Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.456
Filtrar
1.
Insights Imaging ; 15(1): 170, 2024 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-38971903

RESUMO

OBJECTIVES: This study aims to investigate how radiomics analysis can help understand the association between plaque texture, epicardial adipose tissue (EAT), and cardiovascular risk. Working with a Photon-counting CT, which exhibits enhanced feature stability, offers the potential to advance radiomics analysis and enable its integration into clinical routines. METHODS: Coronary plaques were manually segmented in this retrospective, single-centre study and radiomic features were extracted using pyradiomics. The study population was divided into groups according to the presence of high-risk plaques (HRP), plaques with at least 50% stenosis, plaques with at least 70% stenosis, or triple-vessel disease. A combined group with patients exhibiting at least one of these risk factors was formed. Random forest feature selection identified differentiating features for the groups. EAT thickness and density were measured and compared with feature selection results. RESULTS: A total number of 306 plaques from 61 patients (mean age 61 years +/- 8.85 [standard deviation], 13 female) were analysed. Plaques of patients with HRP features or relevant stenosis demonstrated a higher presence of texture heterogeneity through various radiomics features compared to patients with only an intermediate stenosis degree. While EAT thickness did not significantly differ, affected patients showed significantly higher mean densities in the 50%, HRP, and combined groups, and insignificantly higher densities in the 70% and triple-vessel groups. CONCLUSION: The combination of a higher EAT density and a more heterogeneous plaque texture might offer an additional tool in identifying patients with an elevated risk of cardiovascular events. CLINICAL RELEVANCE STATEMENT: Cardiovascular disease is the leading cause of mortality globally. Plaque composition and changes in the EAT are connected to cardiac risk. A better understanding of the interrelation of these risk indicators can lead to improved cardiac risk prediction. KEY POINTS: Cardiac plaque composition and changes in the EAT are connected to cardiac risk. Higher EAT density and more heterogeneous plaque texture are related to traditional risk indicators. Radiomics texture analysis conducted on PCCT scans can help identify patients with elevated cardiac risk.

2.
Acad Radiol ; 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38845293

RESUMO

RATIONALE AND OBJECTIVES: Lymphovascular invasion (LVI) plays a significant role in precise treatments of non-small cell lung cancer (NSCLC). This study aims to build a non-invasive LVI prediction diagnosis model by combining preoperative CT images with deep learning technology. MATERIALS AND METHODS: This retrospective observational study included a series of consecutive patients who underwent surgical resection for non-small cell lung cancer (NSCLC) and received pathologically confirmed diagnoses. The cohort was randomly divided into a training group comprising 70 % of the patients and a validation group comprising the remaining 30 %. Four distinct deep convolutional neural network (DCNN) prediction models were developed, incorporating different combination of two-dimensional (2D) and three-dimensional (3D) CT imaging features as well as clinical-radiological data. The predictive capabilities of the models were evaluated by receiver operating characteristic curves (AUC) values and confusion matrices. The Delong test was utilized to compare the predictive performance among the different models. RESULTS: A total of 3034 patients with NSCLC were recruited in this study including 106 LVI+ patients. In the validation cohort, the Dual-head Res2Net_3D23F model achieved the highest AUC of 0.869, closely followed by the models of Dual-head Res2Net_3D3F (AUC, 0.868), Dual-head Res2Net_3D (AUC, 0.867), and EfficientNet-B0_2D (AUC, 0.857). There was no significant difference observed in the performance of the EfficientNet-B0_2D model when compared to the Dual-head Res2Net_3D3F and Dual-head Res2Net_3D23F. CONCLUSION: Findings of this study suggest that utilizing deep convolutional neural network is a feasible approach for predicting pathological LVI in patients with NSCLC.

3.
J Korean Soc Radiol ; 85(3): 649-653, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38873368

RESUMO

A pulmonary artery periadventitial hematoma is a rare complication of a Stanford type A intramural hematoma. As the proximal ascending aorta and pulmonary artery share a common adventitial layer, extravasated blood from the intramural hematoma in the ascending thoracic aorta may extend to beneath the adventitia of the pulmonary artery. The authors describe a case involving a 66-year-old male with acute chest pain who presented with a pulmonary artery periadventitial hematoma associated with a Stanford type A intramural hematoma.

4.
Eur Radiol Exp ; 8(1): 71, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38880866

RESUMO

BACKGROUND: Radiomics is a quantitative approach that allows the extraction of mineable data from medical images. Despite the growing clinical interest, radiomics studies are affected by variability stemming from analysis choices. We aimed to investigate the agreement between two open-source radiomics software for both contrast-enhanced computed tomography (CT) and contrast-enhanced magnetic resonance imaging (MRI) of lung cancers and to preliminarily evaluate the existence of radiomic features stable for both techniques. METHODS: Contrast-enhanced CT and MRI images of 35 patients affected with non-small cell lung cancer (NSCLC) were manually segmented and preprocessed using three different methods. Sixty-six Image Biomarker Standardisation Initiative-compliant features common to the considered platforms, PyRadiomics and LIFEx, were extracted. The correlation among features with the same mathematical definition was analyzed by comparing PyRadiomics and LIFEx (at fixed imaging technique), and MRI with CT results (for the same software). RESULTS: When assessing the agreement between LIFEx and PyRadiomics across the considered resampling, the maximum statistically significant correlations were observed to be 94% for CT features and 95% for MRI ones. When examining the correlation between features extracted from contrast-enhanced CT and MRI using the same software, higher significant correspondences were identified in 11% of features for both software. CONCLUSIONS: Considering NSCLC, (i) for both imaging techniques, LIFEx and PyRadiomics agreed on average for 90% of features, with MRI being more affected by resampling and (ii) CT and MRI contained mostly non-redundant information, but there are shape features and, more importantly, texture features that can be singled out by both techniques. RELEVANCE STATEMENT: Identifying and selecting features that are stable cross-modalities may be one of the strategies to pave the way for radiomics clinical translation. KEY POINTS: • More than 90% of LIFEx and PyRadiomics features contain the same information. • Ten percent of features (shape, texture) are stable among contrast-enhanced CT and MRI. • Software compliance and cross-modalities stability features are impacted by the resampling method.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Imageamento por Ressonância Magnética , Software , Tomografia Computadorizada por Raios X , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Meios de Contraste , Radiômica
5.
Insights Imaging ; 15(1): 144, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38886276

RESUMO

OBJECTIVES: To quantify the relationship between abdominal computed tomography (CT)-based body composition parameters and renal function in systemic lupus erythematosus (SLE) patients and evaluate the potential effect of insulin resistance on this relationship. METHODS: SLE patients from institutions A and B between January 2017 and August 2023 were enrolled. Areas and attenuation values of subcutaneous adipose tissue, visceral adipose tissue, intermuscular adipose tissue (IMAT), and skeletal muscle index on CT images were measured at the L3 vertebral level. Logistic regression analysis was used to identify risk factors associated with decreased renal function. Linear regression models were used to describe the relationships between body composition parameters and estimated glomerular filtration rate (eGFR). Finally, we used a single-point insulin sensitivity estimator to indirectly reflect the degree of insulin resistance and assess its mediating effect on the association between IMAT area and decreased renal function. RESULTS: Three-hundred thirty-nine SLE patients from institution A (internal dataset) and 114 SLE patients from institution B (external validation dataset) were included. Multivariate logistic regression revealed that IMAT area (odds ratio (OR)institution A: 1.05 (95% confidence intervals (95% CI): 1.01, 1.10), and ORinstitution B: 1.19 (95% CI: 1.03, 1.39)) was an independent risk factor for decreased renal function in SLE patients. In the adjusted linear regression model, high IMAT area was significantly associated with reduced eGFR (ßinstitution A = -1.15, Pinstitution A = 0.005; ßinstitution B = -0.98, Pinstitution B = 0.049). Additionally, insulin resistance contributed a mediating role of 22.8% to the association. CONCLUSION: High IMAT area was associated with decreased renal function in SLE patients and insulin resistance mediated this relationship. CRITICAL RELEVANCE STATEMENT: High intermuscular adipose tissue area is associated with decreased renal function in systemic lupus erythematosus patients mediated by insulin resistance and is correlated with chronicity index in lupus nephritis patients. KEY POINTS: High intramuscular adipose tissue (IMAT) area was associated with decreased renal function in systemic lupus erythematosus (SLE) patients. Insulin resistance mediated the association between IMAT area and eGFR. IMAT area was associated with chronicity index in lupus nephritis patients.

6.
Eur Radiol Exp ; 8(1): 70, 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38890175

RESUMO

BACKGROUND: The potential role of cardiac computed tomography (CT) has increasingly been demonstrated for the assessment of diffuse myocardial fibrosis through the quantification of extracellular volume (ECV). Photon-counting detector (PCD)-CT technology may deliver more accurate ECV quantification compared to energy-integrating detector CT. We evaluated the impact of reconstruction settings on the accuracy of ECV quantification using PCD-CT, with magnetic resonance imaging (MRI)-based ECV as reference. METHODS: In this post hoc analysis, 27 patients (aged 53.1 ± 17.2 years (mean ± standard deviation); 14 women) underwent same-day cardiac PCD-CT and MRI. Late iodine CT scans were reconstructed with different quantum iterative reconstruction levels (QIR 1-4), slice thicknesses (0.4-8 mm), and virtual monoenergetic imaging levels (VMI, 40-90 keV); ECV was quantified for each reconstruction setting. Repeated measures ANOVA and t-test for pairwise comparisons, Bland-Altman plots, and Lin's concordance correlation coefficient (CCC) were used. RESULTS: ECV values did not differ significantly among QIR levels (p = 1.000). A significant difference was observed throughout different slice thicknesses, with 0.4 mm yielding the highest agreement with MRI-based ECV (CCC = 0.944); 45-keV VMI reconstructions showed the lowest mean bias (0.6, 95% confidence interval 0.1-1.4) compared to MRI. Using the most optimal reconstruction settings (QIR4. slice thickness 0.4 mm, VMI 45 keV), a 63% reduction in mean bias and a 6% increase in concordance with MRI-based ECV were achieved compared to standard settings (QIR3, slice thickness 1.5 mm; VMI 65 keV). CONCLUSIONS: The selection of appropriate reconstruction parameters improved the agreement between PCD-CT and MRI-based ECV. RELEVANCE STATEMENT: Tailoring PCD-CT reconstruction parameters optimizes ECV quantification compared to MRI, potentially improving its clinical utility. KEY POINTS: • CT is increasingly promising for myocardial tissue characterization, assessing focal and diffuse fibrosis via late iodine enhancement and ECV quantification, respectively. • PCD-CT offers superior performance over conventional CT, potentially improving ECV quantification and its agreement with MRI-based ECV. • Tailoring PCD-CT reconstruction parameters optimizes ECV quantification compared to MRI, potentially improving its clinical utility.


Assuntos
Imageamento por Ressonância Magnética , Miocárdio , Tomografia Computadorizada por Raios X , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia , Idoso , Fótons , Adulto , Processamento de Imagem Assistida por Computador/métodos , Coração/diagnóstico por imagem
7.
Eur Radiol Exp ; 8(1): 69, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38862843

RESUMO

BACKGROUND: Dual-energy computed tomography (DECT) is useful for detecting gouty tophi. While iodinated contrast media (ICM) might enhance the detection of monosodium urate crystals (MSU), higher iodine concentrations hamper their detection. Calculating virtual noncontrast (VNC) images might improve the detection of enhancing tophi. The aim of this study was to evaluate MSU detection with VNC images from DECT acquisitions in phantoms, compared against the results with standard DECT reconstructions. METHODS: A grid-like and a biophantom with 25 suspensions containing different concentrations of ICM (0 to 2%) and MSU (0 to 50%) were scanned with sequential single-source DECT using an ascending order of tube current time product at 80 kVp (16.5-220 mAs) and 135 kVp (2.75-19.25 mAs). VNC images were equivalently reconstructed at 80 and 135 kVp. Two-material decomposition analysis for MSU detection was applied for the VNC and conventional CT images. MSU detection and attenuation values were compared in both modalities. RESULTS: For 0, 0.25, 0.5, 1, and 2% ICM, the average detection indices (DIs) for all MSU concentrations (35-50%) with VNC postprocessing were respectively 25.2, 36.6, 30.9, 38.9, and 45.8% for the grid phantom scans and 11.7, 9.4, 5.5, 24.0, and 25.0% for the porcine phantom scans. In the conventional CT image group, the average DIs were respectively 35.4, 54.3, 45.4, 1.0, and 0.0% for the grid phantom and 19.4, 17.9, 3.0, 0.0, and 0.0% for the porcine phantom scans. CONCLUSIONS: VNC effectively reduces the suppression of information caused by high concentrations of ICM, thereby improving the detection of MSU. RELEVANCE STATEMENT: Contrast-enhanced DECT alone may suffice for diagnosing gout without a native acquisition. KEY POINTS: • Highly concentrated contrast media hinders monosodium urate crystal detection in CT imaging • Virtual noncontrast imaging redetects monosodium urate crystals in high-iodinated contrast media concentrations. • Contrast-enhanced DECT alone may suffice for diagnosing gout without a native acquisition.


Assuntos
Meios de Contraste , Gota , Imagens de Fantasmas , Tomografia Computadorizada por Raios X , Ácido Úrico , Tomografia Computadorizada por Raios X/métodos , Ácido Úrico/análise , Gota/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Animais , Suínos
8.
Stroke ; 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38934573
9.
Artigo em Inglês | MEDLINE | ID: mdl-38941179

RESUMO

INTRODUCTION: Our objective was to investigate the utility of fluorodeoxyglucose positron emission tomography-computed tomography (FDG PET-CT) in assessing CT Stage 1A non-small cell lung cancer (NSCLC) in patients under consideration for curative treatment. Performing FDG PET-CT in these patients may lead to unnecessary delays in treatment if it can be shown to provide no added value. METHODS: We retrospectively reviewed 735 lesions in 653 patients from the New Zealand Te Whatu Ora Northern region lung cancer database with suspected or pathologically proven Stage 1A NSCLC on CT scan who also underwent FDG PET-CT imaging. We determined how often FDG PET-CT findings upstaged patients and then compared to pathological staging where available. RESULTS: FDG PET-CT provided an overall upstaging rate of 9.7%. Category-specific rates were 0% in Tis, 0.9% in T1mi, 7.4% in T1a, 10% in T1b and 12% in T1c groups. The percentage of lesions upstaged on FDG PET-CT that remained Stage 1A was 100% in T1mi, 100% in T1a, 47.1% in T1b and 40.7% in T1c groups. The P value was statistically significant at 0.004, indicating upstaging beyond Stage 1A was dependent on T category. CONCLUSION: Our data suggests that FDG PET-CT is indicated for T1b and T1c lesions but is of limited utility in Tis, T1mi and T1a lesions. Adopting a more targeted approach and omitting FDG PET-CT in patients with Tis, T1mi, and T1a lesions may benefit all patients with lung cancer by improving accessibility and treatment timelines.

10.
Eur J Radiol ; 176: 111503, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38761443

RESUMO

PURPOSE: We determine and compare the prevalence, subtypes, severity, and risk factors for emphysema assessed by low-dose CT(LDCT) in Chinese and Dutch general populations. METHODS: This cross-sectional study included LDCT scans of 1143 participants between May and October 2017 from a Chinese Cohort study and 1200 participants with same age range and different smoking status between May and October 2019 from a Dutch population-based study. An experienced radiologist visually assessed the scans for emphysema presence (≥trace), subtype, and severity. Logistic regression analyses, overall and stratified by smoking status, were performed and adjusted for fume exposure, demographic and smoking data. RESULTS: The Chinese population had a comparable proportion of women to the Dutch population (54.9 % vs 58.9 %), was older (61.7 ± 6.3 vs 59.8 ± 8.1), included more never smokers (66.4 % vs 38.3 %), had a higher emphysema prevalence ([58.8 % vs 39.7 %], adjusted odds ratio, aOR = 2.06, 95 %CI = 1.68-2.53), and more often had centrilobular emphysema (54.8 % vs 32.8 %, p < 0.001), but no differences in emphysema severity. After stratification, only in never smokers an increased odds of emphysema was observed in the Chinese compared to the Dutch (aOR = 2.55, 95 %CI = 1.95-3.35). Never smokers in both populations shared older age (aOR = 1.59, 95 %CI = 1.25-2.02 vs 1.26, 95 %CI = 0.97-1.64) and male sex (aOR = 1.50, 95 %CI = 1.02-2.22 vs 1.93, 95 %CI = 1.26-2.96) as risk factors for emphysema. CONCLUSIONS: Only never smokers had a higher prevalence of mainly centrilobular emphysema in the Chinese general population compared to the Dutch after adjusting for confounders, indicating that factors other than smoking, age and sex contribute to presence of CT-defined emphysema.


Assuntos
Enfisema Pulmonar , Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Prevalência , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Enfisema Pulmonar/diagnóstico por imagem , Enfisema Pulmonar/epidemiologia , Estudos Transversais , China/epidemiologia , Fatores de Risco , Idoso , Fumar/epidemiologia , Índice de Gravidade de Doença , População do Leste Asiático
11.
Eur Radiol Exp ; 8(1): 55, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38705940

RESUMO

BACKGROUND: To evaluate the reproducibility of a vessel-specific minimum cost path (MCP) technique used for lobar segmentation on noncontrast computed tomography (CT). METHODS: Sixteen Yorkshire swine (49.9 ± 4.7 kg, mean ± standard deviation) underwent a total of 46 noncontrast helical CT scans from November 2020 to May 2022 using a 320-slice scanner. A semiautomatic algorithm was employed by three readers to segment the lung tissue and pulmonary arterial tree. The centerline of the arterial tree was extracted and partitioned into six subtrees for lobar assignment. The MCP technique was implemented to assign lobar territories by assigning lung tissue voxels to the nearest arterial tree segment. MCP-derived lobar mass and volume were then compared between two acquisitions, using linear regression, root mean square error (RMSE), and paired sample t-tests. An interobserver and intraobserver analysis of the lobar measurements was also performed. RESULTS: The average whole lung mass and volume was 663.7 ± 103.7 g and 1,444.22 ± 309.1 mL, respectively. The lobar mass measurements from the initial (MLobe1) and subsequent (MLobe2) acquisitions were correlated by MLobe1 = 0.99 MLobe2 + 1.76 (r = 0.99, p = 0.120, RMSE = 7.99 g). The lobar volume measurements from the initial (VLobe1) and subsequent (VLobe2) acquisitions were correlated by VLobe1 = 0.98VLobe2 + 2.66 (r = 0.99, p = 0.160, RSME = 15.26 mL). CONCLUSIONS: The lobar mass and volume measurements showed excellent reproducibility through a vessel-specific assignment technique. This technique may serve for automated lung lobar segmentation, facilitating clinical regional pulmonary analysis. RELEVANCE STATEMENT: Assessment of lobar mass or volume in the lung lobes using noncontrast CT may allow for efficient region-specific treatment strategies for diseases such as pulmonary embolism and chronic thromboembolic pulmonary hypertension. KEY POINTS: • Lobar segmentation is essential for precise disease assessment and treatment planning. • Current methods for segmentation using fissure lines are problematic. • The minimum-cost-path technique here is proposed and a swine model showed excellent reproducibility for lobar mass measurements. • Interobserver agreement was excellent, with intraclass correlation coefficients greater than 0.90.


Assuntos
Pulmão , Animais , Suínos , Pulmão/diagnóstico por imagem , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Modelos Animais , Algoritmos
12.
Eur Radiol ; 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38806803

RESUMO

OBJECTIVES: Arterial calcification is thought to protect against rupture of intracranial aneurysms, but studies in a representative population of intracranial aneurysm patients have not yet been performed. The aim was to compare the prevalence of aneurysm wall calcification and intracranial carotid artery calcification (ICAC) between patients with an unruptured intracranial aneurysm (UIA) and a ruptured intracranial aneurysm (RIA). MATERIALS AND METHODS: We matched 150 consecutive UIA patients to 150 RIA patients on age and sex. Aneurysm wall calcification and ICAC were quantified on non-contrast enhanced computed tomography images with the modified Agatston score. We compared the prevalence of aneurysm wall calcification, ICAC, and severe ICAC (defined as a modified Agatston score in the fourth quartile) between UIA and RIA patients using univariate and multivariate conditional logistic regression models adjusted for aneurysm characteristics and cardiovascular risk factors. RESULTS: Aneurysm wall calcification was more prevalent in UIA compared to RIA patients (OR 5.2, 95% CI: 2.0-13.8), which persisted after adjustment (OR 5.9, 95% CI: 1.7-20.2). ICAC prevalence did not differ between the two groups (crude OR 0.9, 95% CI: 0.5-1.8). Severe ICAC was more prevalent in UIA patients (OR 2.0, 95% CI: 1.1-3.6), but not after adjustment (OR 1.0, 95% CI: 0.5-2.3). CONCLUSIONS: Aneurysm wall calcification but not ICAC was more prevalent in UIAs than in RIAs, which corresponds to the hypothesis that calcification may protect against aneurysmal rupture. Aneurysm wall calcification should be further assessed as a predictor of aneurysm stability in prospective cohort studies. CLINICAL RELEVANCE STATEMENT: Calcification of the intracranial aneurysm wall was more prevalent in unruptured than ruptured intracranial aneurysms after adjustment for cardiovascular risk factors. Calcification may therefore protect the aneurysm against rupture, and aneurysm wall calcification is a candidate predictor of aneurysm stability. KEY POINTS: Aneurysm wall calcification was more prevalent in patients with unruptured than ruptured aneurysms, while internal carotid artery calcification was similar. Aneurysm wall calcification but not internal carotid artery calcification is a candidate predictor of aneurysm stability. Cohort studies are needed to assess the predictive value of aneurysm wall calcification for aneurysm stability.

13.
Eur Radiol Exp ; 8(1): 57, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38724831

RESUMO

BACKGROUND: We compared computed tomography (CT) images and holograms (HG) to assess the number of arteries of the lung lobes undergoing lobectomy and assessed easiness in interpretation by radiologists and thoracic surgeons with both techniques. METHODS: Patients scheduled for lobectomy for lung cancer were prospectively included and underwent CT for staging. A patient-specific three-dimensional model was generated and visualized in an augmented reality setting. One radiologist and one thoracic surgeon evaluated CT images and holograms to count lobar arteries, having as reference standard the number of arteries recorded at surgery. The easiness of vessel identification was graded according to a Likert scale. Wilcoxon signed-rank test and κ statistics were used. RESULTS: Fifty-two patients were prospectively included. The two doctors detected the same number of arteries in 44/52 images (85%) and in 51/52 holograms (98%). The mean difference between the number of artery branches detected by surgery and CT images was 0.31 ± 0.98, whereas it was 0.09 ± 0.37 between surgery and HGs (p = 0.433). In particular, the mean difference in the number of arteries detected in the upper lobes was 0.67 ± 1.08 between surgery and CT images and 0.17 ± 0.46 between surgery and holograms (p = 0.029). Both radiologist and surgeon showed a higher agreement for holograms (κ = 0.99) than for CT (κ = 0.81) and found holograms easier to evaluate than CTs (p < 0.001). CONCLUSIONS: Augmented reality by holograms is an effective tool for preoperative vascular anatomy assessment of lungs, especially when evaluating the upper lobes, more prone to anatomical variations. TRIAL REGISTRATION: ClinicalTrials.gov, NCT04227444 RELEVANCE STATEMENT: Preoperative evaluation of the lung lobe arteries through augmented reality may help the thoracic surgeons to carefully plan a lobectomy, thus contributing to optimize patients' outcomes. KEY POINTS: • Preoperative assessment of the lung arteries may help surgical planning. • Lung artery detection by augmented reality was more accurate than that by CT images, particularly for the upper lobes. • The assessment of the lung arterial vessels was easier by using holograms than CT images.


Assuntos
Realidade Aumentada , Holografia , Neoplasias Pulmonares , Artéria Pulmonar , Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Tomografia Computadorizada por Raios X/métodos , Idoso , Estudos Prospectivos , Neoplasias Pulmonares/cirurgia , Neoplasias Pulmonares/diagnóstico por imagem , Pessoa de Meia-Idade , Holografia/métodos , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/anatomia & histologia , Imageamento Tridimensional , Padrões de Referência , Pulmão/diagnóstico por imagem , Pulmão/irrigação sanguínea , Pulmão/cirurgia
14.
Eur Radiol Exp ; 8(1): 54, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38698099

RESUMO

BACKGROUND: We aimed to improve the image quality (IQ) of sparse-view computed tomography (CT) images using a U-Net for lung metastasis detection and determine the best tradeoff between number of views, IQ, and diagnostic confidence. METHODS: CT images from 41 subjects aged 62.8 ± 10.6 years (mean ± standard deviation, 23 men), 34 with lung metastasis, 7 healthy, were retrospectively selected (2016-2018) and forward projected onto 2,048-view sinograms. Six corresponding sparse-view CT data subsets at varying levels of undersampling were reconstructed from sinograms using filtered backprojection with 16, 32, 64, 128, 256, and 512 views. A dual-frame U-Net was trained and evaluated for each subsampling level on 8,658 images from 22 diseased subjects. A representative image per scan was selected from 19 subjects (12 diseased, 7 healthy) for a single-blinded multireader study. These slices, for all levels of subsampling, with and without U-Net postprocessing, were presented to three readers. IQ and diagnostic confidence were ranked using predefined scales. Subjective nodule segmentation was evaluated using sensitivity and Dice similarity coefficient (DSC); clustered Wilcoxon signed-rank test was used. RESULTS: The 64-projection sparse-view images resulted in 0.89 sensitivity and 0.81 DSC, while their counterparts, postprocessed with the U-Net, had improved metrics (0.94 sensitivity and 0.85 DSC) (p = 0.400). Fewer views led to insufficient IQ for diagnosis. For increased views, no substantial discrepancies were noted between sparse-view and postprocessed images. CONCLUSIONS: Projection views can be reduced from 2,048 to 64 while maintaining IQ and the confidence of the radiologists on a satisfactory level. RELEVANCE STATEMENT: Our reader study demonstrates the benefit of U-Net postprocessing for regular CT screenings of patients with lung metastasis to increase the IQ and diagnostic confidence while reducing the dose. KEY POINTS: • Sparse-projection-view streak artifacts reduce the quality and usability of sparse-view CT images. • U-Net-based postprocessing removes sparse-view artifacts while maintaining diagnostically accurate IQ. • Postprocessed sparse-view CTs drastically increase radiologists' confidence in diagnosing lung metastasis.


Assuntos
Neoplasias Pulmonares , Tomografia Computadorizada por Raios X , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Feminino , Estudos Retrospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso
15.
Eur Radiol Exp ; 8(1): 63, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38764066

RESUMO

BACKGROUND: Emphysema influences the appearance of lung tissue in computed tomography (CT). We evaluated whether this affects lung nodule detection by artificial intelligence (AI) and human readers (HR). METHODS: Individuals were selected from the "Lifelines" cohort who had undergone low-dose chest CT. Nodules in individuals without emphysema were matched to similar-sized nodules in individuals with at least moderate emphysema. AI results for nodular findings of 30-100 mm3 and 101-300 mm3 were compared to those of HR; two expert radiologists blindly reviewed discrepancies. Sensitivity and false positives (FPs)/scan were compared for emphysema and non-emphysema groups. RESULTS: Thirty-nine participants with and 82 without emphysema were included (n = 121, aged 61 ± 8 years (mean ± standard deviation), 58/121 males (47.9%)). AI and HR detected 196 and 206 nodular findings, respectively, yielding 109 concordant nodules and 184 discrepancies, including 118 true nodules. For AI, sensitivity was 0.68 (95% confidence interval 0.57-0.77) in emphysema versus 0.71 (0.62-0.78) in non-emphysema, with FPs/scan 0.51 and 0.22, respectively (p = 0.028). For HR, sensitivity was 0.76 (0.65-0.84) and 0.80 (0.72-0.86), with FPs/scan of 0.15 and 0.27 (p = 0.230). Overall sensitivity was slightly higher for HR than for AI, but this difference disappeared after the exclusion of benign lymph nodes. FPs/scan were higher for AI in emphysema than in non-emphysema (p = 0.028), while FPs/scan for HR were higher than AI for 30-100 mm3 nodules in non-emphysema (p = 0.009). CONCLUSIONS: AI resulted in more FPs/scan in emphysema compared to non-emphysema, a difference not observed for HR. RELEVANCE STATEMENT: In the creation of a benchmark dataset to validate AI software for lung nodule detection, the inclusion of emphysema cases is important due to the additional number of FPs. KEY POINTS: • The sensitivity of nodule detection by AI was similar in emphysema and non-emphysema. • AI had more FPs/scan in emphysema compared to non-emphysema. • Sensitivity and FPs/scan by the human reader were comparable for emphysema and non-emphysema. • Emphysema and non-emphysema representation in benchmark dataset is important for validating AI.


Assuntos
Inteligência Artificial , Enfisema Pulmonar , Tomografia Computadorizada por Raios X , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Tomografia Computadorizada por Raios X/métodos , Enfisema Pulmonar/diagnóstico por imagem , Software , Sensibilidade e Especificidade , Neoplasias Pulmonares/diagnóstico por imagem , Idoso , Doses de Radiação , Nódulo Pulmonar Solitário/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
16.
BMC Pulm Med ; 24(1): 246, 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38762472

RESUMO

BACKGROUND: The application of radiomics in thoracic lymph node metastasis (LNM) of lung adenocarcinoma is increasing, but diagnostic performance of radiomics from primary tumor to predict LNM has not been systematically reviewed. Therefore, this study sought to provide a general overview regarding the methodological quality and diagnostic performance of using radiomic approaches to predict the likelihood of LNM in lung adenocarcinoma. METHODS: Studies were gathered from literature databases such as PubMed, Embase, the Web of Science Core Collection, and the Cochrane library. The Radiomic Quality Score (RQS) and the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) were both used to assess the quality of each study. The pooled sensitivity, specificity, and area under the curve (AUC) of the best radiomics models in the training and validation cohorts were calculated. Subgroup and meta-regression analyses were also conducted. RESULTS: Seventeen studies with 159 to 1202 patients each were enrolled between the years of 2018 to 2022, of which ten studies had sufficient data for the quantitative evaluation. The percentage of RQS was between 11.1% and 44.4% and most of the studies were considered to have a low risk of bias and few applicability concerns in QUADAS-2. Pyradiomics and logistic regression analysis were the most commonly used software and methods for radiomics feature extraction and selection, respectively. In addition, the best prediction models in seventeen studies were mainly based on radiomics features combined with non-radiomics features (semantic features and/or clinical features). The pooled sensitivity, specificity, and AUC of the training cohorts were 0.84 (95% confidence interval (CI) [0.73-0.91]), 0.88 (95% CI [0.81-0.93]), and 0.93(95% CI [0.90-0.95]), respectively. For the validation cohorts, the pooled sensitivity, specificity, and AUC were 0.89 (95% CI [0.82-0.94]), 0.86 (95% CI [0.74-0.93]) and 0.94 (95% CI [0.91-0.96]), respectively. CONCLUSIONS: Radiomic features based on the primary tumor have the potential to predict preoperative LNM of lung adenocarcinoma. However, radiomics workflow needs to be standardized to better promote the applicability of radiomics. TRIAL REGISTRATION: CRD42022375712.


Assuntos
Adenocarcinoma de Pulmão , Neoplasias Pulmonares , Metástase Linfática , Humanos , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Adenocarcinoma de Pulmão/diagnóstico por imagem , Adenocarcinoma de Pulmão/patologia , Metástase Linfática/diagnóstico por imagem , Valor Preditivo dos Testes , Linfonodos/patologia , Linfonodos/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Sensibilidade e Especificidade , Radiômica
17.
Emerg Radiol ; 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38816544

RESUMO

PURPOSE: In this cross-sectional study, we aimed to characterize how frequently the anatomy of interest (AOI) was excluded when evaluating genital pathology using the current CT pelvis protocol recommended by the American College of Radiology and evaluate how AOI exclusion affects patient management. METHODS: We retrospectively reviewed medical records, using diagnosis and CPT codes, of patients admitted with genital pathology who obtained a CT scan at our institution from July 1, 2020-April 30, 2023. Baseline patient demographics were included. Data about each index CT scan (scan obtained at our institution) were recorded and assessed for exclusion of the AOI. Statistical analysis was performed to determine the rate of AOI exclusion and to compare patient management between patients with AOI excluded versus those without AOI exclusion. RESULTS: 113 presentations for genital pathology included an index CT scan and were included for analysis. Patients were primarily men (98%) with a mean age of 53.1 years (SD 13.9). The most common diagnoses were Fournier's gangrene (35%), scrotal abscess (22%) and unspecified infection (19%). 26/113 scans (23%) did not capture the entire AOI. When the AOI was missed during the index scan, there was a higher rate of obtaining additional scans (38% vs. 21%), but a similar rate of intervention (77% vs. 63%) when compared to index scans that captured the entire AOI. 35 scans (31%) had protocol-extending instructions; index scans that captured the entire AOI were more likely to have specific protocol-extending instructions (38% vs. 8% p < 0.01). CONCLUSIONS: Creating a specific CT protocol for genital pathology could decrease the amount of inappropriate irradiation and improve AOI capture rates without relying on specific request for protocol deviation.

18.
Artigo em Inglês | MEDLINE | ID: mdl-38796803

RESUMO

PURPOSE: This study examines the hepatic extracellular volume fraction (ECV) disparity between the left and right lobes (ECV_left and ECV_right) in patients with chronic thromboembolic pulmonary hypertension (CTEPH), its association with right heart catheterization (RHC) metrics, and with intolerance to increased pulmonary hypertension (PH)-targeted medication dosages. METHODS: We retrospectively analyzed 72 CTEPH-diagnosed patients who underwent equilibrium-phase abdominal dual-energy CT (DECT) and RHC. Hepatic ECVs, derived from DECT's iodine maps using circular regions of interest in the liver and aorta, were correlated with RHC parameters via Spearman's rank correlation and lobe differences through the Wilcoxon signed-rank test. Logistic regression assessed cases with ECV_left exceeding ECV_right by > 0.05, while receiver operating characteristic curve analysis gauged ECVs' predictive power for medication intolerance. RESULTS: Of the 72 patients (57 females; median age 69), ECV_total (0.24, IQR 0.20-0.27) moderately correlated with RHC parameters (rs = 0.28, -0.24, 0.3 for mean pulmonary arterial pressure, cardiac index [CI], and pulmonary vascular resistance index, respectively). ECV_left significantly surpassed ECV_right (0.25 vs. 0.22, p < 0.001), with a greater ECV_left by > 0.05 indicating notably lower CI (p < 0.001). In 27 patients on PH medication, ECV_left effectively predicted medication intolerance (AUC = 0.84). CONCLUSION: In CTEPH patients, hepatic ECV correlated with RHC metrics, where elevated left lobe ECV suggested reduced CI and potential medication intolerance.

19.
Eur Radiol Exp ; 8(1): 50, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38570418

RESUMO

BACKGROUND: Heartbeat-based cross-sectional area (CSA) changes in the right main pulmonary artery (MPA), which reflects its distensibility associated with pulmonary hypertension, can be measured using dynamic ventilation computed tomography (DVCT) in patients with and without chronic obstructive pulmonary disease (COPD) during respiratory dynamics. We investigated the relationship between MPA distensibility (MPAD) and respiratory function and how heartbeat-based CSA is related to spirometry, mean lung density (MLD), and patient characteristics. METHODS: We retrospectively analyzed DVCT performed preoperatively in 37 patients (20 female and 17 males) with lung cancer aged 70.6 ± 7.9 years (mean ± standard deviation), 18 with COPD and 19 without. MPA-CSA was separated into respiratory and heartbeat waves by discrete Fourier transformation. For the cardiac pulse-derived waves, CSA change (CSAC) and CSA change ratio (CSACR) were calculated separately during inhalation and exhalation. Spearman rank correlation was computed. RESULT: In the group without COPD as well as all cases, CSACR exhalation was inversely correlated with percent residual lung volume (%RV) and RV/total lung capacity (r = -0.68, p = 0.003 and r = -0.58, p = 0.014). In contrast, in the group with COPD, CSAC inhalation was correlated with MLDmax and MLD change rate (MLDmax/MLDmin) (r = 0.54, p = 0.020 and r = 0.64, p = 0.004) as well as CSAC exhalation and CSACR exhalation. CONCLUSION: In patients with insufficient exhalation, right MPAD during exhalation was decreased. Also, in COPD patients with insufficient exhalation, right MPAD was reduced during inhalation as well as exhalation, which implied that exhalation impairment is a contributing factor to pulmonary hypertension complicated with COPD. RELEVANCE STATEMENT: Assessment of MPAD in different respiratory phases on DVCT has the potential to be utilized as a non-invasive assessment for pulmonary hypertension due to lung disease and/or hypoxia and elucidation of its pathogenesis. KEY POINTS: • There are no previous studies analyzing all respiratory phases of right main pulmonary artery distensibility (MPAD). • Patients with exhalation impairment decreased their right MPAD. • Analysis of MPAD on dynamic ventilation computed tomography contributes to understanding the pathogenesis of pulmonary hypertension due to lung disease and/or hypoxia in patients with expiratory impairment.


Assuntos
Hipertensão Pulmonar , Pneumopatias , Doença Pulmonar Obstrutiva Crônica , Masculino , Humanos , Feminino , Artéria Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/complicações , Estudos Retrospectivos , Pulmão/diagnóstico por imagem , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Doença Pulmonar Obstrutiva Crônica/complicações , Tomografia Computadorizada por Raios X/métodos , Hipóxia/complicações
20.
Eur Radiol Exp ; 8(1): 52, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38575701

RESUMO

BACKGROUND: Nowadays, there is no method to quantitatively characterize the material composition of acute ischemic stroke thrombi prior to intervention, but dual-energy CT (DE-CT) offers imaging-based multimaterial decomposition. We retrospectively investigated the material composition of thrombi ex vivo using DE-CT with histological analysis as a reference. METHODS: Clots of 70 patients with acute ischemic stroke were extracted by mechanical thrombectomy and scanned ex vivo in formalin-filled tubes with DE-CT. Multimaterial decomposition in the three components, i.e., red blood cells (RBC), white blood cells (WBC), and fibrin/platelets (F/P), was performed and compared to histology (hematoxylin/eosin staining) as reference. Attenuation and effective Z values were assessed, and histological composition was compared to stroke etiology according to the Trial of ORG 10172 in Acute Stroke Treatment (TOAST) criteria. RESULTS: Histological and imaging analysis showed the following correlation coefficients for RBC (r = 0.527, p < 0.001), WBC (r = 0.305, p = 0.020), and F/P (r = 0.525, p < 0.001). RBC-rich thrombi presented higher clot attenuation in Hounsfield units than F/P-rich thrombi (51 HU versus 42 HU, p < 0.01). In histological analysis, cardioembolic clots showed less RBC (40% versus 56%, p = 0.053) and more F/P (53% versus 36%, p = 0.024), similar to cryptogenic clots containing less RBC (34% versus 56%, p = 0.006) and more F/P (58% versus 36%, p = 0.003) than non-cardioembolic strokes. No difference was assessed for the mean WBC portions in all TOAST groups. CONCLUSIONS: DE-CT has the potential to quantitatively characterize the material composition of ischemic stroke thrombi. RELEVANCE STATEMENT: Using DE-CT, the composition of ischemic stroke thrombi can be determined. Knowledge of histological composition prior to intervention offers the opportunity to define personalized treatment strategies for each patient to accomplish faster recanalization and better clinical outcomes. KEY POINTS: • Acute ischemic stroke clots present different recanalization success according to histological composition. • Currently, no method can determine clot composition prior to intervention. • DE-CT allows quantitative material decomposition of thrombi ex vivo in red blood cells, white blood cells, and fibrin/platelets. • Histological clot composition differs between stroke etiology. • Insights into the histological composition in situ offer personalized treatment strategies.


Assuntos
AVC Isquêmico , Acidente Vascular Cerebral , Trombose , Humanos , Fibrina/análise , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/patologia , Acidente Vascular Cerebral/terapia , Trombose/diagnóstico por imagem , Trombose/patologia , Trombose/terapia , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...