Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Artigo em Coreano | WPRIM (Pacífico Ocidental) | ID: wpr-10375

RESUMO

Three external quality assesment trials which composed of 16 control materials(12 chemical materials and four sets of microscopic photograph of urinary sediment) for interlaboratory quality control assesment in urinalysis were performed with 796, 823, and 841 participants, in each, in the year of 2009. The response rate were 97.1% (796/820), 95.5% (823/862) and 97.1% (841/866), in the first, the second and the third trials, in each. The test items include pH, glucose, protein, ketone, bilirubin, blood, urobilinogen, nitrite, leukocyte estrase, specific gravity and four microscopic photographs of urinary sediment. The survey results are summarized as follows: 1. The chemical quality control test in urinalysis revealed generally good concordance. 2. The percentage of using urinalysis analyzer was slightly decreased as 82.3% and the distribution of using reagent strip was similar to the previous year. 3. The percentage of response rate of microscopic photographs of urinary sediment was 83.5% (702/841) and the percentage of good performance of these tests ware 83.6% to 99.1%.


Assuntos
Bilirrubina , Equidae , Glucose , Concentração de Íons de Hidrogênio , Coreia (Geográfico) , Leucócitos , Controle de Qualidade , Fitas Reagentes , Gravidade Específica , Urinálise , Urobilinogênio
2.
Artigo em Coreano | WPRIM (Pacífico Ocidental) | ID: wpr-130603

RESUMO

Three external quality assesment trials which composed of 16 control materials (12 chemical materials and four microscopic photographs of urinary sediment) for interlaboratory quality control assesment in urinalysis were performed with 638, 645, and 662 participants, in each, in the year of 2007. The response rate were 95.5% (638/668), 96.7% (645/667) and 97.1% (662/682), in the first, the second and the third trials, in each. The test items include pH, glucose, protein, ketone, bilirubin, blood, urobilinogen, nitrite, leukocyte esterase, specific gravity and four microscopic photographs of body fluid and urinary sediment. The survey results are summarized as follows: 1. The chemical quality control test in urinalysis revealed generally good concordance. 2. The percentage of using urinalysis analyzer was slightly increased as 87.5% and the distribution of using reagent strip was similar to the previous year. 3. The percentage of response rate of microscopic photographs of urinary sediment was 80.7% (536/662) and the percentage of good performance of these tests was 60.6% to 99.1%.


Assuntos
Bilirrubina , Líquidos Corporais , Hidrolases de Éster Carboxílico , Equidae , Glucose , Concentração de Íons de Hidrogênio , Coreia (Geográfico) , Leucócitos , Controle de Qualidade , Fitas Reagentes , Gravidade Específica , Urinálise , Urobilinogênio
3.
Artigo em Coreano | WPRIM (Pacífico Ocidental) | ID: wpr-130610

RESUMO

Three external quality assesment trials which composed of 16 control materials (12 chemical materials and four microscopic photographs of urinary sediment) for interlaboratory quality control assesment in urinalysis were performed with 638, 645, and 662 participants, in each, in the year of 2007. The response rate were 95.5% (638/668), 96.7% (645/667) and 97.1% (662/682), in the first, the second and the third trials, in each. The test items include pH, glucose, protein, ketone, bilirubin, blood, urobilinogen, nitrite, leukocyte esterase, specific gravity and four microscopic photographs of body fluid and urinary sediment. The survey results are summarized as follows: 1. The chemical quality control test in urinalysis revealed generally good concordance. 2. The percentage of using urinalysis analyzer was slightly increased as 87.5% and the distribution of using reagent strip was similar to the previous year. 3. The percentage of response rate of microscopic photographs of urinary sediment was 80.7% (536/662) and the percentage of good performance of these tests was 60.6% to 99.1%.


Assuntos
Bilirrubina , Líquidos Corporais , Hidrolases de Éster Carboxílico , Equidae , Glucose , Concentração de Íons de Hidrogênio , Coreia (Geográfico) , Leucócitos , Controle de Qualidade , Fitas Reagentes , Gravidade Específica , Urinálise , Urobilinogênio
4.
Artigo em Coreano | WPRIM (Pacífico Ocidental) | ID: wpr-98183

RESUMO

Three external quality assesment trials which composed of 16 control materials (12 chemical materials and four microscopic photographs of urinary sediment) for interlaboratory quality control assesment in urinalysis were performed with 451, 452, and 476 participants, in each, in the year of 2005. The response rate were 95.6% (451/472), 91.9% (452/492) and 95.6% (476/498), in the first , the second and the third trials, in each. The test items include pH, glucose, protein, ketone, bilirubin, blood, urobilinogen, nitrite, leukocyte estrase, specific gravity and four microscopic photographs of urinary sediment. The survey results are summarized as follows: 1. The chemical quality control test in urinalysis revealed generally good concordance. 2. The percentage of using urinalysis analyzer was slightly increased as 91.2% and the distribution of using reagent strip was similar to the previous year. 3. The percentage of response rate of microscopic photographs of urinary sediment was 76.5%(387/498) and the percentage of good performance of these tests ware 63.6% to 86.5%.


Assuntos
Bilirrubina , Equidae , Glucose , Concentração de Íons de Hidrogênio , Coreia (Geográfico) , Leucócitos , Controle de Qualidade , Fitas Reagentes , Gravidade Específica , Urinálise , Urobilinogênio
5.
Artigo em Coreano | WPRIM (Pacífico Ocidental) | ID: wpr-68695

RESUMO

Three external quality assesment trials which composed of 16 control materials(12 chemical materials and four microscopic photographs of urinary sediment) for interlaboratory quality control assesment in urinalysis were performed with 446, participants, in each, in the year of 2004. The response rate were 93.4% (422/452), 91.7% (411/448) and 91.7% (410/447), in the first , the second and the third trials, in each. The test items include pH, glucose, protein, ketone, bilirubin, blood, urobilinogen, nitrite, leukocyte estrase, specific gravity and four microscopic photographs of urinary sediment. The survey results are summarized as follows: 1.The chemical quality control test in urinalysis revealed generally good concordance. 2.The percentage of using urinalysis analyzer was slightly increased as 87.9% and the distribution of using reagent strip was similar to the previous year. 3.The percentage of response rate of microscopic photographs of urinary sediment was 80.7% and the percentage of good performance of these tests ware 85.8% to 95.8%.


Assuntos
Bilirrubina , Equidae , Glucose , Concentração de Íons de Hidrogênio , Coreia (Geográfico) , Leucócitos , Controle de Qualidade , Fitas Reagentes , Gravidade Específica , Urinálise , Urobilinogênio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...