Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38697283

RESUMO

INTRODUCTION AND OBJECTIVES: The multiparametric implantable cardioverter-defibrillator HeartLogic index has proven to be a sensitive and timely predictor of impending heart failure (HF) decompensation. We evaluated the impact of a standardized follow-up protocol implemented by nursing staff and based on remote management of alerts. METHODS: The algorithm was activated in HF patients at 19 Spanish centers. Transmitted data were analyzed remotely, and patients were contacted by telephone if alerts were issued. Clinical actions were implemented remotely or through outpatient visits. The primary endpoint consisted of HF hospitalizations or death. Secondary endpoints were HF outpatient visits. We compared the 12-month periods before and after the adoption of the protocol. RESULTS: We analyzed 392 patients (aged 69±10 years, 76% male, 50% ischemic cardiomyopathy) with implantable cardioverter-defibrillators (20%) or cardiac resynchronization therapy defibrillators (80%). The primary endpoint occurred 151 times in 86 (22%) patients during the 12 months before the adoption of the protocol, and 69 times in 45 (11%) patients (P<.001) during the 12 months after its adoption. The mean number of hospitalizations per patient was 0.39±0.89 pre- and 0.18±0.57 postadoption (P<.001). There were 185 outpatient visits for HF in 96 (24%) patients before adoption and 64 in 48 (12%) patients after adoption (P<.001). The mean number of visits per patient was 0.47±1.11 pre- and 0.16±0.51 postadoption (P<.001). CONCLUSIONS: A standardized follow-up protocol based on remote management of HeartLogic alerts enabled effective remote management of HF patients. After its adoption, we observed a significant reduction in HF hospitalizations and outpatient visits.

2.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38701881

RESUMO

INTRODUCTION AND OBJECTIVES: Cardiac resynchronization therapy (CRT) is an effective treatment for patients with nonischemic dilated cardiomyopathy associated with left bundle branch block (LBBB). In these patients, the device can normalize left ventricular ejection fraction (LVEF). Nevertheless, it remains unclear whether CRT responders still require neurohormonal blockers. The aim of this study is to determine the long-term safety of withdrawing drug therapy in these patients. METHODS: The REMOVE trial is a prospective, multicenter, open-label and randomized 1:1 study designed to assess the effect of withdrawing neurohormonal blockers in patients with nonischemic dilated cardiomyopathy associated with left bundle branch block who recovered LVEF after CRT. The study will include a 12-month follow-up with the option to continue into the follow-up extension phase for up to 24 months. The primary endpoint is the recurrence of cardiomyopathy defined as any of the following criteria: a) a reduction in LVEF >10% (provided the LVEF is <50%); b) a reduction in LVEF >10% accompanied by an increase >15% in the indexed end-systolic volume relative to the previous value and in a range higher than the normal values, or c) decompensated heart failure requiring intravenous diuretic administration. In patients meeting the primary endpoint, drug therapy will be restarted. CONCLUSIONS: The results of this study will help to enhance our understanding of CRT superresponders, a specific group of patients. Registred at ClinicalTrials.gov (Identifier: NCT05151861).

3.
Arch. cardiol. Méx ; 94(1): 15-24, ene.-mar. 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1556888

RESUMO

Abstract Background: Cardiac resynchronization therapy (CRT) has been established as an effective therapy for heart failure with reduced ejection fraction. Randomized clinical trials have shown its impact on mortality and HF hospitalizations, as well as improvement of symptoms and quality of life. Objectives: Finding clinical, electrocardiographic, and echocardiographic variables that may predict the response to cardiac resynchronization therapy (CRT). Methods: We performed a single-center, observational, analytic, and retrospective study that included 102 patients with heart failure (HF) diagnosis who underwent CRT according to guideline-directed therapy from January 2010 to April 2020 in a third-level center. CRT response was defined as an improvement of New York Heart Association functional class in at least 1 category associated with a recovery of ≥ 5% in the left ventricular ejection fraction (LVEF). Results: Our study population was 102 patients of which 61 (59.8%) were men. The mean age at HF diagnosis was 54 ± 18.7 years. Ischemic heart disease was the etiology in 37 (36.3%) cases. Fifty-one (50%) patients were classified as responders. Responders had wider QRS, and lower LVEF and right ventricular fractional area change at baseline. After CRT, responders had a greater reduction of QRS duration, and improvement in LVEF, global longitudinal strain, and echocardiographic dyssynchrony parameters. Multivariate regression analysis showed that left bundle branch block (LBBB), left ventricular end-diastolic volume (LVEDV), tricuspid annular plane systolic excursion (TAPSE), and baseline difference of pre-ejection periods were predictors of a positive response to CRT in this population. Conclusions: LBBB, TAPSE, LVEDV, and pre-ejection time difference are independent variables that can predict adequate response to CRT.


Resumen Antecedentes: La terapia de resincronización cardíaca (TRC) se ha establecido como una terapia efectiva para la insuficiencia cardíaca con fracción de eyección reducida. Ensayos clínicos aleatorizados han demostrado su impacto en la mortalidad y hospitalizaciones por insuficiencia cardíaca, así como la mejora de los síntomas y la calidad de vida. Objetivos: Determinar las variables clínicas, electrocardiográficas y ecocardiográficas que puedan predecir la respuesta a la terapia de resincronización cardíaca (TRC). Método: Estudio unicéntrico, observacional, analítico, retrospectivo, que incluyó 102 pacientes con diagnóstico de IC sometidos a TRC y terapia dirigida por guías, de enero de 2010 a abril de 2020, en un centro de tercer nivel. La respuesta a TRC fue definida como mejoría de la clase funcional de la New York Heart Association en al menos 1 categoría, asociado con una recuperación ≥ 5% en la fracción de expulsión del ventrículo izquierdo (FEVI). Resultados: Incluimos a 102 pacientes, 61 (59.8%) fueron hombres. El promedio de edad al diagnóstico de IC fue 54 ± 18.7 años. La cardiopatía isquémica fue la etiología en 37 (36.3%) pacientes. 51 (50%) pacientes, fueron clasificados como respondedores. Los respondedores presentaron QRS amplio, menor FEVI y menor fracción de acortamiento del ventrículo derecho al inicio del estudio. Después de la TRC, los respondedores tuvieron una mayor reducción en la duración del QRS, mejoría en la FEVI, strain longitudinal global y parámetros de disincronía ecocardiográfica. El análisis de regresión multivariado mostró que el bloqueo de rama izquierdo (BRI), el volumen telediastólico del ventrículo izquierdo (VTDVI) la excursión sistólica del plano anular tricuspídeo (TAPSE) y la diferencia basal del período expulsivo fueron predictores de respuesta positiva a TRC. Conclusiones: BRI, TAPSE, VTDVI y la diferencia basal de períodos preexpulsivos son variables independientes que predicen respuesta adecuada a TRC.

4.
Arch Cardiol Mex ; 94(1): 15-24, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38507305

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) has been established as an effective therapy for heart failure with reduced ejection fraction. Randomized clinical trials have shown its impact on mortality and HF hospitalizations, as well as improvement of symptoms and quality of life. OBJECTIVES: Finding clinical, electrocardiographic, and echocardiographic variables that may predict the response to cardiac resynchronization therapy (CRT). METHODS: We performed a single-center, observational, analytic, and retrospective study that included 102 patients with heart failure (HF) diagnosis who underwent CRT according to guideline-directed therapy from January 2010 to April 2020 in a third-level center. CRT response was defined as an improvement of New York Heart Association functional class in at least 1 category associated with a recovery of ≥ 5% in the left ventricular ejection fraction (LVEF). RESULTS: Our study population was 102 patients of which 61 (59.8%) were men. The mean age at HF diagnosis was 54 ± 18.7 years. Ischemic heart disease was the etiology in 37 (36.3%) cases. Fifty-one (50%) patients were classified as responders. Responders had wider QRS, and lower LVEF and right ventricular fractional area change at baseline. After CRT, responders had a greater reduction of QRS duration, and improvement in LVEF, global longitudinal strain, and echocardiographic dyssynchrony parameters. Multivariate regression analysis showed that left bundle branch block (LBBB), left ventricular end-diastolic volume (LVEDV), tricuspid annular plane systolic excursion (TAPSE), and baseline difference of pre-ejection periods were predictors of a positive response to CRT in this population. CONCLUSIONS: LBBB, TAPSE, LVEDV, and pre-ejection time difference are independent variables that can predict adequate response to CRT.


ANTECEDENTES: La terapia de resincronización cardíaca (TRC) se ha establecido como una terapia efectiva para la insuficiencia cardíaca con fracción de eyección reducida. Ensayos clínicos aleatorizados han demostrado su impacto en la mortalidad y hospitalizaciones por insuficiencia cardíaca, así como la mejora de los síntomas y la calidad de vida. OBJETIVOS: Determinar las variables clínicas, electrocardiográficas y ecocardiográficas que puedan predecir la respuesta a la terapia de resincronización cardíaca (TRC). MÉTODO: Estudio unicéntrico, observacional, analítico, retrospectivo, que incluyó 102 pacientes con diagnóstico de IC sometidos a TRC y terapia dirigida por guías, de enero de 2010 a abril de 2020, en un centro de tercer nivel. La respuesta a TRC fue definida como mejoría de la clase funcional de la New York Heart Association en al menos 1 categoría, asociado con una recuperación ≥ 5% en la fracción de expulsión del ventrículo izquierdo (FEVI). RESULTADOS: Incluimos a 102 pacientes, 61 (59.8%) fueron hombres. El promedio de edad al diagnóstico de IC fue 54 ± 18.7 años. La cardiopatía isquémica fue la etiología en 37 (36.3%) pacientes. 51 (50%) pacientes, fueron clasificados como respondedores. Los respondedores presentaron QRS amplio, menor FEVI y menor fracción de acortamiento del ventrículo derecho al inicio del estudio. Después de la TRC, los respondedores tuvieron una mayor reducción en la duración del QRS, mejoría en la FEVI, strain longitudinal global y parámetros de disincronía ecocardiográfica. El análisis de regresión multivariado mostró que el bloqueo de rama izquierdo (BRI), el volumen telediastólico del ventrículo izquierdo (VTDVI) la excursión sistólica del plano anular tricuspídeo (TAPSE) y la diferencia basal del período expulsivo fueron predictores de respuesta positiva a TRC. CONCLUSIONES: BRI, TAPSE, VTDVI y la diferencia basal de períodos preexpulsivos son variables independientes que predicen respuesta adecuada a TRC.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Volume Sistólico/fisiologia , Estudos Retrospectivos , Qualidade de Vida , Resultado do Tratamento , Função Ventricular Esquerda , Bloqueio de Ramo/terapia
5.
Arch Cardiol Mex ; 93(Supl): 39-53, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37918411

RESUMO

Epidemiological studies suggest that approximately half of the patients with heart failure (HF) have reduced ejection fraction, while the other half have normal ejection fraction (EF). Currently, international guidelines consider QRS duration greater than 130 ms, in the presence of ventricular dysfunction (EF < 35%), as a criterion for selecting patients for cardiac resynchronization therapy (CRT). CRT helps restore intraventricular and auriculoventricular synchrony, improving left ventricular (LV) performance, reducing functional mitral regurgitation, and inducing reverse LV remodeling. This is evidenced by increased LV filling time and left ventricular ejection fraction, decreased LV end-diastolic and end-systolic volumes, mitral regurgitation, and septal dyskinesia. Because the mechanisms of dyssynchrony may be heterogeneous, no single measure may accurately predict response to CRT. Finally, CRT has been progressively shown to be safe and feasible, improves functional status and quality of life, reversely remodels the LV, decreases the number of hospitalizations, total mortality in patients with refractory HF, LV dysfunction, and intraventricular conduction disorders; is a pacemaker-based therapy for HF and thanks to current technology, safe remote monitoring of almost all types of cardiac devices is possible and provides useful alerts in clinical practice.


Los estudios epidemiológicos sugieren que aproximadamente la mitad de los pacientes con insuficiencia cardiaca (IC) tiene fracción de eyección reducida, mientras que la otra mitad, fracción de eyección (FE) normal. Actualmente, las guías internacionales consideran la duración de QRS mayor a 130 ms, en presencia de disfunción ventricular (FE < 35%), como criterio para selección de pacientes a terapia de resincronización cardiaca (TRC). La TRC ayuda a restaurar la sincronía intraventricular y auriculoventricular, mejorando el rendimiento del ventrículo izquierdo (VI), reduciendo la regurgitación mitral funcional e induciendo la remodelación inversa del VI. Esto se evidencia en el aumento del tiempo de llenado del VI y la fracción de eyección del VI, la disminución de los volúmenes telediastólico y telesistólico del VI, y la regurgitación mitral y discinesia septal. Como los mecanismos de la disincronía pueden ser heterogéneos, es posible que ninguna medida prediga con exactitud la respuesta a la TRC. Finalmente, la TRC cardiaca ha demostrado progresivamente ser segura y factible, mejora el estado funcional y la calidad de vida, remodela inversamente el VI, disminuye el número de hospitalizaciones, la mortalidad total en pacientes con IC refractaria, la disfunción ventricular izquierda y los trastornos de conducción intraventricular; es una terapia basada en marcapasos para la IC y gracias a la tecnología actual es posible realizar una supervisión remota y segura de casi todos los tipos de dispositivos cardiacos y obtener alertas útiles en la práctica clínica.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiologia , Insuficiência Cardíaca , Insuficiência da Valva Mitral , Disfunção Ventricular Esquerda , Humanos , Volume Sistólico , América Latina , Qualidade de Vida , Função Ventricular Esquerda , Insuficiência Cardíaca/terapia , Resultado do Tratamento , Remodelação Ventricular/fisiologia
6.
Rev. argent. cardiol ; 91(1): 41-48, abr. 2023. graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1529569

RESUMO

RESUMEN Introducción : La terapia de resincronización cardíaca (TRC) se indica en pacientes que habitualmente presentan remodelado cardíaco generado por dilatación y disincronía contráctil. La TRC contribuye al remodelado reverso, relacionado con menor mortalidad y hospitalizaciones por insuficiencia cardíaca (IC). Se han observado además mejoras en la conducción intraventricular, con reducción del tiempo de activación. La cuantificación del remodelado eléctrico reverso se ha subutilizado como parámetro de respuesta, con escasos reportes sobre su asociación con la respuesta clínica-estructural. Objetivo : Analizar el remodelado eléctrico reverso intraventricular como parámetro de respuesta a la TRC. Métodos: Se incluyeron pacientes con más de 6 meses de implante. Se obtuvo un ECG con estimulación desactivada (QRS intrínseco, QRSi, post TRC), y por ecocardiograma transtorácico se definió la fracción de eyección ventricular izquierda (FEVI), el diámetro de fin de diástole del ventrículo izquierdo (DFDVI) y la presencia de insuficiencia mitral. Se clasificó a los pacientes según la respuesta clínica-estructural. El remodelado eléctrico se caracterizó con la comparación de la duración del QRS pre y post TRC y la valoración de los cambios del QRS (ΔQRSi) entre grupos. Resultados : Se incluyeron 23 pacientes. Un 39% presentó disminución >10 mseg del QRSi. Observamos un QRSi de -9,3 ± 20,7 mseg en respondedores, y 11,25 ± 18,9 mseg en no respondedores (p = 0,027), más acentuada en los hiper respondedores (ΔQRSi: -14,44 ± 17,40 mseg, p = 0,026). Las mujeres con QRS ≥150 mseg pre TRC exhibieron disminución significativa del QRSi (p = 0,0195). Conclusiones : El remodelado eléctrico reverso se comprobó en 39% de los pacientes que recibieron TRC. Observamos una relación significativa del QRSi con la respuesta clínica-estructural, mayor en hiper respondedores. Mujeres con QRS ancho pre-TRC exhiben remodelado eléctrico reverso más acentuado. Este es un parámetro de fácil acceso e interpretación durante los controles ambulatorios.


ABSTRACT Introduction : Cardiac resynchronization therapy (CRT) is indicated in patients who often present cardiac remodeling due to dilatation and contractile dyssynchrony. CRT contributes to reverse remodeling which is associated with reduced mortality and heart failure (HF) hospitalizations. Improvements in intraventricular conduction with decreased ventricular activation time have also been observed. The quantification of reverse electrical remodeling has been underused as a parameter of response, and there are few reports on its association with the clinical-structural response. Objective : To analyze intraventricular reverse electrical remodeling as a parameter of response to CRT in living individuals. Methods : We included patients implanted at least 6 months ago. A deactivated stimulation ECG (post-CRT intrinsic QRS) was obtained, and by means of transthoracic echocardiography (TTE), the left ventricular ejection fraction (LVEF), the left ventricular end-diastolic diameter (LVEDD) and the presence of mitral regurgitation were defined. Patients were classified according to their clinical-structural response. Electrical remodeling was characterized by comparing pre- and post-CRT QRS duration and assessing QRS changes (ΔiQRS) between groups. Results : A total of 23 patients were included, 39% of which showed a >10 ms decrease in iQRS. We observed a iQRS of -9.3±20.7 ms in responders, and of 11.25±18.9 ms in non-responders (p=0.027), more marked in hyper-responders (ΔiQRS: -14.44±17.40 ms, p=0.026). Women with pre-CRT QRS ≥150 ms showed a significant decrease in iQRS (p=0.0195). Conclusion : Reverse electrical remodeling was found in 39% of the patients under CRT. We noted a significant relationship between iQRS and clinical-structural response, higher in hyper-responders. Women with wider pre-CRT QRS showed more marked reverse electrical remodeling. This parameter is accessible and easy to read in outpatient visits.

7.
Repert. med. cir ; 32(2): 156-167, 2023. ilus, tab, graf
Artigo em Espanhol | LILACS, COLNAL | ID: biblio-1526462

RESUMO

Introducción: la perfusión miocárdica mediante SPECT gatillado (tomografía computarizada de emisión de fotón único) y análisis de fase permiten evaluar la disincronía mecánica y la fracción de eyección, indicando quienes podrían responder a la terapia de resincronización cardíaca. Objetivo: describir la frecuencia de disincronía miocárdica y su relación con los resultados del SPECT en el Hospital de San José de Bogotá entre mayo 2018 y febrero 2019. Metodología: estudio transversal en mayores de 18 años, con electrocardiograma de no más de 6 meses y SPECT gatillado. Para la información sociodemográfica, antecedentes cardíacos, parámetros de electrocardiograma y resultados del SPECT se empleó estadística descriptiva y análisis de correspondencias múltiples. Resultados: se incluyeron 539 pacientes con edad promedio de 68 años, 59.8% con sobrepeso y obesidad, 47.7% en clase funcional NYHA (New York Heart Association) III y IV, 48.4% fumadores y 26.9% diabéticos; 48.1% tenían cateterismo cardíaco y 45.3% infarto agudo de miocardio; en 31% la fracción de eyección del ventrículo izquierdo < 50%. La disincronía se determinó con un ancho de banda >135°; hubo disincronía en 202 pacientes (37.5%) que se relacionó con: género masculino, sobrepeso, diabetes, tabaquismo, infarto agudo del miocardio, colocación de stent, fracción de eyección del ventrículo izquierdo <40% o entre 40%-50% y dilatación isquémica transitoria (TID) >1.22 o entre 1.12-1.22. Discusión y conclusiones: el uso de la nueva herramienta del análisis de fase de medicina nuclear es factible y útil para determinar los pacientes respondedores a la terapia de resincronización cardíaca.


Introduction: Myocardial perfusion gated SPECT (simple photon emission computed tomography) with phase analysis allows the assessment of mechanical dyssynchrony and ejection fraction, for prediction of response to cardiac resynchronization therapy. Objective: to describe myocardial dyssynchrony frequency and its relationship with SPECT results at Hospital de San José de Bogotá between May 2018 and February 2019. Methodology: cross-sectional study in patients aged over 18 years, with a less than 6 months electrocardiogram and gated SPECT. Sociodemographic data, cardiovascular history, electrocardiogram parameters and SPECT results were evaluated using descriptive statistics and multiple correspondence analysis. Results: five-hundred-thirty-nine patients with a mean age of 68 years were included, 59.8% had overweight and obesity, 47.7% were NYHA (New York Heart Association) functional class III and IV, 48.4% smokers and 26.9% diabetics; 48.1% received cardiac catheterization and 45.3% had history of acute myocardial infarction; left ventricular ejection fraction was < 50% in 31%. Dyssynchrony was determined with a >135° bandwidth; dyssynchrony was evidenced in 202 patients (37.5%) and was related to male gender, overweight, diabetes, smoking, acute myocardial infarction, stent placement, left ventricular ejection fraction <40% or 40%-50% and transient ischemic dilation (TID) >1.22 or 1.12-1.22. Discussion and conclusions: the new nuclear medicine phase analysis tool is feasible and useful to identify cardiac resynchronization therapy responders.


Assuntos
Humanos
8.
Rev. esp. cardiol. (Ed. impr.) ; 75(10): 806-816, oct. 2022. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-211052

RESUMO

Introducción y objetivos La igualdad de oportunidades para acceder a avances técnicos de reconocido valor clínico debe ser una prioridad del sistema público de salud. Se analizó la variabilidad entre todas las comunidades autónomas españolas en el uso de técnicas cardiológicas con indicación ya establecida y su relación con indicadores económicos, carga de enfermedad y mortalidad hospitalaria. Métodos Se analizaron los registros de actividad de las asociaciones de la Sociedad Española de Cardiología desde 2011 a 2019 en coronariografía, intervención coronaria percutánea (ICP) general, ICP primaria, desfibrilador automático implantable (DAI), terapia de resincronización cardiaca e implante percutáneo de válvula aórtica (TAVI). Se obtuvieron índices económicos (producto interior bruto y gasto sanitario per cápita) y datos sobre frecuentación y mortalidad hospitalarias reportados en los informes RECALCAR (Recursos y Calidad en Cardiología) de la Sociedad Española de Cardiología. Se analizó el coeficiente de variación en la actividad y la correlación de esta con los índices regionales económicos, de frecuentación y la razón de mortalidad hospitalaria estandarizada por riesgo. Resultados Existe una variación notable en el uso de las tecnologías, especialmente ICP primaria (18%), DAI (22%), terapia de resincronización cardiaca (36%) y TAVI (42%). Solo se observó cierta correlación con la frecuentación de la ICP general y el DAI. No se encontró una correlación significativa entre la penetración de las técnicas y los índices económicos de riqueza y gasto. La correlación con la mortalidad hospitalaria no mostró resultados significativos, aunque es el análisis con más limitaciones, ya que estas técnicas tienen mayor impacto en la supervivencia en el medio y largo plazo. Conclusiones Los resultados del estudio, con sus limitaciones inherentes (AU)


Introduction and objectives Equal opportunities to access technical advances with recognized clinical value should be a priority of the publicly-funded health system. We analyzed variability among all the Spanish autonomous communities in the use of cardiovascular techniques with an established indication and its relationship with economic indicators, burden of disease, and hospital mortality. Method The activity registries of various Associations of the Spanish Society of Cardiology from 2011 to 2019 were analyzed for coronary angiography, overall percutaneous coronary intervention (PCI), primary PCI, implantable cardioverter-defibrillators (ICD), cardiac resynchronization therapy, and transcatheter aortic valve replacement (TAVR). Economic indices (gross domestic product and per capita health care expenditure) were obtained from public sources and data on attendance rates and mortality from the Resources and Quality in Cardiology (RECALCAR) reports of the Spanish Society of Cardiology. We analyzed the coefficient of variation for activity and the correlation of activity with regional economic indices, attendance rates, and risk-adjusted rates of in-hospital mortality. Results We identified wide variability in the use of technologies, especially for primary PCI (18%), ICD (22%), cardiac resynchronization therapy (36%), and TAVR (42%). A certain correlation with attendance rates was seen only for overall PCI and ICD. In general, no significant correlation was found between the use of the techniques and the economic indices of wealth and expenditure. The correlation with in-hospital mortality showed no significant results, although this was the analysis with the greatest limitations because the impact of these techniques on survival is exerted more in the mid- and long-term Conclusions The results of this study, despite its inherent limitations, show marked variability between autonomous communities in the use of cardiovascular technologies (AU)


Assuntos
Humanos , Mortalidade Hospitalar , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Resultado do Tratamento , Academias e Institutos , Angiografia Coronária , Cardiologia , Registros , Espanha
9.
Rev. esp. cardiol. (Ed. impr.) ; 75(9): 710-717, sept. 2022. tab
Artigo em Espanhol | IBECS | ID: ibc-208223

RESUMO

Introducción y objetivos HeartLogic es un algoritmo multiparamétrico incorporado a desfibriladores automáticos implantables (DAI). La alerta asociada predice descompensaciones de insuficiencia cardiaca (IC). Nuestro objetivo es analizar la asociación entre alertas y eventos clínicos bajo un protocolo de seguimiento común en un registro multicéntrico. Métodos Se evaluaron la fase 1 (investigadores ciegos al estado de la alerta) y las fases 2 y 3 (tras la activación de HeartLogic, según práctica local y un protocolo común respectivamente). Resultados Se incluyó a 288 pacientes en 15 centros. En fase 1, tras una media de observación de 10 meses, hubo 73 alertas (0,72 alertas/paciente-año), con 8 hospitalizaciones y 2 visitas a urgencias por IC (0,10 eventos/año-paciente). No hubo hospitalizaciones fuera del periodo de alerta. Las fases activas tuvieron una media de seguimiento de 16 (IC95%, 15-22) meses, con 277 alertas (0,89 alertas/año-paciente); 33 se asociaron con hospitalizaciones o muerte por IC, 46 con descompensaciones menores y 78 con otros eventos. La tasa de alertas inexplicables fue 0,39/año-paciente. Fuera del estado de alerta solo hubo una hospitalización y una descompensación menor. La mayoría de las alertas (el 82% en fase 2 y el 81% en fase 3; p=0,861) se gestionaron a distancia. La mediana de NT-proBNP fue superior en estado de alerta que fuera de él (7.378 frente a 1.210 pg/ml; p <0,001). Conclusiones El índice HeartLogic se asoció con descompensaciones de IC y otros eventos relevantes, con baja tasa de alertas inexplicables. Un protocolo estandarizado permitió detectar y actuar a distancia con seguridad sobre las alertas (AU)


Introduction and objectives HeartLogic is a multiparametric algorithm incorporated into implantable cardioverter-defibrillators (ICD). The associated alerts predict impending heart failure (HF) decompensations. Our objective was to analyze the association between alerts and clinical events and to describe the implementation of a protocol for remote management in a multicenter registry. Methods We evaluated study phase 1 (the investigators were blinded to the alert state) and phases 2 and 3 (after HeartLogic activation, managed as per local practice and with a standardized protocol, respectively). Results We included 288 patients from 15 centers. In phase 1, the median observation period was 10 months and there were 73 alerts (0.72 alerts/patient-y), with 8 hospitalizations and 2 emergency room admissions for HF (0.10 events/patient-y). There were no HF hospitalizations outside the alert period. In the active phases, the median follow-up was 16 (95%CI, 15-22) months and there were 277 alerts (0.89 alerts/patient-y); 33 were associated with HF hospitalizations or HF death (n=6), 46 with minor decompensations, and 78 with other events. The unexplained alert rate was 0.39 alerts/patient-y. Outside the alert state, there was only 1 HF hospitalization and 1 minor HF decompensation. Most alerts (82% in phase 2 and 81% in phase 3; P=.861) were remotely managed. The median NT-proBNP value was higher within than outside the alert state (7378 vs 1210 pg/mL; P <.001). Conclusions The HeartLogic index was frequently associated with HF-related events and other clinically relevant situations, with a low rate of unexplained events. A standardized protocol allowed alerts to be safely and remotely detected and appropriate action to be taken on them (AU)


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Insuficiência Cardíaca/diagnóstico , Desfibriladores Implantáveis , Telemonitoramento , Algoritmos , Seguimentos
10.
Rev Esp Cardiol (Engl Ed) ; 75(10): 805-815, 2022 Oct.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35688688

RESUMO

INTRODUCTION AND OBJECTIVES: Equal opportunities to access technical advances with recognized clinical value should be a priority of the publicly-funded health system. We analyzed variability among all the Spanish autonomous communities in the use of cardiovascular techniques with an established indication and its relationship with economic indicators, burden of disease, and hospital mortality. METHODS: The activity registries of various Associations of the Spanish Society of Cardiology from 2011 to 2019 were analyzed for coronary angiography, overall percutaneous coronary intervention (PCI), primary PCI, implantable cardioverter-defibrillators (ICD), cardiac resynchronization therapy, and transcatheter aortic valve replacement (TAVR). Economic indices (gross domestic product and per capita health care expenditure) were obtained from public sources and data on attendance rates and mortality from the Resources and Quality in Cardiology (RECALCAR) reports of the Spanish Society of Cardiology. We analyzed the coefficient of variation for activity and the correlation of activity with regional economic indices, attendance rates, and risk-adjusted rates of in-hospital mortality. RESULTS: We identified wide variability in the use of technologies, especially for primary PCI (18%), ICD (22%), cardiac resynchronization therapy (36%), and TAVR (42%). A certain correlation with attendance rates was seen only for overall PCI and ICD. In general, no significant correlation was found between the use of the techniques and the economic indices of wealth and expenditure. The correlation with in-hospital mortality showed no significant results, although this was the analysis with the greatest limitations because the impact of these techniques on survival is exerted more in the mid- and long-term. CONCLUSIONS: The results of this study, despite its inherent limitations, show marked variability between autonomous communities in the use of cardiovascular technologies, which is not explained by economic differences or by hospital attendance rates due to the corresponding diseases.


Assuntos
Cardiologia , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Angiografia Coronária , Mortalidade Hospitalar , Humanos , Sistema de Registros , Resultado do Tratamento
11.
Rev. argent. cardiol ; 90(1): 31-35, mar. 2022. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1407107

RESUMO

RESUMEN Introducción: La insuficiencia mitral funcional (IMF) es común en pacientes con insuficiencia cardíaca (IC). La IMF moderada/ grave (M/G) se asocia a peor pronóstico. Objetivo: Describir la prevalencia de IMF y los mecanismos involucrados en su reducción en respondedores a la terapia de resincronización cardíaca (TRC) a los 6 meses comparados con 12 y 24 meses. Métodos: Entre 2009 y 2018 fueron tratados 338 pts. Respondedores: reducción de CF NYHA ≥1 grado o aumento de la fracción de eyección ventricular izquierda (FEVI) ≥5% (absoluto). La IMF se graduó en 4 puntos: No-IMF, leve, M y G, y se la relacionó con las mediciones ecocardiográficas. Características Basales: edad 64 ±10 años, hombres 71%, CF-NYHA IIIII 92%, bloqueo de rama izquierda (BRI) 67%, QRS ≥150 ms 75%, diámetro diastólico del VI (DDVI) 68 ± 9 mm, diámetro sistólico del VI (DSVI) 52 ± 12 mm, FEVI 24 ± 7%. Resultados: La prevalencia de IMF fue del 92,6%. A los 6 meses, 86% fueron respondedores y 23% de ellos mejoraron de IMF-M/G a IMF-Leve/No-IMF. Hubo un fuerte remodelado inverso: DDVI 68 ± 10 vs 63 ± 11 mm, (p = 0,0001), DSVI 55 ± 12 vs 50 ± 13 mm, (p = 0,0006) y FEVI 25 ± 11 vs 33 ± 10%, (p = 0,00001). Comparando 6 con 12 meses 89,4% fueron respondedores, 8% mejoraron de IMF-M/G a IMF-Leve/No-IMF. Comparando 6 con 24 meses 88% fueron respondedores, 14,6% mejoraron de IMF-M/G a IMF-Leve/No-IMF. Entre 6 y 12 y 6 y 24 meses no hubo remodelado inverso significativo. Conclusiones: La prevalencia de IMF fue elevada. El mayor remodelado inverso y reducción de la IMF se observaron a los 6 meses, siendo el primero el principal mecanismo en la reducción de la IMF. Esta mejoría se sostuvo a los 12 y 24 meses.


ABSTRACT Background: Functional mitral regurgitation (FMR) is common in heart failure, and moderate/severe (M/S) FMR is associated with worse prognosis. Objective: The aim of this study was to describe the prevalence of FMR and the mechanisms involved in its reduction in responders to cardiac resynchronization therapy (CRT) at 6 months compared with 12 and 24 months. Methods: Between 2009 and 2018, 338 patients received CRT. Patients showing NYHA functional class (FC) reduction ≥1 or left ventricular ejection fraction (LVEF) absolute increase ≥5% were considered responders. Functional mitral regurgitation was graded using a 4-point scale into none-, mild-, M- and S-FMR, and was related to echocardiographic measurements. Baseline patient characteristics were: age 64±10 years, men 71%, NYHA FC II-III 92%, left bundle branch block (LBBB) 67%, QRS ≥150 ms 75%, LV diastolic diameter (LVDD) 68±9 mm, LV systolic diameter (LVSD) 52±12 mm, and LVEF 24±7%. Results: The prevalence of FMR was 92.6%. At 6 months, 86% were responders, 23% improved from M/S-FMR to mild/none-FMR and there was strong reverse remodeling: LVDD 68±10 vs. 63±11 mm, (p=0.0001), LVSD 55±12 vs. 50±13 mm, (p=0.0006) and LVEF 25±11 vs. 33±10%, (p=0.00001). Comparing 6 with 12 months, 89.4% were responders and 8% improved M/S-FMR to mild/none-FMR. Comparing 6 with 24 months, 88% were responders and 14.6% improved M/S-FMR to mild/none-FMR. Between 6 and 12 and 6 and 24 months, there was no significant reverse remodeling. Conclusions: The prevalence of FMR was high. The highest reverse remodeling and FMR reduction was observed at 6 months, the former being the main mechanism of FMR reduction. This improvement persisted at 12 and 24 months.

12.
Rev. colomb. cardiol ; 29(1): 111-114, ene.-feb. 2022. graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1376863

RESUMO

Resumen Se presenta el caso de una paciente con atrapamiento de guía al interior del seno coronario durante el procedimiento de cambio de un electrodo (Sentus ProMRI OTW BP L-85) por desalojo asociado a disfunción de la terapia de resincronización cardiaca. Durante el implante del nuevo electrodo se presentó atrapamiento y retención intravascular de la guía utilizada para su posicionamiento a nivel del seno coronario, lo cual hizo imposible su remoción. La paciente no aceptó tratamiento quirúrgico, se encuentra en vigilancia médica y permanece asintomática desde hace 3 años.


Abstract It is reported the case of a patient with guidewire trapping inside the coronary sinus during an electrode exchange procedure (Sentus ProMRI OTW BP L-85) due to dislocation associated with dysfunction of cardiac re-synchronization therapy. During the implantation of the new electrode, entrapment of the guidewire used for its positioning at the level of the coronary sinus and intravascular retention were presented, making it impossible to remove it. The patient did not accept surgical treatment and has been under medical surveillance, asymptomatic for three years.

13.
Rev Esp Cardiol (Engl Ed) ; 75(9): 709-716, 2022 Sep.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-34896031

RESUMO

INTRODUCTION AND OBJECTIVES: HeartLogic is a multiparametric algorithm incorporated into implantable cardioverter-defibrillators (ICD). The associated alerts predict impending heart failure (HF) decompensations. Our objective was to analyze the association between alerts and clinical events and to describe the implementation of a protocol for remote management in a multicenter registry. METHODS: We evaluated study phase 1 (the investigators were blinded to the alert state) and phases 2 and 3 (after HeartLogic activation, managed as per local practice and with a standardized protocol, respectively). RESULTS: We included 288 patients from 15 centers. In phase 1, the median observation period was 10 months and there were 73 alerts (0.72 alerts/patient-y), with 8 hospitalizations and 2 emergency room admissions for HF (0.10 events/patient-y). There were no HF hospitalizations outside the alert period. In the active phases, the median follow-up was 16 (95%CI, 15-22) months and there were 277 alerts (0.89 alerts/patient-y); 33 were associated with HF hospitalizations or HF death (n=6), 46 with minor decompensations, and 78 with other events. The unexplained alert rate was 0.39 alerts/patient-y. Outside the alert state, there was only 1 HF hospitalization and 1 minor HF decompensation. Most alerts (82% in phase 2 and 81% in phase 3; P=.861) were remotely managed. The median NT-proBNP value was higher within than outside the alert state (7378 vs 1210 pg/mL; P <.001). CONCLUSIONS: The HeartLogic index was frequently associated with HF-related events and other clinically relevant situations, with a low rate of unexplained events. A standardized protocol allowed alerts to be safely and remotely detected and appropriate action to be taken on them.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Algoritmos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Hospitalização , Humanos , Sistema de Registros
14.
Rev. colomb. anestesiol ; 49(4): e301, Oct.-Dec. 2021. tab, graf
Artigo em Inglês | LILACS, COLNAL | ID: biblio-1341240

RESUMO

Abstract Patients with implantable electric stimulation devices are challenging to the anesthesiologist since these cases demand a comprehensive knowledge about how the device operates, the indications for the implant and the implications that must be addressed during the perioperative period. This article is intended to provide the reader with clear and structured information so that the anesthesiologist will be able to safely deal with the situation of a patient with an implantable cardiac stimulation device, who has been programmed for emergent surgery. A search for the scientific evidence available was conducted in Pubmed / Medline, ScienceDirect, OVID, SciELO), for a non-systematic review. The incidence of the use of cardiac electric stimulation devices has been growing. Their operation is increasingly complex, and demands being constantly updated on the knowledge in the area.


Resumen El paciente portador de un dispositivo de estimulación eléctrica cardiaca implantable se convierte en un reto para el anestesiólogo debido a que implica un conocimiento integral que abarca su funcionamiento, las indicaciones que llevaron a su implante y las implicaciones que se deben abordar en el perioperatorio. Este artículo busca proporcionar al lector información clara y estructurada que le permita al anestesiólogo enfrentarse de forma segura al escenario de un paciente con un dispositivo de estimulación eléctrica cardiaca implantable programado para cirugía emergente. Se realizó una búsqueda de la evidencia científica disponible en bases de datos (Pubmed / Medline, ScienceDirect, OVID, SciELO), para una revisión no sistemática. La incidencia en el uso de dispositivos de estimulación eléctrica cardiaca viene en aumento. Su funcionamiento es cada vez más complejo lo cual implica una actualización permanente del conocimiento en esta área.


Assuntos
Humanos , Estimulação Cardíaca Artificial , Período Perioperatório , Dispositivos de Terapia de Ressincronização Cardíaca , Radiografia , Desfibriladores Implantáveis , Estimulação Elétrica/métodos , Anestesiologistas
15.
Rev. colomb. cardiol ; 27(5): 420-427, sep.-oct. 2020. tab
Artigo em Inglês | LILACS, COLNAL | ID: biblio-1289252

RESUMO

Abstract Introduction: complications due to cardiac implantable electronic devices have been sparsely studied despite the increased number and complexity of these procedures in a population with multiple comorbidities. Objective: to determine the complication rate and associated risk factors at a reference center in Colombia. Methods: retrospective cohort study, which included patients who had a cardiac electronic device implanted between 2012 and 2015. Clinical records were reviewed to determine if patients developed complications during the year after the procedure, and, if so, which type and which clinical variables could be related to. Results: a total of 897 patients were included, 620 with pacemaker implants and 277 with other devices. The average age was 71.4 years, 63.9% were men, almost all the patients had a chronic disease, and 70% were de novo implants. The global complication rate was 10.9%; Lead displacement (3.6%) and pocket hematoma (3.3%) were the most frequent complications; 7.5% were major complications, and 73.5% occurred in the first month after procedure. The hospitalization rate associated with complications was 9.5%, and the median hospital stay was seven days, with 66.3% of these patients requiring new interventions. The mortality rate was 0.2% Conclusions: complications associated with cardiac implantable electronic devices occur red mainly in the first trimester after the initial intervention, were more frequent in patients under 80 years old, increased according to device complexity, and were not related to with the studied comorbidities.


Resumen Introducción: las complicaciones secundarias al implante de dispositivos cardiacos electrónicos han sido poco estudiadas a pesar del aumento en número y complejidad de estos procedimientos en población con múltiples comorbilidades. Objetivo: determinar la tasa de complicaciones del implante de dispositivos y los factores de riesgo asociados, en un centro de referencia en Colombia. Métodos: estudio de cohorte retrospectiva, que incluyó pacientes a quienes se les implantó dispositivo electrónico cardiaco entre 2012 y 2015. Se revisó la historia clínica para determinar si durante un año posterior al procedimiento, presentaron complicaciones, de qué tipo y con qué variables clínicas podría asociarse. Resultados: se incluyeron 897 pacientes, 620 con implante de marcapaso y 277 otros dispositivos. La edad promedio fue 71.4 años, 63.9% hombres, con múltiples enfermedades crónicas, 70% fueron implantes de novo. Se observó una tasa de complicaciones del 10.9%, la cual varía de acuerdo con el tipo de dispositivo. El desalojo del electrodo (3.6%) y el hematoma del bolsillo (3.3%) fueron las complicaciones más frecuentes, 7.5% fueron complicaciones mayores y 73.5% se presentaron en el primer mes postoperatorio. La tasa de hospitalización asociada a complicación fue 9.5%, mediana de estancia de 7 días, con un 66.3% de los pacientes en requerimiento de reintervención. La tasa de mortalidad fue del 0.2%. Conclusiones: las complicaciones asociadas al implante de dispositivos eléctricos cardiacos se presentaron principalmente en el primer trimestre, fueron más frecuentes en menores de 80 años, aumentaron con la complejidad del dispositivo y no se relacionaron con las comorbilidades estudiadas.


Assuntos
Humanos , Masculino , Idoso , Desfibriladores , Terapia de Ressincronização Cardíaca , Marca-Passo Artificial , Fatores de Risco de Doenças Cardíacas
16.
Rev. argent. cardiol ; 88(5): 429-433, set. 2020. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1251016

RESUMO

RESUMEN Introducción: La prevención de la muerte súbita y el tratamiento de la insuficiencia cardíaca son temas de gran importancia. Para prevenir la muerte súbita y mejorar el pronóstico de la insuficiencia cardíaca se utilizan los cardiodesfibriladores y cardioresincronizadores. Objetivos: Evaluar la cantidad y tipo de dispositivos implantados en nuestro país, así como las características de los pacientes, las complicaciones agudas y las que se presentan en el seguimiento. Material y métodos: Se realizó un estudio observacional, prospectivo, multicéntrico en centros de salud con la capacidad de implantar cardiodesfibriladores y cardioresincronizadores. Se incluyeron pacientes a los que se les realizó implante de estos dispositivos desde enero del 2016 hasta enero de 2017, con un seguimiento de 12 meses. Resultados: Se incluyeron 249 pacientes (edad promedio de 64,8 ± 13,7 años, 73,9% de sexo masculino, 72,1% con Fey < 35%). La etiología subyacente de la miocardiopatía era isquémica en el 39,8%, dilatada 26,7% y chagásica en el 11,2% de los casos. El 58% de los implantes realizados fueron cardiodesfibriladores y el 39%, cardiodesfibriladores asociados con cardioresincronizadores. El 84% de los procedimientos fueron primoimplantes. La indicación más frecuente del implante fue por prevención primaria de muerte súbita (67,9%). La tasa de complicaciones menores fue del 4,4% y no se reportaron complicaciones mayores. Conclusiones: El siguiente registro evidenció una gran proporción de implantes en pacientes con cardiopatía isquémica, la indicación principal fue por prevención primaria de muerte súbita y la tasa de complicaciones fue similar a la reportada internacionalmente.


ABSTRACT Background: Prevention of sudden death and treatment of heart failure are very important topics. Implantable cardioverter-defibrillator and cardiac resynchronization devices are used to prevent sudden death and improve heart failure symptoms and prognosis. Objectives: The aim of this study was to evaluate the number, type of implanted devices, clinical characteristics of the patients and acute and follow-up complications. Methods: An observational, prospective, multicenter study was carried out in healthcare centers with the capacity to implant cardioverter-defibrillator and cardiac resynchronization devices. The study included all patients who underwent implantation of these devices from January 2016 to January 2017, with a 12-month follow-up. Results: A total of 249 patients (73.9% men) with mean age of 64.8±13.7 years, and 72.1% with ejection fraction <35%, were included in the study. The underlying cardiomyopathy etiology was ischemic in 39.8% of cases, dilated in 26.7% and chagasic in 11.2%. Fifty-eight percent of implants were implantable cardioverter-defibrillators and 39% were cardioverter-defibrillators associated with cardiac resynchronization devices. In 84% of cases, procedures were first implants. The most frequent indica-tion of implantation was for primary prevention of sudden death (67.9%). Minor complication rate was 4.4% and no major complications were reported. Conclusions: The present registry evidenced a large proportion of cardioverter-defibrillator and cardiac resynchronization implants in patients with ischemic heart disease. The main indication was for primary prevention of sudden death and the complication rate was similar to that reported internationally.

17.
Rev. colomb. cardiol ; 27(4): 232-239, jul.-ago. 2020. tab, graf
Artigo em Espanhol | LILACS, COLNAL | ID: biblio-1289221

RESUMO

Resumen Objetivo: medir el impacto de la terapia de resincronización cardiaca en términos de variables ecocardiográficas en pacientes de países latinoamericanos. Método: se realizó un estudio prospectivo, multicéntrico, intervencionista, en el que los pacientes elegibles fueron llevados, por primera vez, a implante de un dispositivo de resincronización cardiaca. El objetivo primario fue valorar los cambios del tamaño y la función del ventrículo izquierdo por medio de un ecocardiograma previo al implante del dispositivo y en el sexto mes. Los objetivos secundarios evaluados fueron hospitalizaciones, cambios en la clase funcional, mortalidad, calidad de vida y un score compuesto clínico basado en estos factores de evaluación global del paciente. Resultados: para cumplir el objetivo primario se analizaron datos de 75 sujetos. La edad promedio fue de 63,7 años; 21.3% fueron mujeres y 30.7% tuvieron cardiopatía isquémica. Al sexto mes de seguimiento las mediciones de volumen de fin de diástole y sístole del ventrículo izquierdo disminuyeron en promedio 37.6 ml y 37.8 ml, respectivamente. La fracción de eyección del ventrículo izquierdo en promedio se incrementó un 11%. El puntaje compuesto clínico mostró mejoría en el 86.4% de los pacientes en el sexto mes postimplante del resincronizador. Conclusiones: se observó remodelado inverso del ventrículo izquierdo y mejoría en el estado clínico de los pacientes con insuficiencia cardiaca y disfunción sistólica del ventrículo izquierdo que recibieron terapia de resincronización cardiaca en el ámbito de la práctica clínica de rutina.


Abstract Objective: To measure the impact of cardiac resynchronisation therapy in terms of cardiac ultrasound variables in patients from Latin-American countries. Method: A prospective, multicentre, interventionist study was conducted, in which the eligible patients were those that had a cardiac resynchronisation device implanted for the first time. The primary objective was to assess the changes in size and left ventricular function by means of a cardiac ultrasound carried out prior to implanting the device and in the sixth month. The secondary objectives evaluated were hospital admissions, change in functional class, mortality, quality of life, and an overall assessment of the patient using a combined clinical score based on these factors. Results: A total of 75 subjects were analysed in order to complete the primary objective. The mean age was 63.7 years; 21.3% were female, and 30.7% had ischaemic heart disease. At the sixth month, the left ventricular end-diastolic and systolic volume decreased by a mean of 37.6 ml and 37.8 ml, respectively. The left ventricular ejection fraction increased by a mean of 11%. The combined clinical score showed an improvement in 86.4% of the patients in the sixth month after the implantation of the synchronisation device. Conclusions: A reverse remodelling of the left ventricle was observed, as well as an improvement in the clinical stage of patients with heart failure and left ventricular systolic dysfunction that received cardiac resynchronisation treatment in the setting of routine clinical practice.


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Terapêutica , Ecocardiografia , Mortalidade
18.
Rev. colomb. cardiol ; 27(4): 270-275, jul.-ago. 2020. graf
Artigo em Espanhol | LILACS, COLNAL | ID: biblio-1289225

RESUMO

Resumen Objetivo: diseñar y desarrollar un aplicativo móvil, innovador y útil que facilite el registro, la extracción y el análisis de datos en cardiología, y que permita la realización de investigaciones de alta calidad en pacientes con insuficiencia cardiaca llevados a terapia de resincronización. Metodología: se utilizó el marco de trabajo Scrum, ya que ofrece características de agilidad necesarias para la definición de requerimientos en un entorno colaborativo y en equipo; se realizaron entregas parciales de un producto final, lo cual facilitó la rapidez en el desarrollo de la aplicación. CardioResyncApp es una aplicación móvil que estará disponible en las dos plataformas móviles más importantes: App Store y Google Play. Resultado: se diseñó y desarrolló un aplicativo móvil, innovador, especializado en la recolección de datos para estudios de investigación en cardiología referentes a insuficiencia cardiaca y terapia de resincronización. Conclusiones: CardioResyncApp es un aplicativo móvil, ágil, fácil de usar, que revolucionará la recolección de datos en Colombia, para investigación en cardiología. No tendrá limitaciones geográficas para la recolección de datos ya que se encuentra disponible en las plataformas móviles más populares, como IOS y Android, lo cual facilitará la realización de estudios multicéntricos en Colombia, aproximándonos a la realidad de la enfermedad en las diversas poblaciones a pesar de las variaciones sociodemográficas.


Abstract Objective: The aim of this study is to design and develop a new and useful mobile application that facilitates the recording, extraction and analysis of data in cardiology, and can help in the carrying out of high quality research on patients with heart failure receiving resynchronisation therapy. Methodology: Scrum development technology was used, since it offers the dynamic features necessary to define the requirements in collaborative and team environment. Partial deliveries will be made of a final product, which will help to speed up the development of the application. CardioResyncApp is a mobile phone application that will be available on the two most important mobile platforms: App Store and Google Play. Results: A novel mobile application was designed and developed to collect data for research studies in cardiology as regards heart failure and resynchronisation therapy. Conclusions: CardioResyncApp is a dynamic, easy to use, mobile application what will revolutionise data collection in Colombia for cardiology research. It will have no geographic limitations for the collection of data, since it is available on the most popular mobile platforms such as IOS and Android, which will help in the conducting of multicentre studies in Colombia, and approaching the reality of the disease in the various populations despite the sociodemographic variations.


Assuntos
Software , Coleta de Dados , Registros Eletrônicos de Saúde , Pesquisa , Cardiologia , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca
19.
Acta méd. colomb ; 44(4): 38-41, Oct.-Dec. 2019. tab, graf
Artigo em Inglês | LILACS, COLNAL | ID: biblio-1124059

RESUMO

Abstract There is a high prevalence of cardiac stimulation therapy complications; however, they are frequently forgotten by medical personnel. Cardiomyopathy secondary to biventricular dyssynchrony due to high right ventricular stimulation is a frequent cause of heart failure, increasing the risk of death and hospitalization and decreasing the quality of life of patients with pacemakers. We present a case of a patient who developed heart failure. The most common causes of left ventricular dysfunction were ruled out, and it was determined to be secondary to pacemaker-induced cardiomyopathy. The patient's device was changed to biventricular cardiac resynchronization therapy, with an adequate clinical response. We highlight the importance of looking for complications related to right ventricular stimulation devices in patients with heart failure, and of considering a change to biventricular stimulation within the treatment plan. (Acta Med Colomb 2019; 44. DOI:https://doi.org/10.36104/amc.2019.1300).


Resumen Las complicaciones derivadas de la terapia de estimulación cardiaca tienen alta prevalencia, sin embargo, a menudo son olvidadas por el personal médico. La miocardiopatía secundaria a la disincronía biventricular por la alta carga de estimulación ventricular derecha es una causa frecuente de falla cardiaca, aumentando el riesgo de muerte, hospitalizaciones y disminuyendo la calidad de vida en los pacientes con marcapasos. Presentamos un caso de una paciente que desarrolló falla cardiaca, se descartaron las causas más comunes de disfunción ventricular izquierda y se consideró secundaria a miocardiopatía inducida por marcapasos, se le realizó cambio de dispositivo por terapia de resincronización cardiaca biventricular con adecuada respuesta clínica. Resaltamos la importancia de buscar en los pacientes con falla cardiaca complicaciones asociadas a dispositivos de estimulación ventricular derecha y considerar dentro del tratamiento el cambio a estimulación biventricular. (Acta Med Colomb 2019; 44. DOI:https://doi.org/10.36104/amc.2019.1300).


Assuntos
Feminino , Pessoa de Meia-Idade , Cardiomiopatias , Pacientes , Qualidade de Vida , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca
20.
Rev. argent. cardiol ; 87(6): 434-440, nov. 2019. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1250902

RESUMO

RESUMEN Introducción: La terapia de resincronización cardíaca presenta una tasa de un 25%-30% de pacientes "no respondedores". La resincronización endocárdica, en la que el catéter del ventrículo izquierdo se implanta en el endocardio, sería una alternativa para estos pacientes, aunque su evolución a largo plazo no ha sido investigada. Objetivos: Evaluación hemodinámica no invasiva a largo plazo de la resincronización endocárdica en respondedores clínicos. Métodos: Se incluyeron pacientes implantados según los criterios para resincronización, usando la técnica Jurdham, con más de 6 meses desde el implante. Todos eran respondedores clínicos. La respuesta hemodinámica se evaluó con un analizador de la función cardíaca, que mide los intervalos sistólicos (períodos preeyectivo y eyectivo) del ventrículo izquierdo y calcula automáticamente un índice de función sistólica y estimar la fracción de eyección (Systocor mod ÍS100). Para determinar la eficacia mecánica de la TRCe se comparó la función cardíaca durante el modo biventricular con el bloqueo completo de la rama izquierda, espontáneo o por estimulación única del ventrículo derecho; los pacientes fueron sus propios controles. Se promediaron al menos 20 latidos en cada modo de estimulación y se consideraron solo los cambios >1% con valor p < 0,01 como clínicamente relevantes y estadísticamente significativos. Resultados: Se incluyeron 17 pacientes, con mediana de seguimiento de 43 meses, rango 9 a 78 meses. La resincronización endocárdica, en comparación con la activación ventricular con BCRI, demostró que todos los pacientes acortaron el período preeyectivo en un promedio de 31 ms (15%), indicativo de disminución de la disincronía interventricular causada por el BCRI. En todos aumentó el índice de función sistólica en 0,3 (23%) y la FE en el 8,3%. En 12/17 (71%) aumentó el período eyectivo en promedio 8,7 mseg (2,9%), lo que sugiere un aumento del volumen sistólico. En todos los cambios el valor de p fue menor de 0,01. Conclusiones: La TRCe ofrece mejoría hemodinámica significativa a largo plazo, detectada por intervalos sistólicos.


ABSTRACT Background: Cardiac resynchronization therapy has 25% to 30% rate of "non-responder" patients. Endocardial cardiac resynchronization therapy (eCRT), in which the left ventricular catheter is implanted in the endocardium, would be an alternative for these patients; however, its long-term outcome has not been investigated. Objectives: The aim of this study was the long-term non-invasive hemodynamic evaluation of eCRT in clinical responders. Methods: Patients implanted according to the criteria for resynchronization, using the Jurdham technique, with more than 6 months after the implant, were included in the study. All were clinical responders. The hemodynamic response was evaluated with a cardiac function analyzer, which measures the left ventricular systolic intervals (preejection and ejection periods) and automatically calculates an index of systolic function and estimates the ejection fraction (Systocor mod ÍS100). To assess the mechanical efficacy of eCRT, the cardiac function during biventricular mode was compared with left bundle branch block (LBBB), either spontaneous or by single stimulation of the right ventricle, with patients as their own controls. At least 20 beats were averaged in each stimulation mode and only changes >1% with p <0.01 were considered as clinically relevant and statistically significant. Results: Seventeen patients were included, with a median follow-up of 43 months, (9 to 78 months). Endocardial resynchronization, compared with LBBB ventricular activation, showed that all patients shortened the preejection period by an average of 31 ms (15%), indicative of decreased interventricular dyssynchrony caused by LBBB. In all patients, systolic function index increased by 0.3 (23%) and the EF by 8.3%. In 12/17 of cases (71%) the ejective period increased on average 8.7 ms (2.9%), suggesting an increase in systolic volume. In all changes p was <0.01. Conclusions: Endocardial resynchronization therapy offers significant long-term hemodynamic improvement, detected by systolic intervals.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...