Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 782
Filtrar
1.
J Cardiothorac Surg ; 19(1): 416, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38961402

RESUMO

BACKGROUND: The occurrence of type II endoleaks after endovascular repair of aortic aneurysm has gradually gained increasing attention. We present a case of a patient with an expanding aneurysm after thoracic endovascular aortic repair (TEVAR) for a type II endoleak, in which successful direct ligations of the intercostal artery were performed using a sac incision without cardiopulmonary bypass (CPB) or graft replacement. CASE PRESENTATION: A 62-year-old male patient, previously treated with TEVAR for a descending thoracic aortic aneurysm, presented with ongoing chest discomfort. Based on the diagnosis of a growing aneurysm and type II endoleak, the patient was prepared for CPB and aortic cross-clamping, as a precautions against the possibility of a type I endoleak. A longitudinal opening of the thoracic aortic aneurysm sac was performed following left thoracotomy. Visual confirmation identified the T5 level intercostal artery as the source of the endoleak, and after confirming the absence of a type I endoleak, multiple ligations were applied to the intercostal artery. Follow-up computed tomography confirmed the absence of endoleaks or sac growth. CONCLUSION: In a case involving TEVAR for a thoracic aortic aneurysm, open suture ligations were used to treat type II endoleaks without having to resort to CPB, resulting in successful outcomes.


Assuntos
Aneurisma da Aorta Torácica , Endoleak , Procedimentos Endovasculares , Humanos , Masculino , Endoleak/cirurgia , Endoleak/etiologia , Pessoa de Meia-Idade , Aneurisma da Aorta Torácica/cirurgia , Procedimentos Endovasculares/métodos , Implante de Prótese Vascular/métodos , Implante de Prótese Vascular/efeitos adversos , Tomografia Computadorizada por Raios X , Aorta Torácica/cirurgia , Ligadura , Correção Endovascular de Aneurisma
3.
Ann Biomed Eng ; 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38836979

RESUMO

Contrary to most vessels, the ascending thoracic aorta (ATA) not only distends but also elongates in the axial direction. The purpose of this study is to investigate the biomechanical behavior of the ascending thoracic aorta (ATA) in response to dynamic axial stretching during the cardiac cycle. In addition, the implications of neglecting this dynamic axial stretching when estimating the constitutive model parameters of the ATA are investigated. The investigations were performed through in silico simulations by assuming a Gasser-Ogden-Holzapfel (GOH) constitutive model representative of ATA tissue material. The GOH model parameters were obtained from biaxial tests performed on four human ATA tissues in a previous study. Pressure-diameter curves were simulated as synthetic data to assess the effect of neglecting dynamic axial stretching on estimating constitutive model parameters. Our findings reveal a significant increase in axial stress (~ 16%) and stored strain energy (~ 18%) in the vessel when dynamic axial stretching is considered, as opposed to assuming a fixed axial stretch. All but one artery showed increased volume compliance while considering a dynamic axial stretching condition. Furthermore, we observe a notable difference in the estimated constitutive model parameters when dynamic axial stretching of the ATA is neglected, compared to the ground truth model parameters. These results underscore the critical importance of accounting for axial deformations when conducting in vivo biomechanical characterization of the ascending thoracic aorta.

4.
Eur J Cardiothorac Surg ; 65(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38837348

RESUMO

OBJECTIVES: To assess the accuracy of a deep learning-based algorithm for fully automated detection of thoracic aortic calcifications in chest computed tomography (CT) with a focus on the aortic clamping zone. METHODS: We retrospectively included 100 chest CT scans from 91 patients who were examined on second- or third-generation dual-source scanners. Subsamples comprised 47 scans with an electrocardiogram-gated aortic angiography and 53 unenhanced scans. A deep learning model performed aortic landmark detection and aorta segmentation to derive 8 vessel segments. Associated calcifications were detected and their volumes measured using a mean-based density thresholding. Algorithm parameters (calcium cluster size threshold, aortic mask dilatation) were varied to determine optimal performance for the upper ascending aorta that encompasses the aortic clamping zone. A binary visual rating served as a reference. Standard estimates of diagnostic accuracy and inter-rater agreement using Cohen's Kappa were calculated. RESULTS: Thoracic aortic calcifications were observed in 74% of patients with a prevalence of 27-70% by aorta segment. Using different parameter combinations, the algorithm provided binary ratings for all scans and segments. The best performing parameter combination for the presence of calcifications in the aortic clamping zone yielded a sensitivity of 93% and a specificity of 82%, with an area under the receiver operating characteristic curve of 0.874. Using these parameters, the inter-rater agreement ranged from κ 0.66 to 0.92 per segment. CONCLUSIONS: Fully automated segmental detection of thoracic aortic calcifications in chest CT performs with high accuracy. This includes the critical preoperative assessment of the aortic clamping zone.


Assuntos
Aorta Torácica , Doenças da Aorta , Aprendizado Profundo , Tomografia Computadorizada por Raios X , Calcificação Vascular , Humanos , Aorta Torácica/diagnóstico por imagem , Estudos Retrospectivos , Feminino , Masculino , Calcificação Vascular/diagnóstico por imagem , Idoso , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Doenças da Aorta/diagnóstico por imagem , Algoritmos , Idoso de 80 Anos ou mais
5.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38733578

RESUMO

OBJECTIVES: The goal of this multicentre retrospective cohort study was to evaluate technical success and early and late outcomes of thoracic endovascular repair (TEVAR) with grafts deployed upside down through antegrade access, to treat thoracic aortic diseases. METHODS: Antegrade TEVAR operations performed between January 2010 and December 2021 were collected and analysed. Both elective and urgent procedures were included. Exclusion criteria were endografts deployed in previous or concomitant surgical or endovascular repairs. RESULTS: Fourteen patients were enrolled; 13 were males (94%) with a mean age of 71 years (interquartile range 62; 78). Five patients underwent urgent procedures (2 ruptured aortas and 3 symptomatic patients). Indications for treatment were 8 (57%) aneurysms/pseudoaneurysms, 3 (21%) dissections and 3 (21%) penetrating aortic ulcers. Technical success was achieved in all procedures. Early mortality occurred in 4 (28%) cases, all urgent procedures. Median follow-up was 13 months (interquartile range 1; 44). Late deaths occurred in 2 (20%) patients, both operated on in elective settings. The first died at 19 months of aortic-related reintervention; the second died at 34 months of a non-aortic-related cause. Two patients (14%) underwent aortic-related reinterventions for late type I endoleak. The survival rate of those having the elective procedures was 100%, 84% and 67% at 12, 24 and 36 months, respectively. Freedom from reintervention was 92%, 56% and 56% at 12, 24 and 36 months, respectively. CONCLUSIONS: Antegrade TEVAR can seldom be considered an alternative when traditional retrograde approach is not feasible. Despite good technical success and few access-site complications, this study demonstrates high rates of late type I endoleak and aortic-related reinterventions.


Assuntos
Aorta Torácica , Doenças da Aorta , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Procedimentos Endovasculares/métodos , Idoso , Feminino , Estudos Retrospectivos , Aorta Torácica/cirurgia , Pessoa de Meia-Idade , Doenças da Aorta/cirurgia , Implante de Prótese Vascular/métodos , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/mortalidade , Complicações Pós-Operatórias/epidemiologia , Prótese Vascular , Correção Endovascular de Aneurisma
6.
Hellenic J Cardiol ; 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38729346

RESUMO

OBJECTIVE: To evaluate the clinical characteristics, imaging findings, treatment, and prognosis of patients with type A acute aortic syndrome (AAS-A) presenting with shock. To assess the impact of surgery on this patient population. METHODS: The study included 521 patients with A-AAS enrolled in the Spanish Registry of Acute Aortic Syndrome (RESA-III) from January 2018 to December 2019. The RESA-III is a prospective, multicenter registry that contains AAS data from 30 tertiary-care hospitals. Patients were classified into two groups according to their clinical presentation, with or without shock. Shock was defined as persistent systolic blood pressure <80 mmHg despite adequate volume resuscitation. RESULTS: 97 (18.6%) patients with A-AAS presented with shock. Clinical presentation with syncope was much more common in the Shock group (45.4% vs 10.1%, p = 0.001). Patients in the Shock group had more complications at diagnosis and before surgery: cardiac tamponade (36.2% vs 9%, p < 0.001), acute renal failure (28.9% vs 18.2%, p = 0.018), and need for orotracheal intubation (40% vs 9.1%, p < 0.001). There were no significant differences in aortic regurgitation (51.6% vs 46.7%, p = 0.396) between groups. In-hospital mortality was higher among patients with shock (48.5% vs 27.4%, p < 0.001). Surgery was associated with a significant mortality reduction both in patients with and without shock. Surgery had an independent protective effect on mortality (OR 0.03, 95% CI (0.00-0.32)). CONCLUSION: Patients with AAS-A admitted with shock have a heavily increased risk of mortality. Syncope and pericardial effusion at diagnosis are strongly associated with shock. Surgery was independently associated with a mortality reduction in patients with AAS-A and shock.

7.
J Endovasc Ther ; : 15266028241256817, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38817015

RESUMO

BACKGROUND: Thrombotic material in the non-aneurysmatic and non-atherosclerotic aorta is a rare entity without any recommended standard treatment so far. We present a successful treatment strategy for patients who do not fit into any of the common approaches. CASE REPORT: A free-floating thrombus in the descending aorta was found as source of embolism in an 82-year-old female patient with lower limb ischemia. After initial heparinization of the patient without relevant reduction of the thrombotic mass, the thrombus was removed using an interdisciplinary approach. Under echocardiographic guidance to locate the thrombus, the AngioVac device, usually licensed to remove floating thrombi from the venous system, was used off-label to remove the thrombus by a transfemoral approach. To avoid rebuilding of a new thrombus, the attachment point with an exulcerated plaque in the descending aorta was covered by a stent graft via the same femoral access. The patient did not experience any further embolic events, and the postoperative course was uncomplicated. CONCLUSION: Patients with uncommon aortic diseases, such as the reported free-floating thrombus, should be treated by an individualized, interdisciplinary approach. Besides the recommended treatment options, there are other uncommon approaches that might offer an alternative in complex cases. CLINICAL IMPACT: Evidence is rare for the treatment of a free-floating thrombus in the descending aorta and the treatment strategy remains discussed controversially. We present a rather uncommon approach of successful off-label treatment for patients who do not fit into any of the common approaches (operative, endovascular, or conservative treatment based on patient's comorbidities). The AngioVac System has already been successfully used off-label in the arterial system but not in the above presented way of treating a free-floating thrombus in a patient with high embolization risk and treatment-limiting comorbidities.

8.
Hypertens Res ; 47(7): 1897-1907, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38664509

RESUMO

Artificial light at night (ALAN) disrupts 24-h variability of blood pressure, but the molecular mechanisms underlying these effects are unknown. Therefore, we analysed the daily variability of pulse pressure, the maximum value of acceleration rate of aortic pressure (dP/dt(max)) measured by telemetry and protein expression in the thoracic aorta of normotensive male rats exposed to ALAN (1-2 lx) for 3 weeks. Daily, 24-h variability of pulse pressure and dP/dt(max) was observed during a regular light/dark regimen with higher values during the dark compared to the light phase of the day. ALAN suppressed 24-h variability and enhanced ultradian (<12-h) periods of pulse pressure and dP/dt(max) in duration-dependent manners. From beat-to-beat blood pressure variability, ALAN decreased low-frequency bands (a sympathetic marker) and had minimal effects on high-frequency bands. At the molecular level, ALAN decreased angiotensin II receptor type 1 expression and reduced 24-h variability. ALAN caused the appearance of 12-h oscillations in transforming growth factor ß1 and fibulin 4. Expression of sarco/endoplasmic reticulum Ca2+-ATPase type 2 was increased in the middle of the light and dark phase of the day, and ALAN did not affect its daily and 12-h variability. In conclusion, ALAN suppressed 24-h variability of pulse pressure and dP/dt(max), decreased the power of low-frequency bands and differentially affected the expression of specific proteins in the rat thoracic aorta. Suppressed 24-h oscillations by ALAN underline the pulsatility of individual endocrine axes with different periods, disrupting the cardiovascular control of central blood pressure.


Assuntos
Aorta Torácica , Pressão Sanguínea , Ritmo Circadiano , Animais , Masculino , Aorta Torácica/metabolismo , Pressão Sanguínea/fisiologia , Ratos , Ritmo Circadiano/fisiologia , Fator de Crescimento Transformador beta1/metabolismo , Receptor Tipo 1 de Angiotensina/metabolismo , Luz , Proteínas da Matriz Extracelular/metabolismo , Ratos Sprague-Dawley , Proteínas de Ligação ao Cálcio/metabolismo
9.
Morphologie ; 108(362): 100779, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38608628

RESUMO

BACKGROUND: One of the most recent hormones to be identified and isolated is irisin, extracted from mouse skeletal muscle in 2012. Irisin has been proven to alter blood pressure, which has an impact on blood vessels, enhance endothelial functions, and prevent injury to endothelial cells. The current study aimed to study the effect of irisin on the ultrastructure of the rat thoracic aorta using the transmission electron microscope (TEM). MATERIALS AND METHODS: Twenty female rats were recruited for this study and divided into a control group (non-injected), and four experimental groups (injected groups) each consisting of 4 rats. The experimental groups were injected intraperitoneally with different doses of irisin (250ng/mL, 500ng/mL, 1000ng/mL, and 2000ng/mL) twice a week for 4weeks. Then, the descending thoracic aorta of all experimental rats were resected and proceeded with imaging. RESULTS: The results of this study showed a change in the thickness of the tunica intima, internal elastic lamina, elastic lamellae, and external elastic lamina concerning increasing injected irisin concentration. While there was a significant increase in the thickness of tunica media (P<0.0001) and smooth muscle cells (P<0.05). Also, the results showed a significant increase in the number of elastic lamellae in the tunica media (P<0.0001). CONCLUSION: Irisin had a major impact on the elasticity of the rat thoracic aorta wall, suggesting that it influences the growth factors of the wall and activates smooth muscle cells in addition to endothelial cells.

10.
Artigo em Inglês | MEDLINE | ID: mdl-38685313
11.
Am J Cardiol ; 210: 1-7, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38682707

RESUMO

The effect of an initial surgical approach (in comparison with initial medical therapy) in acute type A intramural hematoma remains insufficiently explored. We designed a pooled analysis of Kaplan-Meier-derived individual patient data from studies with follow-up for overall survival (all-cause death). Restricted mean survival time was calculated to evaluate lifetime gain or loss. The Risk of Bias in Non-Randomized Studies of Interventions tool (ROBINS-I) was used to assess risk of bias. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) was applied to assess certainty of evidence. Eight studies met our eligibility criteria, including a total of 654 patients (311 patients treated with surgery and 343 patients treated with medical therapy alone). All the studies were non-randomized and observational. The median follow-up was 4.6 years (interquartile range 1.0 to 7.7). Patients who underwent surgery had a significantly lower risk of mortality compared with patients receiving medical therapy alone (hazard ratio 0.51, 95% confidence interval 0.35 to 0.74, p <0.001). The restricted mean survival time was overall 1.1 years greater with surgery compared with medical therapy, and this difference was statistically significant (p <0.001), which means that surgery is associated with lifetime gain. The overall risk of bias (ROBINS-I) was considered moderate-to-serious and the certainty of evidence (GRADE) was deemed to be low. In conclusion, in the overall follow-up, surgery as the initial approach was associated with better late survival and lifetime gain in comparison with medical therapy alone in the setting of acute type A aortic intramural hematoma; however, high-quality randomized trials are warranted to establish the efficacy of the surgical strategy.


Assuntos
Hematoma , Humanos , Hematoma/cirurgia , Taxa de Sobrevida/tendências , Procedimentos Cirúrgicos Vasculares/métodos , Fatores de Tempo , Doenças da Aorta/cirurgia , Doenças da Aorta/mortalidade , Resultado do Tratamento , Hematoma Intramural Aórtico
12.
Medicina (Kaunas) ; 60(4)2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38674307

RESUMO

Background and objectives: The relationship between cerebral perfusion and new postoperative ischemic stroke in obese patients is not well defined. The aim of this study was to investigate the association between selective bilateral anterograde cerebral perfusion and new postoperative ischemic stroke in obese patients with emergency surgery for acute type A aortic dissection. Materials and methods: A total of 292 patients with emergency surgery for acute type A aortic dissection were included in this study. Patients with hemorrhagic stroke or ischemic stroke with severe neurological dysfunction at admission that were not candidates for surgery; patients who died in the first 48 h after intensive care admission and patients with incomplete medical records were excluded. Results: The mean age was 59.42 ± 10.68 years and the mean Euroscore was 9.12 ± 1.63. Obesity was present in 76.4%, the incidence of new postoperative ischemic stroke was 27.5%, and the postoperative mortality rate was 26.7%. The mean cardiopulmonary bypass time was 206.81 ± 75.48 min, the aortic cross-clamp time was 118.2 ± 46.42 min, and 90% of cases required cerebral perfusion. The mean cerebral perfusion time was 30.8 ± 24.41 min. Obese patients had a higher frequency of in-hospital death (p = 0.009), smoking (p = 0.036), hypertension (p = 0.023), left common carotid artery dissection (p < 0.001), right common carotid artery dissection (p = 0.029), femoral artery cannulation (p = 0.026), aortic root replacement (p = 0.009), aortic valve replacement (p = 0.005) and early reintervention for bleeding (p = 0.004). Using logistic regression, selective bilateral anterograde cerebral perfusion over 40 min in obese patients was independently associated with new postoperative ischemic stroke (OR = 2.35; 95%CI = 1.36-4.86; p = 0.021). Conclusions: A patient-tailored strategy for cerebral perfusion should be considered in obese patients, considering the high atheromatous burden of the supra-aortic vessels in these patients and the potential risk of atheromatous embolization associated with this technique.


Assuntos
Dissecção Aórtica , AVC Isquêmico , Obesidade , Complicações Pós-Operatórias , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Dissecção Aórtica/cirurgia , Dissecção Aórtica/complicações , Dissecção Aórtica/fisiopatologia , Obesidade/complicações , Idoso , AVC Isquêmico/etiologia , AVC Isquêmico/complicações , Complicações Pós-Operatórias/etiologia , Circulação Cerebrovascular/fisiologia , Estudos Retrospectivos , Fatores de Risco , Perfusão/métodos , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/fisiopatologia
14.
Braz J Cardiovasc Surg ; 39(3): e20230160, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38629955

RESUMO

OBJECTIVE: To evaluate the occurrence of aortic dilatation and its associated predictors with coarctation of the aorta (CoA) in infants using multi-slice computed tomography (MSCT). METHODS: The clinical data of 47 infantile patients with CoA diagnosed by MSCT and 28 infantile patients with simple ventricular septal defect were analyzed retrospectively. Aortic diameters were measured at six different levels, and aortic sizes were compared by z score. The coarctation site-diaphragm ratio was used to describe the degree of narrowing. Relevant clinical data were collated and analyzed. RESULTS: The dilation rate and z score of the ascending aorta in the severe CoA group were significantly higher than those in the mild CoA group (11 [52.38%] vs. 21 [80.77%], P=0.038 and 2.00 ± 0.48 vs. 2.36 ± 0.43, P=0.010). Pearson's correlation analysis found that the z score of the ascending aorta was negatively correlated with the coarctation site-diaphragm ratio value (r=-0.410, P=0.004). A logistic retrospective analysis found that an increased degree of coarctation was an independent predictor of aortic dilatation (adjusted odds ratio 0.002; 95% confidence interval 0.00-0.819; P=0.043). The z score of the ascending aorta in the severe CoA group was significantly higher than that in the ventricular septal defect group (P<0.05). CONCLUSION: Most infants with CoA can also have significant dilatation of the ascending aorta, and the degree of this dilatation is related to the degree of coarctation. Assessment of aortic diameter and related malformations by MSCT can predict the risk of aortic dilatation in infants with CoA.


Assuntos
Coartação Aórtica , Comunicação Interventricular , Lactente , Humanos , Angiografia por Tomografia Computadorizada , Dilatação , Estudos Retrospectivos , Coartação Aórtica/diagnóstico por imagem
15.
Eur J Nucl Med Mol Imaging ; 51(8): 2260-2270, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38456972

RESUMO

INTRODUCTION: Non-invasive detection of pathological changes in thoracic aortic disease remains an unmet clinical need particularly for patients with congenital heart disease. Positron emission tomography combined with magnetic resonance imaging (PET-MRI) could provide a valuable low-radiation method of aortic surveillance in high-risk groups. Quantification of aortic microcalcification activity using sodium [18F]fluoride holds promise in the assessment of thoracic aortopathies. We sought to evaluate aortic sodium [18F]fluoride uptake in PET-MRI using three methods of attenuation correction compared to positron emission tomography computed tomography (PET-CT) in patients with bicuspid aortic valve, METHODS: Thirty asymptomatic patients under surveillance for bicuspid aortic valve disease underwent sodium [18F]fluoride PET-CT and PET-MRI of the ascending thoracic aorta during a single visit. PET-MRI data were reconstructed using three iterations of attenuation correction (Dixon, radial gradient recalled echo with two [RadialVIBE-2] or four [RadialVIBE-4] tissue segmentation). Images were qualitatively and quantitatively analysed for aortic sodium [18F]fluoride uptake on PET-CT and PET-MRI. RESULTS: Aortic sodium [18F]fluoride uptake on PET-MRI was visually comparable with PET-CT using each reconstruction and total aortic standardised uptake values on PET-CT strongly correlated with each PET-MRI attenuation correction method (Dixon R = 0.70; RadialVIBE-2 R = 0.63; RadialVIBE-4 R = 0.64; p < 0.001 for all). Breathing related artefact between soft tissue and lung were detected using Dixon and RadialVIBE-4 but not RadialVIBE-2 reconstructions, with the presence of this artefact adjacent to the atria leading to variations in blood pool activity estimates. Consequently, quantitative agreements between radiotracer activity on PET-CT and PET-MRI were most consistent with RadialVIBE-2. CONCLUSION: Ascending aortic microcalcification analysis in PET-MRI is feasible with comparable findings to PET-CT. RadialVIBE-2 tissue attenuation correction correlates best with the reference standard of PET-CT and is less susceptible to artefact. There remain challenges in segmenting tissue types in PET-MRI reconstructions, and improved attenuation correction methods are required.


Assuntos
Aorta Torácica , Imageamento por Ressonância Magnética , Imagem Multimodal , Humanos , Masculino , Feminino , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Aorta Torácica/diagnóstico por imagem , Adulto , Calcinose/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Idoso , Valva Aórtica/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos
17.
Biomed Phys Eng Express ; 10(3)2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38437732

RESUMO

Thoracic aorta calcium (TAC) can be assessed from cardiac computed tomography (CT) studies to improve cardiovascular risk prediction. The aim of this study was to develop a fully automatic system to detect TAC and to evaluate its performance for classifying the patients into four TAC risk categories. The method started by segmenting the thoracic aorta, combining three UNets trained with axial, sagittal and coronal CT images. Afterwards, the surrounding lesion candidates were classified using three combined convolutional neural networks (CNNs) trained with orthogonal patches. Image datasets included 1190 non-enhanced ECG-gated cardiac CT studies from a cohort of cardiovascular patients (age 57 ± 9 years, 80% men, 65% TAC > 0). In the test set (N = 119), the combination of UNets was able to successfully segment the thoracic aorta with a mean volume difference of 0.3 ± 11.7 ml (<6%) and a median Dice coefficient of 0.947. The combined CNNs accurately classified the lesion candidates and 87% of the patients (N = 104) were accurately placed in their corresponding risk categories (Kappa = 0.826, ICC = 0.9915). TAC measurement can be estimated automatically from cardiac CT images using UNets to isolate the thoracic aorta and CNNs to classify calcified lesions.


Assuntos
Aorta Torácica , Aprendizado Profundo , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Cálcio , Tomografia Computadorizada por Raios X/métodos , Eletrocardiografia
18.
Vascular ; : 17085381241238041, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38452485

RESUMO

OBJECTIVES: Repairing thoracic aortic aneurysms with endovascular aortic repair (TEVAR) is a safe and minimally invasive method with low morbidity and short postoperative recovery. We developed a novel method to treat descending thoracic aortic aneurysms using a mini-thoracotomy approach in complex patients with difficult access. METHODS: A 56-year-old male patient presented with a 3-day history of chest pain. His past surgical history included infrarenal aortic ligation and right axillobifemoral bypass. Thoracic computed tomography angiography (CTA) revealed a saccular aortic aneurysmal dilatation at zone 2 measuring 4.4 × 4 cm. Owing to his surgical history, vascular access through the femoral and iliac arteries or abdominal aorta was impossible. We developed a new technique using a left posterolateral mini-thoracotomy approach to gain vascular access and perform TEVAR, avoiding the need for an open thoracotomy repair. RESULTS AND CONCLUSIONS: Thoracic CTA performed before discharge revealed complete aneurysmal exclusion and no endoleaks. Postoperative follow-up CTA (6 months and annually thereafter) revealed no aneurysm formation or aortic restenosis. The femoral artery, followed by the iliac artery, is the traditional access route for TEVAR. Left posterolateral mini-thoracotomy may be required as an alternative access in complex patients.

19.
J Am Coll Cardiol ; 83(12): 1136-1146, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38508846

RESUMO

BACKGROUND: Aortic aneurysm is common in patients with coarctation of aorta (COA), but it is unclear whether the risk of aortic aneurysms is due to COA or related to the presence of other risk factors such as bicuspid aortic valve (BAV) and hypertension. OBJECTIVES: The purpose of this study was to assess the relationship among COA, BAV, and thoracic aortic aneurysms. METHODS: A total of 867 patients with COA (COA group) were matched 1:1:1 to 867 patients with isolated BAV (BAV group) and 867 patients without structural heart disease (SHD) (no-SHD group). The COA group was further subdivided into a COA+BAV subgroup (n = 304 [35%]), and COA with tricuspid aortic valve (TAV) (COA+TAV subgroup [n = 563 (65%)]). Aortic dimensions were assessed at baseline and at 3, 5, and 7 years. RESULTS: Compared with the no-SHD group, the COA+BAV subgroup had larger aortic root diameter (37 mm [Q1-Q3: 30-43 mm] vs 32 mm [Q1-Q3: 27-35 mm]; P < 0.001) and mid ascending aorta dimeter (34 mm [Q1-Q3: 29-40 mm] vs 28 mm [Q1-Q3: 24-31 mm]; P = 0.008). Similarly, the BAV group had larger aortic root diameter (37 mm [Q1-Q3: 30-42 mm] vs 32 mm [Q1-Q3: 27-35 mm]; P < 0.001), and mid ascending aorta dimeter (35 mm [Q1-Q3: 30-40 mm] vs 28 mm [Q1-Q3: 24-31 mm]; P < 0.001). Compared with the COA+TAV subgroup, the COA+BAV subgroup and BAV group were associated with larger aortic root and mid ascending aorta diameter at baseline and follow-up. The risk of acute aortic complications was low in all groups. CONCLUSIONS: These findings suggest that BAV (and not COA) was associated with ascending thoracic aorta dimensions, and that patients with COA+TAV were not at a greater risk of developing ascending aortic aneurysms as compared with patients without SHD.


Assuntos
Aneurisma da Aorta Ascendente , Aneurisma Aórtico , Coartação Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Humanos , Valva Aórtica/diagnóstico por imagem , Coartação Aórtica/complicações , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/epidemiologia , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/epidemiologia , Aneurisma Aórtico/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...