Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 348
Filtrar
1.
Bioanalysis ; : 1-12, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38940371

RESUMO

Aim: Serotype-specific assays detecting pneumococcal polysaccharides in bodily fluids are needed to understand the pneumococcal serotype distribution in non-bacteremic pneumonia. Methods: We developed a urine antigen detection assay and using urine samples from adult outpatients without pneumonia developed positivity cutoffs for both a previously published 15-valent and the new 21-valent assay. Clinical sensitivity was confirmed with samples from patients with invasive pneumococcal disease. Results: Total assay precision ranged from 7.6 to 17.8% coefficient of variation while accuracy ranged between 80 and 150% recovery, except for three serotypes where recoveries ranged from 32 to 60%. Clinical sensitivity was 86.4% and specificity was 96.5% across all 30 serotypes. Conclusion: The assay could potentially assess serotype-distribution in non-infected and infected participants with pneumococcal disease.


[Box: see text].

2.
Am J Vet Res ; : 1-5, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38942062

RESUMO

OBJECTIVE: To improve the current recommendations for the diagnosis of canine heartworm (Dirofilaria immitis) disease. ANIMALS: Blood samples collected from 35 shelter dogs in the Republic of Korea. METHODS: Samples were tested for the presence of microfilaria using the modified Knott (MK) test and D immitis DNA using species-specific loop-mediated isothermal amplification (LAMP) PCR. The blood samples were additionally assessed for the presence of heartworm antigens using the Antigen Rapid Canine Heartworm AG Test Kit 2.0 (Bionote Co). The performance of the MK test and LAMP PCR was assessed through statistical analysis, with a paired McNemar test utilized for comparison. RESULTS: The heartworm antigen was detected in 28.5% of the subjects. Of the 10 positive animals, the MK test detected microfilaria in 4 of 35 (11.4%) animals, and LAMP PCR detected D immitis DNA in 6 of 35 (17.1%). The results of this study indicate that the LAMP PCR showed more positive results in samples compared to the conventional MK test. CLINICAL RELEVANCE: The D immitis-specific LAMP PCR assay has the potential to function as an alternative to current detection methods. It could complement the existing antigen detection tests in diagnosing canine heartworm infections.

3.
Micromachines (Basel) ; 15(5)2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38793154

RESUMO

This paper presents a biosensor based on the resonant optical tunneling effect (ROTE) for detecting a carcinoembryonic antigen (CEA). In this design, sensing is accomplished through the interaction of the evanescent wave with the CEA immobilized on the sensor's surface. When CEA binds to the anti-CEA, it alters the effective refractive index (RI) on the sensor's surface, leading to shifts in wavelength. This shift can be identified through the cascade coupling of the FP cavity and ROTE cavity in the same mode. Experimental results further show that the shift in resonance wavelength increases with the concentration of CEA. The biosensor responded linearly to CEA concentrations ranging from 1 to 5 ng/mL with a limit of detection (LOD) of 0.5 ng/mL and a total Q factor of 9500. This research introduces a new avenue for identifying biomolecules and cancer biomarkers, which are crucial for early cancer detection.

4.
Anal Sci ; 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38758251

RESUMO

So far, the 2019 novel coronavirus (COVID-19) is spreading widely worldwide. The early diagnosis of infection by the severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) is essential to provide timely treatment and prevent its further spread. Lateral flow assays (LFAs) have the advantages of rapid detection, simple operation, low cost, ease of mass production, and no need for special devices and professional operators, which make them suitable for self-testing at home. This review focuses on the early diagnosis of SARS-CoV-2 infection based on optical LFAs including colorimetric, fluorescent (FL), chemiluminescent (CL), and surface-enhanced Raman scattering (SERS) LFAs for the detection of SARS-CoV-2 antigens and nucleic acids. The types of recognition components, detection modes used for antigen detection, labels employed in different optical LFAs, and strategies to improve the detection sensitivity of LFAs were reviewed. Meanwhile, LFAs coupled with different nucleic acid amplification techniques and CRISPR-Cas systems for the detection of SARS-CoV-2 nucleic acids were summarized. We hope this review provides research mentalities for developing highly sensitive LFAs that can be used in home self-testing for the early diagnosis of SARS-CoV-2 infection.

5.
Viruses ; 16(5)2024 05 16.
Artigo em Inglês | MEDLINE | ID: mdl-38793674

RESUMO

The Nipah virus (NiV) and the Hendra virus (HeV) are highly pathogenic zoonotic diseases that can cause fatal infections in humans and animals. Early detection is critical for the control of NiV and HeV infections. We present the development of two antigen-detection ELISAs (AgELISAs) using the henipavirus-receptor EphrinB2 and monoclonal antibodies (mAbs) to detect NiV and HeV. The NiV AgELISA detected only NiV, whereas the NiV/HeV AgELISA detected both NiV and HeV. The diagnostic specificities of the NiV AgELISA and the NiV/HeV AgELISA were 100% and 97.8%, respectively. Both assays were specific for henipaviruses and showed no cross-reactivity with other viruses. The AgELISAs detected NiV antigen in experimental pig nasal wash samples taken at 4 days post-infection. With the combination of both AgELISAs, NiV can be differentiated from HeV. Complementing other henipavirus detection methods, these two newly developed AgELISAs can rapidly detect NiV and HeV in a large number of samples and are suitable for use in remote areas where other tests are not available.


Assuntos
Anticorpos Monoclonais , Anticorpos Antivirais , Ensaio de Imunoadsorção Enzimática , Efrina-B2 , Vírus Hendra , Infecções por Henipavirus , Vírus Nipah , Vírus Hendra/imunologia , Animais , Vírus Nipah/imunologia , Anticorpos Monoclonais/imunologia , Ensaio de Imunoadsorção Enzimática/métodos , Efrina-B2/metabolismo , Efrina-B2/imunologia , Infecções por Henipavirus/diagnóstico , Infecções por Henipavirus/virologia , Infecções por Henipavirus/imunologia , Anticorpos Antivirais/imunologia , Suínos , Humanos , Sensibilidade e Especificidade , Receptores Virais/metabolismo , Antígenos Virais/imunologia
6.
Front Microbiol ; 15: 1384991, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38800755

RESUMO

Introduction: Rapid identification of infected individuals through viral RNA or antigen detection followed by effective personal isolation is usually the most effective way to prevent the spread of a newly emerging virus. Large-scale detection involves mass specimen collection and transportation. For biosafety reasons, denaturing viral transport medium has been extensively used during the SARS-CoV-2 pandemic. However, the high concentrations of guanidinium isothiocyanate (GITC) in such media have raised issues around sufficient GITC supply and laboratory safety. Moreover, there is a lack of denaturing transport media compatible with SARS-CoV-2 RNA and antigen detection. Methods: Here, we tested whether supplementing media containing low concentrations of GITC with ammonium sulfate (AS) would affect the throat-swab detection of SARS-CoV-2 or a viral inactivation assay targeting coronavirus and other enveloped and non-enveloped viruses. The effect of adding AS to the media on RNA stability and its compatibility with SARS-CoV-2 antigen detection were also tested. Results and discussion: We found that adding AS to the denaturing transport media reduced the need for high levels of GITC, improved SARS-COV-2 RNA detection without compromising virus inactivation, and enabled the denaturing transport media compatible with SARS-CoV-2 antigen detection.

7.
Artigo em Inglês | MEDLINE | ID: mdl-38689530

RESUMO

Recently, concern has been raised about the spread of human mpox virus, and the demand for rapid detection reagents for mpox virus has increased. This study aims to establish a time-resolved fluorescence immunochromatography (TRFICO) method for qualitative/quantitative detection of mpox virus. A double-antibody sandwich TRFICO method was optimized and established using mpox recombinant fusion antigen and its paired monoclonal antibody. The test performance of the method was evaluated using mpox fusion antigen and control serum, including sensitivity, linearity range, specificity, precision, and reference interval. We successfully established a TRFICO method for qualitative/quantitative detection of mpox antigen, its linearity range 0-100 ng/mL, analytical sensitivity 0.017 ng/mL, and reference intervals greater than 0.045 ng/mL. No cross-reaction was detected with various poxvirus and clinical negative controls, with good specificity. All average recoveries of the intra- and inter-batch ranged from 81.33% to 97.83%, and all CVs were below 10%. Additionally, the TRFICO strips can be stably stored at 37°C for 7 days without significant changes in the fluorescence intensity. This TRFICO method, with high sensitivity, linearity range, specificity, precision, and stability with 16-min detection time, provides a new option for qualitative/quantitative and convenient testing of mpox virus.

8.
Heliyon ; 10(9): e29937, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38694118

RESUMO

Background: WHO recommends the use of COVID-19 antigen rapid diagnostic tests (Ag-RDT) with at least 80 % sensitivity and 97 % specificity. In the era of Omicron variants, we sought to ascertain the performance of the INDICAID™ Ag-RDT compared to real-time PCR (RT-PCR) as the gold standard. Methods: A laboratory-based study was conducted among consenting individuals tested for COVID-19 at the virology laboratory of the Chantal BIYA International Reference Centre, Yaoundé-Cameron. The samples were processed by INDICAID™ Ag-RDT and DaAn Gene real-time PCR according to the manufacturer's instructions, and PCR-results were interpreted as per cycle thresholds (CT). The sensitivity, specificity, positive and negative predictive values (PPV and NVP) of INDICAID™ Ag-RDT were evaluated according to PCR CT-values. Results: A total of 565 nasopharyngeal swabs were collected from participants (median age [IQR]: 40 [31-75]; M/F sex-ratio was 1.2 and 380 were vaccinated). Following PCR, overall COVID-19 positivity was 5.66 %. For CT < 37, INDICAID™ Ag-RDT sensitivity was 21.9 % (95%CI: [8.3-39.9]), specificity 100 % (95%CI: [99.3-100]); PPV 100 % (95%CI: [59.0-100]), NPV 95.5 % (95%CI: [93.4-97.1]) and kappa = 0.34 (95%CI: [0.19-0.35]). For CT < 25, sensitivity was 100 % (95%CI: [47.8-100.0]), specificity 99.6 % (95%CI: [98.7-99.9]); PPV 94.4 % (95%CI: [51.7-100]), NPV 100 % (95%CI: [99.3-100]) and kappa = 0.83 (95%CI: [0.6-1.0]). COVID-19 sequences generated were all Omicron BA.1 subvariants. Conclusion: For patients infected with high viral loads (CT < 25), INDICAID™ Ag-RDT has high intrinsic (sensitivity and specificity) and extrinsic (predictive values) performances for COVID-19 diagnosis. Due to its simplicity and short turnaround time, INDICAID™ Ag-RDT is, therefore a reliable tool to prevent the spread of COVID-19 at community level in the current era of Omicron subvariants.

9.
Front Med (Lausanne) ; 11: 1352633, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38698781

RESUMO

Background: This study is the extension of the COVAG study. We compared two RATs, the Panbio COVID-19 Ag Rapid Test (Abbott) and the SD Biosensor Q SARS-CoV-2 Rapid Antigen Test (Roche), against RT-PCR on the foil of new variants. Methods: We included 888 all-comers at a diagnostic center between October 20, 2021, and March 18, 2022. RT-PCR-positive samples with a Ct value ≤32 were examined for SARS-CoV-2 variants. Findings: The sensitivity of the Abbott-RAT and Roche-RAT were 65 and 67%, respectively. For both RATs, lower Ct values were significantly correlated with higher sensitivity. For samples with Ct values ≤25, the sensitivities of the Roche-RAT and of the Abbott-RAT were 96 and 95%, for Ct values 25-30 both were 19%, and for Ct values ≥30 they were 6 and 2%, respectively. The RATs had substantially higher sensitivities in symptomatic than asymptomatic participants (76, 77%, vs. 29, 31%, for Abbott-RAT, Roche-RAT, respectively) and in participants referred to testing by their primary care physician (84, 85%) compared to participants who sought testing due to referral by the health department (55, 58%) or a warning by the Corona-Warn-App (49, 49%). In persons with self-reported previous COVID-19 sensitivities were markedly lower than in patients without previous COVID-19: 27% vs. 75% for Roche-RAT and 27% vs. 73% for Abbott-RAT. We did not find significant correlation between vaccination status and sensitivity. The Omicron variant was detected with a sensitivity of 94 and 92%, the delta variant with a sensitivity of 80 and 80% for Abbott-RAT and Roche-RAT, respectively. This difference is attributable to the lower Ct values of the Omicron samples compared to the Delta samples. When adjusted for the Ct value, a multivariate logistic regression did not show a significant difference between Omicron and Delta. In terms of sensitivity, we found no significant difference between the wild-type and the Omicron and Delta variants, but a significantly lower sensitivity to the alpha variant compared to the other variants.The specificities were > 99% overall.

10.
J Pathol Clin Res ; 10(3): e12373, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38572528

RESUMO

Diagnosing extrapulmonary tuberculosis (EPTB) is challenging. Immunohistochemistry or immunocytochemistry has been used to diagnose tuberculosis (TB) by detection of MPT64 antigen from various extrapulmonary specimens and has shown good diagnostic performance in our previous studies. The test can distinguish between disease caused by Mycobacterium tuberculosis (Mtb) complex and nontuberculous mycobacteria and can be applied on formalin-fixed paraffin-embedded tissue. As the antibodies previously used were in limited supply, a new batch of polyclonal antibodies was developed for scale-up and evaluated for the first time in this study. Our aim was to assess the diagnostic accuracy of the MPT64 test with reproduced antibodies in the high burden settings of Pakistan and India. Patients were enrolled prospectively. Samples from suspected sites of infection were collected and subjected to histopathologic and/or cytologic evaluation, routine TB diagnostics, GeneXpert MTB/RIF (Xpert), and the MPT64 antigen detection test. Patients were followed until the end of treatment. Based on a composite reference standard (CRS), 556 patients were categorized as TB cases and 175 as non-TB cases. The MPT64 test performed well on biopsies with a sensitivity and specificity of 94% and 75%, respectively, against a CRS. For cytology samples, the sensitivity was low (36%), whereas the specificity was 81%. Overall, the MPT64 test showed higher sensitivity (73%) than Xpert (38%) and Mtb culture (33%). The test performed equally well in adults and children. We found an additive diagnostic value of the MPT64 test in conjunction with histology and molecular tests, increasing the yield for EPTB. In conclusion, immunochemical staining with MPT64 antibodies improves the diagnosis of EPTB in high burden settings and could be a valuable addition to routine diagnostics.


Assuntos
Mycobacterium tuberculosis , Tuberculose Extrapulmonar , Tuberculose , Adulto , Humanos , Criança , Imuno-Histoquímica , Tuberculose/diagnóstico , Tuberculose/microbiologia , Antígenos de Bactérias
11.
Pathogens ; 13(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38668248

RESUMO

Despite several decades of mass drug administration and elimination-related activities, human onchocerciasis still represents a major parasitic threat in endemic regions. Among the challenges encountered by the elimination program is the lack of a suitable diagnostic tool that is accurate and non-invasive. Currently used methods are either invasive or not suitable for monitoring large numbers of patients. Herein, we describe the identification and characterization of Onchocerca volvulus heat shock protein 70 (OvHSP70) as a novel diagnostic biomarker for human onchocerciasis, which can directly be detected in urine samples of infected patients. This nematode-specific antigen was identified through LC-MS after differential SDS-PAGE using urine-derived protein extracts from O. volvulus-infected patients in Cameroon. Polyclonal antibodies generated in rabbits after cloning and expression of OvHSP70 in Escherichia coli reliably differentiated between urine samples from infected- and uninfected patients in a hypoendemic area of human onchocerciasis. These results provide an excellent basis for further development of a non-invasive and scalable diagnostic assay for human onchocerciasis using urine samples. Such a urine-based diagnostic assay will be of major importance for the elimination program of human onchcerciasis in endemic countries.

12.
Curr Med Chem ; 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38468515

RESUMO

The burden of increasing cancer incidence among the population, and, in particular, of prostate cancer in men living in highly developed countries, brings with it, on one hand, the need for new devices that allow a faster and earlier diagnosis, ideally in a non-invasive way and with low consumption of expensive reagents, and on the other the need for the assessment of new in vitro models that allow a more reliable assessment of cancer features, including its microenvironment and sensibility to different drugs. At the crossroads of these features, microfluidic devices are found. These, taking advantage of the chemical-physical properties of cells and human samples, have demonstrated great sensitivity and sensibility at an on-chip scale. Many fields of biomedical sciences have tried to exploit all their potentialities: from the detection of antigens in the early phases of the disease (when they are very low concentrated, but the treatment is more effective) to isolation and characterization of circulating tumor cells. However, the development of in vitro 3D models to better assess and comprehend the fundamental dynamics of tumor microenvironment and metastasis using 3D bioprinting techniques. The aim of the present review is to describe the potential of these two different cutting-edge technologies for the detection and treatment of prostate cancer, in the perspective of a possible future combination of them that allows scientists to fill the gaps present in the field to improve patient care and treatment.

13.
Clin Pediatr (Phila) ; : 99228241237908, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38469805

RESUMO

The primary objective was to evaluate Group A streptococcal (GAS) tests performed with a Modified Centor Criteria (MCC) Score < 3 at Urgent Care Clinics (UCC). Secondary objectives included evaluating the MCC sensitivity and specificity, antibiotics prescribed with an MCC score < 3, and association between palatal petechiae and GAS pharyngitis infections. This was a retrospective review from July 1, 2018, to June 30, 2019, of Rapid Antigen Detection Tests (RADTs) on patients with ICD codes associated with pharyngitis. Fifteen hundred patient charts were reviewed. The majority of MCC scores were < 3 at 60.0% (878/1464). Sensitivity of GAS testing (RADT/culture) slightly increased for MCC scores ≥ 3 and was better than the specificity of those scores. In comparison, MCC scores < 3, showed better specificity compared to sensitivity. Over 50% of RADTs performed were inappropriate per clinical guidelines. MCC score < 3 had higher rates of negative test results.

14.
Viruses ; 16(3)2024 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-38543759

RESUMO

Hepatitis E virus (HEV) causes acute hepatitis in humans, which can progress to chronicity in immunosuppressed individuals. Almost all reported HEV infections are caused by Paslahepevirus balayani genotypes 1-4. The structural ORF2 protein is the major antigen detected in the blood of HEV-infected individuals. ELISA assays to detect IgM antibodies to HEV are the first-line diagnostic tests; however, they showed variable performance with frequently discordant results. A qualitative HEV antigen (ORF2) ELISA is currently available for research use. Here, we report a novel quantitative sandwich ELISA to measure HEV ORF2 protein in 3 matrix types. An optimal pair of capture and detection antibodies was selected among 12 unique combinations tested. A sandwich ELISA protocol was developed using these mAbs and biotin-streptavidin technology. The protocol was further optimized to quantify ORF2 antigen in different matrices by interpolating from a standard curve with a linear range of 3.17 to 50.8 femtomoles/mL. Using this method, ORF2 protein was detected in the cell culture medium of Huh7 cells as early as 2-3 days after transfection with HEV genome RNA and in a medium of human hepatocytes infected with HEV. ORF2 antigen was readily detected in the first 2 weeks post-HEV infection in gerbil sera. In immunosuppressed gerbils, ORF2 was detected up to 6 weeks, and the levels were significantly higher between 3 and 6 weeks post-infection. HEV ORF2 antigen levels showed a strong positive correlation with HEV RNA levels in both cell culture medium and gerbil sera. Our novel sandwich ELISA detected at least 7.3 femtomoles/mL ORF2 protein in human plasma spiked with cell culture propagated HEV and detected ORF2 protein in human plasma samples that tested positive for HEV RNA but negative for anti-HEV antibodies. Further, the assay was nonreactive, with negative human plasma, and HBV or HCV-positive human plasma demonstrating specificity. Overall, our ORF2 antigen ELISA will be useful for quantifying ORF2 antigen in cell culture medium, gerbil serum, and human plasma. Further studies are warranted to evaluate its utility in HEV clinical diagnosis.


Assuntos
Vírus da Hepatite E , Hepatite E , Animais , Humanos , Vírus da Hepatite E/genética , Gerbillinae , Ensaio de Imunoadsorção Enzimática/métodos , Anticorpos Anti-Hepatite , RNA/metabolismo
15.
Microbes Infect ; 26(4): 105332, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38537770

RESUMO

BACKGROUND: Little knowledge of antigen existence in the pulmonary tuberculosis (PTB) patient serum impeded its development in antigen detection technology, despite its considerable potential. METHODS: Human ligand proteins and their adsorbent Mycobacterium tuberculosis (M.tb) proteins in the serum of PTB patients were identified using human protein chip (HuProt™) and LC-MS/MS, successively. The monoclonal antibody of ligand proteins, C5orf24, and polyclonal antibody of 9 M.tb proteins were prepared on mice and rabbits which were used to develop a novel enzyme-linked ligand-sorbent assay (ELLSA). The 412 volunteers were divided into the PTB group (n = 250) and the healthy control (n = 162). The PTB group was further divided into ATB (n = 131), LTBI (n = 18), Clinical diagnosis (n = 18), and Suspected (n = 73). All samples were tested by ELLSA to evaluate the diagnostic performance of ELLSA in PTB patients. RESULTS: Nine ligand proteins specific to PTB patients were identified on chips, with Chromosome 5 Open Reading Frame 24 (C5orf24) and kinocilin (KNCN) showing significantly higher signals. Proteomic analysis of the C5orf24-and KNCN-adsorbent protein complexes revealed 10 and 10 of the M.tb proteins, respectively. According to the composition reference of standard, the ELLSA based on C5orf24 ligand demonstrated a higher sensitivity of 69.6% and specificity of 90.18% in ATB patients and had a sensitivity of 64.22% in bacterial negative pulmonary tuberculosis, whereas the sensitivity of MGIT 960 and Xpert M.tb/RIF were 0%, respectively. CONCLUSIONS: M.tb proteins in serum can be enriched by ligand proteins and detected by ELLSA which proved to have excellent diagnostic performance for PTB.


Assuntos
Antígenos de Bactérias , Mycobacterium tuberculosis , Tuberculose Pulmonar , Tuberculose Pulmonar/diagnóstico , Tuberculose Pulmonar/sangue , Humanos , Estudos Retrospectivos , Mycobacterium tuberculosis/imunologia , Feminino , Adulto , Estudos Transversais , Animais , Pessoa de Meia-Idade , Antígenos de Bactérias/imunologia , Masculino , Coelhos , Camundongos , Sensibilidade e Especificidade , Ensaio de Imunoadsorção Enzimática/métodos , Proteínas de Bactérias/imunologia , Proteínas de Bactérias/genética , Ligantes , Adulto Jovem , Proteômica/métodos , Idoso , Espectrometria de Massas em Tandem , Cromatografia Líquida
16.
Vaccines (Basel) ; 12(3)2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38543941

RESUMO

African swine fever (ASF) is a contagious disease of wild boar and domestic pigs notifiable to the World Organisation for Animal Health due to its high socio-economic impact. ASF is caused by the complex ASF virus (ASFV), and it can present different clinical manifestations that can be confused with other diseases; for this reason, laboratory testing is necessary for the proper diagnosis of clinically suspected animals. Despite the efforts put into it over decades, no treatment or safe vaccine is globally available, and disease control is based on early diagnosis and the implementation of strict biosecurity measures. In this context, rapid tests have the potential to accelerate and facilitate the identification of infected animals by giving fast on-site results. In this work, we improved the available point-of-care assays for the diagnosis of the disease by the development of a more specific antigen test and a more sensitive antibody test. This antibody detection test allowed for the earlier detection of infected animals than two commercial indirect ELISAs (statistically significant). Moreover, we developed a combined dual rapid test, unifying, in the same cassette, an antigen detection strip and an antibody detection strip. In this study, we confirmed that this combo approach is a useful tool for implementing rapid tests in the field since it increases the percentage of positive samples detected, even when PCR turns negative, while maintaining a good specificity.

17.
Children (Basel) ; 11(3)2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38539311

RESUMO

Antibiotic overprescribing is prevalent in pediatric emergency medicine, influenced by clinician-caregiver dynamics and diagnostic uncertainties, and poses substantial risks such as increasing antibacterial resistance, adverse drug reactions, and increased healthcare expenditures. While antimicrobial stewardship programs have proven effective in optimizing antibiotic use within inpatient healthcare settings, their implementation in pediatric emergency medicine presents specific challenges. Existing biomarkers like white blood cell count, C-reactive protein, procalcitonin, and presepsin have limitations in their ability to distinguish (serious) bacterial infections from other etiologies of fever. Furthermore, rapid antigen detection tests and guidelines aimed at guiding antibiotic prescriptions for children have not consistently reduced unnecessary antibiotic use. To improve antibiotic prescribing practices, potential strategies include the utilization of decision support tools, audit and feedback, establishing follow-up procedures, implementing safety netting systems, and delivering comprehensive training and supervision. Notably, host genome signatures have also gained attention for their potential to facilitate rapid and precise diagnoses of inflammatory syndromes. Standardized metrics are crucial for evaluating antimicrobial use within pediatric healthcare settings, enabling the establishment of benchmarks for assessing antibiotic utilization, quality enhancement initiatives, and research endeavors.

18.
Protein Sci ; 33(4): e4916, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38501598

RESUMO

Alongside vaccines and antiviral therapeutics, diagnostic tools are a crucial aid in combating the COVID-19 pandemic caused by the etiological agent SARS-CoV-2. All common assays for infection rely on the detection of viral sub-components, including structural proteins of the virion or fragments of the viral genome. Selective pressure imposed by human intervention of COVID-19 can, however, induce viral mutations that decrease the sensitivity of diagnostic assays based on biomolecular structure, leading to an increase in false-negative results. In comparison, mutations are unlikely to alter the function of viral proteins, and viral machinery is under less selective pressure from vaccines and therapeutics. Accordingly, diagnostic assays that rely on biomolecular function can be more robust than ones that rely on biopolymer structure. Toward this end, we used a split intein to create a circular ribonuclease zymogen that is activated by the SARS-CoV-2 main protease, 3CLpro . Zymogen activation by 3CLpro leads to a >300-fold increase in ribonucleolytic activity, which can be detected with a highly sensitive fluorogenic substrate. This coupled assay can detect low nanomolar concentrations of 3CLpro within a timeframe comparable to that of common antigen-detection protocols. More generally, the concept of detecting a protease by activating a ribonuclease could be the basis of diagnostic tools for other indications.


Assuntos
COVID-19 , Proteases 3C de Coronavírus , Vacinas , Humanos , SARS-CoV-2/genética , SARS-CoV-2/metabolismo , Precursores Enzimáticos/genética , Ribonucleases , Pandemias , Proteínas não Estruturais Virais/química , Inibidores de Proteases/química , Antivirais/química
19.
Anal Bioanal Chem ; 416(8): 1961-1970, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38349532

RESUMO

Controlling the spread of pathogen requires an efficient and accurate diagnosis. Compared with nucleic acid and antibody detection, antigen assays are more convenient to meet clinical diagnostic needs. However, antigen detection is often difficult to achieve high sensitivity in a limited time. In this work, a novel aptasensing method was designed for the purpose of SARS-CoV-2 antigen detection, using a dumbbell padlock probe-mediated circle-to-circle amplification (C2CA) approach. A sandwich complex of antibody-antigen-aptamer is first formed on the magnetic beads. Afterwards, the signal is amplified by a C2CA reaction involving two tandem rolling circle amplifications. Without special instruments or nanomaterials, a detection limit of 575 fg/mL for S1 protein can be achieved in less than 2 h. In the case of the spike pseudovirus SARS-CoV-2 in artificial saliva, the detection limit is 272 TU/µL, which is much lower than average viral load in patients. Therefore, our method provides a timely, efficient and accurate approach for the clinical diagnosis of SARS-CoV-2. It also opens up the application of C2CA in aptamer sensing and antigen detection.


Assuntos
Técnicas Biossensoriais , COVID-19 , Técnicas Biossensoriais/métodos , COVID-19/diagnóstico , Técnicas de Amplificação de Ácido Nucleico/métodos , SARS-CoV-2
20.
J Fungi (Basel) ; 10(2)2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38392761

RESUMO

Immunoassays for cell wall mannans that are excreted into serum and urine have been used as an aid in the diagnosis of many disseminated fungal infections, including coccidioidomycosis. Antigen-detection immunoassays are critically dependent on the detection of an analyte, such as mannan, by antibodies that are specific to the analyte. The goal of this study was to evaluate the extent of cross-reactivity of polyclonal antibodies raised against Coccidioides spp. Analysis of antigenic relatedness between mannans from C. posadasii and C. immitis spherules and mycelia showed complete relatedness when evaluated by the method of Archetti and Horsfall, which was originally used to study the antigenic relationships between Influenzae virus isolates. In a further effort to validate the suitability of the antigenic relatedness calculation methodology for polysaccharide antigens, we also applied the method of Archetti and Horsfall to published results that had previously identified the major capsular serotypes of Cryptococcus species. The results of this analysis showed that Archetti and Horsfall's antigenic relatedness calculation correctly identified the major cryptococcal serotypes. Together, these results suggest that the method is applicable to polysaccharide antigens, and that immunoassays that detect Coccidioides mannans are likely to have good reactivity across Coccidioides species (inclusivity) due to the species' high level of antigenic relatedness.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...