Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.094
Filtrar
1.
J Audiol Otol ; 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38973324

RESUMO

Background and Objectives: : Masseter vestibular evoked myogenic potential (mVEMP) is a newly developed tool which is used to assess the vestibulo-trigeminal neural and saccular functioning pathways. Recently, this test was added to a full test battery for evaluating the brainstem of people with neurological disorders and other vestibular diseases. For any test to qualify as a standard test, the test must have high reliability across all testing windows. Hence, the present study focused on validating the reliability of mVEMP in a large population. Subjects and Methods: : The study included 50 healthy participants with normal hearing. All the participants were tested using mVEMP and underwent retest within a month after the initial test. All parameters (latencies, peak-to-peak amplitude, asymmetric ratio) were observed for both sessions. To determine the statistically significant differences between and across the sessions, non-parametric tests such as Mann-Whitney U and Wilcoxon signed-rank tests were used. Results: : The test-retest reliability of all parameters were observed. The reliability was fair-to-good for P11 and N21 latencies. The other parameters showed less significance. There were no significant differences in sex and ear comparisons between and across the sessions. Conclusions: : Our study demonstrated that the mVEMP is a reliable test which can be used to assess peripheral vestibular system dysfunction and neurological conditions.

2.
EJNMMI Phys ; 11(1): 54, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38951352

RESUMO

BACKGROUND: Several factors may decrease the accuracy of quantitative PET myocardial perfusion imaging (MPI). It is therefore essential to ensure that myocardial blood flow (MBF) values are reproducible and accurate, and to design systematic protocols to achieve this. Until now, no systematic phantom protocols have been available to assess the technical factors affecting measurement accuracy and reproducibility in MPI. MATERIALS AND METHODS: We implemented a standard measurement protocol, which applies a flow phantom in order to compare image-derived flow values with respect to a ground truth flow value with [15O]H2O MPI performed on both a Discovery MI (DMI-20, GE Healthcare) and a Biograph Vision 600 (Vision-600, Siemens Healthineers) system. Both systems have automatic [15O]H2O radio water generators (Hidex Oy) individually installed, allowing us to also study the differences occurring due to two different bolus delivery systems. To investigate the technical factors contributing to the modelled flow values, we extracted the [15O]H2O bolus profiles, the flow values from the kinetic modeling (Qin and Qout), and finally calculated their differences between test-retest measurements on both systems. RESULTS: The measurements performed on the DMI-20 system produced Qin and Qout values corresponging to each other as well as to the reference flow value across all test-retest measurements. The repeatability differences on DMI-20 were 2.1% ± 2.6% and 3.3% ± 4.1% for Qin and Qout, respectively. On Vision-600 they were 10% ± 8.4% and 11% ± 10% for Qin and Qout, respectively. The measurements performed on the Vision-600 system showed more variation between Qin and Qout values across test-retest measurements and exceeded 15% difference in 7/24 of the measurements. CONCLUSIONS: A preliminary protocol for measuring the accuracy and reproducibility of flow values in [15O]H2O MPI between digital PET/CT systems was assessed. The test-retest reproducibility falls below 15% in majority of the measurements conducted between two individual injector systems and two digital PET/CT systems. This study highlights the importance of implementing a standardized bolus injection and delivery protocol and importance of assessing technical factors affecting flow value reproducibility, which should be carefully investigated in a multi-center setting.

3.
HNO ; 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38958758

RESUMO

BACKGROUND: To date, there is no consensus on how to standardize the assessment of ototoxicity in serial measurements. For the diagnosis of damage to the cochlear amplifier, measurement methods are required that have the highest possible test-retest reliability and validity for detecting persistent damage. Estimated distortion-product thresholds (LEDPT) based on short-pulse distortion-product otoacoustic emission (DPOAE) level maps use individually optimal DPOAE stimulus levels and allow reliable quantitative estimation of cochlea-related hearing loss. MATERIALS AND METHODS: Hearing thresholds were estimated objectively using LEDPT and subjectively using modified Békésy tracking audiometry (LTA). Recordings were performed seven times within three months at 14 frequencies (f2 = 1-14 kHz) in 20 ears (PTA4 (0.5-4 kHz) < 20 dB HL). Reconstruction of the DPOAE growth behavior as a function of the stimulus levels L1, L2 was performed on the basis of 21 DPOAE amplitudes. A numerical fit of a nonlinear mathematical function to the three-dimensional DPOAE growth function yielded LEDPT for each stimulus frequency. For the combined analysis, probability distributions of hearing thresholds (LTA, LEDPT), DPOAE levels (LDP), and combinations thereof were determined. RESULTS: LTA and LEDPT each exhibited a test-retest reliability with a median of absolute differences (AD) of 3.2 dB and 3.3 dB, respectively. Combining LEDPT, LDP, and LTA into a single parameter yielded a significantly smaller median AD of 2.0 dB. CONCLUSION: It is expected that an analysis paradigm based on a combination of LEDPT, suprathreshold LDP, and fine-structure-reduced LTA would achieve higher test performance (sensitivity and specificity), allowing reliable detection of pathological or regenerative changes in the outer hair cells.

4.
J Appl Stat ; 51(8): 1609-1617, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38863801

RESUMO

In this paper, we consider the estimation of intracluster correlation for ordinal data. We focus on pure-tone audiometry hearing threshold data, where thresholds are measured in 5 decibel increments. We estimate the intracluster correlation for tests from iPhone-based hearing assessment applications as a measure of test/retest reliability. We present a method to estimate the intracluster correlation using mixed effects cumulative logistic and probit models, which assume the outcome data are ordinal. This contrasts with using a mixed effects linear model which assumes that the outcome data are continuous. In simulation studies, we show that using a mixed effects linear model to estimate the intracluster correlation for ordinal data results in a negative finite sample bias, while using mixed effects cumulative logistic or probit models reduces this bias. The estimated intracluster correlation for the iPhone-based hearing assessment application is higher when using the mixed effects cumulative logistic and probit models compared to using a mixed effects linear model. When data are ordinal, using mixed effects cumulative logistic or probit models reduces the bias of intracluster correlation estimates relative to using a mixed effects linear model.

5.
Mult Scler Relat Disord ; 88: 105731, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38924934

RESUMO

BACKGROUND: Reliability parameters of clinical measures should be sufficient in order to adequately monitor disease course and evaluate treatment in patients with Multiple Sclerosis (MS). The aim of this study was to assess the reliability of the Timed 25-Foot-Walk (T25FW) in patients with MS. METHODS: MS patients performed the T25FW twice with approximately one year in between. After the second measurement, they answered an anchor question using a three-point Likert scale. Taking the non-normal distribution of the T25FW into account, intraclass correlation coefficient (ICCagreement), standard error of the mean (SEMagreement) and smallest detectable change (SDC) were computed. RESULTS: 118 MS patients (76.3 % females, mean age 48.2 years) were included. Of these patients, 73 reported no change on the anchor question. They completed the T25FW at baseline in 4.7s (IQR 4.3-5.4s, n = 72) and at follow-up in 4.9s (IQR 4.3-5.9s, n = 73). The ICCagreement was 0.895, the SEMagreement was 0.037. The SDC was higher for higher mean T25FW and can be computed for each mean T25FW by 0.23*mean T25FW. CONCLUSION: Overall, in patients with MS, the T25FW has a sufficient reliability as measured with the ICC, however the SDC of the T25FW increased when patients perform worse on the T25FW (i.e. have a lower walking speed). Because this test is often used in MS patients with limited walking ability, these findings are important to keep in mind when interpreting the re-test scores of the T25FW.

6.
Sensors (Basel) ; 24(12)2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38931483

RESUMO

The Orthelligent Pro sensor is a practicable, portable measuring instrument. This study assessed the validity and reliability of this sensor in measuring single-leg countermovement jumps. Fifty healthy athletic adults participated in two measurement sessions a week apart in time. They performed single-leg countermovement jumps on the force plate while wearing the Orthelligent Pro sensor on their lower leg. During the first measurement session, Tester 1 invited the participants to make three single-leg countermovement jumps; subsequently, Tester 2 did the same. For assessing the sensor's intratester reliability, Tester 1 again invited the participants to make three single-leg countermovement jumps during the second measurement session. The sensor's validity was assessed by using the force plate results as the gold standard. To determinate the agreement between two measurements, Bland-Altman plots were created. The intertester reliability (ICC = 0.99; 0.97) and intratester reliability (ICC = 0.96; 0.82) were both excellent. The validity calculated (i) on the basis of the mean value of three jumps and (ii) on the basis of the maximum value of three jumps was very high, but it showed a systematic error. Taking this error into account, physiotherapists can use the Orthelligent Pro sensor as a valid and reliable instrument for measuring the jump height of countermovement jumps.


Assuntos
Perna (Membro) , Humanos , Masculino , Adulto , Feminino , Reprodutibilidade dos Testes , Perna (Membro)/fisiologia , Adulto Jovem , Atletas , Fenômenos Biomecânicos/fisiologia , Movimento/fisiologia
7.
EJNMMI Res ; 14(1): 58, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38922458

RESUMO

BACKGROUND: O-(2-[18F]fluoroethyl)-L-tyrosine positron emission tomography ([18F]FET PET) scanning is used in routine clinical management and evaluation of gliomas with a recommended 4 h prior fasting. Knowledge of test-retest variation of [18F]FET PET imaging uptake metrics and the impact of accidental protein intake can be critical for interpretation. The aim of this study was to investigate the repeatability of [18F]FET-PET metrics and to assess the impact of protein-intake prior to [18F]FET PET scanning of gliomas. RESULTS: Test-retest variability in the non-protein group was good with absolute (and relative) upper and lower limits of agreement of + 0.15 and - 0.13 (+ 9.7% and - 9.0%) for mean tumour-to-background ratio (TBRmean), + 0.43 and - 0.28 (+ 19.6% and - 11.8%) for maximal tumour-to-background ratio (TBRmax), and + 2.14 cm3 and - 1.53 ml (+ 219.8% and - 57.3%) for biological tumour volume (BTV). Variation was lower for uptake ratios than for BTV. Protein intake was associated with a 27% increase in the total sum of plasma concentration of the L-type amino acid transporter 1 (LAT1) relevant amino acids and with decreased standardized uptake value (SUV) in both healthy appearing background brain tissue (mean SUV - 25%) and in tumour (maximal SUV - 14%). Oral intake of 24 g of protein 1 h prior to injection of tracer tended to increase variability, but the effects on derived tumour metrics TBRmean and TBRmax were only borderline significant, and changes generally within the variability observed in the group with no protein intake. CONCLUSION: The test-retest repeatability was found to be good, and better for TBRmax and TBRmean than BTV, with the methodological limitation that tumour growth may have influenced results. Oral intake of 24 g of protein one hour before a [18F]FET PET scan decreases uptake of [18F]FET in both tumour and in healthy appearing brain, with no clinically significant difference on the most commonly used tumour metrics.

8.
Brain Sci ; 14(6)2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38928619

RESUMO

Both chronic and recurrent spinal pain alter sensorimotor integration (SMI), which is demonstrated using complex neurophysiological techniques. Currently, there is no patient-reported outcome measure that documents and/or assesses SMI in populations with spinal problems. The purpose of this study was to develop the Sensory-Motor Dysfunction Questionnaire (SMD-Q) and assess its test-retest reliability and internal consistency in individuals with recurrent spinal pain. The SMD-Q was developed based on the existing literature on motor control disturbances associated with disordered SMI. The initial SMD-Q drafts underwent review by two separate panels of subject matter experts and a focus group with subclinical spine pain. Their suggestions were incorporated into the questionnaire prior to reliability testing. The questionnaire was administered twice at a seven-day interval using QualtricsTM. A total of 20 participants (14 females and 6 males; 20.95 ± 2.46 years of age) completed the study. Quadratic weighted kappa (Kw) was used to assess test-retest reliability and Cronbach's alpha (α) was used to assess internal consistency. Four items had a Kw < 0.40, seven had a 0.40 < Kw < 0.75, and one had a Kw > 0.75 (excellent agreement), with excellent internal consistency (α > 0.90). The pilot SMD-Q appears to reliably measure altered SMI, suggesting that revisions and testing with a larger sample are worth pursuing.

9.
Artigo em Inglês | MEDLINE | ID: mdl-38928933

RESUMO

Reliable and valid data on physical activity (PA) and sedentary behavior (SB) are needed for implementing evidence-based interventions and policies. Monitoring of these behaviors is based on PA questionnaires (PAQs) and device-based measurements, but their comparability is challenging. The present study aimed to investigate the test-retest reliability and concurrent validity of Finnish versions of the widely used PAQs (IPAQ-SF, EHIS-PAQ, GPAQ, Eurobarometer) and to compare their data with accelerometer data. This study is based on the Finnish data of the European Union Physical Activity and Sport Monitoring project (EUPASMOS). Participants (n = 62 adults, 62% women) answered the PAQs twice, one week apart, and wore an accelerometer for these seven consecutive days. Intraclass correlations, Spearman's rank correlations, t-tests, and Cohen's kappa with bootstrap confidence intervals were used to analyze the data. The PAQs had typically moderate-to-good test-retest reliability (ICC 0.22-0.78), GPAQ, EHIS-PAQ, and Eurobarometer showing the highest reliability. The PAQs correlated with each other when assessing sitting and vigorous PA (R = 0.70-0.97) and had a fair-to-substantial agreement when analyzing adherence to the PA recommendations (74-97%, Cohen's kappa 0.25-0.73). All the PAQs had a poor criterion validity against the accelerometry data. The Finnish versions of the PAQs are moderately reliable and valid for assessing PA, adherence to PA recommendations and sitting among adult participants. However, the poor criterion validity against accelerometer data indicates that PAQs assess different aspects of PA constructs compared to accelerometry.


Assuntos
Acelerometria , Exercício Físico , Comportamento Sedentário , Autorrelato , Humanos , Finlândia , Feminino , Masculino , Adulto , Reprodutibilidade dos Testes , Pessoa de Meia-Idade , Inquéritos e Questionários , Adulto Jovem , Idoso
10.
Neuroimage ; 297: 120688, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38878916

RESUMO

The human brain is organized as a complex, hierarchical network. However, the structural covariance patterns among brain regions and the underlying biological substrates of such covariance networks remain to be clarified. The present study proposed a novel individualized structural covariance network termed voxel-based texture similarity networks (vTSNs) based on 76 refined voxel-based textural features derived from structural magnetic resonance images. Validated in three independent longitudinal healthy cohorts (40, 23, and 60 healthy participants, respectively) with two common brain atlases, we found that the vTSN could robustly resolve inter-subject variability with high test-retest reliability. In contrast to the regional-based texture similarity networks (rTSNs) that calculate radiomic features based on region-of-interest information, vTSNs had higher inter- and intra-subject variability ratios and test-retest reliability in connectivity strength and network topological properties. Moreover, the Spearman correlation indicated a stronger association of the gene expression similarity network (GESN) with vTSNs than with rTSNs (vTSN: r = 0.600, rTSN: r = 0.433, z = 39.784, P < 0.001). Hierarchical clustering identified 3 vTSN subnets with differential association patterns with 13 coexpression modules, 16 neurotransmitters, 7 electrophysiology, 4 metabolism, and 2 large-scale structural and 4 functional organization maps. Moreover, these subnets had unique biological hierarchical organization from the subcortex-limbic system to the ventral neocortex and then to the dorsal neocortex. Based on 424 unrelated, qualified healthy subjects from the Human Connectome Project, we found that vTSNs could sensitively represent sex differences, especially for connections in the subcortex-limbic system and between the subcortex-limbic system and the ventral neocortex. Moreover, a multivariate variance component model revealed that vTSNs could explain a significant proportion of inter-subject behavioral variance in cognition (80.0 %) and motor functions (63.4 %). Finally, using 494 healthy adults (aged 19-80 years old) from the Southwest University Adult Lifespan Dataset, the Spearman correlation identified a significant association between aging and vTSN strength, especially within the subcortex-limbic system and between the subcortex-limbic system and the dorsal neocortex. In summary, our proposed vTSN is robust in uncovering individual variability and neurobiological brain processes, which can serve as biologically plausible measures for linking biological processes and human behavior.

11.
J Nurs Meas ; 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38834352

RESUMO

Background and Purpose: Stability testing, conducted using a test-retest protocol, measures an instrument's reliability by evaluating the consistency of participant responses to survey questions with repeated testing within a short interval. No studies have measured the stability of the Verran Professional Governance Scale© (VPGS). The purpose of this study was to evaluate the test-retest reliability of the VPGS. Methods: Volunteers from a parent study using the VPGS were sent a link to a retest version of the survey 14 days after taking the initial survey with a reminder email sent 5 days after the first request. Item-level and subscale comparisons were made between participants' initial and retest responses using intraclass correlation coefficients (ICCs) applying a two-way random-effects model. Results: VPGS subscales had ICC scores of 0.71 for decision-making, 0.73 for collateral relationships, and 0.86 for professional obligation. Conclusions: Findings suggest that the VPGS demonstrates test-retest reliability. Future research should evaluate the instrument's responsiveness.

12.
PeerJ ; 12: e17403, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38827299

RESUMO

Background: Effective rehabilitation of upper limb musculoskeletal disorders requires multimodal assessment to guide clinicians' decision-making. Furthermore, a comprehensive assessment must include reliable tests. Nevertheless, the interrelationship among various upper limb tests remains unclear. This study aimed to evaluate the reliability of easily applicable upper extremity assessments, including absolute values and asymmetries of muscle mechanical properties, pressure pain threshold, active range of motion, maximal isometric strength, and manual dexterity. A secondary aim was to explore correlations between different assessment procedures to determine their interrelationship. Methods: Thirty healthy subjects participated in two experimental sessions with 1 week between sessions. Measurements involved using a digital myotonometer, algometer, inclinometer, dynamometer, and the Nine-Hole Peg test. Intraclass correlation coefficients, standard error of the mean, and minimum detectable change were calculated as reliability indicators. Pearson's correlation was used to assess the interrelationship between tests. Results: For the absolute values of the dominant and nondominant sides, reliability was 'good' to 'excellent' for muscle mechanical properties, pressure pain thresholds, active range of motion, maximal isometric strength, and manual dexterity. Similarly, the reliability for asymmetries ranged from 'moderate' to 'excellent' across the same parameters. Faster performance in the second session was consistently found for the Nine-Hole Peg test. No systematic inter-session errors were identified for the values of the asymmetries. No significant correlations were found between tests, indicating test independence. Conclusion: These findings indicate that the sensorimotor battery of tests is reliable, while monitoring asymmetry changes may offer a more conservative approach to effectively tracking recovery of upper extremity injuries.


Assuntos
Antebraço , Mãos , Amplitude de Movimento Articular , Humanos , Masculino , Feminino , Reprodutibilidade dos Testes , Adulto , Amplitude de Movimento Articular/fisiologia , Mãos/fisiologia , Antebraço/fisiologia , Adulto Jovem , Voluntários Saudáveis , Músculo Esquelético/fisiologia , Limiar da Dor/fisiologia
13.
Neuroimage ; 296: 120673, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38851550

RESUMO

Morphological features sourced from structural magnetic resonance imaging can be used to infer human brain connectivity. Although integrating different morphological features may theoretically be beneficial for obtaining more precise morphological connectivity networks (MCNs), the empirical evidence to support this supposition is scarce. Moreover, the incorporation of different morphological features remains an open question. In this study, we proposed a method to construct cortical MCNs based on multiple morphological features. Specifically, we adopted a multi-dimensional kernel density estimation algorithm to fit regional joint probability distributions (PDs) from different combinations of four morphological features, and estimated inter-regional similarity in the joint PDs via Jensen-Shannon divergence. We evaluated the method by comparing the resultant MCNs with those built based on different single morphological features in terms of topological organization, test-retest reliability, biological plausibility, and behavioral and cognitive relevance. We found that, compared to MCNs built based on different single morphological features, MCNs derived from multiple morphological features displayed less segregated, but more integrated network architecture and different hubs, had higher test-retest reliability, encompassed larger proportions of inter-hemispheric edges and edges between brain regions within the same cytoarchitectonic class, and explained more inter-individual variance in behavior and cognition. These findings were largely reproducible when different brain atlases were used for cortical parcellation. Further analysis of macaque MCNs revealed weak, but significant correlations with axonal connectivity from tract-tracing, independent of the number of morphological features. Altogether, this paper proposes a new method for integrating different morphological features, which will be beneficial for constructing MCNs.


Assuntos
Córtex Cerebral , Imageamento por Ressonância Magnética , Rede Nervosa , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Feminino , Córtex Cerebral/diagnóstico por imagem , Córtex Cerebral/anatomia & histologia , Adulto , Rede Nervosa/diagnóstico por imagem , Rede Nervosa/anatomia & histologia , Conectoma/métodos , Algoritmos , Adulto Jovem , Processamento de Imagem Assistida por Computador/métodos , Mapeamento Encefálico/métodos
14.
Scand J Psychol ; 2024 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-38824419

RESUMO

OBJECTIVE: To perform a psychometric evaluation of a Norwegian version of the Berlin Misophonia Questionnaire Revised (BMQ-R-NOR). DESIGN: Participants completed online versions of the self-report questionnaire BMQ-R-NOR on two occasions and MQ-NOR on one occasion. Convergent validity was assessed through Spearman's correlation between BMQ-R-NOR and MQ-NOR. Internal consistency was evaluated with McDonald's omega and Cronbach's alpha. Test-retest reliability was evaluated using Cohen's weighted kappa and intraclass correlation. STUDY SAMPLE: 82 participants with self-reported misophonia took part in the study at T1, and 53 of these participated at T2. However, only 41 of them were included in the test-retest analyses due to 12 participants being in treatment between T1 and T2. RESULTS: Subscales from the BMQ-R-NOR and MQ-NOR were significantly positively correlated, indicating evidence of convergent validity (rs = 0.22*-0.74**). The BMQ-R-NOR showed overall good internal consistency (omega = 0.72-0.93; alpha = 0.70-0.93) and satisfactory test-retest reliability (ICC = 0.35-0.92). CONCLUSION: The psychometric properties of the BMQ-R-NOR are considered satisfactory. However, it is advised to exercise caution when using it until further comprehensive validation studies are conducted to ensure robustness and reliability in clinical practice.

15.
Behav Res Methods ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844601

RESUMO

Rapid adaptation to sudden changes in the environment is a hallmark of flexible human behaviour. Many computational, neuroimaging, and even clinical investigations studying this cognitive process have relied on a behavioural paradigm known as the predictive-inference task. However, the psychometric quality of this task has never been examined, leaving unanswered whether it is indeed suited to capture behavioural variation on a within- and between-subject level. Using a large-scale test-retest design (T1: N = 330; T2: N = 219), we assessed the internal (internal consistency) and temporal (test-retest reliability) stability of the task's most used measures. We show that the main measures capturing flexible belief and behavioural adaptation yield good internal consistency and overall satisfying test-retest reliability. However, some more complex markers of flexible behaviour show lower psychometric quality. Our findings have implications for the large corpus of previous studies using this task and provide clear guidance as to which measures should and should not be used in future studies.

16.
Appl Neuropsychol Adult ; : 1-6, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38917223

RESUMO

INTRODUCTION: There is still a requirement for concise, practical scales that can be readily incorporated into everyday schedules and predict the likelihood of dementia onset in individuals without dementia. This study aimed to assess the reliability of the ANU-ADRI (Australian National University Alzheimer's Disease Risk Index)-Short Form in Turkish geriatric patients. METHODS: This methodological study involved 339 elderly patients attending the geriatric outpatient clinic for various reasons. The known-group validity and divergent validity were assessed. The ANU-ADRI was administered during the baseline test and again within one week for retest purposes. Alongside the ANU-ADRI, all participants underwent a comprehensive geriatric assessment, including Activities of Daily Living (ADL), mobility assessment (Performance-Oriented Mobility Assessment (POMA) and Timed Up and Go Test), nutritional assessment (Mini Nutritional Assessment (MNA)), and global cognition evaluation (Mini-Mental State Examination (MMSE)). RESULTS: The scale demonstrated satisfactory linguistic validity. A correlation was observed between the mean scores of the ANU-ADRI test and retest (r = 0.997, p < 0.001). Additionally, there existed a moderate negative linear association between the ANU-ADRI and MMSE scores (r = -0.310, p < 0.001), POMA (r = -0.406, p < 0.001), Basic ADL (r = -0.359, p < 0.001), and Instrumental ADL (r = -0.294, p < 0.001). Moreover, a moderate positive linear association was found between the ANU-ADRI and the Timed Up and Go Test duration (r = 0.538, p < 0.001). CONCLUSION: The ANU-ADRI-Short Form was proved as a valuable tool for clinical practice, facilitating the assessment of Alzheimer's disease risk within the Turkish geriatric population.

17.
Cogn Affect Behav Neurosci ; 24(4): 740-754, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38849641

RESUMO

The Iowa Gambling Task (IGT) is used to assess decision-making in clinical populations. The original IGT does not disambiguate reward and punishment learning; however, an adaptation of the task, the "play-or-pass" IGT, was developed to better distinguish between reward and punishment learning. We evaluated the test-retest reliability of measures of reward and punishment learning from the play-or-pass IGT and examined associations with self-reported measures of reward/punishment sensitivity and internalizing symptoms. Participants completed the task across two sessions, and we calculated mean-level differences and rank-order stability of behavioral measures across the two sessions using traditional scoring, involving session-wide choice proportions, and computational modeling, involving estimates of different aspects of trial-level learning. Measures using both approaches were reliable; however, computational modeling provided more insights regarding between-session changes in performance, and how performance related to self-reported measures of reward/punishment sensitivity and internalizing symptoms. Our results show promise in using the play-or-pass IGT to assess decision-making; however, further work is still necessary to validate the play-or-pass IGT.


Assuntos
Tomada de Decisões , Jogo de Azar , Testes Neuropsicológicos , Punição , Recompensa , Humanos , Masculino , Feminino , Adulto Jovem , Tomada de Decisões/fisiologia , Adulto , Reprodutibilidade dos Testes , Testes Neuropsicológicos/normas , Adolescente , Aprendizagem/fisiologia
18.
BMC Health Serv Res ; 24(1): 644, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38769529

RESUMO

BACKGROUND: This paper aims to instigate discussion and publication of methodologies applied to enhance quality management through comprehensive scientific reports. It provides a detailed description of the design, implementation, and results of the quality control program employed in the SMESH study. METHODS: Cross-sectional, multicenter, national study designed to assess the prevalence of human papillomavirus in sex workers and in men who have sex with men (MSM). Respondent-driven sampling recruitment was used. An online system was developed for the study and checkpoints were defined for data entry. The system checked the quality of biological samples and performed a retest with part of the sample. RESULTS: A total of 1.598 participants (442 sex workers and 1.156 MSM) were included. Fifty-four health professionals were trained for face-to-face data collection. The retest showed Kappa values ranging between 0.3030 and 0.7663. CONCLUSION: The retest data were mostly classified as indicating a strong association. The data generated by the checkpoints showed the successful implementation of the quality control program.


Assuntos
Infecções por Papillomavirus , Humanos , Estudos Transversais , Masculino , Infecções por Papillomavirus/prevenção & controle , Profissionais do Sexo/estatística & dados numéricos , Homossexualidade Masculina/estatística & dados numéricos , Adulto , Feminino , Controle de Qualidade , Prevalência
19.
Health Qual Life Outcomes ; 22(1): 40, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38816717

RESUMO

PURPOSE: The Quality of Life-Aged Care Consumers (QOL-ACC), a valid preference-based instrument, has been rolled out in Australia as part of the National Quality Indicator (QI) program since April 2023 to monitor and benchmark the quality of life of aged care recipients. As the QOL-ACC is being used to collect quality of life data longitudinally as one of the key aged care QI indicators, it is imperative to establish the reliability of the QOL-ACC in aged care settings. Therefore, we aimed to assess the reliability of the QOL-ACC and compare its performance with the EQ-5D-5L. METHODS: Home care recipients completed a survey including the QOL-ACC, EQ-5D-5L and two global items for health and quality of life at baseline (T1) and 2 weeks later (T2). Using T1 and T2 data, the Gwet's AC2 and intra-class correlation coefficient (ICC) were estimated for the dimension levels and overall scores agreements respectively. The standard error of measurement (SEM) and the smallest detectable change (SDC) were also calculated. Sensitivity analyses were conducted for respondents who did not change their response to global item of quality of life and health between T1 and T2. RESULTS: Of the 83 respondents who completed T1 and T2 surveys, 78 respondents (mean ± SD age, 73.6 ± 5.3 years; 56.4% females) reported either no or one level change in their health and/or quality of life between T1 and T2. Gwet's AC2 ranged from 0.46 to 0.63 for the QOL-ACC dimensions which were comparable to the EQ-5D-5L dimensions (Gwet's AC2 ranged from 0.52 to 0.77). The ICC for the QOL-ACC (0.85; 95% CI, 0.77-0.90) was comparable to the EQ-5D-5L (0.83; 95% CI, 0.74-0.88). The SEM for the QOL-ACC (0.08) was slightly smaller than for the EQ-5D-5L (0.11). The SDC for the QOL-ACC and the EQ-5D-5L for individual subjects were 0.22 and 0.30 respectively. Sensitivity analyses stratified by quality of life and health status confirmed the base case results. CONCLUSIONS: The QOL-ACC demonstrated a good test-retest reliability similar to the EQ-5D-5L, supporting its repeated use in aged care settings. Further studies will provide evidence of responsiveness of the QOL-ACC to aged care-specific interventions in aged care settings.


Assuntos
Serviços de Assistência Domiciliar , Qualidade de Vida , Humanos , Qualidade de Vida/psicologia , Feminino , Masculino , Idoso , Reprodutibilidade dos Testes , Austrália , Inquéritos e Questionários , Idoso de 80 Anos ou mais , Serviços de Assistência Domiciliar/normas , Psicometria/instrumentação
20.
Clin Neurophysiol ; 163: 244-254, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38820994

RESUMO

OBJECTIVE: Diseases affecting sensorimotor function impair physical independence. Reliable functional clinical biomarkers allowing early diagnosis or targeting treatment and rehabilitation could reduce this burden. Magnetoencephalography (MEG) non-invasively measures brain rhythms such as the somatomotor 'rolandic' rhythm which shows intermittent high-amplitude beta (14-30 Hz) 'events' that predict behavior across tasks and species and are altered by sensorimotor neurological diseases. METHODS: We assessed test-retest stability, a prerequisite for biomarkers, of spontaneous sensorimotor aperiodic (1/f) signal and beta events in 50 healthy human controls across two MEG sessions using the intraclass correlation coefficient (ICC). Beta events were determined using an amplitude-thresholding approach on a narrow-band filtered amplitude envelope obtained using Morlet wavelet decomposition. RESULTS: Resting sensorimotor characteristics showed good to excellent test-retest stability. Aperiodic component (ICC 0.77-0.88) and beta event amplitude (ICC 0.74-0.82) were very stable, whereas beta event duration was more variable (ICC 0.55-0.7). 2-3 minute recordings were sufficient to obtain stable results. Analysis automatization was successful in 86%. CONCLUSIONS: Sensorimotor beta phenotype is a stable feature of an individual's resting brain activity even for short recordings easily measured in patients. SIGNIFICANCE: Spontaneous sensorimotor beta phenotype has potential as a clinical biomarker of sensorimotor system integrity.


Assuntos
Ritmo beta , Magnetoencefalografia , Humanos , Masculino , Feminino , Adulto , Magnetoencefalografia/métodos , Magnetoencefalografia/normas , Ritmo beta/fisiologia , Reprodutibilidade dos Testes , Córtex Sensório-Motor/fisiologia , Adulto Jovem , Descanso/fisiologia , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...