Resultados 1 - 20 de 420
Filtrar
1.
Adv Healthc Mater ; : e2401436, 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38923231

RESUMO

Contrast-enhanced ultrasound (CEUS) plays a crucial role in cancer diagnosis. The use of ultrasound contrast agents (UCAs) is inevitable in CEUS. However, current applications of UCAs primarily focus on enhancing imaging quality of ultrasound contrast rather than serving as integrated platforms for both diagnosis and treatment in clinical settings. In this study, a novel UCA, termed NPs-DPPA(C3F8), is innovatively prepared using a combination of nanoprecipitation and ultrasound vibration methods. The DPPA lipid possesses inherent antiangiogenic and antitumor activities, and when combined with C3F8, it functions as a theranostic agent. Notably, the preparation of NPs-DPPA(C3F8) is straightforward, requiring only one hour from raw materials to the final product due to the use of a single material, DPPA. NPs-DPPA(C3F8) exhibits inherent antiangiogenic and biotherapeutic activities, effectively inhibiting triple-negative breast cancer (TNBC) angiogenesis and reducing VEGFA expression both in vitro and in vivo. Clinically, NPs-DPPA(C3F8) enables simultaneous real-time imaging, tumor assessment, and antitumor activity. Additionally, through ultrasound cavitation, NPs-DPPA(C3F8) can overcome the dense vascular walls to increase accumulation at the tumor site and facilitate internalization by tumor cells. The successful preparation of NPs-DPPA(C3F8) offers a novel approach for integrating clinical diagnosis and treatment of TNBC.

2.
Cardiovasc Intervent Radiol ; 47(7): 1000-1008, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38898149

RESUMO

PURPOSE: The visibility of biopsy needles in contrast-specific imaging mode can be improved by priming them with an ultrasound contrast agent (previously demonstrated in a phantom model/ex vivo). The purpose of this study was to validate this priming method in a porcine in vivo model. MATERIALS AND METHODS: Using a small syringe, full-core biopsy needles were primed with sulfur hexafluoride, an ultrasound contrast agent, with non-primed needles serving as controls (n = 30 + 30). Liver punctures were performed in a porcine model following intravenous administration of the same ultrasound contrast agent. Needle visibility, both in their entirety and at the tips, was evaluated in split-screen mode using contrast-specific imaging and B-mode (low mechanical index). The assessment included quantitative analysis, calculating the contrast-to-noise ratio, and qualitative evaluation through structured grading by three radiologists. RESULTS: After needle priming, the contrast-to-noise ratio was superior for the needle in its entirety in contrast-specific imaging mode (p < 0.001) and slightly inferior in B-mode (p = 0.008). No differences were observed for the needle tips in either imaging mode. Qualitatively, the needle visibility was deemed clinically superior after needle priming throughout in contrast-specific imaging mode (p < 0.001), whereas no clinically relevant differences in B-mode for either the needle in its entirety (p = 0.11) or the needle tip (p = 1) were observed. CONCLUSION: In this in vivo porcine liver model experiment, priming biopsy needles with ultrasound contrast agent improved needle visibility in contrast-specific imaging mode but slightly reduced it in B-mode. These findings support the method's use for biopsies requiring target visualization in contrast-specific imaging mode.


Assuntos
Meios de Contraste , Fígado , Agulhas , Animais , Suínos , Fígado/diagnóstico por imagem , Fígado/patologia , Ultrassonografia de Intervenção/métodos , Hexafluoreto de Enxofre/administração & dosagem , Biópsia por Agulha/métodos , Modelos Animais
3.
Phys Med Biol ; 69(13)2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38843808

RESUMO

Objective.Super-resolution ultrasonography offers the advantage of visualization of intricate microvasculature, which is crucial for disease diagnosis. Mapping of microvessels is possible by localizing microbubbles (MBs) that act as contrast agents and tracking their location. However, there are limitations such as the low detectability of MBs and the utilization of a diluted concentration of MBs, leading to the extension of the acquisition time. We aim to enhance the detectability of MBs to reduce the acquisition time of acoustic data necessary for mapping the microvessels.Approach.We propose utilizing phase patterned waves (PPWs) characterized by spatially patterned phase distributions in the incident beam to achieve this. In contrast to conventional ultrasound irradiation methods, this irradiation method alters bubble interactions, enhancing the oscillation response of MBs and generating more significant scattered waves from specific MBs. This enhances the detectability of MBs, thereby enabling the detection of MBs that were undetectable by the conventional method. The objective is to maximize the overall detection of bubbles by utilizing ultrasound imaging with additional PPWs, including the conventional method. In this paper, we apply PPWs to ultrasound imaging simulations considering bubble-bubble interactions to elucidate the characteristics of PPWs and demonstrate their efficacy by employing PPWs on MBs fixed in a phantom by the experiment.Main results.By utilizing two types of PPWs in addition to the conventional ultrasound irradiation method, we confirmed the detection of up to 93.3% more MBs compared to those detected using the conventional method alone.Significance.Ultrasound imaging using additional PPWs made it possible to increase the number of detected MBs, which is expected to improve the efficiency of bubble detection.


Assuntos
Microbolhas , Imagens de Fantasmas , Ultrassonografia , Ultrassonografia/métodos , Meios de Contraste/química
4.
Ultrasound Med Biol ; 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38876912

RESUMO

OBJECTIVE: Both microbubble ultrasound contrast agents and acoustic phase change droplets (APCD) have been explored in hepatocellular carcinoma (HCC). This work aimed to evaluate changes to the HCC microenvironment following either microbubble or APCD destruction in a syngeneic pre-clinical model. METHODS: Mouse RIL-175 HCC tumors were grown in the right flank of 64 immunocompetent mice. Pre-treatment, photoacoustic volumetric tumor oxygenation, and power Doppler measurements were obtained using a Vevo 3100 system (VisualSonics, Toronto, Canada). The experimental groups received a 0.1 mL bolus injection of either Definity ultrasound contrast agent (Lantheus Medical Imaging) or APCD fabricated by condensing Definity. Following injection, ultrasound destruction was performed using flash-replenishment sequences on a Sequoia with a 10L4 probe (Siemens) for the duration of enhancement. Tumor oxygenation and power Doppler measurements were then repeated immediately post-ultrasound treatment. Twenty-four hours post-treatment, animals were euthanized, and tumors were harvested and stained for CD31, Cleaved Caspase 3 and CD45. RESULTS: Imaging biomarkers demonstrated a significant reduction in percent vascularity following either microbubble or APCD destruction in the tumor microenvironment ( p < 0.022) but no significant changes in tumor oxygenation (p = 0.12). Similarly, immunohistochemistry data demonstrated a significant decrease in CD31 expression (p < 0.042) and an increase in apoptosis (p < 0.014) in tumors treated with destroyed microbubbles or APCD relative to controls. Finally, a significant increase in CD45 expression was observed in tumors treated with APCD (p = 0.046), indicating an increase in tumor immune response. CONCLUSION: Ultrasound-triggered destruction of both microbubbles and APCD reduces vascularity, increases apoptosis, and may also increase immune response in this HCC model.

5.
Int J Nanomedicine ; 19: 4651-4665, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38799698

RESUMO

Introduction: Recently, nanobubbles (NBs) have gained significant traction in the field of tumor diagnosis and treatment owing to their distinctive advantages. However, the application of NBs is limited due to their restricted size and singular reflection section, resulting in low ultrasonic reflection. Methods: We synthesized a nano-scale ultrasound contrast agent (IR783-SiO2NPs@NB) by encapsulating SiO2 nanoparticles in an IR783-labeled lipid shell using an improved film hydration method. We characterized its physicochemical properties, examined its microscopic morphology, evaluated its stability and cytotoxicity, and assessed its contrast-enhanced ultrasound imaging capability both in vitro and in vivo. Results: The results show that IR783-SiO2NPs@NB had a "donut-type" composite microstructure, exhibited uniform particle size distribution (637.2 ± 86.4 nm), demonstrated excellent stability (30 min), high biocompatibility, remarkable tumor specific binding efficiency (99.78%), and an exceptional contrast-enhanced ultrasound imaging capability. Conclusion: Our newly developed multiple scattering NBs with tumor targeting capacity have excellent contrast-enhanced imaging capability, and they show relatively long contrast enhancement duration in solid tumors, thus providing a new approach to the structural design of NBs.


Assuntos
Meios de Contraste , Nanopartículas , Tamanho da Partícula , Dióxido de Silício , Ultrassonografia , Meios de Contraste/química , Ultrassonografia/métodos , Animais , Nanopartículas/química , Dióxido de Silício/química , Humanos , Linhagem Celular Tumoral , Camundongos , Neoplasias/diagnóstico por imagem , Microbolhas , Camundongos Nus , Camundongos Endogâmicos BALB C , Indóis
6.
Ultrason Imaging ; 46(3): 178-185, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38622911

RESUMO

To evaluate the inter-observer variability and the intra-observer repeatability of pulmonary transit time (PTT) measurement using contrast-enhanced ultrasound (CEUS) in healthy rabbits, and assess the effects of dilution concentration of ultrasound contrast agents (UCAs) on PTT. Thirteen healthy rabbits were selected, and five concentrations UCAs of 1:200, 1:100, 1:50, 1:10, and 1:1 were injected into the right ear vein. Five digital loops were obtained from the apical 4-chamber view. Four sonographers obtained PTT by plotting the TIC of right atrium (RA) and left atrium (LA) at two time points (T1 and T2). The frame counts of the first appearance of UCAs in RA and LA had excellent inter-observer agreement, with intra-class correlations (ICC) of 0.996, 0.988, respectively. The agreement of PTT among four observers was all good at five different concentrations, with an ICC of 0.758-0.873. The reproducibility of PTT obtained by four observers at T1 and T2 was performed well, with ICC of 0.888-0.961. The median inter-observer variability across 13 rabbits was 6.5% and the median variability within 14 days for 4 observers was 1.9%, 1.7%, 2.2%, 1.9%, respectively; The PTT of 13 healthy rabbits is 1.01 ± 0.18 second. The difference of PTT between five concentrations is statistically significant. The PTT obtained by a concentration of 1:200 and 1:100 were higher than that of 1:1, while there were no significantly differences in PTT of a concentration of 1:1, 1:10, and 1:50. PTT measured by CEUS in rabbits is feasible, with excellent inter-observer and intra-observer reliability and reproducibility, and dilution concentration of UCAs influences PTT results.


Assuntos
Meios de Contraste , Estudos de Viabilidade , Variações Dependentes do Observador , Ultrassonografia , Animais , Coelhos , Reprodutibilidade dos Testes , Ultrassonografia/métodos , Hexafluoreto de Enxofre/farmacocinética , Circulação Pulmonar/fisiologia
7.
Ultrason Sonochem ; 104: 106831, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38428306

RESUMO

Ultrasonically excited microbubbles (MBs) have numerous applications in various fields, such as drug delivery, and imaging. Ultrasonically excited MBs are known to be nonlinear oscillators that generate secondary acoustic emissions in the media when excited by a primary ultrasound wave. The propagation of acoustic waves in the liquid is limited to the speed of sound, resulting in each MB receiving the primary and secondary waves at different times depending on their distance from the ultrasound source and the distance between MBs. These delays are referred to as primary and secondary delays, respectively. A previous study demonstrated that the inclusion of secondary delays in a model describing the interactions between MBs exposed to ultrasound results in an increase in the linear resonance frequency of MBs as they approach each other. This work investigates the impact of various MB properties on the change in linear resonance frequency resulting from changes in inter-bubble distances. The effects of shell properties, including the initial surface tension, surface dilatational viscosity of the shell monolayer, elastic compression modulus of the shell, and the initial radius of the MBs, are examined. MB size is a significant factor influencing the rate of linear resonance frequency increase with increasing concentration. Moreover, it is found that the shell properties of MBs play a negligible role in the rate of change in linear resonance frequency of MBs as the inter-bubble distances change.The findings of this study have implications for various applications of MBs in the biomedical field. By understanding the impact of inter-bubble distances and shell properties on the linear resonance frequency of MBs, the utilization of MBs in applications reliant on their resonant behavior can be optimized.

8.
Radiol Cardiothorac Imaging ; 6(1): e230153, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38358329

RESUMO

Purpose To investigate if the right ventricular (RV) systolic and left ventricular (LV) diastolic pressures can be obtained noninvasively using the subharmonic-aided pressure estimation (SHAPE) technique with Sonazoid microbubbles. Materials and Methods Individuals scheduled for a left and/or right heart catheterization were prospectively enrolled in this institutional review board-approved clinical trial from 2017 to 2020. A standard-of-care catheterization procedure was performed by advancing fluid-filled pressure catheters into the LV and aorta (n = 25) or RV (n = 22), and solid-state high-fidelity pressure catheters into the LV and aorta in a subset of participants (n = 18). Study participants received an infusion of Sonazoid microbubbles (GE HealthCare), and SHAPE data were acquired using a validated interface developed on a SonixTablet (BK Medical) US scanner, synchronously with the pressure catheter data. A conversion factor, derived using cuff-based pressure measurements with a SphygmoCor XCEL PWA (ATCOR) and subharmonic signal from the aorta, was used to convert the subharmonic signal into pressure values. Errors between the pressure measurements obtained using the SHAPE technique and pressure catheter were compared. Results The mean errors in pressure measurements obtained with the SHAPE technique relative to those of the fluid-filled pressure catheter were 1.6 mm Hg ± 1.5 [SD] (P = .85), 8.4 mm Hg ± 6.2 (P = .04), and 7.4 mm Hg ± 5.7 (P = .09) for RV systolic, LV minimum diastolic, and LV end-diastolic pressures, respectively. Relative to the measurements with the solid-state high-fidelity pressure catheter, the mean errors in LV minimum diastolic and LV end-diastolic pressures were 7.2 mm Hg ± 4.5 and 6.8 mm Hg ± 3.3 (P ≥ .44), respectively. Conclusion These results indicate that SHAPE with Sonazoid may have the potential to provide clinically relevant RV systolic and LV diastolic pressures. Keywords: Ultrasound-Contrast, Cardiac, Aorta, Left Ventricle, Right Ventricle ClinicalTrials.gov registration no.: NCT03245255 © RSNA, 2024.


Assuntos
Compostos Férricos , Ferro , Microbolhas , Óxidos , Humanos , Coração , Ventrículos do Coração
9.
Ultrasound J ; 16(1): 14, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38386209

RESUMO

BACKGROUND: Given the limited success rate and considerable challenges associated with conventional ultrasonography (US) guidance for percutaneous nephrostomy (PCN) in non-hydronephrotic kidneys, this study proposed a solution with ultrasound contrast agent to enhance the success rate and mitigate the difficulties. MATERIALS AND METHODS: From January 2017 to August 2023, a total of thirteen patients diagnosed with non-hydronephrotic kidney were included in the study. Following routine ultrasonography examination, no significant dilatation of the renal collecting system was observed. US-guided percutaneous nephrostomy PCN was performed with the assistance of ultrasound contrast agent (UCA). The patients were subsequently monitored to assess the improvement of symptoms and postoperative recovery. RESULTS: The success rate was found to be 100% for all patients (13/13) and kidneys (20/20). The average volume of UCA solution used was 19 ± 6.7 mL (range, 11-35 mL), while the mean duration of the operation was 18.92 ± 8.96 min (range, 7-36 min). A majority of the patients (12/13) underwent a single puncture procedure. Throughout the follow-up period, no serious complications were observed, and surgery resulted in significant alleviation of symptoms in all patients. CONCLUSION: The use of UCA-assisted US guidance PCN has been shown to be effective in achieving urinary diversion and alleviating associated clinical symptoms in non-hydronephrotic kidneys. In comparison to traditional methods, this approach demonstrates a high success rate and safety profile, while also offering a simplified operative procedure. Consequently, it presents a novel method and concept for managing non-hydronephrotic kidneys afflicted by urine leakage.

10.
Ultrason Imaging ; 46(2): 130-134, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38318708

RESUMO

Subharmonic aided pressure estimation (SHAPE) is a technique that utilizes subharmonic signals from microbubble contrast agents for pressure estimation. Validation of the SHAPE technique relies on synchronous measurements of in vivo pressures using contrast microbubbles and a pressure catheter (reference standard). For the guidance and placement of pressure catheter in vivo, iodinated contrast is used with fluoroscopy. Therefore, during data acquisition for validation studies of the SHAPE technique, both contrast microbubbles and iodinated contrast are present simultaneously within the vasculature. This study aims to elucidate the effects of iodinated contrast (Visipaque, GE HealthCare) on subharmonic signal amplitude from contrast microbubbles (Definity, Lantheus Medical Imaging, Inc.). In an acrylic water tank, 0.06 mL of Definity and varied amounts of Visipaque (0.14, 0.43, 0.85, and 1.70 mL) were added to 425 mL of deionized water. Ultrasound scanning was performed with a SonixTablet scanner (BK Medical Systems) using optimized parameters for SHAPE with Definity (ftransmit/receive = 3.0/1.5 MHz; chirp down pulse). Subharmonic data was acquired and analyzed at 9 different incident acoustic outputs (n = 3). Results showed an increase in subharmonic signal amplitude from Definity microbubbles in the presence of 0.14 mL Visipaque by 2.8 ± 1.3 dB (p < .001), no change with 0.85 mL Visipaque (0.7 ± 1.2 dB; p = .09) and a decrease in subharmonic amplitude in the presence of 1.70 mL Visipaque by 1.9 ± 0.7 dB (p < .001). While statistically significant effect on subharmonic signal amplitude of Definity microbubbles was noted due to the mixture, the magnitude of the effect was minimal (~2.8 dB) and unlikely to impact in vivo SHAPE measurements.


Assuntos
Meios de Contraste , Fluorocarbonos , Ácidos Tri-Iodobenzoicos , Água , Ultrassonografia/métodos
11.
ACS Appl Bio Mater ; 7(3): 1416-1428, 2024 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-38391247

RESUMO

Diabetes vasculopathy is a significant complication of diabetes mellitus (DM), and early identification and timely intervention can effectively slow the progression. Accumulating studies have shown that diabetes causes vascular complications directly or indirectly through a variety of mechanisms. Direct imaging of the endothelial molecular changes not only identifies the early stage of diabetes vasculopathy but also sheds light on the precise treatment. Targeted ultrasound contrast agent (UCA)-based ultrasound molecular imaging (UMI) can noninvasively detect the expression status of molecular biomarkers overexpressed in the vasculature, thereby being a potential strategy for the diagnosis and treatment response evaluation of DM. Amounts of efforts have been focused on identification of the molecular targets expressed in the vasculature, manufacturing strategies of the targeted UCA, and the clinical translation for the diagnosis and evaluation of therapeutic efficacy in both micro- and macrovasculopathy in DM. This review summarizes the latest research progress on endothelium-targeted UCA and discusses their promising future and challenges in diabetes vasculopathy theranostics.


Assuntos
Diabetes Mellitus , Angiopatias Diabéticas , Humanos , Diabetes Mellitus/diagnóstico por imagem , Angiopatias Diabéticas/diagnóstico por imagem , Angiopatias Diabéticas/etiologia , Angiopatias Diabéticas/terapia , Biomarcadores , Imagem Molecular/métodos
12.
Colloids Surf B Biointerfaces ; 234: 113705, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38194837

RESUMO

Hollow-core microstructured optical waveguides (HC-MOW) have recently emerged in sensing technologies, including the gas and liquid detection for industrial as well as clinical applications. Antiresonant HC-MOW provide capabilities for applications in refractive index (RI) sensing, while the long optical path for analyte-light interaction in HC-MOW leads to increased sensitivity of sensor based on Raman scattering signal measurements. In this study, we developed a two-in-one sensor device using HC-MOW for RI and Raman scattering detection. The performance of the sensor was evaluated by characterizing protein-copolymer multicomponent colloids, specifically, bovine serum albumin (BSA) and poly(N - vinyl-2 -pyrrolidone-co-acrylic acid) P(VP-AA) nano-sized complexes and microbubbles of the corresponding shell. Monocomponent solutions showed linear dependencies of RI and characteristic Raman peak intensities on mass concentration. Multicomponent Raman sensing of BSA@P(VP-AA) complexes and microbubbles revealed that changes in P(VP-AA) characteristic peak intensities can describe interactions between components needed to produce colloid systems. RI sensing of multicomponent colloids demonstrated linear dependence on total mass concentrations for BSA@P(VP-AA) complexes, while corresponding BSA@P(VP-AA) microbubbles can be detected with concentrations as high as 4.0 × 108 MB/mL. Therefore, the developed two-in-one sensor of RI and Raman scattering can be used the robust characterization of albumin-based colloids designed for therapeutic and diagnostic needs.


Assuntos
Refratometria , Análise Espectral Raman , Coloides
13.
Ultrasonics ; 138: 107244, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38237398

RESUMO

Fractional flow has been proposed for quantifying the degree of functional stenosis in cerebral arteries. Herein, subharmonic aided pressure estimation (SHAPE) combined with plane wave (PW) transmission was employed to noninvasively estimate the pressure distribution and fractional flow in the middle cerebral artery (MCA) in vitro. Consequently, the effects of incident sound pressure (peak negative pressures of 86-653 kPa), pulse repetition frequency (PRF), number of pulses, and blood flow rate on the subharmonic pressure relationship were investigated. The radio frequency data were stored and beamformed offline, and the subharmonic amplitude over a 0.4 MHz bandwidth was extracted using a 12-cycle PW at 4 MHz. The optimal incident sound pressure was 217 kPa without skull (sensitivity = 0.09 dB/mmHg; r2 = 0.997) and 410 kPa with skull (median sensitivity = 0.06 dB/mmHg; median r2 = 0.981). The optimal PRF was 500 Hz, as this value affords the highest sensitivity (0.09 dB/mmHg; r2 = 0.976) and temporal resolution. In addition, the blood flow rate exhibited a lesser effect on the subharmonic pressure relationship in our experimental setup. Using the optimized parameters, the blood pressure distribution and fractional flow (FFs) were measured. As such, the FFs value was in high agreement with the value measured using the pressure sensor (FFm). The mean ± standard deviations of the FF difference (FFm - FFs) were 0.03 ± 0.06 without skull and 0.01 ± 0.05 with skull.


Assuntos
Microbolhas , Artéria Cerebral Média , Artéria Cerebral Média/diagnóstico por imagem , Imagens de Fantasmas , Meios de Contraste , Ultrassonografia
14.
Vet Radiol Ultrasound ; 65(1): 10-13, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38047483

RESUMO

A 5-year-old intact male mixed-breed dog presented with a 3-day history of stranguria and dysuria. Results of physical examination, plain radiographs, and ultrasonography were consistent with a traumatic urethral stricture in the prescrotal urethra just under the previous trauma region, resulting in partial obstruction of urine outflow. Contrast-enhanced voiding urosonography (CE-VUS) was performed, and a urethral stricture was confirmed. The dog underwent surgery. A scrotal urethrostomy was performed. After 3 days of hospitalization, the dog was discharged from the Clinic. Based on an extensive literature review, this is the first report using CE-VUS to evaluate urethral pathology in a canine patient.


Assuntos
Doenças do Cão , Estreitamento Uretral , Animais , Cães , Masculino , Meios de Contraste , Doenças do Cão/diagnóstico por imagem , Doenças do Cão/cirurgia , Disuria/veterinária , Radiografia , Ultrassonografia/veterinária , Ultrassonografia/métodos , Uretra/diagnóstico por imagem , Uretra/cirurgia , Estreitamento Uretral/diagnóstico por imagem , Estreitamento Uretral/etiologia , Estreitamento Uretral/cirurgia , Estreitamento Uretral/veterinária , Micção
15.
J Ultrasound Med ; 43(1): 189-200, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37929626

RESUMO

Ultrasound contrast agent (UCA) use is increasing. Recent isolated reports observed a rise in pain-related adverse events with the intravenous administration of the UCA Definity in adults with sickle cell disease. To date, no studies have investigated the incidence of similar adverse events with UCA Lumason or Optison. We describe our experience regarding the safety of Lumason and Optison in children with sickle cell disease and trait who underwent contrast-enhanced ultrasound exams in our department with intravenous, intravesical, and other intracavitary routes. No pain-related or other adverse events were observed in this pediatric population with any route of UCA administration.


Assuntos
Anemia Falciforme , Meios de Contraste , Adulto , Humanos , Criança , Meios de Contraste/efeitos adversos , Ultrassonografia , Infusões Intravenosas , Anemia Falciforme/complicações , Incidência
16.
Acta Pharmaceutica Sinica ; (12): 581-590, 2024.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1016621

RESUMO

In the past few decades, microbubbles were widely used as ultrasound contrast agents in the field of tumor imaging. With the development of research, ultrasound targeted microbubble destruction technology combined with drug-loaded microbubbles can achieve precise drug release and play a therapeutic role. As a micron-scale carrier, microbubbles are difficult to penetrate the endothelial cell space of tumors, and nano-scale drug delivery system—nanobubbles came into being. The structure of the two is similar, but the difference in size highlights the unique advantages of nanobubbles in drug delivery. Based on the classification principle of shell materials, this review summarized micro/nanobubbles used for ultrasound diagnosis or treatment and discussed the possible development directions, providing references for the subsequent development.

17.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 40(6): 1209-1216, 2023 Dec 25.
Artigo em Chinês | MEDLINE | ID: mdl-38151945

RESUMO

Correlation between nonlinear subharmonic scattering of ultrasound contrast agent microbubbles and ambient pressure is expected to be used for local brain tissue pressure monitoring. Although high-frequency ultrasound has achieved high-resolution imaging of intracranial microvessels, the research on high-frequency subharmonic scattering characteristics of microbubbles is insufficient at present, which restricts the research progress of estimating local brain tissue pressure based on high-frequency subharmonic scattering of microbubbles. Therefore, under the excitation of 10 MHz high-frequency ultrasound, the effects of different acoustic pressures and ambient pressures on the high-frequency subharmonic scattering characteristics of three different ultrasound contrast agents including SonoVue, Sonazoid and Huashengxian were investigated in this in vitro study. Results showed that the subharmonic scattering amplitudes of the three microbubbles increased with the increase of ambient pressure at the peak negative acoustic pressures of 696, 766 and 817 kPa, and there was a favorable linear correlation between subharmonic amplitude and ambient pressure. Under the above three acoustic pressures, the highest correlation coefficient of SonoVue was 0.948 ( P = 0.03), the highest sensitivity of pressure measurement was 0.248 dB/mm Hg and the minimum root mean square error (RMSE) was 2.64 mm Hg. Sonazoid's highest correlation coefficient was 0.982 ( P < 0.01), the highest sensitivity of pressure measurement was 0.052 dB/mm Hg and the minimum RMSE was 1.51 mm Hg. The highest correlation coefficient of Huashengxian was 0.969 ( P = 0.02), the highest sensitivity of pressure measurement was 0.098 dB/mm Hg and the minimum RMSE was 2.00 mm Hg. The above in vitro experimental results indicate that by selecting ultrasound contrast agent microbubbles and optimizing acoustic pressure, the correlation between high-frequency subharmonic scattering of microbubbles and ambient pressure can be improved, the sensitivity of pressure measurement can be upgraded, and the measurement error can be reduced to meet the clinical demand for local brain tissue pressure measurement, which provided an important experimental basis for subsequent research in vivo.


Assuntos
Meios de Contraste , Microbolhas , Ultrassonografia/métodos
18.
Echo Res Pract ; 10(1): 23, 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37964335

RESUMO

Ultrasound contrast agents (UCAs) have a well-established role in clinical cardiology. Contrast echocardiography has evolved into a routine technique through the establishment of contrast protocols, an excellent safety profile, and clinical guidelines which highlight the incremental prognostic utility of contrast enhanced echocardiography. This document aims to provide practical guidance on the safe and effective use of contrast; reviews the role of individual staff groups; and training requirements to facilitate its routine use in the echocardiography laboratory.

19.
J Zhejiang Univ Sci B ; 24(11): 985-997, 2023 Nov 15.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-37961801

RESUMO

Sentinel lymph nodes (SLNs) are the first station of lymph nodes that extend from the breast tumor to the axillary lymphatic drainage. The pathological status of these LNs can predict that of the entire axillary lymph node. Therefore, the accurate identification of SLNs is necessary for sentinel lymph node biopsy (SLNB) to replace axillary lymph node dissection (ALND). The quality of life and prognosis of breast cancer patients are related to proper surgical treatment after the precise identification of SLNs. Some of the SLN tracers that have been identified include radioisotope, nano-carbon, indocyanine green (ICG), and methylene blue (MB). However, these tracers have certain limitations, such as pigmentation, radiation dangers, and the requirement for costly detection equipment. Ultrasound contrast agents (UCAs) have good specificity and sensitivity, and thus can compensate for some shortcomings of the mentioned tracers. This technique is also being applied to SLNB in patients with breast cancer, and can even provide an initial judgment on SLN status. Contrast-enhanced ultrasound (CEUS) has the advantages of high distinguishability, simple operation, no radiation harm, low cost, and accurate localization; therefore, it is expected to replace the traditional biopsy methods. In addition, it can significantly enhance the accuracy of SLN localization and shorten the operation time.


Assuntos
Neoplasias da Mama , Linfonodo Sentinela , Humanos , Feminino , Linfonodo Sentinela/diagnóstico por imagem , Linfonodo Sentinela/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Qualidade de Vida , Biópsia de Linfonodo Sentinela/métodos , Ultrassonografia/métodos , Linfonodos/patologia , Linfonodos/cirurgia
20.
Molecules ; 28(22)2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-38005368

RESUMO

There is an urgent need to realize precise clinical ultrasound with ultrasound contrast agents that provide high echo intensity and mechanical index tolerance. Graphene derivatives possess exceptional characteristics, exhibiting great potential in fabricating ideal ultrasound contrast agents. Herein, we reported a facile and green approach to synthesizing reduced graphene oxide with ellagic acid (rGO-EA). To investigate the application of a graphene derivative in ultrasound contrast agents, rGO-EA was dispersed in saline solution and mixed with SonoVue (SV) to fabricate SV@rGO-EA microbubbles. To determine the properties of the product, analyses were performed, including ultraviolet-visible spectroscopy (UV-vis), Fourier-transform infrared spectroscopy (FTIR), Raman spectroscopy, transmission electron microscopy (TEM), thermal gravimetric analysis (TGA), X-ray photoelectron spectrum (XPS), X-ray diffraction analysis (XRD) and zeta potential analysis. Additionally, cell viability measurements and a hemolysis assay were conducted for a biosafety evaluation. SV@rGO-EA microbubbles were scanned at various mechanical index values to obtain the B-mode and contrast-enhanced ultrasound (CEUS) mode images in vitro. SV@rGO-EA microbubbles were administered to SD rats, and their livers and kidneys were imaged in CEUS and B-mode. The absorption of rGO-EA resulted in an enhanced echo intensity and mechanical index tolerance of SV@rGO-EA, surpassing the performance of SV microbubbles both in vitro and in vivo. This work exhibited the application potential of graphene derivatives in the field of ultrasound precision medicine.


Assuntos
Grafite , Ratos , Animais , Grafite/química , Óxidos/química , Ácido Elágico/farmacologia , Meios de Contraste/farmacologia , Microbolhas , Ratos Sprague-Dawley , Análise Espectral Raman