Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Rev Esp Cardiol (Engl Ed) ; 74(8): 700-707, 2021 Aug.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32800747

RESUMO

INTRODUCTION AND OBJECTIVES: To help to illustrate the trends in isolated surgical aortic valve replacement (SAVR) in Spain, we performed a national-level analysis to investigate the changes from 1998 to 2017 in a) SAVR volume, b) patients' risk profiles, c) in-hospital mortality, and d) types of aortic valve prostheses. METHODS: We included all episodes of patients undergoing isolated SAVR from January 1998 to December 2017 recorded in the Minimum Basic Data Set (Ministry of Health, Consumer Affairs, and Social Welfare, Spain). The study duration was divided into four 5-year periods. We analyzed the trends in SAVR volume, comorbidity prevalence, and in-hospital mortality. Through multivariate logistic regression, we identified factors associated with mortality and type of prosthesis. The risk-adjusted mortality rate was compared over the study period. RESULTS: In total, 73 668 patients underwent an isolated SAVR from 1998 to 2017. The annual volume of procedures increased from 16 363 between 1998 and 2002 to 22 685 between 2013 and 2017. The prevalence of all investigated comorbidities increased, except for history of previous myocardial infarction and unplanned admission. The Charlson comorbidity index worsened from 1998-2002 (2.3; SD, 1.4) to 2013-2017 (3.6; SD, 1.7) (P <.001). In-hospital mortality decreased from 7.2% to 3.3% (P <.001) while the risk-adjusted mortality index improved from 1.3 to 0.7. The proportion of bioprostheses increased from 20.7% (1998-2002) to 59.6% (2013-2017) (P <.001). CONCLUSIONS: We detected an increase in the annual SAVR volume in Spain, with more patients receiving bioprostheses. Despite an increased risk profile of the patients, in-hospital mortality substantially reduced.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Mortalidade Hospitalar , Humanos , Fatores de Risco , Espanha/epidemiologia , Resultado do Tratamento
2.
Rev. urug. cardiol ; 36(3): e203, 2021. ilus, tab
Artigo em Espanhol | LILACS, UY-BNMED, BNUY | ID: biblio-1366959

RESUMO

Introducción: la degeneración valvular protésica es un problema clínico; los métodos de imagen convencionales permiten diagnosticarla en las últimas etapas. La tomografía por emisión de positrones (PET) con 18Ffluoruro puede detectar de manera precoz la degeneración subclínica. Objetivo: correlacionar parámetros de deterioro estructural protésico por PET con parámetros hemodinámicos ecocardiográficos al año de la sustitución valvular aórtica (SVA) por bioprótesis porcina. Métodos: estudio prospectivo ad hoc de un ensayo clínico. Se reclutaron pacientes sometidos a SVA por bioprótesis porcina en dos centros nacionales entre el 01/01/2019 y el 13/02/2020. Se realizaron controles clínicos y ecocardiográficos. Se seleccionaron aleatoriamente 19 sujetos a los que se les realizó PET 18Ffluoruro de sodio con angiotomografía al año de la SVA. Se midió la captación del trazador en la válvula (SUVavV) y aurícula derecha (SUVavA), calculando el índice SUVavV/SUVavA, que se comparó con los gradientes ecocardiográficos medio y máximo al año, mediante análisis de correlación de Spearman. Resultados: de 140 sujetos sometidos a SVA se realizó PET a 19, a los 16,3 meses (15,9-16,9) luego de la SVA. La mediana del índice SUVavV/SUVavA fue de 1,17 (1,11-1,27). Se encontró una correlación negativa moderada entre la captación de 18Ffluoruro y el gradiente medio (coeficiente de correlación -0,516, p = 0,028) y máximo (coeficiente -0,589, p = 0,010) al año. Conclusiones: en el seguimiento de los pacientes en los que se le realizó una sustitución valvular aórtica con bioprótesis, encontramos valores bajos de captación en el PET y gradientes ecocardiográficos normales con una correlación negativa moderada entre estos hallazgos


Introduction: prosthetic valve degeneration is a relevant clinical disorder; conventional imaging methods allow diagnosis in the later stages. 18Ffluoride positron emission tomography (PET) can detect subclinical degeneration earlier. Objective: correlate parameters of prosthetic structural deterioration by PET with echocardiographic hemodynamic parameters one year after aortic valve replacement (AVR) by porcine bioprosthesis. Methods: prospective ad hoc study of a clinical trial. Patients undergoing AVR by porcine bioprosthesis were recruited in two national centers between 01/01/2019 and 02/13/2020. Clinical and echocardiographic controls were carried out. 19 subjects were randomly selected and underwent 18Fsodium fluoride PET with CT angiography one year after AVR. Tracer uptake in the valve (SUVavV) and right atrium (SUVavA) was measured, creating the SUVavV/SUVavA index, which was compared with the mean and maximum gradients at one year, using Spearman's correlation analysis. Results: of a total of 140 subjects, PET was performed on 19 at 16.3 months (15.9-16.9) after the AVR. The median SUVavV/SUVavA ratio was 1.17 (1.11-1.27). A moderate negative correlation was found between. 18Ffluoride uptake and the mean gradient (correlation coefficient -0.516, p = 0.028) and maximum (coefficient of -0.589, p = 0.010) at one year. Conclusions: we found low uptake values in PET, echocardiographic gradients in normal range and no positive correlation between both parameters. It is the first national report with these imaging techniques


Introdução: a degeneração da válvula protética é um problema clínico; os métodos convencionais de imagem permitem o diagnóstico nas fases posteriores. A tomografia por emissão de pósitrons (PET) com fluoreto18F pode detectar a degeneração subclínica precocemente. Objetivo: correlacionar parâmetros de deterioração estrutural protética por PET com parâmetros hemodinâmicos ecocardiográficos após um ano da troca valvar aórtica (SVA) por bioprótese suína. Métodos: estudo ad hoc prospectivo de um ensaio clínico. Pacientes submetidos a SVA por bioprótese suína foram recrutados em dois centros nacionais entre 01/01/2019 e 13/02/2020. Foram realizados controles clínicos e ecocardiográficos. 19 indivíduos foram selecionados aleatoriamente que foram submetidos a PET com fluoreto de sódio 18F com angiotomografia um ano após AVS. A captação do traçador na válvula (SUVavV) e átrio direito (SUVavA) foi medida, criando o índice SUVavV/SUVavA, que foi comparado com os gradientes médio e máximo em um ano, usando a análise de correlação de Spearman. Resultados: de um total de 140 indivíduos submetidos a SVA, PET foi realizado em 19, em 16,3 meses (15,9-16,9) após a SVA. A proporção média de SUVavV/SUVavA foi de 1,17 (1,11-1,27). Uma correlação negativa moderada foi encontrada entre a captação de fluoreto18F e o gradiente médio (coeficiente de correlação -0,516, p = 0,028) e máximo (coeficiente de -0,589, p = 0,010) em um ano. Conclusões: encontramos valores baixos de captação na PET, gradientes ecocardiográficos dentro da normalidade, sem correlação positiva entre os dois parâmetros. É o primeiro trabalho nacional com essas técnicas de imagem


Assuntos
Humanos , Masculino , Feminino , Idoso , Valva Aórtica , Fluoreto de Sódio/administração & dosagem , Bioprótese , Falha de Prótese , Calcinose/diagnóstico por imagem , Próteses Valvulares Cardíacas , Ecocardiografia , Estudos Prospectivos , Seguimentos , Tomografia por Emissão de Pósitrons
3.
Rev. urug. cardiol ; 33(2): 1-19, ago. 2018. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-962333

RESUMO

Resumen: Introducción: tanto el uso de bioprótesis como de prótesis mecánicas en la sustitución valvular aórtica (SVA) tiene sus ventajas y desventajas en determinados grupos de pacientes. Datos internacionales no terminan de definir el beneficio a largo plazo de una u otra opción. Objetivo: estudiar el valor predictivo de sobrevida según el tipo de prótesis empleada en los pacientes sometidos a SVA. Métodos: se incluyeron pacientes operados de SVA aislada o asociada a cirugía de revascularización (CRM) desde enero de 2006 hasta diciembre de 2016. Se extrajeron las variables demográficas, operatorias y de seguimiento. Para disminuir la heterogeneidad entre ambos grupos se realizó un pareamiento por puntaje de propensión (PP). La sobrevida se evaluó de forma global y según estrato etario (< y ³ 60 años). Definimos el valor predictivo de sobrevida de cada tipo de prótesis mediante regresión de Cox. Resultados: se incluyeron 1.516 pacientes. Se implantó prótesis biológica a 1.230 pacientes (81,1%) y mecánica a 286 pacientes (18,9%). Se logró parear 145 pacientes en cada grupo. No se encontraron diferencias en la mortalidad operatoria ni en las complicaciones posoperatorias evaluadas (incidencia de accidente cerebrovascular [ACV], implante de marcapaso definitivo, requerimiento de diálisis, sangrado y complicaciones asociadas a la anticoagulación) tanto en la población global como luego del pareamiento. El uso de bioprótesis no fue predictor de sobrevida alejada en la población pareada por PP (HR=0,86, IC 95%: 0,51-1,4). En ninguno de los dos estratos etarios el tipo de prótesis fue predictor de sobrevida. Conclusión: en nuestro medio, en los pacientes sometidos a SVA la sobrevida a largo plazo es similar con ambos tipos de prótesis.


Summary: Introduction: the use of bioprosthesis and mechanical prosthesis has its advantages and disadvantages that vary according to each patient. International data do not agree on the long-term benefit in survival of either prosthesis. Objective: evaluate survival and predictive role of type of prosthesis in patients who underwent aortic valve replacement (AVR). Methods: we included patients who underwent AVR from January 2006 to December 2016. Demographic, operative and follow-up variables were extracted from the institution database. In order to decrease patient heterogeneity, propensity match (PM) was performed. Survival was analyzed globally and according to age strata (< and ³ 60 years old). Predictive role of prosthesis type was evaluated with Cox regression. Results: 1.516 patients were included. Bioprosthesis was used in 1.230 (81,1%) and mechanical in 286 (18,9%) patients; 145 PM patients were evaluated in each group. No differences were found in operative mortality and postoperative complications (stroke, pacemaker, dialysis, bleeding and anticoagulation complications) either in the global population or the PM. Use of bioprosthesis was not an independent predictor for survival in the PM (HR=0.86,95%CI:0.51-1.14). In neither of the age strata was type of prosthesis a predictor of survival. Conclusion: locally, patients who undergo AVR have similar survival regardless of the type of prosthesis.

4.
Medisan ; 16(10)oct.. 2012. tab
Artigo em Espanhol | CUMED | ID: cum-51892

RESUMO

Se efectuó un estudio observacional y analítico de casos y controles en el Servicio de Cirugía Cardiovascular del Hospital Provincial Docente Clinicoquirúrgico Saturnino Lora Torres de Santiago de Cuba, del 2001 al 2010, en los 248 pacientes a quienes se les realizó sustitución valvular aórtica, con empleo tanto de prótesis mecánica como biológica, de los cuales se tomaron como muestra los 30 fallecidos durante dicha etapa (grupo de casos) y 60 intervenidos seleccionados de forma aleatoria (grupo de controles). Pudo observarse un predominio de la estenosis aórtica, el sexo masculino y las edades avanzadas. En la serie la mortalidad resultó de 12,1 por ciento y como factores predictores de esta, mediante el análisis por regresión logística, fueron identificados: las cifras de creatinina elevadas en el período preoperatorio, el tiempo prolongado de derivación cardiopulmonar, la protección miocárdica no óptima, la recuperación cardíaca no espontánea y las complicaciones neurológicas(AU)


An observational and analytic case-control study was carried out in the Cardiovascular Surgery Department of Saturnino Lora Torres Provincial Teaching Clinical-Surgical Hospital in Santiago de Cuba, from 2001 to 2010, in the 248 patients to whom an aortic valvar replacement was carried out, with the use of both mechanical and biological prosthesis, of which the 30 deaths during this stage (cases group) and 60 surgically treated selected at random (controls group) were taken as samples. A prevalence of aortic stenosis, the male sex and the advanced ages could be observed. In the series mortality was 12.1 percent and as predictors of it, by means of the logistical regression analysis, there were: the levels of high creatinine in the preoperative period, the long time of cardiopulmonary bypass, non optimal myocardial protection, non spontaneous heart recovery and the neurological complications(AU)


Assuntos
Humanos , Masculino , Feminino , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Cirurgia Torácica , Estudos Observacionais como Assunto , Estudos de Casos e Controles
5.
Medisan ; 16(10): 1504-1512, oct. 2012.
Artigo em Espanhol | LILACS | ID: lil-660101

RESUMO

Se efectuó un estudio observacional y analítico de casos y controles en el Servicio de Cirugía Cardiovascular del Hospital Provincial Docente Clinicoquirúrgico "Saturnino Lora Torres" de Santiago de Cuba, del 2001 al 2010, en los 248 pacientes a quienes se les realizó sustitución valvular aórtica, con empleo tanto de prótesis mecánica como biológica, de los cuales se tomaron como muestra los 30 fallecidos durante dicha etapa (grupo de casos) y 60 intervenidos seleccionados de forma aleatoria (grupo de controles). Pudo observarse un predominio de la estenosis aórtica, el sexo masculino y las edades avanzadas. En la serie la mortalidad resultó de 12,1 % y como factores predictores de esta, mediante el análisis por regresión logística, fueron identificados: las cifras de creatinina elevadas en el período preoperatorio, el tiempo prolongado de derivación cardiopulmonar, la protección miocárdica no óptima, la recuperación cardíaca no espontánea y las complicaciones neurológicas.


An observational and analytic case-control study was carried out in the Cardiovascular Surgery Department of "Saturnino Lora Torres" Provincial Teaching Clinical-Surgical Hospital in Santiago de Cuba, from 2001 to 2010, in the 248 patients to whom an aortic valvar replacement was carried out, with the use of both mechanical and biological prosthesis, of which the 30 deaths during this stage (cases group) and 60 surgically treated selected at random (controls group) were taken as samples. A prevalence of aortic stenosis, the male sex and the advanced ages could be observed. In the series mortality was 12.1% and as predictors of it, by means of the logistical regression analysis, there were: the levels of high creatinine in the preoperative period, the long time of cardiopulmonary bypass, non optimal myocardial protection, non spontaneous heart recovery and the neurological complications.

6.
Rev. urug. cardiol ; 24(1): 5-12, mayo 2009. tab
Artigo em Espanhol | LILACS | ID: lil-566614

RESUMO

La incidencia de desproporción prótesis-paciente (DPP), expresada como área del orificio efectivo indexada (AOEI), varía entre 19%-70% y su efecto sobre la morbimortalidad es controvertido. Esto es de interés debido a la frecuencia del procedimiento. Objetivo: determinar la incidencia acumulada de DPP y mortalidad quirúrgica en pacientes elegidos para cirugía de sustitución valvular aórtica (CSVA). Material y método: entre enero de 2004 y junio de 2007 se realizaron 131 CSVA en portadores de estenosis aórtica. Caso incidente de DPP: si AOEI < 0,85 cm2/m2; moderada, entre 0,85- 0,65 y severa < 0,65. En 13 (9,9%) no fue posible determinar el área del orificio efectivo (AOE). La mortalidad quirúrgica se considera según la Society of Thoracic Surgeons (EE.UU.). Las incidencias acumuladas (IC95%) se calcularon estratificadas por severidad de la DPP. La asociación DPP - mortalidad quirúrgica se exploró por probabilidad exacta. Resultado: la incidencia acumulada de DPP fue 41/118 (34,7%, IC95%: 26%-44%), moderada en 26/118 pacientes (22,0%, IC95%: 15%-31%) y severa en 15/118 (12,7%, IC95%: 7%-20%). En todos, la mortalidad quirúrgica fue 10/131 (7,6%, IC95%: 4%-14%), y en los que se estimó DPP fue 9/118 (7,6%, IC95%: 4%-14%). En los pacientes sin DPP fue 6/77 (7,8%, IC95%: 3%-17%) similar a los con DPP que fue 3/41 (7,3%, IC95%: 2%-20%), p=1. En la DPP moderada la mortalidad quirúrgica fue 1/26 (3,8% IC95%: 1%-19%) y en DPP severa 2/15 (13%, IC95%: 2%-40%). Conclusión: más del 30% de los pacientes con CSVA tuvieron DPP, siendo severa en 13%. No se encontró asociación entre DPP y mortalidad quirúrgica.


The incidence of prosthesis-patient mismatch (PPM) expressed as the indexed effective orifice area (IEOA) varies between 19%-70% and its effect on morbidity and mortality is controversial. This is of interest because the frequency of the procedure.Objective: determine cumulative incidence of PPM and surgical mortality in patients selected for aortic valve replacement surgery (AVRS). Material and method: between January 2004 and June 2007, 131 surgeries for aortic stenosis were done. PPM incident case if AOEI <0,85 cm2/m2; moderate between 0,85-0,65 and severe <0,65. In 13 (9,9%) was not possible to determine EOA. Surgical mortality is considered as the Society of Thoracic Surgeons, USA. The cumulative incidence (95% CI) were calculated stratified by severity of the PPM. The association PPM - surgical mortality was explored by exact test. Results: The cumulative incidence of PPM was 41/118 (34,7%, 95% CI: 26%-44%), moderate in 26/118 patients (22,0%, 95% CI: 15%-31%) and severe in 15/118 (12,7 %, 95% CI: 7%-20%). In all the surgical mortality was 10/131 (7,6%, 95% CI: 4%-14%), and the PPM was estimated to be 9 / 118 (7,6%, 95% CI: 4%-14%). In patients without PPM was 6 / 77 (7,8%, 95% CI: 3%-17%) similar to the PPM which was 3 / 41 (7,3%, 95% CI: 2%-20%), p=1. In the PPM moderate surgical mortality was 1/26 (3,8%, 95% CI: 1%-19%) and severe PPM 2/15 (13%, 95% CI: 2%-40%). Conclusion: more than 30% of patients with AVRS had PPM, being severe in 13%. No association was found between PPM and surgical mortality.


Assuntos
Humanos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Valva Aórtica/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...