Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Braz. j. otorhinolaryngol. (Impr.) ; Braz. j. otorhinolaryngol. (Impr.);88(2): 220-227, Mar.-Apr. 2022. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1374730

RESUMO

Abstract Introduction: Fine needle aspiration cytology is preferred for thyroid nodules preoperatively, but has disadvantages of false-negative and false-positive results. Objective: To compare the diagnostic performance of grayscale ultrasound, subjective color Doppler ultrasound, and combined features of grayscale ultrasound and subjective color Doppler ultrasound in predicting thyroid carcinoma, using results of the fine needle aspiration cytology as the reference standard. Methods: Data from gray-scale ultrasound images, subjective color Doppler ultrasound images, and the fine needle aspiration cytology of 325 nodules of 250 patients (age ≥ 18 years) were collected and analyzed. Hypo-echogenicity than adjacent strap muscle, micro-lobulated or irregular margins, micro- or mixed calcifications, and taller-than-wide shapes were considered as a suspicious malignant nodule in grayscale ultrasound. Marked vascularity was considered as a suspicious malignant nodule in color Doppler ultrasound. The Bethesda system for classification of thyroid nodules was used for cytopathology. Results: With respect to the results of fine-needle aspiration cytology for detecting suspicious malignant nodules, for grayscale ultrasound, subjective color Doppler ultrasound, and combined gray-scale with subjective color Doppler ultrasound, sensitivities were 0.564, 0.600 and 0.691, respectively and accuracies were 0.926, 0.919 and 0.959, respectively. Suspicious malignant nodules detectability for grayscale ultrasound, subjective color Doppler ultrasound, and combined gray-scale with subjective color Doppler ultrasound were 0.09-0.56 diagnostic confidence, 0.08-0.61 diagnostic confidence, and 0.063-0.7 diagnostic confidence, respectively. Conclusion: The combined gray-scale with subjective color Doppler ultrasound-guided fine-needle aspiration biopsies are recommended for the diagnosis of thyroid carcinoma. Level of Evidence: III.


Resumo Introdução: A citologia da punção aspirativa com agulha fina é preferida para nódulos tireoidianos no pré-operatório, mas apresenta desvantagens de resultados falso-negativos e falso-positivos. Objetivo: Comparar o desempenho diagnóstico da ultrassonografia em escala de cinza, do doppler colorido subjetivo e da combinação dos recursos da ultrassonografia em escala de cinza e do doppler colorido subjetivo na previsão do carcinoma da tireoide com os resultados da citologia da punção aspirativa com agulha fina como padrão de referência. Método: Dados de imagens de ultrassonografia em escala de cinza, imagens subjetivas da ultrassonografia com doppler colorido e citologia da punção aspirativa com agulha fina de 325 nódulos de 250 pacientes (idade ≥ 18 anos) foram coletados e analisados. A hipoecogenicidade da musculatura adjacente, as margens microlobuladas ou irregulares, as microcalcificações ou calcificações mistas e os formatos mais altos do que largos foram considerados como um nódulo maligno suspeito na ultrassonografia em escala de cinza. A vascularização acentuada foi considerada um nódulo maligno suspeito na ultrassonografia com doppler colorido. O sistema Bethesda para classificação de nódulos tireoidianos foi usado para a citopatologia. Resultados: Com relação aos resultados da citologia por punção aspirativa com agulha fina para detecção de nódulos malignos suspeitos, as sensibilidades foram de 0,564, 0,600 e 0,691 para a ultrassonografia em escala de cinza, ultrassonografia com doppler colorido subjetivo e escala de cinza combinada com ultrassonografia com doppler colorido subjetivo, respectivamente, e as acurácias foram 0,926, 0,919 e 0,959, respectivamente. A detectabilidade de nódulos suspeitos malignos para ultrassonografia em escala de cinza, ultrassonografia com doppler colorido subjetivo e escala de cinza combinada com ultrassonografia com doppler colorido subjetivo foram de 0,09-0,56, 0,08-0,61 e 0,063-0,7 de confiança diagnóstica, respectivamente. Conclusões: A ultrassonografia em escala de cinza combinada com o doppler colorido subjetivo e biópsias por punção aspirativa com agulha fina guiadas por ultrassonografia são recomendados para o diagnóstico de carcinoma da tireoide. Nível de evidência: III.


Assuntos
Humanos , Adolescente , Neoplasias da Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/diagnóstico por imagem , Estudos Retrospectivos , Sensibilidade e Especificidade , Biópsia por Agulha Fina
2.
Rev. bras. ginecol. obstet ; Rev. bras. ginecol. obstet;39(9): 464-470, Sept. 2017. tab
Artigo em Inglês | LILACS | ID: biblio-898900

RESUMO

Abstract Objective To describe the blood flow velocities and impedance indices changes in the uterine arteries of leiomyomatous uteri using Doppler sonography. Methods This was a prospective, case-control study conducted on 140 premenopausal women with sonographic diagnosis of uterine leiomyoma and 140 premenopausal controls without leiomyomas. Pelvic sonography was performed to diagnose and characterize the leiomyomas. The hemodynamics of the ascending branches of both main uterine arteries was assessed by Doppler interrogation. Statistical analysis was performed mainly using non-parametric tests. Results The median uterine volume of the subjects was 556 cm3, while that of the controls was 90.5 cm3 (p < 0.001). The mean peak systolic velocity (PSV), end-diastolic velocity (EDV), time-averaged maximum velocity (TAMX), time-averaged mean velocity (Tmean), acceleration time (AT), acceleration index (AI), diastolic/systolic ratio (DSR), diastolic average ratio (DAR), and inverse pulsatility index (PI) were significantly higher in the subjects (94.2 cm/s, 29.7 cm/s, 49.1 cm/s, 25.5 cm/s, 118 ms, 0.8, 0.3, 0.6, and 0.8 respectively) compared with the controls (54.2 cm/s, 7.7 cm/s, 20.0 cm/s, 10.0 cm/s, 92.0 ms, 0.6, 0.1, 0.4, and 0.4 respectively); p < 0.001 for all values. Conversely, the mean PI, resistivity index (RI), systolic/diastolic ratio (SDR) and impedance index (ImI) of the subjects (1.52, 0.70, 3.81, and 3.81 respectively) were significantly lower than those of the controls (2.38, 0.86, 7.23, and 7.24 respectively); p < 0.001 for all values. Conclusion There is a significantly increased perfusion of leiomyomatous uteri that is most likely due to uterine enlargement.


Resumo Objetivo Descrever as velocidades do fluxo sanguíneo e as alterações dos índices de impedância nas artérias uterinas leiomiomatoso utilizando a ultrassonografia Doppler. Métodos Estudo prospectivo, caso-controle, realizado em 140 mulheres pré-menopáusicas com diagnóstico ultrassonográfico de leiomioma uterino e em 140 controles na pré-menopausa sem leiomiomas. A ultrassonografia pélvica foi realizada para diagnosticar e caracterizar os leiomiomas. A hemodinâmica dos ramos ascendentes de ambas as artérias uterinas principais foi avaliada por meio de interrogatório Doppler. A análise estatística foi feita principalmente por meio de testes não paramétricos. Resultados A média do volume uterino dos das pacientes foi de 556 cm3, enquanto a dos controles foi de 90,5 cm3 (p < 0,001). A média de velocidade de pico sistólico (VPS), a velocidade diastólica final (VDF), a velocidade máxima do tempo médio (VMTM), a velocidade média do tempo médio (VMdTM), o tempo de aceleração (TA), o índice de aceleração (IA), a relação diástole/sístole (RDS), a proporção diastólica média (PDM) e o índice de pulsatilidade (IP) inversa foram significativamente maiores em pacientes (94,2 cm/s, 29,7 cm/s, 49,1 cm/s, 25,5 cm/s, 118 ms, 0,8, 0,3, 0,6 e 0,8, respectivamente) do que nos controles (54,2 cm/s, 7,7 cm/s, 20,0 cm/s, 10,0 cm/s, 92,0 ms, 0,6, 0,1, 0,4 e 0,4, respectivamente); p < 0,001 para todos os valores. Por outro lado, o IPmédio, o índice de resistividade (IR), a relação sístole/diástole (RSD) e o índice de impedância (II) nas pacientes (1,52, 0,70, 3,81 e 3,81, respectivamente) foram significativamente mais baixos do que os dos controles (2,38, 0,86, 7,23 e 7,24, respectivamente); p < 0,001 para todos os valores. Conclusão Existe um aumento significativo da perfusão dos úteros leiomiomatosos, que provavelmente se deve ao alargamento uterino.


Assuntos
Humanos , Feminino , Adulto , Neoplasias Uterinas/irrigação sanguínea , Neoplasias Uterinas/diagnóstico por imagem , Fluxometria por Laser-Doppler , Artéria Uterina/diagnóstico por imagem , Leiomioma/irrigação sanguínea , Leiomioma/diagnóstico por imagem , Estudos de Casos e Controles , Estudos Prospectivos , Ultrassonografia Doppler
3.
Acta sci. vet. (Online) ; 44: 01-07, 2016. ilus, tab
Artigo em Português | VETINDEX | ID: vti-722711

RESUMO

Background: Doppler ultrasound is a non-invasive diagnostic imaging technique that allows vascular anatomical and dynamics evaluation. Each artery has flow velocity profiles and different Doppler spectrum. The purpose of this study was to determine if sedation with acepromazine and butorphanol in dogs alters Doppler velocimetric values and diameter from abdominal aorta, celiac, mesenteric cranial, renal, external iliac and femoral arteries of healthy dogs.Materials, Methods & Results: Twenty healthy female dogs, aged 1 to 5 years, with body weight ranging from 10 to 25 kg, were evaluated with Doppler ultrasound in order to obtain: peak systolic velocity, end diastolic velocity, time average medium velocity, time average maximum velocity, resistive index, pulsatility index, and diameter from abdominal aorta, celiac, mesenteric cranial, renal, external iliac and femoral arteries. The same animals were sedated with acepromazine (0.02 mg/kg) and buthorphanol (0.4 mg/kg) and the same parameters were reevaluated. The heart rate was also measured. The study was approved by the Animal Ethics Committee of UFRGS, under the 25552 protocol, and the owners signed an informed consent form. Statistical analysis was performed with pared t test.The heart rate was statistically significant different, 98 ± 20.13 bpm before and 79 ± 17.74 after sedation. The exam was done before and after [...](AU)


Assuntos
Animais , Cães , Acepromazina/análise , Butorfanol/análise , Fluxometria por Laser-Doppler , Fluxometria por Laser-Doppler/veterinária , Artéria Femoral , Aorta Abdominal , Anestésicos Combinados/análise
4.
Acta sci. vet. (Impr.) ; 44: 01-07, 2016. ilus, tab
Artigo em Português | VETINDEX | ID: biblio-1457442

RESUMO

Background: Doppler ultrasound is a non-invasive diagnostic imaging technique that allows vascular anatomical and dynamics evaluation. Each artery has flow velocity profiles and different Doppler spectrum. The purpose of this study was to determine if sedation with acepromazine and butorphanol in dogs alters Doppler velocimetric values and diameter from abdominal aorta, celiac, mesenteric cranial, renal, external iliac and femoral arteries of healthy dogs.Materials, Methods & Results: Twenty healthy female dogs, aged 1 to 5 years, with body weight ranging from 10 to 25 kg, were evaluated with Doppler ultrasound in order to obtain: peak systolic velocity, end diastolic velocity, time average medium velocity, time average maximum velocity, resistive index, pulsatility index, and diameter from abdominal aorta, celiac, mesenteric cranial, renal, external iliac and femoral arteries. The same animals were sedated with acepromazine (0.02 mg/kg) and buthorphanol (0.4 mg/kg) and the same parameters were reevaluated. The heart rate was also measured. The study was approved by the Animal Ethics Committee of UFRGS, under the 25552 protocol, and the owners signed an informed consent form. Statistical analysis was performed with pared t test.The heart rate was statistically significant different, 98 ± 20.13 bpm before and 79 ± 17.74 after sedation. The exam was done before and after [...]


Assuntos
Animais , Cães , Acepromazina/análise , Anestésicos Combinados/análise , Aorta Abdominal , Artéria Femoral , Butorfanol/análise , Fluxometria por Laser-Doppler , Fluxometria por Laser-Doppler/veterinária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA