Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Asian J Transfus Sci ; 18(1): 45-50, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39036694

RESUMO

BACKGROUND: For the management of hemolytic disease of the fetus and newborn (HDFN), it is important to detect unexpected red cell antibody in pregnant women. We assessed the prevalence of unexpected red cell antibodies in consecutive pregnant women attending antenatal clinic (ANC). More importantly, cases with unexpected antibody causing severe anemia were followed-up for intervention (Intra-uterine transfusion {IUT}) and outcome of pregnancy (still-birth/live-healthy). AIMS AND OBJECTIVES: The study was conducted with an objective to find the prevalence of unexpected RBC antibodies in pregnant women, their specificity and to do the follow-up for IUT and outcome of pregnancy (still-birth, live-birth) in antibody positive women. MATERIALS AND METHODS: This was a prospective study from January 2021 to May 2022 at two tertiary care centres. All antenatal samples received by the laboratory were screened for unexpected red cell antibody. Whenever antibody screen was positive, antibody identification was performed. Patients, positive for unexpected antibody and anemia were followed up for any transfusion-based intervention and outcome of pregnancy. RESULTS: A total of 539 consecutive samples were worked up and among these, 10 samples (1.85%) were found to be antibody positive. The antibodies identified were Anti-D (n=6), anti-Leb (n=1), anti-M (n=1), anti-C (n=1) and anti-E (n=1).The prevalence of unexpected antibodies in Rh positive and Rh negative pregnant women was 0.83% and 10.9% respectively. Follow-up was done for all 10 cases with unexpected antibody and anemia was monitored by MCA PSV (middle cerebral artery peak systolic velocity).Two women developed severe anemia thus requiring single intrauterine transfusion (at 26 weeks and 28 weeks respectively) each, for correction of anemia. In both these cases, healthy male child was delivered. At 3-month follow-up both children were alive and healthy. CONCLUSION: The study found prevalence of unexpected RBC antibodies in pregnant women as 1.85%. The study also underlined importance of transfusion-based interventions contributing to successful outcome in couple of cases with severe anemia.

2.
Transfus Apher Sci ; 62(5): 103765, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37532599

RESUMO

INTRODUCTION: The unexpected antibody test is an essential for ensuring the safety of blood transfusions. In infants, different pre-transfusion tests and transfusion strategies are needed due to their immature antigen/antibody system. This study aims to analyze the pattern of unexpected antibodies and their clinical significance in infants. METHODS: A retrospective analysis was conducted on the results of unexpected antibody identification tests performed on infants under one year of age at Asan Medical Center from 1999 to 2022. Patients' unexpected antibody identification test results and clinical information were investigated. The results of unexpected antibody identification and phenotype of each patient's mother were collected. RESULTS: 45 cases of antibody results were studied. 25 cases were found in infants under 4 months of age, and 18 cases (76%) were associated with hemolytic disease of the fetus and newborn (HDFN). The most common unexpected antibody in infants was anti-M (17 cases). There was one case of severe HDFN caused by anti-M. In 10 cases, anti-E and anti-c were found together, and 9 of these cases were associated with HDFN. There were four cases with a history of previous transfusion. CONCLUSIONS: Non-ABO antibodies found in infants showed a different pattern compared to adults. Interpreting unexpected antibody tests in infants, it is important to consider the clinical status of the infant and the test results of the mother, due to possibility of HDFN. To our knowledge, this is the first study to reveal the distribution and clinical significances of unexpected antibodies found in infants in Korea.


Assuntos
Antígenos de Grupos Sanguíneos , Eritroblastose Fetal , Humanos , Lactente , Recém-Nascido , Relevância Clínica , Isoanticorpos , Estudos Retrospectivos
3.
Lab Med ; 54(5): 507-511, 2023 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-36810696

RESUMO

OBJECTIVE: The presence of red blood cell (RBC) irregular antibodies can severely jeopardize mother and child and bring trouble to the treatment of anemia. The aim of this study was to analyze the specificity of RBC irregular antibody in inpatients. METHODS: An analysis was performed on samples from patients with RBC irregular antibodies. Antibody screening positive samples were analyzed. RESULTS: Among the 778 cases of irregular antibody positive samples, 214 were from males and 564 from females. History of blood transfusion accounted for 13.1% of the total. Of the women, 96.8% had a pregnancy. A total of 131 antibodies were identified. The antibodies included 68 Rh systematic antibodies, 6 MNS systematic antibodies, 6 Lewis systematic antibodies, 2 Kidd systematic antibodies, 10 autoantibodies, and 39 antibodies of uncertain specificity. CONCLUSION: Patients with blood transfusion or pregnancy history are prone to produce RBC irregular antibodies.


Assuntos
Transfusão de Sangue , Eritrócitos , Masculino , Criança , Gravidez , Humanos , Feminino , Autoanticorpos , Isoanticorpos
4.
Chinese Journal of Blood Transfusion ; (12): 701-704,705, 2023.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1004769

RESUMO

【Objective】 To observe and analyze the detection results of blood type unexpected antibody and its risk factors in inpatients, so as to provide reference for promoting the safety of clinical blood transfusion. 【Methods】 Clinical data of 22 800 inpatients were collected retrospectively and unexpected antibody screening was performed by microcolumn gel method and saline method. According to the screening results, the inpatients were divided into positive group (n = 62) and negative group (n = 22 738). Clinical data of the two groups were collected and analized by univariate analysis, and specificity identification of unexpected antibody was performed in the positive group. The specific distribution characteristics of antibody were statistically analyzed, and the risk factors of unexpected antibody were analyzed by binary logistic regression. 【Results】 Among the 22 800 inpatients, the yield rate of unexpected antibody was 0.27% (62/22 800), with Rh, MNS, Lewis, Kidd blood group antibody, mixed antibody, autoantibodies and others accounted for 40.32% (25/62), 14.52% (9/62), 6.45%(4/62), 1.61%(1/62), 20.97%(13/62), 6.45%(4/62) and 9.68%(6/62), respectively. Univariate analysis showed that there were significant differences in gender, age, pregnancy history, blood transfusion history, blood transfusion frequency and disease type between the positive group and the negative group by chi-square test (χ2 = 11.142, 6.994, 12.453, 4.762, 5.493, 92.381, all P<0.05), while there was no significant difference in nationality (χ2 = 3.719, P>0.05 ) . Binary logistic regression analysis showed that female, age >60 years old, with history of blood transfusion, number of blood transfusion >3 times, history of pregnancy, solid tumor and blood diseases, severe internal medical diseases were independent risk factors for unexpected antibody(P<0.05) . 【Conclusion】 For patients who need blood transfusion, especially those with the above risk factors, conducting unexpected antibodies screening and identification before transfusion, avoiding corresponding antibodies and selecting antigen-negative blood for cross-matching were suggested to ensure the effectiveness and safety of clinical blood transfusion.

5.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1004745

RESUMO

【Objective】 To analyze the distribution of unexpected antibodies in tumor patients retrospectively and explore the clinical significance. 【Methods】 Unexpected antibody screening was performed on inpatients with blood preparation and blood transfusion in our hospital from January 2004 to December 2022, with 1 176 cases tested positive, and the types of unexpected antibodies and distribution characteristics were statistically analyzed. 【Results】 Unexpected antibodies were screened in 1 176 cases, with the positive rate at 1.05% (1 176/111 483). The unexpected antibodies were mainly anti-E 16.33%(192/1 176), anti-M 7.99% (94/1 176), anti-Mur 5.70% (67/1 176) and anti-Lea 4.76% (56/1 176). Among the 1 176 cases, gastrointestinal tumors accounted for 27.99% (329/1 176), gynecological tumors accounted for 24.84% (292/1 176), respiratory tumors accounted for 16.67% (196/1 176) . 【Conclusion】 The influencing factors of unexpected antibodies in tumor patients were disease type, blood transfusion history and blood type. Therefore, it is necessary for clinical departments to carry out unexpected antibody screening and perform Rh blood type matched transfusion for tumor patients to avoid alloantibody production.

6.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1004704

RESUMO

【Objective】 To analyze the causes of immune hemolytic transfusion reaction in one case, identify related antibodies, and explore transfusion compatibility testing. 【Methods】 ABO/Rh blood group identification, unexpected antibody identification of serum and diffusion fluid, direct antiglobulin test(DAT) and cross matching were conducted by saline method and/or microcolumn gel method. 【Results】 The patient′s blood group was O, and Rh phenotype was identified as DCCee. The DAT was negative, with strong anti-E antibody and weak anti-c antibody detected. Acute hemolytic transfusion reaction occurred in the patient after the last transfusion. 【Conclusion】 Currently, immune hemolytic transfusion reaction in China are mainly caused by Rh blood group system antibodies. The absence of unexpected antibody screening before blood transfusion and the weak anti-c antibody which resulted in missed detection of non compatibility in cross matching led to acute hemolytic transfusion reaction. It is recommended to conduct unexpected antibody screening before blood transfusion, and to collect blood sample for testing as soon as possible to improve the accuracy of DAT when acute hemolytic transfusion reaction is suspected.

7.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1003949

RESUMO

【Objective】 To investigate the clinical characteristics and antibody distribution as well as evaluate the transfusion efficacy in unexpected antibody positive patients. 【Methods】 A total of 12 235 patients from January 1, 2022 to March 31, 2023 who hospitalized in our hospital and applied for blood transfusion were selected, and those with unexpected antibody were included. The clinical data, including gender, age, diagnosis, blood type, history of transfusion and pregnancy were collected for antibody distribution analysis. Patients who received transfusion were grouped according to the DAT results and the components of red blood cells transfused, and the Hb values of each group before and after transfusion were compared. 【Results】 Among12 235 patients, 118 were positive for antibody screening, with a prevalence of 0.96%. The antibodies from Rh system were the most common (27.43%, 48/175), followed by MNS system (8.57%, 15/175) and Lewis system (6.29%, 11/175), mainly anti-E (18.29%, 32/175), anti-M (8.00%, 14/175) and anti-Lea (5.71%, 10/175). In addition, 62 transfused patients were divided into group A with suspended red blood cell transfusion and group B with washed red blood cell transfusion for positive DAT, and group C for negative DAT. Hb values (g/L) pre- and post-transfusion were 59.19±15.67 vs 77.52±15.09 in group A, 56.35±14.08 vs 74.44±15.63 in group B, 56.00±12.06 vs 75.00±4.73 in group C, respectively. The Hb values of post-transfusion for three groups were all higher than those of pre-transfusion (P<0.05). 【Conclusion】 Anti-E from Rh system is the most common antibody in patients with unexpected antibody. Appropriate red blood cells transfusion with Hb increases by an average of 6-7 g/L per 1 U of red blood cells indicating good transfusion efficacy. For positive DAT patients, transfusion of suspended red blood cell is feasible.

8.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1004377

RESUMO

【Objective】 To establish a routine screening method for unexpected antibodies of blood donors, analyze the results of centralized screening for unexpected antibody of blood donors in the blood center, and compare the cost of centralized and decentralized screening modes. 【Methods】 A total of 35 591 blood donors were screened for unexpected antibodies from March 31, 2021 to July 31, 2021, using microcolumn gel method. Unexpected antibody screening reactive samples were further confirmed by the Transfusion Research Institute of Shenzhen Blood Center, and the demographic characteristics were further determined through the analysis of unexpected antibody positive population. The direct cost and indirect cost of centralized and decentralized unexpected antibody screening mode were compared. 【Results】 Forty unexpected antibody positive samples were confirmed in Shenzhen, with the positive rate at 0.11%(40/35 591), among which MNS, Rh and Lewis system accounted for 35% (14/40), 32.5% (13/40) and 17.5% (7/40), respectively. Males and females accounted for 45% (18/40) and 55% (22/40), respectively (P0.05). Unexpected antibody screening in a centralized way saved about 1.16 million yuan per year. 【Conclusion】 It is necessary to carry out unexpected antibody screening for all blood donors, and centralized screening is more economical than decentralized screening.

9.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1004374

RESUMO

【Objective】 To analyze the safety of homotypic transfusion in military donors with negative unexpected antibody. 【Methods】 Blood samples (4 mL/person)of eligible military blood donors from November 2018 to October 2019 in our hospital (also working as forces blood station) were conducted for RBC antigen typing, unexpected antibody screening, direct antiglobulin test and cross-match test using microcolumn gel technology, and the compatibility of homotype blood samples was statistical analyzed. 【Results】 A total of 1 577 samples from eligible military blood donors were collected, including A RhD (+ ), B RhD (+ ), O RhD (+ ) and AB RhD (+ ), accounting for 31.39% (495/1 577), 34.37% (542/1 577), 24.10% (380/1 577) and 10.15% (160/1 577), respectively. Six samples presenting positive unexpected antibodies (0.38%, 6/1 577) were screened out, and a total of 7 141 cross-matching tests were performed on 1 571 unexpected antibody negative samples, including A RhD (+ ) [37.36% (2 668/7 141)], B RhD (+ ) [34.81% (2 486/7 141)], O RhD (+ ) [17.71% (1265/7 141)] and AB RhD (+ ) [10.11% (722/7 141)]. There was only 1 case of incompatible cross-matching presented between other donors and clinical patients, and the direct antiglobulin test was 1+ , therefore suspended red blood cells of the donor were scrapped. 【Conclusion】 There was high compatibility and good security of homotype transfusion of military blood donors with negative unexpected antibody.

10.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1004224

RESUMO

【Objective】 To study the yielding rate and distribution of unexpected antibodies in blood transfusion children with thalassemia in Yunnan province, and to explore the blood transfusion strategies. 【Methods】 From January 2016 to December 2021, 298 children with thalassemia, who received blood transfusion treatment in Kunming, Xishuangbanna, Wenshan, Dehong, Yuxi and Baoshan hospitals across Yunnan Province, were selected. The unexpected antibodies of blood plasma were screened by microcolumn gel card. The samples with positive antibodies were identified for alloantibody specificity. 【Results】 Unexpected antibodies were yielded in 67 out of 298(22.48%) transfused children with thalassemia. The positive rates of unexpected antibodies in boys and girls were 16.55%(24/145) and 28.10%(43/153), respectively. The positive rates of unexpected antibodies in Han, Dai, Zhuang, Yi, Bulang, Jinuo and Miao people were 14.06%(18/128), 30.80%(32/104), 35.71%(10/28), 36.36%(8/22), 50.00%(4/8), 60.00%(3/5)and 66.67%(2/3), respectively, with statistically significant differences between each other. The positive rate of unexpected antibodies in ethnic minorities was higher than that in Han. The positive rates of unexpected antibodies in children who received the first transfusion at birth-one year old, 1~3 years old, 3~6 years old and above 6 years old were 12.50%(3/24), 10.14%(7/69), 24.54%(40/163)and 40.48%(17/42), respectively. The positive rates of unexpected antibodies in children with first transfusion after 3 years old were significantly higher than those before 3 years old. The positive rates of unexpected antibodies in children with one transfusion, 1~3, 3~10, 10~20 and more than 20 transfusions were 4.76%(1/21), 12.07%(7/58), 23.71%(23/97), 28.16%(29/103)and 36.84%(7/19), respectively, with statistically significant differences between each other. The number of blood transfusions was positively correlated with the unexpected antibody yielding. The yielding rate of unexpected antibodies in children with α thalassemia, βthalassemia, δ+ βthalassemia and untyped thalassemia was 7.50%(3/40), 17.62%(34/193), 53.70%(29/54)and 9.09%(1/11), respectively(P<0.05). The yielding rate of unexpected antibodies in transfused children with δ+ βthalassemia was the highest. And 57 unexpected antibodies of Rh blood group system were yielded, 6 anti-M antibodies, 2 anti-N antibodies and 2 undetermined. 【Conclusion】 The positive rate of unexpected antibodies in transfused children with thalassemia in Yunnan province is high. Routine antibody screening should be carried out for transfusion children with thalassemia, and blood units, compatible with ABO, Rh and MNS typing results, should be selected to ensure the safety and effectiveness of clinical blood use.

11.
Saudi J Biol Sci ; 28(8): 4699-4703, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34354457

RESUMO

Unexpected antibodies, also called irregular antibodies, are not known to exist in a person's serum before testing. This research aims to assess the prevalence of unexpected antibodies and their correlation with several clinical conditions. This cross-sectional prospective study, undertaken from June 2019 to June 2020, included ABO, Rh grouping, cross-matching, and antibody screening. Antibody identification was performed only on patients who tested positive in the screening test. From a total of 9764 participants who were screened for unexpected antibodies, 107 (1.1%) tested positive. The Rh blood group system antibodies were the most frequent, particularly anti-D. There was also a significant correlation between the unexpected antibodies and history of transfusion, pregnancy, and autoimmune diseases as P ≤ 0.05. The most prominent unexpected antibodies in the study belong to the Rh system (Anti-D). Moreover, as a result of the strong correlation between the unexpected antibodies as well as the history of transfusion, pregnancy, and autoimmune diseases, the highest safety criteria must be followed during the transfusion of blood to patients with these clinical conditions.

12.
Artigo em Coreano | WPRIM (Pacífico Ocidental) | ID: wpr-713984

RESUMO

BACKGROUND: Among the results of an unexpected antibody screening test using IH-1000, ‘undeterminable’ results can be obtained. Repeated tests not only use reagents and consumables but also cause a turnaround time delay. Therefore, it is important to reduce the ‘undeterminable’ results and to determine the effects. METHODS: From January to early June, 2016, 2,872 cases/259,455 tests (1.11%) of ‘undeterminable’ were detected in the screening test. The factors considered to affect the ‘undeterminable’ were classified into four categories: ① reagent, ② consumables, ③ inspection environment & specimen, and ④ enhancing the equipment management. For data comparison, a chi-square test was conducted (95% confidence interval, 0.05 significant level). RESULTS: The incidence of ‘undeterminable’ cases decreased from 1.11% before management to 0.66% (P < 0.001) after Pool Cells management. The consumption of ‘LISS/Coombs Card’ decreased from 1.07% before management to 0.51% (P < 0.001) after management. By maintaining a clean inspection environment and strengthening sample management, the rate decreased from 1.11% before management to 0.66% (P < 0.001) after management. On the other hand, there was no difference in the incidence of ‘undeterminable’ between before and after IH-1000 management reinforcement. CONCLUSION: Among the factors predicted to affect the decrease in the incidence of ‘undeterminable’, the management of Pool Cells and keeping the inspection environment clean as well as improving sample management contributed the most to the reduced ‘undeterminable’. Improvements in the management of consumables, and removing dust from the inside of the equipment, had a positive impact. A continuous quality improvement theme has been adopted and it is helpful for managing and improving the predicted factors.


Assuntos
Aglutinação , Poeira , Mãos , Incidência , Indicadores e Reagentes , Programas de Rastreamento , Melhoria de Qualidade
13.
Artigo em Coreano | WPRIM (Pacífico Ocidental) | ID: wpr-18195

RESUMO

Delayed hemolytic transfusion reaction is difficult to prevent using an unexpected antibody test performed prior to transfusion, and unlike acute hemolytic transfusion reaction, it occurs a few days after blood transfusion. Hence, determining the reason for delayed hemolytic transfusion reaction may be a tim-consuming task for clinicians Here, we report our experience of two cases of delayed hemolytic transfusion reaction as a result of the unexpected antibody production to Rh blood group antigens after transfusion. The first patient with a history of transfusion during admission was identified as having anti-E and anti-C antibodies according to the antibody identification test at the time of re-admission. The second patient who had chronic blood transfusion due to cancer treatment was found to have anti-C antibody. Both patients received transfusion of Rh antigen-compatible RBC units only after unexpected antibody development. However, like both cases, patients receiving continuous blood transfusion should be considered for a routine Rh phenotype test.


Assuntos
Humanos , Anticorpos , Formação de Anticorpos , Antígenos de Grupos Sanguíneos , Transfusão de Sangue , Fenótipo , Reação Transfusional
14.
Artigo em Coreano | WPRIM (Pacífico Ocidental) | ID: wpr-18194

RESUMO

We report a case of acute hemolytic transfusion reaction due to multiple alloantibodies. A 41-year-old male with multiple histories of transfusion was admitted for jaundice and oliguria after receiving two units of red blood cells in a local clinic. He showed acute renal failure and disseminated intravascular coagulation. Direct Coombs test was negative and antibody screening test showed strong positive results. Anti-E, anti-c, and anti-Jk(b) antibodies were identified in two panels of unexpected antibody assays. Acute hemolytic transfusion was diagnosed, and he was discharged after 1 month of supportive treatment. Unexpected antibody detection tests, including the antiglobulin phase, should be performed to prevent adverse transfusion reactions by unexpected antibodies. Better precision and quality control are necessary when performing pre-transfusion tests.


Assuntos
Adulto , Humanos , Masculino , Injúria Renal Aguda , Anticorpos , Teste de Coombs , Coagulação Intravascular Disseminada , Eritrócitos , Isoanticorpos , Icterícia , Programas de Rastreamento , Oligúria , Controle de Qualidade , Reação Transfusional
15.
Artigo em Coreano | WPRIM (Pacífico Ocidental) | ID: wpr-147856

RESUMO

Anti-f(ce) is a rare unexpected antibody against the ce(f) antigen. The aim of this study is to report a second case of anti-f(ce) identified in a patient. A 66-year-old-male with pancreatic cancer received percutaneous transhepatic biliary drainage. During pretransfusion tests, anti-f(ce) was identified. He had a history of multiple transfusions and was transfused with 2 units of antiglobulin crossmatch compatible RBCs without any adverse reactions. To confirm that the antibody was specific for ce(f) antigen, we crossmatched the patient's serum with RhD-positive red cells of Rh phenotype DcE, DCcEe, DCce, and DCe; all results were negative. Conversely, a crossmatch with RhD-negative red cells of Rh phenotype ce, Cce, and cEe, showed positive results for Rh phenotype ce and cEe red cells. Among the four reports that confirmed anti-e, we discovered the possibility of co-existence of anti-C or misidentification of anti-Ce as anti-e. Therefore, when antibodies against Rh antigens are identified, the possibility of co-existence of antibodies against compound antigens should be considered. Using unexpected antibody identification panel that ce(f) antigen positive red cells are marked is recommended for sensitive detection of anti-f(ce).


Assuntos
Humanos , Anticorpos , Drenagem , Neoplasias Pancreáticas , Fenótipo
16.
Artigo em Coreano | WPRIM (Pacífico Ocidental) | ID: wpr-22648

RESUMO

BACKGROUND: Detection of anti-Kidd antibody is important because of its clinical significance. If detection is difficult due to weak serological reactivity or dosage effect, use of an enzyme method could be helpful. However, despite use of an enzyme method, we still observed weak reactivity of anti-Kidd antibody. METHODS: All identified anti-Kidd antibody cases from Jan 2012 to Aug 2015 in Asan Medical Center were reviewed. Antibody identification test was performed using the column agglutination technique using Bio-Rad ID-DiaPanel with LISS/Coombs card, Bio-Rad ID-DiaPanel-P with NaCl/Enzyme card, and ID-DiaPanel-P with LISS/Coombs card. The test results were compared. RESULTS: Sixty cases of anti-JK(a) or anti-Jk(b) were detected and tested by enzyme method. Among them, 34 (56.6%) cases showed strengthened reactivity using the ID-DiaPanel-P with NaCl/Enzyme card method. However, 26 (43.4%) cases showed weakened reactivity. Of these, 13 cases that could be tested by an additional method using ID-DiaPanel-P with LISS/Coombs card containing anti-IgG and anti-C3d showed successfully strengthened reactivity. CONCLUSION: The reactivity of anti-Kidd antibodies that was not strengthened using ID-DiaPanel-P with NaCl/Enzyme card method could be successfully strengthened by use of the ID-DiaPanel-P with LISS/Coombs card.


Assuntos
Aglutinação , Anticorpos
17.
Artigo em Coreano | WPRIM (Pacífico Ocidental) | ID: wpr-215695

RESUMO

BACKGROUND: Frequency and distribution of unexpected red cell antibodies vary according to study population and method of antibody detection. The frequency and specificities of unexpected red cell antibodies were analyzed and compared in adults and children. METHODS: We analyzed the results of antibody screening and identification tests performed from November of 2008 to June of 2015 at Pusan National University Yangsan Hospital. A commercially available three-cell antigen panel, DiaCell I, II and Dia (DiaMed, Murten, Switzerland) for antibody screening, LISS/Coombs and NaCl/Enzyme card and the ID-Dia Panel (DiaMed, Murten, Switzerland) for antibody identification were used. RESULTS: Among the 91,145 adults, 1,804 (1.97%) had positive results for antibody screening test and 11,457 children, 447 (3.90%) had positive results. In adults, the most frequently detected unexpected antibody was anti-E (103 samples), followed by by anti-E&c (51 samples), anti-Lea (27 samples), and anti-Dia (27 samples). In children, anti-M (7 samples), anti-E&c (5 samples), anti-E (4 samples), and anti-D (4 samples) were most frequently detected. Among 9 pediatric patients with anti-E or anti-E&c, 5 patients were proven as hemolytic disease of the fetus and newborn. CONCLUSION: In this study, the positive rate of unexpected antibody screening in children was higher than in adults. Distribution of unexpected antibody differed between children and adults. It may be related to the frequent cardiac surgery performed in children at our hospital. No studies have been conducted in children. Our research may provide data for the frequency and characteristics of red cell antibodies in children.


Assuntos
Adulto , Criança , Humanos , Recém-Nascido , Anticorpos , Feto , Programas de Rastreamento , Cirurgia Torácica
18.
Artigo em Coreano | WPRIM (Pacífico Ocidental) | ID: wpr-114283

RESUMO

BACKGROUND: The Dia antigen has been found to have a relatively higher incidence among Korean populations. However, the current popular antibody screening panels contain no Dia positive cells. To prevent hemolytic transfusion reaction, screening for unexpected antibody plus screening for Dia positive cells should be performed. In this study, we evaluate the performance of the 3% Surgiscreen Sub-code D (Ortho-Clinical Diagnostics, USA) manufactured as a 3-cell panel including Dia cell versus the ID-DiaCell I-II (DiaMed, Switzerland) as a 2-cell panel plus ID-DiaCell Dia+ (DiaMed, Switzerland) in screening for irregular red blood cell alloantibodies. METHODS: From December 13, 2013 to April 24, 2014, we tested the 3% Surgiscreen by the AutoVue Innova system and the ID-DiaCell in parallel to evaluate reagent sensitivity in detecting irregular antibodies in multi-transfused patients' plasma or serum. Identification of unexpected antibody tests was performed for positive screening results. RESULTS: Antibody-positive rates were 4.2% (79/1885) and 4.6% (87/1885) for antibody screening with the 3% Surgiscreen and the ID-DiaCell, respectively. Among the 1885 samples, 1875 (99.5%) showed concordant results between the 2 methods, while 10 results differed. From the 10 discrepancies, 1 result was positive only on the 3% Surgiscreen. The prevalence of anti-Dia antibody was 10.1% and 9.2% in the 3% Surgiscreen and the ID-DiaCell, respectively. CONCLUSION: The 3% Surgiscreen manufactured as 3-cell showed a high concordance rate ompared to standard methods. The prevalence of anti-Dia showed no difference between the 2 reagents.


Assuntos
Humanos , Anticorpos , Incompatibilidade de Grupos Sanguíneos , Eritrócitos , Incidência , Indicadores e Reagentes , Isoanticorpos , Programas de Rastreamento , Plasma , Prevalência
19.
Blood Res ; 48(3): 217-21, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24086943

RESUMO

BACKGROUND: A combination of the LISS/Coombs and enzyme methods is recommended for identifying unexpected antibodies. However, many laboratories in which tests are to be performed within the limits of medical fees covered by insurance, use only the LISS/Coombs method because the permissible medical fee is low as compared to the price of reagents required for both methods. The NaCl/Enzyme gel is used as a secondary assay when the LISS/Coombs gel test yields inconclusive results. We compared the frequency of unexpected antibody identified by LISS/Coombs gel with that obtained by the conditional combination of LISS/Coombs and NaCl/Enzyme gels. We aimed at establishing evidence-based guidelines for antibody testing. METHODS: From June 2007 to June 2012, antibody screening was performed for 69,986 samples; subsequently, antibodies were identified in samples showing positive screening results. These initial screenings and identifications were performed using the LISS/Coombs gel. We considered the results "inconclusive" when specific antibodies were not identified or reactions were too weak for accurate interpretation. For the inconclusive samples, we subsequently used NaCl/Enzyme gels. RESULTS: The overall detection rate of unexpected antibodies was 1.23%. Among the samples analyzed using NaCl/Enzyme gels, 40.2% showed results different from those obtained using LISS/Coombs gels. Moreover, 41.9% of samples with nonspecific reactions in LISS/Coombs gels showed clinically significant Rh or Kidd antibodies with NaCl/Enzyme gels. CONCLUSION: Considering both patient safety and cost effectiveness, we recommend the use of conditional combination of LISS/Coombs and NaCl/Enzyme gels for antibody detection, especially in laboratories that must perform tests within an established budget.

20.
Blood Research ; : 217-221, 2013.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-172214

RESUMO

BACKGROUND: A combination of the LISS/Coombs and enzyme methods is recommended for identifying unexpected antibodies. However, many laboratories in which tests are to be performed within the limits of medical fees covered by insurance, use only the LISS/Coombs method because the permissible medical fee is low as compared to the price of reagents required for both methods. The NaCl/Enzyme gel is used as a secondary assay when the LISS/Coombs gel test yields inconclusive results. We compared the frequency of unexpected antibody identified by LISS/Coombs gel with that obtained by the conditional combination of LISS/Coombs and NaCl/Enzyme gels. We aimed at establishing evidence-based guidelines for antibody testing. METHODS: From June 2007 to June 2012, antibody screening was performed for 69,986 samples; subsequently, antibodies were identified in samples showing positive screening results. These initial screenings and identifications were performed using the LISS/Coombs gel. We considered the results "inconclusive" when specific antibodies were not identified or reactions were too weak for accurate interpretation. For the inconclusive samples, we subsequently used NaCl/Enzyme gels. RESULTS: The overall detection rate of unexpected antibodies was 1.23%. Among the samples analyzed using NaCl/Enzyme gels, 40.2% showed results different from those obtained using LISS/Coombs gels. Moreover, 41.9% of samples with nonspecific reactions in LISS/Coombs gels showed clinically significant Rh or Kidd antibodies with NaCl/Enzyme gels. CONCLUSION: Considering both patient safety and cost effectiveness, we recommend the use of conditional combination of LISS/Coombs and NaCl/Enzyme gels for antibody detection, especially in laboratories that must perform tests within an established budget.


Assuntos
Anticorpos , Orçamentos , Análise Custo-Benefício , Honorários Médicos , Géis , Indicadores e Reagentes , Seguro , Programas de Rastreamento , Segurança do Paciente , Atenção Terciária à Saúde
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...