Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
1.
Sensors (Basel) ; 24(11)2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38894103

RESUMO

In answer to the demand for high sensitivity and miniaturization of ultra-high frequency (UHF) sensors for partial discharge (PD) detection in power equipment, this paper proposes research on miniaturized UHF-sensing technology for PD detection in power equipment based on symmetric cut theory. The symmetric cut theory is applied for the first time to the miniaturization of PD UHF sensors for power equipment. A planar monopole UHF sensor with a size of only 70 mm × 70 mm × 1.6 mm is developed using an exponential asymptotic feed line approach, which is a 50% size reduction. The frequency-response characteristics of the sensor are simulated, optimized and tested; the results show that the standing wave ratio of the sensor developed in this paper is less than 2 in the frequency band from 427 MHz to 1.54 GHz, and less than 5 in the frequency band from 300 MHz to 1.95 GHz; in the 300 MHz~1.5 GHz band; the maximum and average gains of the sensor E-plane are 4.76 dB and 1.02 dB, respectively. Finally, the PD simulation experiment platform for power equipment is built to test the sensor's sensing performance; the results show that the sensor can effectively detect the PD signals; the sensing sensitivity is improved by about 95% relative to an elliptical monopole UHF sensor.

2.
Muscle Nerve ; 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38708872

RESUMO

INTRODUCTION/AIMS: Ultra high-frequency ultrasound (UHFUS) has been demonstrated to allow easy visualization and quantification of median and digital nerve fascicles; however, there is a lack of normative data for other upper limb nerves. The purpose of this study was to use UHFUS to establish normative reference values and ranges for fascicle count and density within selected upper extremity nerves. METHODS: Twenty-one healthy volunteers underwent sonographic examination of the ulnar, superficial branch of the radial, and radial nerves on one upper limb using UHFUS with a 48 MHz linear transducer. The number of fascicles in each peripheral nerve and fascicle density were assessed. RESULTS: The mean fascicle number and fascicle density for each of the measured nerves was ulnar nerve at the wrist 11.7 and 2.0, ulnar nerve at the elbow 9.2 and 1.1, superficial branch of the radial nerve 7.3 and 2.5, and radial nerve at the spiral groove 4.2 and 0.8. A single significant association was observed between CSA and fascicle number in the ulnar nerve at the wrist (p = .023, r = 0.66). Neither fascicle number nor density could be predicted by age, sex, height, weight, or body mass index. DISCUSSION: UHFUS may help to establish a baseline of normative data on upper limb nerves that are not frequently biopsied due to their mixed motor and sensory functions and has the potential for increased understanding of nerve fascicular anatomy to improve diagnostic accuracy of focal nerve lesions, particularly those with selective fascicular involvement.

3.
J Cardiovasc Dev Dis ; 11(3)2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38535099

RESUMO

Identifying electrical dyssynchrony is crucial for cardiac pacing and cardiac resynchronization therapy (CRT). The ultra-high-frequency electrocardiography (UHF-ECG) technique allows instantaneous dyssynchrony analyses with real-time visualization. This review explores the physiological background of higher frequencies in ventricular conduction and the translational evolution of UHF-ECG in cardiac pacing and CRT. Although high-frequency components were studied half a century ago, their exploration in the dyssynchrony context is rare. UHF-ECG records ECG signals from eight precordial leads over multiple beats in time. After initial conceptual studies, the implementation of an instant visualization of ventricular activation led to clinical implementation with minimal patient burden. UHF-ECG aids patient selection in biventricular CRT and evaluates ventricular activation during various forms of conduction system pacing (CSP). UHF-ECG ventricular electrical dyssynchrony has been associated with clinical outcomes in a large retrospective CRT cohort and has been used to study the electrophysiological differences between CSP methods, including His bundle pacing, left bundle branch (area) pacing, left ventricular septal pacing and conventional biventricular pacing. UHF-ECG can potentially be used to determine a tailored resynchronization approach (CRT through biventricular pacing or CSP) based on the electrical substrate (true LBBB vs. non-specified intraventricular conduction delay with more distal left ventricular conduction disease), for the optimization of CRT and holds promise beyond CRT for the risk stratification of ventricular arrhythmias.

4.
J Ultrasound Med ; 43(1): 71-76, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37750808

RESUMO

OBJECTIVE: This study aimed to identify the sonographic features of pathologically confirmed onychopapilloma cases. METHODS: High-frequency up to 24 MHz and ultra-high frequency-ultrasound up to 71 MHz examinations were performed and correlated with their clinical and pathologic presentations. RESULTS: Twenty-two cases met the criteria. Clinical presentations revealed longitudinal erythronychia in 63.3% of cases. The ultrasound examinations identified a hypoechoic band in the nail bed (86.3%), nail plate abnormalities including upward displacement (68.2%) and thickening (68.1%), focal hyperechoic focal spots on the nail plate (50%) and irregularities of the ventral plate (33.3%). Color Doppler imaging showed no hypervascularity of the nail bed in all studies. These findings correlate with histological characteristics of onychopapilloma, including nail bed acanthosis, papillomatosis, and layered hyperkeratosis. Recurrence occurred in two cases after surgery, with tumors showing proximal extension in the matrix region on ultrasound not evident during clinical examination. CONCLUSION: High-frequency and ultra-high-frequency can provide anatomical information in onychopapilloma that could enhance understanding and management.


Assuntos
Doenças da Unha , Papiloma , Humanos , Doenças da Unha/diagnóstico por imagem , Papiloma/patologia , Unhas/diagnóstico por imagem , Ultrassonografia , Ultrassonografia Doppler em Cores
5.
Sensors (Basel) ; 23(22)2023 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-38005541

RESUMO

Low-frequency aperture arrays represent sensitive instruments to detect signals from radio astronomic sources situated in the universe. In Italy, the Sardinia Aperture Array Demonstrator (SAAD) consists of an ongoing project of the Italian National Institute for Astrophysics (INAF) aimed to install an aperture array constituted of 128 dual-polarized Vivaldi antennas at the Sardinia Radio Telescope (SRT) site. The originally envisaged 128 elements of SAAD were re-scoped to the 16 elements of its precursor named SADino, with the aim to quickly test the system with a digital beam-former based on the Italian Tile Processing Module (iTPM) digital back-end. A preliminary measurements campaign of radio frequency interference (RFI) was performed to survey the less contaminated spectral region. The results of these measurements permitted the establishment of the technical requirements for receiving a chain for the SADino telescope. In this paper, the design, implementation, and characterization of this signal acquisition chain are proposed. The operative frequency window of SAAD and its precursor, SADino, sweeps from 260 MHz to 420 MHz, which appears very attractive for radio astronomy applications and radar observation in space and surveillance awareness (SSA) activities.

6.
Front Cardiovasc Med ; 10: 1264921, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37859683

RESUMO

Background and aim: Pre-eclampsia (PE) is related to elevated blood pressure (BP) in children. The study aims to investigate if elevated BP is reflected in child arterial health and how anthropometrics, body composition, and gestational and perinatal factors influenced this. Methods: In this prospective cohort study, we assessed the arteries of 182 children exposed (46 had an early onset, with a diagnosis before 34 gestational weeks, and 136 had a late onset) and 85 children unexposed (non-PE) to PE at 8-12 years from delivery using ultra-high-frequency ultrasound in addition to ambulatory and central BPs, body composition and anthropometrics, and tonometry-derived pulse wave velocity (PWV). Results: No differences were found in intima-media thickness (IMT), adventitia thickness (AT), lumen diameter (LD), local carotid artery stiffness, distensibility, or wall stress between PE-exposed and non-PE-exposed children. All children's brachial, radial, and femoral artery IMTs were associated with 24-h systolic BP (SBP) and pulse pressure, carotid-femoral PWV, and anthropometric measures. The 24-h SBP and anthropometrics, notably lean body mass, were independent predictors of peripheral artery IMTs (brachial R2 = 0.217, radial R2 = 0.208, femoral R2 = 0.214; p < 0.001). Head circumference predicted carotid artery IMT and LD (ß = 0.163, p = 0.009; ß = 0.417, p < 0.001, respectively), but carotid artery IMT was not associated with BP. No independent associations were found for peripheral artery ATs. Local carotid artery stiffness, distensibility, and wall stress were independently associated with adiposity. No significant associations were found between gestational or perinatal factors and child vascular health parameters. Conclusions: The peripheral artery IMT of PE-exposed children is identical to that of non-PE-exposed children, but associated with BP. Adiposity is related to local carotid artery stiffness. These adverse associations in arterial health may reflect the early progression of cardiovascular disease in PE-exposed children.

7.
Diagnostics (Basel) ; 13(17)2023 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-37685259

RESUMO

Atopic dermatitis (AD) is a chronic multifactorial inflammatory disease characterized by intense itching and inflammatory eczematous lesions. Biological disease-modifying drugs, such as dupilumab are recommended for patients with moderate-to-severe AD, refractory to systemic immunosuppressive therapies. Disease monitoring is performed by clinical scores. Since 1970, however, the use of ultrasound and particularly high-frequency ultrasound (HFUS), has identified alterations in dermal echogenicity, called the subepidermal low-echogenic band (SLEB), that correlates with disease severity and response to treatment. We enrolled 18 patients with moderate-to-severe AD, divided into two groups: twelve patients in the dupilumab treatment (Group A) and six patients in standard treatment, from February 2019 to November 2019. We performed ultra-high frequency ultrasound (UHFUS) evaluation of lesional and non-lesional skin, focusing on SLEB average thicknesses measurement, epidermal thickness, and vascular signal in correlation with objective disease scores (EASI, IGA), patient's reported scores (Sleep Quality NRS and Itch NRS), and TEWL and corneometry at baseline (T0), after 1 month (T1) and 2 months (T2). The SLEB average thickness measurement, vascular signal, and epidermal thickness showed a statistically significant reduction in lesional skin of the biological treatment group and no significant reduction in non-lesional skin in both groups. In the lesional skin of the standard treatment group, only epidermal thickness showed a statistically significant reduction. Our study demonstrates that SLEB measurement, vascular signals, and epidermal thickness could be used as objective parameters in monitoring the AD treatment response, while the presence of SLEB in non-lesional skin could be used as a marker of subclinical inflammation and could predict development of clinical lesions, suggesting a pro-active therapy. Further follow-up and research are needed to clarify the association of SLEB decrease/disappearance with a reduction of flares/prolongment of the disease remission time.

8.
Diagnostics (Basel) ; 13(17)2023 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-37685297

RESUMO

Ultra-high-frequency ultrasound (UHFUS) has a reported potential to differentiate between aganglionic and ganglionic bowel wall, referred to as histoanatomical differences. A good correlation between histoanatomy and UHFUS of the bowel wall has been proven. In order to perform more precise and objective histoanatomical morphometrics, the main research objective of this study was to develop a computer program for the assessment and automatic calculation of the histoanatomical morphometrics of the bowel wall in UHFUS images. A computer program for UHFUS diagnostics was developed and presented. A user interface was developed in close collaboration between pediatric surgeons and biomedical engineers, to enable interaction with UHFUS images. Images from ex vivo bowel wall samples of 23 children with recto-sigmoid Hirschsprung's disease were inserted. The program calculated both thickness and amplitudes (image whiteness) within different histoanatomical bowel wall layers. Two observers assessed the images using the program and the inter-observer variability was evaluated. There was an excellent agreement between observers, with an intraclass correlation coefficient range of 0.970-0.998. Bland-Altman plots showed flat and narrow distributions. The mean differences ranged from 0.005 to 0.016 mm in thickness and 0 to 0.7 in amplitude units, corresponding to 1.1-3.6% and 0.0-0.8% from the overall mean. The computer program enables and ensures objective, accurate and time-efficient measurements of histoanatomical thicknesses and amplitudes in UHFUS images of the bowel wall. The program can potentially be used for several bowel wall conditions, accelerating research within UHFUS diagnostics.

9.
Diagnostics (Basel) ; 13(17)2023 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-37685298

RESUMO

Dermal hyaluronic acid (HA) fillers are used for nasolabial fold correction, but no study is still available on the use of ultra-high-frequency ultrasound (UHFUS) with 70 MHz probes for the evaluation of HA distribution and wrinkle amelioration. We selected 13 patients who received HA filler, evaluated before (Time (T) 0) and after injection (T1), and after 24 weeks (T2). The dermal thickness and distribution of HA were registered, as well as the Wrinkle Severity Rating Scale (WSRS), Global Aesthetic Improvement Scale (GAIS), and wrinkle 3D fullness. The UHFUS dermal thickness was increased by 11% for both sides at T1 and by 7.4% and 6.8% for the right and left side, respectively, at T2 (p < 0.01). The 3D wrinkle fullness showed a T1 increase (+0.59 cc and +0.79 cc for the right and left side, respectively) with a T2 maintenance of 45% of the T1 fullness (p-value < 0.001). The only clinical score significantly modified was WSRS, with a reduction of 56% at T1 and of 47.1% at T2 (p-value < 0.001). Our study then demonstrated the efficacy of UHFUS in the assessment of nasolabial fold correction, representing also the first multi-modal evaluation of HA persistence and its visual subsequent aesthetic results.

10.
Diagnostics (Basel) ; 13(17)2023 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-37685309

RESUMO

Sjögren's Disease (SjD) is a chronic autoimmune disorder that affects the salivary and lacrimal glands, leading to xerostomia and xerophthalmia. Ultrasonography of Major Salivary Glands (SGUS) is a well-established tool for the identification of the salivary glands' abnormalities in SjD. Recently, a growing interest has arisen in the assessment of the other exocrine glands with ultrasonography: lacrimal glands (LGUS) and labial salivary glands (LSGUS). The objective of this study is to explore the practical applications of ultra-high frequency ultrasound (UHFUS) in the assessment of lacrimal glands and labial salivary glands. Indeed, UHFUS, with its improved spatial resolution compared to conventional ultrasonography, allows for the evaluation of microscopic structures and has been successfully applied in various medical fields. In lacrimal glands, conventional high-frequency ultrasound (HFUS) can detect characteristic inflammatory changes, atrophic alterations, blood flow patterns, and neoplastic lesions associated with SjD. However, sometimes it is challenging to identify lacrimal glands characteristics, thus making UHFUS a promising tool. Regarding labial salivary glands, limited research is available with conventional HFUS, but UHFUS proves to be a good tool to evaluate glandular inhomogeneity and to guide labial salivary glands biopsy. The comprehensive understanding of organ involvement facilitated by UHFUS may significantly improve the management of SjD patients.

11.
Diagnostics (Basel) ; 13(17)2023 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-37685344

RESUMO

Pyoderma gangrenosum (PG) is a neutrophilic dermatological disease, whose pathogenesis is still poorly clarified. Because of the lack of validated criteria for diagnosis and response, PG treatment is still challenging and should be differentiated in the inflammatory and non-inflammatory phases. Our study aimed to provide a new semi-quantitative approach for PG diagnosis and monitoring, identifying ultra-high-frequency ultrasound (UHFUS) early biomarkers associated with the transition between the two phases. We enrolled 13 patients affected by painful PG lesions evaluated during the inflammatory phase (T0) and during the non-inflammatory phase (T1): pain was measured by the Visual Analogue Scale (VAS); clinical features were recorded through digital photography; epidermis and dermis ultrasound (US) characteristics were evaluated by UHFUS examination with a 70 MHz probe (Vevo MD® FUJIFILM VisualSonics). In T1 UHFUS examination, the presence of hyperechoic oval structures was lower compared to T0 (p value < 0.05). An hyperechogenic structure within the oval structure, suggestive of a hair tract, was evident in T0 and absent in T1 (p value < 0.05). In T0, blood vessels appear as U-shaped and V-shaped anechoic structures with a predominance of U-shaped vessels (p value < 0.05) compared to the more regular distribution found in T1. Finding early biomarkers of the transition from the inflammatory to the non-inflammatory phase could provide new insight in terms of therapeutic decision making and response monitoring. The differences found by this study suggest a potential use of UHFUS for the development of an objective standardized staging method. Further investigations will be necessary to confirm our preliminary results, thus providing a turning point in PG early detection, differential diagnosis and treatment monitoring.

12.
Sensors (Basel) ; 23(15)2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37571631

RESUMO

To meet the real demand for broadband full-band high-gain antenna sensors in the process of partial discharge (PD) Ultra-High frequency (UHF) detection test and online monitoring of power equipment, this paper builds a resonant cavity monopole UHF antenna sensor based on Fabry-Perot resonant cavity antenna technology, conducts the sensor Voltage Standing Wave Ratio (VSWR) optimization study using curved flow technology, conducts the sensor gain optimization study using slot dual resonant structure, and, finally, tests the sensor performance using the built PD detection test platform. The resonant cavity monopole antenna exhibits outstanding VSWR performance in the frequency range of 0.37 GHz-3 GHz, according to simulation and test data: the average gain in the frequency range of 0.3 GHz-3 GHz is 4.92 dBi, and the highest gain at the primary resonant frequency of 1.0 GHz is 7.16 dBi, with good radiation performance over the whole frequency spectrum. The electromagnetic pulse signal sensed by the UHF sensor developed in this paper can demonstrate the energy spectrum distribution characteristics of PD radiation electromagnetic wave signal more comprehensively, laying a firm technical foundation for thoroughly understanding the electromagnetic wave radiation characteristics of various types of PD insulation defects of various power equipment and the selection of a specific direction for its supporting optimization.

13.
Diagnostics (Basel) ; 13(16)2023 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-37627974

RESUMO

Psoriatic onychopathy is one of the clinical presentations of psoriasis and a well-known risk factor for the development of psoriatic arthritis. High-frequency ultrasounds (HFUS > 20 MHz) have recently been used to evaluate the nail apparatus of healthy and psoriatic subjects. The aim of our study was to detect by means of ultra-high-frequency ultrasound (UHFUS 70-100 MHz) alterations of the nail bed and matrix in patients with psoriatic onychopathy and to monitor these parameters during the treatment with monoclonal antibody (mAb). We enrolled 10 patients with psoriatic onychopathy and naive to previous biologic therapies. Patients were evaluated at baseline, after 1 month and after 3 months from the beginning of mAb therapy by a complete clinical assessment and US evaluation. A UHFUS examination with a 70 MHz probe was performed on the thumbnail (I), the index fingernail (II) and the nail with greater clinical impairment (W). The following measurements were analyzed: nail plate thickness (A), nail bed thickness (B), nail insertion length (C), nail matrix length (D) and nail matrix thickness (E). Among the various parameters analyzed, some measures showed a statistically significant decrease with p-value < 0.05 (t0 WA = 0.52 mm vs. t2 WA = 0.42 mm; t0 WB = 2.8 mm vs. t2 WB = 2.4 mm; t0 WE = 0.76 mm vs. t2 WE = 0.64 mm; t0 IIA = 0.49 mm vs. t2 IIA = 0.39 mm). In conclusion, UHFUS could represent a viable imaging technique for the real-time evaluation and monitoring of psoriatic onychopathy, thus supporting the clinical parameters and revealing any subclinical signs of early drug response.

14.
Eur Heart J Suppl ; 25(Suppl C): C234-C241, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37125312

RESUMO

The conduction system of the human heart is composed of specialized cardiomyocytes that initiate and propagate the electric impulse with consequent rhythmic and synchronized contraction of the atria and ventricles, resulting in the normal cardiac cycle. Although the His-Purkinje system (HPS) was already described more than a century ago, there has been a recent resurgence of conduction system pacing (CSP), where pacing leads are positioned in the His bundle region and left bundle branch area to provide physiological cardiac activation as alternatives to the unnatural myocardial stimulation obtained with conventional right ventricular and biventricular pacing. In this review, we describe the fundamental anatomical and pathophysiological aspects of the specialized HPS along with the CSP technique's nuts and bolts to highlight its potential benefits in everyday clinical practice.

15.
Diagnostics (Basel) ; 13(8)2023 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-37189490

RESUMO

Hirschsprung's disease (HD) is characterized by aganglionosis in the bowel wall, requiring resection. Ultra-high frequency ultrasound (UHFUS) imaging of the bowel wall has been suggested to be an instantaneous method of deciding resection length. The aim of this study was to validate UHFUS imaging of the bowel wall in children with HD by exploring the correlation and systematic differences between UHFUS and histopathology. Resected fresh bowel specimens of children 0-1 years old, operated on for rectosigmoid aganglionosis at a national HD center 2018-2021, were examined ex vivo with UHFUS center frequency 50 MHz. Aganglionosis and ganglionosis were confirmed by histopathological staining and immunohistochemistry. Histoanatomical layers of bowel wall in histopathological and UHFUS images, respectively, were outlined using MATLAB programs. Both histopathological and UHFUS images were available for 19 aganglionic and 18 ganglionic specimens. The thickness of muscularis interna correlated positively between histopathology and UHFUS in both aganglionosis (R = 0.651, p = 0.003) and ganglionosis (R = 0.534, p = 0.023). The muscularis interna was systematically thicker in histopathology than in UHFUS images in both aganglionosis (0.499 vs. 0.309 mm; p < 0.001) and ganglionosis (0.644 versus 0.556 mm; p = 0.003). Significant correlations and systematic differences between histopathological and UHFUS images support the hypothesis that UHFUS reproduces the histoanatomy of the bowel wall in HD accurately.

16.
Diagnostics (Basel) ; 13(8)2023 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-37189596

RESUMO

Background: To assess skin involvement in a cohort of patients with systemic sclerosis (SSc) by comparing results obtained from modified Rodnan skin score (mRSS), durometry and ultra-high frequency ultrasound (UHFUS). Methods: SSc patients were enrolled along with healthy controls (HC), assessing disease-specific characteristics. Five regions of interest were investigated in the non-dominant upper limb. Each patient underwent a rheumatological evaluation of the mRSS, dermatological measurement with a durometer, and radiological UHFUS assessment with a 70 MHz probe calculating the mean grayscale value (MGV). Results: Forty-seven SSc patients (87.2% female, mean age 56.4 years) and 15 HC comparable for age and sex were enrolled. Durometry showed a positive correlation with mRSS in most regions of interest (p = 0.025, ρ = 0.34 in mean). When performing UHFUS, SSc patients had a significantly thicker epidermal layer (p < 0.001) and lower epidermal MGV (p = 0.01) than HC in almost all the different regions of interest. Lower values of dermal MGV were found at the distal and intermediate phalanx (p < 0.01). No relationships were found between UHFUS results either with mRSS or durometry. Conclusions: UHFUS is an emergent tool for skin assessment in SSc, showing significant alterations concerning skin thickness and echogenicity when compared with HC. The lack of correlations between UHFUS and both mRSS and durometry suggests that these are not equivalent techniques but may represent complementary methods for a full non-invasive skin evaluation in SSc.

17.
Entropy (Basel) ; 25(4)2023 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-37190361

RESUMO

The location of the partial discharge source is an important part of fault diagnosis inside power equipment. As a key step of the ultra-high frequency location method, the extraction of the time difference of arrival can generate large errors due to interference. To achieve accurate time difference extraction and further multi-source partial discharge location, a location method with comprehensive time difference extraction and a multi-data dynamic weighting algorithm is proposed. For time difference extraction, the optimized energy accumulation curve method applies wavelet transform and mode maximization calculations such that it overcomes the effect of interference signals before the wave peak. The secondary correlation method improves the interference capability by performing two rounds of correlation calculations. Both extraction methods are combined to reduce the error in time difference extraction. Then, the dynamic weighting algorithm effectively utilizes multiple data and improves the location accuracy. Experimental results on multi-source partial discharge locations performed in a transformer tank validate the accuracy of the proposed method.

18.
Diagnostics (Basel) ; 13(10)2023 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-37238152

RESUMO

It has been shown that ultra-high frequency (UHF) ultrasound applied to the external bowel wall can delineate the histo-anatomic layers in detail and distinguish normal bowel from aganglionosis. This would potentially reduce or lessen the need for biopsies that are currently mandatory for the diagnosis of Hirschsprung's disease. However, to our knowledge, no suitable rectal probes for such a use are on the market. The aim was to define the specifications of an UHF transrectal ultrasound probe (50 MHz center frequency) suitable for use in infants. Probe requirements according to patient anatomy, clinicians' requests, and biomedical engineering UHF prerequisites were collected within an expert group. Suitable probes on the market and in clinical use were reviewed. The requirements were transferred into the sketching of potential UHF ultrasound transrectal probes followed by their 3D prototype printing. Two prototypes were created and tested by five pediatric surgeons. The larger and straight 8 mm head and shaft probe was preferred as it facilitated stability, ease of anal insertion, and possible UHF technique including 128 piezoelectric elements in a linear array. We hereby present the procedure and considerations behind the development of a proposed new UHF transrectal pediatric probe. Such a device can open new possibilities for the diagnostics of pediatric anorectal conditions.

19.
Front Cardiovasc Med ; 10: 1140988, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37034324

RESUMO

Background: Left bundle branch pacing (LBBP) produces delayed, unphysiological activation of the right ventricle. Using ultra-high-frequency electrocardiography (UHF-ECG), we explored how bipolar anodal septal pacing with direct LBB capture (aLBBP) affects the resultant ventricular depolarization pattern. Methods: In patients with bradycardia, His bundle pacing (HBP), unipolar nonselective LBBP (nsLBBP), aLBBP, and right ventricular septal pacing (RVSP) were performed. Timing of local ventricular activation, in leads V1-V8, was displayed using UHF-ECG, and electrical dyssynchrony (e-DYS) was calculated as the difference between the first and last activation. Durations of local depolarizations were determined as the width of the UHF-QRS complex at 50% of its amplitude. Results: aLBBP was feasible in 63 of 75 consecutive patients with successful nsLBBP. aLBBP significantly improved ventricular dyssynchrony (mean -9 ms; 95% CI (-12;-6) vs. -24 ms (-27;-21), ), p < 0.001) and shortened local depolarization durations in V1-V4 (mean differences -7 ms to -5 ms (-11;-1), p < 0.05) compared to nsLBBP. aLBBP resulted in e-DYS -9 ms (-12; -6) vs. e-DYS 10 ms (7;14), p < 0.001 during HBP. Local depolarization durations in V1-V2 during aLBBP were longer than HBP (differences 5-9 ms (1;14), p < 0.05, with local depolarization duration in V1 during aLBBP being the same as during RVSP (difference 2 ms (-2;6), p = 0.52). Conclusion: Although aLBBP improved ventricular synchrony and depolarization duration of the septum and RV compared to unipolar nsLBBP, the resultant ventricular depolarization was still less physiological than during HBP.

20.
Plants (Basel) ; 12(7)2023 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-37050103

RESUMO

Microwaves have been applied to the drying of seeds of several species due to their maintenance of the quality of the seeds and reduction of time and costs. However, few is known about the effect of microwaves on the increase of the physiological quality of soybean seeds and especially their effects on longevity. Therefore, the use of microwaves as magneto-priming in soybean seeds was the object of study in this work. For this purpose, two soybean cultivars were selected and submitted to the ultra-high frequency (UHF) microwave exposure of 2.45 GHz, in the wavelength of 11 cm, and power of 0.2 W/g, for 15 min. The results showed that this condition of exposure to the microwave brought benefits in both cultivars after treatment. Incremental improvements were observed in the germinability indexes, the seedling length, the water absorption by the seeds, the fresh mass, dry mass, and longevity. The genes related to seed germination and longevity showed superior expression (HSFA3, HSP21, HSP17.6b, EXP, ABI3) with magneto-priming treatment. The data found ensure the use of the technique as a viable option for pre-treatment as magneto-priming in soybean seeds in order to improve seed quality.

SELEÇÃO DE REFERÊNCIAS