Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J Radiol Prot ; 43(3)2023 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-37678246

RESUMO

Wearing lead aprons and thyroid collars for long periods of time has a subjective component: to balance the effective dose reduction with the effort of carrying a heavy load. Occupational radiation exposure has decreased dramatically in the last century within the health care system. During the same period the use of lead aprons and thyroid collars has also gone up. Therefore, a question that may be raised is: how safe is safe enough? In order to promote stakeholder involvement, the aim of the present study was to investigate staff's experience of discomforts associated with wearing lead aprons and thyroid collars for long periods of time, and also to investigate staff's willingness to tolerate personal dose equivalent (expressed as radiation dose) and the corresponding increase in future cancer risk to avoid wearing these protective tools. A questionnaire was developed and given to staff working in operating or angiography rooms at Skaraborg Hospital in Sweden. The results from the 245 respondents showed that 51% experienced bothersome warmth, 36% experienced fatigue and 26% experienced ache or pain that they believed was associated with wearing lead aprons. One third of the respondents would tolerate a personal dose equivalent of 1 mSv per year to avoid wearing lead aprons, but only a fifth would tolerate the corresponding increase in future cancer risk (from 43% to 43.2%). In conclusion, discomforts associated with wearing lead aprons and thyroid collars for long periods of time are common for the staff using them. At the same time, only a minority of the staff would tolerate a small increase in future cancer risk to avoid wearing them. The present study gives an example of stakeholder involvement and points at the difficulties in making reasonable decisions about the use of these protective tools.


Assuntos
Neoplasias , Lesões por Radiação , Humanos , Glândula Tireoide , Tomada de Decisões , Hospitais
2.
J Am Dent Assoc ; 154(9): 826-835.e2, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37530694

RESUMO

BACKGROUND: The American Academy of Oral and Maxillofacial Radiology established an ad hoc committee to draft evidence-based recommendations and clinical guidance for the application of patient contact shielding during dentomaxillofacial imaging. TYPES OF STUDIES REVIEWED: The committee reviewed monographs and reports from radiation protection organizations and studies that reported radiation dose to gonads, breasts, and thyroid gland from dentomaxillofacial imaging. RESULTS: Considering the absence of radiation-induced heritable effects in humans and the negligible dose to the gonads and fetus from dentomaxillofacial imaging, the committee recommends discontinuing shielding of the gonads, pelvic structures, and fetuses during all dentomaxillofacial radiographic imaging procedures. On the basis of radiation doses from contemporaneous maxillofacial imaging, the committee considered that the risks from thyroid cancer are negligible and recommends that thyroid shielding not be used during intraoral, panoramic, cephalometric, and cone-beam computed tomographic imaging. PRACTICAL IMPLICATIONS: This position statement informs and educates the reader on evolving radiation protection practices and provides simple, unequivocal guidance to dental personnel to implement these guidelines. State and local authorities should be contacted to update regulations to reflect these recommendations.


Assuntos
Radiografia Dentária , Radiologia , Humanos , Doses de Radiação , Radiografia Dentária/métodos , Radiografia Panorâmica/métodos , Tomografia Computadorizada de Feixe Cônico/métodos
3.
Cardiovasc Intervent Radiol ; 46(7): 943-952, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37280331

RESUMO

PURPOSE: We utilized an anthropomorphic model made with a human skull to determine how different personal protective equipment influence operator intracranial radiation absorbed dose. MATERIALS AND METHODS: A custom anthropomorphic phantom made with a human skull coated with polyurethane rubber, mimicking superficial tissues, and was mounted onto a plastic thorax. To simulate scatter, an acrylic plastic scatter phantom was placed onto the fluoroscopic table with a 1.5 mm lead apron on top. Two Radcal radiation detectors were utilized; one inside of the skull and a second outside. Fluoroscopic exposures were performed with and without radiation protective equipment in AP, 45-degree RAO, and 45-degree LAO projections. RESULTS: The skull and soft tissues reduce intracranial radiation by 76% when compared to radiation outside the skull. LAO (308.95 µSv/min) and RAO projections (96.47µSv/min) result in significantly higher radiation exposure to the primary operator when compared to an AP projection (54 µSv/min). All tested radiation protection equipment demonstrated various reduction in intracranial radiation when compared to no protection. The hood (68% reduction in AP, 91% LAO, and 43% in RAO), full cover (53% reduction in AP, 76% in LAO, and 54% in RAO), and open top with ear coverage (43% reduction in AP, 77% reduction in LAO, and 22% in RAO) demonstrated the most reduction in intracranial radiation when compared to the control. CONCLUSION: All tested equipment provided various degrees of additional intracranial protection. The skull and soft tissues attenuate a portion of intracranial radiation.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Proteção Radiológica , Humanos , Doses de Radiação , Exposição à Radiação/prevenção & controle , Imagens de Fantasmas , Fluoroscopia , Exposição Ocupacional/prevenção & controle
4.
Rev. chil. cardiol ; 39(2): 105-113, ago. 2020. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1138523

RESUMO

ANTECEDENTES: Las unidades de Cardiología intervencional han evidenciado un número creciente de procedimientos, cada vez más variados y complejos, lo cual podría eventualmente generar daños a los profesionales ocupacionalmente expuestos a radiaciones ionizantes (POEs) de no contar con los adecuados elementos de radioprotección y un uso correcto de ellos. OBJETIVO: Caracterizar la disponibilidad y utilización de los elementos de radioprotección y dosimetría de unidades de cardiología intervencionista de centros Sudamericanos. MATERIAL Y MÉTODOS: Se realizó una encuesta autoaplicada a 139 POEs, de ambos sexos de 7 países, a través de una plataforma on-line, se les consultó sobre características demográficas, dosimétricas y de radioprotección. RESULTADOS: Los elementos de radioprotección más tradicionales; delantales y cuellos plomados se utilizaron un 99,5 % y 98,4 % respectivamente, aquellos elementos más recientes como gafas, gorros y paños plomados solo alcanzaron un 36,8 %, 6,8 % y 34,2%, de utilización respectivamente, en cuanto a la utilización de los dosímetros, solo un 7,9 % lo hace apegado a las normas de la Organización Internacional de Energía Atómica (OIEA). CONCLUSIÓN: Se constató en la muestra analizada una falta de elementos de radioprotección y un uso inadecuado de ellos, urge realizar intervenciones educativas y técnicas para mejorar estos datos.


BACKGROUND: Due to the increasing number of interventional cardiology procedures currently performed, health professionals (POE) are exposed to ionizing radiation unless adequate protective elements are used. AIM: to describe the use of radioprotection elements and dosimetry in interventional cardiology laboratories in South America. METHODS: A self-administered survey was performed on 139 POE of both sexes and 7 countries using an online platform. Demographic data, dosimetry and characteristics of radioprotection analyzed. RESULTS: Commonly used radioprotective elements (lead aprons and collars) were used in 99.5% and 98% respectively. Recently introduced protection elements like lead goggles, caps and drapery were used in 36.8, 6.8 and 34.2% , respectively. Dosimetry according to the International Atomic Energy Commission (OIAE) was performed in only 7.9% of the procedures. CONCLUSION: there is a severe lack of adequate radioprotection during interventional cardiology procedures. Urgent measures, including technical implementation and educational interventions are needed to improve radioprotection in interventional cardiology.


Assuntos
Humanos , Masculino , Feminino , Adulto , Proteção Radiológica/métodos , Radiografia Intervencionista/efeitos adversos , Exposição Ocupacional/prevenção & controle , Serviço Hospitalar de Cardiologia , Doses de Radiação , Radiação Ionizante , Proteção Radiológica/instrumentação , Proteção Radiológica/estatística & dados numéricos , América do Sul , Projetos Piloto , Inquéritos e Questionários , Autorrelato , Equipamento de Proteção Individual
5.
Dentomaxillofac Radiol ; 48(7): 20190014, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31237774

RESUMO

The objective of this paper is to provide recommendations towards the appropriate use of thyroid shielding in dental cone beam CT (CBCT). Based on current evidence of thyroid radiosensitivity, dosimetric data in the presence and absence of shielding, and a depiction of potential adverse effects of thyroid shielding, a concise set of recommendations was prepared. According to current risk models, thyroid sensitivity is particularly high at a young age, and much higher for females. In the literature, involving adult male, female and paediatric reference phantoms, the use of a tightly fitted thyroid collar with a lead-equivalent thickness of at least 0.25 mm has consistently shown a significant reduction (average: 45.9%) of the equivalent dose to the thyroid. It can therefore be recommended that thyroid shielding should be routinely used for children undergoing CBCT scanning and is recommended for adults up to the age of 50. The increase of the X-ray tube current from automatic exposure control systems due to thyroid shielding can be avoided by placing the shielding collar after acquiring the scout images. Should real-time tube current modulation be implemented in dental CBCT imaging in the future, perspectives regarding the appropriate use of shielding may change according to current trends in CT. In view of the manifestation of metal artefacts, shielding is best avoided if radiological evaluation of tissues below the lower border of the mandible is needed.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Proteção Radiológica , Radiografia Dentária/métodos , Glândula Tireoide , Adolescente , Adulto , Criança , Pré-Escolar , Tomografia Computadorizada de Feixe Cônico/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Doses de Radiação , Proteção Radiológica/métodos , Dosimetria Termoluminescente , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...