1.
Adv Mater ; 35(1): e2206764, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36314392

RESUMO

Light manipulation strategies of nature have fascinated humans for centuries. In particular, structural colors are of considerable interest due to their ability to control the interaction between light and matter. Here, wrinkled photonic crystal papers (PCPs) are fabricated to demonstrate the consistent reflection of colors regardless of viewing angles. The nanoscale molecular self-assembly of a cholesteric liquid crystal (CLC) with a microscale corrugated surface is combined. Fully polymerizable CLC paints are uniaxially coated onto a wrinkled interpenetrating polymer network (IPN) substrate. Photopolymerization of the helicoidal nanostructures results in a flexible and free-standing PCP. The facile method of fabricating the wrinkled PCPs provides a scalable route for the development of novel chirophotonic materials with precisely controlled helical pitch and curvature dimensions. The reflection notch position of the flat PCP shifts to a lower wavelength when the viewing angle increased, while the selective reflection wavelength of wrinkled PCP is remained consistent regardless of viewing angles. The optical reflection of the 1D stripe-wrinkled PCP is dependent on the wrinkle direction. PCPs with different corrugated directions can be patterned to reduce the angular-dependent optical reflection of wrinkles. Furthermore, 2D wavy-wrinkled PCP is successfully developed that exhibit directionally independent reflection of color.

2.
Echo Res Pract ; 6(4): 105-114, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31729209

RESUMO

A technology based on velocity ratio indices is described for application in the myocardium. Angle-independent Doppler indices, such as the pulsatility index, which employ velocity ratios, can be measured even if the ultrasound beam vector at the moving target and the motion vector are not in a known plane. The unknown plane situation is often encountered when an ultrasound beam interrogates sites in the myocardium. The velocities employed in an index calculation must be close to the same or opposite directions. The Doppler velocity ratio indices are independent of angle in 3D space as are ratio indices based on 1D strain and 1D speckle tracking. Angle-independent results with spectral Doppler methods are discussed. Possible future imaging techniques based on velocity ratios are presented. By using indices that involve ratios, several other sources of error cancel in addition to that of angular dependence for example errors due to less than optimum gain settings and beam distortion. This makes the indices reliable as research or clinical tools. Ratio techniques can be readily implemented with current commercial blood flow pulsed wave duplex Doppler equipment or with pulsed wave tissue Doppler equipment. In 70 patients where the quality of the real-time B-mode looked suitable for the Doppler velocity ratio technique, there was only one case where clear spectra could not be obtained for both the LV wall and the septum. A reproducibility study of spectra from the septum of the heart shows a 12% difference in velocity ratios in the repeat measurements.

3.
Ultrasound Med Biol ; 43(10): 2256-2268, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28778420

RESUMO

Electromechanical wave imaging (EWI) is an ultrasound-based technique that can non-invasively map the transmural electromechanical activation in all four cardiac chambers in vivo. The objective of this study was to determine the reproducibility and angle independence of EWI for the assessment of electromechanical activation during normal sinus rhythm (NSR) in healthy humans. Acquisitions were performed transthoracically at 2000 frames/s on seven healthy human hearts in parasternal long-axis, apical four- and two-chamber views. EWI data was collected twice successively in each view in all subjects, while four successive acquisitions were obtained in one case. Activation maps were generated and compared (i) within the same acquisition across consecutive cardiac cycles; (ii) within same view across successive acquisitions; and (iii) within equivalent left-ventricular regions across different views. EWI was capable of characterizing electromechanical activation during NSR and of reliably obtaining similar patterns of activation. For consecutive heart cycles, the average 2-D correlation coefficient between the two isochrones across the seven subjects was 0.9893, with a mean average activation time fluctuation in LV wall segments across acquisitions of 6.19%. A mean activation time variability of 12% was obtained across different views with a measurement bias of only 3.2 ms. These findings indicate that EWI can map the electromechanical activation during NSR in human hearts in transthoracic echocardiography in vivo and results in reproducible and angle-independent activation maps.