No breakthrough was detected during sampling. Moreover, the methodology includes storage test to assess the conservation of PAHs in the SPE cartridges in heat-sealable Kapac bags; simulating transport from sampling sites to laboratory, and storage under room, cold and frozen conditions at different time-intervals, up to 3 months after sampling. The results showed that concentration levels remained constant across various storage time intervals and temperatures, with naphthalene and acenaphthylene being the only exceptions, showing high blank levels for the first and losses at room temperature for the later. The method quantification limits, including sampling, storage and GC-MS/MS analysis ranged from 2000 pg m-3 for naphthalene and 300 pg m-3 for phenanthrene to less than 20.0 pg m-3 for higher molecular and less volatile PAHs, such as benzo[a]pyrene (LOQ = 8.0 pg m-3). The feasibility of the method was tested by sampling indoors under urban background air conditions, showing individual PAH concentrations 4 to 10 times higher than their method quantification limits.

19.
Food Chem ; 457: 140192, 2024 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-38941906

RESUMO

This study introduced an innovative magnetic effervescence-assisted microextraction method, streamlining the preparation of effervescent tablets through a one-pot method that blends a CO2 donor (Na2CO3) and an H+ donor (NaH2PO4) with bare magnetic particles (Fe3O4) and an adsorbent (hydroxylated multi-walled carbon nanotubes), followed by pressing. During the extraction process, the bare magnetic particles and adsorbent undergo in-situ self-assembly to create a magnetic adsorbent. The effervescence generates bubbles that enhance effective extraction and magnetism facilitates the easy separation of the magnetic adsorbent from the sample solution, completing the process within 4 min. Applied to organochlorine pesticide analysis in fruit juices and herbal extracts, the method exhibits excellent linearity (R2 > 0.993), sensitivity (detection limits: 0.010-0.125 ng/mL), accuracy (recoveries: 85.8-99.9%), and precision (RSDs < 9.7%) with GC-ECD. Overall, this approach stands out for its simplicity, cost-effectiveness, and suitability for on-site analysis, owing to its operational ease and independence from specialized equipment.

20.
Food Chem ; 456: 139294, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38914034

RESUMO

The study aimed to develop a rapid and sensitive colorimetric platform based on the Emerson reaction to visualize and determine total aflatoxins (AFs) in peanut oil. This method offers the advantage of fast screening for AFs (AFB1, AFB2, AFG1, and AFG2), eliminating the need for specific antibodies. The proposed approach combined colorimetric detection with magnetic dummy imprinted solid-phase extraction and purification, enhancing sensitivity and selectivity. The oxidizer aided the colorless AFs in reacting with 4-aminoantipyrine, producing green condensates. Thus, a dual-mode approach was developed for AFs detection, employing both UV-vis colorimetric and smartphone-based colorimetry. Both methods showed a good linear relationship with the concentration of AFs. Notably, the smartphone-based method demonstrated a detection range of 0.5-57 µg/kg, with a detection limit as low as 0.21 µg/kg. The suggested colorimetric methods present a promising potential for onsite detection and fast screening of AFs in actual samples.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...