Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(7)2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38610371

RESUMO

Dielectric characterization is extremely promising in medical contexts because it offers insights into the electromagnetic properties of biological tissues for the diagnosis of tumor diseases. This study introduces a promising approach to improve accuracy in the dielectric characterization of millimeter-sized biopsies based on the use of a customized electromagnetic characterization system by adopting a coated open-ended coaxial probe. Our approach aims to accelerate biopsy analysis without sample manipulation. Through comprehensive numerical simulations and experiments, we evaluated the effectiveness of a metal-coating system in comparison to a dielectric coating with the aim for replicating a real scenario: the use of a needle biopsy core with the tissue inside. The numerical analyses highlighted a substantial improvement in the reconstruction of the dielectric properties, particularly in managing the electric field distribution and mitigating fringing field effects. Experimental validation using bovine liver samples revealed highly accurate measurements, particularly in the real part of the permittivity, showing errors lower than 1% compared to the existing literature data. These results represent a significant advancement for the dielectric characterization of biopsy specimens in a rapid, precise, and non-invasive manner. This study underscores the robustness and reliability of our innovative approach, demonstrating the convergence of numerical analyses and empirical validation.


Assuntos
Eletricidade , Animais , Bovinos , Reprodutibilidade dos Testes , Biópsia
2.
Adv Mater ; 36(25): e2307286, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38516842

RESUMO

Solid oxide fuel cells that operate at intermediate temperatures require efficient catalysts to enhance the inherently poor electrochemical activity of the composite electrodes. Here, a simple and practical electrochemical deposition method is presented for fabricating a PrOx overlayer on lanthanum strontium manganite-yttria-stabilized zirconia (LSM-YSZ) composite electrodes. The method requires less than four minutes for completion and can be carried out under at ambient temperature and pressure. Crucially, the treatment significantly improves the electrode's performance without requiring heat treatment or other supplementary processes. The PrOx-coated LSM-YSZ electrode exhibits an 89% decrease in polarization resistance at 650 °C (compared to an untreated electrode), maintaining a tenfold reduction after ≈400 h. Transmission line model analysis using impedance spectra confirms how PrOx coating improved the oxygen reduction reaction activity. Further, tests with anode-supported single cells reveal an outstanding peak power density compared to those of other LSM-YSZ-based cathodes (e.g., 418 mW cm-2 at 650 °C). Furthermore, it is demonstrated that multicomponent coating, such as (Pr,Ce)Ox, can also be obtained with this method. Overall, the observations offer a promising route for the development of high-performance solid oxide fuel cells.

3.
Bioengineering (Basel) ; 10(12)2023 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-38135934

RESUMO

In the human phonation process, acoustic standing waves in the vocal tract can influence the fluid flow through the glottis as well as vocal fold oscillation. To investigate the amount of acoustic back-coupling, the supraglottal flow field has been recorded via high-speed particle image velocimetry (PIV) in a synthetic larynx model for several configurations with different vocal tract lengths. Based on the obtained velocity fields, acoustic source terms were computed. Additionally, the sound radiation into the far field was recorded via microphone measurements and the vocal fold oscillation via high-speed camera recordings. The PIV measurements revealed that near a vocal tract resonance frequency fR, the vocal fold oscillation frequency fo (and therefore also the flow field's fundamental frequency) jumps onto fR. This is accompanied by a substantial relative increase in aeroacoustic sound generation efficiency. Furthermore, the measurements show that fo-fR-coupling increases vocal efficiency, signal-to-noise ratio, harmonics-to-noise ratio and cepstral peak prominence. At the same time, the glottal volume flow needed for stable vocal fold oscillation decreases strongly. All of this results in an improved voice quality and phonation efficiency so that a person phonating with fo-fR-coupling can phonate longer and with better voice quality.

4.
Diagnostics (Basel) ; 13(18)2023 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-37761382

RESUMO

Dielectric characterization has significant potential in several medical applications, providing valuable insights into the electromagnetic properties of biological tissues for disease diagnosis, treatment planning, and monitoring of therapeutic interventions. This work presents the use of a custom-designed electromagnetic characterization system, based on an open-ended coaxial probe, for discriminating between benign and malignant breast tissues in a clinical setting. The probe's development involved a well-balanced compromise between physical feasibility and its combined use with a reconstruction algorithm known as the virtual transmission line model (VTLM). Immediately following the biopsy procedure, the dielectric properties of the breast tissues were reconstructed, enabling tissue discrimination based on a rule-of-thumb using the obtained dielectric parameters. A comparative analysis was then performed by analyzing the outcomes of the dielectric investigation with respect to conventional histological results. The experimental procedure took place at Complejo Hospitalario Universitario de Toledo-Hospital Virgen de la Salud, Spain, where excised breast tissues were collected and subsequently analyzed using the dielectric characterization system. A comprehensive statistical evaluation of the probe's performance was carried out, obtaining a sensitivity, specificity, and accuracy of 81.6%, 61.5%, and 73.4%, respectively, compared to conventional histological assessment, considered as the gold standard in this investigation.

5.
ACS Appl Mater Interfaces ; 14(33): 38246-38254, 2022 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-35969680

RESUMO

The performance of bulk-type all-solid-state Li batteries (ASSBs) depends critically on the contacts between cathode active material (CAM) particles and solid electrolyte (SE) particles inside the composite cathodes. These contacts determine the Li+ exchange current density at the CAM | SE interfaces. Nevertheless, there is a lack of experimental studies on Li+ exchange current densities, which may be caused by the poor understanding of the impedance spectra of ASSBs. We have carried out a comparative case study using two different active materials, namely, single-crystalline LiCoO2 particles and single-crystalline LiNi0.83Mn0.06Co0.11O2 particles. Amorphous 0.67 Li3PS4 + 0.33 LiI particles act as a solid electrolyte within the cathode and separator, and lithiated indium acts as the anode. The determination of the cathode exchange current density is based on (i) impedance measurements on In-Li | SE | In-Li symmetric cells in order to determine the anode impedance together with the anode | separator interfacial impedance and (ii) variation in the composite cathode thickness in order to differentiate between the ion transport resistance and the charge transfer resistance of the composite cathode. We show that under the application of stack pressures in the range of 400 MPa, the Li+ exchange current densities can compete with or even exceed those obtained for CAM | liquid electrolyte interfaces.

6.
Micromachines (Basel) ; 13(5)2022 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-35630182

RESUMO

This paper provides a new way for spatial current/field profiles for frequency-selective surface analytical approximation. It confirms that the per unit length radiation resistance of an equivalent transmission line model for line antenna has little influence on the normalized current distribution. The two-wire equivalent transmission line model (typically used for transmitting line antenna) is applied to the receiving line antenna. In this case, the corresponding incident field is decomposed into odd and even mode for asymmetric distribution. A one-wire equivalent transmission line model is then introduced for any antenna composed of relative narrow strips. The incident field does not need to be decomposed. According to the simulation, the transmission line loss has little influence on the current distribution.

7.
Micromachines (Basel) ; 13(5)2022 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-35630211

RESUMO

In this work, an mm-wave/THz MEMS switch design process is presented. The challenges and solutions associated with the switch electrical design, modeling, fabrication, and test are explored and discussed. To investigate the feasibility of this design process, the switches are designed on both silicon and fused quartz substrate and then tested in the 140-750 GHz frequency range. The measurement fits design expectations and simulation well. At 750 GHz the measurement results from switches on both substrates have an ON state insertion loss of less than 3 dB and an OFF state isolation larger than 12 dB.

8.
Micromachines (Basel) ; 13(5)2022 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-35630258

RESUMO

A side ohmic contact mode for the double channel GaN/AlGaN epitaxial layer is proposed in this paper. Rectangle transmission line model (TLM) electrodes are prepared, and the specific contact resistance is tested at the annealing temperatures from 700 °C to 850 °C. The results show that the minimum specific contact resistance is 2.58 × 10-7 Ω·cm2 at the annealing temperature of 750 °C, which is three to four times lower than the surface contact mode. Scanning electron microscope (SEM), energy dispersive spectrometer (EDS), and atomic force microscope (AFM) were carried out for the analysis of the morphology, element composition, and the height fluctuation at the contact edge. With the increase in the annealing temperature, the specific contact resistance decreases due to the alloying of electrodes and the raised number of N vacancies. However, when the annealing temperature exceeds 800 °C, the state of the stress in the electrode films transforms from compressive stress to tensile stress. Besides, the volume expansion of metal electrode film and the increase in the roughness at the contact edge leads to the degradation of the side ohmic contact characteristics.

9.
Biosensors (Basel) ; 12(2)2022 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-35200322

RESUMO

Love wave (L-SAW) sensors have been used to probe cell monolayers, but their application to detect changes beyond the focal adhesion points on cell monolayers, as viscosity changes on the cytoskeleton, has not been explored. In this work we present for the first time a Love wave sensor with tuned penetration depth and sensitivity to potentially detect mechanical changes beyond focal adhesion points of cell monolayers. We designed and fabricated a Love wave sensor operating at 30 MHz with sensitivity to detect viscous changes between 0.89 and 3.3 cP. The Love wave sensor was modeled using an acoustic transmission line model, whereas the response of interdigital transducers (IDTs) was modeled with the Campbell's cross-field circuit model. Our design uses a substrate with a high electromechanical coupling coefficient (LiNbO3 36Y-X), and an 8-µm polymeric guiding layer (SU-8). The design aims to overcome the high insertion losses of viscous liquid environments, and the loss of sensitivity due to the low frequency. The fabricated sensor was tested in a fluidic chamber glued directly to the SU-8 guiding layer. Our experiments with liquids of viscosity similar to those expected in cell monolayers showed a measurable sensor response. In addition, experimentation with SaOs-2 cells within a culture medium showed measurable responses. These results can be of interest for the development of novel cell-based biosensors, and novel characterization tools for cell monolayers.


Assuntos
Acústica , Técnicas Biossensoriais , Técnicas Biossensoriais/métodos , Adesão Celular/fisiologia , Transdutores , Viscosidade
10.
Nanomaterials (Basel) ; 12(2)2022 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-35055225

RESUMO

The electrical properties of polycrystalline graphene grown by chemical vapor deposition (CVD) are determined by grain-related parameters-average grain size, single-crystalline grain sheet resistance, and grain boundary (GB) resistivity. However, extracting these parameters still remains challenging because of the difficulty in observing graphene GBs and decoupling the grain sheet resistance and GB resistivity. In this work, we developed an electrical characterization method that can extract the average grain size, single-crystalline grain sheet resistance, and GB resistivity simultaneously. We observed that the material property, graphene sheet resistance, could depend on the device dimension and developed an analytical resistance model based on the cumulative distribution function of the gamma distribution, explaining the effect of the GB density and distribution in the graphene channel. We applied this model to CVD-grown monolayer graphene by characterizing transmission-line model patterns and simultaneously extracted the average grain size (~5.95 µm), single-crystalline grain sheet resistance (~321 Ω/sq), and GB resistivity (~18.16 kΩ-µm) of the CVD-graphene layer. The extracted values agreed well with those obtained from scanning electron microscopy images of ultraviolet/ozone-treated GBs and the electrical characterization of graphene devices with sub-micrometer channel lengths.

11.
Appl Phys A Mater Sci Process ; 127(11): 870, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34720447

RESUMO

The electrical and optical properties of Ag/p-GaN contacts have been investigated as a function of the annealing temperature, oxygen concentration, and annealing time. Specific contact resistance (ρ c) values as low as 1.2 × 10-4 Ω·cm2 were obtained from the Ag/p-GaN contact annealed at 400 °C for 60 s in ambient O2/N2 (1:10). We found that the participation of oxygen improves the formation of ohmic contacts. Oxygen might remove the H in Mg-H complexes to activate the Mg acceptors and enhance Ga out-diffusion to form an Ag-Ga solid solution. We also found that the reflectivity of the Ag layer decreases with increasing annealing temperature in the O2-containing ambient environment. Thus, an optimal annealing condition of Ag/p-GaN for blue and green LEDs is suggested based on these results. We also used the suggested annealing conditions to form ohmic contacts on DUV LEDs and achieved good electrical performance. The forward voltages of UVC LEDs fabricated with annealed Ag contacts were 6.60 V (7.66 V) at a 40 mA (100 mA) injection current.

12.
Materials (Basel) ; 14(19)2021 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-34639986

RESUMO

This work presents a comparison of values of the contact resistivity of silicon solar cells obtained using the following methods: the transmission line model method (TLM) and the potential difference method (PD). Investigations were performed with two independent scientific units. The samples were manufactured with silver front electrodes. The co-firing process was performed in an infrared belt furnace in a temperature range of 840 to 960 °C. The electrical properties of a batch of solar cells fabricated in two cycles were investigated. This work focuses on the different metallisation temperatures of co-firing solar cells and measurements were carried out using the methods mentioned. In the TLM and PD methods, the same calculation formulae were used. Moreover, solar cell parameters measured with these methods had the same, similar, or sometimes different but strongly correlated values. Based on an analysis of the selected databases, this article diagnoses the recent and current state of knowledge regarding the employment of the TLM and PD methods and the available hardware base. These methods are of interest to various research centres, groups of specialists dealing with the optimisation of the electrical properties of silicon photovoltaic cells, and designers of measuring instruments.

13.
ACS Appl Mater Interfaces ; 13(30): 36062-36070, 2021 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-34309375

RESUMO

Accurate wireless strain monitoring is critical for many engineering applications. Capacitive strain sensors are well suited for remote sensing but currently have a limited sensitivity. This study presents a new approach for improving the sensitivity of electrical capacitance change-based strain sensors. Our technology is based on a dielectric elastomer layer laminated between two fragmented electrodes (i.e., carbon nanotube papers) that, by design, experiences a significant change in resistance (from Ω to MΩ) when stretched and makes the sensor behave as a transmission line, a well-known structure in telecommunication engineering. The strain-dependent voltage attenuation over the structure length results in a large variation of the effective capacitance (gauge factor exceeding 37 at 3% strain).

14.
Am J Physiol Heart Circ Physiol ; 314(3): H443-H451, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-29101182

RESUMO

Arterial wave reflection has been shown to have a significant dependence on heart rate (HR). However, the underlying mechanisms inherent in the HR dependency of wave reflection have not been well established. This study aimed to investigate the potential mechanisms and role of arterial viscoelasticity using a 55-segment transmission line model of the human arterial tree combined with a fractional viscoelastic model. At varying degrees of viscoelasticity modeled as fractional order parameter α, reflection magnitude (RM), reflection index (RI), augmentation index (AIx), and a proposed novel normalized reflection coefficient (Γnorm) were estimated at different HRs from 60 to 100 beats/min with a constant mean flow of 70 ml/s. RM, RI, AIx, and Γnorm at the ascending aorta decreased linearly with increasing HR at all degrees of viscoelasticity. The means ± SD of the HR dependencies of RM, RI, AIx, and Γnorm were -0.042 ± 0.004, -0.018 ± 0.001, -1.93 ± 0.55%, and -0.037 ± 0.002 per 10 beats/min, respectively. There was a significant and nonlinear reduction in RM, RI, and Γnorm with increasing α at all HRs. In addition, HR and α have a more pronounced effect on wave reflection at the aorta than at peripheral arteries. The potential mechanism of the HR dependency of wave reflection was explained by the inverse dependency of the reflection coefficient on frequency, with the harmonics of the pulse waveform moving toward higher frequencies with increasing HR. This HR dependency can be modulated by arterial viscoelasticity. NEW & NOTEWORTHY This in silico study addressed the underlying mechanisms of how heart rate influences arterial wave reflection based on a transmission line model and elucidated the role of arterial viscoelasticity in the dependency of arterial wave reflection on heart rate. This study provides insights into wave reflection as a frequency-dependent phenomenon and demonstrates the validity of using reflection magnitude and reflection index as wave reflection indexes.


Assuntos
Aorta/fisiologia , Simulação por Computador , Frequência Cardíaca , Modelos Cardiovasculares , Análise Numérica Assistida por Computador , Análise de Onda de Pulso , Rigidez Vascular , Elasticidade , Humanos , Fatores de Tempo
15.
Sensors (Basel) ; 17(9)2017 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-28841146

RESUMO

Phononic crystals are resonant structures with great potential to be implemented in applications as liquid sensors. The use of the symmetry reduction technique allows introducing relevant transmission features inside bandgaps by creating defect modes in a periodic regular structure. These features can be used as measures to quantify changes in the speed of sound of liquid samples that could be related to the concentration of analytes or the presence of pathogens among other interesting applications. In order to be able to implement this new technology in more challenging applications, such as biomedical applications, it is necessary to have a very precise and accurate measurement. Changes in temperature greatly affect the speed of sound of the liquid samples, causing errors in the measurements. This article presents a phononic crystal sensor that, by introducing additional defect modes, can carry out differential measurements as a temperature compensation mechanism. Theoretical studies using the transmission line model and analytes at various temperatures show that the proposed temperature compensation mechanism enhances the performance of the sensor in a significant way. This temperature compensation strategy could also be implemented in crystals with different topologies.

16.
Am J Physiol Heart Circ Physiol ; 312(6): H1185-H1194, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-28364019

RESUMO

Experimental investigations have established that the stiffness of large arteries has a dependency on acute heart rate (HR) changes. However, the possible underlying mechanisms inherent in this HR dependency have not been well established. This study aimed to explore a plausible viscoelastic mechanism by which HR exerts an influence on arterial stiffness. A multisegment transmission line model of the human arterial tree incorporating fractional viscoelastic components in each segment was used to investigate the effect of varying fractional order parameter (α) of viscoelasticity on the dependence of aortic arch to femoral artery pulse wave velocity (afPWV) on HR. HR was varied from 60 to 100 beats/min at a fixed mean flow of 100 ml/s. PWV was calculated by intersecting tangent method (afPWVTan) and by phase velocity from the transfer function (afPWVTF) in the time and frequency domain, respectively. PWV was significantly and positively associated with HR for α ≥ 0.6; for α = 0.6, 0.8, and 1, HR-dependent changes in afPWVTan were 0.01 ± 0.02, 0.07 ± 0.04, and 0.22 ± 0.09 m/s per 5 beats/min; HR-dependent changes in afPWVTF were 0.02 ± 0.01, 0.12 ± 0.00, and 0.34 ± 0.01 m/s per 5 beats/min, respectively. This crosses the range of previous physiological studies where the dependence of PWV on HR was found to be between 0.08 and 0.10 m/s per 5 beats/min. Therefore, viscoelasticity of the arterial wall could contribute to mechanisms through which large artery stiffness changes with changing HR. Physiological studies are required to confirm this mechanism.NEW & NOTEWORTHY This study used a transmission line model to elucidate the role of arterial viscoelasticity in the dependency of pulse wave velocity on heart rate. The model uses fractional viscoelasticity concepts, which provided novel insights into arterial hemodynamics. This study also provides a means of assessing the clinical manifestation of the association of pulse wave velocity and heart rate.


Assuntos
Aorta Torácica/fisiologia , Artéria Femoral/fisiologia , Frequência Cardíaca , Modelos Cardiovasculares , Análise de Onda de Pulso , Rigidez Vascular , Adaptação Fisiológica , Aorta Torácica/anatomia & histologia , Velocidade do Fluxo Sanguíneo , Elasticidade , Artéria Femoral/anatomia & histologia , Humanos , Fluxo Sanguíneo Regional , Fatores de Tempo , Viscosidade
17.
Comput Methods Programs Biomed ; 129: 71-81, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27084322

RESUMO

BACKGROUND AND OBJECTIVE: Transfer function (TF) is an important parameter for the analysis and understanding of hemodynamics when arterial stenosis exists in human arterial tree. Aimed to validate the feasibility of using TF to diagnose arterial stenosis, the forward problem and inverse problem were simulated and discussed. METHODS: A calculation method of TF between ascending aorta and any other artery was proposed based on a 55 segment transmission line model (TLM) of human artery tree. The effects of artery stenosis on TF were studied in two aspects: stenosis degree and position. The degree of arterial stenosis was specified to be 10-90% in three representative arteries: carotid, aorta and iliac artery, respectively. In order to validate the feasibility of diagnosis of artery stenosis using TF and support vector machine (SVM), a database of TF was established to simulate the real conditions of artery stenosis based on the TLM model. And a diagnosis model of artery stenosis was built by using SVM and the database. RESULTS: The simulating results showed the modulus and phase of TF were decreasing sharply from frequency 2 to 10Hz with the stenosis degree increasing and displayed their unique and nonlinear characteristics when frequency is higher than 10Hz. The diagnosis results showed the average accuracy was above 76% for the stenosis from 10% to 90% degree, and the diagnosis accuracies of moderate (50%) and serious (90%) stenosis were 87% and 99%, respectively. When the stenosis degree increased to 90%, the accuracy of stenosis localization reached up to 94% for most of arteries. CONCLUSIONS: The proposed method of combining TF and SVM is a theoretically feasible method for diagnosis of artery stenosis.


Assuntos
Artérias/patologia , Constrição Patológica/diagnóstico , Modelos Estatísticos , Máquina de Vetores de Suporte , Doenças Vasculares/diagnóstico , Humanos
18.
Ultrasonics ; 54(7): 1929-37, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24861424

RESUMO

The advancement and miniaturization of body implanted medical devices pose several challenges to Ultrasonic Transcutaneous Energy Transfer (UTET), such as the need to reduce the size of the piezoelectric resonator, and the need to maximize the UTET link power-transfer efficiency. Accordingly, the same piezoelectric resonator that is used for energy harvesting at the body implant, may also be used for ultrasonic backward data transfer, for instance, through impedance modulation. This paper presents physical considerations and design guidelines of the body implanted transducer of a UTET link with impedance modulation for a backward data transfer. The acoustic matching design procedure was based on the 2×2 transfer matrix chain analysis, in addition to the Krimholtz Leedom and Matthaei KLM transmission line model. The UTET power transfer was carried out at a frequency of 765 kHz, continuous wave (CW) mode. The backward data transfer was attained by inserting a 9% load resistance variation around its matched value (550 Ohm), resulting in a 12% increase in the acoustic reflection coefficient. A backward data transmission rate of 1200 bits/s was experimentally demonstrated using amplitude shift keying, simultaneously with an acoustic power transfer of 20 mW to the implant.


Assuntos
Transferência de Energia/fisiologia , Próteses e Implantes , Ultrassom/instrumentação , Testes de Impedância Acústica , Acústica , Fontes de Energia Elétrica , Desenho de Equipamento , Humanos , Miniaturização , Modelos Teóricos , Fenômenos Fisiológicos da Pele , Transdutores
19.
Journal of Medical Biomechanics ; (6): E527-E533, 2012.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-803904

RESUMO

Objective To numerically simulate the propagation of pulse wave in human arterial tree by proposing a novel calculation method which combines a transmission line model and a recursive algorithm of input impedance, and to study the effects of individual differences and arterial tree parameters on pulse wave so as to provide references for the analysis on physiologic and pathologic characteristics of human arterial tree. MethodsThe transmission line model of human arterial tree was constructed, which consisted of 55-segment large and medium sized arteries. The recursive algorithm was applied to compute the input impedance of arterial tree at each point. The blood pressures and flows of 55 arteries were calculated and showed in the distribution graphs. Based on this method, the effects of height, heart rate, stroke volume, internal radius and wall thickness on pulse wave propagation and blood pressure distribution were compared. Results The simulation results were in good agreement with the general rules of pulse wave propagation. The propagation of pulse wave in arterial tree showed significantly different characteristics for different parameters. Conclusions The proposed method can effectively simulate the propagation of pulse wave in arterial tree and accurately reflect the effects of individual differences and hemodynamics parameters on pulse wave propagation, and it is an important assistant means for the pathophysiologic analysis and diagnosis of human arterial tree.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...