Arq. bras. cardiol ; 89(3): 176-183, set. 2007. ilus, graf, tab
Artigo em Português | LILACS | ID: lil-462009

RESUMO

OBJETIVO: Determinar a confiabilidade das medidas dos diâmetros basal (DBAB) e pós-oclusão (DPOAB) da artéria braquial e da dilatação fluxo-mediada da artéria braquial (DILA), assim como quantificar o erro típico dessas medidas (ETM). MÉTODOS: A consistência interna (2 medidas intradias) foi determinada em 10 voluntários, enquanto a estabilidade (2 medidas interdias) foi determinada em 13 voluntários aparentemente saudáveis e não-fumantes. As imagens da artéria braquial foram obtidas pelo aparelho de ultra-sonografia bidimensional com Doppler, utilizando transdutor de 14 MHz. As distâncias entre as interfaces íntima-luz foram medidas antes e após interrupção do fluxo sangüíneo durante 5 minutos por manguito posicionado no braço. O DILA foi considerado o porcentual de aumento do DPOAB em relação ao DBAB. RESULTADOS: A ANOVA não identificou diferenças significativas entre as medidas intradias e interdias. Para o DILA, os coeficientes de correlação intraclasse entre as medidas intradias e interdias foram R = 0,7001 e R = 0,8420, respectivamente (p < 0,05). Os coeficientes de variação foram 5,8 por cento e 12,4 por cento e os ETM relativos 13,8 por cento e 14,9 por cento, respectivamente para medidas intra e interdias. A análise dos gráficos de Bland-Altman apontou que as variáveis não apresentaram erro heterocedástico. CONCLUSÃO: A medida do DBAB, DPOAB e do DILA por meio de técnica manual pela ultra-sonografia apresenta alta confiabilidade tanto para os valores intradias quanto interdias, possibilitando seu uso para diagnóstico e monitoramento da função endotelial.


OBJECTIVE: To determine the reliability of the baseline (BBAB) and post occlusion (POBAD) brachial artery diameters, brachial artery flow-mediated dilatations (BAFMD) measurements, and to quantify the typical error of the measurements (TEM). METHODS: Internal consistency (2 measurements on the same day) was determined in 10 volunteers, whereas stability (2 measurements on separate days) was determined in 13 volunteers. All the volunteers looked healthy and were nonsmokers. The brachial artery images were obtained using a two dimensional Doppler ultrasound instrument: a 14 MHz transducer was used. The distances between the intima-lumen interfaces were measured before and after the blood flow had been stopped by means of a cuff on the arm for five minutes. BAFMD was considered as the percentile increase of POBAD in relation to BBAD. RESULTS: ANOVA did not identify any significant differences between the measurements taken on the same and separate days. For BAFMD, the intraclass correlation coefficients between the measurements taken on the same and separate days were: R = 0.7001 and R = 0.8420, respectively (p < 0.05). The variation coefficients were 5.8 percent and 12.4 percent and the relative SMEs were 13.8 percent and 14.9 percent, respectively, for the measurements taken on the same and separate days. Analysis of the Bland-Altman graphs indicated that the variables did not present heteroscedastic errors. CONCLUSION: The BBAD, POBAD and BAFMD measurements using the manual ultrasound technique were highly reliable for both the same and separate day measurements and therefore can be used to diagnose and monitor endothelial function.


Assuntos
Adulto , Feminino , Humanos , Masculino , Braço/irrigação sanguínea , Artéria Braquial/fisiologia , Vasodilatação/fisiologia , Análise de Variância , Artéria Braquial/anatomia & histologia , Artéria Braquial , Interpretação Estatística de Dados , Endotélio Vascular/fisiologia , Endotélio Vascular , Fluxo Sanguíneo Regional/fisiologia , Fatores de Tempo , Ultrassonografia Doppler
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...