Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 324
Filtrar
1.
Animals (Basel) ; 14(12)2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38929346

RESUMO

Continuous ovarian imaging has been proven to be a method for monitoring the development of follicles in vivo. The aim of this study was to evaluate the efficacy of combining ultrasound bio-microscopy (UBM) with an intravital window for follicle imaging in rabbits and to monitor the ovarian dynamic processes. New Zealand White female rabbits (n = 10) received ovarian translocation to a subcutaneous position. The ovarian tissue was sutured onto the abdominal muscles and covered with an intravital window for the continuous monitoring of the follicles using UBM. Results show that physiological changes (red blood cell and white blood cell counts, feed intake, and body weight change) in rabbits induced by surgery returned to normal physiological levels in one week. Furthermore, UBM could provide high-resolution imaging of follicles through the intravital window. Daily monitoring of ovarian dynamic processes for 6 days displayed variabilities in follicle counts and size. Collectively, these results provide a relatively new method to monitor ovarian dynamic processes and to understand the reproductive physiology of female rabbits.

2.
Int Ophthalmol ; 44(1): 283, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38922523

RESUMO

PURPOSE: To examine the rate of ciliary body detachment in patients with choroidal detachment following glaucoma surgery and its effect on the clinical course, management, and prognosis. METHODS: A prospective observational case-series study. Patients with choroidal detachment following glaucoma surgery in 2018-2019 were included. All underwent complete ophthalmological examination and ultrasound biomicroscopy for evaluation of the presence and extent of ciliary body detachment. Follow-up examinations including ultrasound biomicroscopy scans were performed at 1 week, 1 month, 3 months, and 6 months. RESULTS: Eight patients (8 eyes) were enrolled, 4 male and 4 female, of mean age 72 years (range 60-83). Five patients underwent trabeculectomy with mitomycin C (0.02%), which was combined with phacoemulsification cataract extraction in one; two underwent Ahmed glaucoma valve implantations, and one underwent ab-interno Xen45 gel stent implantation with mitomycin C (0.02%). The mean intraocular pressure was 26.0 ± 7.65 mmHg preoperatively, dropping to 6.9 ± 2.64 mmHg on first postoperative day one. Mean time from surgery to diagnosis of choroidal detachment was 11.6 ± 5.73 days. Ciliary body detachment was identified by ultrasound biomicroscopy in all patients, ranging between one and four quadrants. All patients were treated with topical steroids and cycloplegics; three (37.5%) received oral steroids. No surgical intervention for the choroidal or ciliary body detachments was indicated. CONCLUSIONS: In this real-world prospective study, concurrent ciliary body detachment was identified in all patients who presented with choroidal detachment following glaucoma surgery. This observation may deepen our understanding of the mechanism underlying the hypotony that is often seen after glaucoma surgery.


Assuntos
Efusões Coroides , Corpo Ciliar , Glaucoma , Pressão Intraocular , Humanos , Masculino , Feminino , Idoso , Estudos Prospectivos , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Pressão Intraocular/fisiologia , Efusões Coroides/diagnóstico , Efusões Coroides/etiologia , Glaucoma/cirurgia , Glaucoma/fisiopatologia , Glaucoma/complicações , Complicações Pós-Operatórias/diagnóstico , Microscopia Acústica , Seguimentos , Trabeculectomia/efeitos adversos , Trabeculectomia/métodos , Implantes para Drenagem de Glaucoma/efeitos adversos , Acuidade Visual , Doenças da Úvea/diagnóstico , Doenças da Úvea/etiologia , Tomografia de Coerência Óptica/métodos
3.
Ultrasound Med Biol ; 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38866649

RESUMO

OBJECTIVE: To compare anterior chamber depth (ACD) and lens thickness (LT) measurements by ultrasound biomicroscopy (UBM), A-scan cross vector (CV) overlay with UBM, and immersion A-scan technique in pediatric eyes. METHODS: This prospective comparative cohort study comprised 43 eyes of 25 pediatric participants (mean age: 2.3±2.2 y). UBM and immersion A-scan biometry were performed prior to dilation and intraocular surgery. ACD and LT were measured by UBM image analysis, A-scan CV UBM overlay, and immersion A-scan technique. RESULTS: ACD and LT measurements obtained using immersion A-scan were significantly greater than with UBM image analysis with mean differences of 0.52 mm and 0.62 mm, respectively (p < 0.001). Immersion A-scan and UBM measurements were moderately correlated (r = 0.70 and 0.64, p < 0.001). ACD and LT measurements obtained using CV overlay were not significantly different than UBM measurements and the values were strongly positively correlated (r = 0.95 and 0.93, p < 0.001). CONCLUSION: Immersion A-scan may overestimate ACD and LT compared to UBM in pediatric patients due to oblique placement of the A-scan probe relative to the optical axis. Supplemental use of UBM and/or CV overlay is indicated to improve measurement accuracy in pediatric patients who cannot reliably fixate due to the ability to confirm proper alignment of the probe with the pupil by visualizing the anterior segment.

4.
Ultrasound Med Biol ; 50(8): 1262-1272, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38777640

RESUMO

OBJECTIVE: This study aimed to develop and evaluate a deep learning-based model that could automatically measure anterior segment (AS) parameters on preoperative ultrasound biomicroscopy (UBM) images of implantable Collamer lens (ICL) surgery candidates. METHODS: A total of 1164 panoramic UBM images were preoperatively obtained from 321 patients who received ICL surgery in the Eye Center of Renmin Hospital of Wuhan University (Wuhan, China) to develop an imaging database. First, the UNet++ network was utilized to segment AS tissues automatically, such as corneal lens and iris. In addition, image processing techniques and geometric localization algorithms were developed to automatically identify the anatomical landmarks (ALs) of pupil diameter (PD), anterior chamber depth (ACD), angle-to-angle distance (ATA), and sulcus-to-sulcus distance (STS). Based on the results of the latter two processes, PD, ACD, ATA, and STS can be measured. Meanwhile, an external dataset of 294 images from Huangshi Aier Eye Hospital was employed to further assess the model's performance in other center. Lastly, a subset of 100 random images from the external test set was chosen to compare the performance of the model with senior experts. RESULTS: Whether in the internal test dataset or external test dataset, using manual labeling as the reference standard, the models achieved a mean Dice coefficient exceeding 0.880. Additionally, the intra-class correlation coefficients (ICCs) of ALs' coordinates were all greater than 0.947, and the percentage of Euclidean distance distribution of ALs within 250 µm was over 95.24%.While the ICCs for PD, ACD, ATA, and STS were greater than 0.957, furthermore, the average relative error (ARE) of PD, ACD, ATA, and STS were below 2.41%. In terms of human versus machine performance, the ICCs between the measurements performed by the model and those by senior experts were all greater than 0.931. CONCLUSION: A deep learning-based model could measure AS parameters using UBM images of ICL candidates, and exhibited a performance similar to that of a senior ophthalmologist.


Assuntos
Segmento Anterior do Olho , Aprendizado Profundo , Microscopia Acústica , Humanos , Microscopia Acústica/métodos , Segmento Anterior do Olho/diagnóstico por imagem , Masculino , Feminino , Adulto , Lentes Intraoculares Fácicas , Implante de Lente Intraocular , Adulto Jovem , Pessoa de Meia-Idade , Processamento de Imagem Assistida por Computador/métodos
5.
Ultrasound Med Biol ; 50(8): 1240-1246, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38806337

RESUMO

PURPOSE: To define the regular upper eyelid anatomy and their changes during dynamic motion using ultrasonographically depicted structures. DESIGN: A cross-sectional study. METHODS: High-resolution ultrasound biomicroscopy (50MHz) was performed on 84 upper eyelids of 42 healthy volunteers without evidence of eyelid conditions. The skin-orbicularis oculi complex (SOOC), levator aponeurosis, and Müller's muscle-conjunctival complex were imaged. The thickness of these structures was measured in primary gaze and downgaze positions. RESULTS: SOOC and levator aponeurosis thickness was bigger with eyes open than with eyes closed (p < 0.01). With eyes closed, the thickness of SOOC on the pupillary midline and levator aponeurosis was positively correlated with age (p < 0.05, p < 0.01, respectively), and the thickness of levator aponeurosis and SOOC on the pupil midline was also positively correlated with BMI index (p < 0.05). Similarly, SOOC thickness on the medial and lateral canthus line is also positively correlated with BMI index and age (p < 0.05, p < 0.01, respectively). As for the differences between genders, the mean thickness of SOOC and levator aponeurosis was statistically different (p < 0.05, respectively). The magnitude of levator aponeurosis thickness in men varied more than in women in different ocular positions (p < 0.05). All measurements had an intramethod between 0.624 and 0.792, and inter-rater ICC and intrarater ICC between 0.748 and 0.850. CONCLUSIONS: Ultrasound biomicroscopy represents a noninvasive tool for the visualization of upper eyelid morphology. Expanding its application can help to understand the dynamics of upper eyelid physiological movement, aging, and disease research in different populations and evaluate surgical outcomes.


Assuntos
Pálpebras , Microscopia Acústica , Humanos , Masculino , Feminino , Pálpebras/diagnóstico por imagem , Pálpebras/anatomia & histologia , Pálpebras/fisiologia , Microscopia Acústica/métodos , Adulto , Estudos Transversais , Pessoa de Meia-Idade , Adulto Jovem , Idoso , Valores de Referência
6.
Expert Rev Med Devices ; 21(5): 439-446, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38803101

RESUMO

OBJECTIVES: Differentiation of iris and ciliary body lesions as benign or malignant and cystic or solid is important. The aim of this study was to compare anterior segment swept-source optical coherence tomography (AS SS-OCT) and ultrasound biomicroscopy (UBM) findings in iris and ciliary body tumors. RESEARCH DESIGN AND METHODS: Forty-two eyes of 38 cases with iris and ciliary body tumors imaged with UBM and AS SS-OCT between September 2018 and September 2023 were evaluated retrospectively. RESULTS: Of 42 eyes, 14 had melanoma, 14 iris pigment epithelial (IPE) cysts, 7 nevi, 3 Lisch nodules, 2 iris stromal cysts, 1 pars plana cysts, and 1 iris mammillations. An equivalent (100%) visualization of the anterior tumor margin was obtained with both techniques. Compared to AS SS-OCT, UBM was superior for posterior margin visualization in melanocytic tumors and IPE cysts. Bland-Altman plots demonstrated good agreement between UBM and AS SS-OCT for melanocytic tumors < 2.5 mm in base diameter and < 2 mm in thickness. CONCLUSIONS: Although, UBM is the gold standard for ciliary body and iridociliary tumors. AS SS-OCT should be considered as an excellent alternative to UBM, especially in minimally elevated iris lesions.


Assuntos
Corpo Ciliar , Microscopia Acústica , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Microscopia Acústica/métodos , Corpo Ciliar/diagnóstico por imagem , Corpo Ciliar/patologia , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Estudos Retrospectivos , Idoso , Neoplasias Uveais/diagnóstico por imagem , Neoplasias Uveais/patologia , Segmento Anterior do Olho/diagnóstico por imagem , Segmento Anterior do Olho/patologia , Neoplasias da Íris/diagnóstico por imagem , Adulto Jovem , Doenças da Íris/diagnóstico por imagem , Iris/diagnóstico por imagem , Iris/patologia , Adolescente
7.
Front Vet Sci ; 11: 1366997, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38784657

RESUMO

Introduction: This study investigates the relationship between ciliary muscle dynamics, thickness, and the regulation of intraocular pressure (IOP), focusing on the progression of cataracts and changes post-phacoemulsification. It explores how these factors impact canine ocular health, particularly in the context of cataract development and subsequent surgical intervention. Materials and methods: Data was collected using Ultrasound Biomicroscopy (UBM) from dogs at the Veterinary Medical Teaching Hospital of Chungbuk National University, Korea. The study involved 57 eyes from 35 dogs, categorized into five groups: 13 normal eyes, 14 with incipient cataracts, 12 with immature cataracts, 6 with mature cataracts, and 12 post-phacoemulsification. UBM measurements assessed various ciliary muscle parameters including ciliary body axial length (CBAXL), ciliary process-sclera angle (CPSA), longitudinal fibers of ciliary muscle thickness (Lf-CMT), and longitudinal and radial fibers of ciliary muscle thickness (LRf-CMT). Results: Findings indicated a decrease in CBAXL and an increase in Lf-CMT as cataracts progressed in severity. Post-phacoemulsification, there was a notable increase in CBAXL and a decrease in CPSA, Lf-CMT, and LRf-CMT, compared to both cataractous and normal eyes. Regression analysis revealed a significant positive association between CBAXL and IOP, alongside a negative association between Lf-CMT and IOP. These findings suggest that variations in ciliary muscle dynamics and thickness, as influenced by cataract progression and phacoemulsification, have distinct impacts on intraocular pressure. Discussion: The study proposes that phacoemulsification leads to ciliary muscle contraction, causing an inward and anterior movement of the ciliary muscle. This movement results in the narrowing of the ciliary cleft and constriction of the unconventional outflow pathway, potentially causing an increased risk of glaucoma post-surgery. Our research contributes to understanding the anatomical and physiological changes in the canine eye following cataract surgery and underscores the importance of monitoring IOP and ciliary muscle dynamics in these patients.

8.
Eur J Ophthalmol ; : 11206721241252476, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38693770

RESUMO

PURPOSES: To investigate the features of the anterior segment structures in neovascular glaucoma (NVG) and analyze its differences from primary angle-closure glaucoma (PACG). METHODS: This study included patients who were first diagnosed with monocular NVG and PACG at the Affiliated Eye Hospital of Nanchang University during August 2019 to June 2022. Ultrasound biomicroscopy (UBM) was used to measure the anterior segment parameters of those eyes, including anterior chamber depth (ACD), anterior chamber width (ACW), anterior chamber area (ACA), iris area (IA), maximum iris thickness (ITMAX), middle iris thickness (ITMID), iris curvature (IC), lens vault (LV), angle opening distance (AOD500), trabecular iris angle (TIA500), trabecular-iris space area (TISA500) and peripheral anterior synechia (PAS) length. RESULTS: In this study, paired samples t-test showed that IA [1.170(0.324) mm2], ITMAX [0.368(0.079) mm], ITMID [0.280(0.062) mm] and IC [0.147(0.037) mm] of NVG were smaller than F-NVG [2.058(0.195) mm2, 0.611(0.045) mm, 0.415(0.049) mm and 0.272(0.077) mm], the AOD500, TIA500, and TISA500 of NVG were also smaller than F-NVG. Independent samples t-test showed that ACD [2.349(0.350) mm] and ACA [16.326(3.547) mm2] of NVG were larger than PACG [1.971(0.240) mm, 12.030(1.860) mm2], but the IA [1.170(0.324) mm2], ITMAX [0.368(0.079) mm], ITMID [0.280(0.062) mm], IC [0.147(0.037) mm] and LV [0.436(0.172 mm)] were smaller than PACG [1.740(0.294) mm2, 0.548(0.084) mm, 0.404(0.065) mm, 0.283(0.060) mm and 0.737(0.196) mm]. Among the 16 patients with 360° angle-closure NVG, the PAS length was 0.834 (0.326) mm, which exceeded the Schwalbe line. CONCLUSION: In NVG, the iris is atrophied, thinned, and straight, while the ACD is normal or slightly shallow. In 360° angle-closure NVG, the PAS length exceeds the Schwalbe line, presenting a pseudo angle phenomenon and a hockey stick sign. Notably, the anterior segment structure morphology of NVG exhibit differences from those of PACG.

9.
J Am Vet Med Assoc ; : 1-8, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38821111

RESUMO

OBJECTIVE: To determine the predictive value of corneal ultrasound biomicroscopy (UBM) findings for the outcome of equine corneal disease. ANIMALS: 46 horses with a clinical diagnosis of either infectious ulcerative keratitis or stromal abscess. METHODS: Corneal UBM (VevoMD; UHF70; VisualSonics) of horses with infectious corneal disease presenting to the North Carolina State University Equine Ophthalmology Service from 2019 to 2023 were evaluated. Size and depth of lesion, presence of Descemet membrane disruption (DMD), corneal thickness, and aqueous humor cell counts (AHCC) were assessed. Comparisons of UBM and clinical exam findings, presence of infectious organisms, and outcome (healed or enucleated) were performed. RESULTS: The UBMs from 46 horses were evaluated. Increased AHCC was significantly associated with increased size and depth of corneal lesions on UBM but not with DMD. Deep lesions and DMD were significantly associated with an enucleation outcome. Horses treated with systemic antibiotics had significantly lower AHCC on UBM, but there were no differences in AHCC with the use of other systemic or topical medications. There was no significant correlation between infectious disease results, clinical findings (aqueous flare or cells), outcome, and UBM AHCC. CLINICAL RELEVANCE: Parameters on UBM, such as depth of lesion, DMD, and AHCC, may be useful diagnostic and prognostic tools to augment the ophthalmic exam of horses with corneal disease. The UBM findings of deep corneal lesions and DMD suggest a poor prognosis and warrant aggressive surgical intervention.

10.
Korean J Ophthalmol ; 38(3): 227-235, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38665113

RESUMO

PURPOSE: In the present study, we introduce human lacrimal gland imaging using an ultrasound biomicroscopy (UBM) with a soft cover and show their findings. METHODS: The representative UBM findings of palpebral lobes in seven subjects (four with non-Sjögren dry eye syndrome, one with Sjögren syndrome, and two healthy subjects) were described in this study. To prolapse the palpebral lobe, the examiner pulled the temporal part of the upper eyelid in the superotemporal direction and directed the subject to look in the inferonasal direction. We scanned the palpebral lobes longitudinally and transversely using UBM. We used an Aviso UBM with a 50 MHz linear probe and ClearScan. RESULTS: In UBM of two healthy subjects, the echogenicity of the lacrimal gland was lower than that of the sclera and homogeneous. But the parenchyma of a patient with Sjögren dry eye syndrome was quite inhomogeneous compared to the healthy subjects. In two patients with dry eye syndrome, we were able to observe some lobules in the parenchyma. We could find excretory ducts running parallel at the surface of the longitudinal section in some subjects. In the longitudinal UBM scan of a subject, we observed a tubular structure at a depth of 1,500 µm that was considered a blood vessel. It ran from the superonasal to the inferotemporal direction. In a subject, we observed a large cyst beneath the conjunctiva. CONCLUSIONS: Lacrimal gland imaging using UBM has both advantages of optical coherence tomography and sonography, and could be useful for evaluating dry eye syndrome.


Assuntos
Aparelho Lacrimal , Microscopia Acústica , Humanos , Microscopia Acústica/métodos , Aparelho Lacrimal/diagnóstico por imagem , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/diagnóstico por imagem , Idoso , Síndrome de Sjogren/diagnóstico por imagem , Síndrome de Sjogren/diagnóstico
11.
J Vitreoretin Dis ; 8(2): 173-180, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38465360

RESUMO

Purpose:To describe the visual outcomes and problems that resulted from surgical treatment of nanophthalmic complete retinal detachment (RD) with retina-lens contact. Methods: A multicenter retrospective case series with deep sclerectomy as a treatment was performed. Results: Five cases had extensive deep sclerectomies, 3 with intended drainage of subretinal fluid (SRF). The RD resolved 1 week postoperatively in 4 cases and within 1 month in 1 case. The visual acuity improved from light perception to a median of 20/100. Three cases had longstanding lens touch beyond 1 year and improved VA to 20/100, 20/150, and hand motions, respectively. Complications included focal lens dialysis in 2 cases (passive drainage of SRF) and lens or intraocular lens dislocation in 1 case each (active drainage of SRF). Ultrasound biomicroscopy and anterior optical coherence tomography showed a very narrow angle and short zonules. Conclusions: Deep sclerectomy results in good anatomic and functional improvements in advanced cases of nanophthalmos exudative detachment, which is often considered to be incurable.

12.
Am J Vet Res ; 85(5)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38428156

RESUMO

OBJECTIVE: To assess the characteristics of blebs formed after Ahmed glaucoma valve (AGV) surgery in dogs using ultrasound biomicroscopy (UBM) and to analyze their correlation with postoperative intraocular pressure (IOP). ANIMALS: 16 eyes (13 dogs) were diagnosed with primary angle-closure glaucoma and were followed up after AGV surgery from June 2021 to September 2023. METHODS: In this prospective study, UBM examinations were performed to assess bleb characteristics, including bleb wall thickness and reflectivity. IOP at the time of UBM imaging and the duration from AGV surgery to UBM imaging were recorded. Histological examination of an enucleated eye removed due to uncontrolled IOP leading to blindness was also conducted. RESULTS: A significant correlation was observed between IOP and relative reflectivity (Pearson r = 0.60; P = .01), and a negative correlation was observed between bleb wall thickness and relative reflectivity (Pearson r = -0.72; P = .002). No significant correlation was observed between the duration from AGV surgery to UBM imaging and either bleb wall thickness or relative reflectivity, respectively. Histological examination of the enucleated eye revealed collagen-rich fibrous encapsulation of the bleb wall, including myofibroblasts that exhibited positive α-smooth muscle actin immunostaining. CLINICAL RELEVANCE: In dogs that underwent AGV surgery, less dense, thick-walled blebs on UBM tended to maintain IOP within the normal range. However, denser, thinner-walled blebs showed IOP levels above the normal range despite the use of antiglaucoma medications. UBM is a useful tool for evaluating bleb characteristics and their influence on IOP regulation after AGV surgery in dogs.


Assuntos
Doenças do Cão , Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Fechado , Pressão Intraocular , Microscopia Acústica , Animais , Cães , Doenças do Cão/cirurgia , Doenças do Cão/diagnóstico por imagem , Microscopia Acústica/veterinária , Glaucoma de Ângulo Fechado/veterinária , Glaucoma de Ângulo Fechado/cirurgia , Feminino , Estudos Prospectivos , Masculino , Glaucoma/veterinária , Glaucoma/cirurgia , Glaucoma/diagnóstico por imagem
13.
Vestn Oftalmol ; 140(1): 11-18, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38450461

RESUMO

Analysis of lens changes in Marfan syndrome (MS), in addition to assessing the position of the lens itself, should include the possibility of examining its supporting and accommodative components (ciliary zonule and ciliary body), or what can be called the entire anatomical complex of the lens. Optical methods of studying the structures of the anterior segment of the eye, due to iris opacity, allow only to analyze the state of the lens within the natural or medically enlarged pupil width. Visualization of the structures located behind the iris is possible with the use of radiation diagnostic methods, in particular ultrasound biomicroscopy (UBM). PURPOSE: This study assesses the state of the anatomical complex of the lens in MS using UBM. MATERIAL AND METHODS: The study was carried out on clinical material previously used by us to analyze changes in the fibrous membrane of the eye in MS. At the first stage, the main (19 patients with MS, 38 eyes) and the control (24 patients with myopia, 48 eyes) groups were formed for comparative evaluation. The formed groups were standardized according to the age of the patients and the axial length of the eye. At the second stage, patients with MS were divided into subgroups depending on the absence or presence of biomicroscopic signs of ectopia lentis (22 and 16 eyes, respectively). For UBM, an ultrasound linear sensor with a scanning frequency of 50 MHz was used (Aviso device, Quantel Medical, France). Various biometric UBM indicators were determined: lens thickness, diameter of the lens, lens-axial length factor, iris-lens angle, iris-lens contact distance, posterior chamber depth, length of the fibers of ciliary zonule, thickness of the ciliary body, sclera-ciliary process angle. RESULTS: There are changes in the anatomical complex of the lens as a whole in MS (in the lens itself, the ciliary zonule, and the ciliary body), which are characterized by an increase in lens thickness and a decrease in the diameter of the lens, an increase in the length of the fibers of the ciliary zonule and a decrease in the thickness of the ciliary body. At the same time, the displacement of the lens detected by optical biomicroscopy (ectopia lentis) can be considered as an advanced stage of changes in the anatomical complex of the lens. CONCLUSION: UBM provides the possibility of full-fledged visualization of all components of the anatomical complex of the lens in terms of both diagnostics, and monitoring of changes in MS. The question of the advisability of including this method in the algorithm for diagnosing ocular manifestations in order to verify the MS remains open. Possible obstacles may be, on the one hand, related to the need for special and expensive equipment, and on the other hand, the absence of a generally accepted «normal¼ values of UBM indicators of the anatomical complex of the lens.


Assuntos
Ectopia do Cristalino , Cristalino , Lentes , Síndrome de Marfan , Humanos , Ectopia do Cristalino/diagnóstico , Ectopia do Cristalino/etiologia , Síndrome de Marfan/complicações , Síndrome de Marfan/diagnóstico , Cristalino/diagnóstico por imagem , Iris
14.
Diagnostics (Basel) ; 14(6)2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38535059

RESUMO

Ocular health is currently a major concern for astronauts on current and future long-duration spaceflight missions. Spaceflight-associated neuro-ocular syndrome (SANS) is a collection of ophthalmic and neurologic findings that is one potential physiologic barrier to interplanetary spaceflight. Since its initial report in 2011, our understanding of SANS has advanced considerably, with a primary focus on posterior ocular imaging including fundus photography and optical coherence tomography. However, there may be changes to the anterior segment that have not been identified. Additional concerns to ocular health in space include corneal damage and radiation-induced cataract formation. Given these concerns, precision anterior segment imaging of the eye would be a valuable addition to future long-duration spaceflights. The purpose of this paper is to review ultrasound biomicroscopy (UBM) and its potential as a noninvasive, efficient imaging modality for spaceflight. The analysis of UBM for spaceflight is not well defined in the literature, and such technology may help to provide further insights into the overall anatomical changes in the eye in microgravity.

15.
Eur J Ophthalmol ; : 11206721241229468, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38303122

RESUMO

PURPOSE: To evaluate the incidence and causes of intraocular lens (IOL) tilt and changes in anterior chamber angle after secondary IOL sulcus implantation following congenital cataract removal. METHODS: A retrospective observational study was conducted on children who underwent secondary sulcus IOL implantation following pediatric cataract removal in the period from 2017-2020 in Cairo university Hospitals. Children were examined for IOL position, centration, and tilt. Intraocular pressure (IOP) measurement, fundus and gonioscopic examination was performed. Ultrasound biomicroscopy (UBM) was performed on both eyes in children with clinically detected tilt. RESULTS: Ciliary sulcus secondary IOL implantation was performed in 102 eyes (57 children). IOL tilt was detected clinically in 16 eyes of 14 children (15.7%). UBM showed clinically undetected tilt in the fellow eye in additional 4 eyes. The mean angle of tilt was 12.8 ± 3.9° in clinically detected tilt compared to 7.5 ± 1.2° in UBM detected tilt. Mean anterior chamber depth (ACD) was 2.4 ± 0.5 mm IOP was >21 mmHg in 1.9% of eyes. Narrowing of the anterior chamber angle (ACA) after sulcus implantation occurred in 40% of eyes with open angle. Sulcus proliferations and obliterated sulcus were detected in all 20 eyes. Sommering's ring was found in 7 eyes (35%). Axial length, corneal diameter, and presence of persistent fetal vasculature did not affect IOL position. CONCLUSION: The presence of residual lens matter or an obliterated ciliary sulcus is associated with a higher incidence of IOL malposition following ciliary sulcus implantation.

16.
Cureus ; 16(1): e52578, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38249646

RESUMO

Anterior segment tumours of the eye are relatively rare but can pose significant morbidity and mortality. We conducted a literature review to compare the performance of ultrasound biomicroscopy to anterior segment optical coherence tomography in the imaging of these tumours. A total of seven studies were included accounting for a cumulative 1,114 eyes. Ultrasound biomicroscopy has traditionally formed, and remains, the mainstay of tumour imaging due to its ability to penetrate pigmented lesions and delineate the posterior border of tumours, and the current evidence supports this.

17.
Clin Exp Ophthalmol ; 52(2): 186-206, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38214059

RESUMO

Ultrasound biomicroscopy (UBM) is an invaluable investigation for imaging anterior segment structures. Although it is operator-dependent and time consuming, unlike optical-based imaging techniques, it is able to image structures posterior to the iris, such as the zonules, ciliary body and part of the pars plana. It is especially useful in advanced cataracts, traumatic cataracts, subluxed lenses, posterior polar cataracts, and congenital and developmental anomalies affecting the anterior segment. It provides diagnostic information in eyes with complex cataracts or intraocular lens (IOL)-related pathology, and aids in surgical planning in order to minimise complications. In this review, we describe the UBM features of various lenticular pathologies and demonstrate its application in the diagnosis and surgical management of lens and IOL-related pathologies.


Assuntos
Extração de Catarata , Catarata , Lentes Intraoculares , Humanos , Microscopia Acústica/métodos , Implante de Lente Intraocular/métodos , Catarata/diagnóstico , Extração de Catarata/métodos
18.
BMC Ophthalmol ; 24(1): 34, 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38263030

RESUMO

BACKGROUND: The structural features have an impact on the surgical prognosis for congenital corneal opacity (CCO). The structural classification system of CCO, however, is lacking. Based on data from ultrasound biomicroscopy (UBM) findings in infants and toddlers with CCO, this research proposed a classification system for the anterior segment structure severity. METHODS: Medical records, preoperative UBM images and slit-lamp photographs of infants and toddlers diagnosed with CCO at University Third Hospital between December 2018 and June 2022 were reviewed. According to the anterior segment structural features observed in UBM images, eyes were classified as follows: U1, opaque cornea only; U2, central anterior synechia; U3, peripheral anterior synechia combined with angle closure; and U4, aniridia or lens anomaly. The opacity appearance and corneal vascularization density observed in slit-lamp photographs were assigned grades according to previous studies. The extent of vascularization was also recorded. The corresponding intraocular anomaly classifications and ocular surface lesion severity were analysed. RESULTS: Among 81 eyes (65 patients), 41 (50.6%) were right eyes, and 40 (49.4%) were left eyes. The median age at examination was 6.91 months (n = 81, 1.00, 34.00). Two (2.5%) of the 81 eyes were classified as U1, 20 (24.7%) as U2, 22 (27.2%) as U3a, 11 (13.6%) as U3b and 26 (32.1%) as U4. Bilateral CCO eyes had more severe UBM classifications (P = 0.019), more severe dysgenesis (P = 0.012) and a larger angle closure (P = 0.009). Eyes with more severe UBM classifications had higher opacity grades (P = 0.003) and vascularization grades (P = 0.014) and a larger vascularization extent (P = 0.001). Eyes with dysgenesis had higher haze grades (P = 0.012) and more severe vascularization (P = 0.003 for density; P = 0.008 for extent), while the angle closure range was related to haze grade (P = 0.013) and vascularization extent (P = 0.003). CONCLUSIONS: This classification method based on UBM and slit-lamp photography findings in the eyes of CCO infants and toddlers can truly reflect the degree of abnormality of the ocular surface and anterior segment and is correlated with the severity of ocular surface anomalies. This method might provide meaningful guidance for surgical procedure design and prognostic determinations for keratoplasty in CCO eyes.


Assuntos
Doenças da Córnea , Opacidade da Córnea , Anormalidades do Olho , Doenças da Íris , Lactente , Humanos , Pré-Escolar , Microscopia Acústica , Microscopia com Lâmpada de Fenda , Neovascularização Patológica , Córnea
19.
Med Phys ; 51(4): 3124-3129, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38055556

RESUMO

BACKGROUND: Ocular foreign bodies (OFBs) are a relatively common occurrence in ocular injuries, and a severe risk factor for vision disorders. They are notoriously challenging to identify and localize precisely to allow surgical removal, even with the most recent technological advancements. PURPOSE: To compare the efficiency of different imaging methods in detecting and localizing OFBs. METHODS: We conducted a retrospective analysis of the medical records of patients with OFBs, detected by ultrasound biomicroscopy (UBM) and confirmed during surgery. Patients who presented to our medical center between January 2016 and January 2022 and also underwent computed tomography (CT), X ray, and/or ocular B-scan ultrasonography (B-scans) were selected. RESULTS: This study included 134 patients with a history of ocular trauma and OFBs (mean age: 47.25 years, range: 8-78). The mean time interval from injury to UBM examination was 36.31 months (range: 0.2-120 months). Most OFBs were metallic (51.82%) or plant-based (25.37%); 22.39% of them were located in the sclera, 26.87% in the anterior chamber, and 23.88% in the ciliary body and iris. OFBs ranged in size from 0.10 to 6.67 mm (mean: 1.15 ± 1.10 mm). B-scans identified OFBs in 37 of the 119 patients examined (31.09%); CT in 52 of 84 patients (61.90%); and radiography in 29 of 50 patients (58.00%). Univariate and multivariate analyses determined that both CT and radiography showed low detection rates for plant-based versus non-plant-based OFBs (CT: p < 0.001; radiography: p = 0.007), small particles (<1.00 mm vs. >1.00 mm; CT: p = 0.001, radiography: p = 0.024), and with eyeball wall locations (vs. intraocular; CT: p < 0.001, radiography: p = 0.021). Similarly, B-scans were less efficient for plant-based and eyeball wall-located OFBs (both p = 0.001), whereas the difference based on dimensions was not significant (p = 0.118). CONCLUSIONS: CT, radiography, and B-scans showed lower detection rates for plant-based, small, and eyeball wall-located OFBs. Our findings strongly suggest that UBM could be a more adequate imaging modality when such OFBs are suspected.


Assuntos
Corpos Estranhos no Olho , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Corpos Estranhos no Olho/diagnóstico por imagem , Corpos Estranhos no Olho/etiologia , Corpos Estranhos no Olho/cirurgia , Microscopia Acústica , Ultrassonografia , Radiografia
20.
Graefes Arch Clin Exp Ophthalmol ; 262(4): 1245-1252, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37938376

RESUMO

PURPOSE: To evaluate the anterior segment structures using ultrasound biomicroscopy (UBM) in primary congenital glaucoma (PCG) and explore their correlation with disease severity and surgical outcomes. METHODS: Clinical information of PCG patients who underwent UBM prior to their first glaucoma surgeries from September 2014 to March 2021 were reviewed. The study included 214 UBM images of 154 PCG eyes and 60 fellow unaffected eyes. Anterior segment characteristics were analyzed. UBM parameters, including the iris thickness (IT) at variant distances from the pupil edge and iris root, anterior chamber depth (ACD), and pupil diameter (PD), were compared between two groups and their relationship with clinical factors and surgical outcomes were analyzed in PCG eyes. RESULTS: PCG eyes had unclear scleral spur, thin iris, wide anterior chamber angle, deep anterior chamber, rarefied ciliary body, elongated ciliary processes, and abnormal anterior iris insertion. ITs were thinner, ACD was deeper, and PD was larger in PCG eyes than fellow unaffected eyes (all P < 0.001). In PCG eyes, thinner ITs correlated with bilateral involvement and earlier age at presentation, and larger PD correlated with earlier age at presentation (P = 0.030) and higher intraocular pressure (P < 0.001). Thinner IT2 (P = 0.046) and larger PD (P = 0.049) were identified as risk factors for surgical failure. CONCLUSION: UBM is a powerful technique to exam anterior segment structures in PCG. The anatomical features are associated with disease severity and surgical outcomes, providing essential clinical insights.


Assuntos
Glaucoma de Ângulo Fechado , Glaucoma , Humanos , Microscopia Acústica/métodos , Corpo Ciliar/diagnóstico por imagem , Iris/diagnóstico por imagem , Glaucoma/diagnóstico , Glaucoma/cirurgia , Glaucoma/congênito , Gravidade do Paciente , Resultado do Tratamento , Glaucoma de Ângulo Fechado/cirurgia , Segmento Anterior do Olho/diagnóstico por imagem , Pressão Intraocular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...