Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.087
Filtrar
1.
World J Gastrointest Surg ; 16(6): 1527-1536, 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38983348

RESUMO

BACKGROUND: Natural orifice specimen extraction surgery (NOSES) has emerged as a promising alternative compared to conventional laparoscopic-assisted total gastrectomy (LATG) for treating gastric cancer (GC). However, evidence regarding the efficacy and safety of NOSES for GC surgery is limited. This study aimed to compare the safety and feasibility, in addition to postoperative complications of NOSES and LATG. AIM: To discuss the postoperative effects of two different surgical methods in patients with GC. METHODS: Dual circular staplers were used in Roux-en-Y digestive tract reconstruction for transvaginal specimen extraction LATG, and its outcomes were compared with LATG in a cohort of 51 GC patients with tumor size ≤ 5 cm. The study was conducted from May 2018 to September 2020, and patients were categorized into the NOSES group (n = 22) and LATG group (n = 29). Perioperative parameters were compared and analyzed, including patient and tumor characteristics, postoperative outcomes, and anastomosis-related complications, postoperative hospital stay, the length of abdominal incision, difference in tumor type, postoperative complications, and postoperative survival. RESULTS: Postoperative exhaust time, operation duration, mean postoperative hospital stay, length of abdominal incision, number of specific staplers used, and Brief Illness Perception Questionnaire score were significant in both groups (P < 0.01). In the NOSES group, the postoperative time to first flatus, mean postoperative hospital stay, and length of abdominal incision were significantly shorter than those in the LATG group. Patients in the NOSES group had faster postoperative recovery, and achieved abdominal minimally invasive incision that met aesthetic requirements. There were no significant differences in gender, age, tumor type, postoperative complications, and postoperative survival between the two groups. CONCLUSION: The application of dual circular staplers in Roux-en-Y digestive tract reconstruction combined with NOSES gastrectomy is safe and convenient. This approach offers better short-term outcomes compared to LATG, while long-term survival rates are comparable to those of conventional laparoscopic surgery.

2.
Sex Transm Infect ; 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38964838

RESUMO

OBJECTIVES: Sexually transmitted infections (STIs) have markedly increased over the last decade in Spain, calling for prevention and control innovative approaches. While there is evidence indicating the effectiveness of self-sampling for STI diagnosis, no kits for this purpose have been authorised in Spain. METHODS: A prospective single-blind cross-sectional study carried out between November and December 2022 in an STI clinic in Madrid, Spain, to determine the validity, feasibility and acceptability of self-sampling kits used by non-healthcare professionals from vagina, pharynx, rectum and urethra to diagnose Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG). Self-samples were compared with samples collected by healthcare professional (HC samples) and analysed by PCR. Frequency of CT and NG diagnosis by sample type was compared using McNemar's test for paired data. Sensitivity and specificity of self-samples for CT and NG diagnosis were also calculated. RESULTS: 306 self-samples from 51 participants were analysed. 80% were men with median age of 33 (IQR: 28-38) years. Self-samples and HC samples showed no significant statistical differences in CT and NG diagnosis. Self-samples had a sensitivity of 81% for CT and 93% for NG, with a specificity of 97% for CT and 95% for NG. More than 90% of participants had no difficulty understanding the kit instructions and 71% expressed high levels of satisfaction with the self-sampling kit. CONCLUSION: Self-sampling kits for CT and NG diagnosis can be safely and effectively used by non-healthcare professionals in Spain. National strategies for STI prevention and control should prioritise self-sampling strategies.

3.
Semin Diagn Pathol ; 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38965021

RESUMO

Achieving clear resection margins at the time of lumpectomy is essential for optimal patient outcomes. Margin status is traditionally determined by pathologic evaluation of the specimen and often is difficult or impossible for the surgeon to definitively know at the time of surgery, resulting in the need for re-operation to obtain clear surgical margins. Numerous techniques have been investigated to enhance the accuracy of intraoperative margin and are reviewed in this manuscript.

4.
Int J Clin Oncol ; 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38977538

RESUMO

PURPOSE: To measure the micro-foci distance away from gross tumor and to provide reference to create the clinical target volume (CTV) margin for boost radiotherapy in rectal adenocarcinoma. METHODS: Twenty-eight rectal cancer surgical specimens of only total mesorectal excision were collected. The pathological specimens were retrospectively measured, and the nearest distance between the tumor micro-foci and gross tumor was microscopically measured. The "in vivo-in vitro" retraction factor was calculated as the ratio of the deepest thickness laterally and the vertical height superior/inferiorly of the rectal tumor measured in MRI and those measured in immediate pathological specimens. The retraction factor during pathological specimen processing was calculated as the distance ratio before and after dehydration in the lateral, superior, and inferior sides by the "knot marking method." The distances of tumor micro-foci were individually corrected with these two retraction factors. RESULTS: The mean "in vivo-in vitro" tumor retraction factors were 0.913 peripherally and 0.920 superior/inferiorly. The mean tumor specimen processing retraction factors were 0.804 peripherally, 0.815 inferiorly, and 0.789 superiorly. Of 28 patients, 14 cases (50.0%) had 24 lateral micro-foci, 8 cases (28.6%) had 13 inferior micro-foci, and 7 cases (25.0%) had 19 superior micro-foci. The 95th percentiles of the micro-foci distance for 28 patients were 6.44 mm (peripheral), 5.54 mm (inferior), and 5.42 mm (superior) after retraction correction. CONCLUSION: The micro-foci distances of 95% of rectal adenocarcinoma patients examined were within 6.44 mm peripherally, 5.54 mm inferiorly, and 5.42 mm superiorly. These findings provide reference to set the boost radiotherapy CTV margin for rectal cancer.

5.
Cells ; 13(11)2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38891057

RESUMO

The identification of anticancer therapies using next-generation sequencing (NGS) is necessary for the treatment of cholangiocarcinoma. NGS can be easily performed when cell blocks (CB) are obtained from bile stored overnight. We compared NGS results of paired CB and surgically resected specimens (SRS) from the same cholangiocarcinoma cases. Of the prospectively collected 64 bile CBs from 2018 to 2023, NGS was performed for three cases of cholangiocarcinoma that could be compared with the SRS results. The median numbers of DNA and RNA reads were 95,077,806 [CB] vs. 93,161,788 [SRS] and 22,101,328 [CB] vs. 24,806,180 [SRS], respectively. We evaluated 588 genes and found that almost all genetic alterations were attributed to single-nucleotide variants, insertions/deletions, and multi-nucleotide variants. The coverage rate of variants in SRS by those found in CB was 97.9-99.2%, and the coverage rate of SRS genes by CB genes was 99.6-99.7%. The NGS results of CB fully covered the variants and genetic alterations observed in paired SRS samples. As bile CB is easy to prepare in general hospitals, our results suggest the potential use of bile CB as a novel method for NGS-based evaluation of cholangiocarcinoma.


Assuntos
Bile , Colangiocarcinoma , Sequenciamento de Nucleotídeos em Larga Escala , Colangiocarcinoma/genética , Colangiocarcinoma/patologia , Humanos , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Bile/metabolismo , Masculino , Pessoa de Meia-Idade , Feminino , Neoplasias dos Ductos Biliares/genética , Neoplasias dos Ductos Biliares/patologia , Idoso , Mutação/genética
6.
Stud Hist Philos Sci ; 106: 70-85, 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38906073

RESUMO

Chronostratigraphy is the subfield of geology that studies the relative age of rock strata and that aims at producing a hierarchical classification of (global) divisions of the historical time-rock record. The 'golden spike' or 'GSSP' approach is the cornerstone of contemporary chronostratigraphic methodology. It is also perplexing. Chronostratigraphers define each global time-rock boundary extremely locally, often by driving a gold-colored pin into an exposed rock section at a particular level. Moreover, they usually avoid rock sections that show any meaningful sign of paleontological disruption or geological discontinuity: the less obvious the boundary, the better. It has been argued that we can make sense of this practice of marking boundaries by comparing the status and function of golden spikes to that of other concrete, particular reference standards from other sciences: holotypes from biological taxonomy and measurement prototypes from the metrology of weight and measures. Alisa Bokulich (2020b) has argued that these 'scientific types' are in an important sense one of a kind: they have a common status and function. I will argue that this picture of high-level conceptual unity is mistaken and fails to consider the diversity of aims and purposes of standardization and classification across the sciences. I develop an alternative, disunified account of scientific types that shows how differences in ontological attitudes and epistemic aims inform scientists' choices between different kinds of scientific types. This perspective on scientific types helps to make sense of an intriguing mid-twentieth-century debate among chronostratigraphers about the very nature of their enterprise. Should chronostratigraphers conventionally make boundaries by designating golden spikes, or should they attempt to mark pre-existing 'natural' boundaries with the help of a different kind of scientific type?

8.
Surg Endosc ; 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38914889

RESUMO

BACKGROUND: Despite the global increase in the adoption of robotic natural orifice specimen extraction surgery (R-NOSES), its advantages over robotic transabdominal specimen extraction surgery (R-TSES) for treating early-stage rectal cancer remain debated. There is scant nationwide, multicenter studies comparing the surgical quality and short-term outcomes between R-NOSES and R-TSES for this condition. OBJECTIVE: This retrospective cohort study was conducted nationally across multiple centers to compare the surgical quality and short-term outcomes between R-NOSES and R-TSES in early-stage rectal cancer. DESIGN: Multicenter retrospective cohort trial. SETTING: Eight experienced surgeons from 8 high-volume Chinese colorectal cancer treatment centers. PATIENTS: The study included 1086 patients who underwent R-NOSES or R-TSES from October 2015 to November 2023 at the 8 centers. Inclusion criteria were: (1) histologically confirmed rectal adenocarcinoma; (2) robotic total mesorectal excision; (3) postoperative pathological staging of TisN0M0 or T1-2N0M0; (4) availability of complete surgical and postoperative follow-up data. Patients were matched 1:1 in the R-NOSES and R-TSES groups using the propensity score matching (PSM) technique. RESULTS: After PSM, 318 matched pairs with well-balanced patient characteristics were identified. The operation time for the R-NOSES group was significantly longer than that for the R-TSES group [140 min (125-170 min) vs. 140 min (120-160 min), P = 0.032]. Conversely, the times to first flatus and initial oral intake in the R-NOSES group were significantly shorter than those in the R-TSES group [48 h (41-56 h) vs. 48 h (44-62 h), P = 0.049 and 77 h (72-94 h) vs. 82 h (72-96 h), P = 0.008], respectively. Additionally, the length of postoperative hospital stay was shorter in the R-NOSES group compared with the R-TSES group [7 day (7-9 day) vs. 8 day (7-9 day), P = 0.005]. The overall postoperative complication rates were similar between the groups (10.7% in the R-NOSES group vs. 11.9% in the R-TSES group, P = 0.617). However, the R-NOSES group had a lower incidence of wound complications compared to the R-TSES group (0.0% vs. 2.2%, P = 0.015). Regarding surgical stress response, the R-NOSES group showed superior outcomes. Additionally, patients in the R-NOSES group required fewer additional analgesics on postoperative days 1, 3, and 5 and reported lower pain scores compared to the R-TSES group. The body image scale (BIS) and cosmetic scale (CS) scores were also significantly higher in the R-NOSES group. Furthermore, the R-NOSES group demonstrated significantly better outcomes in functional dimensions such as physical, role, emotional, social, and cognitive functioning, and in symptoms like fatigue and pain, when compared to the R-TSES group. LIMITATIONS: It is imperative to ensure the safe and standardized implementation of R-NOSES through the establishment of a uniform training protocol. CONCLUSIONS: These results affirm that R-NOSES is a safe and effective treatment for early-stage rectal cancer when meticulously executed by skilled surgeons.

9.
Toxicol Lett ; 398: 118-126, 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38925422

RESUMO

For the investigation of diseases and other harmful environmental influences (e.g., chemicals) epidemiological studies rely on high quality human samples, among others. Collecting samples and data in the field can pose an enormous challenge to the study team with regard to health protection and occupational safety, especially in the context of a pandemic where there was great uncertainty about the biological risks associated with SARS-CoV-2. The German Environmental Specimen Bank (German ESB) is a key element of environmental and human biomonitoring in Germany with the aim to document and assess trends of human and environmental exposure to chemicals over time and to provide scientific data for policy decision makers. Starting with a pilot study in 1978 human samples are now collected at four sampling locations annually, while sampling is carried out with a highly standardized mobile laboratory since 2013. Due to the corona pandemic 3 of 4 ESB sampling campaigns had to be cancelled in 2020. However, a continuous sampling is crucial to generate current policy relevant data on chemical exposure. Hence, a protection and hygiene concept has been developed including COVID-19 testing with the goal to protect the health of participants and employees during sampling and to meet legal requirements, while sustaining the standardized procedures of sampling and sample preparation. The concept is based on a flexible approach to allow adjustments to changing government regulations and recommendations in the course of the pandemic. By implementing this concept, all samplings were successfully carried out in 2021 & 2022, with the pandemic still ongoing. This paper provides an example of good practice and valuable insights in how to collect human samples during a pandemic.

10.
Pan Afr Med J ; 47: 112, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38828425

RESUMO

Introduction: laboratory errors mostly emerge from the pre-analytical phase, mainly those related to collection, handling, transportation, and storage of diagnostic specimens. Specimen rejection due to improper sample collection, may lead to poor patient outcomes, such as incorrect diagnosis, inappropriate treatment, and death. This study aimed to assess the specimen rejection rate and associated factors among referred specimens at Debre Markos Referral Hospital. Methods: a prospective cross-sectional study design was applied from January 2020 to April 2020 to investigate specimen rejection rate and associated factors among referred specimens. The study population was all laboratory specimens referred for viral load, CD4 count, gene expert, and early infant diagnosis to the Debre Markos Referral Hospital laboratory. The statistical analysis was done with Statistical Package for Social Sciences version 20.0 software. Results: of the total of 2750 specimens submitted to the laboratory from January 2020 to April 2020, 37 (1.34%) specimens were rejected due to different reasons like insufficient volume, hemolysis, and an inappropriate specimen container. Specimen collector training status and experience had a significant association with the specimen rejection rate. Conclusion: the results of our study show that the specimen rejection rate among referred specimens was high, indicating that more interventions are required to decrease the specimen rejection rate.


Assuntos
Manejo de Espécimes , Humanos , Estudos Transversais , Estudos Prospectivos , Etiópia , Manejo de Espécimes/métodos , Encaminhamento e Consulta/estatística & dados numéricos , Erros de Diagnóstico/estatística & dados numéricos , Lactente , Carga Viral , Masculino , Feminino , Contagem de Linfócito CD4 , Laboratórios Hospitalares/normas
11.
Microsc Microanal ; 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38833315

RESUMO

Cryogenic atom probe tomography (cryo-APT) is being developed to enable nanoscale compositional analyses of frozen liquids. Yet, the availability of readily available substrates that allow for the fixation of liquids while providing sufficient strength to their interface is still an issue. Here, we propose the use of 1-2-µm-thick binary alloy film of gold-silver sputtered onto flat silicon, with sufficient adhesion without an additional layer. Through chemical dealloying, we successfully fabricate a nanoporous substrate, with an open-pore structure, which is mounted on a microarray of Si posts by lift-out in the focused-ion beam system, allowing for cryogenic fixation of liquids. We present cryo-APT results obtained after cryogenic sharpening, vacuum cryo-transfer, and analysis of pure water on the top and inside the nanoporous film. We demonstrate that this new substrate has the requisite characteristics for facilitating cryo-APT of frozen liquids, with a relatively lower volume of precious metals. This complete workflow represents an improved approach for frozen liquid analysis, from preparation of the films to the successful fixation of the liquid in the porous network, to cryo-APT.

12.
Langenbecks Arch Surg ; 409(1): 172, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38829526

RESUMO

AIM: Natural orifice specimen extraction (NOSE) is an alternative to conventional transabdominal retrieval. We aimed to compare outcomes following transvaginal specimen extraction (TVSE) and transabdominal specimen extraction (TASE) in minimally invasive abdominal surgery. METHODS: An electronic database search of PubMed, Embase and CENTRAL was performed from inception until March 2023. Comparative studies evaluating TVSE versus TASE in adult female patients were included. Studies involving transanal NOSE, endoluminal surgery, or TVSE with concomitant hysterectomy were excluded. Weighted mean differences (WMD) and odds ratio were estimated for continuous and dichotomous outcomes respectively. Primary outcomes were postoperative day 1 (POD1) pain and length of stay (LOS). Secondary outcomes were operative time, rescue analgesia, morbidity, and cosmesis. A review of sexual, oncological, and technical outcomes was performed. RESULTS: Thirteen studies (2 randomised trials, 11 retrospective cohort studies), involving 1094 patients (TASE 583, TVSE 511), were included in the analysis. Seven studies involved colorectal disease and six assessed gynaecological conditions. TVSE resulted in significantly decreased POD1 pain (WMD 1.08, 95% CI: 0.49, 1.68) and shorter LOS (WMD 1.18 days, 95% CI: 0.14, 2.22), compared to TASE. Operative time was similar between both groups, with fewer patients requiring postoperative rescue analgesia with TVSE. Overall morbidity rates, as well as both wound-related and non-wound related complication rates were better with TVSE, while anastomotic morbidity rates were comparable. Cosmetic scores were higher with TVSE. TVSE did not result in worse sexual or oncological outcomes. CONCLUSION: TVSE may be feasible and beneficial compared to TASE when performed by proficient laparoscopic operators, using appropriate selection criteria. Continued evaluation with prospective studies is warranted.


Assuntos
Procedimentos Cirúrgicos Minimamente Invasivos , Vagina , Humanos , Feminino , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Vagina/cirurgia , Cirurgia Endoscópica por Orifício Natural/métodos , Cirurgia Endoscópica por Orifício Natural/efeitos adversos , Tempo de Internação , Duração da Cirurgia
13.
Heliyon ; 10(11): e31736, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38845923

RESUMO

Background: The preanalytical phase encompasses the time between the clinician's test order to the sample being ready for analysis. Of all errors during the laboratory diagnostic process,70 % appeared in the pre-analytical phase. In clinical laboratories, it is crucial to ensure proper specimen collection and handling, which is essential to guarantee quality assessment, monitoring process standardization, improving performance, and ensuring patient safety. Despite this importance, no study has been conducted in the study area to investigate the rate and reasons for human immunodeficiency virus viral load sample rejection. Objective: To determine the rate of human immunodeficiency virus viral load sample rejection (number of preanalytical errors) documented during the preanalytical phase and articulate possible causes for specimen rejection. Material and methods: A retrospective study was conducted at Debre Tabor Comprehensive Specialized Hospital from January 1st to January 31, 2023. During the study period, 5950 samples were extracted from the human immunodeficiency virus viral load laboratory sample tracking log books, which were sent to the hospital for viral load testing between August 2021 to November 2022. The collected data were cleaned and entered into EPI data version 4.6 before transferred it to STATA version 14.0 for analysis. Descriptive statistics such as frequencies, percentages, and cross-tabulations were used to summarize the findings. Results: The study found that improper sample handling was common during the preanalytical phase. According to the current study, 3.6 % of the sample was rejected at pre analytical stage. The most common reasons for specimen rejection were using inappropriate containers (64.0 %) uncentrifuged specimens (20.4 %); hemolyzed specimens (7.0 %); insufficient specimen volume (6.2 %); clotted specimens (1.9 %); and specimen labeling problems (0.5 %). Conclusion: This study found that the most common preanalytical error was using an inappropriate sample collection container, followed by uncentrifuged samples, Therefore, it is recommended that mentorship programs be developed to educate staff on the preanalytical phase of laboratory testing, specifically on sample collection, storage, and transportation for HIV viral load testing. Additionally, the quality management system of laboratory processes should be strengthened to ensure accuracy and minimize errors.

14.
Gynecol Oncol Rep ; 54: 101421, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38881560

RESUMO

Vaginal self collection (SC) is safe and effective for human papillomavirus (HPV) testing and can increase cervical cancer screening coverage for underserved women. To better understand the impact of SC methodology on HPV test outcomes, empirical testing was conducted using different swab collection workflows. Deposition of the collection swab into resuspension buffer resulted in a 2.4-cycle reduction in threshold detection of human beta-hemoglobin during PCR when compared to "swirl-and-toss". In addition, reducing the swab resuspension volume from 10 mL to 3 mL resulted in a 2.6-cycle reduction in threshold detection of human beta-globin. A systematic literature search (01/01/2020 to 08/02/2023) of Ovid Medline and Embase, followed by data extraction and analysis, was conducted to further assess the impact of resuspension volume on performance following SC. HPV test performance for SC, relative to clinician collection (CC), was calculated for detection of cervical pre-cancer. Data were stratified by the resuspension volume ratio of SC to CC being either ≥ 1.0 or < 1.0. SC with a volume ratio of ≥ 1.0 and < 1.0 had a relative ≥ CIN2 sensitivity of 92.0 % (95 % CI: 88.0, 96.0) and 97.0 % (95 % CI: 94.0, 100), respectively. Taken together, these results suggest that SC conditions can be modified to optimize sample recovery and performance, as part of cervical cancer screening.

15.
Thorac Cancer ; 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38898747

RESUMO

BACKGROUND: The AmoyDx Pan lung cancer PCR panel (AmoyDx PLC panel) has been approved as a companion diagnostic tool for multiple anticancer agents in patients with non-small cell lung cancer (NSCLC). However, the suitability of cytology specimens as samples for the AmoyDx PLC panel remains unclear. We evaluated the performance of frozen cell pellets from cytology specimens (FCPs) in the Amoy 9-in-1 assay, a preapproval assay of the AmoyDx PLC panel. METHODS: We retrospectively collected data of NSCLC patients enrolled in LC-SCRUM-Asia from the Shizuoka Cancer Center between September 2019 and May 2021. RESULTS: A total of 49 cases submitted FCPs for evaluation of oncogenic driver alterations and were assessed using Amoy 9-in-1 and next-generation sequencing (NGS) assays. The success rates of DNA and RNA analyses using the Amoy 9-in-1 were both 100%, compared with 86% and 45%, respectively, using NGS assays. Oncogenic driver alterations were detected in 27 (55%) and 23 (47%) patients using Amoy 9-in-1 and NGS, respectively. No inconsistent results were observed among 19 cases in which both assays showed successful detection. In the remaining 30 cases, 10 had inconsistent results: nine oncogenic driver alterations (3 MET, 2 ALK, 2 ROS1, and 2 KRAS) were detectable only in Amoy 9-in-1, and one epidermal growth factor receptor (EGFR) mutation was detectable only in NGS. CONCLUSION: FCPs can be successfully used in the AmoyDx PLC panel, with higher success rate compared with the NGS assay. The AmoyDx PLC panel may be an option in cases when insufficient tissue sample is available for the NGS assay.

16.
Artigo em Inglês | MEDLINE | ID: mdl-38935214

RESUMO

BACKGROUND: In JCOG0306 trial, a phase II study to examine the efficacy of neoadjuvant chemotherapy followed by radiation therapy (NAC-RT) to primary breast cancer, pathological complete response (pCR) was evaluated from specimens of the representative cross-section including the tumor center that had been accurately marked [representative specimen (RS) method]. In this ancillary study, we examined if the RS method was comparable to the conventional total specimen (TS) method, which is widely employed in Japan, to identify the pCR group showing excellent prognosis. METHODS: We obtained long-term follow-up data of 103 patients enrolled in JCOG0306 trial. As histological therapeutic effect, pCR (ypT0 and ypT0/is) and quasi-pCR [QpCR, ypT0/is plus Grade 2b (only a few remaining invasive cancer cells)] were evaluated with RS and TS methods. Concordance of pCR between these two methods and associations of the pCR with prognosis were examined. RESULTS: ypT0, ypT0/is, and QpCR were observed in 28 (27.2%), 39 (37.9%), and 45 (43.7%) patients with RS method, whereas these were 20 (19.4%), 25 (24.3%) and 40 (38.9%) with TS method, respectively. Between RS and TS methods, concordance proportions of ypT0 and ypTis were 92.2% and 86.4%, respectively. Risk of recurrence of ypT0/is group was lower than that of non-ypT0/is group (HR 0.408, 95% CI [0.175-0.946], P = 0.037) and risk of death of ypT0/is group was lower than that of non-ypT0/is group (HR 0.251, 95% CI [0.073-0.857], P = 0.027). The ypT0 and ypT0/is groups with RS method showed excellent prognosis similarly with those with TS method, and RS method was able to differentiate the OS and RFS between pCR and non-pCR than TS method significantly even if pCR was classified ypT0 or ypT0/is. With TS method, QpCR criteria stratified patients into the better and worse prognosis groupsmore clearly than pCR criteria of ypT0 or ypT0/is. CONCLUSIONS: RS method was comparable to TS method for the evaluation of pCR in the patients who received NAC-RT to primary breast cancer provided the tumor center was accurately marked. As pCR criteria with RS method, ypT0/is appeared more appropriate than ypT0.

17.
Diagnostics (Basel) ; 14(12)2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38928623

RESUMO

There is a significant need to develop new environmentally friendly, extraction-free sample collection mediums that can effectively preserve and protect genetic material for point-of-care and/or self-collection, home-collection, and mail-back testing. Systematic evolution of ligands by exponential enrichment (SELEX) was used to create anti-ribonuclease (RNase) deoxyribonucleic acid (DNA) aptamers against purified RNase A conjugated to paramagnetic carboxylated beads. Following eight rounds of SELEX carried out under various stringency conditions, e.g., selection using Xtract-Free™ (XF) specimen collection medium and elevated ambient temperature of 28 °C, a panel of five aptamers was chosen following bioinformatic analysis using next-generation sequencing. The efficacy of aptamer inactivation of RNase was assessed by monitoring ribonucleic acid (RNA) integrity via fluorometric and real-time RT-PCR analysis. Inclusion of aptamers in reaction incubations resulted in an 8800- to 11,200-fold reduction in RNase activity, i.e., digestion of viral RNA compared to control. Thus, anti-RNase aptamers integrated into XF collection medium as well as other commercial reagents and kits have great potential for ensuring quality intact RNA for subsequent genomic analyses.

18.
Diagnostics (Basel) ; 14(12)2024 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-38928636

RESUMO

The present study focuses on establishing the quality assurance of laboratories for recent infections (RTRI) in Thailand. We developed a cold-chain independent method, using fully characterized plasma obtained from the Thai Red Cross Society, and prepared as dried tube specimens (DTS). Twenty microliters of HIV-seronegative, recent, and long-term infected samples were aliquoted into individual tubes and dried at room temperature, 20-30 degrees Celsius, in a biosafety cabinet overnight to ensure optimal preservation. The DTS external quality control and external quality assessment were tested for homogeneity and stability following the ISO/Guide 35 guidelines. The DTS panels were distributed to 48 sites (FY 2022) and 27 sites (FY 2023) across 14 and 9 provinces, respectively, in Thailand. The results from participating laboratories were collected and evaluated for performance. The results were scored, and acceptable performance criteria were defined as the proportion of panels correctly tested, which was set at 100%. The satisfactory performance ranged from 96% to 100% and was not significantly different among the 13 health regions. The developed and implemented DTS panels can be used to monitor the quality of RTRI testing in Thailand.

19.
Materials (Basel) ; 17(12)2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38930303

RESUMO

The application of advanced high-strength steel grades (AHSS) in different kinds of industry is connected to more than their attractive mechanical properties. The present paper focuses on improving the welding Docol 1300M steel to reach an acceptable microstructure and mechanical parameters. It was decided to manufacture joints with different welding parameters using different filler materials. The electrode wires were varied to increase the carbon content in the weld, and nitrogen was added to the argon shielding mixture to obtain non-metallic inclusions that strengthen the fusion zone. Specimens of joints welded with the gas metal arc welding (GMAW) process for non-destructive and destructive tests were examined. Tensile and bending tests as well as microscopic inspections using a light (LM) and scanning electron microscope (SEM) were also conducted. The results from the fatigue test confirmed the validity of the proposed welding process for the Docol 1300M joint. The collected data enabled the following conclusion: The article's novelty is represented by the use of shielding gas mixtures containing argon and nitrogen in the GMAW welding process of AHSS steel to create titanium non-metallic inclusions, which will translate into better performance properties of the entire joint.

20.
Cancer Rep (Hoboken) ; 7(5): e2003, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38703000

RESUMO

BACKGROUND: Mid-rectal cancer treatment traditionally involves conventional laparoscopic-assisted resection (CLAR). This study aimed to assess the clinical and therapeutic advantages of Natural Orifice Specimen Extraction Surgery (NOSES) over CLAR. AIMS: To compare the clinical outcomes, intraoperative metrics, postoperative recovery, complications, and long-term prognosis between NOSES and CLAR groups. MATERIALS & METHODS: A total of 136 patients were analyzed, with 92 undergoing CLAR and 44 undergoing NOSES. Clinical outcomes were evaluated, and propensity score matching (PSM) was employed to control potential biases. RESULTS: The NOSES group exhibited significant improvements in postoperative recovery, including lower pain scores on days 1, 3, and 5 (p < .001), reduced need for additional analgesics (p = .02), shorter hospital stays (10.8 ± 2.3 vs. 14.2 ± 5.3 days; p < .001), and decreased intraoperative blood loss (48.1 ± 52.7 mL vs. 71.0 ± 55.0 mL; p = .03). Patients undergoing NOSES also reported enhanced satisfaction with postoperative abdominal appearance and better quality of life. Additionally, the NOSES approach resulted in fewer postoperative complications. CONCLUSION: While long-term outcomes (overall survival, disease-free survival, and local recurrence rates) were comparable between the two methods, NOSES demonstrated superior postoperative outcomes compared to CLAR in mid-rectal cancer treatment, while maintaining similar long-term oncological safety. These findings suggest that NOSES could serve as an effective alternative to CLAR without compromising long-term results.


Assuntos
Laparoscopia , Cirurgia Endoscópica por Orifício Natural , Neoplasias Retais , Humanos , Feminino , Laparoscopia/métodos , Laparoscopia/efeitos adversos , Masculino , Neoplasias Retais/cirurgia , Neoplasias Retais/patologia , Neoplasias Retais/mortalidade , Pessoa de Meia-Idade , Idoso , Cirurgia Endoscópica por Orifício Natural/métodos , Cirurgia Endoscópica por Orifício Natural/efeitos adversos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Tempo de Internação/estatística & dados numéricos , Resultado do Tratamento , Qualidade de Vida , Pontuação de Propensão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...