Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
1.
Int J Cardiol ; 413: 132343, 2024 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-38977227

RESUMO

BACKGROUND: Vessel injury is a common complication during balloon pulmonary angioplasty (BPA). For persistent hemoptysis, gelatin sponge embolization (GSE) is considered, but its impact on subsequent perfusion in embolized vessels remains unknown. This study explores the feasibility of revascularization in vessels post-GSE. METHODS: We included 64 vessels from 50 patients with chronic thromboembolic pulmonary hypertension who experienced hemoptysis during BPA in 2012-2023. Twenty-four vessels were treated conservatively (conservative group), while 40 were treated with GSE for persistent hemoptysis or desaturation despite conservative treatment (GSE group). We assessed hemoptysis-related parameters, perfusion of injured vessels pre- and post-treatment, and hemodynamic parameters through multiple BPA sessions. RESULTS: Hemoptysis resolved immediately after the procedure in 67% of patients, including 70% of those in the GSE group, and all cases resolved by the next day. Of 37 embolized vessels, 41% showed spontaneous perfusion improvement in subsequent sessions. BPA was reperformed in 22 embolized vessels, with 86% showing further improvement, resulting in 70% of all embolized vessels finally showing improvement in perfusion. In both groups, clinical and hemodynamic parameters significantly improved after BPA. CONCLUSIONS: Perfusion of embolized vessels improved after GSE, suggesting that GSE is safe for the treatment of severe persistent hemoptysis after conservative treatment.

2.
BMC Surg ; 24(1): 194, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38907190

RESUMO

BACKGROUND: posterior pedicle screw fixation is common method, one of the most severe complications is iatrogenic vascular damage, no report investigated association of different introversion angles (INTAs) and length of pedicle screw. The aims were to investigate the optimal introversion angle and length of pedicle screw for improving the safety of the operation, and to analyze the differences of vascular damage types at L1-S1. METHODS: Lumbar CT imaging data from110 patients were analyzed by DICOM software, and all parameters were measured by new Cartesian coordinate system, INTAs (L1-L5:5°,10°,15°,S1: 0°, 5°,10°,15°), DO-AVC (the distance between the origin (O) with anterior vertebral cortex (AVC)), DAVC-PGVs (the distance between AVC and the prevertebral great vessels (PGVs)), DO-PGVs (the distance between the O and PGVs). At different INTAs, DAVC-PGVs were divided into four grades: Grade III: DAVC-PGVs ≤ 3 mm, Grade II: 3 mm < DAVC-PGVs ≤ 5 mm, Grade I: DAVC-PGVs > 5 mm, and N: the not touching PGVs. RESULTS: The optimal INTA was 5° at L1-L3, the left was 5° and the right was 15° at L4, and screw length was less than 50 mm at L1-L4. At L5, the left optimal INTA was 5° and the right was 10°, and screw length was less than 45 mm. The optimal INTA was 15° at S1, and screw length was less than 50 mm. However, screw length was less than 40 mm when the INTA was 0° or 5° at S1. CONCLUSIONS: At L5-S1, the risk of vascular injury is the highest. INTA and length of the pedicle screw in lumbar operation are closely related. 3 mm interval of screw length may be more preferable to reduce vascular damage.


Assuntos
Vértebras Lombares , Parafusos Pediculares , Fusão Vertebral , Lesões do Sistema Vascular , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Vértebras Lombares/cirurgia , Vértebras Lombares/diagnóstico por imagem , Idoso , Lesões do Sistema Vascular/prevenção & controle , Lesões do Sistema Vascular/etiologia , Adulto , Fusão Vertebral/métodos , Fusão Vertebral/instrumentação , Tomografia Computadorizada por Raios X , Sacro/cirurgia , Sacro/diagnóstico por imagem , Sacro/lesões , Estudos Retrospectivos
3.
Eur J Case Rep Intern Med ; 11(4): 004362, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38584897

RESUMO

Introduction: Rectus sheath haematoma (RSH) has become increasingly common but is often underdiagnosed. Prompt diagnosis will avoid unnecessary investigations and procedures, resulting in early treatment and a better outcome. Case description: We described a case of a spontaneous RSH with intraperitoneal extension and formation of a vesico-haematoma fistula, which was initially misdiagnosed as a urinary tract infection. The diagnosis was made ten days after admission, when a CT scan showed an over-16 cm RSH with intraperitoneal extension, bladder perforation and a vesico-haematoma fistula. The patient was managed conservatively. Discussion: RSH accounts for less than 2% of acute abdomen cases and is often unrecognised. Its presentation can mimic other intra-abdominal pathologies, and the diagnosis is often delayed or missed. Complications can arise from an RSH although it is generally viewed as a self-limiting condition. Conclusion: RSH has become increasingly common, and we would like to highlight the need to include abdominal wall pathologies in the initial differential diagnoses of acute abdomen to avoid delay in diagnosis. LEARNING POINTS: Rectus sheath haematoma has become increasingly common due to the use of anticoagulants.The presentation can be non-specific and mimic other intra-abdominal pathologies. Misdiagnosis or delayed diagnosis can result in complications and unnecessary invasive procedures.Abdominal wall pathologies including rectus sheath haematomas should be included in initial differentials of acute abdomen.

4.
Polymers (Basel) ; 16(6)2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38543468

RESUMO

A traumatic hemorrhage is fatal due to the great loss of blood in a short period of time; however, there are a few biomaterials that can stop the bleeding quickly due to the limited water absorption speed. Here, a highly absorbent polymer (HPA), polyacrylate, was prepared as it has the best structure-effectiveness relationship. Within a very short period of time (2 min), HPA continually absorbed water until it swelled up to its 600 times its weight; more importantly, the porous structure comprised the swollen dressing. This instantaneous swelling immediately led to rapid hemostasis in irregular wounds. We optimized the HPA preparation process to obtain a rapidly water-absorbent polymer (i.e., HPA-5). HPA-5 showed favorable adhesion and biocompatibility in vitro. A rat femoral arteriovenous complete shear model and a tail arteriovenous injury model were established. HPA exhibited excellent hemostatic capability with little blood loss and short hemostatic time compared with CeloxTM in both of the models. The hemostatic mechanisms of HPA consist of fast clotting by aggregating blood cells, activating platelets, and accelerating the coagulation pathway via water absorption and electrostatic interaction. HPA is a promising highly water-absorbent hemostatic dressing for rapid and extensive blood clotting after vessel injury.

5.
J Arthroplasty ; 39(4): 1088-1092, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37918488

RESUMO

BACKGROUND: Iatrogenic vascular injury during total hip arthroplasty (THA) is rare, reported at rates of 0.05 to 0.3%, but a potentially limb-threatening and life-threatening complication. We aimed to describe safe and danger zones for the superior gluteal vessel bundle (SGV bundle) with reference to different THA approaches. METHODS: There were 27 formalin-fixed cadavers with 49 hemipelves dissected. The course and distribution of the SGV bundle were investigated with the help of anatomical landmarks like the greater trochanter, the iliac tubercle (IT), and the ischial tuberosity. RESULTS: We found and exposed the SGV bundle in all 49 specimens with no sex-specific differences. No SGV bundle was encountered up to 28 mm from the greater trochanter and up to 16 mm below the IT. The zone with the highest probability of finding the vessels was 25 to 65 mm below the IT in 39 (80%) cases - defining a danger zone (in relation to the skin incision) in the proximal fourth for the direct anterior approach, in the proximal half for the antero-lateral approach, in the proximal fifth for the direct lateral approach, and almost no danger zone for the posterior approach. CONCLUSIONS: Special care in proximal instrument placement should be taken during THA. When extending one of the surgical approaches, manipulations in the proximal, cranial surgical window should be performed with the utmost care to avoid SGV bundle injury.


Assuntos
Artroplastia de Quadril , Lesões do Sistema Vascular , Humanos , Nádegas/cirurgia , Cadáver , Fêmur , Lesões do Sistema Vascular/etiologia , Lesões do Sistema Vascular/prevenção & controle
6.
Surg Neurol Int ; 14: 374, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37941627

RESUMO

Background: Anterior lumbar interbody fusion (ALIF) offers direct midline access to the lumbar intervertebral discs utilizing an anterior retroperitoneal approach. Here, a 33-year-old female undergoing ALIF developed an acute intraoperative left iliac artery thrombus and underwent immediate successful embolectomy. Case Description: A 33-year-old female was undergoing routine L5-S1 ALIF when an acute intraoperative left iliac vein injury occurred, requiring immediate repair by a vascular surgeon. Her left foot pulse oximeter showed a decreased reading, and her Doppler ultrasound confirmed reduced flow in the distal external iliac artery due to a thrombus. She required an immediate left iliac artery embolectomy, and flow was immediately restored. Postoperatively, she recovered well, and 3 months postoperatively, she remained neurologically intact without any further complications. Conclusion: Using pulse oximeters in patients undergoing ALIF surgery can aid in facilitating the diagnosis and treatment of acute artery thrombi. When such vascular injuries arise, having immediate access to experienced vascular surgeons is critical to obtain expeditious treatment and optimize patient outcomes.

7.
Catheter Cardiovasc Interv ; 102(4): 585-593, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37560823

RESUMO

BACKGROUND: Donor vessel injury is a potentially life-threatening complication of chronic total occlusion (CTO) percutaneous coronary intervention (PCI). AIMS: Our goal was to examine the incidence, mechanisms, treatment, and outcomes of patients with donor vessel injury in a large multicenter CTO PCI registry. METHODS: We analyzed the baseline clinical and angiographic characteristics, and procedural outcomes of 12,349 CTO PCIs performed between 2012 and 2022 at 44 centers. RESULTS: The incidence of donor vessel injury was 0.35% (n = 43). The baseline clinical characteristics of patients with and without donor vessel injury were similar. Cases complicated by donor vessel injury were more complex with higher Japanese CTO score (2.9 ± 1.1 vs. 2.4 ± 1.3; p = 0.004) and lower procedural success rate (69.8% vs. 85.2%; p = 0.004). The retrograde approach was used more commonly in donor vessel injury cases (68.9% vs. 30.9%; p < 0.001). Most (53.5%) donor vessel injuries were guide catheter-induced, whereas 20.9% were due to donor vessel thrombosis. Of the 43 patients with donor vessel injury, 36 (83.7%) were treated with stenting and seven (16.3%) received a left ventricular assist device. The incidence of major adverse cardiovascular events (MACEs) was significantly higher in cases with donor vessel injury (23.3% vs. 2.0%; p < 0.001). Of the 43 patients with donor vessel injury, five patients (11.6%) experienced acute myocardial infarction and four patients (9.3%) died. CONCLUSIONS: Donor vessel injury, occurred in 0.35% of CTO PCIs performed by experienced operators, was mainly due to guide catheter-induced dissection or thrombosis and was associated with lower procedural success and higher MACE.

8.
Spine Surg Relat Res ; 7(3): 249-256, 2023 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-37309500

RESUMO

Introduction: Lateral lumbar interbody fusion (LLIF) has been introduced in Japan in 2013. Despite the effectiveness of this procedure, several considerable complications have been reported. This study reported the results of a nationwide survey performed by the Japanese Society for Spine Surgery and Related Research (JSSR) on the complications associated with LLIF performed in Japan. Methods: JSSR members conducted a web-based survey following LLIF between 2015 and 2020. Any complications meeting the following criteria were included: (1) major vessel, (2) urinary tract, (3) renal, (4) visceral organ, (5) lung, (6) vertebral, (7) nerve, and (8) anterior longitudinal ligament injury; (9) weakness of psoas; (10) motor and (11) sensory deficit; (12) surgical site infection; and (13) other complications. The complications were analyzed in all LLIF patients, and the differences in incidence and type of complications between the transpsoas (TP) and prepsoas (PP) approaches were compared. Results: Among the 13,245 LLIF patients (TP 6,198 patients [47%] and PP 7,047 patients [53%]), 389 complications occurred in 366 (2.76%) patients. The most common complication was sensory deficit (0.5%), followed by motor deficit (0.43%) and weakness of psoas muscle (0.22%). Among the patient cohort, 100 patients (0.74%) required revision surgery during the survey period. Almost half of the complications developed in patients with spinal deformity (183 patients [47.0%]). Four patients (0.03%) died from complications. Statistically more frequent complications occurred in the TP approach than in the PP approach (TP vs. PP, 220 patients [3.55%] vs. 169 patients [2.40%]; p<0.001). Conclusions: The overall complication rate was 2.76%, and 0.74% of the patients required revision surgery because of complications. Four patients died from complications. LLIF may be beneficial for degenerative lumbar conditions with acceptable complications; however, the indication for spinal deformity should be carefully determined by the experience of the surgeon and the extent of the deformity.

9.
J Clin Neurosci ; 114: 70-76, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37321020

RESUMO

OBJECTIVE: Rapid and efficacious haemostasis is paramount in neurosurgery. Assessing the efficacy and short- and long-term safety of haemostatic agents utilised within cerebral tissue is essential. This pilot study investigates the haemostatic efficacy and long-term safety of a novel beta-chitin patch against traditionally used agents, bipolar and Floseal, within cerebral tissue. METHODS: Eighteen Merino sheep underwent standardised distal cortical vessel injury via temporal craniotomy. Sheep were randomised to receive 2 mls Floseal, 2 cm novel beta-chitin patch, or bipolar cautery to manage bleeding. All sheep underwent cerebral magnetic resonance imaging (MRI) at three months, before euthanasia and brain harvesting for histological assessment. RESULTS: Beta-chitin demonstrated a trend towards a faster mean time to haemostasis (TTH) compared to Floseal (223.3 ± 199 s v. 259.8 ± 186.4 s), albeit non-significant (p = 0.234). Radiologically, cerebrocortical necrosis (p = 0.842) and oedema (p = 0.368) were noted slightly more frequently in the beta-chitin group. Histologically, severe fibrotic (p = 0.017) and granulomatous changes at the craniotomy sites were only present in the beta-chitin group (p = 0.002). Neuronal degeneration was seen in all with Floseal, but beta-chitin showed a trend towards more severe reaction when present. Bipolar use predominantly showed an inflammatory cortical reaction with substantial microvascular proliferation, and Floseal showed worse severity and depth of subpial oedema, however no statistical significance was reached. CONCLUSION: All haemostats controlled bleeding, with beta-chitin demonstrating a non-inferior TTH compared to Floseal. However, it resulted in intense granulomatous and fibrotic changes, including degenerative neuronal reactions. More extensive studies are needed to assess these trends, to make further clinical inferences.


Assuntos
Hemostáticos , Ovinos , Animais , Hemostáticos/farmacologia , Projetos Piloto , Esponja de Gelatina Absorvível , Hemostasia , Hemostasia Cirúrgica/métodos , Quitina/farmacologia , Quitina/uso terapêutico
10.
Cardiovasc Revasc Med ; 53S: S292-S295, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36737384

RESUMO

Donor vessel injury is a well-known complication of chronic total occlusion (CTO) percutaneous coronary intervention (PCI). Due to significant amount of myocardium at risk, donor vessel injury may lead to rapid hemodynamic collapse. In this setting, prompt restoration of blood flow into the donor artery is of paramount importance. Advancement of a safety coronary workhorse guidewire in the donor vessel prior to attempting CTO PCI is a simple maneuver that provides access to the donor artery for rapid coronary intervention and restoration of blood flow, in the event of donor vessel injury. We describe two cases of CTO PCI that illustrate the value of the safety coronary guidewire.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/etiologia , Oclusão Coronária/terapia , Resultado do Tratamento , Coração , Doença Crônica , Angiografia Coronária
11.
J Surg Case Rep ; 2023(2): rjac576, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36755932

RESUMO

Iatrogenic arteriovenous fistula (IAVF) is an unusual and potentially fatal complication of lumbar spinal surgery. A 62-year-old patient presented with a history of dyspnea, left lower limb edema and coughing. A physical exam showed bilateral basal rales in the lungs, abdominal bruit and bilateral lower limb pitting edema. A computed tomography angiograph revealed an arteriovenous communication between the right internal iliac artery and the left common iliac vein. The patient was diagnosed with an IAVF, which developed post-lumbar disc surgery. The patient underwent a successful endovascular treatment by using covered stent at the common iliac artery with embolism of lumbar artery. The patient's symptoms were relieved 2 months after surgery.

12.
J Pediatr Surg ; 57(7): 1358-1362, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34955290

RESUMO

BACKGROUND: Cardiac injuries are rare in pediatric trauma patients and data regarding this type of injury is limited. There is even less data on traumatic great vessel injuries. This study sought to examine and summarize our recent experience at two pediatric trauma centers, which serve a major metropolitan area and large geographic region. METHODS: This is a retrospective review of pediatric (<18 years) patients who sustained cardiac or great vessel injuries and were managed at a Level 1 or Level 2 pediatric trauma center between January 1, 2010 and June 30, 2020. Demographic and clinical characteristics were compared using two-sample t-tests, Wilcoxon Rank-Sum tests, Fisher's exact tests and chi-squared tests for continuous, non-normally distributed continuous, and categorical variables, respectively. RESULTS: A total of 53 patients sustained cardiac and/or great vessel injuries. Of these, 37 (70%) sustained cardiac, 9 (17%) sustained great vessel, and 7 (13%) sustained both types of injuries. The median age was 14.9 years and 74% (n = 39) were male. The median injury severity score (ISS) was 36.0 and the injury mechanism was blunt in 31 (58%) patients. The most common cardiac and great vessel injury locations were left ventricle (n = 9) and thoracic aorta (n = 11), respectively. The overall mortality rate was 53% (n = 28). Mortality was highest among those who sustained great vessel injuries (89%). CONCLUSIONS: There is substantial heterogeneity in cardiac and great vessel injuries. Regardless, they are highly morbid and lethal, despite aggressive surgical and catheter-based interventions.


Assuntos
Traumatismos Cardíacos , Lesões do Sistema Vascular , Ferimentos não Penetrantes , Adolescente , Aorta Torácica/lesões , Criança , Feminino , Traumatismos Cardíacos/epidemiologia , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/cirurgia , Humanos , Escala de Gravidade do Ferimento , Masculino , Estudos Retrospectivos , Centros de Traumatologia , Lesões do Sistema Vascular/epidemiologia , Lesões do Sistema Vascular/cirurgia , Ferimentos não Penetrantes/epidemiologia , Ferimentos não Penetrantes/cirurgia
13.
Vasc Endovascular Surg ; 56(1): 40-48, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34533371

RESUMO

Traumatic injuries to the mesenteric vessels are rare and often lethal. Visceral vessels, such as the superior mesenteric artery (SMA) and vein (SMV), supply blood to the small and large bowel by a rich system of collaterals. Because fewer than 100 such injuries have been described in the literature, they pose challenges in both diagnosis and management and can unfortunately result in high mortality rates. Prompt diagnosis, surgical intervention, and resuscitation can lead to improved outcomes. Here, we review the literature surrounding traumatic injuries of the SMA/SMV and discuss management strategies.


Assuntos
Artéria Mesentérica Superior , Lesões do Sistema Vascular , Abdome , Humanos , Artéria Mesentérica Superior/diagnóstico por imagem , Artéria Mesentérica Superior/cirurgia , Veias Mesentéricas/diagnóstico por imagem , Veias Mesentéricas/cirurgia , Resultado do Tratamento , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/etiologia , Lesões do Sistema Vascular/cirurgia
14.
Surg Case Rep ; 7(1): 177, 2021 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-34347166

RESUMO

BACKGROUND: Open complete transection of the femoral artery and vein following blunt trauma is extremely rare. Furthermore, even if the patient has been successfully resuscitated, it is sometimes difficult in most patients to preserve the injured limb, especially after damage control resuscitation. We report a case of open complete transection of the femoral artery and vein secondary to high-energy blunt trauma and a successful limb preservation treatment strategy. CASE PRESENTATION: A 57-year-old Asian man was transferred to hospital after having fallen from the 15th floor of a condominium. The patient was in cardiac arrest at the scene, but was successfully resuscitated by emergency medical services staff. On arrival, the patient's hemodynamics were completely collapsed with active external bleeding from the thigh, so we immediately started resuscitation including activation of massive transfusion protocol and temporarily ligated the transected proximal superficial femoral artery, deep femoral artery just distal after branching lateral femoral circumflex artery and the superficial femoral vein. Following radiological findings showing a potential pelvic fracture with active bleeding, we also performed retroperitoneal packing in the resuscitation room and moved the patient to the angiography room for transcatheter arterial embolization. The patient's consciousness was preserved and perfusion of the injured limb was barely maintained after his hemodynamics were adequately stabilized. As we detected weak perfusion of the lower limb via a potential collateral flow from the lateral femoral circumflex artery branches from deep femoral artery by pulse doppler of the dorsal pedis artery, we decided to reconstruct superficial femoral artery and vein at 24 h after injury using great saphenous vein bypass grafts. The patient was transferred to a rehabilitation hospital with good neurological and limb outcome after hospitalization for 52 days. CONCLUSION: We successfully preserved the patient's lower limb after cardiac arrest and complete transection of the femoral artery and vein and achieved a good neurological outcome. Even if a femoral artery needs to be ligated temporarily, careful observation and assessment should be performed so as not to lose the chance to salvage the limb even during damage control resuscitation.

15.
Surg Neurol Int ; 12: 109, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33880214

RESUMO

BACKGROUND: Carotid endarterectomy (CEA) has been the standard preventive procedure for cerebral infarction due to cervical internal carotid artery stenosis, and internal shunt insertion during CEA is widely accepted. However, troubleshooting knowledge is essential because potentially life-threatening complications can occur. Herein, we report a case of cervical internal carotid artery injury caused by the insertion of a shunt device during CEA. CASE DESCRIPTION: A 78-year-old man with a history of hypertension, diabetes, and hyperuricemia developed temporary left hemiplegia. A former physician had diagnosed the patient with a transient cerebral ischemic attack. The patient's medical history was significant for the right internal carotid artery stenosis, which was severe due to a vulnerable plaque. We performed CEA to remove the plaque; however, there was active bleeding in the distal carotid artery of the cervical region after we removed the shunt tube. Hemostasis was achieved through compression using a cotton piece. Intraoperative digital subtraction angiography (DSA) revealed severe stenosis at the internal carotid artery distal to the injury site due to hematoma compression. The patient underwent urgent carotid artery stenting and had two carotid artery stents superimposed on the injury site. On DSA, extravascular pooling of contrast media decreased on postoperative day (POD) 1 and then disappeared on POD 14. The patient was discharged home without sequela on POD 21. CONCLUSION: In the case of cervical internal carotid artery injury during CEA, hemostasis can be achieved by superimposing a carotid artery stent on the injury site, which is considered an acceptable troubleshooting technique.

16.
Trauma Case Rep ; 31: 100380, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33385056

RESUMO

Percutaneous iliosacral screw placement has become the technique of choice for treating injuries to the posterior pelvis. However, the technique requires an understanding of the anatomy surrounding the bone corridors to avoid complications and detect them early if they occur. We present the clinical case of a patient with a U-shaped fracture of the sacrum that evolves with gluteal pain and left foot equine paresis after percutaneous fixation with iliosacral screws. Angio-CT of the pelvis shows active arterial bleeding from the superior gluteal artery associated to extensive hematoma in the thickness of the gluteus medius muscle. Emergency embolization is performed by installing coil and gelatin. Successful control of bleeding is achieved. To avoid this complication, a complete imaging study is recommended in planning the surgery and to avoid multiple repositioning of the guide or screw. Arterial injury should be suspected in case of increasing pain despite analgesia, functional impairment or neurological deficit and the angiographic study and resolution by selective embolization of the bleeding vessels must be performed.

17.
Oper Neurosurg (Hagerstown) ; 20(3): 282-288, 2021 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-33372208

RESUMO

BACKGROUND: Intraoperative injury during endoscopic endonasal surgery of the carotid artery has been previously described in the literature. However, the accidental damage of the basilar artery in such scenario is not defined. OBJECTIVE: To define the protocol of action for massive bleeding from an artery in the posterior fossa. METHODS: The reported patient was diagnosed with a partially calcified clival chordoma featured by a huge intradural component. An endoscopic endonasal transpterygoid transclival approach was selected for the treatment of this tumor. During the surgical procedure, the basilar artery injury was injured, causing intense bleeding. We present and discuss the surgical maneuvers that could save a patient's life after this dramatic complication. RESULTS: Different techniques were performed in order to control the massive bleeding, including injection of hemotastic matrix with thrombin (Floseal©), bipolar coagulation, and vessel reconstruction by means of a vascular clip. Finally, an autologous muscle graft reinforced with an overlying fibrin sealant patch (Tachosil©) was chosen and was an effective technique. Afterwards, the patient was treated with a flow diverter device to occlude an iatrogenic pseudoaneurysm. A monoplegia of the right upper limb was the only remarkable sequel 6 mo after surgery. CONCLUSION: The muscle graft together with the coordinated action with interventional neuroradiology for the reconstruction of the vessel are possibly the best options to try to preserve the neurological function. In such a scenario, the assumption of potential ischemic events prevails over the intraoperative death of the patient.


Assuntos
Cordoma , Neoplasias da Base do Crânio , Artéria Basilar/diagnóstico por imagem , Artéria Basilar/cirurgia , Endoscopia , Humanos , Instrumentos Cirúrgicos
18.
Am Surg ; 87(5): 747-752, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33169619

RESUMO

BACKGROUND: A national analysis of clavicle fractures is lacking and the risk of concomitant axillosubclavian vessel injury (ASVI) in patients with clavicle fractures is unknown. A minority of patients may have a combined brachial plexus injury (BPI). We sought to describe risk factors for concomitant ASVI in patients with a clavicle fracture; hypothesizing patients with combined clavicle fracture and BPI has a higher risk of ASVI. METHODS: The Trauma Quality Improvement Program (2010-2016) was queried for blunt trauma patients with a clavicle fracture. A multivariable logistic regression model was used to determine risk factors for ASVI. A subset analysis on patients with isolated clavicle fractures was additionally performed. RESULTS: From 59 198 patients with clavicle fractures, 341 (.6%) had concomitant ASVI. Compared to patients without ASVI, patients with ASVI had a higher median injury severity score (24 vs. 17, P < .001) and rates of pulmonary contusions (43.4% vs. 37.7%, P = .029) and BPI (18.2% vs. .4%, P < .001). After controlling for associated chest wall injuries and humerus fracture, the BPI odds ratio (OR 49.17, 35.59-67.92, P < .001) was independently associated with risk for ASVI. In a subset analysis of isolated clavicle fractures, BPI remained associated with risk of ASVI (OR 60.01, confidence intervals 25.29-142.39, P < .001). CONCLUSION: The rate of concomitant ASVI in patients with a clavicle fracture is <1%. Patients presenting with a clavicle fracture had a high rate of injuries including pulmonary contusion. Patients with findings suggestive of underlying BPI had a nearly 50 times increased associated risk of ASVI. Thus, a detailed physical exam in this setting including brachial-brachial index appears warranted.


Assuntos
Plexo Braquial/lesões , Clavícula/lesões , Fraturas Ósseas/complicações , Traumatismos dos Nervos Periféricos/etiologia , Lesões do Sistema Vascular/etiologia , Ferimentos não Penetrantes/complicações , Adulto , Idoso , Idoso de 80 Anos ou mais , Artéria Axilar/lesões , Veia Axilar/lesões , Feminino , Fraturas Ósseas/epidemiologia , Humanos , Incidência , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Traumatismos dos Nervos Periféricos/epidemiologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Artéria Subclávia/lesões , Veia Subclávia/lesões , Lesões do Sistema Vascular/epidemiologia , Ferimentos não Penetrantes/epidemiologia
19.
Vasc Endovascular Surg ; 55(2): 192-195, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32909900

RESUMO

Lower extremity vascular injuries following trauma are rare events that require prompt identification and management in order to prevent ischemia and limb loss. Endovascular approaches, rather than traditional open procedures, are increasingly used to treat a wide range of vascular disease. The use of endovascular repair for revascularization in the trauma setting is not routine but may provide an appealing alternative in select trauma patients and injuries. We present a case of successful endovascular repair with stent grafting of a superficial femoral artery intimal injury following a femur fracture in a 35-year-old morbidly obese female and review the current literature regarding the use of endovascular therapy in the trauma setting.


Assuntos
Acidentes de Trânsito , Angioplastia com Balão/instrumentação , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Artéria Femoral/cirurgia , Fraturas do Fêmur/etiologia , Obesidade Mórbida/complicações , Stents , Lesões do Sistema Vascular/cirurgia , Ferimentos não Penetrantes/cirurgia , Adulto , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/lesões , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Humanos , Obesidade Mórbida/diagnóstico , Resultado do Tratamento , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/etiologia , Ferimentos não Penetrantes/diagnóstico por imagem , Ferimentos não Penetrantes/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...