Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
1.
Dent Mater J ; 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38825451

RESUMO

Highly polished 3, 4, and 5 mol% yttria-stabilized zirconia and CAD/CAM composite resin samples were prepared, and the influence of surface roughness (Ra and Sa, 21 areas/group), wettability (contact angle and surface energy, 3 samples/group), and surface chemical composition (2 samples/group) on single-strain bacterial adhesion models (Porphyromonas gingivalis, Streptococcus oralis, Streptococcus sanguinis, Streptococcus gordonii, and Streptococcus mutans) were compared via fluorescent staining with graphical analysis (21 areas/group). Statistical analysis was performed using the Shapiro-Wilk test followed by one-way analysis of variance with Tukey's test or the Kruskal-Wallis test with Dunn's test (α=0.05) and linear regression. For dental zirconia with the same surface roughness, the yttria content did not significantly influence the initial bacterial adhesion. However, higher bacterial adhesion was detected for the composite resin owing to its high C, O, and Si contents. There was no correlation between surface energy and bacterial adhesion for any bacterial strain (p<0.005).

2.
BMC Oral Health ; 24(1): 309, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38443872

RESUMO

BACKGROUND: Recent forms of translucent zirconia material have been developed, offering a wide range of options and varieties for enhancing aesthetics, making it a preferred choice in the field of prosthetic dentistry. However, there is insufficient understanding regarding the recent types of zirconia materials and their optical behavior. Understanding the variables that influence the translucency of zirconia and identifying strategies to enhance its esthetics are crucial. PURPOSE: The current systemic review highlights a comprehensive understanding of different zirconia generations in relation to their optical characteristics and evaluates material-related variables affecting their translucency. METHODS: The present review studied in-vitro studies that evaluated the optical characteristics of different yttria content of yttria stabilized materials. The topics explored were: (1) the different zirconia material generations and their optical behavior; (2) material-related factors that affect their translucency. The research was restricted to online publication in the English language from July 1, 2010, to July 31, 2023, using PubMed, Scopus, and Science Direct resources. The search key terms and their combinations were "zirconia," "translucent zirconia," "cubic zirconia," "highly translucent zirconia," "yttria partially stabilized zirconia," "monolithic zirconia," "translucency," "optical properties," and "light transmission." RESULTS: The data obtained from fifty-three studies addressed the optical characteristics of various zirconia generations. They reported that changing yttria content had a significant impact on translucency. Different kinds of zirconia ceramics of the same generation have varying translucencies. Achieving optimum aesthetics with monolithic zirconia is challenging due to factors related to material aspects such as the presence of additives, point defects, microstructure, thickness, phase distribution, and sintering conditions. CONCLUSIONS: Newly developed monolithic dental zirconia ceramics have improved aesthetics and translucency. However, additional research is necessary to evaluate their performance and long-term durability. TRIAL REGISTRATION: This systematic review was registered in PROSPERO, under number CRD42023474482.


Assuntos
Cerâmica , Idioma , Ítrio , Zircônio , Prostodontia
3.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 42(1): 62-66, 2024 Feb 01.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-38475952

RESUMO

OBJECTIVES: This work aimed to evaluate the effect of speed sintering and low-temperature degradation on the translucency of high-translucent zirconia. METHODS: The ST and TT specimens were randomly divided into two groups depending on the sintering process: conventional sintering and speed sintering. The sintered specimens were divided into three subgroups according to the aging time: aged for 0, 5, and 20 h. Chromatic parameters (L*, a*, and b* values) were measured by Shade Eye NCC computer colorimeter in a dark environment under black and white background, and the translucency parameter (TP) was used to evaluate the translucency of zirconia. RESULTS: Speed sintering may decrease the TP of ST and increase the TP of TT. As for the effect of low-temperature degradation on the translucency of zirconia, the TP of ST decreased with the extension of aging time, and no significant difference was found in rapid sintering ST. Although the TP of TT decreased, no statistical difference was observed. CONCLUSIONS: Speed sintering may decrease the translucency of high-strength zirconia and increase the translucency of high-translucent zirconia. Low-temperature degradation had no effect on the translucency of high-translucent zirconia. Speed sintering can be recommended for high-translucent zirconia in terms of translucency.


Assuntos
Cerâmica , Materiais Dentários , Teste de Materiais , Propriedades de Superfície , Zircônio
4.
Dent Mater J ; 43(2): 216-226, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38417860

RESUMO

This study aimed to investigate the effects of sandblasting on the physical properties and bond strength of two types of translucent zirconia: niobium-oxide-containing yttria-stabilized tetragonal zirconia polycrystals ((Y, Nb)-TZP) and 5 mol% yttria-partially stabilized zirconia (5Y-PSZ). Fully sintered disc specimens were either sandblasted with 125 µm alumina particles or left as-sintered. Surface roughness, crystal phase compositions, and surface morphology were explored. Biaxial flexural strength (n=10) and shear bond strength (SBS) (n=12) were evaluated, including thermocycling conditions. Results indicated a decrease in flexural strength of 5Y-PSZ from 601 to 303 MPa upon sandblasting, while (Y, Nb)-TZP improved from 458 to 544 MPa. Both materials significantly increased SBS after sandblasting (p<0.001). After thermocycling, (Y, Nb)-TZP maintained superior SBS (14.3 MPa) compared to 5Y-PSZ (11.3 MPa) (p<0.001). The study concludes that (Y, Nb)-TZP is preferable for sandblasting applications, particularly for achieving durable bonding without compromising flexural strength.


Assuntos
Materiais Dentários , Nióbio , Óxidos , Materiais Dentários/química , Teste de Materiais , Propriedades de Superfície , Zircônio/química , Ítrio/química , Óxido de Alumínio , Resistência ao Cisalhamento
5.
Heliyon ; 10(1): e23283, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38205291

RESUMO

Objectives: To investigate the effect of different designs of movable parts and prosthetic materials on the stress distribution of supporting tissues in mandibular free end dentition defects using three-dimensional finite element analysis of digital Roach attachments. Material and methods: A 3D model of a patient with Kennedy class I mandibular edentulous conditions was generated, and twelve prosthesis models were applied, combining two designs of removable parts and six types of CAD/CAM restorative materials with different elastic modulus (conventional zirconia, ultra-translucent zirconia, Polyetheretherketone (PEEK), Lithium disilicate, Nanoceramic resin, and resin composite (Paradigm MZ100, 3 M ESPE)). The stress distribution of abutment periodontal ligament, edentulousmucosa, and junction of attachment were analyzed using finite element analysis. Results: The stress value of the buccal neck of the periodontal ligament and the maximum compressive stress of the distal periodontal ligament of the design with clasp arms were higher than those without clasp arms, while the stress on the junction of attachment and the displacement of the mucosa in the edentulous area were smaller. Restorative materials with high elastic modulus, such as conventional zirconia and ultra-translucent zirconia, are recommended to be used as the fixed part of Roach attachment. Conclusion: CAD/CAM Roach attachments with clasp arms are recommended for the protection of mucosal soft tissue. Restorative materials with high elastic modulus, such as conventional zirconia and ultra-translucent zirconia, are recommended as the fixed part of Roach attachment for patients with free end defect of mandibular dentition. Clinical significance: This study provides references for the design with clasp arms and the selection of clinical fixed-movable prosthetic materials. Clinicians should consider the design of attachments and selection of appropriate manufacturing materials carefully to avoid negative impacts on patients' periodontal support tissues.

6.
Clin Oral Investig ; 28(1): 94, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38221600

RESUMO

OBJECTIVES: The aim of this study was to compare failure load and initial damage in monolithic, partially veneered, and completely veneered (translucent) zirconia cantilevered fixed partial dentures (CFPDs), as well as completely veneered metal-ceramic CFPDs under different support and loading configurations. MATERIALS AND METHODS: Eight test groups with anatomically congruent CFPDs (n = 8/group) were fabricated, differing in CFPD material/support structure/loading direction (load applied via steel ball (Ø 6 mm) 3 mm from the distal end of the pontic for axial loading with a 2-point contact on the inner cusp ridges of the buccal and oral cusps and 1.3 mm below the oral cusp tip for 30° oblique loading): (1) monolithic zirconia/CoCr abutment teeth/axial, (2) monolithic zirconia/CoCr abutment teeth/oblique, (3) partially veneered zirconia/CoCr abutment teeth/axial, (4) partially veneered zirconia/CoCr abutment teeth/oblique, (5) completely veneered zirconia/CoCr abutment teeth/axial, (6) completely veneered CoCr/CoCr abutment teeth/axial (control group), (7) partially veneered zirconia/implants/axial, and (8) partially veneered zirconia/natural teeth/axial. Restorations were artificially aged before failure testing. Statistical analysis was conducted using one-way ANOVA and Tukey post hoc tests. RESULTS: Mean failure loads ranged from 392 N (group 8) to 1181 N (group 1). Axially loaded monolithic zirconia CFPDs (group 1) and controls (group 6) showed significantly higher failure loads. Oblique loading significantly reduced failure loads for monolithic zirconia CFPDs (group 2). Initial damage was observed in all groups except monolithic zirconia groups, and fractography revealed design flaws (sharp edges at the occlusal boundary of the veneering window) in partially veneered zirconia CFPDs. CONCLUSIONS: Monolithic zirconia CFPDs might be a viable alternative to completely veneered CoCr CFPDs in terms of fracture load. However, oblique loading of monolithic zirconia CFPDs should be avoided in clinical scenarios. Design improvements are required for partially veneered zirconia CFPDs to enhance their load-bearing capacity. CLINICAL RELEVANCE: Monolithic zirconia may represent a viable all-ceramic alternative to the established metal-ceramic option for CFPD fabrication. However, in daily clinical practice, careful occlusal adjustment and regular monitoring should ensure that oblique loading of the cantilever is avoided.


Assuntos
Cerâmica , Falha de Restauração Dentária , Zircônio , Prótese Parcial Fixa , Porcelana Dentária , Teste de Materiais , Análise do Estresse Dentário , Coroas
7.
J Prosthodont ; 33(4): 358-366, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37114526

RESUMO

PURPOSE: To compare the fracture resistance and failure modes of anterior cantilever resin-bonded fixed partial dentures (RBFPDs) fabricated from high translucency zirconia with different intaglio surface treatments. MATERIALS AND METHODS: Sound-extracted canines (N = 50) were randomly divided into five groups (n = 10) to be restored with high translucency zirconia RBFBDs of different intaglio surface treatments. The RBFPD was designed using exocad software and fabricated using a CAM milling machine. The RBFPDs were treated differently: abrasion with 50 µm alumina particles (Group 1); abrasion with 30 µm silica-coated alumina particles (Group 2); abrasion with silica-coated alumina particles (30 µm) and silane application (Group 3); abrasion with silica-coated alumina particles (30 µm) and 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) primer application (Group 4); abrasion with silica-coated alumina particles (30 µm) and silane, and 10-MDP primer application. All RBFPDs were cemented using dual-cured resin cement. The RBFPDs underwent 6000 thermal cycles with distilled water at 5/55°C for 2 min per cycle and then mechanical cyclic loading with 1200,000 cycles of 50 N at a 1.7 Hz frequency at an angle of 135° to the abutment's long axis. Then, RBFPDs were loaded to fracture using a universal testing machine at 1 mm/min. Maximum fracture forces and failure modes were recorded. Fractured specimens and uncemented specimens were examined using a scanning electron microscope. Data was analyzed using ANOVA and Games-Howell post hoc tests at p < 0.05. RESULTS: Mean fracture load results showed a statistically significant difference between the research groups (p < 0.0001) and it ranged from 69.78 to 584 N. Group 4 exhibited the highest fracture load mean (p < 0.0001) which was significantly different from all other groups. Group 2 recorded a significantly higher fracture load mean than Group 3 (p = 0.029). Three modes of failure were observed: prosthesis debonding, prosthesis fracture, and abutment fracture. CONCLUSIONS: Abrasion of zirconia surface with 30 µm silica-coated alumina particles and application of 10-MDP primer yielded the highest mean fracture loads of monolithic high translucency zirconia RBFPD. The mode of fracture of the RBFPDs was influenced by the type of surface treatments.


Assuntos
Colagem Dentária , Prótese Adesiva , Metacrilatos , Resistência à Flexão , Silanos , Teste de Materiais , Cimentos de Resina , Zircônio , Dióxido de Silício , Óxido de Alumínio , Propriedades de Superfície , Análise do Estresse Dentário/métodos
8.
Int Orthod ; 22(1): 100822, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37992472

RESUMO

PURPOSE: The objective of this study was to compare the shear bond strengths of orthodontic brackets bonded to translucent dental zirconia samples which are anatomically accurate and treated with various surface treatments. METHODS: This in vitro study included 156 samples from 3 brands of high-translucent zirconia split into a control group and 4 surface treatment groups: 9.6% hydrofluoric acid etching, 50-micron aluminium oxide particle air abrasion, and 30-micron tribochemical silica coating (TBS) particle air abrasion with and without silane application. After surface treatment, all groups were primed with a 10-MDP primer and bonded to metal orthodontic brackets. Shear bond strength (SBS) was tested and results were compared between all groups. Data analysis consisted of a balanced two-factor factorial ANOVA, a Shapiro-Wilks test, and a non-parametric permutation test. The significance level was set at 0.05. RESULTS: Among all surface treatments, aluminium oxide particle abrasion produced significantly higher SBS (P≤0.002). Lava™ Plus zirconia samples had significantly higher SBS than Cercon® samples (P<0.0001). TBS surface treatment produced significantly higher SBS on Lava™ Plus samples than it did on the other zirconia brands (P=0.032). CONCLUSIONS: This study indicated that mechanical abrasion using aluminium oxide in combination with a 10-MDP primer creates a higher SBS to high-translucent zirconia than the bond created by tribochemical silica coating. Also, there was no significant difference in ARI regardless of zirconia brand or surface preparation.


Assuntos
Colagem Dentária , Metacrilatos , Braquetes Ortodônticos , Zircônio , Humanos , Cimentos de Resina/química , Abrasão Dental por Ar , Propriedades de Superfície , Resistência ao Cisalhamento , Dióxido de Silício/química , Óxido de Alumínio/química , Teste de Materiais , Análise do Estresse Dentário
9.
Biomedicines ; 11(12)2023 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-38137337

RESUMO

Over the past two decades, dental ceramics have experienced rapid advances in science and technology, becoming the fastest-growing field of dental materials. This review emphasizes the significant impact of translucent zirconia in fixed prosthodontics, merging aesthetics with strength, and highlights its versatility from single crowns to complex bridgework facilitated by digital manufacturing advancements. The unique light-conducting properties of translucent zirconia offer a natural dental appearance, though with considerations regarding strength trade-offs compared to its traditional, opaque counterpart. The analysis extends to the mechanical attributes of the material, noting its commendable fracture resistance and durability, even under simulated physiological conditions. Various zirconia types (3Y-TZP, 4Y-TZP, 5Y-TZP) display a range of strengths influenced by factors like yttria content and manufacturing processes. The study also explores adhesive strategies, underlining the importance of surface treatments and modern adhesives in achieving long-lasting bonds. In the realm of implant-supported restorations, translucent zirconia stands out for its precision, reliability, and aesthetic adaptability, proving suitable for comprehensive dental restorations. Despite its established benefits, the review calls for ongoing research to further refine the material's properties and adhesive protocols and to solidify its applicability through long-term clinical evaluations, ensuring its sustainable future in dental restorative applications.

10.
J Adhes Dent ; 25(1): 219-230, 2023 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-37910068

RESUMO

PURPOSE: The first objective was to determine if dual-curing of resin cement with reduced light could affect interfacial adaptations of zirconia restoration. The second objective was to examine whether cement type and pretreatment method of universal adhesive affected interfacial adaptation. The final objective was to compare the polymerization degree of cement under different reduced-light conditions. MATERIALS AND METHODS: Inlay cavities were prepared on extracted third molars. Translucent zirconia restorations were milled using Katana UTML (Kuraray Noritake) in three groups with restoration thicknesses of 1, 2, and 3 mm, respectively. Each group had three subgroups using different cementation methods. For subgroup 1, restorations were cemented with self-adhesive cement. For subgroup 2, universal adhesive was applied and light cured. After the restoration was seated with conventional resin cement, light curing was performed. For subgroup 3, after adhesive was applied, the restoration was seated with conventional resin cement. Light curing was performed for the adhesive and cement simultaneously. After thermocycling, interfacial adaptation at the restoration-tooth interface was investigated using swept-source optical coherence tomography imaging. Finally, polymerization shrinkage of the cement was measured using a linometer and compared under the conditions of different zirconia thicknesses and light-curing durations. RESULTS: Interfacial adaptation varied signficantly depending on the zirconia thickness, pretreatment, polymerization mode and cements used (p < 0.05). The effects of the adhesive and polymerization shrinkage differed signficantly, depending on the reduced light under the zirconia (p < 0.05). CONCLUSION: Lower curing-light irradiance may lead to inferior adaptation and lower polymerization of the cement. Polymerization of resin cement can differ depending on the light irradiance and exposure duration.


Assuntos
Cimentos Dentários , Cimentos de Resina , Polimerização , Cimentos de Ionômeros de Vidro
11.
Dent Mater ; 39(12): 1169-1179, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37845165

RESUMO

OBJECTIVES: To evaluate the impact of speed sintering on the microstructure and optical properties of 3 and 5 mol% yttria-partially stabilized monolithic zirconias. METHODS: 120 plate-shaped zirconia specimens (10x10x 0.4 mm) were prepared from three commercial 5 mol% yttria-partially stabilized zirconia blocks (5Y-PSZs); Katana UTML (Kuraray Noritake), Cercon xtML (Dentsply Sirona), and Zolid FX white (Amann Girrbach), and two commercial 3 mol% yttria-partially stabilized zirconia blocks (3Y-PSZs); Lava Plus (3 M ESPE) and InCoris (Sirona, GmbH). Specimens were either conventional sintered (CS) using a 7-hour program or speed sintered (SS) using a quick 90-minute program. The microstructure was inspected with a scanning electron microscope (SEM), and phase fractions were detected using x-ray diffraction analysis (XRD). Translucency (TP00), and contrast ratio (CR) were obtained using a spectrophotometer (VITA Easyshade V). Color difference (ΔE00) between both sintering processes was calculated with the CIEDE2000 formula. ΔE00 up to 1.8 was set as the acceptability threshold. Data were analyzed using two-way ANOVA, Krusakll-Wallis, and Mann-Whitney U tests. (n = 12, α = .05). RESULTS: Grain size was significantly decreased after SS for all tested materials (P < .0001). The average grain sizes of 5Y-PSZs were significantly larger than those of 3Y-PSZs. The atomic structure, microstructure, and transparency of CS and SS were all affected by the amount of yttria, the size of the crystals, and tetragonality. SS significantly reduced TP00 (F = 7135.95, P < 0.0001) and increased CR (F = 453.21, P < 0.0001). The CS Katana presented the highest TP00 and lowest CR value. ΔE00 between the CS and SS groups were clinically acceptable except for Lava, which had values above the set threshold (1.89). SIGNIFICANCE: SS altered the grain size and internal structure of the tested materials, which was reflected in translucency.


Assuntos
Materiais Dentários , Zircônio , Teste de Materiais , Ítrio , Propriedades de Superfície , Cerâmica
12.
Clin Exp Dent Res ; 9(6): 1078-1088, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37787028

RESUMO

INTRODUCTION: The rate of clinical success in veneers, under esthetics, has achieved a range of 18 months to 20 years. In a plethora of studies, it registers a success rate reaching 75% and even 100%. The most common type of glass ceramics used in ceramics is the vitreous lithium disilicate crystal-reinforced material, e.max®. Recent studies focus on "polycrystalline ceramic use" in manufacturing veneers, as it possesses a stronger structure and different enabling manufacturing schemes. OBJECTIVES: This research aims at comparing e.max and the high-translucent Cubic Zirconia. Such comparison is administered to veneers manufacturing: esthetic (surface and edge, and staining and color matching), functional (crack and fracture, contact point, and patient satisfaction), and biological (posttreatment vitality and hypersensitivity, and periodontal response). MATERIALS AND METHODS: The research sample consisted of 60 veneers, divided into two groups: cubic zirconia and e.max. The sample included 2 males (16.6%) and 10 females (83.3%), with age ranging from 25 to 37 years. Patients were thoroughly diagnosed and treated and included in this study based on certain inclusion-exclusion criteria. Hickel's 2010 criteria were utilized to examine and observe the clinical aspect of veneers during intervals of 1 week, 3 months, 1 year, and 3 years. RESULTS: No significant differences were traced across the groups for all the variables, with a p-value being greater than 0.05. The e.max group revealed better clinical results compared to the cubic zirconia one regarding esthetics and tooth translucency. Nonetheless, the results showed a merely slight increase in hypersensitivity in the e.max group. CONCLUSION: Within the limitation of an extensive follow-up period, we can conclude that there is no difference between cubic zirconia and e.max (p > 0.05), where e.max and cubic zirconia veneers have the same characteristics in terms of the following. The characteristics of the aspects examined were esthetic, functional, and biological.


Assuntos
Cerâmica , Humanos , Adulto , Teste de Materiais , Cerâmica/química
13.
BMC Oral Health ; 23(1): 636, 2023 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-37670286

RESUMO

OBJECTIVES: Successful ceramic restorations depend on the strong bonding with resin cement and even stress distribution. The aim of this study was to evaluate the impact of adding MDP-containing zirconia primer before self-adhesive resin cements with different functional acidic monomers on fracture resistance of monolithic zirconia crown. MATERIALS AND METHODS: Eighty defect-free human maxillary premolars were divided according to the cement type and application of MDP-containing zirconia primer into eight groups (n = 10): Calibra Universal (C), Calibra Universal combined with zirconia primer (CZ), RelyX U200 (R), RelyXU200 combined with zirconia primer (RZ), Panavia SA Cement Plus (P), Panavia SA Cement Plus combined with zirconia primer (PZ), Multilink Speed (M), and Multilink Speed combined with zirconia primer (MZ). After teeth preparation and fabrication of zirconia crowns, each crown was bonded to its corresponding tooth. All specimens were subjected to 10,000 thermocycles between 5 and 55°C, followed by cyclic load (50 N) for 240,000 cycles. Each specimen was subjected to a static axial load until fracture using universal testing machine and the fracture load was recorded. The fracture mode studied and recorded. The fracture load results were analyzed using two-way ANOVA test (α = 0.05). RESULTS: A significant interaction (P = 0.038) of combining MDP-containing zirconia primer and cement type on fracture resistance of monolithic zirconia crown was detected. The mean fracture load values of zirconia crown were significantly influenced by the combined application of the MDP-containing zirconia primer with Calibra Universal (P = 0.01), RelyX U200 (P < 0.001), and Multilink Speed (P = 0.038), while there was no significant difference with Panavia SA Cement Plus (P = 0.660). There was significant difference (F = 20.69, P < 0.001) between the mean fracture loads of groups with self-adhesive cements (C, R, P, and M groups). The highest fracture load was recorded with RZ group (2446.90 ± 126.72 N) while the lowest fracture load was recorded with C group (1623.18 ± 149.86 N). CONCLUSIONS: The self-adhesive resin cement with different acidic functional monomer affects the fracture resistance of monolithic zirconia crown. Application of MDP-containing primer could improve the fracture resistance of monolithic zirconia crown with most self-adhesive cements. The application of an MDP-containing primer had no impact on the fracture resistance of monolithic translucent zirconia crown bonded by MDP-containing self-adhesive resin cement.


Assuntos
Cimentos Dentários , Cimentos de Resina , Humanos , Cemento Dentário , Cimentos de Ionômeros de Vidro , Coroas
14.
J Adv Prosthodont ; 15(4): 171-178, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37662855

RESUMO

PURPOSE: The purpose of this study was to determine the effect of the connector configuration on the fracture load in conventional and translucent zirconia of three-unit fixed dental prostheses (FDPs). MATERIALS AND METHODS: Six different three-unit FDPs were prepared (n = 6) from three types of zirconia (3Y-TZP (Katana ML®), 4Y-TZP (Katana STML®), and 5Y-TZP (Katana UTML®)) in combination with two connector configurations (4 × 2.25, 3 × 3 mm). The Co-Cr master models were scanned, and the FDPs were designed and fabricated using CAD-CAM. The FDPs were cemented on the metal model and then loaded with a UTM at a crosshead speed of 1 mm/min until failure. Two-way ANOVA and Tukey's test were used for statistical analysis (α = .05). RESULTS: Fracture loads of 3Y-TZP (2740.6 ± 469.2 and 2718.7 ± 339.0 N for size 4 × 2.25 mm and 3 × 3 mm, respectively) were significantly higher than those of 4Y-TZP (1868.3 ± 281.6 and 1663.6 ± 372.7 N, respectively) and 5Y-TZP (1588.0 ± 255.0 and 1559.1 ± 110.0 N, respectively) (P < .05). No significant difference was found between fracture loads of 4Y-TZP and 5Y-TZP (P > .05). The connector configuration within 9 mm2 was found to have no effect on the fracture loads on all three types of zirconia (P > .05). CONCLUSION: Fracture loads of three-unit FDPs were affected by the type of zirconia. The fracture loads of conventional zirconia were higher than those of translucent zirconia. However, it was not affected by the connector configuration when the connector had a cross-sectional area of 9 mm2.

15.
Artif Cells Nanomed Biotechnol ; 51(1): 441-452, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37594201

RESUMO

High translucent zirconia (HTZ) has excellent mechanical properties, biocompatibility, and good semi-translucency making it an ideal material for aesthetic anterior dental implant abutments without antibacterial properties. In the oral environment, the surface of the abutment material is susceptible to microbial adhesion and biofilm formation, which can lead to infection or peri-implantitis and even implant failure. This study aims to promote the formation of a biological seal at the implant-soft tissue interface by modifying the HTZ surface, using the load-bearing capacity of the aluminosilicate porous structure and the broad-spectrum antibacterial effect of silver nanoparticles to prevent peri-implant bacterial infection and inflammation and to improve the success rate and prolong the use of the implant. FE-SEM (field emission scanning electron microscopes), EDS (energy dispersive spectroscopy), and XPS (X-ray photoelectron spectroscopy) results showed that aluminosilicate non-vacuum sintering can form open micro- and nanoporous structures on HTZ surfaces, and that porous aluminosilicate coatings obtain a larger number, smaller size, and more uniformly shaped silver nanoparticles than smooth aluminosilicate coatings, and could be deposited deeper in the coating. The ICP-AES (inductively coupled plasma-atomic emission spectroscopy) results showed that the early silver ion release of both the smooth silver coating and the porous silver coating was obvious, the silver ion concentration released by the former was higher than that of the latter. However, the silver ion concentration released by the porous silver coating was higher than that of the smooth coating when the release slowed down. Both smooth and porous silver coatings both inhibited E. coli (Escherichia coli), S. aureus (Staphylococcus aureus), and L. acidophilus (L. acidophilus), and porous silver coatings had stronger antibacterial properties. The silver coating was successfully constructed on the surface of HTZ, through aluminium silicate sintering and silver nitrate solution impregnation. It was found that the high concentration environment of silver nitrate solution was more advantageous for nano-Ag deposition, and the non-vacuum sintered porous surface was able to obtain a larger number of nano-Ag particles with smaller sizes. The porous Ag coating exhibited superior antibacterial properties. It was suggested that the HTZ with silver coating had clinical application, and good antibacterial properties that can improve the survival rate and service life of implants.


Assuntos
Escherichia coli , Nanopartículas Metálicas , Prata/farmacologia , Nitrato de Prata , Staphylococcus aureus , Antibacterianos/farmacologia
16.
Cureus ; 15(3): e36958, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37009356

RESUMO

Objective The purpose of this in vitro study is to compare the flexural strength and Weibull modulus of 5 different monolithic computer-aided design/computer-aided manufacturing (CAD/CAM) ceramics. Methods A total of 50 specimens were fabricated, 10 from each of the following materials: lithium disilicate-based ceramic (IPS e.max CAD), zirconia -reinforced lithium-silicate ceramic (Vita Suprinity), leucite-based glass ceramic (IPS Empress CAD), and two zirconia-based ceramics (Zenostar and CopraSmile). The specimens were 4 mm wide, 2 mm thick, and 16 mm long. Flexural strength test was executed using a universal testing machine (Model 5980, Instron Industrial Products, Norwood, MA, USA). The two-parameter Weibull distribution function was used to analyze the variability of flexural strength values. Statistical analysis was performed on SPSS Version 23 (IBM Corp., Armonk, NY, USA) using one-way analysis of variance (ANOVA) and post-hoc Tukey's test. Results Suprinity had the highest Weibull modulus value, while Empress CAD displayed the lowest value. One-way ANOVA showed significant difference in the flexural strength between the different materials tested (p<0.05). Post-hoc analysis revealed significant differences among all the test groups in terms of flexural strength. Zenostar presented the highest mean flexural strength value (1033.90 MPa), while Empress CAD had the lowest value. Conclusion High-translucency zirconia had superior flexural properties than translucent zirconia, lithium disilicate ceramics, zirconia-reinforced lithium silicate ceramics, and leucite-based glass ceramics.

17.
J Funct Biomater ; 14(2)2023 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-36826868

RESUMO

(1) Background: Considering that the appearance of a dental material is an important factor that contributes to the success of prosthetic restorations. The purpose of this study is to investigate the optical properties and color changes among the layers of three commercial zirconias, to compare the aspect of the polished and glazed surfaces before and after aging and to evaluate the effects of hydrothermal degradation on their aesthetics. (2) Methods: Forty-eight plate-shaped samples were sectioned from presintered blocks of each multilayer translucent zirconia with different Yttrium content: Ceramill Zolid fx ML (5 mol%) = CeZ, STML (4 mol%) = STM, IPS e.maxZirCAD CEREC/in Lab MT Multi (4 mol% + 5 mol%) = IPZ. The samples were sintered according to the recommendation of each manufacturer, and half (24) of them were polished and the other half (24) glazed on one of the surfaces. Each type was equally divided into one control and one aging group, and, for each material, this resulted in four groups (n = 12): polished-control, polished-autoclaved glazed-control, and glazed-autoclaved. The artificial aging was carried out with an autoclave and distilled water at 134 °C, 0.2 MPa for 1 h, and for optical parameters (TP, CR, OP) and color change (ΔE*) measurements on a black and white background in a CIE L*a*b* color system, a spectrophotometer was used. The specimens were evaluated in incisal, cervical, and medium areas on polished and glazed samples before and after the aging stage. Statistical analysis was achieved with a two-way ANOVA test, the unpaired t-test, and the paired t-test. (3) Results: Before and after aging, the mean TP values for polished samples were higher than the glazed ones. After aging, the mean TP values increased for all groups (except polished CeZ), and significant differences were reported for polished STM, IPZ. After LTD, the opalescence registered an increase for almost all groups (except polished CeZ, polished and glazed IPZ-medium area), and significant differences were reported for almost all groups (except STM-incisal, IPZ-cervical, medium areas). The levels of color change were between extremely slight to perceivable. (4) Conclusions: Optical properties of the selected multilayer zirconia were influenced by polishing and glazing as surface treatment and affected by artificial aging (CeZ the least); perceivable color changes for polished STM, IPZ were detected.

18.
Dent Mater J ; 42(1): 1-10, 2023 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-36631076

RESUMO

This review describes the development of ultra-high translucent zirconia (referred to as UHTZ) using new manufacturing technology and its characterization results. The development of UHTZ was primarily due to the adoption of two basic manufacturing technologies, "Cyclic CIP" and "Plus Y Technology". This manufacturing technology could provide stable processing characteristics, which improves chipping resistance during milling. Furthermore, the enlargement factor (processing coefficient) for UHTZ is smaller than those for conventional products. In general, the higher the light transmittance, the lower the flexural strength. Despite its extremely high translucency, the most significant feature of UTHZ is that its flexural strength is comparable to that of 5Y. Furthermore, UHTZ has higher chemical durability and uniform microstructure, which results in less wear on the opposing teeth and superior discoloration resistance. Therefore, UHTZ is a new option for inlay, onlay, and laminate veneer applications, where lithium disilicate glass ceramics has been widely used.


Assuntos
Cerâmica , Porcelana Dentária , Teste de Materiais , Porcelana Dentária/química , Cerâmica/química , Zircônio/química , Resistência à Flexão , Propriedades de Superfície
19.
Clin Oral Investig ; 27(6): 2653-2665, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36574045

RESUMO

OBJECTIVES: To evaluate and compare fracture resistance, translucency, and color reproducibility, as well as the effect of aging on the fracture load and color stability of novel monolithic CAD/CAM ceramics. MATERIALS AND METHODS: One hundred crowns of uniform thickness were milled from five ceramic blocks (n = 20): partially crystallized lithium disilicate (PLD) and fully crystallized lithium disilicate (FLD), lithium metasilicate (LMS), 4Y-TZP (SMZ), and 5Y-TZP (UMZ) monolithic zirconia. PLD crowns were glazed, LMS was fired, and FLD was polished. SMZ and UMZ crowns were sintered and polished. Crowns were adhesively cemented to epoxy dies. Half of the crowns (n = 10) were subjected to 1.200.000 load cycles with thermal cycling. Color space values L, a, b defined by the Commission Internationale de l´Eclairage (CIELAB) were measured before and after aging, and (∆E) was calculated. Both aged and non-aged specimens were loaded until fracture in a universal testing machine and the fracture load was recorded. X-ray diffraction (XRD) and scanning electron microscope (SEM) fractographic analysis were carried out on fractured fragments of representative samples. For translucency and color reproducibility, 50 rectangular-shaped specimens were fabricated and processed as described previously. Color values were measured over black and white backgrounds, and the translucency parameter (TP) was computed. Using the shade verification mode, (∆E) to shade A3 was calculated. Data were statistically analyzed using one-way and two-way ANOVA, and t-test. RESULTS: Aging did not affect fracture resistance significantly (p > 0.05). The highest mean fracture load was obtained for the SMZ and UMZ. A significant color change was observed after aging in all groups. The highest TP was noted for FLD. SMZ and UMZ had the best shade match. CONCLUSIONS: Zirconia showed higher fracture resistance and color stability than lithium silicate ceramics. Lithium silicate ceramics were more translucent. The experimental FLD demonstrated high translucency. CLINICAL RELEVANCE: Tested ceramics showed sufficient stability to withstand masticatory forces. Characterization of final restorations might be mandatory for better color match.


Assuntos
Estética Dentária , Lítio , Humanos , Cerâmica , Cor , Desenho Assistido por Computador , Coroas , Porcelana Dentária , Análise do Estresse Dentário , Teste de Materiais , Reprodutibilidade dos Testes , Silicatos , Propriedades de Superfície , Zircônio
20.
J Adv Prosthodont ; 14(5): 324-333, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36452362

RESUMO

PURPOSE: The purpose of this study is to evaluate translucency and masking ability of translucent zirconia compared to conventional zirconia and lithium disilicate materials. MATERIALS AND METHODS: Three types of zirconia blocks with different yttria contents (3Y, 4Y, 5.5Y) and LS blocks (Rosetta SM) were used. Ten specimens for each group were fabricated with 10 mm diameter, with both 0.8 mm and 1.5 mm thicknesses (± 0.02 mm). All groups of zirconia specimens were sintered and polished according to the manufacturer's instructions. To calculate the translucency parameter (TP), CIELAB value was measured with a spectrophotometer on black and white backgrounds. To investigate the color masking abilities, background shades of A2, normal dentin, discolored dentin, and titanium were used. The color difference (ΔE) was calculated with the CIELAB values of A2 shade background as a reference compared with the values in the various backgrounds. One-way ANOVA and Bonferroni tests were conducted (P < .05). RESULTS: The TP values of zirconia specimens increased as the yttria content increased. All materials used in the study were able to adequately mask normal dentin shade (ΔE < 5.5), but were incapable of masking severely discolored dentin (ΔE > 5.5). On the titanium background, all materials of 1.5 mm thickness were able to mask the background shade, but with a thickness of 0.8 mm, only 3Y-TZP and 4Y-PSZ were able to mask titanium background. CONCLUSION: All zirconia materials and lithium disilicate specimens used in this study were unable to adequately mask the shade of severely discolored dentin. It is recommended to use 3Y-TZP or 4Y-PSZ with a sufficient thickness of 0.8 mm or more to mask titanium.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...