Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Biofouling ; 39(1): 47-63, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36856008

RESUMO

This study aimed to characterize the immobilization of the novel JIChis-2 peptide on the Ti-6Al-4V alloy, widely used in the biomedical sector. The antimicrobial activity of JIChis-2 was evaluated in the Gram-negative bacterium E. coli. Its immobilization occurred by inducing the formation of covalent bonds between the N-terminus of the peptides and the surface previously submitted to acrylic acid polymerization via the PECVD technique. Coated and uncoated surfaces were characterized by FTIR, AFM, SEM and EDX. Studies of global and localized corrosion were carried out, seeking to explore the effects triggered by surface treatment in an aggressive environment. Additionally, the ability of the functionalized material to prevent E. coli biofilm formation evidenced that the strategy to immobilize JIChis-2 in the Ti-6Al-4V alloy via PECVD of acrylic acid resulted in the development of a functional material with antibiofilm properties.


Assuntos
Peptídeos Antimicrobianos , Escherichia coli , Teste de Materiais , Polimerização , Biofilmes , Titânio/farmacologia , Titânio/química , Ligas/farmacologia , Ligas/química
2.
Bioelectrochemistry ; 136: 107622, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32784103

RESUMO

Ti-6Al-4V alloy has been widely investigated for biomedical applications due to its low density, high specific strength, and favorable corrosion resistance. However, some reported failures have imposed a challenge to improve bone regeneration and fixation, as well as antibacterial properties. A further opportunity for solving this problem is the introduction of porosity. However, this can induce metallic release and corrosion product formation. In this work, a Ti-6Al-4V alloy was exposed to Hank's solution, sterilized and inoculated with Staphylococcus aureus at 37 °C. Surface analysis was carried out by SEM-EDS and XPS. Electrochemical measurements were also performed using chronopotentiometry at open circuit potential, polarization curves, and electrochemical impedance spectroscopy. After exposure, FE-SEM showed some colonies of S. aureus on the sample with 22% porosity. However, XPS analysis revealed that the presence of bacterium influenced the composition of the oxide layer, even more drastically with the increase in added porosity. Moreover, the impedance analysis showed De Levie's behavior, revealing a reduction of pore resistance and modulus of the impedance in the low frequency range in inoculated medium, and polarization curves showed that the passivity potential range was decreased, whereas the passivity current increased in the presence of the S. aureus.


Assuntos
Ligas/química , Técnicas Eletroquímicas/métodos , Staphylococcus aureus/fisiologia , Titânio/química , Espectroscopia Dielétrica , Microscopia Eletrônica de Varredura , Espectroscopia Fotoeletrônica , Porosidade , Staphylococcus aureus/ultraestrutura
3.
Mater Sci Eng C Mater Biol Appl ; 116: 111149, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32806280

RESUMO

Organic-inorganic hybrid coatings deposited on different types of metallic alloys have shown outstanding anticorrosive performance. The incorporation of osteoconductive additives such as hydroxyapatite (HA) and ß-tricalcium phosphate (ß-TCP) into organic-inorganic hybrid coatings is promising to improve the osseointegration and corrosion resistance of Ti6Al4V alloys, which are the most widely used metallic orthopedic and dental implant materials today. Therefore, this study evaluated the capability of poly(methyl methacrylate) (PMMA)-TiO2 and PMMA-ZrO2 hybrid coatings modified with HA and ß-TCP to act as bioactive and corrosion protection coatings for Ti6Al4V alloys. In terms of cell growth and mineralization, osteoblast viability, Ca+2 deposition and alkaline phosphatase assays revealed a significant improvement for the HA and ß-TCP modified coatings, compared to the bare alloy. This can be explained by an increase in nanoscale roughness and associated higher surface free energy, which lead to enhanced protein adsorption to promote osteoblast attachment and functions on the coatings. The effect of HA and ß-TCP additives on the anticorrosive efficiency was studied by electrochemical impedance spectroscopy (EIS) in a simulated body fluid (SBF) solution. The coatings presented a low-frequency impedance modulus of up to 430 GΩ cm2, 5 decades higher than the bare Ti6Al4V alloy. These findings provide clear evidence of the beneficial role of HA and ß-TCP modified hybrid coatings, improving both the biocompatibility and corrosion resistance of the Ti6Al4V alloy.


Assuntos
Materiais Revestidos Biocompatíveis , Durapatita , Polimetil Metacrilato , Ligas/farmacologia , Fosfatos de Cálcio , Materiais Revestidos Biocompatíveis/farmacologia , Corrosão , Teste de Materiais , Propriedades de Superfície , Titânio
4.
Materials (Basel) ; 12(3)2019 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-30744088

RESUMO

The Ti-6Al-4V alloy is widely used in the manufacture of components that must have low density and high corrosion resistance and fatigue strength. The fatigue strength can be improved by surface modification. The aim of this study was to determine the influence of plasma nitriding on the fatigue behavior of a Ti-6Al-4V alloy with a lamellar microstructure (Widmanstätten type). Nitriding was executed at 720 °C for 4 h in an atmosphere with N2, Ar, and H2. Microstructure characterization of the samples was carried out by X-ray diffraction analysis, optical microscopy, and scanning electron microscopy. The average roughness of the specimens was determined, and fatigue tests were executed in a bending⁻rotating machine with reverse tension cycles (R = -1). X-ray diffraction analysis of the nitrided alloy revealed the following matrix phases: α, ß, ε-Ti2N, and δ-TiN. A nitrogen diffusion layer was formed between the substrate and the titanium nitrides. Plasma nitriding resulted in an increase in low-cycle fatigue strength, whereas at high cycles of 200 MPa, both conditions exhibited similar behaviors. The fracture surface of the fatigue-tested specimens clearly revealed the lamellar microstructure. The fracture mechanism in the non-nitrided specimens appears to be due to cracking at the interface of the α and ß phases of the lamellar microstructure.

5.
Mater Sci Eng C Mater Biol Appl ; 33(7): 4197-202, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23910333

RESUMO

Titanium mini-implants have been successfully used as anchorage devices in Orthodontics. Commercially pure titanium (cpTi) was recently replaced by Ti-6Al-4V alloy as the mini-implant material base due to the higher strength properties of the alloy. However, the lower corrosion resistance and the lower biocompatibility have been lowering the success rate of Ti-6Al-4V mini-implants. Nanostructured titanium (nTi) is commercially pure titanium that was nanostructured by a specific technique of severe plastic deformation. It is bioinert, does not contain potentially toxic or allergic additives, and has higher specific strength properties than any other titanium applied in medical implants. The higher strength properties associated to the higher biocompatibility make nTi potentially useful for orthodontic mini-implant applications, theoretically overcoming cpTi and Ti-6Al-4V mini-implants. The purposes of the this work were to process nTi, to mechanically compare cpTi, Ti-6Al-4V, and nTi mini-implants by torque test, and to evaluate both the surface morphology and the fracture surface characteristics of them by SEM. Torque test results showed significant increase in the maximum torque resistance of nTi mini-implants when compared to cpTi mini-implants, and no statistical difference between Ti-6Al-4V and nTi mini-implants. SEM analysis demonstrated smooth surface morphology and transgranular fracture aspect for nTi mini-implants. Since nanostructured titanium mini-implants have mechanical properties comparable to titanium alloy mini-implants, and biocompatibility comparable to commercially pure titanium mini-implants, it is suggestive that nanostructured titanium can replace Ti-6Al-4V alloy as the material base for mini-implants.


Assuntos
Nanoestruturas/química , Ortodontia , Plásticos/química , Titânio/farmacologia , Análise de Variância , Teste de Materiais , Nanoestruturas/ultraestrutura , Próteses e Implantes , Estresse Mecânico , Torque
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA