Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 434
Filtrar
1.
Acta Biomater ; 2024 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-39222704

RESUMO

Skin-electronic interfaces have broad applications in fields such as diagnostics, therapy, health monitoring, and smart wearables. However, they face various challenges in practical use. For instance, in wet environments, the cohesion of the material may be compromised, and under dynamic conditions, maintaining conformal adhesion becomes difficult, leading to reduced sensitivity and fidelity of electrical signal transmission. The key scientific issue lies in forming a stable and tight mechanical-electronic coupling at the tissue-electronic interface. Here, inspired by octopus sucker structures and snail mucus, we propose a strategy for hydrogel skin-electronic interfaces based on multi-coupled bioinspired adhesion and introduce an ultrasound (US)-mediated interfacial toughness enhancement mechanism. Ultimately, using digital light processing micro-nano additive manufacturing technology (DLP 3D), we have developed a multifunctional, diagnostic-therapeutic integrated patch (PAMS). This patch exhibits moderate water swelling properties, a maximum deformation of up to 460 %, high sensitivity (GF=4.73), and tough and controllable bioadhesion (shear strength increased by 109.29 %). Apart from outstanding mechanical and electronic properties, the patch also demonstrates good biocompatibility, anti-bacterial properties, photothermal properties, and resistance to freezing at -20°C. Experimental results show that this skin-electronic interface can sensitively monitor temperature, motion, and electrocardiogram signals. Utilizing a rat frostbite model, we have demonstrated that this skin-electronic interface can effectively accelerate the wound healing process as a wound patch. This research offers a promising strategy for improving the performance of bioelectronic devices and personalized diagnostics and therapeutics in the future. STATEMENT OF SIGNIFICANCE: Establishing stable and tight mechanical-electronic coupling at the tissue-electronic interface is essential for the diverse applications of bioelectronic devices. This study aims to develop a multifunctional, diagnostic-therapeutic integrated hydrogel skin-electronic interface patch with enhanced interfacial toughness. The patch is based on a multi-coupled bioinspired adhesive-enhanced mechanism, allowing for personalized 3D printing customization. It can be used as a high-performance diagnostic-therapeutic sensor and effectively promote frostbite wound healing. We anticipate that this research will provide new insights for constructing the next generation of multifunctional integrated high-performance bioelectronic interfaces.

2.
Cureus ; 16(8): e65951, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39229413

RESUMO

There is a broad differential for new-onset cardiac dysrhythmia, and the rapid identification of the underlying cause of these cardiac emergencies can be lifesaving. Identifying wall motion abnormalities on point-of-care ultrasound (POCUS) is not a core echocardiography application for Emergency Medicine (EM) physicians. However, ruling in a regional wall motion abnormality can expedite patient-centered care and assist the busy EM physician in high-risk cases.

3.
Quant Imaging Med Surg ; 14(8): 5721-5736, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39144013

RESUMO

Background: The contrasted-enhanced ultrasound thyroid imaging reporting and data system (CEUS TI-RADS) is the first international risk stratification system for thyroid nodules based on conventional ultrasound (US) and CEUS. This study aimed to evaluate the diagnostic efficacy of CEUS TI-RADS for benign and malignant thyroid nodules and to assess the related interobserver agreement. Methods: The study recruited 433 patients who underwent thyroid US and CEUS between January 2019 and June 2023 at the Affiliated Hospital of Guangdong Medical University. A retrospective analysis of 467 thyroid nodules confirmed by fine-needle aspiration (FNA) and/or surgery was performed. Further, a CEUS TI-RADS classification was assigned to each thyroid nodule based on the CEUS TI-RADS scoring criteria for the US and CEUS features of the nodule. The nodules were grouped based on their sizes as follows: size ≤1 cm, group A; size >1 and ≤4 cm, group B; and size >4 cm, group C. Multivariate logistic regression was used to analyze independent risk factors for malignant thyroid nodules. Pathological assessment was the reference standard for establishing the sensitivity (SEN), specificity (SPE), accuracy (ACC), positive predictive value (PPV), and negative predictive value (NPV) of CEUS TI-RADS in diagnosing malignant thyroid nodules. The area under the curve (AUC) in the receiver operating characteristic (ROC) curve analysis was used to compare the diagnostic efficacy of the scoring system in predicting malignancy in three groups of nodules. The intragroup correlation coefficient (ICC) was adopted to assess the interobserver agreement of the CEUS TI-RADS score. Results: Out of the 467 thyroid nodules, 262 were malignant and 205 were benign. Logistic regression analysis revealed that the independent risk factors for malignant thyroid nodules included punctate echogenic foci (P<0.001), taller-than-wide shape (P=0.015), extrathyroidal invasion (P=0.020), irregular margins/lobulation (P=0.036), hypoechoicity on US (P=0.038), and hypoenhancement on CEUS (P<0.001). The AUC for the CEUS TI-RADS in diagnosing malignant thyroid nodules was 0.898 for all nodules, 0.795 for group A, 0.949 for group B, and 0.801 for group C, with the optimal cutoff values of the CEUS TI-RADS being 5 points, 6 points, 5 points, and 5 points, respectively. Among these groups of nodules, group B had the highest AUC, with the SEN, SPE, ACC, PPV, and NPV for diagnosing malignant nodules being 95.9%, 88.1%, 92.8%, 92.6%, and 93.2%, respectively. The ICC of the CEUS TI-RADS classification between senior and junior physicians was 0.862 (P<0.001). Conclusions: In summary, CEUS TI-RADS demonstrated significant efficacy in distinguishing thyroid nodules. Nonetheless, there were variations in its capacity to detect malignant nodules across diverse sizes, and it demonstrate optimal performance in 1- to 4-cm nodules. These findings may serve as important insights for clinical diagnoses.

4.
Quant Imaging Med Surg ; 14(8): 5932-5945, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39144053

RESUMO

Background: The incidence rate of thyroid nodules has reached 65%, but only 5-15% of these modules are malignant. Therefore, accurately determining the benign and malignant nature of thyroid nodules can prevent unnecessary treatment. We aimed to develop a deep-learning (DL) radiomics model based on ultrasound (US), explore its diagnostic efficacy for benign and malignant thyroid nodules, and verify whether it improved the diagnostic level of physicians. Methods: We retrospectively included 1,076 thyroid nodules from 817 patients at three institutions. The radiomics and DL features of the US images were extracted and used to construct radiomics signature (Rad_sig) and deep-learning signature (DL_sig). A Pearson correlation analysis and least absolute shrinkage and selection operator (LASSO) regression analysis were used for feature selection. Clinical US semantic signature (C_US_sig) was constructed based on clinical information and US semantic features. Next, a combined model was constructed based on the above three signatures in the form of a nomogram. The model was constructed using a development set (institution 1: 719 nodules), and the model was evaluated using two external validation sets (institution 2: 74 nodules, and institution 3: 283 nodules). The performance of the model was assessed using decision curve analysis (DCA) and calibration curves. Furthermore, the C_US_sigs of junior physicians, senior physicians, and expers were constructed. The DL radiomics model was used to assist the physicians with different levels of experience in the interpretation of thyroid nodules. Results: In the development and validation sets, the combined model showed the highest performance, with areas under the curve (AUCs) of 0.947, 0.917, and 0.929, respectively. The DCA results showed that the comprehensive nomogram had the best clinical utility. The calibration curves indicated good calibration for all models. The AUCs for distinguishing between benign and malignant thyroid nodules by junior physicians, senior physicians, and experts were 0.714-0.752, 0.740-0.824, and 0.891-0.908, respectively; however, with the assistance of DL radiomics, the AUCs reached 0.858-0.923, 0.888-0.944, and 0.912-0.919, respectively. Conclusions: The nomogram based on DL radiomics had high diagnostic efficacy for thyroid nodules, and DL radiomics could assist physicians with different levels of experience to improve their diagnostic level.

5.
Cureus ; 16(7): e64509, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39139307

RESUMO

BACKGROUND: Acute appendicitis (AA) is the most common emergency general surgical condition worldwide. Diagnosis is challenging and incorporates clinical, biochemical and radiological investigations. Our aim was to provide data from routine practice investigating widely utilised diagnostic methods from a single centre within the United Kingdom. METHODS: We conducted a retrospective observational cohort study of patients who underwent a laparoscopic appendicectomy for AA between April 2022 and March 2023. AA was defined as the presence of transmural polymorphonuclear leukocytes in histology. Subgroup analysis was performed on paediatric patients. Factors associated with AA were investigated, and the diagnostic utility of biochemical and radiological investigations was examined. RESULTS: A total of 330 appendicectomies were analysed. We found an overall negative appendicectomy rate (NAR) of 38% and 48% in paediatric patients. Independent factors associated with AA on the multivariate analysis included elevated neutrophil counts (>7 × 109/L) (OR 4.04), elevated CRP (>5 mg/L) (OR 3.04) and a radiological diagnosis (OR 8.0). Computerised tomography (CT) and ultrasound had sensitivity/specificity of 98%/47% and 35%/86%, respectively. The positive-predictive values were 85% for CT and 50% for ultrasound, and the negative-predictive values were 86% for CT and 77% for ultrasound. CONCLUSION: Our study has highlighted the importance of utilising a combination of factors to improve the diagnostic certainty of AA. However, our routine practice data have shown different sensitivities and specificities of imaging in comparison to existing literature, resulting in a high NAR. Further real-world data are needed to understand whether these differences from the existing data are seen in other clinical settings.

6.
Int J Hyperthermia ; 41(1): 2362998, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39128847

RESUMO

BACKGROUND: Focused ultrasound ablation surgery (FUAS) has been widely employed to treat patients with uterine fibroid (UF). This study aimed to estimate myometrial stiffness changes in patients who received FUAS for UFs or myomectomy (ME) and compare the recovery of surrounding myometrium between FUAS and ME groups. Our results may provide more evidence for guiding the proper conception timing in patients with UF. METHODS: This study enrolled 173 patients from May 2022 to August 2023. Shear wave elastography (SWE) was used to dynamically monitor myometrial elasticity changes in patients before and after surgery. Moreover, our study monitored and analyzed the stiffness changes in the targeted fibroid after FUAS, as well as in the myometrium around after FUAS or ME. RESULTS: The stiffness of the myometrium around the resected fibroid was significantly higher than at the preoperative level until 6 months. Conversely, the stiffness of the surrounding myometrium was only temporarily increased 1 day after FUAS. The comparison between FUAS and ME groups regarding the stiffness of the surrounding myometrium showed that nonsignificant differences were detected between the two groups before the treatment. The stiffness of the surrounding myometrium in the ME group was statistically significantly higher than that of the FUAS group 1 day as well as 1, 3, and 6 months after the treatment, respectively. CONCLUSION: The FUAS had less impact on the surrounding myometrium than the ME, which may be more conducive to the recovery of myometrial elasticity in patients with UF.


Assuntos
Elasticidade , Leiomioma , Miométrio , Miomectomia Uterina , Humanos , Feminino , Leiomioma/cirurgia , Leiomioma/diagnóstico por imagem , Miométrio/cirurgia , Miométrio/diagnóstico por imagem , Adulto , Miomectomia Uterina/métodos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Pessoa de Meia-Idade , Neoplasias Uterinas/cirurgia , Técnicas de Imagem por Elasticidade/métodos
7.
Sci Rep ; 14(1): 18370, 2024 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-39112604

RESUMO

The aim of this study was to evaluate the long-term efficacy of a single ultrasound-guided high-intensity focused ultrasound (US-HIFU) treatment in patients with breast fibroadenoma (FA) in terms of volume and pain reduction as well as palpation findings. From december 2013 until november 2014 27 women with a symptomatic FA were treated in one HIFU-session. Follow-up visits were performed after 7 days, 6 months and 1, 2, 3 and 5 years with clinical examination and ultrasound. One year after the procedure, a core needle biopsy of the residual lesion was offered. There was a significant volume reduction 6 months after HIFU from 1083.10 to 347.13 mm3 (p < 0.0001) with a mean volume reduction ratio (VRR) of 61.63%. Thereafter the FAs showed a further, but no longer significant decrease in size. One patient with an initial incomplete ablation and histologically confirmed persistent vital cells after 1 year showed a strong regrowth after 3 years. Excluding this patient from analysis, the mean VRR at months 12, 24, 36, and 60 was 86.44%, 94.44%, 94.90%, and 97.85%, respectively. Before HIFU, 59.26% of the patients had pain (22.33/100 VAS) which decreased to 6.56/100 after 12 months and remained reduced over the 5 year follow up period. A decrease in palpability from 85.19 to 7.69% was observed within 24 months. A single HIFU intervention let to a substantial reduction in size, pain, and palpability with its most potential effect during the first 12 months. Subsequently, the observed effect remained stable over a 5 year follow up period. Incomplete initial treatment was associated with the risk of regrowth.


Assuntos
Neoplasias da Mama , Fibroadenoma , Ablação por Ultrassom Focalizado de Alta Intensidade , Humanos , Fibroadenoma/terapia , Fibroadenoma/patologia , Fibroadenoma/cirurgia , Fibroadenoma/diagnóstico por imagem , Feminino , Neoplasias da Mama/terapia , Neoplasias da Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Adulto , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Seguimentos , Pessoa de Meia-Idade , Resultado do Tratamento , Adulto Jovem
8.
Cureus ; 16(7): e65248, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39184649

RESUMO

Echinococcosis, or hydatid disease, is a parasitic infection caused by a cestode from the Taeniidae family, mainly by Echinococcus multilocularis or granulosus. It is predominantly seen in the lungs or the liver. The hydatid disease rarely manifests as a palpable mass in the muscles. This study reports a case of a 70-year-old male who has presented with a swelling in the anterolateral aspect of his right upper thigh, which was progressive over the past two years. The swelling was initially painless and is now associated with pain. The clinical diagnosis of an abscess was suspected. The diagnosis of his swelling was later made as a hydatid cyst in a muscle of the thigh based on the imaging modalities, the ultrasound, and an MRI. The patient underwent surgical excision of the cyst, following which the diagnosis of a hydatid cyst was confirmed on the biopsy.

9.
Biomedicines ; 12(8)2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39200207

RESUMO

Functional electrical stimulation (FES) is a vital method in neurorehabilitation used to reanimate paralyzed muscles, enhance the size and strength of atrophied muscles, and reduce spasticity. FES often leads to increased muscle fatigue, necessitating careful monitoring of the patient's response. Ultrasound (US) imaging has been utilized to provide valuable insights into FES-induced fatigue by assessing changes in muscle thickness, stiffness, and strain. Current commercial FES electrodes lack sufficient US transparency, hindering the observation of muscle activity beneath the skin where the electrodes are placed. US-compatible electrodes are essential for accurate imaging and optimal FES performance, especially given the spatial constraints of conventional US probes and the need to monitor muscle areas directly beneath the electrodes. This study introduces specially designed body-conforming US-compatible FES (US-FES) electrodes constructed with a silver nanowire/polydimethylsiloxane (AgNW/PDMS) composite. We compared the performance of our body-conforming US-FES electrode with a commercial hydrogel electrode. The findings revealed that our US-FES electrode exhibited comparable conductivity and performance to the commercial one. Furthermore, US compatibility was investigated through phantom and in vivo tests, showing significant compatibility even during FES, unlike the commercial electrode. The results indicated that US-FES electrodes hold significant promise for the real-time monitoring of muscle activity during FES in clinical rehabilitative applications.

10.
Cureus ; 16(7): e65143, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39176363

RESUMO

Hydatid disease is a parasitic infection caused by a cestode from the Taeniidae family, by Echinococcus multilocularis or Echinococcus granulosus, predominantly occurring in the lungs and liver. Although the kidney can be involved in hydatid cysts, isolated kidney hydatidosis is very rare. Most cases present with non-specific complaints or remain asymptomatic for years. Hence, imaging is very useful in the diagnosis. Here, we report an isolated hydatid cyst involving the right kidney.

11.
Cureus ; 16(6): e61472, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38952597

RESUMO

This case report presents the diagnostic difficulties encountered by a 96-year-old woman with osteoporosis who experienced acute chest pain following minor trauma, eventually diagnosed with a sternal fracture. It highlights the nuanced presentation and diagnostic challenges associated with sternal fractures in older patients. Despite the prevalent use of chest radiography and computed tomography in acute trauma assessments, this case emphasizes their limitations, as both modalities initially failed to detect the sternal fracture. The successful identification of the fracture using ultrasound (US) underscores the utility of this modality in detecting subtle yet clinically significant injuries. This report advocates for a high index of suspicion for sternal fractures in older patients presenting with chest pain after minor trauma and suggests that US is a valuable, less invasive diagnostic tool. By illuminating the potential for minor trauma to cause major injury and the critical role of US in diagnosis, this case provides valuable insights into the management of sternal fractures in the geriatric population, urging clinicians to consider atypical presentations in diagnostic evaluations.

12.
Quant Imaging Med Surg ; 14(7): 4815-4824, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-39022240

RESUMO

Background: Intraplaque neovascularization (IPN) is a biomarker for vulnerable atherosclerotic plaques and can be effectively visualized via contrast-enhanced ultrasound (CEUS). Plaque elasticity is influenced by elements such as lipid core and fibrosis and can be quantitatively assessed on shear wave elastography (SWE). Studies combining the use of CEUS and SWE for the assessment of stroke risk are currently lacking. Our study thus aimed to determine the predictive value of IPN combined with plaque elasticity among patients with asymptomatic carotid plaque. Methods: Consecutive patients with mild carotid stenosis who underwent CEUS and SWE were retrospectively analyzed. IPN was graded according to the presence and location of microbubbles within the plaque, while plaque elasticity was measured in terms of mean shear wave velocity (SWV). All patients were followed up for 6 months to monitor the development of ischemic stroke. The predictive values of IPN and SWV, individually and in combination, were assessed. Results: A total of 121 patients were included, of whom 95 (78.5%) were male. The mean age was 63.1±10.7 years. Both grade 2 IPN [hazard ratio (HR) =2.37, 95% confidence interval (CI): 1.58-9.65; P=0.039] and SWV (HR =0.43, 95% CI: 0.20-0.95; P=0.038) were independently associated with future ischemic stroke events. The combined model demonstrated a significantly better predictive performance (HR =3.243, 95% CI: 1.87-6.17; P=0.027). Conclusions: The combination of IPN and SWV demonstrated significantly better predictive value for the risk of stroke. Our combined model thereby has the potential to guide the clinical stratification and management of patients with asymptomatic mild carotid stenosis.

13.
Emerg Radiol ; 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38941026

RESUMO

Pleural effusion is a very common clinical finding. Quantifying pleural effusion volume and its response to treatment over time has become increasingly important for clinicians, which is currently performed via computed tomography (CT) or drainage. To determine and compare ultrasonography (US), CT, and drainage agreements in pleural effusion volumetry. Protocol pre-registration was performed a priori at ( https://osf.io/rnugd/ ). We searched PubMed, Web of Science, Embase, and Cochrane Library for studies up to January 7, 2024. Risk of bias was assessed using Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2), QUADAS-C, and Consensus-based Standards for the selection of health Measurement Instruments (COSMIN). Volumetric performances of CT, US, and drainage in assessment of pleural effusion volume were evaluated through both aggregated data (AD) and individual participant data (IPD) analyses. Certainty of evidence was evaluated using Grading of Recommendations, Assessment, Development, and Evaluations (GRADE). Six studies were included with 446 pleural effusion lesions. AD results showed a perfect level of agreement with pooled Pearson correlation and intraclass correlation coefficient (ICC) of 0.933 and 0.948 between US and CT. IPD results demonstrated a high level of agreement between US and CT, with Finn's coefficient, ICC, concordance correlation coefficient (CCC), and Pearson correlation coefficient values of 0.856, 0.855, 0.854, and 0.860, respectively. Also, both results showed an overall perfect level of agreement between US and drainage. As for comparing the three combinations, US vs. CT and US vs. drainage were both superior to CT vs. drainage, suggesting the US is a good option for pleural effusion volumetric assessment. Ultrasound provides a highly reliable, to-the-point, cost-effective, and noninvasive method for the assessment of pleural effusion volume and is a great alternative to CT or drainage.

14.
J Clin Med ; 13(11)2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38892910

RESUMO

Background: Psoas muscle abscess (PMA) is an uncommon yet severe condition characterized by diagnostic and therapeutic challenges due to its varied etiology and nonspecific symptoms. This study aimed to evaluate the effectiveness and accuracy of various imaging techniques used in the image-guided percutaneous drainage (PD) of PMA. Methods: A systematic review was conducted following the PRISMA guidelines. We searched PubMed, Google Scholar, and Science Direct for studies published in English from 1998 onwards that reported on the use of PD in treating PMA, detailing outcomes and complications. Imaging modalities guiding PD were also examined. Results: We identified 1570 articles, selecting 39 for full review. Of these, 23 met the inclusion criteria; 19 were excluded due to unspecified PMA, absence of imaging guidance for PD, or inconclusive results. Eleven studies utilized computed tomography (CT) for PD, with six also using magnetic resonance imaging (MRI). Ten studies implemented ultrasound (US)-guided PD; variations in diagnostic imaging included combinations of US, CT, and MRI. A mixed approach using both CT and US was reported in two articles. Most studies using CT-guided PD showed complete success, while outcomes varied among those using US-guided PD. No studies employed MRI-guided PD. Conclusions: This review supports a multimodal approach for psoas abscess management, using MRI for diagnosis and CT for drainage guidance. We advocate for Cone Beam CT (CBCT)-MRI fusion techniques with navigation systems to enhance treatment precision and outcomes, particularly in complex cases with challenging abscess characteristics.

15.
Cureus ; 16(5): e59665, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38836161

RESUMO

Uterine arteriovenous malformation (AVM) is a potentially life-threatening condition. The vast majority of cases are acquired. Uterine artery embolization (UAE) is currently the treatment of choice for symptomatic women desiring future childbearing. However, there is no consensus on the number of UAE procedures that can be performed on an individual woman. We report a case of recurrent uterine AVM and discuss the challenges in diagnosis and management. A 35-year-old multiparous woman presented with heavy menstrual bleeding (HMB). She had been diagnosed with uterine AVM six years ago and had undergone two previous UAE procedures. Her abdominal examination revealed a healthy Pfannensteil scar. Bimanual examination revealed a normal-sized uterus that was firm, mobile, and fornices were free. Her haemoglobin was 10.2 g/dl. Greyscale two-dimensional ultrasound revealed a normal-sized uterus with multiple hypoechoic lesions in the myometrium. Colour Doppler ultrasound showed intense vascularity with multidirectional flow in the myometrium, suggestive of uterine AVM. In view of previous failed UAE procedures, she opted for a hysterectomy. A total abdominal hysterectomy with a bilateral salpingectomy was performed. Blood loss during the procedure was greater than average, and she was transfused with a unit of packed cells. Her post-operative course was uneventful. Histopathology confirmed the diagnosis of a uterine AVM. To conclude, the UAE is considered the treatment of choice for symptomatic women with uterine AVM desiring future childbearing. In cases of failure of UAE procedures, hysterectomy is therapeutic but may be associated with more than average blood loss.

16.
Transl Cancer Res ; 13(4): 1969-1979, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38737674

RESUMO

Background: The consistency of Breast Imaging Reporting and Data System (BI-RADS) classification among experienced radiologists is different, which is difficult for inexperienced radiologists to master. This study aims to explore the value of computer-aided diagnosis (CAD) (AI-SONIC breast automatic detection system) in the BI-RADS training for residents. Methods: A total of 12 residents who participated in the first year and the second year of standardized resident training in Ningbo No. 2 Hospital from May 2020 to May 2021 were randomly divided into 3 groups (Group 1, Group 2, Group 3) for BI-RADS training. They were asked to complete 2 tests and questionnaires at the beginning and end of the training. After the first test, the educational materials were given to the residents and reviewed during the breast imaging training month. Group 1 studied independently, Group 2 studied with CAD, and Group 3 was taught face-to-face by experts. The test scores and ultrasonographic descriptors of the residents were evaluated and compared with those of the radiology specialists. The trainees' confidence and recognition degree of CAD were investigated by questionnaire. Results: There was no statistical significance in the scores of residents in the first test among the 3 groups (P=0.637). After training and learning, the scores of all 3 groups of residents were improved in the second test (P=0.006). Group 2 (52±7.30) and Group 3 (54±5.16) scored significantly higher than Group 1 (38±3.65). The consistency of ultrasonographic descriptors and final assessments between the residents and senior radiologists were improved (κ3 > κ2 > κ1), with κ2 and κ3 >0.4 (moderately consistent with experts), and κ1 =0.225 (fairly agreed with experts). The results of the questionnaire showed that the trainees had increased confidence in BI-RADS classification, especially Group 2 (1.5 to 3.5) and Group 3 (1.25 to 3.75). All trainees agreed that CAD was helpful for BI-RADS learning (Likert scale score: 4.75 out of 5) and were willing to use CAD as an aid (4.5, max. 5). Conclusions: The AI-SONIC breast automatic detection system can help residents to quickly master BI-RADS, improve the consistency between residents and experts, and help to improve the confidence of residents in the classification of BI-RADS, which may have potential value in the BI-RADS training for radiology residents. Trial Registration: Chinese Clinical Trial Registry (ChiCTR2400081672).

17.
Quant Imaging Med Surg ; 14(5): 3519-3533, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38720854

RESUMO

Background: The Oncotype DX (ODX) recurrence score (RS), a 21-gene assay, has been proven to recognize patients at high risk of recurrence (RS ≥26) who would benefit from chemotherapy. However, it has limited availability and high costs. Our study thus aimed to identify ultrasound (US) imaging biomarkers and develop a prediction model for identifying patients with a high ODX RS. Methods: In this retrospective study, consecutive patients with T1-3N0-1M0 breast cancer who were hormone receptor positive and human epidermal growth factor receptor 2 (HER2) negative who had an available ODX RS were reviewed. Patients treated from May 2012 and December 2015 were placed into a training cohort, and those treated from January 2016 to January 2017 were placed in a validation cohort. Clinicopathologic data were collected, and preoperative US scans were analyzed. Univariable and multivariable regression analyses were performed to evaluate the independent predictors for a high-risk of breast cancer in the training cohort, and a nomogram was developed and evaluated with the area under the receiver operating characteristic curve (AUC), calibration curve, and decision curve analysis (DCA). Results: A total of 363 patients were in the training cohort and 160 in the validation cohort, with the proportion with a high RS (RS 26-100) being 14% and 13.1%, respectively. Echogenic halo, enhanced posterior echo, low level of progesterone receptor (PR), and high Ki-67 index were identified as independent risk factors for high RS (all P values <0.05). The nomogram was constructed based on the combined model, which showed a better discrimination ability than did the clinicopathological model [combined model: AUC =0.95, 95% confidence interval (CI): 0.93-0.97; clinicopathological model: AUC =0.89, 95% CI: 0.86-0.92; P=0.001] and greater clinical benefit according to DCA. Furthermore, the nomogram was found to be effective in the validation cohort (AUC =0.90, 95% CI: 0.84-0.94), especially in patients with stage T1N0M0 disease (AUC =0.91, 95% CI: 0.84-0.95). Conclusions: US features may serve as valuable imaging biomarkers for the prediction of high recurrence risk in patients with T1-3N0-1M0 breast cancer and hormone receptor (HR)-positive and HER2-negative status. A nomogram incorporating PR status, Ki-67 index, and US imaging biomarkers showed a good discrimination ability in the early selection of patients at high risk of recurrence, especially in those with stage T1N0M0 disease.

18.
Ultrasound Med Biol ; 50(8): 1224-1231, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38796340

RESUMO

OBJECTIVE: The main aim of this study was to determine whether the use of contrast-enhanced ultrasound (CEUS) could improve the categorization of suspicious breast lesions based on the Breast Imaging Reporting and Data System (BI-RADS), thereby reducing the number of benign breast lesions referred for biopsy. METHODS: This prospective study, conducted between January 2017 and December 2018, enrolled consenting patients from eight teaching hospitals in China, who had been diagnosed with solid breast lesions classified as BI-RADS 4 using conventional ultrasound. CEUS was performed within 1 wk of diagnosis for reclassification of breast lesions. Histopathological results obtained from core needle biopsies or surgical excision samples served as the reference standard. The simulated biopsy rate and cancer-to-biopsy yield were used to compare the accuracy of CEUS and conventional ultrasound (US). RESULTS: Among the 1490 lesions diagnosed as BI-RADS 4 with conventional ultrasound, 486 malignant and 1004 benign lesions were confirmed based on histology. Following CEUS, 2, 395, and 211 lesions were reclassified as CEUS-based BI-RADS 2, 3, and 5, respectively, while 882 (59%) remained as BI-RADS 4. The actual cancer-to-biopsy yield based on US was 32.6%, which increased to 43.4% when CEUS-based BI-RADS 4A was used as the cut-off point to recommend biopsy. The simulated biopsy rate decreased to 73.4%. Overall, in this preselected BI-RADS 4 population, only 2.5% (12/486) of malignant lesions would have been miscategorized as BI-RADS 3 using CEUS-based reclassification. The diagnostic accuracy, sensitivity, and specificity of contrast-enhanced ultrasound reclassification were 57.65%, 97.53%, and 38.35%, respectively. CONCLUSION: Our collective findings indicate that CEUS is a valuable tool in further triage of BI-RADS category 4 lesions and facilitates a reduction in the number of biopsies while increasing the cancer-to-biopsy yield.


Assuntos
Neoplasias da Mama , Mama , Meios de Contraste , Ultrassonografia Mamária , Humanos , Feminino , Estudos Prospectivos , Ultrassonografia Mamária/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Pessoa de Meia-Idade , Adulto , Mama/diagnóstico por imagem , Mama/patologia , Idoso , Aumento da Imagem/métodos , Adulto Jovem , Reprodutibilidade dos Testes , China
19.
Front Endocrinol (Lausanne) ; 15: 1350123, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38572472

RESUMO

Background: There is currently insufficient data to validate adult-based US risk stratification systems (RSSs) for the identification of malignant thyroid nodules in a pediatric population. Methods: From October 2016 and May 2023, 173 thyroid nodules of pediatric patients (age ≤ 18 years) with definitive pathology results and ultrasound (US) examination within 1 month before surgery or fine-needle aspiration (FNA) biopsy in our institution were enrolled in this study. The clinical and US characteristics of these nodules were retrospectively reviewed and categorized according to the ACR-TIRADS, C-TIRADS, and ATA guidelines. The diagnostic performance of US-based FNA criteria (original and simulating) of the three guidelines in thyroid cancer detection was estimated. Results: The three RSSs had similar AUC according to the categories(0.849-0.852, all P > 0.05). When combined with the original FNA criteria of the three RSSs to manage the nodules, the FNA rate of ACR-TIRADS and C-TIRADS were significantly less than ATA guidelines (53.18% vs. 64.63%, P < 0.05, and 52.60% vs. 64.63%, P < 0.05). The missed malignancy rate (MMR) and unnecessary FNA rate (UFR) of ATA guidelines (50.00%, 35.85%) was highest among the three RSSs, followed by the C-TIRADS (37.80%, 19.57%) and the ACR-TIRADS (37.04%, 19.57%). When nodules < 1 cm with the highest category in each RSS biopsied, that is when using the simulating FNA thresholds, the MMR was reduced overall (all P < 0.001), without a change in the UFR (all P > 0.05). All the three RSSs showed a substantial improvement in accuracy and malignant detection rate (all P < 0.05). Conclusion: The ACR-TIRADS, C-TIRADS, and ATA guidelines showed high missed malignancy rates when using their original recommended FNA criteria. When nodules < 1 cm with the highest category in each RSS biopsied, the missed malignancy rate of each RSS was decreased. Decreasing the FNA thresholds for highly suspicious malignant nodules may therefore be an effective means of managing malignant thyroid nodules in pediatric patients.


Assuntos
Neoplasias da Glândula Tireoide , Nódulo da Glândula Tireoide , Adulto , Humanos , Criança , Adolescente , Nódulo da Glândula Tireoide/epidemiologia , Estudos Retrospectivos , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/epidemiologia , Medição de Risco
20.
Quant Imaging Med Surg ; 14(4): 2946-2954, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38617152

RESUMO

Background: Despite the common use of ultrasound (US)-guided fine-needle aspiration (FNA) for axillary node (AN) in breast cancer patients, only a limited number of studies are available regarding the diagnostic performance of AN-FNA according to the suspicion level based on US findings. This study compares the outcomes of US-guided AN-FNA in breast cancer patients, differentiating between those undergoing staging and surveillance. Methods: A cross-sectional retrospective study with retrospective analysis was conducted on 767 consecutive AN-FNA procedures performed in 2017 at Samsung Medical Center in Seoul, with 654 for staging and 113 for surveillance in breast cancer patients. The radiologists performed axillary US and the specific finding was prospectively classified into the AN-reporting and data system (AN-RADS) category 3-5 before FNA. The malignancy rate of each category was evaluated. The chi-square test, with or without Bonferroni correction, or Fisher's exact test was used to compare the malignancy rates between the staging and surveillance groups for each category. Results: Among the 767 AN-FNAs, 424 (55.3%) were malignant. The malignancy rate was significantly higher in the staging group (59.5%) than in the surveillance group (31.0%, P<0.0001). The distribution of AN-RADS categories differed between the groups (P=0.015), with 4A being the most common. The malignancy rates in categories 3, 4A, 4B, 4C, and 5 were as follows: 5.6%, 36.0%, 77.4%, 87.7%, and 98.4% in the staging group, and 0.0%, 9.7%, 53.3%, 88.9%, and 100% in the surveillance group. The malignancy rate was significantly different between the two groups only in category 4A (P=0.0001). Conclusions: AN-FNA according to AN-RADS category appears to be an appropriate method for determination of axillary nodal status. Overall malignancy rate of AN-FNA in breast cancer patients was higher in the staging group than in the surveillance group. According to the suspicion level, the difference between two groups was significant only in category 4A.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA