Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-34712407

RESUMO

Background. This study aimed to compare the cyclic fatigue resistance of ProTaper Next, Hyflex CM, 2Shape, and TF-Adaptive nickel-titanium endodontic file systems with various alloy properties and production methods and investigate the fractured cross-sectional surface of files due to cyclic fatigue by scanning electron microscopy (SEM). Methods. A total of 120 instruments were used (n=30). For standardization, #25/.06 apical diameter and taper angle were selected for each file system. The experiment of files was subjected to a static cyclic fatigue model. The time for files' failure was recorded with a digital chronometer and multiplied by the rotation speed to calculate the number of cycles. Kolmogorov-Smirnov, one-way ANOVA, and post hoc Bonferroni analysis were used for statistical analysis. Statistical significance was set at P < 0.05. Results. The number of cycles for the failure of files was compared between the groups, and significant differences were found (P < 0.05). The number of cycles for instrument failure was recorded from the highest to the lowest as follows: Hyflex CM, TF-Adaptive, ProTaper Next, and 2Shape. Conclusion. The files were fractured at different average numbers of cycles in an artificial canal in all the groups. The Hyflex CM demonstrated better cyclic fatigue resistance than TF Adaptive, ProTaper Next, and 2Shape file systems. Factors such as production patterns, alloy properties, and the phase in which the files were produced might affect the lifespan of file systems.

2.
Artigo em Inglês | MEDLINE | ID: mdl-34386176

RESUMO

Background. This study aimed to evaluate the effects of repeated sterilization cycles on the surface alterations of various nickel-titanium instruments, including ProTaper Next (PTN), TF Adaptive (TFA), HyFlex CM (HCM), and 2Shape (2S). Methods. Twenty-four new NiTi files of four different alloys were selected. The instruments in each group were divided into two equal groups, as follows: control and sterilization. The first group was chosen as the control without applying any sterilization procedure, while in group 2, five cycles of sterilization procedures were applied. The surface topographies were evaluated using scanning electron microscope (SEM) and atomic force microscope (AFM). The root mean square (RMS) and maximum height (MH) values and three-dimensional images were recorded. The data were analyzed with the Shapiro-Wilk test, one-way ANOVA, and post hoc Tukey tests. The statistical significance level was set at P ≤ 0.05. Results. Before the experiment, HCM demonstrated the highest RMS value, and 2S showed the lowest. After the procedures, the RMS and MH values deteriorated on the surface of PTX, TFA, and 2S (P < 0.001). The HCM was not affected by sterilization processes (P > 0.05). Conclusion. The initial irregularity on the surface did not affect the rate of alteration. The HCM files demonstrated superior surface properties after several cycles of sterilization. The PTN, TFA, and 2S presented similar surface responses after five cycles of autoclave sterilization.

3.
Materials (Basel) ; 14(3)2021 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-33499266

RESUMO

We aimed to analyze the morpho-geometric changes of the root canal system created by two rotary systems (TF Adaptive and BioRace) using micro-CT technology. Two concepts of rotary file system kinematics, continuous rotation and adaptive kinematics, were used in root canal preparation. Twenty mandibular molars (n = 20) were selected with the following criteria: the teeth have mesial roots with a single and continuous isthmus connecting the mesiobuccal and mesiolingual canals (Vertucci's Type I configuration) and distal roots with independent canals. Teeth were scanned at a resolution of 14 µm. Canals were divided equally into two groups and then enlarged sequentially using the BioRace system and TF Adaptive system according to manufacturer protocol. Co-registered images, before and after preparation, were evaluated for morphometric measurements of canal surface area, volume, structure model index, thickness, straightening, and un-instrumented surface area. Before and after preparation, data were statistically analyzed using a paired sample t-test. After preparation, data were analyzed using an unpaired sample test. The preparation by both systems significantly changed canal surface area, volume, structure model index, and thickness in both systems. There were no significant differences between instrument types with respect to these parameters (p > 0.05). TF Adaptive was associated with less straightening (8% compared with 17% for BioRace in the mesial canal, p > 0.05). Both instrumentation systems produced canal preparations with adequate geometrical changes. BioRace straightened the mesial canals more than TF Adaptive.

4.
Odontology ; 109(3): 568-573, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33245455

RESUMO

Torsional stresses are one of the most frequent causes of intracanal separation of nickel-titanium endodontic instruments, which represents a great concern of endodontists. For this reason, torsional resistance of rotary instruments has been deeply investigated by determining all parameters that can influenced it, that can be summarized in: (1) Tooth-related factors, (2) Strategy-related factors and (3) Instrument-related factors. This study was conducted to examine the influence of shaft length on torsional resistance of a nickel-titanium rotary instrument and if it should be considered as an Instrument-related factor. With this aim, 120 Twisted Files Adaptive M-L (TFA M-L) NiTi instruments (SybronEndo, Orange, CA, USA) were divided into 6 experimental groups (n = 20), according to instruments length and size: Group 1, 20 TFA M-L1 25/08 23 mm; Group 2, 20 TFA M-L1 25/08 27 mm; Group 3, 20 TFA M-L2 35/06 23 mm; Group 4, 20 TFA M-L2 35/06 27 mm; Group 5, 20 TFA M-L3 50/04 23 mm; and Group 6, 20 TFA M-L3 50/04 27 mm. All instruments were submitted to a static torsional test, blocking each instrument at 3 mm from the tip and rotating it until its fracture. Torque to Fracture (TtF) and fragments length were registered and all data were statistically analyzed. Results showed that Groups 2, 4 and 6 had a higher TtF, respectively, than Groups 1, 3 and 5, which differ from the former just for shaft length. Group 6 showed the highest torsional resistance (1.31 ± 0.08 Ncm), whilst Group 1 the lowest (0.40 ± 0.08 Ncm). According to that, it can be stated that the longer the instrument, the higher the torsional resistance is, proving that shaft length should be considered as an important factor about torsional resistance.


Assuntos
Níquel , Titânio , Ligas Dentárias , Instrumentos Odontológicos , Desenho de Equipamento , Falha de Equipamento , Teste de Materiais , Preparo de Canal Radicular , Estresse Mecânico , Torque , Torção Mecânica
5.
Odontology ; 108(2): 213-221, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31531770

RESUMO

The aim of the present study was to investigate and compare the surface deformations of different NiTi rotary files after retreatment under scanning electron microscope (SEM). A total of 240 upper central incisor teeth were obturated with vertical compaction technique and divided into 6 groups. Root canals were retreated by ProTaper Next (PTN), Twisted File Adaptive (TFA), Reciproc (RPC), ProTaper Universal Retreatment (PTR), R-Endo and Mtwo-R NiTi rotary systems. The files investigated under SEM at different magnifications and photomicrographs were captured. The photomicrographs were classified and scored. Kruskal-Wallis and Dunn tests were performed for statistical analyze at 5% significance level. PTR and RPC groups were free of defects like file separation, curving and unwinding but PTN and TFA groups showed 50% file separation. According to the photomicrographs that were captured at high magnification; there were no statistically difference between groups at the coronal thirds of the files (P > 0.05), at the middle third PTN and TFA groups showed statistically more deformation than the other groups (P < 0.05). At the apical third Reciproc was statistically showed less deformation than the other all groups (P < 0.05). Within the limitation of this in vitro study, all NiTi files showed surface deformation in SEM observation after retreatment procedures. There was less deformation in PTR and RPC groups according to other.


Assuntos
Níquel , Materiais Restauradores do Canal Radicular , Cavidade Pulpar , Desenho de Equipamento , Guta-Percha , Microscopia Eletrônica de Varredura , Preparo de Canal Radicular , Titânio
6.
J Endod ; 45(10): 1237-1241, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31420109

RESUMO

INTRODUCTION: The goal of this study was to compare the cyclic fatigue resistance of 5 heat-treated nickel-titanium files in reciprocating movement with the same tip size and different cross sections. METHODS: Five groups (WaveOne [Dentsply, Ballaigues, Switzerland], WaveOne GOLD [Dentsply], RECIPROC [VDW, Munich, Germany], RECIPROC BLUE [VDW GmbH, Munich, Germany], and TF [Sybron Endo, Glendora, CA] Adaptive) of 24 files each of the rotary files were examined. Cyclic fatigue resistance was compared between groups by determining the time needed to fracture and the number of cycles to failure in a cyclic fatigue testing device with 2 different curvatures, the first with a 5-mm radius of curvature and a 60° angle and the second with a double curvature, coronal curvature of 60° angle and a radius of 5 mm, and an apical curvature of 70° angle and a 2-mm radius. Scanning electron microscopic evaluation was performed at the fracture sites to investigate the types of fracture. RESULTS: RECIPROC BLUE group had a higher mean time to fracture followed by RECIPROC and WaveOne GOLD for both single and double curvature. WaveOne had a higher mean time to fracture in a single curvature canal than TF Adaptive, whereas the opposite was true for a double curvature canal. Both RECIPROC groups were significantly greater in cyclic fatigue resistance in comparison with all other groups (P < .05). WaveOne GOLD was significantly greater than the WaveOne and TF Adaptive groups (P < .05). CONCLUSIONS: RECIPROC BLUE files exhibited significantly greater cyclic fatigue resistance compared with other files tested in an S-shaped artificial canal.


Assuntos
Instrumentos Odontológicos , Níquel , Preparo de Canal Radicular , Titânio , Desenho de Equipamento , Falha de Equipamento , Alemanha , Temperatura Alta , Teste de Materiais , Estresse Mecânico
7.
Restor Dent Endod ; 42(3): 224-231, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28808639

RESUMO

OBJECTIVES: To determine the actual revolutions per minute (rpm) values and compare the cyclic fatigue life of Reciproc (RPC, VDW GmbH), WaveOne (WO, Dentsply Maillefer), and TF Adaptive (TFA, Axis/SybronEndo) nickel-titanium (NiTi) file systems using high-speed camera. MATERIALS AND METHODS: Twenty RPC R25 (25/0.08), 20 WO Primary (25/0.08), and 20 TFA ML 1 (25/0.08) files were employed in the present study. The cyclic fatigue tests were performed using a dynamic cyclic fatigue testing device, which has an artificial stainless steel canal with a 60° angle of curvature and a 5-mm radius of curvature. The files were divided into 3 groups (group 1, RPC R25 [RPC]; group 2, WO Primary [WO]; group 3, TF Adaptive ML 1 [TFA]). All the instruments were rotated until fracture during the cyclic fatigue test and slow-motion videos were captured using high-speed camera. The number of cycles to failure (NCF) was calculated. The data were analyzed statistically using one-way analysis of variance (ANOVA, p < 0.05). RESULTS: The slow-motion videos were indicated that rpm values of the RPC, WO, and TFA groups were 180, 210, and 425, respectively. RPC (3,464.45 ± 487.58) and WO (3,257.63 ± 556.39) groups had significantly longer cyclic fatigue life compared with TFA (1,634.46 ± 300.03) group (p < 0.05). There was no significant difference in the mean length of the fractured fragments. CONCLUSIONS: Within the limitation of the present study, RPC and WO NiTi files showed significantly longer cyclic fatigue life than TFA NiTi file.

8.
Artigo em Inglês | MEDLINE | ID: mdl-28748049

RESUMO

Background. The aim of this study was to compare the dentinal defects caused by Reciproc, TF Adaptive and ProTaper Next NiTi rotary file systems during the retreatment procedure. Methods. A total of 150 mandibular incisors with straight and single root canals were included in the present study. All the root canals were prepared up to an apical diameter 0.40 mm using stainless steel files. Thirty teeth were randomly stored as the negative control group. A total of 120 specimens were obturated with gutta-percha and AH Plus sealer using vertical compaction technique. Thirty specimens with root canal filling were randomly separated for the only-filled group. Then the teeth were randomly divided into 3 groups; Reciproc, TF Adaptive and ProTaper Next. The retreatment procedure was performed with these NiTi files. Then 150 specimens were cut perpendicular to tooth axis at 3-, 6-, and 9-mm distances from the apex, and examined to determine the presence of any cracks at ×25 under a stereomicroscope. Chi-squared test was used at 5% significance level. Results. All the tested NiTi file systems were found to cause significantly more dentinal defects compared to unprepared and only-filled groups (P<0.05). No statistically significant differences were found between the groups in terms of dentinal defects (P>0.05). No correlation was found between the slice levels and the dentinal defect distribution (P>0.05). Conclusion. Within the limitations of present study, all the tested NiTi file systems were found to cause significantly more dentinal defects compared to unprepared and only-filled groups.

9.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-23634

RESUMO

OBJECTIVES: To determine the actual revolutions per minute (rpm) values and compare the cyclic fatigue life of Reciproc (RPC, VDW GmbH), WaveOne (WO, Dentsply Maillefer), and TF Adaptive (TFA, Axis/SybronEndo) nickel-titanium (NiTi) file systems using high-speed camera. MATERIALS AND METHODS: Twenty RPC R25 (25/0.08), 20 WO Primary (25/0.08), and 20 TFA ML 1 (25/0.08) files were employed in the present study. The cyclic fatigue tests were performed using a dynamic cyclic fatigue testing device, which has an artificial stainless steel canal with a 60° angle of curvature and a 5-mm radius of curvature. The files were divided into 3 groups (group 1, RPC R25 [RPC]; group 2, WO Primary [WO]; group 3, TF Adaptive ML 1 [TFA]). All the instruments were rotated until fracture during the cyclic fatigue test and slow-motion videos were captured using high-speed camera. The number of cycles to failure (NCF) was calculated. The data were analyzed statistically using one-way analysis of variance (ANOVA, p < 0.05). RESULTS: The slow-motion videos were indicated that rpm values of the RPC, WO, and TFA groups were 180, 210, and 425, respectively. RPC (3,464.45 ± 487.58) and WO (3,257.63 ± 556.39) groups had significantly longer cyclic fatigue life compared with TFA (1,634.46 ± 300.03) group (p < 0.05). There was no significant difference in the mean length of the fractured fragments. CONCLUSIONS: Within the limitation of the present study, RPC and WO NiTi files showed significantly longer cyclic fatigue life than TFA NiTi file.


Assuntos
Fadiga , Rádio (Anatomia) , Aço Inoxidável
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...